<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - low-voltage contactor</title>
       <link>http://www.91way.com</link>
       <description>low-voltage contactor</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:13:29</pubDate>
       <item>
           <title>[Low voltage vacuum contactor]CKJ3-200A/2KV type vacuum contactor </title>
           <link>http://www.91way.com/info_en/25145.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:47</pubDate>
           <comments></comments>
           <description>Main technical parameters of CKJ3-200A/2KV vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=6&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=9 width=54&gt;
&lt;P align=center&gt;circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Rated working voltage (Ue)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Rated working current (Ie)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Rated frequency (fr)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;50~60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Rated connection capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;12Ie (AC-4)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Rated breaking capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;10Ie (AC-4)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Ability to withstand overload current per second&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;8Ie/10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=122 colSpan=2&gt;
&lt;P align=center&gt;Power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156 colSpan=3&gt;
&lt;P align=center&gt;Alternating and relative to each other&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;four point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=156 colSpan=3&gt;
&lt;P align=center&gt;Vacuum fracture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=278 colSpan=5&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=118 colSpan=2&gt;
&lt;P align=center&gt;control circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=214 colSpan=4&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;36/110/220&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107 colSpan=3&gt;
&lt;P&gt;Rated power (Ps)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;Electricity maintenance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;VA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P&gt;¡Ü 250/40 (suction/hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=187 colSpan=4&gt;
&lt;P align=center&gt;auxiliary circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144 colSpan=2&gt;
&lt;P align=center&gt;form&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;1a£«1b&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144 colSpan=2&gt;
&lt;P&gt;rated value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;AC 380V/5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=6&gt;
&lt;P align=center&gt;Control circuit and auxiliary circuit withstand voltage to ground frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=187 colSpan=4&gt;
&lt;P align=center&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144 colSpan=2&gt;
&lt;P align=center&gt;Long term or mechanical maintenance type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Times/h&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144 colSpan=2&gt;
&lt;P align=center&gt;short-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Times/h&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;three thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=6&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=6&gt;
&lt;P align=center&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;60(AC-3)£¬6(AC-4)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=118 colSpan=2&gt;
&lt;P align=center&gt;mechanical properties&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=214 colSpan=4&gt;
&lt;P align=center&gt;closing time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;¡Ü200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=214 colSpan=4&gt;
&lt;P align=center&gt;Inherent opening time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;¡Ü 160 (electric hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=214 colSpan=4&gt;
&lt;P align=center&gt;3 different stages&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;¡Ü3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=214 colSpan=4&gt;
&lt;P align=center&gt;Closing bounce&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;¡Ü10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=568 colSpan=8&gt;
&lt;P align=center&gt;Note: 1. The control voltage can also be customized according to user needs. 2. Can only be used for rotor circuits.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;A href=&quot;/upload2014/201405/20140505055242770.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 528px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ3-200A/2KV vacuum contactor&quot; src=&quot;/upload2014/201405/20140505055242770.jpg&quot; width=680 height=528&gt;&lt;/A&gt;&lt;BR&gt;CKJ3-200A/2KV type vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ2-800/1000/1250A/1140V-A series bipolar vacuum contactor </title>
           <link>http://www.91way.com/info_en/25144.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:39</pubDate>
           <comments></comments>
           <description>CKJ2-800/1000/1250A/1140V-A series bipolar vacuum contactor rated parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=4&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;parameter&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=31&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;main&lt;/P&gt;
&lt;P&gt;electricity&lt;/P&gt;
&lt;P&gt;road&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated working voltage (Ue)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated working current (Ie)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;800£¬1000£¬1250&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated heating current (Ith)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;800£¬1000£¬1250&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated connection capacity (I)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;4Ie&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated breaking capacity (Ic)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;4Ie&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;50/60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=31&gt;
&lt;P&gt;control&lt;/P&gt;
&lt;P&gt;manufacture&lt;/P&gt;
&lt;P&gt;electricity&lt;/P&gt;
&lt;P&gt;road&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P&gt;Rated voltage (Us) 1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;AC.220/380£¬DC.110/220&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=96&gt;
&lt;P&gt;rated power&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=216 colSpan=2&gt;
&lt;P&gt;pickup&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;P align=center&gt;VA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;¡Ü100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216 colSpan=2&gt;
&lt;P&gt;maintain&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;¡Ü100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=3&gt;
&lt;P&gt;auxiliary circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;form&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;3a£«3b&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;rated value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;380V/AC.5A or DC.1A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=3&gt;
&lt;P&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;long-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;P align=center&gt;Times/h&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;short-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=4&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=4&gt;
&lt;P&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;50(AC-2)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=568 colSpan=6&gt;
&lt;P&gt;*Note: The rated control voltage can also be customized according to user needs. &amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=0&gt;
&lt;TD width=31&gt;&lt;/TD&gt;
&lt;TD width=96&gt;&lt;/TD&gt;
&lt;TD width=84&gt;&lt;/TD&gt;
&lt;TD width=132&gt;&lt;/TD&gt;
&lt;TD width=48&gt;&lt;/TD&gt;
&lt;TD width=177&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Technical requirements for CKJ2-800/1000/1250A/1140V-A series bipolar vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;P align=center&gt;Technical Requirements&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;parameter&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;P align=center&gt;power frequency&lt;/P&gt;
&lt;P align=center&gt;tolerance&lt;/P&gt;
&lt;P align=center&gt;voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=96&gt;
&lt;P align=center&gt;main circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Interphase and relative ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;four point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;vacuum interrupter gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Control circuit to ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Auxiliary circuit to ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;P align=center&gt;mechanical&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;feature&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;closing time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;Inherent opening time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü 160 (electric hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;Three phases in different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;Closing bounce&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CKJ2-800/1000/1250A/1140V-A series bipolar vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-1250/1.14kV Low voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/22972.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130313083933598.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 823px&quot; border=0 hspace=0 alt=&quot;Technical parameters and external dimensions of CKJ5-1250/1.14kV low-voltage vacuum contactor&quot; src=&quot;/upload2013/201303/20130313083933598.jpg&quot; width=660 height=823&gt;&lt;/A&gt;&lt;BR&gt;CKJ5-1250/1.14kV Low Voltage Vacuum Contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ-315/1.14 AC Low Voltage Vacuum Contactor </title>
           <link>http://www.91way.com/info_en/22109.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:23</pubDate>
           <comments></comments>
           <description>1. Scope of use&lt;BR&gt;The CKJ-315/1.14 AC low-voltage vacuum contactor is used in a current system with an AC frequency of 50Hz, a rated working voltage of 1140V in the main circuit, and a rated working current of 315A. It is used for remote connection and disconnection of circuits, as well as frequent starting and control of AC motors. And it is suitable for forming a magnetic starter with various protective devices, with the characteristics of not exposing the arc. Especially suitable for forming explosion-proof magnetic starters. Suitable for industries such as coal mining or petroleum.&lt;BR&gt;&lt;BR&gt;2. Basic parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=116&gt;&lt;/TD&gt;
&lt;TD width=137 colSpan=2&gt;
&lt;P align=center&gt;Rated voltage (power frequency) (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=76&gt;
&lt;P align=center&gt;rated current&lt;BR&gt;(Main circuit)&lt;BR&gt;(A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=222 colSpan=3&gt;
&lt;P align=center&gt;Main contact parameters (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213 colSpan=3&gt;
&lt;P align=center&gt;Power frequency voltage V (effective value)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;main circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;control circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Open distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;overstroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;Final pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;main circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;auxiliary circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;control circuit&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=116&gt;
&lt;P align=center&gt;CKJ315/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;thirty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;£¾1.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;four thousand and two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=116&gt;
&lt;P align=center&gt;HGZ-300/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;4.5&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;four thousand and two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;-&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=119&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=88&gt;
&lt;P align=center&gt;Connection capability&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=71&gt;
&lt;P align=center&gt;Distribution ability&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=157&gt;
&lt;P align=center&gt;Ultimate breaking current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=133 colSpan=2&gt;
&lt;P align=center&gt;Number of electrical life cycles&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=119&gt;
&lt;P align=center&gt;Mechanical lifespan times&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=73&gt;
&lt;P align=center&gt;quality&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;AC3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;AC4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;CKJ315/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;10Ie, 100 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;8Ie, 25 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4500,3 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;60&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;150&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P align=center&gt;11kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;HGZ-300/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;10Ie, 100 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;8Ie, 25 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4500,3 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;60&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;150&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]Single pole low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/20713.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:14</pubDate>
           <comments></comments>
           <description>CKJ5-600-1 Single pole Low voltage Vacuum Contactor&lt;BR&gt;&lt;BR&gt;Rated voltage 1140V, rated current 600A, ultimate breaking capacity 6000A, mass 20kg.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-800 Low voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/20712.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:31:06</pubDate>
           <comments></comments>
           <description>CKJ5-800 Low Voltage Vacuum Contactor&lt;BR&gt;&lt;BR&gt;Rated voltage 1140V, rated current 800A, ultimate breaking capacity 6000A, mass 20kg.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]7306) Type High Load DC Contactor </title>
           <link>http://www.91way.com/info_en/20226.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:58</pubDate>
           <comments></comments>
           <description>JQ-43F type high load DC contactor (7306) has a large load, stable and reliable operation, and can be widely used in various fields such as heavy engineering vehicle electrical device switching, ground power switching, etc&lt;BR&gt;&lt;BR&gt;Product specifications: 12VDC, 24VDC, 36VDC, 48VDC&lt;BR&gt;Load: 100A, 220VAC; 100A,60VDC&lt;BR&gt;Product size: 38.5mm &#215; 27.5mm &#215; 83mm&lt;BR&gt;Product weight: ¡Ü 380g&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]JQ-57F type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/20224.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:50</pubDate>
           <comments></comments>
           <description>The JQ-57F high-power DC contactor has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies&lt;BR&gt;&lt;BR&gt;Product specification: 28VDC&lt;BR&gt;Load: 500A, 28Vd. c&lt;BR&gt;Product size: 70mm &#215; 127mm &#215; 60.5mm&lt;BR&gt;Product weight: ¡Ü 800g&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-160/1.14KV AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15902.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:42</pubDate>
           <comments></comments>
           <description>CKJ5-160/1.14KV AC vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=3&gt;Product Technical Parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;rated current&lt;/TD&gt;
&lt;TD width=80&gt;A&lt;/TD&gt;
&lt;TD width=160&gt;one hundred and sixty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one point one four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/100 times&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/25 times&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1.8 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;three point seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=33&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;36, 127, 220, 380, or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201103/20110329083024957.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 570px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-160/1.14KV AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110329083024957.jpg&quot; width=300 height=570&gt;&lt;/A&gt;&lt;BR&gt;CKJ5-160/1.14KV AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CV-160/1.14KV AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15901.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CV-160/1.14KV AC vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Product Technical Parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;rated current&lt;/TD&gt;
&lt;TD width=80&gt;A&lt;/TD&gt;
&lt;TD width=160&gt;one hundred and sixty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one point one four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1.8 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;three point seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=33&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;36, 127, 220, 380, or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110329082839957.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 361px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CV-160/1.14KV AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110329082839957.jpg&quot; width=400 height=361&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CV-160/1.14KV AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CHV-400/3.3KV AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15900.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:25</pubDate>
           <comments></comments>
           <description>CHV-400/3.3KV AC vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=3&gt;Product Technical Parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;rated current&lt;/TD&gt;
&lt;TD width=80&gt;A&lt;/TD&gt;
&lt;TD width=160&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;three point three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;three thousand and two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;3 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;110, 220 or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201103/20110329082539785.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 711px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CHV-400/3.3KV AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110329082539785.jpg&quot; width=350 height=711&gt;&lt;/A&gt;&lt;BR&gt;CHV-400/3.3KV AC vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-800/1.5 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15891.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:17</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Product Technical Parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;eight thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;six thousand and four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;eight thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;2 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=33&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;110, 220 or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110329080425759.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 334px; HEIGHT: 477px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ11-800/1.5 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110329080425759.jpg&quot; width=334 height=477&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ11-800/1.5 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-400/1.5 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15890.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:09</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=280 colSpan=3&gt;
&lt;P&gt;Product Technical Parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;400&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Rated connection capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Rated breaking capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Ultimate breaking ability&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/3 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;four thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;2&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;overstroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;1&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one hundred and six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;6&#215;104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Reference weight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;seven point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Control power supply voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;110, 220 or customized according to user requirements&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110328224831797.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 327px; HEIGHT: 537px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ11-400/1.5 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328224831797.jpg&quot; width=327 height=537&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ11-400/1.5 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-250/1.5 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15889.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:30:01</pubDate>
           <comments></comments>
           <description>CKJ11-250/1.5 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=280 colSpan=3&gt;
&lt;P&gt;Product Technical Parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;250&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated connection capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated breaking capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Ultimate breaking ability&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/3 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;four thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;2&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;overstroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;1&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one hundred and six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;6&#215;104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Reference weight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Control power supply voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;110, 220 or customized according to user requirements&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110328224507695.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 309px; HEIGHT: 454px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ11-250/1.5 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328224507695.jpg&quot; width=309 height=454&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ11-250/1.5 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-160/1.5 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15888.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:52</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=280 colSpan=3&gt;
&lt;P&gt;Product Technical Parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;160&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Rated connection capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Rated breaking capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/50 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one thousand two hundred and eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Ultimate breaking ability&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;A/3 times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;2&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;overstroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;1&amp;nbsp;&#177;&amp;nbsp;0.2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;one hundred and six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;6&#215;104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Reference weight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;three point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;Control power supply voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P&gt;110, 220 or customized according to user requirements&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110328224333649.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 322px; HEIGHT: 478px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ11-160/1.5 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328224333649.jpg&quot; width=322 height=478&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ11-160/1.5 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-80/1.14 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15887.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:44</pubDate>
           <comments></comments>
           <description>&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=3&gt;Technical parameters of CKJ5-80/1.14 AC vacuum contactor&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;rated current&lt;/TD&gt;
&lt;TD width=80&gt;A&lt;/TD&gt;
&lt;TD width=160&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one point one four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/100 times&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/25 times&lt;/TD&gt;
&lt;TD&gt;six hundred and forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1.2 + 0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;one point eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=33&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;36, 127, 220, 380, or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201103/20110328224130898.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 597px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-80/1.14 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328224130898.jpg&quot; width=400 height=597&gt;&lt;/A&gt;&lt;BR&gt;CKJ5-80/1.14 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-500/3.6 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15886.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:36</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;CKJ11-500/3.3 AC vacuum contactor is suitable for use in power systems with AC 50Hz, rated working voltage of 3.6KV and below in the main circuit, and rated working current of 500A and below, for connecting and disconnecting circuits. Suitable for controlling the frequent starting and stopping of AC motors, it can be combined with various protective devices to form a magnetic starter, widely used in various fields such as power systems, petroleum, chemical, coal mining, metallurgy, and electrified railways.&lt;BR&gt;&lt;BR&gt;2¡¢ Working conditions&lt;BR&gt;1. Environmental temperature: -25 ¡æ~40 ¡æ.&lt;BR&gt;2. Altitude: not exceeding 2000m&lt;BR&gt;3. Relative humidity: The relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is 40 ¡æ. Higher relative humidity is allowed at lower temperatures. When the average temperature of the wettest month is 20 ¡æ, the maximum monthly average relative humidity is 90%, taking into account condensation that occurs on the surface of the product due to temperature changes.&lt;BR&gt;4. Working environment: No rain, snow, open flames, explosion hazards, or strong vibrations.&lt;BR&gt;5. Installation conditions: The inclination angle between the installation surface and the vertical surface shall not exceed &#177; 15 &#176;.&lt;BR&gt;6. Pollution level: Level III.&lt;BR&gt;7. Installation category: Installation category 3.&lt;BR&gt;&lt;BR&gt;3¡¢ Product model and its significance&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201103/20110328223747564.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 112px&quot; border=0 hspace=0 alt=&quot;Model Description of CKJ11-500/3.6 AC Vacuum Contactor&quot; src=&quot;/upload2011/201103/20110328223747564.jpg&quot; width=250 height=112&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;4¡¢ Structure and working principle&lt;BR&gt;This contactor is mainly composed of vacuum switch tube, insulation base, electromagnetic operating mechanism and other parts. When the control power is turned on, the armature attracts and drives the rocker plate to rotate. The moving contact of the vacuum switch tube closes with the stationary contact under the combined action of self closing force and contact spring, connecting the main circuit. When the control power is cut off, the electromagnetic holding force disappears, the opening spring releases the armature, rotates the rocker plate, opens the moving contact of the vacuum switch tube, releases the contactor, and disconnects the main circuit.&lt;BR&gt;5¡¢ Product Technical Parameters&lt;BR&gt;Rated voltage: 3.6KV Rated current: 500A&lt;BR&gt;Contact opening distance: 4 &#177; 0.5mm Mechanism overtravel: 2 &#177; 0.5mm&lt;BR&gt;Rated connection capacity: 5000A, 50 times&lt;BR&gt;Rated breaking capacity: 4000A, 50 times&lt;BR&gt;Ultimate breaking capacity: 5000A, 3 times&lt;BR&gt;Mechanical lifespan: 1 million cycles&lt;BR&gt;Electrical lifespan (AC4): 60000 cycles&lt;BR&gt;Control power supply voltage: 220V, or customized according to user requirements&lt;BR&gt;&lt;BR&gt;6¡¢ Installation and maintenance&lt;BR&gt;Before installation, it is necessary to check and confirm that the contactor has correct model specifications, control voltage, and other parameters;&lt;BR&gt;2. The installation surface should be flat and clean, the installation feet should be evenly stressed, and the fasteners should be firm and reliable;&lt;BR&gt;3. During installation, attention should be paid to preventing foreign objects from falling in, so as not to cause the mechanism to get stuck;&lt;BR&gt;4. Pay attention to the electrical wiring to prevent stress on the contactor;&lt;BR&gt;5. Regularly clean the insulation frame, vacuum tube, and circuit system to ensure working insulation;&lt;BR&gt;6. Check if the fasteners are loose and if there are any abnormalities in the structural components;&lt;BR&gt;7. Check the erosion of auxiliary switch contacts and repair or replace them if necessary;&lt;BR&gt;8. Check whether the moving parts are flexible and lubricate them if necessary;&lt;BR&gt;9. Check if the opening distance and overtravel meet the requirements.&lt;BR&gt;10. The vacuum degree of the vacuum switch tube is generally checked using the power frequency withstand voltage method, and its withstand voltage value should not be less than 1/2 of the rated value.&lt;BR&gt;&lt;BR&gt;7¡¢ Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110328223807111.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ11-500/3.6 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328223807111.jpg&quot; width=300 height=270&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201103/20110328223817107.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 280px; HEIGHT: 179px&quot; border=0 hspace=0 alt=&quot;CKJ11-500/3.6 AC Vacuum Contactor Dimensions 1&quot; src=&quot;/upload2011/201103/20110328223817107.jpg&quot; width=280 height=179&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201103/20110328223825739.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 292px; HEIGHT: 208px&quot; border=0 hspace=0 alt=&quot;CKJ11-500/3.6 AC Vacuum Contactor Dimensions 2&quot; src=&quot;/upload2011/201103/20110328223825739.jpg&quot; width=292 height=208&gt;&lt;/A&gt;&lt;BR&gt;The appearance and installation dimensions are shown in the attached diagram. Figure 2 is of type A, and Figure 3 is of type B, with the only difference being the position of the conductive plate.&lt;/P&gt;
&lt;P align=left&gt;8¡¢ Transportation and storage&lt;BR&gt;1. During loading and unloading, it is not allowed to throw or collide. During transportation, it is not allowed to invert, roll, or vibrate violently, and rain or snow should be avoided from entering;&lt;BR&gt;2. The contactor should be stored in a warehouse that is free from water invasion, corrosive and flammable gases, has good air circulation, is dry, and has a temperature range of -25 ¡æ to 40 ¡æ;&lt;BR&gt;3. The contactor should not be placed on the ground for a long time and should be stored in a plastic bag;&lt;BR&gt;Products stored for more than 6 months should be inspected before use.&lt;BR&gt;&lt;BR&gt;9¡¢ Ordering Notice&lt;BR&gt;When ordering products, the following information must be stated:&lt;BR&gt;1. Product name, model, specifications, and installation form;&lt;BR&gt;2. Rated working voltage and rated working current;&lt;BR&gt;3. Rated control voltage;&lt;BR&gt;4. Product quantity;&lt;BR&gt;5. Spare parts or other special requirements.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CV-80/1.14 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/15885.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:28</pubDate>
           <comments></comments>
           <description>&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=3&gt;Product Technical Parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one point one four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated connection capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking capacity&lt;/TD&gt;
&lt;TD&gt;A/50 times&lt;/TD&gt;
&lt;TD&gt;six hundred and forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Ultimate breaking ability&lt;/TD&gt;
&lt;TD&gt;A/3 times&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1.5&#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;overstroke&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD&gt;1 &#177; 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;ten&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;
&lt;TD&gt;6&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Reference weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;one point eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=33&gt;Control power supply voltage&lt;/TD&gt;
&lt;TD&gt;V&lt;/TD&gt;
&lt;TD&gt;110, 220 or customized according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201103/20110328223530252.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 327px; HEIGHT: 501px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CV-80/1.14 AC vacuum contactor&quot; src=&quot;/upload2011/201103/20110328223530252.jpg&quot; width=327 height=501&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CV-80/1.14 AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]ALYC-36B Mining contactor electronic controller </title>
           <link>http://www.91way.com/info_en/13108.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:19</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508142525455.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 524px; HEIGHT: 703px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of ALYC-36B mining contactor electronic controller&quot; src=&quot;/upload2010/201005/20100508142525455.jpg&quot; width=524 height=703&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ALYC-36B Mining Contactor Electronic Controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]ALYC-36A Mining Contact Electronic Controller </title>
           <link>http://www.91way.com/info_en/13107.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:10</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508142334738.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 524px; HEIGHT: 703px&quot; border=0 hspace=0 alt=&quot;ALYC-36A Mining Contact Electronic Controller - Dimensions and Technical Parameters&quot; src=&quot;/upload2010/201005/20100508142334738.jpg&quot; width=524 height=703&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ALYC-36A Mining Contact Electronic Controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]ALYC-220D Permanent magnet electronic controller </title>
           <link>http://www.91way.com/info_en/13106.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:29:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508141331651.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 531px; HEIGHT: 611px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of ALYC-220D permanent magnet electronic controller&quot; src=&quot;/upload2010/201005/20100508141331651.jpg&quot; width=531 height=611&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508142148285.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 696px&quot; border=0 hspace=0 alt=&quot;ALYC-220D Permanent Magnet Electronic Controller Wiring Diagram&quot; src=&quot;/upload2010/201005/20100508142148285.jpg&quot; width=550 height=696&gt;&lt;/A&gt;&lt;BR&gt;ALYC-220D Permanent Magnet Electronic Controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]ALYC-220G Permanent magnet electronic controller </title>
           <link>http://www.91way.com/info_en/13105.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508140958312.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 531px; HEIGHT: 708px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of ALYC-220G permanent magnet electronic controller&quot; src=&quot;/upload2010/201005/20100508140958312.jpg&quot; width=531 height=708&gt;&lt;/A&gt;&lt;BR&gt;ALYC-220G Permanent Magnet Electronic Controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5M-250A Mining arc free permanent magnet vacuum contactor </title>
           <link>http://www.91way.com/info_en/13104.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508112612524.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 527px; HEIGHT: 722px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CKJ5M-250A mining arc free permanent magnet vacuum contactor&quot; src=&quot;/upload2010/201005/20100508112612524.jpg&quot; width=527 height=722&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508112621285.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 545px; HEIGHT: 722px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5M-250A mining arc free permanent magnet vacuum contactor&quot; src=&quot;/upload2010/201005/20100508112621285.jpg&quot; width=545 height=722&gt;&lt;/A&gt;&lt;BR&gt;CKJ5M-250A Mining Non Arc Permanent Magnet Vacuum Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5M-160/1140 Mining arc free permanent magnet vacuum contactor </title>
           <link>http://www.91way.com/info_en/13103.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508112058739.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 545px; HEIGHT: 708px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ5M-160/1140 mining non arc permanent magnet vacuum contactor&quot; src=&quot;/upload2010/201005/20100508112058739.jpg&quot; width=545 height=708&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508112109750.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 538px; HEIGHT: 722px&quot; border=0 hspace=0 alt=&quot;CKJ5M-160/1140 Mine Non Arc Permanent Magnet Vacuum Contactor Wiring Diagram and Installation Dimensions&quot; src=&quot;/upload2010/201005/20100508112109750.jpg&quot; width=538 height=722&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508112118281.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 537px; HEIGHT: 705px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5M-160/1140 mining arc free permanent magnet vacuum contactor&quot; src=&quot;/upload2010/201005/20100508112118281.jpg&quot; width=537 height=705&gt;&lt;/A&gt;&lt;BR&gt;CKJ5M-160//1140 mining non arc permanent magnet vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5M-1.14/400A Mining arc free permanent magnet vacuum contactor </title>
           <link>http://www.91way.com/info_en/13100.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201005/20100508093407611.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 567px; HEIGHT: 726px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ5M-1.14/400A mining non arc permanent magnet vacuum contactor&quot; src=&quot;/upload2010/201005/20100508093407611.jpg&quot; width=567 height=726&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508093420245.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 567px; HEIGHT: 726px&quot; border=0 hspace=0 alt=&quot;Installation Instructions for CKJ5M-1.14/400A Mine Non Arc Permanent Magnet Vacuum Contactor&quot; src=&quot;/upload2010/201005/20100508093420245.jpg&quot; width=567 height=726&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508093429898.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 536px; HEIGHT: 719px&quot; border=0 hspace=0 alt=&quot;CKJ5M-1.14/400A Mining Non Arc Permanent Magnet Vacuum Contactor Installation Dimensions&quot; src=&quot;/upload2010/201005/20100508093429898.jpg&quot; width=536 height=719&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201005/20100508093440682.jpg&quot; target=_blank&gt;&lt;/A&gt;&lt;BR&gt;CKJ5M-1.14/400A mining non arc permanent magnet vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ313-630A/1140V type vacuum contactor </title>
           <link>http://www.91way.com/info_en/7261.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CKJ313-630A/1140V vacuum contactor is a CCC certified product, originally CKJ13-630A1140V&lt;BR&gt;Rated voltage: 1140V&lt;BR&gt;Rated current: 630A&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/2009102481930787.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 635px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ313-630A/1140V vacuum contactor&quot; src=&quot;/upload2009/200910/2009102481930787.jpg&quot; width=670 height=635&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Outline drawing of CKJ313-630A/1140V vacuum contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/200910248208907.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 626px; HEIGHT: 474px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ313-630A/1140V vacuum contactor&quot; src=&quot;/upload2009/200910/200910248208907.gif&quot; width=626 height=474&gt;&lt;/A&gt;&lt;BR&gt;CKJ313-630A/1140V type vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ50-(125,160)A/220-1140V series vacuum contactor </title>
           <link>http://www.91way.com/info_en/7260.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CKJ50- (125~160) A/2203801140V vacuum contactor is used for single-phase street lamp control&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009102481625348.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 593px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ50- (125160) A/220-1140V series vacuum contactor&quot; src=&quot;/upload2009/200910/2009102481625348.jpg&quot; width=670 height=593&gt;&lt;/A&gt;&lt;BR&gt;CKJ50- (125160) A/220-1140V series vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ12 Type (EVS)} Series AC Low Voltage Vacuum Contactor </title>
           <link>http://www.91way.com/info_en/7259.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:28:04</pubDate>
           <comments></comments>
           <description>The CKJ12 (EVS) series AC low-voltage vacuum contactor complies with IEC and VDE technical standards.&lt;BR&gt;This series of vacuum contactors has the advantages of high connection and disconnection capacity, long electrical and mechanical life, and high reliability under harsh conditions. It is particularly suitable for use in basic industries, metallurgy, petroleum, chemical, mining, and ports. It is suitable for power systems with AC 50HZ/60Hz, rated operating voltage up to 1140V, and rated operating current up to 630A. It can be used to connect and disconnect circuits at long and short distances, as well as to frequently start and control AC motors under heavy task conditions. It can also be combined with various protective devices to form electromagnetic actuators.&lt;BR&gt;&lt;BR&gt;parameter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse; HEIGHT: 227px&quot; border=1 cellSpacing=1 cellPadding=1 width=&quot;98%&quot; align=center height=227&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Rated working voltage Ue&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;1140V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Rated working current Ie&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;160A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Rated connection capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;1920A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Rated breaking capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;1600A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;The maximum allowable power of the motor is 660V50Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;140KW&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Suction time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;30ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;release time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;20ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22 width=437&gt;
&lt;P&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=22 width=386&gt;
&lt;P align=center&gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P&gt;Maximum operating frequency (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=437&gt;
&lt;P align=left&gt;Electrical lifespan Ac2&lt;/P&gt;
&lt;P&gt;Ac3&lt;/P&gt;
&lt;P&gt;Ac4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=386&gt;
&lt;P align=center&gt;5&#215;106&lt;BR&gt;5&#215;106&lt;BR&gt;0.12&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Usage conditions:&lt;BR&gt;(1) The normal working conditions of this contactor comply with GB/T14048.1-2000 &quot;Low voltage switchgear and control equipment&quot;&lt;BR&gt;(2) Allowable ambient air temperature: -5 ¡æ -40 ¡æ&lt;BR&gt;(3) Relative humidity: At a temperature of 25 ¡æ, the maximum relative humidity can reach 90%&lt;BR&gt;(4) Pollution level: Level 3&lt;BR&gt;(5) Altitude: not exceeding 2000 meters&lt;BR&gt;(6) Installation conditions: Vertically upward (with the drive mechanism on top), with the installation area tilted no more than 15 &#176; from the vertical plane&lt;BR&gt;&lt;BR&gt;Outline drawing of CKJ12 (EVS) series AC low-voltage vacuum contactor:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=20 align=middle&gt;model&lt;/TD&gt;
&lt;TD align=middle&gt;polar number&lt;/TD&gt;
&lt;TD align=middle&gt;W0&lt;/TD&gt;
&lt;TD align=middle&gt;W1&lt;/TD&gt;
&lt;TD align=middle&gt;W2&lt;/TD&gt;
&lt;TD align=middle&gt;W3&lt;/TD&gt;
&lt;TD align=middle&gt;W4&lt;/TD&gt;
&lt;TD align=middle&gt;W5&lt;/TD&gt;
&lt;TD align=middle&gt;H0&lt;/TD&gt;
&lt;TD align=middle&gt;H1&lt;/TD&gt;
&lt;TD align=middle&gt;H2&lt;/TD&gt;
&lt;TD align=middle&gt;H3&lt;/TD&gt;
&lt;TD align=middle&gt;D1&lt;/TD&gt;
&lt;TD align=middle&gt;D2&lt;/TD&gt;
&lt;TD align=middle&gt;D3&lt;/TD&gt;
&lt;TD align=middle&gt;D4&lt;/TD&gt;
&lt;TD align=middle&gt;¦µ1&lt;/TD&gt;
&lt;TD align=middle&gt;¦µ2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=20 width=52 align=middle&gt;&lt;/TD&gt;
&lt;TD width=32 align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;FONT size=-1&gt;installation dimensions&lt;/FONT&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;FONT size=-1&gt;distance&lt;/FONT&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;FONT size=-1&gt;installation dimensions&lt;/FONT&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;FONT size=-1&gt;installation aperture&lt;/FONT&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;FONT size=-1&gt;installation aperture&lt;/FONT&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=52 align=middle&gt;CKJ12-160 type&lt;/TD&gt;
&lt;TD height=20 width=32 align=middle&gt;one&lt;/TD&gt;
&lt;TD width=53 align=middle&gt;fifty&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;seventy-five&lt;/TD&gt;
&lt;TD width=40 align=middle&gt;&lt;/TD&gt;
&lt;TD width=43 align=middle&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=47 align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD rowSpan=3 width=48 align=middle&gt;seventy-five&lt;/TD&gt;
&lt;TD rowSpan=3 width=70 align=middle&gt;two hundred and thirty-seven point five&lt;/TD&gt;
&lt;TD rowSpan=3 width=37 align=middle&gt;three hundred and ten&lt;/TD&gt;
&lt;TD rowSpan=3 width=36 align=middle&gt;two hundred and eighty-five&lt;/TD&gt;
&lt;TD rowSpan=3 width=35 align=middle&gt;two hundred and fifty-eight&lt;/TD&gt;
&lt;TD rowSpan=3 width=33 align=middle&gt;one hundred and fifty-six&lt;/TD&gt;
&lt;TD rowSpan=3 width=38 align=middle&gt;five&lt;/TD&gt;
&lt;TD rowSpan=3 width=39 align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD rowSpan=3 width=42 align=middle&gt;six point five&lt;/TD&gt;
&lt;TD rowSpan=3 width=73 align=middle&gt;seven&lt;/TD&gt;
&lt;TD rowSpan=3 width=74 align=middle&gt;eleven&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009102481229800.bmp&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 430px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ12 (EVS) series AC low-voltage vacuum contactor&quot; src=&quot;/upload2009/200910/2009102481229800.bmp&quot; width=430 height=330&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CKJ12 (EVS) series AC low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ10-630/1140 Permanent magnet vacuum contactor </title>
           <link>http://www.91way.com/info_en/6844.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:56</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;30%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;
&lt;DIV align=center&gt;CKJ5¡ª400/1140&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;
&lt;DIV align=center&gt;CKJ5¡ª630/1140&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated voltage of main circuit (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated current of main circuit (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Main circuit connection capability (A/100 times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Main circuit on/off capability (A/10 times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand and eight hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Ultimate breaking capacity (A/3 times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Electrical lifespan AC3 (10000 cycles)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Electrical lifespan AC4 (10000 cycles)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Mechanical lifespan (10000 cycles)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated operating frequency AC3 (times/H)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated operating frequency AC4 (times/H)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Short term operation frequency times/H (20S)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Contact opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2+0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.1+0.2&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Overtravel (MM)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1+0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1+0.2&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091018171656158.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 436px; HEIGHT: 292px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ10-630/1140 permanent magnet vacuum contactor&quot; src=&quot;/upload2009/200910/20091018171656158.jpg&quot; width=436 height=292&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091018171716593.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 584px; HEIGHT: 174px&quot; border=0 hspace=0 alt=&quot;CKJ10-630/1140 permanent magnet vacuum contactor model and appearance&quot; src=&quot;/upload2009/200910/20091018171716593.jpg&quot; width=584 height=174&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CKJ10-630/1140 permanent magnet vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ type single pole AC low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/6837.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:48</pubDate>
           <comments></comments>
           <description>One scope of application&lt;BR&gt;&lt;BR&gt;CKJ-80, The 125160 (single pole) AC low-voltage vacuum contactor is used in current systems with AC 50HZ, main circuit rated working voltage up to 1140V, and rated working current up to 160A, for remote connection and disconnection of circuits and frequent starting and control of AC motors. And it is suitable for forming a magnetic starter with various protective devices, with the characteristics of not exposing the arc. Especially suitable for forming explosion-proof magnetic starters. Suitable for industries such as coal mining or petroleum.&lt;BR&gt;Single pole vacuum contactors are divided into vertical and horizontal types.&lt;BR&gt;&lt;BR&gt;II 1. Main technical parameters - horizontal&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=88&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=80&gt;
&lt;DIV align=center&gt;Number of poles in the main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=170 colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage (power frequency) (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=89&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=257 colSpan=3&gt;
&lt;DIV align=center&gt;Main contact parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;control circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=89&gt;
&lt;DIV align=center&gt;Opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;DIV align=center&gt;Overtravel (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;Final pressure (N)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88&gt;
&lt;DIV align=center&gt;CKJ-125-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;three hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=89&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=89&gt;
&lt;DIV align=center&gt;1.5&#177;0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;DIV align=center&gt;£¾1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;30&#177;3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=88&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=97&gt;
&lt;DIV align=center&gt;Connection capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;Distribution ability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;DIV align=center&gt;Ultimate breaking current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=145&gt;
&lt;DIV align=center&gt;Number of electrical life cycles&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;quality&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88&gt;
