<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Multi oil circuit breaker</title>
       <link>http://www.91way.com</link>
       <description>Multi oil circuit breaker</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:12:17</pubDate>
       <item>
           <title>[Multi oil circuit breaker]DW10-10 type column mounted multi oil circuit breaker </title>
           <link>http://www.91way.com/info_en/2873.html</link>
           <author></author>
           <guid></guid>
           <category>Multi oil circuit breaker</category>
           <pubDate>2026-6-10 20:54:11</pubDate>
           <comments></comments>
           <description>The DW10-10 column mounted multi oil circuit breaker is used in a three-phase AC 50Hz power system with a rated voltage of 10KV for load current, overload current, and short-circuit protection.&lt;BR&gt;This product is installed on outdoor poles and operated on the ground with hooks or ropes.&lt;BR&gt;Terms of Use&lt;BR&gt;1. Altitude not exceeding: 4000 meters;&lt;BR&gt;2. The ambient temperature ranges from -30 ¡æ to 40 ¡æ;&lt;BR&gt;3. Places without flammable gases and conductive dust;&lt;BR&gt;4. Places without easily corrosive gases and conductive dust;&lt;BR&gt;Note: The ambient temperature is related to the transformer oil used. When the transformer oil is domestic grade 10 or 45 oil, the minimum operating temperature should not be lower than -45 ¡æ.&lt;BR&gt;&lt;BR&gt;Main technical parameters of DW10-10 column mounted multi oil circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;rated voltage&lt;BR&gt;£¨KV£©&lt;/TD&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;Maximum operating voltage (KV)&lt;/TD&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;Rated current (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;Rated breaking capacity (MVA)&lt;/TD&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;Rated breaking current (KA)&lt;/TD&gt;
&lt;TD width=194 colSpan=2 align=center&gt;Limit passing current&lt;/TD&gt;
&lt;TD rowSpan=2 width=97 align=center&gt;Multiple of tripping device operating current&lt;/TD&gt;
&lt;TD width=194 colSpan=2 align=center&gt;Product weight&lt;/TD&gt;
&lt;TD rowSpan=2 width=98 align=center&gt;Dimensions (mm)&lt;/TD&gt;
&lt;TD rowSpan=2 width=98 align=center&gt;Installation size (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;Effective value KA&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Peak KA&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Without oil KG&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Oil weight KG&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;eleven point five&lt;/TD&gt;
&lt;TD height=31 width=97 align=center&gt;fifty&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;fifty&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;three point one five&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;four point two&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;eight&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;1.2-2&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;ninety-six&lt;/TD&gt;
&lt;TD rowSpan=5 width=97 align=center&gt;thirty-five&lt;/TD&gt;
&lt;TD rowSpan=5 width=98 align=center&gt;760x&lt;BR&gt;510x860&lt;/TD&gt;
&lt;TD rowSpan=5 width=98 align=center&gt;380x260&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;six hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200711/200711712241467.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 269px; WIDTH: 293px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of DW10-10 column mounted multi oil circuit breaker&quot; src=&quot;/uploadfiles/200711/200711712241467.jpg&quot; width=293 height=269&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100601135007850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1050px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of DW10-10 Column mounted Multi oil Circuit Breaker&quot; src=&quot;/upload2010/201006/20100601135007850.jpg&quot; width=680 height=1050&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Multi oil circuit breaker]DW10-10/G Series Outdoor AC High Voltage Multi Oil Circuit Breaker </title>
           <link>http://www.91way.com/info_en/2872.html</link>
           <author></author>
           <guid></guid>
           <category>Multi oil circuit breaker</category>
           <pubDate>2026-6-10 20:54:01</pubDate>
           <comments></comments>
           <description>DW10-10 I, II, III, G type outdoor high-voltage multi oil circuit breakers are three-phase AC 50Hz high-voltage switchgear suitable for urban or rural power systems with a rated voltage of 10KV, used for control and protection of power equipment and power lines. This circuit breaker can reliably switch between load current, overload current, and short-circuit current.&lt;BR&gt;&lt;BR&gt;Main technical parameters of DW10-10/G series outdoor AC high-voltage multi oil circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;Rated voltage (KV)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated current (A)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated short-circuit breaking&lt;BR&gt;Current (KA)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated short-circuit closing&lt;BR&gt;Current (KA)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated peak tolerance&lt;BR&gt;Current (KA)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated short-time tolerance&lt;BR&gt;Current (KA)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;Rated short-term duration&lt;BR&gt;Time (KA)&lt;/TD&gt;
&lt;TD width=98 align=center&gt;Weight (kg)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=97 align=left&gt;ten&lt;/TD&gt;
&lt;TD width=97 align=center&gt;thirty&lt;/TD&gt;
