<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Low oil circuit breaker</title>
       <link>http://www.91way.com</link>
       <description>Low oil circuit breaker</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:12:17</pubDate>
       <item>
           <title>[Low oil circuit breaker]SW2-63 High voltage low oil circuit breaker </title>
           <link>http://www.91way.com/info_en/19335.html</link>
           <author></author>
           <guid></guid>
           <category>Low oil circuit breaker</category>
           <pubDate>2026-6-10 20:55:09</pubDate>
           <comments></comments>
           <description>The SW2 series high-voltage low oil circuit breaker is a three-phase AC 50Hz outdoor high-voltage power equipment, mainly used for control and protection of transmission lines, and can also be used as a contact circuit breaker. This series of circuit breakers is based on a 63kV arc extinguishing unit, using a double tube structure arc extinguishing chamber and a longitudinal and transverse arc extinguishing principle. Form a single or multiple break block structure according to different voltage levels. SW2-63 type single column single fracture surface per phase. SW2-110 type single column double fracture surface for each phase. SW2-220 type double column with four fracture surfaces per phase. The SW2 series low oil circuit breaker is developed based on SW2-60 and SW6-220 through a series of significant improvements. This product has the characteristics of strong series, high breaking current, simple structure, reliable action, and easy installation and debugging&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=18 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;40%&quot;&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;26%&quot;&gt;
&lt;DIV align=center&gt;Example diagram&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SW2-63II/1600-25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=16&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Maximum operating voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-two point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=16&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Thermal stable current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Thermal stability time&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Dynamic stability current (peak value)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Rated short-circuit closing current (peak)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;When closing (minimum, maximum, rated operating voltage)&lt;/TD&gt;
&lt;TD&gt;KV&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Minimum operating voltage&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Rated operating voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Maximum operating voltage&lt;/TD&gt;
&lt;TD&gt;KV&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0-0.5 S-CO-180 S-CO&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Net weight of circuit breaker&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;oil weight&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201206/20120625064302566.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 510px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Appearance and installation dimensions of SW2-63 high-voltage low oil circuit breaker&quot; src=&quot;/upload2012/201206/20120625064302566.jpg&quot; width=680 height=510&gt;&lt;/A&gt;&lt;BR&gt;SW2-63 High Voltage Low Oil Circuit Breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low oil circuit breaker]SW2,SW4,SW6 Series Outdoor High Voltage Low Oil Circuit Breaker </title>
           <link>http://www.91way.com/info_en/3909.html</link>
           <author></author>
           <guid></guid>
           <category>Low oil circuit breaker</category>
           <pubDate>2026-6-10 20:55:00</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200806/20086784612932.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 271px; WIDTH: 261px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of SW2, SW4, SW6 series outdoor high-voltage low oil circuit breakers&quot; src=&quot;/uploadfiles/200806/20086784612932.jpg&quot; width=261 height=271&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SW2, SW4, SW6 series outdoor high-voltage low oil circuit breakers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low oil circuit breaker]SN10 High Voltage Low Oil Circuit Breaker </title>
           <link>http://www.91way.com/info_en/2874.html</link>
           <author></author>
           <guid></guid>