&lt;DIV align=center&gt;CKJ-125-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=97&gt;
&lt;DIV align=center&gt;10 Ie, 100 times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;8 Ie, 25 times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2000,3 times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=145&gt;
&lt;DIV align=center&gt;60&#215;104&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;300&#215;104&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;2.2kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;2. Appearance and installation dimensions of CKJ type single pole AC low-voltage vacuum contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101815130630.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ type single pole AC low-voltage vacuum contactor&quot; src=&quot;/upload2009/200910/2009101815130630.jpg&quot; width=524 height=400&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CKJ type unipolar AC low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11-125N(S) reversible low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/4156.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:40</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;CKJ11-125N(S)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;260x170x150&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Installation size (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CKJ11-125N (S) reversible low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ11 series low-voltage vacuum contactor CJK11-80 CJK11-125 CJK11-125L CKJ11-125N(S) CKJ11-160</title>
           <link>http://www.91way.com/info_en/4155.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:31</pubDate>
           <comments></comments>
           <description>Technical parameters of CKJ11 low-voltage vacuum contactor:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=79 align=middle&gt;
&lt;P&gt;CJK11-80&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;CJK11-125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;CJK11-125L&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;CKJ11-125N(S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;CJK11-160&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;six hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;3x106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=79 align=middle&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;four point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;four point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;140x125x110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;189x146x110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;170x143x145&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;260x170x150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;180x160x130&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Installation size (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;
&lt;P&gt;120x105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;
&lt;P&gt;160x130&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;146x120&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74 align=middle&gt;
&lt;P&gt;104x452x98&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CKJ11 series low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ3-1600A/1140V AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/3238.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CKJ3-1140V series AC vacuum contactor is used for non inductive or micro load, resistance furnace, wound motor rotor circuit series resistance starting conversion, and is also suitable for frequent switching of other loads. Can replace air AC contactors in industries such as coal, petroleum, chemical, metallurgical, power, mining, and ports.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/200857164523384.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 395px; HEIGHT: 191px&quot; border=0 hspace=0 alt=&quot;CKJ3-1600A/1140V AC Vacuum Contactor Model Description&quot; src=&quot;/uploadfiles/200805/200857164523384.gif&quot; width=395 height=191&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CKJ3-800/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CKJ3-1000/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CKJ3-1250/1140&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CKJ3-1600/1140&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Rated working voltage (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Rated closing current (KA)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six point four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Maximum breaking current (KA)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six point two five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Operating frequency&lt;BR&gt;(times/hour)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;long-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;short-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Design mechanical lifespan (10000 cycles)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Under the condition of electrical lifespan (AC-3) (10000 cycles)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;control voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;220 or customized&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Dimensions L x B x H (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;387x318x290&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Installation size L x B (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;298x180&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Weight (KG)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;CKJ3-1600A/1140V AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ50-400N reversible AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/3237.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:15</pubDate>
           <comments></comments>
           <description>CKJ50-400N AC vacuum contactor&lt;BR&gt;&lt;BR&gt;1¡¢ Scope and Application&lt;BR&gt;CKJ50-400N AC vacuum contactor is suitable for use in equipment with AC 50Hz, rated voltage up to 1140V, and rated current up to 400A. It can be used for frequent starting and stopping of AC electric motors, as well as for forward and reverse conversion of motors. It is particularly suitable for special environments such as steel and chemical docks.&lt;BR&gt;&lt;BR&gt;2¡¢ Main technical parameters&lt;BR&gt;1. The rated data of this contactor is as follows:&lt;BR&gt;The rated working voltage is 1140VA;&lt;BR&gt;B Rated working current up to 400A;&lt;BR&gt;The rated voltage of the control circuit is AC 380V, 220V, and 36V.&lt;BR&gt;2. The main contact parameters are specified in the table below:&lt;BR&gt;3. Working system of this contactor: intermittent long-term working system.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 50px&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center height=50&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=117&gt;
&lt;DIV align=center&gt;Initial pressure (kg)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;Final pressure (kg)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;Opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;Overtravel (mm)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=117&gt;
&lt;DIV align=center&gt;11.5&#177;1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;12&#177;1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;2&#177;0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113&gt;
&lt;DIV align=center&gt;1&#177;0.1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=left&gt;3¡¢ CKJ50-400N AC vacuum contactor appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/200857151922738.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 272px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ50-400N AC vacuum contactor&quot; src=&quot;/uploadfiles/200805/200857151922738.gif&quot; width=540 height=272&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ50-400N AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-600 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/2221.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:27:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The CKJ5-600 AC vacuum contactor is suitable for feeding networks with AC 50HZ, rated voltage of 1140V, and rated current up to 600A. It is used for remote connection and disconnection of circuits, as well as frequent starting and stopping of AC motors. It is also suitable for assembly with various devices to form explosion-proof electromagnetic starting machines Single pole contactors will be particularly suitable for the renovation of street lamps and airport lighting control power departments.&lt;BR&gt;Technical Specifications&lt;BR&gt;Model CKJ5-600; Level: 3&lt;BR&gt;Rated voltage 1140 (V)&lt;BR&gt;Rated current 600A (A)&lt;BR&gt;Control voltage 36-110-127-220-380 (V)&lt;BR&gt;Main circuit connection capacity 6000A 100 times&lt;BR&gt;Main circuit breaking capacity 4800A 25 times&lt;BR&gt;Limit breaking 6000A 3 times&lt;BR&gt;Electrical lifespan AC4 0.5 (10000 cycles)&lt;BR&gt;Mechanical lifespan of 3 million cycles&lt;BR&gt;Installation size 300 &#215; 230 (four holes)&lt;BR&gt;&lt;BR&gt;CKJ5-600 AC vacuum contactor external dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/20074218339422.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 267px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-600 AC vacuum contactor&quot; src=&quot;/uploadfiles/200704/20074218339422.jpg&quot; width=509 height=267&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ5-600 AC Vacuum Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-400 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/2220.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The CKJ5-400 AC vacuum contactor is suitable for feeding networks with AC 50HZ, rated voltage of 1140V, and rated current up to 400A. It is used for remote connection and disconnection of circuits, as well as frequent starting and stopping of AC motors. It is also suitable for assembly with various devices to form explosion-proof electromagnetic starting machines&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;Model CKJ5-400;&lt;BR&gt;Level: 3&lt;BR&gt;Rated voltage 1140 (V)&lt;BR&gt;Rated current 400 (A)&lt;BR&gt;Control voltage 36-110-127-220-380 (V)&lt;BR&gt;Main circuit connection capacity 4000A 100 times&lt;BR&gt;Main circuit breaking capacity 3200A 25 times&lt;BR&gt;Extreme breaking 4500A 3 times&lt;BR&gt;Electrical lifespan AC4 2 (10000 cycles)&lt;BR&gt;Mechanical lifespan of 3 million cycles&lt;BR&gt;Installation size 180 &#215; 160 (four holes)&lt;BR&gt;&lt;BR&gt;CKJ5-400 AC vacuum contactor external dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742183127165.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 275px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-400 AC vacuum contactor&quot; src=&quot;/uploadfiles/200704/200742183127165.jpg&quot; width=509 height=275&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ5-400 AC Vacuum Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-250 AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/2218.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CKJ5-250 AC vacuum contactor is suitable for feeding networks with AC 50Hz, rated voltage of 1140V, rated current up to 1140V, and rated current up to 250A. It is used for remote connection and disconnection of circuits, as well as frequent starting and stopping of AC motors, and is suitable for cooperation with various devices to form explosion-proof electromagnetic starting machines&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;Model CKJ5-250;&lt;BR&gt;Level: 3&lt;BR&gt;Rated voltage 1140 (V)&lt;BR&gt;Rated current 250 (A)&lt;BR&gt;Control voltage 36-110-127-220-380 (V)&lt;BR&gt;Main circuit connection capacity 2500A 100 times&lt;BR&gt;Main circuit breaking capacity 2000A 25 times&lt;BR&gt;Extreme breaking 4500A 3 times&lt;BR&gt;Electrical lifespan AC4 6 (10000 cycles)&lt;BR&gt;Mechanical lifespan of 3 million cycles&lt;BR&gt;Installation size 160 &#215; 160 (four holes)&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/20074218281705.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-250 AC vacuum contactor&quot; src=&quot;/uploadfiles/200704/20074218281705.jpg&quot; width=509 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ5-250 AC Vacuum Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-125( ¢ò) type AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/2216.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:42</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CKJ5-125 AC vacuum contactor is suitable for feeding networks with AC 50HZ, rated voltage of 1140V, and rated current of 125A. It is used for remote connection and disconnection of circuits, as well as frequent starting and stopping of AC motors. It is also suitable for assembly with various devices to form explosion-proof electromagnetic starting machines&lt;BR&gt;Technical Specifications&lt;BR&gt;Model CKJ5-125 (II);&lt;BR&gt;Level: 3&lt;BR&gt;Rated voltage 1140 (V)&lt;BR&gt;Rated current 125 (A)&lt;BR&gt;Control voltage 36-110-127-220-380 (V)&lt;BR&gt;Main circuit connection capacity 12500A 100 times&lt;BR&gt;Main circuit breaking capacity 1000A 25 times&lt;BR&gt;Extreme breaking 2500A 3 times&lt;BR&gt;Electrical lifespan AC4.6 (10000 cycles)&lt;BR&gt;Mechanical lifespan of 3 million cycles&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742182345571.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 256px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-125 (II) AC vacuum contactor&quot; src=&quot;/uploadfiles/200704/200742182345571.jpg&quot; width=509 height=256&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ5-125 (II) type AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-125(I) AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/2215.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:34</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The CKJ5-125 AC vacuum contactor is suitable for feeding networks with AC 50HZ, rated voltage of 1140V, and rated current of 125A. It is used for remote connection and disconnection of circuits, as well as frequent starting and stopping of AC motors. It is also suitable for assembly with various devices to form explosion-proof electromagnetic starting machines&lt;BR&gt;Technical Specifications&lt;BR&gt;Model CKJ5-125 (I);&lt;BR&gt;Level: 3&lt;BR&gt;Rated electrical pressure 1140 (V)&lt;BR&gt;Control voltage 36-110-127-220-380 (V)&lt;BR&gt;Main circuit connection capacity 11250A 100 times&lt;BR&gt;Extreme score determination 2500A 3 times&lt;BR&gt;Electrical lifespan AC46 (10000 cycles)&lt;BR&gt;Mechanical lifespan of 3 million cycles&lt;BR&gt;Installation size 150 &#215; 130 (four holes)&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742182158371.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 246px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-125 (I) type AC vacuum contactor&quot; src=&quot;/uploadfiles/200704/200742182158371.jpg&quot; width=509 height=246&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ5-125 (I) type AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]EVS160-630 series heavy-duty low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/1642.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:26</pubDate>
           <comments></comments>
           <description>The EVS160-630 series heavy-duty low-voltage vacuum contactor has the advantages of high connection and disconnection capacity, long electrical and mechanical life, and high reliability under harsh conditions. It is particularly suitable for use in basic industries, metallurgy, petroleum, chemical industry, mining, and ports. It is suitable for power systems with AC 50HZ/60Hz, rated operating voltage up to 1140V, and rated operating current up to 630A. It can be used to connect and disconnect circuits at long and short distances, as well as to frequently start and control AC motors under heavy task conditions. It can also be combined with various protective devices to form electromagnetic actuators.&lt;BR&gt;&lt;BR&gt;Usage conditions:&lt;BR&gt;(1) The normal working conditions of this contactor comply with GB/T14048.1-93 &quot;Low voltage switchgear and control equipment&quot;&lt;BR&gt;(2) Allowable ambient air temperature: -25 ¡æ -45 ¡æ&lt;BR&gt;(3) Relative humidity: At a temperature of 25 ¡æ, the maximum relative humidity can reach 90 &#176; C&lt;BR&gt;(4) Pollution level: Level 3&lt;BR&gt;(5) Altitude: not exceeding 2000 meters&lt;BR&gt;(6) Installation conditions: Vertically upward (with the drive mechanism on top), with the installation area tilted no more than 15 &#176; from the vertical plane&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177 align=middle&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P align=center&gt;EVS160&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;EVS250&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;EVS400&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;EVS630&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Rated working voltage Ue&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;1140V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;1140V&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;1140V&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;1140V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Rated working current Ie&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;160A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;250A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;400A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;630A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;50Hz/60Hz&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;50Hz/60Hz&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;50Hz/60Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Rated connection capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;1920A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;3000A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;4800A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;7560A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Rated breaking capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;1600A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;2500A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;4000A&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;6300A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;The maximum allowable power of the motor is 660V50Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;140KW&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;220KW&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;350KW&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;560KW&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Suction time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;30ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;30ms&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;30ms&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;release time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;20ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;20ms&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;15ms&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;15ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22 width=177&gt;
&lt;P align=left&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=4&gt;
&lt;P align=center&gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;P align=left&gt;Maximum operating frequency (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=4&gt;
&lt;P align=center&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;CENTER&gt;&lt;/CENTER&gt;
&lt;TR&gt;
&lt;TD height=4 width=177&gt;
&lt;P&gt;Electrical lifespan Ac2&lt;BR&gt;Ac3&lt;BR&gt;Ac4&lt;/P&gt;&lt;/TD&gt;
&lt;CENTER&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;3&#215;106&lt;BR&gt;5&#215;106&lt;BR&gt;0.12&#215;106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;2&#215;106&lt;BR&gt;5&#215;106&lt;BR&gt;0.08&#215;106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;2&#215;106&lt;BR&gt;5&#215;106&lt;BR&gt;0.08&#215;106&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88 align=middle&gt;
&lt;P&gt;1&#215;106&lt;BR&gt;3&#215;106&lt;BR&gt;0.06&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/CENTER&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;CENTER&gt;
&lt;TR&gt;
&lt;TD width=33&gt;model&lt;/TD&gt;
&lt;TD width=51&gt;EVS160&lt;/TD&gt;
&lt;TD width=50&gt;EVS250&lt;/TD&gt;
&lt;TD width=50&gt;EVS400&lt;/TD&gt;
&lt;TD width=50&gt;EVS630&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;A&lt;/TD&gt;
&lt;TD width=51&gt;one hundred and fifty-five&lt;/TD&gt;
&lt;TD width=50&gt;one hundred and fifty-five&lt;/TD&gt;
&lt;TD width=50&gt;two hundred&lt;/TD&gt;
&lt;TD width=50&gt;two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;B&lt;/TD&gt;
&lt;TD width=51&gt;three hundred&lt;/TD&gt;
&lt;TD width=50&gt;three hundred and ten&lt;/TD&gt;
&lt;TD width=50&gt;three hundred and thirty&lt;/TD&gt;
&lt;TD width=50&gt;three hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;C&lt;/TD&gt;
&lt;TD width=51&gt;two hundred and eighty&lt;/TD&gt;
&lt;TD width=50&gt;two hundred and eighty-five&lt;/TD&gt;
&lt;TD width=50&gt;three hundred and five&lt;/TD&gt;
&lt;TD width=50&gt;three hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;D&lt;/TD&gt;
&lt;TD width=51&gt;seventy-five&lt;/TD&gt;
&lt;TD width=50&gt;seventy-five&lt;/TD&gt;
&lt;TD width=50&gt;eighty-seven point five&lt;/TD&gt;
&lt;TD width=50&gt;eighty-seven point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;E&lt;/TD&gt;
&lt;TD width=51&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD width=50&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD width=50&gt;two hundred and sixty-two point five&lt;/TD&gt;
&lt;TD width=50&gt;two hundred and sixty-two point five&lt;/TD&gt;&lt;/TR&gt;&lt;/CENTER&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/200612310216133.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 228px; HEIGHT: 180px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of EVS160-630 series heavy-duty low-voltage vacuum contactor&quot; src=&quot;/uploadfiles/200612/200612310216133.jpg&quot; width=228 height=180&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;EVS160-630 series heavy-duty low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ(9)80-140 type low-voltage AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/1641.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:17</pubDate>
           <comments></comments>
           <description>The CKJ (9) 80-140 series low-voltage AC vacuum contactor is a three-stage coaxial linkage type, characterized by small size, light weight, good dust resistance, and strong versatility It is an ideal replacement product for low-voltage AC air contactors.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=79 align=middle&gt;
&lt;P align=center&gt;switch type&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=92 align=middle&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=96 align=middle&gt;
&lt;P align=center&gt;Rated heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=122 colSpan=2 align=middle&gt;
&lt;P align=center&gt;Service life (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=73 align=middle&gt;
&lt;P align=center&gt;Usage category&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=87 align=middle&gt;
&lt;P align=center&gt;rated operation&lt;/P&gt;
&lt;P align=center&gt;Current (A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61 align=middle&gt;
&lt;P&gt;mechanical&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67 align=middle&gt;
&lt;P&gt;electrical&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=79 align=middle&gt;
&lt;P align=center&gt;bolted connection&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;220V DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96 align=middle&gt;
&lt;P align=center&gt;6A&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61 align=middle&gt;
&lt;P&gt;&amp;gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=67 align=middle&gt;
&lt;P&gt;&amp;gt;2&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73 align=middle&gt;
&lt;P&gt;DC11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87 align=middle&gt;
&lt;P align=center&gt;0.4A DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=92 align=middle&gt;
&lt;P&gt;280V DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96 align=middle&gt;
&lt;P align=center&gt;6A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73 align=middle&gt;
&lt;P&gt;AC11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87 align=middle&gt;
&lt;P align=center&gt;4A AC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2 align=middle&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P align=center&gt;CKJ(9)80&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;CKJ(9)120&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;CKJ(9)140&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Rated working voltage Ue&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Rated working current Ie&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;80A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;120A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;140A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;rated power&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Rated connection capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;800A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;1200A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;1400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Rated breaking capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;640A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;960A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;1120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Suction time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;release time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=369 colSpan=3 align=middle&gt;
&lt;P&gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=28 width=177 colSpan=2&gt;
&lt;P&gt;Maximum operating frequency (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=28 width=369 colSpan=3 align=middle&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Electrical lifespan Cos &amp;oslash;=0.35 Ac2 Ac3 Ac4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;10&#215;105 4&#215;106 2&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;10&#215;105 3&#215;106 1.5&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P&gt;10&#215;105 2&#215;106 1&#215;105&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177 colSpan=2&gt;
&lt;P&gt;Operation control voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=369 colSpan=3 align=middle&gt;
&lt;P&gt;DC: 48V, 110V, 220V&lt;/P&gt;
&lt;P&gt;Communication: 220V, 380V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200612/200612395413295.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 291px; HEIGHT: 180px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ (9) 80-140 low-voltage AC vacuum contactor&quot; src=&quot;/uploadfiles/200612/200612395413295.jpg&quot; width=291 height=180&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ (9) 80-140 Low Voltage AC Vacuum Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ9 series vacuum AC contactor </title>
           <link>http://www.91way.com/info_en/1439.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:08</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1. Scope of application:&lt;BR&gt;&lt;BR&gt;The CKJ9 series vacuum AC contactor is suitable for use in power systems with an AC frequency of 50Hz, a rated working voltage of 1140V for the main circuit, and a rated working current of 160A. It is used for remote connection and disconnection of circuits, as well as frequent starting and control of AC motors. It is suitable for various protective devices to form electromagnetic starters, and is particularly suitable for applications such as coal mines, oil fields, and chemical industries.&lt;BR&gt;&lt;BR&gt;2. Model meaning:&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061114175633889.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 385px; HEIGHT: 181px&quot; border=0 hspace=0 alt=&quot;CKJ9 series vacuum AC contactor model description&quot; src=&quot;/uploadfiles/200611/20061114175633889.jpg&quot; width=385 height=181&gt;&lt;/A&gt;&lt;BR&gt;3. Product features:&lt;BR&gt;1. Adopting vacuum arc extinguishing, it is safe and reliable, with high breaking capacity, high operating frequency, and long service life.&lt;BR&gt;2. Equipped with auxiliary switches compatible with electronic devices, it has small size, light weight, and good dust resistance.&lt;BR&gt;&lt;BR&gt;4. Main technical parameters:&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061114175650282.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ9 series vacuum AC contactor&quot; src=&quot;/uploadfiles/200611/20061114175650282.jpg&quot; width=680 height=330&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;CKJ9 series vacuum AC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ3-2KV series vacuum contactor 800A 1000A 1250A</title>
           <link>http://www.91way.com/info_en/1426.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:26:00</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CKJ3 2KV series vacuum contactor&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;parameter&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=31&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;main&lt;/P&gt;
&lt;P&gt;electricity&lt;/P&gt;
&lt;P&gt;road&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated working voltage (Ue)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;2 kV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated working current (Ie)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;800£¬1000£¬1250&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated heating current (Ith)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;800£¬1000£¬1250&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated connection capacity (I)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;4Ie&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated breaking capacity (Ic)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;4Ie&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;50/60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=31&gt;
&lt;P&gt;control&lt;/P&gt;
&lt;P&gt;manufacture&lt;/P&gt;
&lt;P&gt;electricity&lt;/P&gt;
&lt;P&gt;road&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated voltage (Us) 1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;AC.220/380£¬DC.110/220&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=180&gt;
&lt;P&gt;Rated power (Ps)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Electricity maintenance&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;P align=center&gt;VA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;¡Û 1000/100 (suction/hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Mechanical Maintenance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;¡Û 900/600 (closing/opening)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=2&gt;
&lt;P align=center&gt;auxiliary circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;form&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;3a£«3b&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;rated value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;380V/AC.5A or DC.1A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=2&gt;
&lt;P align=center&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Long term or mechanical&lt;BR&gt;Maintaining type&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;P align=center&gt;Times/h&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;short-term&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;P&gt;Mechanical lifespan 2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;P&gt;Electrical lifespan&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;P align=center&gt;25(AC-2)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=568 colSpan=5&gt;
&lt;P&gt;Note 1: The rated control voltage can also be customized according to user needs;&lt;/P&gt;
&lt;P&gt;2: For mechanical retention types, the locking mechanism needs to be replaced every 300000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;P align=center&gt;Technical Requirements&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;parameter&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;P align=center&gt;power frequency&lt;/P&gt;
&lt;P align=center&gt;tolerance&lt;/P&gt;
&lt;P align=center&gt;voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=96&gt;
&lt;P align=center&gt;main circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Interphase and relative ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;four point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;vacuum interrupter gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Control circuit to ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;P align=center&gt;Auxiliary circuit to ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=43&gt;
&lt;P align=center&gt;mechanical&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;feature&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;closing time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=288 colSpan=2&gt;
&lt;P align=center&gt;Inherent opening time&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü 160 (electric hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü 60 (mechanical hold)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;Three phases in different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;P align=center&gt;Closing bounce&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;P align=center&gt;¡Ü10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;Outline drawing of CKJ3-2KV series vacuum contactor&lt;BR&gt;&lt;A href=&quot;/upload2011/201103/20110314205316432.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 450px&quot; border=0 hspace=0 alt=&quot;CKJ3-2KV series vacuum contactor installation dimensions&quot; src=&quot;/upload2011/201103/20110314205316432.gif&quot; width=680 height=450&gt;&lt;/A&gt;&lt;BR&gt;CKJ3-2KV series vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ4 series vacuum contactor CKJ4-125 250 400D/1140V</title>
           <link>http://www.91way.com/info_en/1425.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:52</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=7 width=31&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;main&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working voltage (Ue)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one point one four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working current (Ie)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;125£¬250£¬400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated heating current (Ith)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;125£¬250£¬400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated connection capacity (I)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;10Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated breaking capacity (Ic)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;8Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Ultimate breaking ability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;10Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;HZ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=31&gt;
&lt;DIV&gt;control&lt;/DIV&gt;
&lt;DIV&gt;manufacture&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated voltage (Us) 1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;AC.220/380£¬DC.110/220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=180&gt;
&lt;DIV&gt;Rated power (Ps)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Electricity maintenance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Û 1000/100 (suction/hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;auxiliary circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;form&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;3a£«3b&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;rated value&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;380V/AC.5A or DC.1A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;Rated operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;long-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Times/h&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;short-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=3&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=3&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;25(AC-3)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=568 colSpan=5&gt;
&lt;DIV&gt;Note: The rated control voltage can also be customized according to user needs.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;DIV align=center&gt;Technical Requirements&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;DIV align=center&gt;power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=96&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Interphase and relative ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;vacuum interrupter gap&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Control circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Auxiliary circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;DIV align=center&gt;mechanical&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;feature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Inherent opening time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Three phases in different periods&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Closing bounce&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;CKJ4 series vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ3 series vacuum contactor CKJ3-800 1000 1250D/1140V</title>
           <link>http://www.91way.com/info_en/1424.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:43</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=6 width=31&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;main&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working voltage (Ue)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1.14£¨2 kV£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working current (Ie)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;800£¬1000£¬1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated heating current (Ith)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;800£¬1000£¬1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated connection capacity (I)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;4Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated breaking capacity (Ic)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;4Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;HZ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=3 width=31&gt;
&lt;DIV&gt;control&lt;/DIV&gt;
&lt;DIV&gt;manufacture&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=2&gt;
&lt;DIV&gt;Rated voltage (Us) 1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;AC.220/380£¬DC.110/220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=180&gt;
&lt;DIV&gt;Rated power (Ps)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Electricity maintenance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Û 1000/100 (suction/hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Mechanical Maintenance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Û 900/600 (closing/opening)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;auxiliary circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;form&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;3a£«3b&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;rated value&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;380V/AC.5A or DC.1A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;Rated operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Long term or mechanical maintenance type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Times/h&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;short-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=3&gt;
&lt;DIV&gt;Mechanical lifespan 2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=3&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;25(AC-2)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=568 colSpan=5&gt;
&lt;DIV&gt;Note 1: The rated control voltage can also be customized according to user needs;&lt;/DIV&gt;
&lt;DIV&gt;2: For mechanical retention types, the locking mechanism needs to be replaced every 300000 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;DIV align=center&gt;Technical Requirements&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;DIV align=center&gt;power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=96&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Interphase and relative ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;vacuum interrupter gap&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Control circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Auxiliary circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=43&gt;
&lt;DIV align=center&gt;mechanical&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;feature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Inherent opening time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü 160 (electric hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü 60 (mechanical hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Three phases in different periods&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Closing bounce&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/2006111485216271.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 530px&quot; border=0 hspace=0 alt=&quot;CKJ3 series vacuum contactor installation dimensions&quot; src=&quot;/uploadfiles/200611/2006111485216271.gif&quot; width=680 height=530&gt;&lt;/A&gt;&lt;BR&gt;CKJ3 series vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ2 series vacuum contactor CKJ2-800  1000  1250 1600A/1140V</title>
           <link>http://www.91way.com/info_en/1423.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:35</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=4&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=6 width=31&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;main&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated working voltage (Ue)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one point one four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated working current (Ie)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;800£¬1000£¬1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated heating current (Ith)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;800£¬1000£¬1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated connection capacity (I)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;4Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated breaking capacity (Ic)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;4Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;HZ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=3 width=31&gt;
&lt;DIV&gt;control&lt;/DIV&gt;
&lt;DIV&gt;manufacture&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=312 colSpan=3&gt;
&lt;DIV&gt;Rated voltage (Us) 1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;AC.220/380£¬DC.110/220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=96&gt;
&lt;DIV&gt;rated power&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=216 colSpan=2&gt;
&lt;DIV&gt;pickup&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Ü100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=216 colSpan=2&gt;
&lt;DIV&gt;maintain&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Ü100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=3&gt;
&lt;DIV&gt;auxiliary circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;form&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;3a£«3b&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;rated value&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;380V/AC.5A or DC.1A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 width=211 colSpan=3&gt;
&lt;DIV&gt;Rated operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;long-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Times/h&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;short-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=4&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=343 colSpan=4&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50(AC-2)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=568 colSpan=6&gt;
&lt;DIV&gt;*Note: The rated control voltage can also be customized according to user needs.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;DIV align=center&gt;Technical Requirements&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;DIV align=center&gt;power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=96&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Interphase and relative ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;vacuum interrupter gap&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Control circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Auxiliary circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;DIV align=center&gt;mechanical&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;feature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Inherent opening time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü 160 (electric hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Three phases in different periods&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Closing bounce&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/2006111484834638.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 470px&quot; border=0 hspace=0 alt=&quot;CKJ2 series vacuum contactor installation dimensions&quot; src=&quot;/uploadfiles/200611/2006111484834638.gif&quot; width=680 height=470&gt;&lt;/A&gt;&lt;BR&gt;CKJ2 series vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ1-125A~160A/1140V Vacuum contactor </title>
           <link>http://www.91way.com/info_en/1422.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:26</pubDate>
           <comments></comments>
           <description>CKJ1-125A~160A/1140V vacuum contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ13 series low-voltage vacuum contactor 1140V</title>
           <link>http://www.91way.com/info_en/1409.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:18</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Technical Specifications&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;data&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=13 width=16&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=138 colSpan=3&gt;
&lt;DIV&gt;Technical Specifications&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV&gt;data&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;unit&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=6 width=31&gt;
&lt;DIV&gt;main circuit&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;one thousand one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=138 colSpan=3&gt;
&lt;DIV&gt;Number of poles in the main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;extreme&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=3 width=54&gt;
&lt;DIV&gt;control loop&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=84 colSpan=2&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV&gt;110,&lt;/DIV&gt;
&lt;DIV&gt;220£¬380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;Connection capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;6.3/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;A/time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=2 width=36&gt;
&lt;DIV&gt;rated power&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=48&gt;
&lt;DIV&gt;pickup&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV&gt;¡Ü600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;breaking capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;5/50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;A/time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=48&gt;
&lt;DIV&gt;maintain&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV&gt;¡Ü50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;Ultimate breaking ability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;6.3/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;A/time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=5 width=54&gt;
&lt;DIV&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=5 width=156 colSpan=3&gt;
&lt;DIV&gt;240&#215;182&#215;182&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=5 width=45&gt;
&lt;DIV&gt;mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;50/60&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Electrical lifespan AC3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Electrical lifespan AC4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Rated operating frequency AC3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=54&gt;
&lt;DIV&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=156 colSpan=3&gt;
&lt;DIV&gt;160&#215;160&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Rated operating frequency AC4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=54&gt;
&lt;DIV&gt;weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=156 colSpan=3&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=45&gt;
&lt;DIV&gt;kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=127 colSpan=2&gt;
&lt;DIV&gt;Short term operating frequency of 20S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=50&gt;
&lt;DIV&gt;times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=255 colSpan=5&gt;
&lt;DIV&gt;Note: The rated voltage of the control circuit can be customized according to user needs.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CKJ13 series low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CK11 series low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/1408.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:10</pubDate>
           <comments></comments>
           <description>CK11 series low-voltage vacuum contactor&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ7 High current series vacuum contactor </title>
           <link>http://www.91way.com/info_en/1363.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:25:02</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CKJ7 high current series vacuum contactor:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=31&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;main&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working voltage (Ue)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1.14,2&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated working current (Ie)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1600£¬2000£¬2500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated heating current (Ith)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1600£¬2000£¬2500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated connection capacity (I)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1.5Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated breaking capacity (Ic)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;1.5Ie&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=31&gt;
&lt;DIV&gt;control&lt;/DIV&gt;
&lt;DIV&gt;manufacture&lt;/DIV&gt;
&lt;DIV&gt;electricity&lt;/DIV&gt;
&lt;DIV&gt;road&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;DIV&gt;Rated voltage (Us) 1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;AC.or DC.110/220/380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=180&gt;
&lt;DIV&gt;Rated power (Ps)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Electricity maintenance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Û 1000/100 (suction/hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Mechanical Maintenance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;¡Û 900/600 (closing/opening)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;auxiliary circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;form&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;3a£«3b&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;rated value&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;380V/AC.5A or DC.1A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=2&gt;
&lt;DIV&gt;Rated operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Long term or mechanical maintenance type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Times/h&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;short-term&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;DIV&gt;Mechanical lifespan 2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 colSpan=3&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV align=center&gt;50(AC-1)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=568 colSpan=5&gt;
&lt;DIV&gt;Note 1: The rated control voltage can also be customized according to user needs;&lt;/DIV&gt;
&lt;DIV&gt;2: For mechanical retention types, the locking mechanism needs to be replaced every 100000 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=331 colSpan=3&gt;
&lt;DIV align=center&gt;Technical Requirements&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=43&gt;
&lt;DIV align=center&gt;power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=96&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;Interphase and relative ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV align=center&gt;vacuum interrupter gap&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Secondary circuit to ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;2 (excluding semiconductors and resistive capacitive components)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=43&gt;
&lt;DIV align=center&gt;mechanical&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;feature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Inherent opening time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü 160 (electric hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü 60 (mechanical hold)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Three phases in different periods&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=288 colSpan=2&gt;
&lt;DIV align=center&gt;Closing bounce&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=189&gt;
&lt;DIV align=center&gt;¡Ü10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;DIV align=left&gt;CKJ7 high current series installation dimensions&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200910/2009102482226791.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 440px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ7 high current series vacuum contactor&quot; src=&quot;/upload2009/200910/2009102482226791.gif&quot; width=680 height=440&gt;&lt;/A&gt;&lt;BR&gt;CKJ7 High Current Series Vacuum Contactor&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ20 series AC vacuum contactor </title>