&lt;TD rowSpan=6 width=97 align=center&gt;one point eight&lt;BR&gt;&lt;BR&gt;two point nine&lt;/TD&gt;
&lt;TD rowSpan=6 width=97 align=center&gt;four point five&lt;BR&gt;&lt;BR&gt;seven point four&lt;/TD&gt;
&lt;TD rowSpan=6 width=97 align=center&gt;four point five&lt;BR&gt;&lt;BR&gt;seven point four&lt;/TD&gt;
&lt;TD rowSpan=6 width=97 align=center&gt;one point eight&lt;BR&gt;&lt;BR&gt;two point nine&lt;/TD&gt;
&lt;TD rowSpan=6 width=97 align=center&gt;four&lt;/TD&gt;
&lt;TD rowSpan=6 width=98 align=center&gt;ninety-five&lt;BR&gt;&lt;BR&gt;ninety-six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97 align=center&gt;six hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Structure Introduction&lt;BR&gt;The circuit breaker is a three-phase common box oil immersed mechanism, using plug-in copper tungsten contacts (one piece for Type I static contacts and two pieces for Type II static contacts). The box is equipped with an overcurrent release and a delay device, which can automatically release when the network fails. Oil also serves as an arc extinguishing insulation medium. The manual operating mechanism is installed at the front end of the box and integrated with the switch. The wire passes through the porcelain sleeve fixed on both sides of the box cover and is led out.&lt;BR&gt;DW10-10 I-G type adopts anti type porcelain sleeve and increases the external insulation distance; The box cover and the box body are fully enclosed and connected; The tripping current can be adjusted inside the mechanism cover without opening the box.&lt;BR&gt;&lt;BR&gt;DW10-10/G series outdoor AC high voltage multi oil circuit breaker external installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200711/200711712229845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 167px; WIDTH: 496px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DW10-10/G series outdoor AC high-voltage multi oil circuit breaker appearance and installation dimension diagram&quot; src=&quot;/uploadfiles/200711/200711712229845.jpg&quot; width=496 height=167&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;DW10-10/G series outdoor AC high-voltage multi oil circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Multi oil circuit breaker]DW8-35 High Voltage Multi Oil Circuit Breaker </title>
           <link>http://www.91way.com/info_en/2871.html</link>
           <author></author>
           <guid></guid>
           <category>Multi oil circuit breaker</category>
           <pubDate>2026-6-10 20:53:53</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200711/2007117121941293.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 327px; WIDTH: 552px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline and Installation Dimensional Drawing of DW8-35 High Voltage Multi Oil Circuit Breaker&quot; src=&quot;/uploadfiles/200711/2007117121941293.jpg&quot; width=552 height=327&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201405/20140508215131114.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 895px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of DW8-35 high-voltage multi oil circuit breaker&quot; src=&quot;/upload2014/201405/20140508215131114.jpg&quot; width=680 height=895&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DW8-35 High Voltage Multi Oil Circuit Breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Multi oil circuit breaker]DW13-35 Series Outdoor AC High Voltage Multi Oil Circuit Breaker </title>
           <link>http://www.91way.com/info_en/2870.html</link>
           <author></author>
           <guid></guid>
           <category>Multi oil circuit breaker</category>
           <pubDate>2026-6-10 20:53:44</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The DW13-35 high-voltage multi oil circuit breaker complies with national standards and is used for the protection of 35KV power systems Interlocking between control and system Circuit breakers are divided into two types: those without parallel resistors and those with parallel resistors, both of which have the same technical parameters and basic skills. Circuit breakers with parallel resistors also have reliable performance in meeting no-load long lines. Users must meet the requirements of no-load long lines. Circuit breakers can be used in heavily polluted areas and high-altitude areas&lt;BR&gt;&lt;BR&gt;Main technical parameters of DW13-35 series outdoor AC high-voltage multi oil circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=312 colSpan=2 align=center&gt;Project&lt;/TD&gt;
&lt;TD rowSpan=2 width=72 align=center&gt;Unit&lt;/TD&gt;
&lt;TD width=264 colSpan=4 align=center&gt;Technical data&lt;/TD&gt;
&lt;TD rowSpan=2 width=124 align=center&gt;Remarks&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131 colSpan=2 align=center&gt;DW13-35 type&lt;/TD&gt;
&lt;TD width=131 colSpan=2 align=center&gt;DW132-35 Type I&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;rated voltage&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KV&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;35£¨36£©&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;35£¨36£©&lt;/TD&gt;
&lt;TD width=124 align=center&gt;Note 1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=20 width=312 colSpan=2&gt;Main maximum operating voltage&lt;/TD&gt;
&lt;TD height=20 width=72 align=center&gt;KV&lt;/TD&gt;
&lt;TD height=20 width=132 colSpan=2 align=center&gt;40.5(36)&lt;/TD&gt;
&lt;TD height=20 width=132 colSpan=2 align=center&gt;40.5(36)&lt;/TD&gt;
&lt;TD width=124 align=center&gt;Note 1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;rated frequency&lt;/TD&gt;
&lt;TD width=72 align=center&gt;Hz&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;rated current&lt;/TD&gt;