           <category>Low oil circuit breaker</category>
           <pubDate>2026-6-10 20:54:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The SN10-10 (C) and SN10-35 (KV) series indoor high-voltage low oil circuit breakers are indoor switchgear in slurry filled 50Hz three-phase AC systems, which can be used for protection and control in industrial and mining enterprises, power plants, and substations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of SN10 high-voltage low oil circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE id=table1 style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;serial number&lt;/TD&gt;
&lt;TD rowSpan=2 width=116 colSpan=4 align=center&gt;Name&lt;/TD&gt;
&lt;TD rowSpan=2 width=37 align=center&gt;unit&lt;/TD&gt;
&lt;TD height=24 width=497 colSpan=6 align=center&gt;Numerical value&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=89 align=center&gt;SN10-10 I£¨C£©/630-16&lt;/TD&gt;
&lt;TD width=89 align=center&gt;SN10-10 I/&lt;BR&gt;1000-16&lt;/TD&gt;
&lt;TD width=91 align=center&gt;SN10-10 II&lt;BR&gt;£¨C£©1000-31.5&lt;/TD&gt;
&lt;TD width=92 align=center&gt;SN10-10 III&lt;BR&gt;(C)/1250-40&lt;/TD&gt;
&lt;TD width=93 align=center&gt;SN10-10 III&lt;BR&gt;(C)/2000-40&lt;/TD&gt;
&lt;TD width=89 align=center&gt;SN10-10 III&lt;BR&gt;(C)/3000-40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;one&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD height=88 rowSpan=4 width=37 align=center&gt;KV&lt;/TD&gt;
&lt;TD width=496 colSpan=6 align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;two&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;maximum voltage&lt;/TD&gt;
&lt;TD width=496 colSpan=6 align=center&gt;eleven point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;three&lt;/TD&gt;
&lt;TD rowSpan=2 width=132 colSpan=2 align=center&gt;Rated insulation level&lt;/TD&gt;
&lt;TD width=79 colSpan=2 align=center&gt;Lightning impulse withstand voltage (full wave)&lt;/TD&gt;
&lt;TD width=496 colSpan=6 align=center&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=79 colSpan=2 align=center&gt;Power frequency withstand voltage for 1 minute&lt;/TD&gt;
&lt;TD width=496 colSpan=6 align=center&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;four&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;rated current&lt;/TD&gt;
&lt;TD width=37 align=center&gt;A&lt;/TD&gt;
&lt;TD align=center&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD width=89 align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=91 align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=92 align=center&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD width=93 align=center&gt;two thousand&lt;/TD&gt;
&lt;TD width=89 align=center&gt;three thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;five&lt;/TD&gt;
&lt;TD rowSpan=2 width=132 colSpan=2 align=center&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD rowSpan=2 width=79 colSpan=2 align=center&gt;6KV&lt;BR&gt;10KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=37 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;twenty&lt;/TD&gt;
&lt;TD rowSpan=2 width=91 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD height=65 rowSpan=3 width=302 colSpan=3 align=center&gt;40 (Fen-180S-HeFen-180S-HeFen)&lt;BR&gt;&lt;BR&gt;31.5 (Fen-0.5S-180S-Fen)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=162 colSpan=2 align=center&gt;sixteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=21 width=39 align=center&gt;six&lt;/TD&gt;
&lt;TD height=21 width=116 colSpan=4 align=center&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD height=18 width=37 align=center&gt;&lt;/TD&gt;
&lt;TD height=21 width=244 colSpan=3 align=center&gt;Fen-0.5S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;seven&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;Rated short-circuit closing current (peak)&lt;/TD&gt;
&lt;TD rowSpan=3 width=37 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;40;50*&lt;/TD&gt;
&lt;TD width=91 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=282 colSpan=3 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;eight&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;Rated peak closing current&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;40;50*&lt;/TD&gt;
&lt;TD width=91 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=282 colSpan=3 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;nine&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;Rated short-circuit withstand current&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;16;20*&lt;/TD&gt;