           <link>http://www.91way.com/info_en/746.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:24:53</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061028111928640.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 900px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CKJ20 series AC vacuum contactor&quot; src=&quot;/uploadfiles/200610/20061028111928640.jpg&quot; width=680 height=900&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ20 series AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ10-1.2KV series single pole low-voltage vacuum contactor </title>
           <link>http://www.91way.com/info_en/745.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:24:45</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CKJ10-1.2KV series single pole low-voltage vacuum contactor has the advantages of strong breaking capacity, non aging contacts, non exposed arc, safety and reliability, long service life, maintenance free, and low noise. Its excellent breaking technology can be frequently operated and used under particularly harsh conditions.&lt;BR&gt;Suitable for occasions that require single-phase control and protection. Widely used in the fields of street lamp control and single-phase electrical control. It can completely replace traditional electrical appliances and has economic viability.&lt;BR&gt;&lt;BR&gt;Main performance parameters&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Performance parameter model parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;CKJ£­160/1140&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Rated closing capacity (A/100 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Rated breaking capacity (A/25 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;one thousand two hundred and eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Ultimate breaking capacity (A/3 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan AC3 (10000 cycles)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Mechanical lifespan (10000 cycles)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating frequency (times/h)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term operation frequency times/h (20S)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;110, 220, 380 or customized&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Control power&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;100/8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Auxiliary contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;Open AC380/3A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Contact opening distance (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;1.5&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Overtravel (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=159&gt;
&lt;P&gt;Weight (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P&gt;one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/2006102810458623.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 338px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ10-1.2KV series single pole low voltage vacuum contactor&quot; src=&quot;/uploadfiles/200610/2006102810458623.jpg&quot; width=535 height=338&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CKJ10-1.2KV series single pole low voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5-2KV series high current vacuum contactor </title>
           <link>http://www.91way.com/info_en/744.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:24:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CKJ5-2KV series high current vacuum contactor features:&lt;BR&gt;&lt;BR&gt;Fully insulated modular architecture, unique and compact structure, beautiful appearance, and small volume.&lt;BR&gt;Can form unipolar, bipolar, tri polar, and multipole products.&lt;BR&gt;Unique dual dynamic end connection and dual circuit soft connection, more reliable dynamic end connection, large conductive cross-section, and low contact resistance.&lt;BR&gt;Three pole and multi pole use 10A enclosed auxiliary switches for more reliable use.&lt;BR&gt;The position of the control terminal can be set according to user requirements for easy wiring.&lt;BR&gt;Equipped with dedicated installation bolts for easy installation.&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;Main performance parameters of CKJ5-2KV series high current vacuum contactor&lt;/P&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Performance parameter, current parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;1000A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;1250A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;1600A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;2000A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Rated working voltage (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Rated connection capacity (A/100 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;six thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;eight thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Rated breaking capacity (A/25 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;four thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;six thousand and four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eight thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Ultimate breaking capacity (A/3 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;six thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;eight thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Fracture frequency withstand voltage (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Inter phase ground frequency withstand voltage (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Main circuit contact resistance (¦Ì ¦¸)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;¡Ü 150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;¡Ü 150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;¡Ü 150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;¡Ü 150&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Rated operating frequency (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Mechanical lifespan (10000 cycles)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Electrical lifespan (10000 cycles)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Contact terminal pressure (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;&amp;gt;300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;&amp;gt;300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;&amp;gt;350&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;&amp;gt;350&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Contact opening distance (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;2.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;2.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;2.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;2.5+0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Overtravel (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;1.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;1.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;1.5+0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;1.5+0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=164&gt;
&lt;P&gt;Weight (Two/Three poles) (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;15/22&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;P align=center&gt;16/23&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;16/23&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;16/23&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;P&gt;Control and auxiliary circuits&lt;BR&gt;a. Control voltage Ua: AC or DC 110V, 220V, 380V, or customized according to user requirements.&lt;BR&gt;b. Control power: Start&amp;lt;900W and maintain&amp;lt;30W&lt;BR&gt;c. Auxiliary contacts: single pole: two normally open and one normally closed; Two poles: a single auxiliary switch is two normally open and one normally closed, and a dual auxiliary switch is four normally open and three normally closed; Triple pole: The single auxiliary switch is three normally open and two normally closed, while the dual auxiliary switch is six normally open and five normally closed, with a maximum of ten normally open and nine normally closed.&lt;BR&gt;d. Contact capacity: Single pole and dual pole AC380V 5A; Three pole AC380V 10A.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061028103755863.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 1000px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ5-2KV series high current vacuum contactor&quot; src=&quot;/uploadfiles/200610/20061028103755863.jpg&quot; width=680 height=1000&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061028104024141.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 682px; HEIGHT: 805px&quot; border=0 hspace=0 alt=&quot;CKJ5-2KV series high current vacuum contactor external dimensions&quot; src=&quot;/uploadfiles/200610/20061028104024141.jpg&quot; width=682 height=805&gt;&lt;/A&gt;&lt;BR&gt;CKJ5-2KV series high current vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ(9) type low-voltage vacuum contactor 80A  120A 140A</title>
           <link>http://www.91way.com/info_en/594.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:24:28</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 291px; HEIGHT: 180px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CKJ (9) type low-voltage vacuum contactor&quot; src=&quot;/uploadfiles/200610/2006102712449565.jpg&quot; width=291 height=180&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=63 rowSpan=2 width=79 align=middle&gt;
&lt;P align=center&gt;switch type&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=63 rowSpan=2 width=92 align=middle&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=63 rowSpan=2 width=96 align=middle&gt;
&lt;P align=center&gt;Rated heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=122 colSpan=2 align=middle&gt;
&lt;P align=center&gt;Service life (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=63 rowSpan=2 width=73 align=middle&gt;
&lt;P align=center&gt;Usage category&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=63 rowSpan=2 width=87 align=middle&gt;
&lt;P align=center&gt;rated operation&lt;/P&gt;
&lt;P align=center&gt;Current (A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=29 width=61 align=middle&gt;
&lt;P&gt;mechanical&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=29 width=67 align=middle&gt;
&lt;P&gt;electrical&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=46 rowSpan=2 width=79 align=middle&gt;
&lt;P align=center&gt;bolted connection&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=92 align=middle&gt;
&lt;P&gt;220V DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=96 align=middle&gt;
&lt;P align=center&gt;6A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=46 rowSpan=2 width=61 align=middle&gt;
&lt;P&gt;&amp;gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=46 rowSpan=2 width=67 align=middle&gt;
&lt;P&gt;&amp;gt;2&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=73 align=middle&gt;
&lt;P&gt;DC11&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=87 align=middle&gt;
&lt;P align=center&gt;0.4A DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=21 width=92 align=middle&gt;
&lt;P&gt;280V DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=96 align=middle&gt;
&lt;P align=center&gt;6A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=73 align=middle&gt;
&lt;P&gt;AC11&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=87 align=middle&gt;
&lt;P align=center&gt;4A AC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=21 width=177 colSpan=2 align=middle&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=125 align=middle&gt;
&lt;P align=center&gt;CKJ(9)80&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=125 align=middle&gt;
&lt;P&gt;CKJ(9)120&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=125 align=middle&gt;
&lt;P&gt;CKJ(9)140&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=177 colSpan=2&gt;
&lt;P&gt;Rated working voltage Ue&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;660V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=177 colSpan=2&gt;
&lt;P&gt;Rated working current Ie&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;80A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;120A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;140A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=177 colSpan=2&gt;
&lt;P&gt;rated power&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;50Hz/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17 width=177 colSpan=2&gt;
&lt;P&gt;Rated connection capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;800A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;1200A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;1400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17 width=177 colSpan=2&gt;
&lt;P&gt;Rated breaking capacity Cos &amp;oslash;=0.35&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;640A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;960A&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 width=125 align=middle&gt;
&lt;P&gt;1120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=177 colSpan=2&gt;
&lt;P&gt;Suction time&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 width=125 align=middle&gt;
&lt;P&gt;45ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=9 width=177 colSpan=2&gt;
&lt;P&gt;release time&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 width=125 align=middle&gt;
&lt;P&gt;30ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=1 width=177 colSpan=2&gt;
&lt;P&gt;Mechanical lifespan (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=1 width=369 colSpan=3 align=middle&gt;
&lt;P&gt;5&#215;106&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=28 width=177 colSpan=2&gt;
&lt;P&gt;Maximum operating frequency (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=28 width=369 colSpan=3 align=middle&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=1 width=177 colSpan=2&gt;
&lt;P&gt;Electrical lifespan Cos &amp;oslash;=0.35 Ac2 Ac3 Ac4&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=1 width=125 align=middle&gt;
&lt;P&gt;10&#215;105 4&#215;106 2&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=1 width=125 align=middle&gt;
&lt;P&gt;10&#215;105 3&#215;106 1.5&#215;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=125 align=middle&gt;
&lt;P bgcolor=&quot;#BDFBF1&quot;&gt;10&#215;105 2&#215;106 1&#215;105&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=1 width=177 colSpan=2&gt;
&lt;P&gt;Operation control voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=1 width=369 colSpan=3 align=middle&gt;
&lt;P align=center&gt;DC: 48V, 110V, 220V&lt;BR&gt;Communication: 220V, 380V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;CKJ (9) type low-voltage vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low voltage vacuum contactor]CKJ5 series AC vacuum contactor 63A 80A 125A 160A  250A 400A  600A  800A  1000A  1250A</title>
           <link>http://www.91way.com/info_en/593.html</link>
           <author></author>
           <guid></guid>
           <category>Low voltage vacuum contactor</category>
           <pubDate>2026-6-10 11:24:20</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 322px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CKJ5 series AC vacuum contactor&quot; src=&quot;/uploadfiles/200610/20061027113852765.gif&quot; width=350 height=322&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 466px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor installation dimensions&quot; src=&quot;/uploadfiles/200610/2006102711391189.gif&quot; width=466 height=310&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 460px; HEIGHT: 315px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor series parameters&quot; src=&quot;/uploadfiles/200610/20061027113910951.gif&quot; width=460 height=315&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 459px; HEIGHT: 308px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor external dimensions&quot; src=&quot;/uploadfiles/200610/20061027113920436.gif&quot; width=459 height=308&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 232px; HEIGHT: 103px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor model description&quot; src=&quot;/uploadfiles/200610/20061027113930717.gif&quot; width=232 height=103&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 464px; HEIGHT: 319px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor current rating&quot; src=&quot;/uploadfiles/200610/20061027113938462.gif&quot; width=464 height=319&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 462px; HEIGHT: 306px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor external dimension drawing 1&quot; src=&quot;/uploadfiles/200610/20061027113949983.gif&quot; width=462 height=306&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 458px; HEIGHT: 317px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor external dimension drawing 2&quot; src=&quot;/uploadfiles/200610/20061027113959637.gif&quot; width=458 height=317&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 458px; HEIGHT: 317px&quot; border=0 hspace=0 alt=&quot;CKJ5 series AC vacuum contactor external dimensions 3&quot; src=&quot;/uploadfiles/200610/20061027114010706.gif&quot; width=458 height=317&gt;&lt;BR&gt;&lt;BR&gt;CKJ5 series AC vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZH-1200/20 Reverse Distribution DC Contactor </title>
           <link>http://www.91way.com/info_en/24246.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:23:15</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212185519632.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 510px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions and structural diagram of CZH-1200/20 reverse distribution DC contactor&quot; src=&quot;/upload2013/201312/20131212185519632.jpg&quot; width=680 height=510&gt;&lt;/A&gt;&lt;BR&gt;CZH-1200/20 Reverse Distribution DC Contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-70F(7612) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29364.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:22:41</pubDate>
           <comments></comments>
           <description>Product Name: JQ-70F High Power DC Contactor (7612)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c, 5000 cycles&lt;BR&gt;Product size: 105mm * 65mm * 92mm&lt;BR&gt;Product weight: ¡Ü 900g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-70F high-power DC contactor (7612) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG0725-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7672F type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29365.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:22:20</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7672F High Power DC Contactor (7672)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c., 2 * 10 ^ 4 times&lt;BR&gt;Product size: 97mm * 65mm * 43mm&lt;BR&gt;Product weight: ¡Ü 320g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7672F high-power DC contactor (7672) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20998-2013.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7651F type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29366.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:22:00</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7651F High Power DC Contactor (7651)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Va. c., 28Vd. c&lt;BR&gt;Product size: 121mm * 70mm * 52.5mm&lt;BR&gt;Product weight: ¡Ü 650g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7651F high-power DC contactor (7651) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20947-2013. 4. Can be used interchangeably with the 2500A0 contactor.</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7659F High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29367.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:21:35</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7659F High Voltage Contactor (7659)&lt;BR&gt;Product specifications: 012Vd. c., 024Vd. c&lt;BR&gt;Load: 400Vd. c.. 1 * 10 ^ 4&lt;BR&gt;Product size: 111.3mm * 60mm * 74.7mm&lt;BR&gt;Product weight: ¡Ü 750g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. JQ-7659F high-voltage DC contactor (7659) has high load voltage and high load current, mainly used for switching circuits in high load DC high-voltage systems. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21033-2013. 4. Can be used interchangeably with AE19024 products.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-76F(7609) High Power High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29368.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:21:09</pubDate>
           <comments></comments>
           <description>Product Name: JQ-76F High Power High Voltage Contactor (7609)&lt;BR&gt;Product specifications: A, D, J&lt;BR&gt;Load: 270Vd. c, 1 * 10 ^ 4 times&lt;BR&gt;Product size: 80.5mm * 65.6mm * 72.3mm&lt;BR&gt;Product weight: ¡Ü 430g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-76F high-power high-voltage DC contactor (7609) has a large load and high switching voltage, and can be widely used for circuit switching in aerospace, aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;.</description>
       </item>
       <item>
           <title>[DC contactor]JQ-65F(7603) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29370.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:20:39</pubDate>
           <comments></comments>
           <description>Product Name: JQ-65F High Power DC Contactor (7603)&lt;BR&gt;Product specifications: 028Vd. c, 028AVd. c&lt;BR&gt;Load: 28Vd. c.3 * 10 ^ 4 times&lt;BR&gt;Product size: 96mm * 65mm * 42mm&lt;BR&gt;Product weight: ¡Ü 300g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-65F high-power DC contactor (7603) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20660-2010. 4. Can be used interchangeably with the 2520 model.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7670 type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29373.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:20:12</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7670 High Power DC Contactor (7670)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c, 2 * 10 ^ 4 times&lt;BR&gt;Product size: 87mm * 34mm * 85mm&lt;BR&gt;Product weight: ¡Ü 400g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7670 high-power DC contactor (7670) is a high-power DC contactor with a main contact load current of 200A. It has the characteristics of multiple contact groups, high load, and long service life. Widely used in aviation, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21019-2013. 4. Can be used interchangeably with 414CC01.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-74F(7608) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29377.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:19:45</pubDate>
           <comments></comments>
           <description>Product Name: JQ-74F High Power DC Contactor (7608)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c, 1 * 10 ^ 4 times&lt;BR&gt;Product size: 100mm * 58mm * 60mm&lt;BR&gt;Product weight: ¡Ü 480g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-74F high-power DC contactor (7608) has the characteristics of high load, long service life, and strong environmental adaptability, and can be used in high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20695-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-67F(7606) type high-power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29363.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:19:08</pubDate>
           <comments></comments>
           <description>Product Name: JQ-67F High Power DC Electromagnetic Contactor (7606)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 27Vd. c, 50 cycles&lt;BR&gt;Product size: 85.5mm * 56mm * 83.5mm&lt;BR&gt;Product weight: ¡Ü 480g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-67F high-power DC electromagnetic contactor (7606) has strong load capacity and can be widely used in ship or ground switching circuits. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20668-2010.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7649F type maximum speed contactor (7649)) </title>
           <link>http://www.91way.com/info_en/29379.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:18:25</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7649F Maximum Rotation Relay (7649)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c, 2 * 10 ^ 4 times&lt;BR&gt;Product size: 105mm * 66mm * 86mm&lt;BR&gt;Product weight: ¡Ü 1200g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7649F maximum speed contactor (7649) is mainly used for switching circuits in aviation, aerospace, shipbuilding and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20909-2012. 4. Can replace PMO-16 contactor.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-77M(7627) type high-power electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29380.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:17:08</pubDate>
           <comments></comments>
           <description>Product Name: JQ-77M High Power Electromagnetic Contactor (7627)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c&lt;BR&gt;Product size: 63.5mm * 63.5mm * 79.5mm&lt;BR&gt;Product weight: ¡Ü 480g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-77M high-power electromagnetic contactor (7627) is a balanced force structure with three sets of conversion main contacts and one set of conversion auxiliary contacts. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG2010-2013&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-70FZ(7612Z) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29361.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:16:05</pubDate>
           <comments></comments>
           <description>Product Name: JQ-70FZ High Power DC Contactor (7612Z)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28V. d.c, 5000 cycles&lt;BR&gt;Product size: 105mm * 65mm * 135mm&lt;BR&gt;Product weight: ¡Ü 1800g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-70FZ high-power DC contactor (7612Z) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21027-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-71F(7613) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29360.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:14:23</pubDate>
           <comments></comments>
           <description>Product Name: JQ-71F High Power DC Contactor (7613)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c, 5 * 10 ^ 3 times&lt;BR&gt;Product size: 126mm * 78mm * 100mm&lt;BR&gt;Product weight: ¡Ü 1250g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-71F high-power DC contactor (7613) has the characteristics of high load, small size, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies in general occasions. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-66F High power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29385.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:12:32</pubDate>
           <comments></comments>
           <description>Product Name: JQ-66F High Power DC Electromagnetic Contactor (7604)&lt;BR&gt;Product specifications: 012Vd. c, 024Vd. c, 027Vd. c&lt;BR&gt;Load: 27Vd. c.2 * 10 ^ 4 times&lt;BR&gt;Product size: 56mm * 38.5mm * 54mm&lt;BR&gt;Product weight: ¡Ü 200g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-66F high-power DC electromagnetic contactor (7604) has the characteristics of strong load switching ability and strong environmental adaptability, and can be widely used for switching circuits in vehicles, ships, or ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG20666-2010&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7616FA High power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29393.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:12:04</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7616FA High Power DC Electromagnetic Contactor (7616A)&lt;BR&gt;Product specifications: 012Vd. c., 024Vd. c., 027Vd. c&lt;BR&gt;Load: 27Vd. c, 1.5 * 10 ^ 4 times&lt;BR&gt;Product size: 40mm * 30mm * 49mm&lt;BR&gt;Product weight: ¡Ü 120g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7616FA high-power DC electromagnetic contactor (7616A) has the characteristics of large load margin and strong environmental adaptability. 2. Complies with GJB2888-1997 &quot;General Specification for Power type Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20731A-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-63F(7605) type high-power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29356.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:11:20</pubDate>
           <comments></comments>
           <description>Product Name: JQ-63F High Power DC Electromagnetic Contactor (7605)&lt;BR&gt;Product specifications: 012Vd. c, 024Vd. c, 027Vd. c&lt;BR&gt;Load: 27Vd. c.2 * 10 ^ 4 times&lt;BR&gt;Product size: 70mm * 42.5mm * 68mm&lt;BR&gt;Product weight: ¡Ü 300g&lt;BR&gt;&lt;BR&gt;The JQ-63F high-power DC electromagnetic contactor (7605) has the characteristics of large load capacity and strong environmental adaptability, and can be widely used for switching circuits in vehicles, ships, or ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG20667-2010&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-QY5F,JQ-QY25F High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29448.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:11:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY5F, JQ-QY25F High Voltage DC Contactors&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817102827360.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY5F and JQ-QY25F high-voltage DC contactors&quot; src=&quot;/upload2025/202508/20250817102827360.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H600HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29447.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:11:11</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H600HFB High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817102604974.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H600HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102604974.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H400HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29446.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:11:03</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H400HF High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817102405448.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H400HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102405448.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H200HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29445.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H200HFA High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817102040864.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H200HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102040864.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H100HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29444.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H100HFB High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817101352972.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H100HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817101352972.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7655F High power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29376.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:42</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7655F High Power DC Electromagnetic Contactor (7655)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 60Vd. c., 115Va. c., 220Va. c., 380Va. c., 28Vd. c&lt;BR&gt;Product size: 123mm * 105mm * 85mm&lt;BR&gt;Product weight: ¡Ü 1350g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7655F high-power DC electromagnetic contactor (7655) has the characteristics of multiple contact groups, high load, long service life, and strong environmental adaptability. It is used for switching circuits in equipment in aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20959-2013.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H600HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29443.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H600HF High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817101222585.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H600HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817101222585.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H400HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29442.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:31</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H400HFA High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817100141384.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H400HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817100141384.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H300HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29441.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H300HFA High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817095947856.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H300HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095947856.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H200HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29440.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H200HFB High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817095803548.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H200HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095803548.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H100HF,JCQ-1H100HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29439.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:10:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H100HF, JCQ-1H100HFA High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817095526901.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;JCQ-1H100HF, JCQ-1H100HFA High Voltage DC Contactor Technical Parameters&quot; src=&quot;/upload2025/202508/20250817095526901.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H50HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29438.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:09:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H50HF High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817095109596.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H50HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095109596.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H20HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29437.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:09:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1H20HF High Voltage DC Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250817094925109.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1H20HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817094925109.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7639 type contactor (7639)}) </title>
           <link>http://www.91way.com/info_en/29362.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:07:46</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7639 Contactor (7639)&lt;BR&gt;Product specifications: 024Vd. c., 027Vd. c., 048Vd. c&lt;BR&gt;Load: 27Vd. c, 1.5 * 10 ^ 4 times&lt;BR&gt;Product size: 104.5mm * 65mm * 101mm&lt;BR&gt;Product weight: ¡Ü 1000g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7639 contactor (7639) has a set of bridge type dynamic closing main contacts and a set of bridge type dynamic breaking auxiliary contacts. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20749-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7640F type contactor (7640)}) </title>
           <link>http://www.91way.com/info_en/29359.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:07:21</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7640F Contactor (7640)&lt;BR&gt;Product specifications: 027Vd. c., 027AVd.c&lt;BR&gt;Load: 28Vd. c, 1.5 * 10 ^ 4 times&lt;BR&gt;Product size: 131mm * 80mm * 120.5mm&lt;BR&gt;Product weight: ¡Ü 1650g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7640F contactor (7640) has a set of bridge type dynamic contact points, with a contact load current of 600A. It has the characteristics of simple structure, large load design margin, and high reliability, and can be applied to general ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20750-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7664F type DC contactor (7664)} </title>
           <link>http://www.91way.com/info_en/29358.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:07:13</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7664F DC Contactor (7664)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c, 115/200Va. c&lt;BR&gt;Product size: 81mm * 48mm * 36mm&lt;BR&gt;Product weight: ¡Ü 250g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7664F DC contactor (7664) is a high-power contactor with a load current of 100A. It has the characteristics of small size, long service life, and strong environmental adaptability. Widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20963-2013. 4. Can be used interchangeably with 101CC01.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY1 series DC contactor </title>
           <link>http://www.91way.com/info_en/28034.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:56</pubDate>
           <comments></comments>
           <description>1¡¢ Purpose:&lt;BR&gt;Suitable for long-distance connection and disconnection of DC circuits and frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121150840338.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 412px; HEIGHT: 263px&quot; border=0 hspace=0 alt=&quot;CZY1 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121150840338.jpg&quot; width=412 height=263&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Installation and usage conditions&lt;BR&gt;1. The altitude of the installation location shall not exceed 2000m (special instructions shall be provided when ordering in high-altitude areas);&lt;BR&gt;2. The ambient air temperature ranges from -25 ¡æ to+40 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the heavy surface is less than &#177; 22.5 (as shown in the figure). When there is significant vibration on site, it is recommended to install in the direction of direct vibration to prevent vibration absorption;&lt;BR&gt;4. The contactor used in the quick release spring mechanism should be installed strictly in the direction shown in the diagram, while considering the shock resistance of the installation screws;&lt;BR&gt;5. Installed in an environment that is resistant to rain, snow, wind, and sand.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY1-C series instantaneous working DC contactor </title>
           <link>http://www.91way.com/info_en/28033.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;CZY1-C (for electromagnetic and permanent magnet mechanisms) instantaneous working DC contactor (zhuanli technology) is suitable for electromagnetic operating mechanisms with rated voltage up to DC 220V, used for long-distance instantaneous connection and disconnection of high-voltage circuit breakers. Because the coil is immediately cut off after the circuit breaker is activated, the coil is designed for instantaneous working.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121150050717.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=0 hspace=0 alt=&quot;CZY1-C series instantaneous working DC contactor model description&quot; src=&quot;/upload2024/202411/20241121150050717.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Installation and usage conditions&lt;BR&gt;1. The altitude of the installation location shall not exceed 2000m (special instructions shall be provided when ordering in high-altitude areas);&lt;BR&gt;2. The ambient air temperature ranges from -25 ¡æ to+40 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent accidental suction caused by vibration;&lt;BR&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121150114576.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 439px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZY1-C series instantaneous working DC contactor&quot; src=&quot;/upload2024/202411/20241121150114576.jpg&quot; width=680 height=439&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY2-63C,100C series DC contactor </title>
           <link>http://www.91way.com/info_en/28032.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;The CZY2-63C and -100C series DC contactors are suitable for electromagnetic operating mechanisms with rated voltage up to 220V DC, used for long-distance instantaneous connection and disconnection of high-voltage circuit breakers.&lt;BR&gt;Compared with CZY1, it has good anti vibration performance and beautiful appearance.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2024/202411/20241121145728367.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 648px; HEIGHT: 195px&quot; border=0 hspace=0 alt=&quot;Model Description&quot; src=&quot;/upload2024/202411/20241121145728367.jpg&quot; width=648 height=195&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Installation and usage conditions&lt;BR&gt;1. Altitude not exceeding 2000m (special instructions should be provided when ordering in high-altitude areas);&lt;BR&gt;2. The ambient air temperature ranges from -25 ¡æ to+40 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent accidental suction caused by vibration;&lt;BR&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand;&lt;BR&gt;5. Install with screws or 75mm U-shaped guide rails.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121145759246.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 584px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZY2-63C, 100C series DC contactors&quot; src=&quot;/upload2024/202411/20241121145759246.jpg&quot; width=680 height=584&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121145809742.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 192px&quot; border=0 hspace=0 alt=&quot;wiring diagram&quot; src=&quot;/upload2024/202411/20241121145809742.jpg&quot; width=650 height=192&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY22 series DC contactor </title>
           <link>http://www.91way.com/info_en/28031.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CZY22 series DC contactor is a newly developed product by Dongmu Company, with a rated current ranging from 40A to 80A and two normally open and two normally closed main contacts. CZY22 innovatively uses permanent magnet arc extinguishing technology, effectively solving the key problems of difficult critical breaking current and excessive wear of contacts in traditional contactors.&lt;BR&gt;&lt;BR&gt;1¡¢ Purpose:&lt;BR&gt;The CZY22 series DC contactor is suitable for frequent connection and disconnection of DC circuits over long distances. Its main control object is DC motors, and it is widely used in fire control equipment; It can replace dual power supply in the high-voltage switch control cabinet.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121145300844.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=0 hspace=0 alt=&quot;CZY22 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121145300844.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Installation and usage conditions&lt;BR&gt;1. Altitude not exceeding 2000m (special instructions should be provided when ordering in high-altitude areas);&lt;BR&gt;2. The ambient air temperature ranges from -25 ¡æ to+40 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent the mechanism from vibrating and accidentally engaging;&lt;BR&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand;&lt;BR&gt;5. Install with screws or 75mm U-shaped guide rails.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121145355639.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 649px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZY22 series DC contactor&quot; src=&quot;/upload2024/202411/20241121145355639.jpg&quot; width=680 height=649&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121145411807.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 505px&quot; border=0 hspace=0 alt=&quot;installation dimensions&quot; src=&quot;/upload2024/202411/20241121145411807.jpg&quot; width=680 height=505&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZC1(CZ28) series DC contactor </title>
           <link>http://www.91way.com/info_en/28030.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;CZC1 (CZ28) -25-630 series electromagnetic DC contactor is a vehicle electrical product mainly used in DC power systems, electrical drives, and vehicle DC circuits with rated DC voltages of 440V, 600V, and rated working currents of 25A~630A. It serves as a control component for starting, reverse braking or reversing, and inching of DC motors. This product complies with the GB 14048.4-2003/IEC60 947-4-7: 2000 standard.&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144703314.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 669px; HEIGHT: 322px&quot; border=0 hspace=0 alt=&quot;CZC1 (CZ28) series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121144703314.jpg&quot; width=669 height=322&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;3¡¢ Installation and usage conditions&lt;BR&gt;1. Altitude not exceeding 2000 meters;&lt;BR&gt;2. The ambient temperature is between+40 ¡æ and -25 ¡æ;&lt;BR&gt;3. Relative humidity of 50%~90% without condensation phenomenon;&lt;BR&gt;4. Enduring impact vibration: meets the requirements of 5.1.1. f in TB1333 &quot;Technical Conditions for Electrical Appliances&quot;;&lt;BR&gt;5. Installation conditions: The inclination angle between the installation surface of the contactor and the vertical surface shall not exceed 5 &#176;.&lt;BR&gt;4¡¢ Structural characteristics&lt;BR&gt;1. The product structure is simple, compact, lightweight, small in size, and serialized.&lt;BR&gt;2. Good arc initiation and extinguishing performance, using a bidirectional large arc initiation angle, and an arc extinguishing cover with a composite structure of unsaturated polyester flame retardant, arc resistant plastic, and ceramic double-layer labyrinth large arc extinguishing chamber. When the contact is disconnected, the arcing time is short and the service life is long.&lt;BR&gt;3. The attraction coil adopts high-strength polyester enameled wire, and the surface is pressed and formed with flame-retardant unsaturated polyester glass fiber molding material. Has good insulation performance and can achieve B-level insulation; Has strong mechanical properties, resistance to impact and vibration; Good moisture and heat resistance, meeting the requirements of three protections, and can be used in cars and ships.&lt;BR&gt;4. The magnetic plate adopts a thickened and widened iron plastic composite structure, which enhances the magnetic blowing ability, strengthens the insulation and flame retardant properties, and prevents the insulation sheet from being burned out by leakage arc, causing a short circuit in the magneto electric system.&lt;BR&gt;5. The auxiliary switch is used in high-power components of CZC1 (CZ28) -250-630 specifications, designed with double arc extinguishing chambers and a large opening distance of two pairs of one opening and one closing, to reliably open the arc.&lt;BR&gt;6. The right-handed magnetic blowing coil is designed in series with the main circuit, and the upper and lower busbars can be connected to the outside without polarity, which is convenient for users.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144728372.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 851px&quot; border=0 hspace=0 alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121144728372.jpg&quot; width=680 height=851&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144748748.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 848px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CZC1 (CZ28) series DC contactors&quot; src=&quot;/upload2024/202411/20241121144748748.jpg&quot; width=680 height=848&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144802395.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 856px&quot; border=0 hspace=0 alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121144802395.jpg&quot; width=680 height=856&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144815307.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 847px&quot; border=0 hspace=0 alt=&quot;Outline drawing of CZC1 (CZ28) series DC contactor&quot; src=&quot;/upload2024/202411/20241121144815307.jpg&quot; width=680 height=847&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144828839.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 665px&quot; border=0 hspace=0 alt=&quot;CZC1 (CZ28) series DC contactor wiring diagram&quot; src=&quot;/upload2024/202411/20241121144828839.jpg&quot; width=680 height=665&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ9 series DC contactor </title>
           <link>http://www.91way.com/info_en/28029.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:13</pubDate>
           <comments></comments>
           <description>1¡¢ Purpose:&lt;BR&gt;CZ9 DC contactor is suitable for communication power supplies below DC48V, uninterruptible power supplies, electric scooters, electric forklifts, excavators, automotive air conditioning and other electronic control systems. It controls the start and stop of DC motors, as well as the on/off of DC power supplies.&lt;BR&gt;&lt;BR&gt;2¡¢ Usage conditions&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Relative humidity: ¡Ü 85% at room temperature (+20 ¡æ);&lt;BR&gt;3. Fixed vibration frequency: 10~50Hz Acceleration: 10m/s &amp;sup2;;&lt;BR&gt;4. Impact acceleration: 30m/s &amp;sup2;;&lt;BR&gt;5. Altitude: ¡Ü 2000 meters.&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144224794.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 880px&quot; border=0 hspace=0 alt=&quot;CZ9 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121144224794.jpg&quot; width=680 height=880&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121144249832.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CZ9 series DC contactors&quot; src=&quot;/upload2024/202411/20241121144249832.jpg&quot; width=680 height=850&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ10 series single pole normally open DC contactor </title>
           <link>http://www.91way.com/info_en/28028.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:06:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CZ10 series single pole DC contactor is suitable for circuits with a rated DC current of 150A~600A and a working voltage of 48V. It is mainly used in programmable power supplies and uninterruptible power supply (UPS) systems.&lt;BR&gt;The CZ10 series contactor has a magnetic arc extinguishing function and can be equipped with one normally open and one normally closed auxiliary contact. The magnetic arc extinguishing function ensures that the product has a long electrical life. The characteristics of this product are compact structure, sturdy, 4 current levels, cadmium free double break point contact design, and wide range of coil control voltage applicability.&lt;BR&gt;The standards that the product complies with: IEC60947-1, EN1175-1, GB/T14048.1, GB14048.4&lt;BR&gt;&lt;BR&gt;1¡¢ Purpose:&lt;BR&gt;CZ10/150¡¢ The 250 series contactors are suitable for making and breaking in circuits with DC 150A and 250A, voltage 48V. CZ10/150¡¢ The 250 series contactor is a single pole normally open DC contactor with magnetic arc extinguishing function, suitable for breaking and converting in main or auxiliary circuits.&lt;BR&gt;CZ10/400¡¢ The 600 series contactors are suitable for making and breaking in circuits with DC 400A and 600A voltage of 48V. CZ10/400¡¢ The 600 series contactor is a single pole normally open DC contactor without magnetic arc extinguishing function, suitable for breaking and converting in main or auxiliary circuits.&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121142409887.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 450px&quot; border=0 hspace=0 alt=&quot;CZ10 series single pole normally open DC contactor model description&quot; src=&quot;/upload2024/202411/20241121142409887.jpg&quot; width=680 height=450&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121142431721.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 825px&quot; border=0 hspace=0 alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121142431721.jpg&quot; width=680 height=825&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121142446269.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 866px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CZ10 series single pole normally open DC contactor&quot; src=&quot;/upload2024/202411/20241121142446269.jpg&quot; width=680 height=866&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121142502997.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 848px&quot; border=0 hspace=0 alt=&quot;wiring diagram&quot; src=&quot;/upload2024/202411/20241121142502997.jpg&quot; width=680 height=848&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S137 series DC contactor </title>
           <link>http://www.91way.com/info_en/28027.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:57</pubDate>
           <comments></comments>
           <description>1¡¢ Purpose:&lt;BR&gt;The S137 DC contactor is mainly used in circuits with DC working voltage up to 220V, to remotely connect and disconnect DC circuits, and is particularly suitable for controlling railway locomotive heating, water heaters, lighting, etc. Not suitable for controlling frequent starting of DC motors and inductive coils.&lt;BR&gt;2¡¢ Usage conditions&lt;BR&gt;1. Altitude not exceeding 2000m;&lt;BR&gt;2. The ambient air temperature shall not be higher than+40 ¡æ and not lower than -25 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the vertical surface shall not exceed 10 &#176;;&lt;BR&gt;4. Installed in an environment that is resistant to rain, wind, and sand;&lt;BR&gt;5. There is no explosion hazard, no conductive dust, no damage to insulation, and no gas that can corrode metals in the surrounding air.&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241121142004708.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 648px; HEIGHT: 574px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of S137 series DC contactor&quot; src=&quot;/upload2024/202411/20241121142004708.jpg&quot; width=648 height=574&gt;&lt;/A&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JZY1-K Fast DC Relay </title>