&lt;TD width=72 align=center&gt;A&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;twenty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated out of step breaking current&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;five&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;eight&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated short-circuit closing current (peak)&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Dynamic stability current (peak value)&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;dynamic stable current&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KA&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;twenty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated thermal stability time&lt;/TD&gt;
&lt;TD width=72 align=center&gt;S&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;four&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;four&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated transient recovery voltage during short circuit at the output terminal (peak value, full capacity breaking)&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KV&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;sixty-nine point four&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;sixty-nine point four&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated lightning impulse withstand voltage (peak)&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KV&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one hundred and eighty-five&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one hundred and eighty-five&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD width=72 align=center&gt;KV&lt;/TD&gt;
&lt;TD width=71 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=60 align=center&gt;ninety-five&lt;/TD&gt;
&lt;TD width=62 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=69 align=center&gt;ninety-five&lt;/TD&gt;
&lt;TD width=124 align=center&gt;Note 2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;closing time&lt;/TD&gt;
&lt;TD width=72 align=center&gt;S&lt;/TD&gt;
&lt;TD width=129 colSpan=2 align=center&gt;¡Ü0.35&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;¡Ü0.35&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Opening time&lt;/TD&gt;
&lt;TD width=72 align=center&gt;S&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;¡Ü0.07&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;¡Ü0.07&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Total breaking time &lt;/TD&gt;
&lt;TD width=72 align=center&gt;S&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=124 align=center&gt;Note 3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Metal short circuit time during &quot;closing and opening&quot; operation&lt;/TD&gt;
&lt;TD width=72 align=center&gt;S&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;zero point one&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD width=72 align=center&gt;&lt;/TD&gt;
&lt;TD width=388 colSpan=5 align=center&gt;0.5S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=44 rowSpan=2 width=128&gt;Applicable altitude&lt;/TD&gt;
&lt;TD width=181&gt;Used for protection control&lt;/TD&gt;
&lt;TD width=72 align=center&gt;m&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;four thousand&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;four thousand&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;Used for communication&lt;/TD&gt;
&lt;TD width=72 align=center&gt;m&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;three thousand&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;three thousand&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Cut the length of the empty line&lt;/TD&gt;
&lt;TD width=72 align=center&gt;Km&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Ceramic sleeve creepage distance&lt;/TD&gt;
&lt;TD width=72 align=center&gt;cm&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one hundred and five&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one hundred and five&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;Circuit breaker weight (with mechanism, oil-free)&lt;/TD&gt;
&lt;TD width=72 align=center&gt;kg&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one thousand three hundred and fifty&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;one thousand nine hundred and thirty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;oil weight&lt;/TD&gt;
&lt;TD width=72 align=center&gt;kg&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;three hundred and seventy&lt;/TD&gt;
&lt;TD width=132 colSpan=2 align=center&gt;five hundred and fifty&lt;/TD&gt;
&lt;TD width=124 align=center&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;1. There are differences between the rated voltage regulations of IEC standards and national standards. When providing products according to the IE56 standard, the rated voltage and maximum operating voltage are taken from the data in parentheses.&lt;BR&gt;2. The actual short-term power frequency durability of the circuit breaker is higher than the standard specified 80KV, and the factory designs and tests it according to 95KV.&lt;BR&gt;3. The fully open break time is the measured data after the short-circuit break test.&lt;BR&gt;&lt;BR&gt;Installation dimensions of DW13-35 series outdoor AC high-voltage multi oil circuit breaker&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200711/2007117121746701.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 324px; WIDTH: 552px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DW13-35 series outdoor AC high-voltage multi oil circuit breaker appearance and installation dimension diagram&quot; src=&quot;/uploadfiles/200711/2007117121746701.jpg&quot; width=524 height=324&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