&lt;TD width=91 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=282 colSpan=3 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 align=center&gt;ten&lt;/TD&gt;
&lt;TD width=116 colSpan=4 align=center&gt;Rated short-time duration&lt;/TD&gt;
&lt;TD rowSpan=3 width=37 align=center&gt;S&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;four&lt;/TD&gt;
&lt;TD width=175 colSpan=2 align=center&gt;two&lt;/TD&gt;
&lt;TD width=164 colSpan=2 align=center&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;eleven&lt;/TD&gt;
&lt;TD rowSpan=2 width=120 colSpan=2 align=center&gt;closing time&lt;/TD&gt;
&lt;TD rowSpan=2 width=42 align=center&gt;Electromagnetic mechanism&lt;BR&gt;Spring mechanism&lt;/TD&gt;
&lt;TD rowSpan=2 width=43 align=center&gt;not greater than&lt;/TD&gt;
&lt;TD width=178 colSpan=2 align=center&gt;zero point two&lt;/TD&gt;
&lt;TD width=366 colSpan=4 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=178 colSpan=2 align=center&gt;zero point one five&lt;/TD&gt;
&lt;TD width=366 colSpan=4 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=39 align=center&gt;twelve&lt;/TD&gt;
&lt;TD rowSpan=3 width=63 align=center&gt;Opening time&lt;/TD&gt;
&lt;TD width=39 colSpan=2 align=center&gt;When electricity&lt;/TD&gt;
&lt;TD width=43 align=center&gt;minimum&lt;/TD&gt;
&lt;TD height=106 rowSpan=5 width=37 align=center&gt;&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=91 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=296 colSpan=3 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 colSpan=2 align=center&gt;voltage&lt;/TD&gt;
&lt;TD width=43 align=center&gt;rated&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;zero point zero six&lt;/TD&gt;
&lt;TD width=91 align=center&gt;zero point zero six&lt;/TD&gt;
&lt;TD width=296 colSpan=3 align=center&gt;0.07 (main cylinder)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=39 colSpan=2 align=center&gt;Source Force&lt;/TD&gt;
&lt;TD width=43 align=center&gt;highest&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;zero point zero six&lt;/TD&gt;
&lt;TD width=91 align=center&gt;zero point zero three&lt;/TD&gt;
&lt;TD width=296 colSpan=3 align=center&gt;0.07 (main cylinder)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;thirteen&lt;/TD&gt;
&lt;TD rowSpan=2 width=63 align=center&gt;weight&lt;/TD&gt;
&lt;TD rowSpan=2 width=79 colSpan=3 align=center&gt;Circuit breaker body (oil-free) oil (three-phase)&lt;/TD&gt;
&lt;TD width=162 colSpan=2 align=center&gt;one hundred&lt;/TD&gt;
&lt;TD width=91 align=center&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD width=92 align=center&gt;one hundred and forty&lt;/TD&gt;
&lt;TD width=93 align=center&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD width=89 align=center&gt;one hundred and ninety&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=162 colSpan=2 align=center&gt;six&lt;/TD&gt;
&lt;TD width=90 align=center&gt;eight&lt;/TD&gt;
&lt;TD width=91 align=center&gt;nine&lt;/TD&gt;
&lt;TD width=205 colSpan=2 align=center&gt;thirteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39 align=center&gt;fourteen&lt;/TD&gt;
&lt;TD rowSpan=2 width=117 colSpan=2 align=center&gt;Model of the accompanying institution&lt;/TD&gt;
&lt;TD height=25 width=79 colSpan=2 align=center&gt;Electromagnetic mechanism&lt;/TD&gt;
&lt;TD rowSpan=2 width=37 align=center&gt;&lt;/TD&gt;
&lt;TD width=178 colSpan=2 align=center&gt;CD10 I&lt;/TD&gt;
&lt;TD width=181 colSpan=2 align=center&gt;CD10 I&lt;/TD&gt;
&lt;TD width=181 colSpan=2 align=center&gt;CD10 III&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=18 width=79 colSpan=2 align=center&gt;Spring mechanism&lt;/TD&gt;
&lt;TD width=178 colSpan=2 align=center&gt;&lt;/TD&gt;
&lt;TD width=183 colSpan=2 align=center&gt;CT8 I CTB II&lt;/TD&gt;
&lt;TD width=181 colSpan=2 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;&lt;BR&gt;If the rated breaking current is 20KA (below 6KA), the rated short-circuit closing current, rated peak withstand current is 50KA, and rated short-time withstand current is 20KA&lt;BR&gt;&lt;BR&gt;External installation dimensions of SN10 high-voltage low oil circuit breaker&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200711/200711712276804.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 385px; WIDTH: 566px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of SN10 high-voltage low oil circuit breaker&quot; src=&quot;/uploadfiles/200711/200711712276804.jpg&quot; width=566 height=385&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;SN10 type high voltage low oil circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>