           <link>http://www.91way.com/info_en/27934.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:48</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;JZY1-K fast DC relay, suitable for various protection and automatic control circuits in DC operation, as an outlet relay or to increase the number and capacity of protection and control circuit contacts.&lt;BR&gt;The normal DC operated relay has a contact breaking time of more than 30ms. The JZY1-K fast DC relay solves the requirement of fast DC operation breaking less than 20ms, and has been tested by the high-voltage switch factory to meet the requirements of high-voltage switch anti trip protection circuit.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202406/20240619150341102.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=0 hspace=0 alt=&quot;Model Description of JZY1-K Fast DC Relay&quot; src=&quot;/upload2024/202406/20240619150341102.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202406/20240619150411243.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 277px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JZY1-K fast DC relay&quot; src=&quot;/upload2024/202406/20240619150411243.jpg&quot; width=680 height=277&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202406/20240619150424323.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 525px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JZY1-K fast DC relay&quot; src=&quot;/upload2024/202406/20240619150424323.jpg&quot; width=680 height=525&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;4¡¢ Usage conditions&lt;BR&gt;1. Altitude not exceeding 2000m;&lt;BR&gt;2. The ambient air temperature ranges from+40 ¡æ to -25 ¡æ;&lt;BR&gt;3. The inclination angle between the installation surface and the vertical surface should not exceed+22.5 &#176; (as shown in the figure). When there is significant on-site vibration, it is recommended to install in the direction of vertical vibration to prevent vibration absorption;&lt;BR&gt;4. Installed in an environment that is resistant to rain, wind, and sand.&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S140,S190 series DC contactor </title>
           <link>http://www.91way.com/info_en/26460.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:40</pubDate>
           <comments></comments>
           <description>14040, S190 series DC contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Product Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;Drawing number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;arc extinguishing cover&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S309&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS5471&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;only&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;Paired with S307g&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S195SE-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6560&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S195SE-3-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6560&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;DF8B-LCU&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S140A-1-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S140A-2-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6601&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;intermediate relay&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S141A-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6721&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S150k series DC contactor </title>
           <link>http://www.91way.com/info_en/26459.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:32</pubDate>
           <comments></comments>
           <description>150k series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Product Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;Drawing number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Start the contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S157k-33-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6671&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Excitation contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S158k-33-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6682&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Wind pump contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S156k-33-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6661&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S155k-33-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6651&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S1001 type DC contactor </title>
           <link>http://www.91way.com/info_en/26458.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:24</pubDate>
           <comments></comments>
           <description>S1001 type DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Product Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;Drawing number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S1001/06-PC-44-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6106&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;DF8B AC Drive&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S1001/06-PC-33-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6105&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;DF8B AC Drive&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S1001/06-PB-44-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6116&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;DC contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S1001/06-PB-33-110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Start the contactor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=169&gt;
&lt;DIV align=center&gt;S157k-33-80V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;XS6671&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;DIV align=center&gt;Taiwan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC37 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/25364.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:05:16</pubDate>
           <comments></comments>
           <description>Purpose and conditions of use&lt;BR&gt;QCC37 DC electromagnetic contactor is suitable for use as a non-polar switch in industrial and mining electric locomotives, subways, light rail vehicles, railway traction locomotives, and passenger vehicles. It is used as a tap changer contactor and unit control contactor in the main and auxiliary circuits. These contactors are specially designed to withstand various extremely harsh working conditions encountered in electric traction locomotives. This type of contactor can also be used in heavy-duty equipment in mining and steel industries.&lt;BR&gt;&lt;BR&gt;Technical data of QCC37 series DC electromagnetic contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;project&lt;/TD&gt;
&lt;TD colSpan=2&gt;Technical data&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated voltage Un (V)&lt;/TD&gt;
&lt;TD&gt;one thousand and five hundred&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum operating voltage (V)&lt;/TD&gt;
&lt;TD&gt;one thousand and eight hundred&lt;/TD&gt;
&lt;TD&gt;one thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current Le (A)&lt;/TD&gt;
&lt;TD&gt;six hundred&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum breaking current (A)&lt;/TD&gt;
&lt;TD&gt;2400£¨T=15ms£©&lt;/TD&gt;
&lt;TD&gt;3200£¨T=15ms£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Closing time (ms)&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Ö100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Disconnecting time (ms)&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Ö50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2&gt;3&#215;10&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact pressure (N)&lt;/TD&gt;
&lt;TD colSpan=2&gt;55~75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact opening distance (mm)&lt;/TD&gt;
&lt;TD colSpan=2&gt;14.5¡«16.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control power supply (V)&lt;/TD&gt;
&lt;TD colSpan=2&gt;DC110&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control power (W)&lt;/TD&gt;
&lt;TD colSpan=2&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Weight (Kg)&lt;/TD&gt;
&lt;TD colSpan=2&gt;twelve&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201405/20140523202241807.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 867px&quot; border=0 hspace=0 alt=&quot;Structural schematic diagram of QCC37 series DC electromagnetic contactor&quot; src=&quot;/upload2014/201405/20140523202241807.jpg&quot; width=650 height=867&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC37 series DC electromagnetic contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28TG series railway locomotive DC contactor </title>
           <link>http://www.91way.com/info_en/24245.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CZ28TG series railway locomotive DC contactor&lt;BR&gt;&lt;BR&gt;The product code for humid and hot zones is represented by TH&lt;BR&gt;1. Number of normally closed main contacts&lt;BR&gt;2. Number of normally open main contacts&lt;BR&gt;3. Derivative code (G-plateau type)&lt;BR&gt;4. Derivative code (T-railway specific)&lt;BR&gt;5. Rated working current value&lt;BR&gt;6. DC contactor and design code&lt;BR&gt;&lt;BR&gt;Product Structure Features:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212185235398.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 659px; HEIGHT: 616px&quot; border=0 hspace=0 alt=&quot;Technical parameters and structural diagram of CZ28TG series railway locomotive DC contactor&quot; src=&quot;/upload2013/201312/20131212185235398.jpg&quot; width=659 height=616&gt;&lt;/A&gt;&lt;BR&gt;CZ28TG series railway locomotive DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CCZ35 series DC contactor </title>
           <link>http://www.91way.com/info_en/24228.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:51</pubDate>
           <comments></comments>
           <description>CCZ35-200/10 DC contactor is suitable for remote connection, disconnection or reverse connection of brake oil pump DC motor in electronic control systems with rated working voltage of 12-24V and rated working current of 200A. This product is designed for short-term operation, with natural arc extinguishing and zero arcing distance. In the process of automatic control, the contactor control circuit controls the rated control voltage of the contactor coil through the relay in the control current, so as to generate or eliminate electromagnetic force in the magnetic system of the contactor. The armature drives the main contact to connect or disconnect the circuit under the action of electromagnetic force.&lt;BR&gt;&lt;BR&gt;The CCZ35 series DC contactor has the following characteristics:&lt;BR&gt;1. Natural arc extinguishing, zero arc spraying distance. The design of the reaction force spring and the contact spring is in a straight line, so that the reaction force and the main force do not produce a force component, which improves the breaking speed, greatly shortens the residence time of the arc on the contact, and avoids the phenomenon of contact burnout.&lt;BR&gt;2. The main circuit inlet and outlet terminals are designed to be integrated with the static contacts, solving the problem of main circuit heating caused by fastener connection or welding.&lt;BR&gt;3. The integrated design of the input and output wire connectors of the electromagnetic coil and the skeleton eliminates the error of manual welding.&lt;BR&gt;4. Small size, light weight, and easy disassembly.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-2400(1600)Q/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/24226.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:43</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212101036796.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CZ28-2400 (1600) Q/10 DC contactor&quot; src=&quot;/upload2013/201312/20131212101036796.jpg&quot; width=640 height=480&gt;&lt;/A&gt;&lt;BR&gt;CZ28-2400 (1600) Q/10 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-1250Q/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24225.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:35</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212095850612.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CZ28-1250Q/10 DC contactor&quot; src=&quot;/upload2013/201312/20131212095850612.jpg&quot; width=640 height=480&gt;&lt;/A&gt;&lt;BR&gt;CZ28-1250Q/10 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-200X DC contactor (energy-saving type) </title>
           <link>http://www.91way.com/info_en/24223.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CZ28-200X DC contactor (energy-saving type)&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-350X/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24222.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:18</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CZ28-350X/10 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-1800/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24221.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CZ28-1800£¯10&lt;BR&gt;1. CZ DC contactor code&lt;BR&gt;2. 28- Design code&lt;BR&gt;3. 1800 rated working current&lt;BR&gt;4. 10. Normally open unipolar type&lt;BR&gt;&lt;BR&gt;Structural characteristics of CZ28-1800/10 DC contactor:&lt;BR&gt;There are three types of combination structures for each set of auxiliary contacts: one normally open, two normally open/two normally closed.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212094618683.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=0 hspace=0 alt=&quot;CZ28-1800/10 DC contactor appearance and installation dimensions&quot; src=&quot;/upload2013/201312/20131212094618683.jpg&quot; width=640 height=480&gt;&lt;/A&gt;&lt;BR&gt;CZ28-1800/10 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28T series railway locomotive DC contactor </title>
           <link>http://www.91way.com/info_en/24219.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:04:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212093837746.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 596px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CZ28T series railway locomotive DC contactor&quot; src=&quot;/upload2013/201312/20131212093837746.jpg&quot; width=680 height=596&gt;&lt;/A&gt;&lt;BR&gt;CZ28T series railway locomotive DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28G series high-voltage DC contactor </title>
           <link>http://www.91way.com/info_en/24218.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:54</pubDate>
           <comments></comments>
           <description>&lt;P&gt;
&lt;P align=center&gt;Basic Parameters Table of CZ28G Series High Voltage DC Contactor Main Circuit&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=107&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=80&gt;
&lt;P&gt;Rated insulation voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;Agreed heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=204 colSpan=3&gt;
&lt;P&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P&gt;Attraction coil power (W)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=47&gt;
&lt;P&gt;DC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;DC-3&lt;/P&gt;
&lt;P&gt;DC-5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;Uninterrupted work system&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-40G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=13 width=80&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=13 width=72&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=84&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;thirty-two&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-63G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-100G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;GZ28-160G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=84&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-200G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-250G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-315G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=84&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-400G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-500G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-630G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;sixty-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-800G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-1000G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;P&gt;CZ28-1250G/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: When using CZ28G series contactors for DC-3 and DC-5 load categories with high operating frequency and slight movement, appropriate capacity reduction should be considered. They can be used at 80% of the agreed heating current value listed in the table.&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28Q series light load DC contactor </title>
           <link>http://www.91way.com/info_en/24217.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:46</pubDate>
           <comments></comments>
           <description>CZ28Q series light load DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=115&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;Rated insulation voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;Agreed heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180 colSpan=2&gt;
&lt;P&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=108&gt;
&lt;P&gt;Attraction coil power (W)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;
&lt;P&gt;DC-20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;Uninterrupted work system&lt;SUP&gt;(1)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-800Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=72&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=72&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=108&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;sixty-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-1000Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-1250Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-1450Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand four hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;one thousand four hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;one thousand four hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=108&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;110/33&lt;SUP&gt;(1)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-1600Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-2000Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P&gt;CZ28-2400Q/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two thousand and four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;two thousand and four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P&gt;two thousand and four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: (1) The power of the attraction coil in the table, the numerator value represents the starting power, and the denominator value represents the holding power.&lt;BR&gt;(2) The CZ28Q series light load DC contactor should be controlled to reduce capacity by 80% when the ambient temperature is high or the ventilation conditions are poor under uninterrupted operation.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28 series standard DC contactor </title>
           <link>http://www.91way.com/info_en/24216.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:37</pubDate>
           <comments></comments>
           <description>CZ28 series standard DC contactor&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212092654661.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 269px&quot; border=0 hspace=0 alt=&quot;CZ28 Series Standard DC Contactor Model Description&quot; src=&quot;/upload2013/201312/20131212092654661.jpg&quot; width=680 height=269&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=91&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=48&gt;
&lt;P&gt;Rated insulation voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=48&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=60&gt;
&lt;P&gt;Agreed heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=4&gt;
&lt;P align=center&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=60&gt;
&lt;P&gt;Attraction coil power (W)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=220 colSpan=3&gt;
&lt;P align=center&gt;Intermittent cycle work system&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=92&gt;
&lt;P&gt;Uninterrupted work system&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P&gt;DC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;DC-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P&gt;DC-5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-25/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;four hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;four hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P align=center&gt;25(1)&lt;/P&gt;
&lt;P&gt;£¨2.5,5,10,20£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;25(1)&lt;/P&gt;
&lt;P&gt;£¨2.5,5,10,20£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;25(1)&lt;/P&gt;
&lt;P&gt;£¨2.5,5,10,20£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P align=center&gt;25(1)&lt;/P&gt;
&lt;P&gt;£¨2.5,5,10,20£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P align=center&gt;25(1)&lt;/P&gt;
&lt;P&gt;£¨2.5,5,10,20£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;eighteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/02&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-40/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=32 width=48&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=32 width=48&gt;
&lt;P&gt;seven hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P align=center&gt;40(1)&lt;/P&gt;
&lt;P&gt;£¨5,10,20,32£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;40(1)&lt;/P&gt;
&lt;P&gt;£¨5,10,20,32£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;40(1)&lt;/P&gt;
&lt;P&gt;£¨5,10,20,32£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P align=center&gt;40(1)&lt;/P&gt;
&lt;P&gt;£¨5,10,20,32£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P align=center&gt;40(1)&lt;/P&gt;
&lt;P&gt;£¨5,10,20,32£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-40/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-40/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-40/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-63/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P align=center&gt;63(1)&lt;/P&gt;
&lt;P&gt;£¨16,40£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;63(1)&lt;/P&gt;
&lt;P&gt;£¨16,40£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P align=center&gt;63(1)&lt;/P&gt;
&lt;P&gt;£¨16,40£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P align=center&gt;63(1)&lt;/P&gt;
&lt;P&gt;£¨16,40£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P align=center&gt;63(1)&lt;/P&gt;
&lt;P&gt;£¨16,40£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-63/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-63/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-63/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-100/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-100/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-100/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-100/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-160D/10&lt;SUP&gt;(2)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=76&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=92&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-160D/10&lt;SUP&gt;(2)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-160/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-160/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-160/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-160/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-200/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-200/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-200/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-200/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-250/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-250/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-250/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-250/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-315/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=72&gt;
&lt;P&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=76&gt;
&lt;P&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=92&gt;
&lt;P&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;sixty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-25/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;CZ28-315D/10&lt;SUP&gt;(2)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=76&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=92&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;P align=right&gt;-315D/20&lt;SUP&gt;(2)&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=103&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=48&gt;
&lt;P&gt;Rated insulation voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=48&gt;
&lt;P&gt;Rated working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=60&gt;
&lt;P&gt;Agreed heating current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=4&gt;
&lt;P align=center&gt;Rated working current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=61&gt;
&lt;P&gt;Attraction coil power (W)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216 colSpan=3&gt;
&lt;P align=center&gt;Intermittent cycle work system&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P&gt;Uninterrupted work system&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;
&lt;P&gt;DC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;DC-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;DC-5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-400/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=16 width=48&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=16 width=48&gt;
&lt;P align=center&gt;seven hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-400/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-400/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;fifty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-400/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-500/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-500/20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-500/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-500/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-630/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-630/20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-630/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-630/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-800/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-800/20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-800/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-800/02&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-1000/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=14 width=48&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=14 width=48&gt;
&lt;P&gt;seven hundred and fifty&lt;/P&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;seventy-one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1000/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;71&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1000/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1000/02&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;97&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-1600/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1600/20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1600/01&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;-1600/02&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;97&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-2500/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;2000/1600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;2000/1600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-2500/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;2500/2000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;2500/2000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;71&#215;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-3150/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;3150/2500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;3150/2500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-4000/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;4000/3150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;4000/3150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-5000/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;5000/4000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;5000/4000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;five thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;6&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=right&gt;CZ28-6000/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;6000/5000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;6000/5000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;P&gt;82&#215;6&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: (1) The numbers 2.5, 5, 10, 16, 20, 32, 40 in parentheses in the table represent the rated current of the arc blowing coil, indicating that the contactor can also be used in situations where the rated working current specified is lower.&lt;BR&gt;(2) Models with &quot;D&quot; indicate that the product is specifically designed for subway use.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-44F type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/20225.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:29</pubDate>
           <comments></comments>
           <description>The JQ-44F high-power DC contactor has the characteristics of high load, stable operation, and high reliability, and can be widely used in various devices such as high-power power switching&lt;BR&gt;&lt;BR&gt;Product specification: 24VDC&lt;BR&gt;Load: 400A, 450VDC&lt;BR&gt;Product size: 85mm &#215; 85mm &#215; 120mm&lt;BR&gt;Product weight: 250g&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-100A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18797.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403175212988.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 807px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC15-100A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403175212988.jpg&quot; width=680 height=807&gt;&lt;/A&gt;&lt;BR&gt;QCC15-100A/10 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-200A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18796.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403175012890.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 806px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC15-200A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403175012890.jpg&quot; width=680 height=806&gt;&lt;/A&gt;&lt;BR&gt;QCC15-200A/10 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-400A/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18795.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:03:04</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403174233254.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 854px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC25C-400A/11 DC Contactor&quot; src=&quot;/upload2012/201204/20120403174233254.jpg&quot; width=680 height=854&gt;&lt;/A&gt;&lt;BR&gt;QCC25C-400A/11 type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-100A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18794.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:56</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403174007497.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 782px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC25C DC Contactor&quot; src=&quot;/upload2012/201204/20120403174007497.jpg&quot; width=680 height=782&gt;&lt;/A&gt;&lt;BR&gt;QCC25C-100A/22 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-400A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18793.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:48</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403173807405.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 818px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC25C-400A/22 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173807405.jpg&quot; width=680 height=818&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC25C-400A/22 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-400/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18792.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:40</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403173515946.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 813px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC26C-400/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173515946.jpg&quot; width=680 height=813&gt;&lt;/A&gt;&lt;BR&gt;QCC26C-400/10 type DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-100A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18791.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:32</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403173309564.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 806px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC26C-100A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173309564.jpg&quot; width=680 height=806&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC26C-100A/10 type DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-400S type DC contactor </title>
           <link>http://www.91way.com/info_en/18790.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:24</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403165919187.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 796px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TXZJB-400S DC Contactor&quot; src=&quot;/upload2012/201204/20120403165919187.jpg&quot; width=680 height=796&gt;&lt;/A&gt;&lt;BR&gt;TXZJB-400S DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-600S type DC contactor </title>
           <link>http://www.91way.com/info_en/18789.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:16</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403165727529.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 803px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TXZJB-600S DC Contactor&quot; src=&quot;/upload2012/201204/20120403165727529.jpg&quot; width=680 height=803&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TXZJB-600S DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-100D type DC contactor </title>
           <link>http://www.91way.com/info_en/18788.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:02:08</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403165521814.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 817px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TXZJB-100D DC Contactor&quot; src=&quot;/upload2012/201204/20120403165521814.jpg&quot; width=680 height=817&gt;&lt;/A&gt;&lt;BR&gt;TXZJB-100D DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-200S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18787.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:59</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403163939239.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 813px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TXZJB-200S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403163939239.jpg&quot; width=680 height=813&gt;&lt;/A&gt;&lt;BR&gt;TXZJB-200S/02 DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-400S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18786.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:51</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403163703708.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/upload2012/201204/20120403163703708.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;TXZJB-400S/02 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-600S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18785.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:43</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403163502390.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 792px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TXZJB-600S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403163502390.jpg&quot; width=680 height=792&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TXZJB-600S/02 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-600S type DC contactor </title>
           <link>http://www.91way.com/info_en/18784.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:35</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403162813212.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 852px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of MZJ-600S DC Contactor&quot; src=&quot;/upload2012/201204/20120403162813212.jpg&quot; width=588 height=852&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;MZJ-600S DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-100S type DC contactor </title>
           <link>http://www.91way.com/info_en/18783.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:27</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403162635581.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 880px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of MZJ-100S DC Contactor&quot; src=&quot;/upload2012/201204/20120403162635581.jpg&quot; width=580 height=880&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;MZJ-100S DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-100S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18782.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:18</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403162400287.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 576px; HEIGHT: 897px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of MZJ-100S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403162400287.jpg&quot; width=576 height=897&gt;&lt;/A&gt;&lt;BR&gt;MZJ-100S/02 DC contactor&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-200S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18781.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:10</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403161332332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 570px; HEIGHT: 859px&quot; border=0 hspace=0 alt=&quot;Technical parameters and external dimensions of MZJ-200S/02 DC contactor&quot; src=&quot;/upload2012/201204/20120403161332332.jpg&quot; width=570 height=859&gt;&lt;/A&gt;&lt;BR&gt;MZJ-200S/02 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-400S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18780.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:01:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403155733117.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 572px; HEIGHT: 884px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of MZJ-400S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155733117.jpg&quot; width=572 height=884&gt;&lt;/A&gt;&lt;BR&gt;MZJ-400S/02 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-600S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18779.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403155507532.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 566px; HEIGHT: 875px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of MZJ-600S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155507532.jpg&quot; width=566 height=875&gt;&lt;/A&gt;&lt;BR&gt;MZJ-600S/02 DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25B-150A/200A/300A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18778.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:46</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403155033545.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 673px; HEIGHT: 868px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC25B-150A/200A/300A/22 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155033545.jpg&quot; width=673 height=868&gt;&lt;/A&gt;&lt;BR&gt;QCC25B-150A/200A/300A/22 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26B-150A/200A/300A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18777.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:38</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403154817743.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 795px&quot; border=0 hspace=0 alt=&quot;QCC26B-150A/200A/300A/10 type DC contactor external dimensions and technical parameters&quot; src=&quot;/upload2012/201204/20120403154817743.jpg&quot; width=680 height=795&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC26B-150A/200A/300A/10 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-25/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18776.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403154446191.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 788px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC15-25/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403154446191.jpg&quot; width=680 height=788&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC15-25/10 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-40A/10B type DC contactor </title>
           <link>http://www.91way.com/info_en/18775.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403154227230.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 790px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC15-40A/10B DC Contactor&quot; src=&quot;/upload2012/201204/20120403154227230.jpg&quot; width=680 height=790&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC15-40A/10B DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC28-160A/400A/20B type DC contactor </title>
           <link>http://www.91way.com/info_en/18774.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403153847839.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 679px; HEIGHT: 865px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC28-160A/400A/20A DC Contactor&quot; src=&quot;/upload2012/201204/20120403153847839.jpg&quot; width=679 height=865&gt;&lt;/A&gt;&lt;BR&gt;QCC28-160A/400A/20A DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC14-100A/150A/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18773.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 11:00:05</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403153411595.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 684px; HEIGHT: 897px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC14-100A/150A/11 DC Contactor&quot; src=&quot;/upload2012/201204/20120403153411595.jpg&quot; width=684 height=897&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC14-100A/150A/11 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC29-160A/400A/10B type DC contactor </title>
           <link>http://www.91way.com/info_en/18772.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:57</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403152317309.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 784px&quot; border=0 hspace=0 alt=&quot;Technical parameters of QCC29-160A/400A/10B DC contactor&quot; src=&quot;/upload2012/201204/20120403152317309.jpg&quot; width=680 height=784&gt;&lt;/A&gt;&lt;BR&gt;QCC29-160A/400A/10B DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC34-250A/10B/20B type DC contactor </title>
           <link>http://www.91way.com/info_en/18771.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:48</pubDate>
           <comments></comments>
           <description>QCC34-250A/10B/20A DC Contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ17-150A/10/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18770.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:40</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403151318720.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 782px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZ17-150A/10/11 DC contactor&quot; src=&quot;/upload2012/201204/20120403151318720.jpg&quot; width=680 height=782&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CZ17-150A/10/11 type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]High voltage strong magnetic blow DC contactor </title>
           <link>http://www.91way.com/info_en/18769.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:32</pubDate>
           <comments></comments>
           <description>Product Application&lt;BR&gt;The GZJ-250A/10B high-voltage strong magnetic blow DC contactor series products are currently the only DC electrical products produced by Lutong Company in the domestic DC electrical industry with international advanced level characteristics such as high voltage, high current, small size, light weight, and strong arc breaking ability. It is mainly used for high-voltage and high current power switching and uninterruptible power supply systems in various fields such as traction locomotives, railway locomotives, mining machinery, petrochemicals, metallurgical ships, telecommunications, computers, etc. This product complies with standards such as IEC77 &quot;Rules for Electric Traction Equipment&quot; and TB1333-1996 &quot;Basic Technical Conditions for Locomotive Electrical Appliances&quot;.&lt;BR&gt;&lt;BR&gt;Product Features&lt;BR&gt;Maximum breaking capacity of the main contact: 4 times the rated load current (5ms duration) for one breaking, and the rated load current value is determined based on the voltage value in the performance parameter table.&lt;BR&gt;Voltage fluctuation range: 80%~120% (communication contactors) 70%~110% (vehicle contactors)&lt;BR&gt;Main contact voltage drop: not more than 60mV under 100A load (for communication), not more than 80mV (for vehicle)&lt;BR&gt;Electrical strength: AC 50HZ/2KV&lt;BR&gt;Coil working range: continuous and intermittent working system (user selectable)&lt;BR&gt;Environmental temperature: -25~45 ¡æ&lt;BR&gt;Installation direction: The inclination of the relative vertical installation position should not exceed 10 &amp;ordm;&lt;BR&gt;It should be installed in a waterproof and dustproof box.&lt;BR&gt;Note: Products with special parameters will be negotiated separately by the customer. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Performance parameters of GZJ-250A/10B high-voltage strong magnetic blow DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=202&gt;
&lt;DIV align=center&gt;Parameter Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;Product model&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;GZJ-250A/10B&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Number and type of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;1NO&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Main contact current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;250A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Contact rated voltage V (DC)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;630V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Rated voltage of coil V (DC)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=61&gt;
&lt;DIV align=center&gt;two hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Rated insulation voltage V (AC)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;1600V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Rated impulse voltage V (AC)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;6000V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=202&gt;
&lt;DIV align=center&gt;Number and type of auxiliary contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=362 colSpan=6&gt;
&lt;DIV align=center&gt;2&#215;NO&amp;nbsp;2&#215;NC&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120403150941999.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 265px; HEIGHT: 290px&quot; border=0 hspace=0 alt=&quot;GZJ-250A/10B high-voltage strong magnetic blow DC contactor external dimensions&quot; src=&quot;/upload2012/201204/20120403150941999.jpg&quot; width=265 height=290&gt;&lt;/A&gt;&lt;BR&gt;Overall dimensions&lt;BR&gt;&lt;BR&gt;GZJ-250A/10B high-voltage strong magnetic blow DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CCZ38 series DC contactor </title>
           <link>http://www.91way.com/info_en/13517.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:24</pubDate>
           <comments></comments>
           <description>CCZ38 series DC contactor&lt;BR&gt;Features:&lt;BR&gt;Features such as compact structure, small size, easy maintenance, and long service life.&lt;BR&gt;&lt;BR&gt;Specifications:&lt;BR&gt;Adopting a combination of maze and narrow gap arc extinguishing system, the arc spraying distance is small, the contacts are not easily burned out, and the use is reliable;&lt;BR&gt;&lt;BR&gt;Purpose:&lt;BR&gt;The CCZ38 series DC contactor is mainly used for the on-off of DC motors in mechanical equipment such as petroleum, railway, and light rail trams.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-200A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/7682.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:15</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120403170212844.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 828px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of QCC26C-200A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403170212844.jpg&quot; width=680 height=828&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;QCC26C-200A/10 type DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ200P series DC contactor </title>
           <link>http://www.91way.com/info_en/6982.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:59:05</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ2 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=60&gt;thirty-six&lt;/TD&gt;
&lt;TD width=48&gt;forty&lt;/TD&gt;
&lt;TD width=48&gt;forty-eight&lt;/TD&gt;
&lt;TD width=48&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;two point five&lt;/TD&gt;
&lt;TD width=48&gt;one point five&lt;/TD&gt;
&lt;TD width=48&gt;zero point six&lt;/TD&gt;
&lt;TD width=60&gt;zero point nine&lt;/TD&gt;
&lt;TD width=48&gt;zero point eight five&lt;/TD&gt;
&lt;TD width=48&gt;zero point eight two&lt;/TD&gt;
&lt;TD width=48&gt;zero point five&lt;/TD&gt;
&lt;TD width=48&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ2XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091019205756517.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ200P series DC contactor&quot; src=&quot;/upload2009/200910/20091019205756517.jpg&quot; width=554 height=295&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920589219.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;ZJQ200P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920589219.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019205816876.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ200P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019205816876.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ100P series DC contactor </title>
           <link>http://www.91way.com/info_en/6981.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:57</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZJ ZJQ1 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=60&gt;thirty-six&lt;/TD&gt;
&lt;TD width=48&gt;forty&lt;/TD&gt;
&lt;TD width=48&gt;forty-eight&lt;/TD&gt;
&lt;TD width=48&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;two point five&lt;/TD&gt;
&lt;TD width=48&gt;one point five&lt;/TD&gt;
&lt;TD width=48&gt;zero point six&lt;/TD&gt;
&lt;TD width=60&gt;zero point nine&lt;/TD&gt;
&lt;TD width=48&gt;zero point eight five&lt;/TD&gt;
&lt;TD width=48&gt;zero point eight two&lt;/TD&gt;
&lt;TD width=48&gt;zero point five&lt;/TD&gt;
&lt;TD width=48&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ1XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091019203524375.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 292px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ100P series DC contactor&quot; src=&quot;/upload2009/200910/20091019203524375.jpg&quot; width=600 height=292&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019203555118.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJQ100P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019203555118.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Product model meaning&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/2009101920369811.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ100P series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101920369811.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB600A type DC contactor </title>
           <link>http://www.91way.com/info_en/6980.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:49</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZJB600A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202825458.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJB600A DC contactor&quot; src=&quot;/upload2009/200910/20091019202825458.jpg&quot; width=680 height=220&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202815237.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=0 hspace=0 alt=&quot;ZJB600A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019202815237.jpg&quot; width=287 height=126&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920289315.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJB600A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920289315.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB400S type DC contactor </title>
           <link>http://www.91way.com/info_en/6979.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:41</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJB400S series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 400A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;ZJB400S coil holding current (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;twenty-four&lt;/TD&gt;
&lt;TD width=216&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;zero point three&lt;/TD&gt;
&lt;TD width=216&gt;zero point one two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202458715.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 339px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJB400S DC contactor&quot; src=&quot;/upload2009/200910/20091019202458715.jpg&quot; width=553 height=339&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920258882.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJB400S DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920258882.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202517197.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJB400S DC Contactor&quot; src=&quot;/upload2009/200910/20091019202517197.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB200S type DC contactor </title>
           <link>http://www.91way.com/info_en/6978.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:33</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJB200S series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;ZJB200S coil holding current (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;twenty-four&lt;/TD&gt;
&lt;TD width=216&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;zero point three six&lt;/TD&gt;
&lt;TD width=216&gt;zero point two five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202126244.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 341px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJB200S DC contactor&quot; src=&quot;/upload2009/200910/20091019202126244.jpg&quot; width=553 height=341&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202133618.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJB200S DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019202133618.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019202145122.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJB200S DC Contactor&quot; src=&quot;/upload2009/200910/20091019202145122.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ600A type DC contactor </title>
           <link>http://www.91way.com/info_en/6977.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:24</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ600A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 600A, maximum allowable current 4le, 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;six&lt;/TD&gt;
&lt;TD width=48&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=45&gt;thirty-six&lt;/TD&gt;
&lt;TD width=39&gt;forty&lt;/TD&gt;
&lt;TD width=48&gt;forty-eight&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;zero point nine five&lt;/TD&gt;
&lt;TD width=48&gt;zero point six&lt;/TD&gt;
&lt;TD width=48&gt;zero point three&lt;/TD&gt;
&lt;TD width=48&gt;zero point two five&lt;/TD&gt;
&lt;TD width=45&gt;zero point two&lt;/TD&gt;
&lt;TD width=39&gt;zero point one eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point two one&lt;/TD&gt;
&lt;TD width=36&gt;zero point one&lt;/TD&gt;
&lt;TD width=48&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;ZJ600A type DC contactor external installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201715679.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 431px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJ600A DC contactor&quot; src=&quot;/upload2009/200910/20091019201715679.jpg&quot; width=431 height=291&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201730731.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJ600A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019201730731.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201739102.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJ600A DC Contactor&quot; src=&quot;/upload2009/200910/20091019201739102.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ100A type DC contactor </title>
           <link>http://www.91way.com/info_en/6976.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:15</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ100A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A, maximum allowable current 4le, 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;six&lt;/TD&gt;
&lt;TD width=48&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=45&gt;thirty-six&lt;/TD&gt;
&lt;TD width=39&gt;forty&lt;/TD&gt;
&lt;TD width=48&gt;forty-eight&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;zero point nine five&lt;/TD&gt;
&lt;TD width=48&gt;zero point six&lt;/TD&gt;
&lt;TD width=48&gt;zero point three&lt;/TD&gt;
&lt;TD width=48&gt;zero point two five&lt;/TD&gt;
&lt;TD width=45&gt;zero point two&lt;/TD&gt;
&lt;TD width=39&gt;zero point one eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point two one&lt;/TD&gt;
&lt;TD width=36&gt;zero point one&lt;/TD&gt;
&lt;TD width=48&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Installation diagram of ZJ100A DC contactor appearance&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201412557.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 442px; HEIGHT: 306px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJ100A DC contactor&quot; src=&quot;/upload2009/200910/20091019201412557.jpg&quot; width=442 height=306&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201420879.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJ100A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019201420879.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019201431515.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJ100A DC Contactor&quot; src=&quot;/upload2009/200910/20091019201431515.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJ100A type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6975.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:58:07</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJB200A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;ZJB200A coil holding current (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;twenty-four&lt;/TD&gt;
&lt;TD width=216&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;zero point three six&lt;/TD&gt;
&lt;TD width=216&gt;zero point two five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920936804.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 341px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJB200A DC contactor&quot; src=&quot;/upload2009/200910/2009101920936804.jpg&quot; width=553 height=341&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920949144.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=0 hspace=0 alt=&quot;ZJB200A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920949144.jpg&quot; width=287 height=126&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920959810.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJB200A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920959810.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6974.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:59</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJB400A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 400A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;ZJB400A coil holding current (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;twenty-four&lt;/TD&gt;
&lt;TD width=216&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;zero point three&lt;/TD&gt;
&lt;TD width=216&gt;zero point one two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Usage conditions of ZJB400A DC contactor&lt;BR&gt;&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;External Installation Drawing of ZJB400A DC Contactor&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920632735.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 339px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJB400A DC contactor&quot; src=&quot;/upload2009/200910/2009101920632735.jpg&quot; width=553 height=339&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920638764.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=0 hspace=0 alt=&quot;ZJB400A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920638764.jpg&quot; width=287 height=126&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101920646920.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJB400A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920646920.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6973.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:51</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ400A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 400A, maximum allowable current 4le, 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;six&lt;/TD&gt;
&lt;TD width=48&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=45&gt;thirty-six&lt;/TD&gt;
&lt;TD width=39&gt;forty&lt;/TD&gt;
&lt;TD width=48&gt;forty-eight&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;zero point nine five&lt;/TD&gt;
&lt;TD width=48&gt;zero point six&lt;/TD&gt;
&lt;TD width=48&gt;zero point three&lt;/TD&gt;
&lt;TD width=48&gt;zero point two five&lt;/TD&gt;
&lt;TD width=45&gt;zero point two&lt;/TD&gt;
&lt;TD width=39&gt;zero point one eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point two one&lt;/TD&gt;
&lt;TD width=36&gt;zero point one&lt;/TD&gt;
&lt;TD width=48&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101920248101.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 443px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJ400A DC contactor&quot; src=&quot;/upload2009/200910/2009101920248101.jpg&quot; width=443 height=295&gt;&lt;/A&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101920255814.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJ400A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920255814.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/6972.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:42</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW00A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;twelve&lt;/TD&gt;
&lt;TD width=48&gt;twenty-four&lt;/TD&gt;
&lt;TD width=48&gt;thirty&lt;/TD&gt;
&lt;TD width=48&gt;thirty-six&lt;/TD&gt;
&lt;TD width=45&gt;forty&lt;/TD&gt;
&lt;TD width=39&gt;forty-eight&lt;/TD&gt;
&lt;TD width=48&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD width=48&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;zero point nine eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point five eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point four five&lt;/TD&gt;
&lt;TD width=48&gt;zero point three five&lt;/TD&gt;
&lt;TD width=45&gt;zero point three two&lt;/TD&gt;
&lt;TD width=39&gt;zero point two eight&lt;/TD&gt;
&lt;TD width=48&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD width=48&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019195321249.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW100A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019195321249.jpg&quot; width=553 height=250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019195332839.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 142px&quot; border=0 hspace=0 alt=&quot;ZJW100A-2T DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019195332839.jpg&quot; width=554 height=142&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019195341125.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 412px; HEIGHT: 148px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW100A-2T DC Contactor&quot; src=&quot;http://www.91way.com/upload2009/200910/20091019195341125.jpg&quot; width=412 height=148&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWTP50DE type electric winch dedicated DC contactor </title>
           <link>http://www.91way.com/info_en/6970.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:34</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWTP50DE series short-term working system products are suitable for matching with electric winches in automobiles, with the characteristics of high load resistance and waterproofing, and reliable quality. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated current 50A, maximum allowable passing current 4le, 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated current (¦Ó=1ms), 1le, 20000 cycles, 4x current (DC-5): 1le, 200 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;The coil consumes a large power of 17 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD&gt;Coil voltage 12V&lt;/TD&gt;
&lt;TD&gt;Coil voltage 24V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;1£®6A&lt;/TD&gt;
&lt;TD&gt;0.8A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Appearance and installation diagram of ZJWTP50DE electric winch dedicated DC contactor&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194516320.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 290px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWTP50DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194516320.jpg&quot; width=680 height=290&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194524557.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 147px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWTP50DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194524557.jpg&quot; width=380 height=147&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194531257.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 363px; HEIGHT: 152px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWTP50DE Special DC Contactor for Electric Winch&quot; src=&quot;/upload2009/200910/20091019194531257.jpg&quot; width=363 height=152&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]Special DC contactor for electric winch </title>
           <link>http://www.91way.com/info_en/6969.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:26</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWTP100DE series short-term working system products are suitable for matching with electric winches in automobiles, with the characteristics of high load resistance and waterproofing, and reliable quality.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated current of main contact (A)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated current 100A, maximum allowable passing current 4le, 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Rated current (¦Ó=1ms), 1le, 20000 cycles, 4x current (DC-5): 1le, 200 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;The coil consumes a large power of 17 watts, and the maximum current of the coil is (A)&lt;/TD&gt;
&lt;TD width=&quot;41%&quot;&gt;Coil voltage 12V&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Coil voltage 24V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;2.2A&lt;/TD&gt;
&lt;TD&gt;1.1A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194122151.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWTP100DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194122151.jpg&quot; width=680 height=250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194139243.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 147px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWTP100DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194139243.jpg&quot; width=380 height=147&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019194150974.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 361px; HEIGHT: 152px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWTP100DE DC Contactor for Electric Winch&quot; src=&quot;/upload2009/200910/20091019194150974.jpg&quot; width=361 height=152&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW200A-03 type DC contactor </title>
           <link>http://www.91way.com/info_en/6968.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:18</pubDate>
           <comments></comments>
           <description>The ZJW200A-03 DC contactor has three normally open, three normally closed, and magnetic holding structures, and is used in various mobile, telecommunications, and China Unicom communication stations; Other types of power equipment.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;&lt;TD2 colspan=&quot;10&quot; width=&quot;631&quot;&gt;&lt;BR&gt;Technical Specifications&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2 rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/TD&gt;&lt;BR&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD width=45&gt;forty&lt;/TD&gt;
&lt;TD width=39&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD width=45&gt;zero point three two&lt;/TD&gt;
&lt;TD width=39&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=631 colSpan=10&gt;
&lt;P&gt;Note: 1. The coil can be used for AC 110V-220V and DC 12V-220V&lt;BR&gt;2. Contact can be used for AC 220V to 380V DC 6V to 80V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ500P series DC contactor </title>
           <link>http://www.91way.com/info_en/6967.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:09</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJQ500 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters&lt;BR&gt;&lt;SPAN class=title_3&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;Rated current of main contact&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;Resistive load ¦Ó=1ms, 300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;dielectric strength&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;50Hz 1000V AC 1min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;Action Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;Action characteristics&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;1 million times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=274&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=274&gt;
&lt;DIV&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=706 colSpan=8&gt;
&lt;DIV&gt;Rated voltage of coil and contact (V)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=310&gt;
&lt;DIV&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;DIV&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=310&gt;
&lt;DIV&gt;two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;zero point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;DIV&gt;zero point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV&gt;zero point eight five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV&gt;zero point eight two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;DIV&gt;zero point four five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/SPAN&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019193414271.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 294px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ500P series DC contactor&quot; src=&quot;/upload2009/200910/20091019193414271.jpg&quot; width=588 height=294&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019193422372.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;ZJQ500P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019193422372.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product Model&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019193447586.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ500P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019193447586.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ500 series DC contactor </title>
           <link>http://www.91way.com/info_en/6966.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:57:01</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZJQ5 * * (P) series DC contactors are suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;Rated current of main contact&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;Resistive load ¦Ó=1ms, 300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;dielectric strength&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;50Hz 1000V AC 1min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;Action Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;Action characteristics&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;1 million times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=181&gt;
&lt;DIV&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=374 colSpan=8&gt;
&lt;DIV&gt;Rated voltage of coil and contact (V)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;DIV&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=46&gt;
&lt;DIV&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;DIV&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=107&gt;
&lt;DIV&gt;two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;zero point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=46&gt;
&lt;DIV&gt;zero point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;DIV&gt;zero point eight five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;DIV&gt;zero point eight two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;DIV&gt;zero point four five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=556 colSpan=9&gt;
&lt;DIV&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ5XXP contact can be equipped with a closed baffle to prevent dust.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101919299915.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 294px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ500 series DC contactor&quot; src=&quot;/upload2009/200910/2009101919299915.jpg&quot; width=588 height=294&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019192918204.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;ZJQ500 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192918204.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019192924967.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ500 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019192924967.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ400 series DC contactor </title>
           <link>http://www.91way.com/info_en/6965.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZJQ400 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJQ400 series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 1300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD width=82&gt;thirty-six&lt;/TD&gt;
&lt;TD width=63&gt;forty&lt;/TD&gt;
&lt;TD width=63&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD width=67&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD width=82&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ4XXP contact can be equipped with a closed baffle to prevent dust.&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;Exterior installation diagram&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;&lt;A href=&quot;/upload2009/200910/20091019192420474.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 313px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ400 series DC contactor&quot; src=&quot;/upload2009/200910/20091019192420474.jpg&quot; width=612 height=313&gt;&lt;/A&gt;&lt;BR&gt;Circuit schematic&lt;/SPAN&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;SPAN&gt;&lt;A href=&quot;/upload2009/200910/20091019192447333.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJQ400 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192447333.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;ZJQ400 series DC contactor&lt;BR&gt;&lt;/SPAN&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ400P series DC contactor </title>
           <link>http://www.91way.com/info_en/6964.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:45</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ400 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJQ400P series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 1300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD width=63&gt;forty&lt;/TD&gt;
&lt;TD width=63&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD width=67&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ4XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;ZJQ400P series DC contactor exterior installation diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101919206247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 313px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ400P series DC contactor&quot; src=&quot;/upload2009/200910/2009101919206247.jpg&quot; width=612 height=313&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019192013732.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJQ400P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192013732.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ300P series DC contactor </title>
           <link>http://www.91way.com/info_en/6963.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:37</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ3 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJQ300P series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD width=49&gt;twenty-four&lt;/TD&gt;
&lt;TD width=49&gt;thirty&lt;/TD&gt;
&lt;TD width=78&gt;thirty-six&lt;/TD&gt;
&lt;TD width=63&gt;forty&lt;/TD&gt;
&lt;TD width=63&gt;forty-eight&lt;/TD&gt;
&lt;TD width=49&gt;seventy-two&lt;/TD&gt;
&lt;TD width=68&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD width=78&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ3XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101919152608.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ300P series DC contactor&quot; src=&quot;/upload2009/200910/2009101919152608.jpg&quot; width=680 height=250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019191514842.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJQ300P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019191514842.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019191531878.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ300P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019191531878.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ300 series DC contactor </title>
           <link>http://www.91way.com/info_en/6962.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Purpose:&lt;BR&gt;The ZJQ300 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJQ300 series DC contactor&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;&lt;TD2&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;&lt;BR&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ3XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;ZJQ300 series DC contactor exterior installation diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019191044894.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ300 series DC contactor&quot; src=&quot;/upload2009/200910/20091019191044894.jpg&quot; width=680 height=250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019191111307.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJQ300 series DC contactor circuit diagram&quot; src=&quot;/upload2009/200910/20091019191111307.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019191121388.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ300 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019191121388.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJQ300 series DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6961.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:20</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Usage conditions of ZJWH200A DC contactor&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior Installation Drawing of ZJWH200A DC Contactor&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019184844486.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 279px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184844486.jpg&quot; width=612 height=279&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019184857751.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWH200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184857751.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101918494563.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH200A DC Contactor&quot; src=&quot;/upload2009/200910/2009101918494563.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6960.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:12</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZJW200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;&lt;TD2&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;&lt;BR&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019184528424.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184528424.jpg&quot; width=553 height=260&gt;&lt;/A&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019184536439.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of ZJW200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184536439.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019184551745.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW200A DC Contactor&quot; src=&quot;/upload2009/200910/20091019184551745.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJW200A DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ400D type DC contactor </title>
           <link>http://www.91way.com/info_en/6959.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:56:04</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ400D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 400A&lt;BR&gt;The maximum allowable current is 4le for 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point three&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;
&lt;TD&gt;zero point two one&lt;/TD&gt;
&lt;TD width=36&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101918401808.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 421px; HEIGHT: 262px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJ400D DC contactor&quot; src=&quot;/upload2009/200910/2009101918401808.jpg&quot; width=421 height=262&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101918406861.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJ400D DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101918406861.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019184026152.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJ400D DC Contactor&quot; src=&quot;/upload2009/200910/20091019184026152.jpg&quot; width=411 height=193&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ200 series DC contactor </title>
           <link>http://www.91way.com/info_en/6958.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:55</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ2 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=205&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=354&gt;twelve&lt;/TD&gt;
&lt;TD width=44&gt;twenty-four&lt;/TD&gt;
&lt;TD width=44&gt;thirty&lt;/TD&gt;
&lt;TD width=82&gt;thirty-six&lt;/TD&gt;
&lt;TD width=63&gt;forty&lt;/TD&gt;
&lt;TD width=63&gt;forty-eight&lt;/TD&gt;
&lt;TD width=44&gt;seventy-two&lt;/TD&gt;
&lt;TD width=67&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=354&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD width=82&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ2XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019183648311.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 293px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ200 series DC contactor&quot; src=&quot;/upload2009/200910/20091019183648311.jpg&quot; width=550 height=293&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019183655462.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;ZJQ200 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019183655462.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101918375907.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ200 series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101918375907.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ600 series DC contactor </title>
           <link>http://www.91way.com/info_en/6957.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:47</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ600 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD width=82&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD width=67&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD width=82&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ6XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019183332151.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 268px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ600 series DC contactor&quot; src=&quot;/upload2009/200910/20091019183332151.jpg&quot; width=660 height=268&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019183337147.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJQ600 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019183337147.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019183344157.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ600 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019183344157.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A-2 type DC contactor </title>
           <link>http://www.91way.com/info_en/6956.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:39</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWT00A-2 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019182711518.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 287px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW100A-2 DC contactor&quot; src=&quot;/upload2009/200910/20091019182711518.jpg&quot; width=550 height=287&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019182723467.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 339px; HEIGHT: 174px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJW100A-2 DC contactor&quot; src=&quot;/upload2009/200910/20091019182723467.jpg&quot; width=339 height=174&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019182730391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 133px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW100A-2 DC Contactor&quot; src=&quot;/upload2009/200910/20091019182730391.jpg&quot; width=360 height=133&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH200A-2T type DC contactor </title>
           <link>http://www.91way.com/info_en/6955.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:31</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZJWH200A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJWH200A-2T DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019174610461.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH200A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019174610461.jpg&quot; width=660 height=295&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019174616129.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWH200A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019174616129.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019174629383.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH200A-2T DC Contactor&quot; src=&quot;/upload2009/200910/20091019174629383.jpg&quot; width=374 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ600P series DC contactor </title>
           <link>http://www.91way.com/info_en/6954.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:22</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ ZJQ600 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 300A&lt;BR&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;BR&gt;1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZJQ600P series DC contactor usage conditions&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;ZJQ600P series DC contactor appearance installation diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019174149963.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 268px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ600P series DC contactor&quot; src=&quot;/upload2009/200910/20091019174149963.jpg&quot; width=660 height=268&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019174155681.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJQ600P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019174155681.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009101917422191.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;ZJQ600P series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101917422191.jpg&quot; width=302 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6953.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:14</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWH400A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJWH400A DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 400A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019171931614.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 512px; HEIGHT: 344px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH400A DC contactor&quot; src=&quot;/upload2009/200910/20091019171931614.jpg&quot; width=512 height=344&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019171943510.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWH400A DC contactor&quot; src=&quot;/upload2009/200910/20091019171943510.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091019171951429.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH400A DC Contactor&quot; src=&quot;/upload2009/200910/20091019171951429.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT100A type DC contactor </title>
           <link>http://www.91way.com/info_en/6952.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:55:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZJWT100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJWT100A DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/20091019171451850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWT100A DC contactor&quot; src=&quot;/upload2009/200910/20091019171451850.jpg&quot; width=680 height=260&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009101917153872.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWT100A DC contactor&quot; src=&quot;/upload2009/200910/2009101917153872.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200910/20091019171513915.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWT100A DC Contactor&quot; src=&quot;/upload2009/200910/20091019171513915.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ600D DC contactor </title>
           <link>http://www.91way.com/info_en/5624.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:58</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZJ600D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJ600D DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 600A&lt;BR&gt;The maximum allowable current is 4le for 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point three&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;
&lt;TD&gt;zero point two one&lt;/TD&gt;
&lt;TD width=36&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ200D DC contactor </title>
           <link>http://www.91way.com/info_en/5623.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:49</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ200D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJ200D DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;BR&gt;The maximum allowable current is 4le for 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point three&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;
&lt;TD&gt;zero point two one&lt;/TD&gt;
&lt;TD width=69&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ100D DC contactor </title>
           <link>http://www.91way.com/info_en/5622.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:41</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJ100D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;BR&gt;The maximum allowable current is 4le for 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point three&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;
&lt;TD&gt;zero point two one&lt;/TD&gt;
&lt;TD width=73&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Service conditions for ZJ100D DC contactor&lt;BR&gt;&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ50A DC contactor </title>
           <link>http://www.91way.com/info_en/5621.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:32</pubDate>
           <comments></comments>
           <description>The ZJ50A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJ50A DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 50A&lt;BR&gt;The maximum allowable current is 4le for 5 seconds&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;300,000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;zero point three&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;
&lt;TD&gt;zero point two one&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point zero eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ100 series DC contactor </title>
           <link>http://www.91way.com/info_en/5620.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:24</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;&lt;BR&gt;The ZJQ100 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;/P&gt;
&lt;P&gt;Brief Technical Parameters&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=193&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load ¦Ó=1ms, 150A&lt;BR&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min; 1200A 5% 30sec; 1800A 2% 20min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=8&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=8&gt;Cold suction voltage: ¡Û 66% Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=8&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=8&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=8&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=293&gt;twelve&lt;/TD&gt;
&lt;TD width=49&gt;twenty-four&lt;/TD&gt;
&lt;TD width=49&gt;thirty&lt;/TD&gt;
&lt;TD width=119&gt;thirty-six&lt;/TD&gt;
&lt;TD width=70&gt;forty&lt;/TD&gt;
&lt;TD width=70&gt;forty-eight&lt;/TD&gt;
&lt;TD width=49&gt;seventy-two&lt;/TD&gt;
&lt;TD width=74&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=293&gt;two point five&lt;/TD&gt;
&lt;TD&gt;one point five&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD width=119&gt;zero point nine&lt;/TD&gt;
&lt;TD&gt;zero point eight five&lt;/TD&gt;
&lt;TD&gt;zero point eight two&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ1XXP contact can be equipped with a closed baffle to prevent dust.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;SPAN&gt;&lt;BR&gt;Terms of Use&lt;/SPAN&gt;&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;ZJQ100 series DC contactor exterior installation diagram&lt;/SPAN&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091019182914125.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 292px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ100 series DC contactor&quot; src=&quot;/upload2009/200910/20091019182914125.jpg&quot; width=600 height=292&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJQ100 series DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW500A DC contactor </title>
           <link>http://www.91way.com/info_en/5619.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:16</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW500A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=3 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;&lt;TD2&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 500A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;TD2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;&lt;BR&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200942211575665.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 240px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW500A DC contactor&quot; src=&quot;/uploadfiles/200904/200942211575665.jpg&quot; width=680 height=240&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009422115712509.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJW500A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009422115712509.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;Product model meaning&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/2009422115722221.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW500A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009422115722221.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJW500A DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH400A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/5618.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:54:08</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWH400A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJWH400A-2T DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=3 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 400A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942211542857.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 672px; HEIGHT: 278px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH400A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/200942211542857.jpg&quot; width=672 height=278&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009422115410770.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJWH400A-2T DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/2009422115410770.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;ZJWH400A-2T DC contactor model meaning&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/2009422115444850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH400A-2T DC Contactor&quot; src=&quot;/uploadfiles/200904/2009422115444850.jpg&quot; width=374 height=134&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW400A DC contactor </title>
           <link>http://www.91way.com/info_en/5292.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:59</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW400A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 400A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT200L DC contactor </title>
           <link>http://www.91way.com/info_en/5291.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:51</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWT200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200948161540165.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 280px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWT200L DC contactor&quot; src=&quot;/uploadfiles/200904/200948161540165.jpg&quot; width=680 height=280&gt;&lt;/A&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200948161550323.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;ZJWT200L DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/200948161550323.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/200948161558129.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWT200L DC Contactor&quot; src=&quot;/uploadfiles/200904/200948161558129.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJWT200L DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT200A DC contactor </title>
           <link>http://www.91way.com/info_en/5290.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:43</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;/P&gt;
&lt;P&gt;The ZJWT200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;/P&gt;
&lt;P&gt;Brief Technical Parameters&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD width=36&gt;seventy-two&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=36&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;SPAN&gt;Terms of Use&lt;/SPAN&gt;&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;Exterior installation diagram&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/200948161215857.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 240px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWT200A DC contactor&quot; src=&quot;/uploadfiles/200904/200948161215857.jpg&quot; width=550 height=240&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/200948161246565.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWT200A DC Contactor&quot; src=&quot;/uploadfiles/200904/200948161246565.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]GSZ2 series single pole normally closed DC contactor </title>
           <link>http://www.91way.com/info_en/5041.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:35</pubDate>
           <comments></comments>
           <description>GSZ2 series single pole normally closed DC contactor&lt;BR&gt;&lt;BR&gt;The GSZ2 series single pole normally open DC contactor is suitable for starting and stopping battery vehicles, as well as power switching and uninterruptible power supply systems in fields such as electric forklifts, traction locomotives, telecommunications, and computers. The product design complies with GB/T14048.1 &quot;General Principles for Low Voltage Switchgear and Control Equipment&quot;, the Ministry of Machinery standard JB2286-78 &quot;Basic Technical Conditions for Traction Electrical Appliances&quot;, JB3974-85 &quot;Basic Technical Conditions for DC Electrical Appliances for Battery Vehicles&quot;, and the Ministry of Posts and Telecommunications standards YD/T585-92 &quot;Distribution Equipment for Communication&quot; and YD/T512-92 &quot;Technical Conditions for Telegraph Power Equipment&quot;.&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The action mechanism is a direct acting type, and the contact is a double break point; Natural arc extinguishing; Small size, light weight, low power consumption, and high reliability.&lt;BR&gt;&lt;BR&gt;Working and installation conditions&lt;BR&gt;Environmental temperature: -25 to+40 ¡æ, with an average of no more than+35 ¡æ over 24 hours&lt;BR&gt;Relative humidity:+20 ¡æ up to 90%&lt;BR&gt;Fixed vibration frequency: 1-50Hz (frequency 1-10Hz, amplitude 25/f; frequency 10-50Hz, amplitude 250/f)&lt;BR&gt;Impact acceleration: 30m/s&lt;BR&gt;Installation direction: Any&lt;BR&gt;Installation method: screw installation&lt;BR&gt;Applicable working system: uninterrupted working system (DC-1)&lt;BR&gt;&lt;BR&gt;Ordering Instructions&lt;BR&gt;Full models and names of contactors&lt;BR&gt;Voltage specification of control coil&lt;BR&gt;Order Quantity&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]GSZ2 series single pole normally open DC contactor </title>
           <link>http://www.91way.com/info_en/5040.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:26</pubDate>
           <comments></comments>
           <description>GSZ2 series single pole normally open DC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH100A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/5001.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:18</pubDate>
           <comments></comments>
           <description>&lt;A href=&quot;/uploadfiles/200904/200943114721987.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 375px; HEIGHT: 135px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH100A-2T DC Contactor&quot; src=&quot;/uploadfiles/200904/200943114721987.jpg&quot; width=375 height=135&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;purpose&lt;BR&gt;The ZJWH100A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJWH100A-2T DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=194&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=234&gt;twelve&lt;/TD&gt;
&lt;TD width=67&gt;twenty-four&lt;/TD&gt;
&lt;TD width=67&gt;thirty&lt;/TD&gt;
&lt;TD width=67&gt;thirty-six&lt;/TD&gt;
&lt;TD width=67&gt;forty&lt;/TD&gt;
&lt;TD width=67&gt;forty-eight&lt;/TD&gt;
&lt;TD width=67&gt;sixty&lt;/TD&gt;
&lt;TD width=64&gt;seventy-two&lt;/TD&gt;
&lt;TD width=71&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=64&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Usage conditions of ZJWH100A-2T DC contactor&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Installation diagram of ZJWH100A-2T DC contactor appearance&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200943114638588.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 624px; HEIGHT: 279px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH100A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/200943114638588.jpg&quot; width=624 height=279&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094311479855.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJWH100A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/20094311479855.jpg&quot; width=257 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJWH100A-2T DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH100A DC contactor </title>
           <link>http://www.91way.com/info_en/5000.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:10</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJWH100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=178&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=153&gt;twelve&lt;/TD&gt;
&lt;TD width=82&gt;twenty-four&lt;/TD&gt;
&lt;TD width=82&gt;thirty&lt;/TD&gt;
&lt;TD width=82&gt;thirty-six&lt;/TD&gt;
&lt;TD width=82&gt;forty&lt;/TD&gt;
&lt;TD width=82&gt;forty-eight&lt;/TD&gt;
&lt;TD width=82&gt;sixty&lt;/TD&gt;
&lt;TD width=64&gt;seventy-two&lt;/TD&gt;
&lt;TD width=78&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=64&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200943113731866.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 238px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJWH100A DC contactor&quot; src=&quot;/uploadfiles/200904/200943113731866.jpg&quot; width=554 height=238&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200943113738321.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=0 hspace=0 alt=&quot;ZJWH100A DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/200943113738321.jpg&quot; width=170 height=177&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;ZJWH100A DC contactor model&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200943113749776.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJWH100A DC Contactor&quot; src=&quot;/uploadfiles/200904/200943113749776.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT50A DC contactor </title>
           <link>http://www.91way.com/info_en/4999.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:53:02</pubDate>
           <comments></comments>
           <description>The ZJWT50A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=174&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 50A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=260&gt;twelve&lt;/TD&gt;
&lt;TD width=64&gt;twenty-four&lt;/TD&gt;
&lt;TD width=64&gt;thirty&lt;/TD&gt;
&lt;TD width=64&gt;thirty-six&lt;/TD&gt;
&lt;TD width=64&gt;forty&lt;/TD&gt;
&lt;TD width=64&gt;forty-eight&lt;/TD&gt;
&lt;TD width=64&gt;sixty&lt;/TD&gt;
&lt;TD width=54&gt;seventy-two&lt;/TD&gt;
&lt;TD width=93&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD width=93&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJNT-100A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4998.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical parameters of ZJNT-100A DC electromagnetic contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=3 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177&gt;ZJN100A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Coil maintains current ()&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Product Model&lt;/TD&gt;
&lt;TD colSpan=2&gt;Coil voltage (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=534&gt;twenty-four&lt;/TD&gt;
&lt;TD width=261&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN100A&lt;/TD&gt;
&lt;TD width=534&gt;zero point eight three&lt;/TD&gt;
&lt;TD width=261&gt;one point six five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A&lt;/TD&gt;
&lt;TD width=534&gt;zero point seven three&lt;/TD&gt;
&lt;TD width=261&gt;one point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: The coil parameters can be changed according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJN-200A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4997.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:43</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177&gt;ZJN100A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Coil maintains current ()&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Product Model&lt;/TD&gt;
&lt;TD colSpan=2&gt;Coil voltage (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=534&gt;twenty-four&lt;/TD&gt;
&lt;TD width=261&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN100A&lt;/TD&gt;
&lt;TD width=534&gt;zero point eight three&lt;/TD&gt;
&lt;TD width=261&gt;one point six five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A&lt;/TD&gt;
&lt;TD width=534&gt;zero point seven three&lt;/TD&gt;
&lt;TD width=261&gt;one point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: The coil parameters can be changed according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200943105337391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJN-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/200943105337391.jpg&quot; width=660 height=388&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Coil schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200943105410743.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=0 hspace=0 alt=&quot;ZJN-200A DC Electromagnetic Contactor Wiring Diagram&quot; src=&quot;/uploadfiles/200904/200943105410743.jpg&quot; width=554 height=112&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200943105631657.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJN-200A DC Electromagnetic Contactor&quot; src=&quot;/uploadfiles/200904/200943105631657.jpg&quot; width=553 height=103&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;ZJN-200A DC Electromagnetic Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJNT-200A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4996.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:34</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177&gt;ZJN100A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Coil maintains current ()&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Product Model&lt;/TD&gt;
&lt;TD colSpan=2&gt;Coil voltage (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=534&gt;twenty-four&lt;/TD&gt;
&lt;TD width=261&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN100A&lt;/TD&gt;
&lt;TD width=534&gt;zero point eight three&lt;/TD&gt;
&lt;TD width=261&gt;one point six five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A&lt;/TD&gt;
&lt;TD width=534&gt;zero point seven three&lt;/TD&gt;
&lt;TD width=261&gt;one point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: The coil parameters can be changed according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Exterior installation diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009439157631.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJNT-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/2009439157631.jpg&quot; width=660 height=388&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Coil schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094391527331.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJNT-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/20094391527331.jpg&quot; width=554 height=112&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094391537102.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJNT-200A DC Electromagnetic Contactor&quot; src=&quot;/uploadfiles/200904/20094391537102.jpg&quot; width=553 height=103&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJNT-200A DC Electromagnetic Contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJN-100A type DC contactor </title>
           <link>http://www.91way.com/info_en/4995.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:26</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=177&gt;ZJN100A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A main contact current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load ¦Ó=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=2&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=2&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=2&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Coil maintains current ()&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Product Model&lt;/TD&gt;
&lt;TD colSpan=2&gt;Coil voltage (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=534&gt;twenty-four&lt;/TD&gt;
&lt;TD width=261&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN100A&lt;/TD&gt;
&lt;TD width=534&gt;zero point eight three&lt;/TD&gt;
&lt;TD width=261&gt;one point six five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ZJN200A&lt;/TD&gt;
&lt;TD width=534&gt;zero point seven three&lt;/TD&gt;
&lt;TD width=261&gt;one point four five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;Note: The coil parameters can be changed according to user requirements&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Installation diagram of ZJN-100A DC contactor&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094391146685.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJN-100A DC contactor&quot; src=&quot;/uploadfiles/200904/20094391146685.jpg&quot; width=660 height=388&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Coil schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094391153822.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=0 hspace=0 alt=&quot;ZJN-100A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/20094391153822.jpg&quot; width=554 height=112&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094391211276.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJN-100A DC Contactor&quot; src=&quot;/uploadfiles/200904/20094391211276.jpg&quot; width=553 height=103&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJN-100A DC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A DC contactor </title>
           <link>http://www.91way.com/info_en/4994.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:18</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=236&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 100A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold state suction voltage: £¾ 66%&lt;BR&gt;Cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;twelve&lt;/TD&gt;
&lt;TD width=67&gt;twenty-four&lt;/TD&gt;
&lt;TD width=67&gt;thirty&lt;/TD&gt;
&lt;TD width=67&gt;thirty-six&lt;/TD&gt;
&lt;TD width=67&gt;forty&lt;/TD&gt;
&lt;TD width=67&gt;forty-eight&lt;/TD&gt;
&lt;TD width=67&gt;sixty&lt;/TD&gt;
&lt;TD width=64&gt;seventy-two&lt;/TD&gt;
&lt;TD width=71&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=64&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Usage conditions of ZJW100A DC contactor&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ;&lt;BR&gt;2. Altitude: 0-2000 meters;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;BR&gt;5. Impact: 30m/s2;&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Installation diagram of ZJW100A DC contactor appearance&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009439758128.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW100A DC contactor&quot; src=&quot;/uploadfiles/200904/2009439758128.jpg&quot; width=524 height=270&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009439810873.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJW100A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009439810873.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product Model&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009439820296.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW100A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009439820296.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJW100A DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW50A DC contactor </title>
           <link>http://www.91way.com/info_en/4993.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:09</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZJW50A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Brief Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=182&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load ¦Ó=1ms, 50A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=9&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=9&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=9&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=9&gt;Resistive load (¦Ó=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The coil consumes less than 15 watts of power,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=9&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=246&gt;twelve&lt;/TD&gt;
&lt;TD width=67&gt;twenty-four&lt;/TD&gt;
&lt;TD width=67&gt;thirty&lt;/TD&gt;
&lt;TD width=67&gt;thirty-six&lt;/TD&gt;
&lt;TD width=67&gt;forty&lt;/TD&gt;
&lt;TD width=67&gt;forty-eight&lt;/TD&gt;
&lt;TD width=67&gt;sixty&lt;/TD&gt;
&lt;TD width=64&gt;seventy-two&lt;/TD&gt;
&lt;TD width=71&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;zero point nine eight&lt;/TD&gt;
&lt;TD&gt;zero point five eight&lt;/TD&gt;
&lt;TD&gt;zero point four five&lt;/TD&gt;
&lt;TD&gt;zero point three five&lt;/TD&gt;
&lt;TD&gt;zero point three two&lt;/TD&gt;
&lt;TD&gt;zero point two eight&lt;/TD&gt;
&lt;TD&gt;zero point two five&lt;/TD&gt;
&lt;TD width=64&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point one eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Appearance and installation diagram of ZJW50A DC contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009439416696.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 281px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJW50A DC contactor&quot; src=&quot;/uploadfiles/200904/2009439416696.jpg&quot; width=553 height=281&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009439429800.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;ZJW50A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009439429800.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Product model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009439443137.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJW50A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009439443137.jpg&quot; width=337 height=151&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]NR200A DC contactor </title>
           <link>http://www.91way.com/info_en/4991.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:52:00</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The NR200A series DC contactor is suitable for supplying power to automotive air conditioning, batteries, or rectifier power sources; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Technical parameters of NR200A DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=234&gt;Rated current of main contact&lt;/TD&gt;
&lt;TD colSpan=3&gt;Resistive load ¦Ó=1ms, 200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;dielectric strength&lt;/TD&gt;
&lt;TD colSpan=3&gt;50Hz 1000V AC 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action Time&lt;/TD&gt;
&lt;TD colSpan=3&gt;Cold suction time: ¡Û 30ms, release: ¡Û 30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Action characteristics&lt;/TD&gt;
&lt;TD colSpan=3&gt;Cold suction voltage: ¡Û 66%, cold release voltage: ¡Û 30%, ¡Ú 5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD colSpan=3&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD colSpan=3&gt;Resistive load (¦Ó=1ms): 20000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;The power consumption of the coil is less than 15 watts,&lt;BR&gt;Maximum current of coil (A)&lt;/TD&gt;
&lt;TD colSpan=3&gt;Rated voltage of coil and contact (V)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;twelve&lt;/TD&gt;
&lt;TD width=124&gt;twenty-four&lt;/TD&gt;
&lt;TD width=126&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;zero point three eight&lt;/TD&gt;
&lt;TD width=124&gt;zero point three one&lt;/TD&gt;
&lt;TD width=126&gt;zero point one six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25~+40 ¡æ; &amp;nbsp;&lt;BR&gt;2. Altitude: 0-2000 meters; &amp;nbsp;&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: 90%; &amp;nbsp;&lt;BR&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &amp;nbsp;&lt;BR&gt;5. Impact: 30m/s2&lt;BR&gt;6. Installation direction: Any&lt;BR&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;BR&gt;8. Work schedule: 8H long hours&lt;BR&gt;&lt;BR&gt;Circuit schematic diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/2009438734719.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=0 hspace=0 alt=&quot;NR200A DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/2009438734719.jpg&quot; width=198 height=187&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200904/2009438744319.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 336px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;Model Description of NR200A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009438744319.jpg&quot; width=336 height=145&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;NR200A DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC2 series electromagnetic DC contactor 160¡«400A</title>
           <link>http://www.91way.com/info_en/4604.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:52</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 1306px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of QCC2 series electromagnetic DC contactor&quot; src=&quot;/uploadfiles/200901/2009110105914758.jpg&quot; width=680 height=1306&gt;&lt;/P&gt;
&lt;P align=center&gt;QCC2 series electromagnetic DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ22-63 type DC contactor </title>
           <link>http://www.91way.com/info_en/4485.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:44</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;CZ22-63 DC contactor model and its meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200809/2008917153528920.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/uploadfiles/200809/2008917153528920.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;scope of application&lt;BR&gt;The CZ22-63 DC contactor is suitable for connecting and disconnecting circuits, as well as frequently starting and controlling DC motors in DC power systems with DC voltage up to 440V and current up to 63A.&lt;BR&gt;meet the standard&lt;BR&gt;Equivalent to IEC60947-4;&lt;BR&gt;Compliant with GB14048.4.&lt;BR&gt;working conditions&lt;BR&gt;The altitude does not exceed 2000m; the upper limit of the surrounding air temperature is+40 ¡æ, and the average value within 24 hours does not exceed+35 ¡æ, with a lower limit of -5 ¡æ; When the relative humidity of the air does not exceed 50% at a maximum temperature of+40 ¡æ, and the monthly average minimum temperature does not exceed+25 ¡æ, the average maximum relative humidity of the month does not exceed 90%; The pollution level is level 3; Places without significant shaking and impact vibration; In a medium without explosive hazards, and without any gas or conductive dust that can corrode metals or damage insulation in the medium; There are rain and snow protection equipment and places without sufficient water vapor.&lt;BR&gt;Specification and classification&lt;BR&gt;Basic specifications: 63A.&lt;BR&gt;According to the voltage level of the control coil, there are five specifications: AC50HZ, 380V, 220V, 127V, 110V, and 36V;&lt;BR&gt;rated duty&lt;BR&gt;eight-hour day Uninterrupted work system; Intermittent cycle work system:&lt;BR&gt;The maximum operating frequency at a load factor of 40% is 1200h-1 for DC-2 and DC-4 usage categories, 600h-1 for DC-3, and 300 h-1 for DC-5.&lt;BR&gt;Short term working system: The standard values for the contact electrification time are 10, 30, 60, and 90 minutes.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200809/2008917153539924.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 352px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZ22-63 DC contactor&quot; src=&quot;/uploadfiles/200809/2008917153539924.jpg&quot; width=535 height=352&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CZ22-63 type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ200A,200S,200D series DC contactor </title>
           <link>http://www.91way.com/info_en/4453.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:35</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;The ZJ200A, 200S, 200D series DC contactors are suitable for electronic control systems such as electric scooters, electric forklifts, excavators, automotive air conditioners, communication power supplies, uninterruptible power supplies, etc.&lt;BR&gt;&lt;BR&gt;Usage conditions:&lt;BR&gt;1. Environmental temperature: -25 to+40 ¡æ&lt;BR&gt;2. Relative humidity:+20 ¡æ up to 98%&lt;BR&gt;3. Fixed vibration frequency: 1-50Hz Acceleration: 10 meters/s2&lt;BR&gt;4. Impact acceleration: 30 meters per second&lt;BR&gt;5. Altitude: 2000 meters&lt;BR&gt;6. Installation direction: Contact points facing upwards&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200809/200891123123763.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 195px&quot; border=0 hspace=0 alt=&quot;ZJ200A, 200S, 200D series DC contactor model description&quot; src=&quot;/uploadfiles/200809/200891123123763.jpg&quot; width=300 height=195&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;LINE-HEIGHT: 150%; WIDTH: 680px; BORDER-COLLAPSE: collapse; FONT-SIZE: 12px&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;Preface&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;parameter name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;Product coil rated voltage type parameter requirements&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;12V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;24V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;30V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;36V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;40V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;48V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;48A(V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated control power supply voltage of coil&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Maximum starting current of coil&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;&amp;lt;5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Maximum holding current of coil in cold state&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;zero point five five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;zero point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;zero point two five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;zero point two zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;zero point one seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;zero point one four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;zero point one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;zero point one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated operating voltage of contact circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated working current of contact circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Control the fluctuation range of power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;20%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Maximum breaking capacity of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (¦Ó=0.001 seconds)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Contact voltage drop under 100A current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;MV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;&amp;lt;60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Pull in time under rated control power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;¡Ü30&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Release time under rated control power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;¡Ü30&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Maximum bounce time of the contact point&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Insulation resistance value (cold state)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;M¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;&amp;gt;20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;AC insulation electrical strength&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;50 weeks/second 1500V 1 minute&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;ZJ200S auxiliary contact resistive load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;ZJ200A/ZJ200D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;¦Ó=0.001 seconds 10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;ZJ200S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;¦Ó=0.001 seconds 5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Work Specifications&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;continuous&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Action characteristics&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;DIV align=center&gt;70% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/SPAN&gt;
&lt;P align=center&gt;&lt;BR&gt;ZJ200A, 200S, 200D series DC contactors&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ-524 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4436.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:26</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 540px&quot; border=0 cellSpacing=0 cellPadding=0 width=540 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;Outline drawing 1 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211751267.jpg&quot; width=150 height=150&gt;&lt;BR&gt;Product One&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;Outline drawing 2 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211759980.jpg&quot; width=150 height=150&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Product 2&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;Outline drawing 3 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=2 src=&quot;/uploadfiles/200809/20089721187745.jpg&quot; width=150 height=150&gt;&lt;BR&gt;Product Three&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 4&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211815476.jpg&quot; width=150 height=150&gt;&lt;BR&gt;Product 4&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 5&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211822569.jpg&quot; width=150 height=150&gt;&lt;BR&gt;Product 5&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 6&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211832256.jpg&quot; width=150 height=150&gt;&lt;BR&gt;Product 6&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;TABLE style=&quot;WIDTH: 540px&quot; border=0 cellSpacing=0 cellPadding=0 width=540 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;ZJQ-524 series DC electromagnetic contactor accessories&quot; vspace=2 src=&quot;/uploadfiles/200809/200897211849965.jpg&quot; width=150 height=150&gt;&lt;BR&gt;&lt;BR&gt;Product Seven&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; scope=row align=middle&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=0 width=1 bgColor=#e6e6e6 height=&quot;1%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=0 hspace=2 alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 7&quot; vspace=2 src=&quot;/uploadfiles/200809/20089721193108.jpg&quot; width=150 height=150&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Product 8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJH-200A(DZJ) type DC contactor </title>
           <link>http://www.91way.com/info_en/4252.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:18</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;The ZJH-200A (DZJ) DC contactor is suitable for various electronic control systems such as electric vehicles, automotive air conditioning, communication power supplies, and uninterruptible power supplies.&lt;BR&gt;&lt;BR&gt;Usage conditions:&lt;BR&gt;1. Environmental temperature: -25 to+40 ¡æ&lt;BR&gt;2. Relative humidity:+20 ¡æ up to 98%&lt;BR&gt;3. Fixed vibration frequency: 1-50Hz Acceleration: 10 meters/s2&lt;BR&gt;4. Impact acceleration: 30 meters per second&lt;BR&gt;5. Altitude: 2000 meters&lt;BR&gt;6. Installation direction: Contact points facing upwards&lt;BR&gt;&lt;BR&gt;The meaning of ZJH-200A (DZJ) type DC contactor model&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 210px&quot; border=0 hspace=0 alt=&quot;Model Description of ZJH-200A (DZJ) DC Contactor&quot; src=&quot;/uploadfiles/200808/200881002057323.jpg&quot; width=250 height=210&gt;&lt;BR&gt;&lt;BR&gt;Outline installation diagram and circuit schematic diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=259 vAlign=center align=middle&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 320px; HEIGHT: 331px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJH-200A (DZJ) DC contactor&quot; src=&quot;/uploadfiles/200808/20088100216718.jpg&quot; width=320 height=331&gt;&lt;/TD&gt;
&lt;TD height=259 vAlign=center align=right&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 199px&quot; border=0 hspace=0 alt=&quot;Contact diagram of ZJH-200A (DZJ) DC contactor&quot; src=&quot;/uploadfiles/200808/200881002116129.jpg&quot; width=200 height=199&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;ZJH-200A (DZJ) type DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;Preface&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;parameter name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;Product coil rated voltage type parameter requirements&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;12V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;24V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;30V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;36V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;48A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Rated control power supply voltage of coil&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Maximum starting current of coil&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&amp;lt;5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Maximum holding current of coil in cold state&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;zero point five five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;zero point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;zero point two five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;zero point one seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;zero point one six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Rated operating voltage of contact circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;forty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Rated working current of contact circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Control the fluctuation range of power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&#177;20%Us&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Maximum breaking capacity of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (¦Ó=0.001 seconds)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Contact voltage drop under 100A current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;MV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&amp;lt;60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Pull in time under rated control power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&amp;lt;30&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Release time under rated control power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&amp;lt;30&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Maximum bounce time of the contact point&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;MS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Insulation resistance value (cold state)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;M¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;&amp;gt;20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;AC insulation electrical strength&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;50Hz 1000V 1min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Auxiliary contact load current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;5A ¦Ó=0.001s (only products with &quot;S&quot; have this option) 24V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Electrical lifespan (&amp;pound;=0.001 seconds)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;1000 (¦Ó=0.001 seconds)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Work Specifications&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;continuous&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;
&lt;DIV align=center&gt;Action characteristics&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;75% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW type DC contactor </title>
           <link>http://www.91way.com/info_en/4251.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:10</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;CENTER&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Purpose:&lt;BR&gt;The ZJW type DC contactor is suitable for electric vehicles, communication power supplies, uninterruptible power supplies, and power system distribution centers.&lt;BR&gt;&lt;BR&gt;Usage conditions:&lt;BR&gt;1. Environmental temperature: -25 ¡æ to+40 ¡æ&lt;BR&gt;2. Relative humidity:+25 ¡æ up to 98%&lt;BR&gt;3. Fixed vibration frequency: 1-50HZ, acceleration: 10 meters per second 2&lt;BR&gt;4. Impact acceleration: 30 meters per second&lt;BR&gt;5. Altitude: 2000 meters&lt;BR&gt;&lt;BR&gt;Product model meaning&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=8 width=10&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=320 align=left&gt;
&lt;P&gt;Single pole on-off type:&lt;/P&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 156px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor model description 1&quot; src=&quot;/uploadfiles/200808/200881001355228.jpg&quot; width=250&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=278 align=left&gt;
&lt;P&gt;Bipolar on-off type:&lt;/P&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 141px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor model description 2&quot; src=&quot;/uploadfiles/200808/20088100144840.jpg&quot; width=250 height=141&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=320 align=left&gt;
&lt;P&gt;&lt;BR&gt;&lt;BR&gt;Double connected disconnect type:&lt;/P&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 142px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor model description 3&quot; src=&quot;/uploadfiles/200808/200881001416573.jpg&quot; width=250 height=142&gt;&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=278 align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=320&gt;External Installation Diagram&lt;/TD&gt;
&lt;TD width=278&gt;Circuit schematic&lt;/TD&gt;&lt;/TR&gt;&lt;/CENTER&gt;
&lt;TR&gt;
&lt;CENTER&gt;
&lt;TD width=320 align=left&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 273px; HEIGHT: 350px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor installation size 1&quot; src=&quot;/uploadfiles/200808/200881001428914.jpg&quot; width=273 height=350&gt;&lt;/TD&gt;&lt;/CENTER&gt;
&lt;TD height=426 vAlign=top rowSpan=2 align=right&gt;
&lt;P align=left&gt;Single pole single pass:&lt;/P&gt;
&lt;CENTER&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 95px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor wiring diagram 1&quot; src=&quot;/uploadfiles/200808/200881001436689.jpg&quot; width=200 height=95&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/CENTER&gt;
&lt;P align=left&gt;Bipolar on-off:&lt;/P&gt;
&lt;CENTER&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 98px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor wiring diagram 2&quot; src=&quot;/uploadfiles/200808/200881001446436.jpg&quot; width=200 height=98&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/CENTER&gt;
&lt;P align=left&gt;Dual connectivity disconnection:&lt;/P&gt;
&lt;CENTER&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 90px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor wiring diagram 3&quot; src=&quot;/uploadfiles/200808/20088100153665.jpg&quot; width=200 height=90&gt;&lt;/P&gt;&lt;/CENTER&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=left&gt;Wiring method, user instructions when ordering (internal or external)&lt;/P&gt;
&lt;P align=left&gt;Note: When wiring the contact circuit with a magnetic arc extinguishing device and the coil with a suppression circuit, attention should be paid to positive and negative polarity, and do not connect them incorrectly.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;CENTER&gt;
&lt;TR&gt;
&lt;TD width=320 align=left&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 277px; HEIGHT: 350px&quot; border=0 hspace=0 alt=&quot;ZJW type DC contactor installation size 2&quot; src=&quot;/uploadfiles/200808/200881001529563.jpg&quot; width=277 height=350&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=380 colSpan=2&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; HEIGHT: 350px&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; height=350&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=28 rowSpan=2 width=123 colSpan=2 align=middle&gt;Product performance parameters&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;ZJW&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;ZJWH&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;ZJWT&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=14 align=middle&gt;twelve&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;twenty-four&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;thirty&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;thirty-six&lt;/TD&gt;
&lt;TD width=24 align=middle&gt;forty&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;forty-eight&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;twelve&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;twenty-four&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;thirty&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;thirty-six&lt;/TD&gt;
&lt;TD width=21 align=middle&gt;forty&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;forty-eight&lt;/TD&gt;
&lt;TD width=21 align=middle&gt;twelve&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;twenty-four&lt;/TD&gt;
&lt;TD width=17 align=middle&gt;thirty&lt;/TD&gt;
&lt;TD width=21 align=middle&gt;thirty-six&lt;/TD&gt;
&lt;TD width=15 align=middle&gt;forty&lt;/TD&gt;
&lt;TD width=16 align=middle&gt;forty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=32 rowSpan=2 width=41 align=middle&gt;Coil power consumption&lt;/TD&gt;
&lt;TD width=80 align=middle&gt;100A&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=24 align=middle&gt;12W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;12W&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;11.5W&lt;/TD&gt;
&lt;TD width=21 align=middle&gt;12W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;12W&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;12&#215;2W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=80 align=middle&gt;200A&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=24 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;15.5W&lt;/TD&gt;
&lt;TD width=14 align=middle&gt;-&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;15W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;15W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;15W&lt;/TD&gt;
&lt;TD width=21 align=middle&gt;15W&lt;/TD&gt;
&lt;TD width=35 align=middle&gt;15.5W&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;15.5&#215;2W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 rowSpan=2 width=123 colSpan=2 align=middle&gt;Contact resistive load&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;ZJW100A&lt;/TD&gt;
&lt;TD width=98 colSpan=3 align=middle&gt;ZJW200A&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;ZJWH100A&lt;/TD&gt;
&lt;TD width=95 colSpan=3 align=middle&gt;ZJWH200A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;ZJWT100A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;ZJWT200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;100A&lt;/TD&gt;
&lt;TD width=98 colSpan=3 align=middle&gt;200A&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;100A&lt;/TD&gt;
&lt;TD width=95 colSpan=3 align=middle&gt;200A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;100A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=32 rowSpan=2 width=41 align=middle&gt;Contact voltage&lt;/TD&gt;
&lt;TD width=80 align=middle&gt;No magnetic arc extinguishing&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;Maximum 36V&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;Maximum 36V&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;Maximum 36V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=80 align=middle&gt;Magnetic arc extinguishing&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;Maximum 60V&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;Maximum 60V&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;Maximum 60V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;Contact voltage drop&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;&amp;lt;60mv&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;&amp;lt;60mv&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;&amp;lt;60mv&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=14 width=123 colSpan=2 align=middle&gt;Suction time&lt;/TD&gt;
&lt;TD height=14 width=188 colSpan=6 align=middle&gt;30ms&lt;/TD&gt;
&lt;TD height=14 width=185 colSpan=6 align=middle&gt;30ms&lt;/TD&gt;
&lt;TD height=14 width=114 colSpan=6 align=middle&gt;30ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=32 rowSpan=2 width=41 align=middle&gt;release time&lt;/TD&gt;
&lt;TD width=80 align=middle&gt;Without inhibition&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;15ms&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;15ms&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;15ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=80 align=middle&gt;With inhibition&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;60ms&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;60ms&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;60ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=32 rowSpan=2 width=41 align=middle&gt;Action characteristics&lt;/TD&gt;
&lt;TD width=80 align=middle&gt;pull-in voltage &lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;85% US suction&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;85% US suction&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;85% US suction&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=80 align=middle&gt;release voltage&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;Not less than 5% Us&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;Not less than 5% Us&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;Not less than 5% Us&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;Cold state insulation resistance&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;&amp;gt;20 M¦¸&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;&amp;gt;20 M¦¸&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;&amp;gt;20 M¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;AC insulation electrical strength&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;50Hz 1000 1min&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;50Hz 1000 1min&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;50Hz 1000 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;mechanical life&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;1 million times&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;1 million times&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;1 million times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;Voltage lifespan (¦Ó=0.001S)&lt;/TD&gt;
&lt;TD width=188 colSpan=6 align=middle&gt;1000 times&lt;/TD&gt;
&lt;TD width=185 colSpan=6 align=middle&gt;1000 times&lt;/TD&gt;
&lt;TD width=114 colSpan=6 align=middle&gt;1000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=123 colSpan=2 align=middle&gt;Work Specifications&lt;/TD&gt;
&lt;TD width=487 colSpan=18 align=middle&gt;Long term work (note: 12V products should be started at 24V, and 12V can be maintained for long-term work)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=32 rowSpan=2 width=123 colSpan=2 align=middle&gt;weight&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;ZJW100A&lt;/TD&gt;
&lt;TD width=98 colSpan=3 align=middle&gt;ZJW200A&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;ZJWH100A&lt;/TD&gt;
&lt;TD width=95 colSpan=3 align=middle&gt;ZJWH200A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;ZJWT100A&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;ZJWT200A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;0.4Kg&lt;/TD&gt;
&lt;TD width=98 colSpan=3 align=middle&gt;0.75Kg&lt;/TD&gt;
&lt;TD width=88 colSpan=3 align=middle&gt;0.45Kg&lt;/TD&gt;
&lt;TD width=95 colSpan=3 align=middle&gt;0.85Kg&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;1Kg&lt;/TD&gt;
&lt;TD width=56 colSpan=3 align=middle&gt;1.8Kg&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/CENTER&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;ZJW type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ type DC contactor </title>
           <link>http://www.91way.com/info_en/2338.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:51:02</pubDate>
           <comments></comments>
           <description>scope of application&lt;BR&gt;The ZJQ type DC contactor is suitable for supplying power to batteries or rectifier power sources, and is also used to operate power switches for traction, pump motors, and other electric vehicles.&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Environmental temperature: -25 ¡æ to+40 ¡æ&lt;BR&gt;2. Altitude: 2000 meters&lt;BR&gt;3. Maximum relative humidity at 25 ¡æ: up to 90%&lt;BR&gt;4. Fixed vibration: 10-50HZ, 10 meters per second&lt;BR&gt;5. Impact: 30 meters per second&lt;BR&gt;6. Installation direction: Contact points facing upwards&lt;BR&gt;&lt;BR&gt;Basic parameters of ZJQ type DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;Preface&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;29%&quot;&gt;parameter name&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;unit&lt;/TD&gt;
&lt;TD colSpan=7&gt;Product coil rated voltage type parameter requirements&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;12V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;18V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;24V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;30V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;36V&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;48V&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;one&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated control power supply voltage of coil&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;eighteen&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;twenty-four&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;thirty&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;thirty-six&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;forty-eight&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=13 width=&quot;5%&quot;&gt;two&lt;/TD&gt;
&lt;TD height=13 width=&quot;29%&quot;&gt;Maximum starting current of coil&lt;/TD&gt;
&lt;TD height=13 width=&quot;5%&quot;&gt;A&lt;/TD&gt;
&lt;TD height=13 colSpan=7&gt;&amp;lt;5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;three&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;29%&quot;&gt;Maximum holding current of coil in cold state&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;A&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;2.7&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;2.5&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;1.8&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;1.5&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;0.9&#215;2&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;0.8&#215;2&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;D-type coil&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;0.85&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;0.85&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;0.70&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;0.75&#215;2&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;0.75&#215;2&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;0.6&#215;2&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;A-type coil&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;four&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated operating voltage of contact circuit&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;V&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;twenty-four&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;twenty-four&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;twenty-four&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;thirty&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;thirty-six&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;forty-eight&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;five&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current of contact circuit&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;A&lt;/TD&gt;
&lt;TD colSpan=7&gt;Starting with 3 characters is 150 amps, starting with 6 characters is 300 amps&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;six&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Control the fluctuation range of power supply voltage&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;-&lt;/TD&gt;
&lt;TD colSpan=7&gt;&#177;20%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;seven&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Maximum breaking capacity of contacts&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;A&lt;/TD&gt;
&lt;TD colSpan=7&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (¦Ó=0.001 seconds)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;eight&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Contact voltage drop under 100A current&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;MV&lt;/TD&gt;
&lt;TD colSpan=7&gt;&amp;lt;60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;nine&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Pull in time under rated control power supply voltage&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;MS&lt;/TD&gt;
&lt;TD colSpan=7&gt;¡Ü 30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;ten&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Release time under rated control power supply voltage&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;MS&lt;/TD&gt;
&lt;TD colSpan=7&gt;¡Ü30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;eleven&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Maximum bounce time of the contact point&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;MS&lt;/TD&gt;
&lt;TD colSpan=7&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Insulation resistance value (cold state)&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;M¦¸&lt;/TD&gt;
&lt;TD colSpan=7&gt;&amp;gt;20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;thirteen&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;AC insulation electrical strength&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;-&lt;/TD&gt;
&lt;TD colSpan=7&gt;50 weeks/second 1500 volts for 1 minute&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;fourteen&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Electrical lifespan (&amp;pound;=0.001 seconds)&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;ten thousand times&lt;/TD&gt;
&lt;TD colSpan=7&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;fifteen&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;mechanical life&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;ten thousand times&lt;/TD&gt;
&lt;TD colSpan=7&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;sixteen&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Work Specifications&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;-&lt;/TD&gt;
&lt;TD colSpan=7&gt;continuous&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;5%&quot;&gt;seventeen&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Action characteristics&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;V&lt;/TD&gt;
&lt;TD colSpan=7&gt;70% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;installation dimensions&lt;FONT color=#000000&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200705/200753110424416.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 552px; HEIGHT: 406px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZJQ type DC contactor&quot; src=&quot;/uploadfiles/200705/200753110424416.jpg&quot; width=552 height=406&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJQ type DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/FONT&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC1 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/2307.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:54</pubDate>
           <comments></comments>
           <description>The QCC1 series DC electromagnetic contactor is used in applications with vibration, as a power circuit with frequent switching of DC rated voltage below 1500 volts and rated current within 6-35 amperes. It is used for the closing and opening of electric motors for compressed air or ventilation fans on DC overhead standard rail electric locomotives.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201511/20151106224224185.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 336px&quot; border=0 hspace=0 alt=&quot;QCC1 series DC electromagnetic contactor model description&quot; src=&quot;/upload2015/201511/20151106224224185.jpg&quot; width=505 height=336&gt;&lt;/A&gt;&lt;BR&gt;Structural features:&lt;BR&gt;The QCC1 series DC electromagnetic contactor consists of three main parts: magnetic system, contact system, and arc extinguishing device, which are installed on the same base plate. The contact system works in the power circuit, with a large distance between the contacts, good insulation between various parts, easy installation and maintenance, and safe and reliable use.&lt;BR&gt;&lt;BR&gt;Main technical data:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated voltage (volts)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Attraction coil voltage (volts)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Supporting electromechanical vehicle&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Overall dimensions&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=left&gt;QCC1-7&lt;BR&gt;QCC1-8&lt;BR&gt;QCC1-9&lt;BR&gt;QCC1-10&lt;BR&gt;QCC1-11&lt;BR&gt;QCC1-12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=left&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=left&gt;35 16 6 35 16 35&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=left&gt;-50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=left&gt;80T 100T 150T subway electric locomotive&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=left&gt;340*82*360&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201511/20151106224243427.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 559px; HEIGHT: 404px&quot; border=0 hspace=0 alt=&quot;Technical parameters of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224243427.jpg&quot; width=559 height=404&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201511/20151106224305937.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 556px; HEIGHT: 726px&quot; border=0 hspace=0 alt=&quot;Dimensions of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224305937.jpg&quot; width=556 height=726&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201511/20151106224325646.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 571px; HEIGHT: 341px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224325646.jpg&quot; width=571 height=341&gt;&lt;/A&gt;&lt;BR&gt;QCC1 series DC electromagnetic contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCK,QCC series DC contactor </title>
           <link>http://www.91way.com/info_en/2306.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:45</pubDate>
           <comments></comments>
           <description>QCK, QCC series DC contactors&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC31 DC electromagnetic contactor 1500V/600A 800A</title>
           <link>http://www.91way.com/info_en/2188.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:36</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;QCC31 DC electromagnetic contactor is used as a non-polar switch in industrial and mining electric locomotives, subways, light rail vehicles, railway traction locomotives, and passenger vehicles, and as a tap changer contactor in the main and auxiliary circuits.&lt;BR&gt;&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD width=82&gt;one thousand and five hundred&lt;/TD&gt;
&lt;TD width=102&gt;Closing time (mS)&lt;/TD&gt;
&lt;TD width=121&gt;¡Ü100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Rated current (A)&lt;/TD&gt;
&lt;TD width=82&gt;600£¬800&lt;/TD&gt;
&lt;TD width=102&gt;Disconnect time (mS)&lt;/TD&gt;
&lt;TD width=121&gt;¡Ü50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Maximum operating voltage (V)&lt;/TD&gt;
&lt;TD width=82&gt;one thousand and eight hundred&lt;/TD&gt;
&lt;TD width=102&gt;Number of auxiliary contacts&lt;/TD&gt;
&lt;TD width=121&gt;2NC+2NC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Switching ability (A)&lt;/TD&gt;
&lt;TD width=82&gt;4le&lt;/TD&gt;
&lt;TD width=102&gt;drive mechanism&lt;/TD&gt;
&lt;TD width=121&gt;electromagnetic&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD width=82&gt;3*10&lt;SUP&gt;six&lt;/SUP&gt;&lt;/TD&gt;
&lt;TD width=102&gt;Weight (kg)&lt;/TD&gt;
&lt;TD width=121&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD width=82&gt;ten&lt;SUP&gt;four&lt;/SUP&gt;&lt;/TD&gt;
&lt;TD width=102&gt;Dimensions (mm)&lt;/TD&gt;
&lt;TD width=121&gt;383*81.5*375&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;QCC31 DC Electromagnetic Contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ20-1000 type DC contactor </title>
           <link>http://www.91way.com/info_en/1438.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1. Scope of application:&lt;BR&gt;&lt;BR&gt;The CZ20-1000 DC contactor is suitable for use in DC power circuits with a rated working voltage of 250V and a rated working current of 1000A and below. It is used as a switching and breaking circuit to frequently start and stop DC motors, as well as reversing or reversing braking equipment for DC motors. Can replace low CZ18 series and high current DC contactors imported from abroad.&lt;BR&gt;&lt;BR&gt;2. Model meaning:&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061114175043659.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 212px&quot; border=0 hspace=0 alt=&quot;Model Description of CZ20-1000 DC Contactor&quot; src=&quot;/uploadfiles/200611/20061114175043659.jpg&quot; width=400 height=212&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product Features:&lt;BR&gt;1. Equipped with the latest arc extinguishing device, it has strong arc extinguishing capability.&lt;BR&gt;2. Strong overcurrent capability and reliable performance.&lt;BR&gt;3. The structure is simple and easy to replace.&lt;BR&gt;&lt;BR&gt;4. Main technical parameters:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/20061114175112921.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 249px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CZ20-1000 DC contactor&quot; src=&quot;/uploadfiles/200611/20061114175112921.jpg&quot; width=600 height=249&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;CZ20-1000 DC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CN series AC/DC contactors </title>
           <link>http://www.91way.com/info_en/1181.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:20</pubDate>
           <comments></comments>
           <description>CN series AC/DC contactors&lt;BR&gt;&lt;BR&gt;&#183;Obtained certifications such as 3C, CE, UL, TUV, CSA, etc.&lt;BR&gt;&#183;Compliant with standards such as GB, IEC, BS, JIS, NEMA, etc.&lt;BR&gt;&#183;Contactors can be equipped with thermal overload protection relays, mechanical interlock modules, auxiliary contact modules, coil drive devices, surge suppressors, etc., to expand product functionality.&lt;BR&gt;&#183;Easy to install, with two installation methods: screw fixation and rail installation.&lt;BR&gt;&#183;The contactor terminal has an IP20 safety cover design, which can protect personal safety.&lt;BR&gt;&#183;The auxiliary contact adopts a dual contact design, which ensures reliable operation.&lt;BR&gt;&#183;The contactor housing is made of engineering plastic, which can resist external impacts.&lt;BR&gt;&#183;The overall appearance has a high degree of sealing, which can prevent external foreign objects from affecting the operation of the contactor.&lt;BR&gt;&#183;The insulation level of the coil is high to avoid interlayer circuit breaks&lt;BR&gt;&lt;BR&gt;CN series AC/DC contactors&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ21 series DC contactor </title>
           <link>http://www.91way.com/info_en/764.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:12</pubDate>
           <comments></comments>
           <description>1¡¢ Scope of application&lt;BR&gt;CZ21-16, CZ21-40, CZ22-63 DC contactors are mainly used for long-distance connection and disconnection of DC power lines with rated voltage up to 440V and rated heating current up to 25A, 40A, and 63A, respectively. And it is suitable for frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;BR&gt;2¡¢ Structural features&lt;BR&gt;The contactors are derived from CJ10-20A, CJ20-40, and CJ20-63A, with a vertical structure of two layers, a direct acting structure, a bridge shape, and double break silver cadmium oxide points. The main contact and arc extinguishing system of the permanent magnet constant magnetic field magnetic blowing clay arc extinguishing system are located on the upper layer of the contactor, with good arc extinguishing performance, long electrical life, reliable breaking ability, and any current below; The &quot;E&quot; type direct acting electromagnet is equipped with a buffer spring, which is beneficial for improving the service life of the machine. The attraction coil can be AC or DC, and the voltage level can be selected by the user according to their needs; The bridge shaped double breakpoint silver alloy auxiliary contact is located on both sides of the contactor. The overall structure of the contactor is very compact.&lt;BR&gt;Due to the use of permanent magnet constant magnetic field for arc extinguishing, the main contact terminal must be connected to the DC power supply with &quot;+&quot; and &quot;-&quot; polarity.&lt;BR&gt;&lt;BR&gt;3¡¢ Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=48 align=middle&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=53 align=middle&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD rowSpan=2 width=53 align=middle&gt;Rated current (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=47 align=middle&gt;
&lt;DIV align=justify&gt;Constant number of main contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3 align=middle&gt;auxiliary contact&lt;/TD&gt;
&lt;TD rowSpan=2 width=88 align=middle&gt;Rated breaking capacity of main contact (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=59 align=middle&gt;
&lt;P&gt;Operation rate (times/h)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60 align=middle&gt;Mechanical lifespan (10000 cycles)&lt;/TD&gt;
&lt;TD rowSpan=2 width=67 align=middle&gt;Electrical lifespan (10000 cycles)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=25 align=middle&gt;Chang Fen&lt;/TD&gt;
&lt;TD width=23 align=middle&gt;Chang He&lt;/TD&gt;
&lt;TD width=57 align=middle&gt;Rated heating current (A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;CZ21-16&lt;/TD&gt;
&lt;TD rowSpan=3&gt;four hundred and forty&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;one thousand and two hundred&lt;/TD&gt;
&lt;TD align=middle&gt;three hundred&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;CZ221-40&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;CZ22-63&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;two hundred and fifty-two&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 299px&quot; border=0 hspace=0 alt=&quot;CZ21 series DC contactor installation size 1&quot; src=&quot;/uploadfiles/200610/20061028192456637.jpg&quot; width=500 height=299&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 301px&quot; border=0 hspace=0 alt=&quot;CZ21 series DC contactor installation size 2&quot; src=&quot;/uploadfiles/200610/2006102819254169.jpg&quot; width=500 height=301&gt;&lt;BR&gt;&lt;BR&gt;CZ21 series DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ18 series DC contactor </title>
           <link>http://www.91way.com/info_en/763.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:50:04</pubDate>
           <comments></comments>
           <description>1¡¢ Scope of application&lt;BR&gt;The CZ18 series DC contactor is mainly used for long-distance connection and disconnection of DC power lines with rated voltage up to 440V and rated heating up to 1600A. And it is suitable for frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 207px&quot; border=0 hspace=0 alt=&quot;CZ18 series DC contactor model description&quot; src=&quot;/uploadfiles/200610/200610281975782.bmp&quot; width=360 height=207&gt;&lt;BR&gt;&lt;BR&gt;3¡¢ Structural features&lt;BR&gt;The CZ18 series DC contactor adopts a snap on electromagnet that rotates at a winding angle, with a single winding attraction coil; The main contact is a single break point finger structure, connected in series, series magnetic blowing, and a ceramic arc extinguishing cover to form an arc extinguishing system, which is fixed one in front and one behind the electromagnetic system on the large base plate; The bridge type double break auxiliary head, which is normally divided and normally combined into one group, is arranged on both sides of the electromagnet; The front wiring of contactors with rated currents of 40A and 80A does not have a live magnetic system, while contactors with rated currents of 160A and above have a back wiring and a live magnetic system, so they must be installed on an insulation board.&lt;BR&gt;The whole system contactor has the advantages of long service life, good arc extinguishing performance, and easy use and maintenance&lt;BR&gt;&lt;BR&gt;4¡¢ Main technical parameters of CZ18 series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;18%&quot; align=middle&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot; align=middle&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot; align=middle&gt;Rated current (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot; align=middle&gt;
&lt;DIV align=justify&gt;Constant number of main contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=22 colSpan=3 align=middle&gt;auxiliary contact&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;Rated breaking capacity of main contact (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;Operation rate (times/h)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;Mechanical lifespan (10000 cycles)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot; align=middle&gt;Electrical lifespan (10000 cycles)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;wiring method&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15 width=&quot;5%&quot; align=middle&gt;Chang Fen&lt;/TD&gt;
&lt;TD width=&quot;5%&quot; align=middle&gt;Chang He&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;Rated heating current (A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-40/10&lt;/TD&gt;
&lt;TD rowSpan=17&gt;four hundred and forty&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot; align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;5%&quot; align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;5%&quot; align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=4 align=middle&gt;six&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;8%&quot; align=middle&gt;one thousand and two hundred&lt;/TD&gt;
&lt;TD rowSpan=7 width=&quot;9%&quot; align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD rowSpan=7 width=&quot;10%&quot; align=middle&gt;fifty&lt;/TD&gt;
&lt;TD rowSpan=7 width=&quot;9%&quot; align=middle&gt;Pre board wiring&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-40/20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-80/10&lt;/TD&gt;
&lt;TD rowSpan=2 align=middle&gt;eighty&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=2 align=middle&gt;three hundred and twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-80/20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-160/10&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=13 align=middle&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;six hundred and forty&lt;/TD&gt;
&lt;TD rowSpan=13 align=middle&gt;six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-160B/20&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-160B/20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-315/10&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;three hundred and fifteen&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;one thousand two hundred and sixty&lt;/TD&gt;
&lt;TD rowSpan=10 align=middle&gt;three hundred&lt;/TD&gt;
&lt;TD rowSpan=10 align=middle&gt;thirty&lt;/TD&gt;
&lt;TD rowSpan=10 align=middle&gt;Rear panel connection&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-315B/10&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-315B-20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-630/10&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;two thousand five hundred and twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-630B/10&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-630B/20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-1000/10&lt;/TD&gt;
&lt;TD rowSpan=3 align=middle&gt;one thousand&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD rowSpan=2 align=middle&gt;four thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-1000B/10&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-1000B/20&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;
&lt;TD rowSpan=2 align=middle&gt;six thousand and four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;CZ18-1600B/10&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;CZ18 series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 386px&quot; border=0 hspace=0 alt=&quot;CZ18 series DC contactor installation size 1&quot; src=&quot;/uploadfiles/200610/2006102819719882.jpg&quot; width=500 height=386&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 381px&quot; border=0 hspace=0 alt=&quot;CZ18 series DC contactor installation size 2&quot; src=&quot;/uploadfiles/200610/2006102819734261.jpg&quot; width=500 height=381&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD height=&quot;13&quot;&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 244px&quot; border=0 hspace=0 alt=&quot;CZ18 series DC contactor installation size 3&quot; src=&quot;/uploadfiles/200610/2006102819745739.jpg&quot; width=600 height=244&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ series DC contactor </title>
           <link>http://www.91way.com/info_en/761.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:49:55</pubDate>
           <comments></comments>
           <description>The MZJ series DC contactor is designed for remote connection and disconnection of DC power lines with rated voltage up to 220V and rated current up to 600A. It is suitable for controlling the frequent starting, stopping, reversing, and reverse braking of DC motors. Widely used in industrial and mining enterprises, airports, dock stations, ports, electric scooters, forklifts, as well as passenger and freight vehicles.&lt;BR&gt;&lt;BR&gt;The model and specification codes of the contactor are represented as follows:&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 140px&quot; border=0 hspace=0 alt=&quot;MZJ series DC contactor model description&quot; src=&quot;/uploadfiles/200610/20061028192145697.jpg&quot; width=360 height=140&gt;&lt;BR&gt;&lt;BR&gt;3¡¢ Structural features&lt;BR&gt;The main contact is a bridge type, double break point, silver alloy contact, and direct acting structure; The suction coil of the helical electromagnetic coil is a series double winding structure. It has the advantages of small size, light weight, low power consumption, large suction capacity, and reliable operation.&lt;BR&gt;&lt;BR&gt;4¡¢ Technical parameters of MZJ series DC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR bgColor=#ffffff&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot; align=middle&gt;
&lt;P&gt;Product Code&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;Rated voltage of attraction coil (V)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;Maximum current of coil at rated voltage&lt;/P&gt;
&lt;P&gt;£¨A£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot; align=middle&gt;
&lt;DIV align=justify&gt;
&lt;P&gt;Rated voltage of main contact&lt;/P&gt;
&lt;P&gt;£¨V£©&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=22 align=middle&gt;Rated load of main circuit&lt;/TD&gt;
&lt;TD height=22 colSpan=2 align=middle&gt;+Maximum operating voltage in hot state at 20+5 ¡æ (V)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot; align=middle&gt;Electrical lifespan (10000 cycles)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15 width=&quot;9%&quot; align=middle&gt;Time constant (S ¡Ü)&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;pickup&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;release&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=15&gt;001&lt;BR&gt;002&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;zero point five&lt;/TD&gt;
&lt;TD align=middle&gt;24/48&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;zero point zero zero five&lt;/TD&gt;
&lt;TD align=middle&gt;fifteen point nine&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;six point five&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=18&gt;
&lt;P&gt;003&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;forty&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point three two&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot; align=middle&gt;zero point zero one&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five point nine&lt;/TD&gt;
&lt;TD align=middle&gt;fourteen point nine&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=18&gt;004&lt;/TD&gt;
&lt;TD&gt;forty-eight&lt;/TD&gt;
&lt;TD align=middle&gt;zero point three&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one&lt;/TD&gt;
&lt;TD align=middle&gt;seventeen&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;005&lt;/TD&gt;
&lt;TD&gt;ninety-six&lt;/TD&gt;
&lt;TD align=middle&gt;zero point two&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero zero five&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-two&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-five&lt;/TD&gt;
&lt;TD align=middle&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=18&gt;006&lt;BR&gt;007&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD align=middle&gt;zero point five&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero one&lt;/TD&gt;
&lt;TD align=middle&gt;fifteen point nine&lt;/TD&gt;
&lt;TD align=middle&gt;eight point five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=70&gt;008&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero one&lt;/TD&gt;
&lt;TD align=middle&gt;nineteen point eight&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;ten point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=33&gt;009&lt;/TD&gt;
&lt;TD&gt;twenty-seven&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four five&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero one&lt;/TD&gt;
&lt;TD align=middle&gt;seventeen point eight&lt;/TD&gt;
&lt;TD align=middle&gt;nine point five&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=33&gt;010&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero one&lt;/TD&gt;
&lt;TD align=middle&gt;eight point four&lt;/TD&gt;
&lt;TD align=middle&gt;four point two&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 275px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of MZJ series DC contactors&quot; src=&quot;/uploadfiles/200610/2006102819212303.jpg&quot; width=500 height=275&gt;&lt;BR&gt;&lt;BR&gt;MZJ series DC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ0 series DC contactor </title>
           <link>http://www.91way.com/info_en/295.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-6-10 10:49:45</pubDate>
           <comments></comments>
           <description>1¡¢ Scope of application&lt;BR&gt;The CZ0 series DC contactor (hereinafter referred to as the contactor) is mainly used for frequent connection and disconnection of DC circuits over long distances, such as controlling DC motors.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008527223330788.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 276px; HEIGHT: 201px&quot; border=0 hspace=0 alt=&quot;CZ0 series DC contactor model description&quot; src=&quot;/uploadfiles/200805/2008527223330788.gif&quot; width=276 height=201&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;3¡¢ Structural features&lt;BR&gt;The rated operating frequency of contactors with normally open main contacts of CZ0-150 and below is 1200/hour, with a mechanical life of 5 million cycles and an electrical life of 500000 cycles.&lt;BR&gt;The rated operating frequency of CZ0-150 and below contactors with normally closed main contacts and CZ0-250 and above contactors is 600 times/hour, with a mechanical life of 3 million times and an electrical life of 300000 times.&lt;BR&gt;The critical breaking capacity of the main contact of the contactor at rated voltage is 0.2 times the rated current. Therefore, when using it, be careful not to reduce the working current too much. For CZ0-40, in order to ensure reliable arc extinguishing when breaking small currents, the rated current of its arc extinguishing coil is divided into six types: 1.5, 2.5, 5, 10, 20, and 40A, for selection.&lt;BR&gt;The breaking capacity of the main contact of the contactor at rated voltage and the distance of the arc beyond the arc extinguishing chamber are shown in Figure 1, Figure 2, and Table 1.&lt;BR&gt;5. The thermal stability of the contactor can withstand 7 times the rated current for 10 seconds, and the dynamic stability can withstand 20 times the rated current.&lt;BR&gt;6. The parameters of the contactor are shown in Figure 3, Figure 4, and Table 2.&lt;BR&gt;7. For contactors with series connected double winding attraction coils (which have three terminals A, B, and C), their control power must be connected to both ends of A and B, otherwise the coils will be burned.&lt;BR&gt;&lt;BR&gt;CZ0 series DC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-F115(LC1-F115) series AC contactor </title>
           <link>http://www.91way.com/info_en/29728.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:43</pubDate>
           <comments></comments>
           <description>Scope of application&lt;BR&gt;The LC1-F series AC contactor (hereinafter referred to as the contactor) is suitable for AC 50Hz or 60Hz, and can be used in circuits with special coils ranging from 40-400Hz, voltage up to 600V, and current up to 630A. It is used for the connection and disconnection of the main circuit, and is suitable for frequent starting and control of electric motors; Can be used in conjunction with various relays and other electrical equipment, for controlling various electrical devices, motors, and circuits. It can also be combined with auxiliary contact groups, air delay heads, mechanical interlocks, etc. to form mechanical interlock contactors, star delta starters, and can be combined with thermal relays to form magnetic starters.&lt;BR&gt;&lt;BR&gt;Model and its meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250830113800330.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 121px; WIDTH: 520px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CJX2-F115 (LC1-F115) series AC contactor model description&quot; src=&quot;/upload2025/202508/20250830113800330.jpg&quot; width=520 height=121&gt;&lt;/A&gt;&lt;BR&gt;Technical parameters of CJX2-F115 (LC1-F115) series AC contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Model Type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F115&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F185&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F225&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F265&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F330&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;LC1-F500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;LC1-F630&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;Rated working current le (A)&lt;BR&gt;Rated operational current&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;380V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and sixty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;eighty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;four hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;380V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;fifty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and thirty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and forty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;one thousand eight hundred and eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;forty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;sixty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;sixty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;eighty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;ninety-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and thirty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;Controllable three-phase squirrel cage motor ****** power&lt;BR&gt;Pe(kw) Controlled squirrel-cage asnchronous motor's max power pe(kw)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;380V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;three hundred and thirty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and twenty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and thirty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;four hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;380V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and twenty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Agreed heating current (A)&lt;BR&gt;Convention althermal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;two hundred and seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;three hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;seven hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Rated operating voltage (Ue) Vrated operational voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=center&gt;380, 660&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Rated insulation voltage (Ui)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=center&gt;six hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Compliant with standard operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=center&gt;IEC947¡¢GB14048&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Electric lifespan times&lt;BR&gt;Electrical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;60&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;50&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;30&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;20&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Operating frequency h-1&lt;BR&gt;Swiching frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;AC-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Electric lifespan times&lt;BR&gt;Electrical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;15&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;8&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Operating frequency h-1&lt;BR&gt;Swiching frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Mechanical lifespan (&#215; 10)&lt;SUP&gt;six&lt;/SUP&gt;)Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;3&#215;10&lt;SUP&gt;six&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;1&#215;10&lt;SUP&gt;six&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;auxiliary contact&lt;BR&gt;Auxiiary contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Agreed heating current (1st)&lt;BR&gt;Aconveentional&lt;BR&gt;thermal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Electric lifespan times&lt;BR&gt;Electrical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-15&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;60&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=3&gt;
&lt;P align=center&gt;50&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;30&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;20&#215;10&lt;SUP&gt;four&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;AC-13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CCJ8 series AC contactor </title>
           <link>http://www.91way.com/info_en/29480.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CCJ8 series AC contactor&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3H450F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29436.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:27</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3H450F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816133308608.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3H450F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816133308608.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY17F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29435.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:18</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY17F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816133140353.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY17F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816133140353.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-85F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29434.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-85F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816132934152.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-85F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816132934152.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY33F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29433.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:07:02</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY33F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816132738881.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY33F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816132738881.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-83F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29432.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-83F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816132556638.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-83F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816132556638.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-1D1H400F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29431.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:45</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1D1H400F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816132028148.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1D1H400F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816132028148.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-1D400F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29430.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-1D400F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816131823456.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-1D400F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816131823456.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY45F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29429.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY45F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816131542544.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY45F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816131542544.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-80F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29428.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-80F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816131228339.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-80F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816131228339.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY42F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29427.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:11</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY42F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816131057340.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY42F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816131057340.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY35F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29426.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:06:03</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY35F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816130903412.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY35F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816130903412.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY34F type Busbar contactor </title>
           <link>http://www.91way.com/info_en/29425.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:54</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY34F Busbar contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816130719335.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY34F Busbar contactor&quot; src=&quot;/upload2025/202508/20250816130719335.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-50M type sealed three-phase contactor </title>
           <link>http://www.91way.com/info_en/29424.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:46</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-50M sealed three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816130035208.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-50M sealed three-phase contactor&quot; src=&quot;/upload2025/202508/20250816130035208.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3Z120M type sealed three-phase contactor </title>
           <link>http://www.91way.com/info_en/29423.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3Z120M Sealed Three Phase Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816125849158.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3Z120M sealed three-phase contactor&quot; src=&quot;/upload2025/202508/20250816125849158.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3Z90M type sealed three-phase contactor </title>
           <link>http://www.91way.com/info_en/29422.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:29</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3Z90M Sealed Three Phase Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816125721301.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3Z90M sealed three-phase contactor&quot; src=&quot;/upload2025/202508/20250816125721301.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3Z60M type sealed three-phase contactor </title>
           <link>http://www.91way.com/info_en/29421.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3Z60M Sealed Three Phase Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816125546576.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3Z60M sealed three-phase contactor&quot; src=&quot;/upload2025/202508/20250816125546576.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3H120M type sealed three-phase contactor </title>
           <link>http://www.91way.com/info_en/29420.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:12</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3H120M Sealed Three Phase Contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816121445314.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3H120M sealed three-phase contactor&quot; src=&quot;/upload2025/202508/20250816121445314.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-45FH,JQ-46FH,JQ-47FH type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29419.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:05:03</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-45FH, JQ-46FH, JQ-47FH three-phase contactors&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816121107533.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-45FH, JQ-46FH, JQ-47FH three-phase contactors&quot; src=&quot;/upload2025/202508/20250816121107533.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JCQ-3H400F,JCQ-3H500F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29418.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JCQ-3H400F, JCQ-3H500F three-phase contactors&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816120841211.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JCQ-3H400F and JCQ-3H500F three-phase contactors&quot; src=&quot;/upload2025/202508/20250816120841211.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-QY47F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29417.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-QY47F three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816120504608.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-QY47F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816120504608.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-38F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29416.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-38F type three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816120313906.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-38F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816120313906.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-47F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29415.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:29</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-47F three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816115934262.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-47F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816115934262.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-46F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29414.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-46F three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816115758654.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-46F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816115758654.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-45F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29413.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:12</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-45F three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816115600924.png&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 161px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JQ-45F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816115600924.png&quot; width=680 height=161&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-37F,JQ-37FH type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29412.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:04:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-37F, JQ-37FH three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816113823630.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-37F and JQ-37FH three-phase contactors&quot; src=&quot;/upload2025/202508/20250816113823630.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-28F,JQ-28FH type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29411.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-28F, JQ-28FH three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816113610520.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-28F and JQ-28FH three-phase contactors&quot; src=&quot;/upload2025/202508/20250816113610520.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-36F,JQ-36FH type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29410.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:46</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-36F, JQ-36FH three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816113331473.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-36F and JQ-36FH three-phase contactors&quot; src=&quot;/upload2025/202508/20250816113331473.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-79F type three-phase contactor </title>
           <link>http://www.91way.com/info_en/29409.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-79F three-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816113054419.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-79F three-phase contactor&quot; src=&quot;/upload2025/202508/20250816113054419.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-30M single-phase contactor </title>
           <link>http://www.91way.com/info_en/29408.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:29</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-30M single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816112156905.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-30M single-phase contactor&quot; src=&quot;/upload2025/202508/20250816112156905.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-61M single-phase contactor </title>
           <link>http://www.91way.com/info_en/29407.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-61M single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816112006924.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-61M single-phase contactor&quot; src=&quot;/upload2025/202508/20250816112006924.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-49F,JQ-49FH single-phase contactor </title>
           <link>http://www.91way.com/info_en/29406.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:12</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-49F, JQ-49FH single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816111823163.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-49F and JQ-49FH single-phase contactors&quot; src=&quot;/upload2025/202508/20250816111823163.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-52F,JQ-52FH single-phase contactor </title>
           <link>http://www.91way.com/info_en/29405.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:03:03</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-52F, JQ-52FH single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816111639308.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-52F and JQ-52FH single-phase contactors&quot; src=&quot;/upload2025/202508/20250816111639308.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-35F,JQ-35FH single-phase contactor </title>
           <link>http://www.91way.com/info_en/29404.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-35F, JQ-35FH single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816111431699.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-35F and JQ-35FH single-phase contactors&quot; src=&quot;/upload2025/202508/20250816111431699.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-34F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29403.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-34F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816111220262.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-34F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816111220262.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-91F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29402.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-91F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105951420.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-91F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105951420.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-48F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29401.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-48F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105758803.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-48F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105758803.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-400D single-phase contactor </title>
           <link>http://www.91way.com/info_en/29400.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-400D single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105531189.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-400D single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105531189.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-200D single-phase contactor </title>
           <link>http://www.91way.com/info_en/29399.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-200D single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105433141.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-200D single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105433141.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-56F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29398.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:02:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-56F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105229733.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-56F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105229733.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-39F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29397.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-39F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816105023926.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-39F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816105023926.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-40 series single-phase contactor JQ-40F,JQ-41F,JQ-42F</title>
           <link>http://www.91way.com/info_en/29396.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:48</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-40 series single-phase contactor&lt;BR&gt;&lt;BR&gt;JQ-40F,JQ-41F,JQ-42F&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816104625193.png&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JQ-40 series single-phase contactor&quot; src=&quot;/upload2025/202508/20250816104625193.png&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-81F single-phase contactor </title>
           <link>http://www.91way.com/info_en/29395.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JQ-81F single-phase contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202508/20250816104254320.png&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 204px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JQ-81F single-phase contactor&quot; src=&quot;/upload2025/202508/20250816104254320.png&quot; width=680 height=204&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7676F type three-phase contactor (7676)} </title>
           <link>http://www.91way.com/info_en/29394.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:31</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7676F Three Phase Contactor (7676)&lt;BR&gt;Product specifications: 012Vd. c., 024V. d.c, 027Vd. c&lt;BR&gt;Load: 60Vd. c., 200Va. c., 380Va. c., 115/200Va. c&lt;BR&gt;Product size: 47.8mm * 40mm * 61.2mm&lt;BR&gt;Product weight: ¡Ü 230g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7676F three-phase contactor (7676) is a three-phase AC relay with strong overload capacity and high reliability, widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/R21028-2013.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7663F type three-phase contactor (7663)} </title>
           <link>http://www.91way.com/info_en/29392.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:23</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7663F Three Phase Contactor (7663)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c., 115/200Va. c&lt;BR&gt;Product size: 80.8mm * 95mm * 85mm&lt;BR&gt;Product weight: ¡Ü 750g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;JQ-7663F three-phase contactor (7663) is a three-phase AC contactor with a load current of 25A. It has the characteristics of multiple contact groups and high reliability. Widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20962-2013. 4. Can be used interchangeably with 25710BM.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]Three phase contactor (EN_1) </title>
           <link>http://www.91way.com/info_en/29391.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:14</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7629F Three phase Contactor (7629)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c, 5 * 10 ^ 3 times&lt;BR&gt;Product size: 87.5mm * 44mm * 70mm&lt;BR&gt;Product weight: ¡Ü 260g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;JQ-7629F three-phase contactor (7629) is a three-phase AC contactor with the characteristics of simple structure, large load design margin, and high reliability. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20739-2011.</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7671F type three-phase contactor (7671)} </title>
           <link>http://www.91way.com/info_en/29390.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:01:03</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7671F Three Phase Contactor (7671)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c, 115/200Va. c., 220/380Va. c&lt;BR&gt;Product size: 74mm * 93mm * 65.6mm&lt;BR&gt;Product weight: ¡Ü 600g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7671F three-phase contactor (7671) is a three-phase AC contactor with a main contact load current of 25A. It has the characteristics of multiple contact groups, long service life, strong overload capacity, and high reliability. Widely used in aviation, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21008-2013. 4. Can be used interchangeably with 25510BM.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7674F type three-phase contactor (7674)} </title>
           <link>http://www.91way.com/info_en/29389.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:55</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7674F Three phase Contactor (7674)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c., 60Vd. c., 380Va. c., 115/200Va. c&lt;BR&gt;Product size: 87.5mm * 44mm * 83mm&lt;BR&gt;Product weight: ¡Ü 550g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7674F three-phase contactor (7674) has the characteristics of simple structure, large load design margin, and high reliability. Can be used in aviation, aerospace, weapons, ships and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG21029-2013&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7675F type contactor (7675)}) </title>
           <link>http://www.91way.com/info_en/29388.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:46</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7675F Contactor (7675)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 28Vd. c&lt;BR&gt;Product size: ¡Ñ 38 * 62&lt;BR&gt;Product weight: ¡Ü 250g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7675F contactor (7675) is a new type of normally open DC contactor that adopts a large number of new technologies, processes, strong load capacity, and high reliability. It can be applied in the fields of next-generation aviation, aerospace, weapons, electronics, and ships, and is an ideal component for circuit switching. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21026-2013.</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7678F type three-phase contactor (7678)} </title>
           <link>http://www.91way.com/info_en/29387.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:38</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7678F Three Phase Contactor (7678)&lt;BR&gt;Product specifications: 024Vd. c., 028Vd. c., 036Vd. c., 110Vd. c&lt;BR&gt;Load: 60Vd. c., 380Va. c., 115/200Va. c&lt;BR&gt;Product size: 107mm * 62mm * 83mm&lt;BR&gt;Product weight: ¡Ü 650g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. JQ-7678F three-phase contactor (7678) has three sets of bridge dynamic contact points, with a load current of 5-50A. 2. It complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21030-2013.</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7665F type three-phase contactor (7665)} </title>
           <link>http://www.91way.com/info_en/29386.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:29</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7665F Three Phase Contactor (7665)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 60Vd. c., 115/200Va. c., 220/380Va. c&lt;BR&gt;Product size: 111mm * 80mm * 100mm&lt;BR&gt;Product weight: ¡Ü 1350g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. JQ-7665F three-phase contactor (7665) has three sets of bridge type dynamic closing and breaking main contacts and three sets of bridge type dynamic closing and breaking auxiliary contacts, with a load current of 5-50A. 2. It complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/; RG21021-2013. Can be used interchangeably with 25810SBM.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7644F type three-phase contactor (7644)} </title>
           <link>http://www.91way.com/info_en/29384.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:20</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7644F Three phase Contactor (7644)&lt;BR&gt;Product specifications: 024Vd. c., 028Vd. c., 036Vd. c., 110Vd. c&lt;BR&gt;Load: 60Vd. c., 2 * 10 ^ 4 times&lt;BR&gt;Product size: 107mm * 62mm * 100mm&lt;BR&gt;Product weight: ¡Ü 700g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. The JQ-7644F three-phase contactor (7644) has three sets of bridge type dynamic closing and breaking contacts, which can be easily switched to three sets of bridge type conversion contacts, with a load current of 5-50A. 2. It complies with GJB2888-1997 &quot;General Specification for Power type Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20754-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7647M Three phase sealed contactor </title>
           <link>http://www.91way.com/info_en/29383.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:12</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7647M Three phase Sealed Contactor (7647)&lt;BR&gt;Product specifications: 024Vd. c., 036Vd. c., 048Vd. c., 110Vd. c., 220Vd. c&lt;BR&gt;Load: 28Vd. c&lt;BR&gt;Product size: 53.6mm * 53.6mm*&lt;BR&gt;Product weight: ¡Ü 500g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7647M three-phase sealed contactor (7647) is an AC input with three sets of bridge type dynamic closing main contacts and one set of conversion auxiliary contacts. It has the characteristics of compact structure and reliable operation, and can be used for switching high-voltage DC or three sets of AC load circuits in aviation, aerospace, and other electronic and electrical equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20757-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7681M type three-phase sealed contactor (7681)} </title>
           <link>http://www.91way.com/info_en/29382.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 20:00:03</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7681M Three phase Sealed Contactor (7681)&lt;BR&gt;Product specifications: 024Vd. c., 027Vd. c., 048Vd. c&lt;BR&gt;Load: 28Vd. c., 60Vd. c., 115Va. c., 380Va. c&lt;BR&gt;Product size: 53.6mm * 53.6mm * 47mm&lt;BR&gt;Product weight: ¡Ü 490g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;JQ-7681M three-phase sealed contactor (7681) is a high-power multi group sealed contactor mainly used for switching circuits in power control systems such as aviation and ships. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21023-2013.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7682M type three-phase sealed contactor (7682)} </title>
           <link>http://www.91way.com/info_en/29381.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:55</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7682M Three phase Sealed Contactor (7682)&lt;BR&gt;Product specifications: 024Vd. c., 036Vd. c., 048Vd. c.110Vd.c.220Vd. c&lt;BR&gt;Load: 28Vd. c., 60Vd. c., 115Va. c., 380Va. c&lt;BR&gt;Product size: 53.6mm * 53.6mm * 47mm&lt;BR&gt;Product weight: ¡Ü 500g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. JQ-7682M three-phase sealed contactor (7682) can be welded and sealed, AC input, with three sets of bridge conversion main contacts and one set of conversion auxiliary contacts. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21024-2013.</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7630F type three-phase contactor (7630)} </title>
           <link>http://www.91way.com/info_en/29378.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:47</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7630F Three Phase Contactor (7630)&lt;BR&gt;Product specifications: 012Vd. c., 024Vd. c., 027Vd. c&lt;BR&gt;Load: 115/200VA. C., 400Hz, 2.5 * 10 ^ 3&lt;BR&gt;Product size: 117mm * 67mm * 117mm&lt;BR&gt;Product weight: ¡Ü 1250g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7630F three-phase contactor (7630) is a three-phase AC contactor with the characteristics of simple structure, large load design margin, and high reliability. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20740-2011.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7643F type three-phase contactor (7643)} </title>
           <link>http://www.91way.com/info_en/29375.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:39</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7643F Three Phase Contactor (7643)&lt;BR&gt;Product specifications: 024Vd. c., 027Vd. c., 036Vd. c., 060Vd. c., 110Vd. c., 220Vd. c&lt;BR&gt;Load: 60Vd. c., 1 * 10 ^ 4 times&lt;BR&gt;Product size: 117mm * 69mm * 95mm&lt;BR&gt;Product weight: ¡Ü 1200g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;1. The coil voltage of JQ-7643F three-phase contactor (7643) can be DC or AC, with three sets of bridge dynamic contact points and a load current of 10-150A. 2. It complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20753-2011.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7662F type three-phase contactor (7662)} </title>
           <link>http://www.91way.com/info_en/29374.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:30</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7662F Three Phase Contactor (7662)&lt;BR&gt;Product specifications: 024Vd. c., 027Vd. c., 036Vd. c., 060Vd. c., 110Vd. c., 220Vd. c&lt;BR&gt;Load: 60Vd. c., 380Vd. c., 115/220Va. c&lt;BR&gt;Product size: 117mm * 69mm * 113mm&lt;BR&gt;Product weight: ¡Ü 1300g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The coil voltage of JQ-7662F three-phase contactor (7662) can be DC or AC, with three sets of bridge dynamic contact and three sets of bridge dynamic contact. It can also be easily switched to three sets of bridge conversion contact, with a load current of 10-150A. It complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Index&quot;. 3. Product enterprise standard number Q/RG20973-2012.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7645F type three-phase contactor (7645)} </title>
           <link>http://www.91way.com/info_en/29372.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:22</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7645F Three phase Contactor (7645)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 60Vd. c&lt;BR&gt;Product size: 123.5mm * 102mm * 92mm&lt;BR&gt;Product weight: 1550 &#177; 10% g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7645F three-phase contactor (7645) has the characteristics of multiple contact groups, high load, long service life, and strong environmental adaptability. It is used for switching circuits in equipment in aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21010-2013.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7679F type three-phase contactor (7679)} </title>
           <link>http://www.91way.com/info_en/29371.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:14</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7679F Three Phase Contactor (7679)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c., 115/200Va. c&lt;BR&gt;Product size: 144mm * 92mm * 118mm&lt;BR&gt;Product weight: ¡Ü 2400g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7679F three-phase contactor (7679) is a three-phase AC contactor with a load current of 200A. It has the characteristics of strong overload capacity and high reliability, and is widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21032-2013.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7677F type three-phase contactor (7677)} </title>
           <link>http://www.91way.com/info_en/29369.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:59:05</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7677F Three Phase Contactor (7677)&lt;BR&gt;Product specification: 027Vd. c&lt;BR&gt;Load: 28Vd. c., 115/200Va. c&lt;BR&gt;Product size: 144mm * 92mm * 138mm&lt;BR&gt;Product weight: ¡Ü 2700g&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7677F three-phase contactor (7677) is a three-phase contactor with a load current of 200A. It has the characteristics of strong overload capacity and high reliability, and is widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21031-2013.</description>
       </item>
       <item>
           <title>[AC contactor]JQ-7654F type three-phase contactor (7654)} </title>
           <link>http://www.91way.com/info_en/29357.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:57</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7654F Three Phase Contactor (7654)&lt;BR&gt;Product specification: 028Vd. c&lt;BR&gt;Load: 30Vd. c., 115Va. c., 200Va. c., 30Vd. c,&lt;BR&gt;Product size: 116mm * 80mm * 105mm&lt;BR&gt;Product weight: 1300 &#177; 3%&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;The JQ-7654F three-phase contactor (7654) has the characteristics of multiple contact groups, high load, long service life, and strong environmental adaptability. It is used for switching circuits in equipment in aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. Product enterprise standard number Q/RG20993-2013.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]100CX series AC contactor </title>
           <link>http://www.91way.com/info_en/27262.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:48</pubDate>
           <comments></comments>
           <description>&lt;P&gt;100CX series AC contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2016/201601/20160120183232787.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 400px; WIDTH: 275px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical performance of 100CX series AC contactor&quot; src=&quot;/upload2016/201601/20160120183232787.jpg&quot; width=275 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]100DX series AC contactor </title>
           <link>http://www.91way.com/info_en/27261.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;100DX series AC contactor&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2016/201601/20160120182915443.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 292px; WIDTH: 508px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical performance of 100DX series AC contactor&quot; src=&quot;/upload2016/201601/20160120182915443.jpg&quot; width=508 height=292&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CK3 series AC contactor </title>
           <link>http://www.91way.com/info_en/26210.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:31</pubDate>
           <comments></comments>
           <description>CK3ÏµÁÐ½»Á÷½Ó´¥Æ÷Ö÷ÒªÓÃÓÚ½»Á÷50Hz»ò60Hz¡¢¶î¶¨¹¤×÷µçÑ¹ÖÁ690V¼°¶î¶¨¹¤×÷µçÁ÷ÖÁ800AµÄµÍÑ¹ÅäµçÏµÍ³ÖÐ½ÓÍ¨ºÍ·Ö¶ÏµçÂ·£¬²¢¿ÉÓëCJR3ÈÈ¹ýÔØ¼ÌµçÆ÷»òCD1µç¶¯»ú±£»¤Æ÷»òCD4ÖÇÄÜÂí´ï±£»¤Æ÷×é³Éµç¶¯»úÆð¶¯Æ÷£¬ÒÔ±£»¤ÔËÐÐÖÐ¿ÉÄÜ·¢Éú¹ýÔØµÄµç¶¯»ú¡£²úÆ··ûºÏIEC60947-4-1¡¢GB 14048.4±ê×¼£¬²¢»ñµÃ¹ú¼ÒÇ¿ÖÆÐÔ²úÆ·ÈÏÖ¤¡°CCC¡±Ö¤Êé¡£ &lt;BR&gt;&lt;BR&gt;CK3ÏµÁÐ½»Á÷½Ó´¥Æ÷Ö÷Òª¼¼Êõ²ÎÊý±í &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;ÐÍºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-09F&lt;/P&gt;
&lt;P align=center&gt;CK3-09&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-12F&lt;/P&gt;
&lt;P align=center&gt;CK3-12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-18F&lt;/P&gt;
&lt;P align=center&gt;CK3-18&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-25F&lt;/P&gt;
&lt;P align=center&gt;CK3-25&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-32&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-40&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-65&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-80&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-09F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-09/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-12F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-12/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-18F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-18/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;CK3-25F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-25/G&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨¹¤×÷µçÑ¹Ue£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=13&gt;
&lt;P align=center&gt;AC220/230V£¬AC380/400V£¬AC660/690V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4&gt;
&lt;P align=center&gt;¶î¶¨¹¤×÷µçÁ÷&lt;/P&gt;
&lt;P align=center&gt;Ie£¨A£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;220/230V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;18&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;40&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;68&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;80&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;18&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;380/400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;18&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;40&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;65&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;80&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;18&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;660/690V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;5&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;15&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;19&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;26&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;38&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;44&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;5&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;AC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;¡Ü400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;60&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;65&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;20&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;25&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨¾øÔµµçÑ¹Ui(V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;690&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;690&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨³å»÷ÄÍÊÜµçÑ¹Uimp(V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;6000&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;8000&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;6000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;·É»¡¾àÀë£¨mm£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=13&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;»úÐµ&amp;nbsp;ÊÙÃü£¨Íò´Î£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;µçÊÙÃü£¨Íò´Î£©£¨AC-3 380/400V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;ÐÍºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-32/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-40/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-50/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-65/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-80/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;CK3-105&lt;/P&gt;
&lt;P align=center&gt;CK3-105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-125&lt;/P&gt;
&lt;P align=center&gt;CK3-125J&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-150&lt;/P&gt;
&lt;P align=center&gt;CK3-150J&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-180&lt;/P&gt;
&lt;P align=center&gt;CK3-180J&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CK3-220&lt;/P&gt;
&lt;P align=center&gt;CK3-220J&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;CK3-300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;CK3-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;CK3-600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;CK3-800&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨¹¤×÷µçÑ¹Ue£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;85%&quot; colSpan=14&gt;
&lt;P align=center&gt;AC220/230V£¬AC380/400V£¬AC660/690V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;4%&quot;&gt;
&lt;P align=center&gt;¶î¶¨¹¤×÷µçÁ÷Ie£¨A£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;4%&quot;&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;220/230V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;40&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;68&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;80&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;800&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;380/400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;32&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;40&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;65&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;80&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;800&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;660/690V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;19&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;26&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;38&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;64&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;72&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;103&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;230&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;360&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;630&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;P align=center&gt;AC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;¡Ü400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;65&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;260&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;260&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;350&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;450&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;660&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;800&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨¾øÔµµçÑ¹Ui(V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;85%&quot; colSpan=14&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;¶î¶¨³å»÷ÄÍÊÜµçÑ¹Uimp(V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;85%&quot; colSpan=14&gt;
&lt;P align=center&gt;8000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;·É»¡¾àÀë£¨mm£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;85%&quot; colSpan=14&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;»úÐµÊÙÃü£¨Íò´Î£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;1000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;250&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;µçÆøÊÙÃü£¨Íò´Î£©£¨AC-3 380/400V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;5. ¿ØÖÆµçÔ´µçÑ¹Us¶î¶¨Öµ¼°´úºÅ &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=161 colSpan=3&gt;
&lt;P align=center&gt;CK3-09F¡«25F&lt;/P&gt;
&lt;P align=center&gt;CK3-09¡«80&lt;/P&gt;
&lt;P align=center&gt;CK3-105J~220J&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=133 colSpan=2&gt;
&lt;P align=center&gt;CK3-09F/G¡«25F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-09/G¡«80/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=182 colSpan=3&gt;
&lt;P align=center&gt;CK3-105¡«800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181 colSpan=3&gt;
&lt;P align=center&gt;CK3-25/VS¡«400/VSÓÃ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=161 colSpan=3&gt;
&lt;P align=center&gt;½»Á÷²Ù×÷£¨AC£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=133 colSpan=2&gt;
&lt;P align=center&gt;Ö±Á÷²Ù×÷£¨DC£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=182 colSpan=3&gt;
&lt;P align=center&gt;½»Ö±Á÷Á½ÓÃ£¨AC/DC£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181 colSpan=3&gt;
&lt;P align=center&gt;½»Ö±Á÷Á½ÓÃ£¨AC/DC£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=76&gt;
&lt;P align=center&gt;µçÑ¹£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=85 colSpan=2&gt;
&lt;P align=center&gt;´úºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=83&gt;
&lt;P align=center&gt;µçÑ¹£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=51&gt;
&lt;P align=center&gt;´úºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147 colSpan=2&gt;
&lt;P align=center&gt;µçÑ¹£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=35&gt;
&lt;P align=center&gt;´úºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147 colSpan=2&gt;
&lt;P align=center&gt;µçÑ¹£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=34&gt;
&lt;P align=center&gt;´úºÅ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;50Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;AC&lt;/P&gt;
&lt;P align=center&gt;£¨50Hz/60Hz£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;AC&lt;/P&gt;
&lt;P align=center&gt;£¨50Hz/60Hz£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;24&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;E5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;24&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;E&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;24&lt;SUP&gt;1£©&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;24&lt;SUP&gt;1£©&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;E8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;36&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;I8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;36&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;I5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;F&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;36&lt;SUP&gt;1£©&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;I8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;F8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;F5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;H&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;48&lt;SUP&gt;1£©&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;48&lt;SUP&gt;1£©&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;F8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;H8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;H5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;M&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;H8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;127/132&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;U8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;220/230&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;N5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;220/230&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;M8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;220/230&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;M8&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;380/400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;45&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;380/400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;380/400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P align=center&gt;¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;48&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=657 colSpan=11&gt;
&lt;P&gt;×¢1£ºCK3-600¡¢800ÎÞ¸Ã¿ØÖÆµçÑ¹&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;6. CK3ÏµÁÐ½»Á÷½Ó´¥Æ÷¿ØÖÆÏßÈ¦ÌØÐÔ&amp;nbsp;&lt;BR&gt;½»Á÷²Ù×÷&amp;nbsp;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=63&gt;
&lt;P align=center&gt;ÐÍºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=2&gt;
&lt;P align=center&gt;¶¯×÷µçÑ¹·¶Î§&lt;/P&gt;
&lt;P align=center&gt;£¨50Hz¡¢60Hz£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126 colSpan=2&gt;
&lt;P align=center&gt;µç´ÅÌúÈÝÁ¿&lt;/P&gt;
&lt;P align=center&gt;£¨VA£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=49&gt;
&lt;P align=center&gt;¹¦ºÄ&lt;/P&gt;
&lt;P align=center&gt;£¨W£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;¶¯×÷Ê±¼ä&lt;/P&gt;
&lt;P align=center&gt;£¨ms£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;ÎüºÏ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;ÊÍ·Å&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;ÎüºÏÊ±&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;±£³ÖÊ±&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;ÏßÈ¦ON¡«Ö÷´¥Í·ON&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;ÏßÈ¦OFF¡«Ö÷´¥Í·OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-09F&lt;/P&gt;
&lt;P align=center&gt;CK3-09&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=18 width=56&gt;
&lt;P align=center&gt;0.85&lt;/P&gt;
&lt;P align=center&gt;¡«1.1Us&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=18 width=63&gt;
&lt;P align=center&gt;0.2&lt;/P&gt;
&lt;P align=center&gt;¡«0.75Us&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;2.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;9¡«20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;4¡«20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-12F&lt;/P&gt;
&lt;P align=center&gt;CK3-12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;2.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;9¡«20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;4¡«20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-18F&lt;/P&gt;
&lt;P align=center&gt;CK3-18&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;2.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;9¡«20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;4¡«20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-25F&lt;/P&gt;
&lt;P align=center&gt;CK3-25&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;2.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;9¡«20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;4¡«20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-32&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;120&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;10¡«17&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;6¡«13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-40&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;120&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;10¡«17&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;6¡«13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;120&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;10¡«17&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;6¡«13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-65&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;13.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;4.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;10¡«18&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;8¡«18&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-80&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;13.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;4.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;10¡«18&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;8¡«18&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;4.4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;39¡«45&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;27¡«33&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;130&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;4.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;30¡«36&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;130&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;4.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;3.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;30¡«36&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;195&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;5.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;4.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;38¡«44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;195&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;5.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;4.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;38¡«44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;310&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;6.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;5.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;43¡«49&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;41¡«47&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;310&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;6.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;5.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;43¡«49&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;41¡«47&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;460&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;7.8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;69¡«75&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;56¡«62&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;CK3-800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;460&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;7.8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=147&gt;
&lt;P align=center&gt;69¡«75&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=153&gt;
&lt;P align=center&gt;56¡«62&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Ö±Á÷²Ù×÷&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=77&gt;
&lt;P align=center&gt;ÐÍºÅ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=2&gt;
&lt;P align=center&gt;¶¯×÷µçÑ¹·¶Î§&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126 colSpan=2&gt;
&lt;P align=center&gt;µç´ÅÌúÈÝÁ¿&lt;/P&gt;
&lt;P align=center&gt;£¨W£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;¹¦ºÄ&lt;/P&gt;
&lt;P align=center&gt;(W)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=258 colSpan=2&gt;
&lt;P align=center&gt;¶¯×÷Ê±¼ä&lt;/P&gt;
&lt;P align=center&gt;£¨ms£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;ÎüºÏ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;ÊÍ·Å&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;ÎüºÏÊ±&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;±£³ÖÊ±&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;±£³ÖÊ±&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;ÏßÈ¦ON¡«Ö÷´¥Í·ON&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;ÏßÈ¦OFF¡«Ö÷´¥Í·OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-09F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-09/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=18 width=56&gt;
&lt;P align=center&gt;0.85&lt;/P&gt;
&lt;P align=center&gt;¡«1.1Us&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=18 width=63&gt;
&lt;P align=center&gt;0.1&lt;/P&gt;
&lt;P align=center&gt;¡«&lt;/P&gt;
&lt;P align=center&gt;0.75Us&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;43¡«47&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;10¡«24&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-12F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-12/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;43¡«47&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;10¡«24&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-18F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-18/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;43¡«47&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;10¡«24&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-25F/G&lt;/P&gt;
&lt;P align=center&gt;CK3-25/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;43¡«47&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;10¡«24&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-32/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;40¡«50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;8¡«17&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-40/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;40¡«50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;8¡«17&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-50/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;9&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;40¡«50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;8¡«17&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-65/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;60¡«70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;14¡«21&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-80/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;60¡«70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;14¡«21&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-105&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;85&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;35¡«41&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;26¡«32&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;145&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;2.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;28¡«34&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;27¡«33&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;145&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;2.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;28¡«34&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;27¡«33&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-180&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;225&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;3.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;33¡«39&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-220&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;225&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;3.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;33¡«39&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;31¡«37&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-300&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;325&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;3.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;38¡«44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;41¡«47&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;325&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;3.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;38¡«44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;41¡«47&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;490&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;5.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;64¡«70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;52¡«57&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CK3-800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;490&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;5.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;P align=center&gt;64¡«70&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;52¡«57&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CK3ÏµÁÐ½»Á÷½Ó´¥Æ÷&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX28 series rotary AC contactor </title>
           <link>http://www.91way.com/info_en/24244.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:22</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212184028262.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 441px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CJX28 series rotary AC contactor external dimensions&quot; src=&quot;/upload2013/201312/20131212184028262.jpg&quot; width=680 height=441&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212184038766.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 322px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CJX28 series rotary AC contactor&quot; src=&quot;/upload2013/201312/20131212184038766.jpg&quot; width=680 height=322&gt;&lt;/A&gt;&lt;BR&gt;CJX28 series rotary AC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX35 series direct acting AC contactor </title>
           <link>http://www.91way.com/info_en/24231.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:13</pubDate>
           <comments></comments>
           <description>CJX35 series direct acting AC contactor&lt;BR&gt;&lt;BR&gt;1. CJX35- AC contactor enterprise model&lt;BR&gt;2. Basic specification code, represented by the rated working current under the usage category of 380V and AC-3&lt;BR&gt;3. Number of main contacts&lt;BR&gt;4. The number of auxiliary contacts, with one digit indicating the number of normally closed contacts and ten digits indicating the number of normally open contacts&lt;BR&gt;5. It is a tropical product code, represented by TH&lt;BR&gt;&lt;BR&gt;Product Structure Features:&lt;BR&gt;Simple and compact structure, unique and innovative, modular functionality, and modular assembly.&lt;BR&gt;The coil is encapsulated in plastic, with advanced technology, beautiful appearance, good insulation strength, and high mechanical strength.&lt;BR&gt;CJX35-09-95 has strong platform performance, and accessories such as auxiliary contact groups, air delay heads, mechanical interlocks, etc. can be installed on all five surfaces except for the bottom surface.&lt;BR&gt;The CJX35-115-780 cable and static iron core form a drawer, which can be easily installed or removed by pressing a button for easy maintenance.&lt;BR&gt;The arc extinguishing hood is made of high-strength plastic compression, with high mechanical strength and good arc extinguishing performance. It is also fixed by a locking rod rotating compression spring, which is convenient and reliable.&lt;BR&gt;The CJX35-40-95 contactor has a large number of auxiliary contacts and is easy to replace. It comes with a normally open and normally closed auxiliary contact and can also be equipped with an auxiliary contact group. There are a total of 6 pairs of auxiliary contact groups available for selection. CJX35-115-780 contactor can be equipped with two auxiliary contact groups&lt;BR&gt;8 pairs of auxiliary contacts. The installation of the auxiliary contact group does not require screws to fix. Just push along the guide rail and hear a &quot;click&quot; sound. If an air delay head is needed, it can be directly used to replace the auxiliary contact group.&lt;BR&gt;The contactor has a significant energy-saving effect. CJX35-400-780 is an AC input DC control.&lt;BR&gt;The mechanical interlocking of the contactor is simple and reliable. It can horizontally interlock two contactors. CJX35-115-630 can also achieve vertical interlocking of two contactors and vertical interlocking of three contactors.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJ35 series AC contactor </title>
           <link>http://www.91way.com/info_en/24230.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:58:04</pubDate>
           <comments></comments>
           <description>The CJ35 series contactor is a direct acting AC contactor.&lt;BR&gt;Mainly used in power systems with AC 50Hz (or 60Hz), rated operating voltage up to 1000V, and rated operating current up to 780A, for remote connection, disconnection of circuits, and starting, stopping, reverse, and reverse connection of brake motors.&lt;BR&gt;&lt;BR&gt;This series of contactors has more than 20 specifications, including CJ35-09, 12, 18, 25, 32, 40, 50, 65, 80, 95, 115, 150, 185, 225, 265, 330, 400, 500, 630, 780, etc. It can replace the corresponding specifications of domestic CJ10, CJ12, CJ20 series, as well as imported LC1-D, LC1-F, 3TB, B series.&lt;BR&gt;&lt;BR&gt;The CJ35-115-780 contactor can also be used as a DC contactor.&lt;BR&gt;This series of contactors complies with the following international and domestic standards;&lt;BR&gt;IEC60947-1£¨1999£©¡¢IEC947-4-1&lt;BR&gt;GB/T14048.1-2000¡¢GB14048.4-93&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;Action performance:&lt;BR&gt;Pull in voltage 85% -110% Us;&lt;BR&gt;Release voltage AC coil 20% -75% Us, direct charging coil 10% -75% Us.&lt;BR&gt;Control voltage of coil&lt;BR&gt;CJ35-09-95 DC 127, 220, 380V&lt;BR&gt;CJ35-115-780 DC 127, 220, 380V; DC 110, 220V&lt;BR&gt;*It can also be used for coils of any other voltage.&lt;BR&gt;The adjacent auxiliary contacts of the auxiliary contact group are electrically separable, and their models and combinations are shown in the table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;Auxiliary contact group model&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D11&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D20&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D22&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D13&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D31&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;LA1-D40&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=center&gt;LA1-D04&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;Number of normally open contacts&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;one&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;one&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;three&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;four&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=center&gt;0&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;Number of normally closed contacts&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;one&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;0&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;three&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;one&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;0&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=center&gt;four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: LA1-F22 is specifically designed for CJ35-115 and above specifications, with a wiring terminal sequence number of 1-4. The sequence number of auxiliary contact groups for other models is 5-6 or 5-8.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;Product model&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;Rated insulation voltage V&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;Operating frequency times/h&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;Electric lifespan of 10000 times&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;Mechanical lifespan of 10000 cycles&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;Working power of coil W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-09&lt;/TD&gt;
&lt;TD rowSpan=10 width=&quot;16%&quot; align=center&gt;660V&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot; align=center&gt;one thousand and two hundred&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot; align=center&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-12&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-18&lt;/TD&gt;
&lt;TD rowSpan=8 width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-25&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eleven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-32&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eleven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-40&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-50&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-65&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;eight hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-80&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-95&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-115&lt;/TD&gt;
&lt;TD rowSpan=10 width=&quot;16%&quot; align=center&gt;1000V&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot; align=center&gt;one thousand and two hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;twenty-four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-150&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;forty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-185&lt;/TD&gt;
&lt;TD rowSpan=8 width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;twenty-four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-225&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;fifty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-265&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;forty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-330&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;thirteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-400&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-500&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;twenty-four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-630&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;twenty-six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot; align=center&gt;CJ35-780&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;sixty&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;six hundred&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; align=center&gt;twenty-eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Product Structure Features&lt;BR&gt;Simple and compact structure, unique and innovative, modular functionality, and modular assembly;&lt;BR&gt;The coil is encapsulated in plastic, with advanced technology, beautiful appearance, high insulation strength, and high mechanical strength;&lt;BR&gt;CJ35-09-95 has strong versatility, and accessories such as auxiliary contact groups, air delay heads, and mechanism interlocks can be installed on all five sides except for the bottom surface;&lt;BR&gt;The arc extinguishing hood is made of high-strength plastic compression, with high mechanical strength and good arc extinguishing performance. It is also fixed by a locking rod rotating compression spring, which is convenient and reliable.&lt;BR&gt;The CJ35-40-95 contactor has a large number of auxiliary contacts and is easy to replace. It comes with one normally open and one normally closed auxiliary contact, and can also be equipped with an auxiliary contact group. There are a total of six pairs of auxiliary contact groups available for selection. The CJ35-115-780 contactor coil is equipped with a dedicated auxiliary contact for self-locking or DC control conversion, and can also be equipped with two sets of auxiliary contacts, totaling 8 pairs of auxiliary contacts. The installation of the auxiliary contact group does not require screws to fix, just push along the guide rail and hear a &quot;click&quot; sound. If an air delay head is needed, it can be directly used to replace the auxiliary contact group;&lt;BR&gt;&lt;BR&gt;The contactor has a significant energy-saving effect, and CJ35-400-780 is controlled by AC input direct charging;&lt;BR&gt;The interlocking mechanism of the contactor is simple and reliable, and can interlock two units horizontally; CJ35-115-630 can also achieve two vertical interlocks and three vertical interlocks.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJ156 series AC contactor </title>
           <link>http://www.91way.com/info_en/24229.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:56</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131209144129241.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1190px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CJ156 series AC contactors&quot; src=&quot;/upload2013/201312/20131209144129241.jpg&quot; width=600 height=1190&gt;&lt;/A&gt;&lt;BR&gt;CJ156 series AC contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX28-2500K/3 AC contactor </title>
           <link>http://www.91way.com/info_en/24224.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:48</pubDate>
           <comments></comments>
           <description>CJX28-2500K/3 AC contactor&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-FN series mechanical interlocking AC contactor </title>
           <link>http://www.91way.com/info_en/23915.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201309/20130923193510989.gif&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/upload2013/201309/20130923193510989.gif&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CJX2-FN series mechanical interlocking AC contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]SRMC12-115~630 AC contactor mechanical interlocking mechanism </title>
           <link>http://www.91way.com/info_en/23498.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:31</pubDate>
           <comments></comments>
           <description>The mechanical interlocking mechanism of SRMC12-115~630 AC contactors can be combined with SRMC12 series AC contactors, mainly used in the forward and reverse rotation and energy consumption braking AC lines of electric motors to prevent line short circuit faults caused by misoperation. &amp;nbsp;&lt;BR&gt;This institution is applicable to reversible contactors consisting of SRMC12 AC contactors installed vertically and horizontally. &amp;nbsp;&lt;BR&gt;This organization complies with standards such as IEC60947-1-4 and GB14048.4.&lt;BR&gt;&lt;BR&gt;Normal working and installation conditions&lt;BR&gt;1. The ambient air temperature ranges from -5 ¡æ to+40 ¡æ. The average value within 24 hours shall not exceed+35 ¡æ;&lt;BR&gt;2. Altitude: not exceeding 2000m&lt;BR&gt;3. Atmospheric conditions: At+40 ¡æ, the relative humidity of the air does not exceed 50%; At lower temperatures, there can be higher relative humidity, with an average minimum temperature of no more than+25 ¡æ in the wettest month and an average maximum relative humidity of no more than 90% in that month, taking into account condensation that may occur on the product due to temperature changes;&lt;BR&gt;4. Installation conditions: The inclination between the installation surface and the vertical surface shall not exceed 5 &#176;;&lt;BR&gt;5. Impact vibration: The product should be installed and used in a place without significant shaking, impact, and vibration.&lt;BR&gt;&lt;BR&gt;Main parameters and technical performance of SRMC12-115~630 AC contactor mechanical interlocking mechanism&lt;BR&gt;&lt;BR&gt;When the mechanical interlocking mechanism and two SRMC12 contactors form a reversible contactor, when the moving and stationary contacts of one contactor just make contact, push the other contactor to make the two interlocking components collide. At this time, the gap between the moving and stationary contacts is shown in the table below.&lt;BR&gt;2. Mechanical lifespan&lt;BR&gt;The mechanical lifespan of mechanical interlocking is 3 million cycles for SRMJLC-FF and SRMJLS-FF, and 2 million cycles for the rest&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;DIV align=center&gt;Gap mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115N~150N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ý5.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-185N~225N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ý5.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-265N~330N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ý6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-400N~500N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ý6.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-630N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ý7&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[AC contactor]SRMC11 series AC contactor </title>
           <link>http://www.91way.com/info_en/23497.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:23</pubDate>
           <comments></comments>
           <description>SRMC11 series AC contactors (hereinafter referred to as contactors) are mainly used for connecting and disconnecting circuits in power systems with AC 50Hz (or 60Hz), rated working voltage up to 1000V, and rated working current up to 75A. And combined with appropriate thermal relays or electronic protection devices to form a motor starter to protect circuits that may experience overload. &amp;nbsp;&lt;BR&gt;The contactor complies with IEC60947-4-1 and GB14048.4 standards.&lt;BR&gt;&lt;BR&gt;Normal working and installation conditions&lt;BR&gt;&lt;BR&gt;1. The ambient air temperature ranges from -5 ¡æ to+40 ¡æ. The average value within 24 hours shall not exceed+35 ¡æ;&lt;BR&gt;2. Altitude: not exceeding 2000m&lt;BR&gt;3. Atmospheric conditions: At+40 ¡æ, the relative humidity of the air does not exceed 50%; At lower temperatures, there can be higher relative humidity, with an average minimum temperature of no more than+25 ¡æ in the wettest month and an average maximum relative humidity of no more than 90% in that month, taking into account condensation that may occur on the product due to temperature changes;&lt;BR&gt;4. Installation conditions: The inclination between the installation surface and the vertical surface shall not exceed 5 &#176;;&lt;BR&gt;5. Impact vibration: The product should be installed and used in a place without significant shaking, impact, and vibration.&lt;BR&gt;&lt;BR&gt;Main parameters and technical performance of SRMC11 series AC contactors&lt;BR&gt;&lt;BR&gt;1. Main specifications of contactors&lt;BR&gt;Divided by current level: 9A, 12A, 16A, 25A, 30A, 40A, 50A, 65A, 75A.&lt;BR&gt;According to the rated control power supply Us of the contactor coil, it is divided into AC 50Hz: 380V, 220V, 127V, 36V&lt;BR&gt;2. Main technical parameters of the contactor&lt;BR&gt;Action characteristics: suction voltage is 85% -110% Us, release voltage is 20% -75% Us;&lt;BR&gt;The contact types and basic parameters of the auxiliary contacts and auxiliary contact modules of the contactor are shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;product&lt;BR&gt;Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Agreed to send&lt;BR&gt;Current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation&lt;BR&gt;Voltage A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated working voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated working current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated control capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Number of contact types&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;communication&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;direct current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;communication&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;direct current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;communication&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;direct current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;Dynamic combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Dynamic interruption&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-09~25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;six hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;three hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point two six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point one four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;AC-15&lt;BR&gt;100VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;DC-13&lt;BR&gt;30W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;CA7&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;CAL7-11&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point four five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3. The main parameters and technical performance indicators of the contactor are shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=24 rowSpan=2 width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Contactor model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Rated Absolute&lt;BR&gt;Edge voltage&lt;BR&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Agreed to send&lt;BR&gt;current&lt;BR&gt;£Á&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Under the AC-3 usage category, it is possible to&lt;BR&gt;Controlling the Three Squirrel Cage Motor&lt;BR&gt;Maximum power kW&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;
&lt;P align=center&gt;Number of operating cycles per hour&lt;BR&gt;Times/h&lt;BR&gt;£¨AC-3£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;AC-3&lt;BR&gt;electrical life&lt;BR&gt;(Ten thousand times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;machine&lt;BR&gt;lifespan&lt;BR&gt;(Ten thousand times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Coil power&lt;BR&gt;Power/operation&lt;BR&gt;VA/VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;Selected fuses (SCPD)&lt;BR&gt;model&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;660V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;1000V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-09&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;six hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=9&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one thousand and two hundred&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;60/9&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-12&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-16&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-32&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;85/10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-50&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-63&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one thousand and two hundred&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;190/15.2&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-65&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC11-75&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT16-160&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;&lt;BR&gt;1. The contactor is a direct acting structure, with the contact arc extinguishing system located at the upper part and the magnetic system located at the lower part. The contacts are double break points and made of silver alloy. 25A and below body with movable or movable auxiliary contacts, 30-75A contactor body without auxiliary contacts, 40-75A side can be equipped with CAL7-11 auxiliary contacts, CA7 auxiliary contacts can be added to the top of the entire series of products, and mechanical interlocking can be installed on the side.&lt;BR&gt;SRMC11-09-30 can be installed on 35mm standard card rails, while SRMC11-40-75 can be installed on 35mm or 75mm standard card rails.&lt;BR&gt;3. Two SRMC11 AC contactors can form a reversible contactor.&lt;BR&gt;4. Four pole contactors can be derived, among which SRMC11-09-25 has the same external dimensions as three poles.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]SRMC12 series AC contactor </title>
           <link>http://www.91way.com/info_en/23496.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:14</pubDate>
           <comments></comments>
           <description>SRMC12 series AC contactors (hereinafter referred to as contactors) are mainly used in circuits with AC 50Hz or 60Hz, rated working voltage up to 1000V, and rated working current up to 630A for remote connection and disconnection of circuits. They can also be combined with appropriate thermal overload relays to form electromagnetic starters to protect circuits that may experience operational overload. &amp;nbsp;&lt;BR&gt;The product complies with IEC60947-4-1 and GB14048.4 standards.&lt;BR&gt;&lt;BR&gt;Normal working and installation conditions of SRMC12 series AC contactors&lt;BR&gt;&lt;BR&gt;1. The ambient air temperature ranges from -5 ¡æ to+40 ¡æ. The average value within 24 hours shall not exceed+35 ¡æ;&lt;BR&gt;2. Altitude: not exceeding 2000m&lt;BR&gt;3. Atmospheric conditions: At+40 ¡æ, the relative humidity of the air does not exceed 50%; At lower temperatures, there can be higher relative humidity, with an average minimum temperature of no more than+25 ¡æ in the wettest month and an average maximum relative humidity of no more than 90% in that month, taking into account condensation that may occur on the product due to temperature changes;&lt;BR&gt;4. Installation conditions: The inclination between the installation surface and the vertical surface shall not exceed 5 &#176;;&lt;BR&gt;5. Impact vibration: The product should be installed and used in a place without significant shaking, impact, and vibration.&lt;BR&gt;&lt;BR&gt;Main parameters and technical performance of SRMC12 series AC contactors&lt;BR&gt;&lt;BR&gt;1. Main specifications of contactors&lt;BR&gt;Divided by current level: 115A, 150A, 185A, 225A, 265A, 330A, 400A, 500A, 630A. &amp;nbsp;&lt;BR&gt;According to the rated control power supply voltage Us of the contactor coil, it is divided into AC 50Hz, 110V, 127V, 220V, and 380V.&lt;BR&gt;&lt;BR&gt;The main technical parameters of the contactor are shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;contactor&lt;BR&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;Promise&lt;BR&gt;fever&lt;BR&gt;current&lt;BR&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Rated working current A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Controllable three-phase squirrel cage type&lt;BR&gt;Maximum power of the electric motor (kW)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;per hour&lt;BR&gt;operation&lt;BR&gt;cyclic number&lt;BR&gt;Times/h&lt;BR&gt;£¨AC-3£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;AC-3&lt;BR&gt;Electric lifespan&lt;BR&gt;fate&lt;BR&gt;Ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;machine&lt;BR&gt;lifespan&lt;BR&gt;Ten thousand times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;Selected fuses (SCPD)&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;AC-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;AC-4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;AC-3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=44&gt;
&lt;DIV align=center&gt;380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;660V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;1000V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;660V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;1000V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;Current A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and thirty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and thirty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and thirty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RT-16-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3. The model specifications and parameters of the auxiliary hoe group are shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=24 colSpan=2&gt;
&lt;DIV align=center&gt;serial number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-11&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;F4-31&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-22&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-13&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;F4-04&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;quantity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=24 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Dynamic combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dynamic interruption&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4. Action characteristics&lt;BR&gt;The suction voltage is 85% -110% Us&lt;BR&gt;The release voltage for ordinary products is 20% -75% Us, for energy-saving products it is 10% -75% Us, and for energy-saving products it is 10% -75% Us&lt;BR&gt;&lt;BR&gt;5. The main specification codes of the coil are shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; LINE-HEIGHT: 20px&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;Contactor model&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Control voltage V&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Power VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;start&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;maintain&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Line diagram code&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-115¡¢150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FF110&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FF127&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FF220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FF380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=7&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-185¡¢225&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FG110&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FG127&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FG220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FG380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine hundred and sixty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-265&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FH110&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FH127&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FH220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FH380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-330&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FI110J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FI127J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FI220J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FI380J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FJ110J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FJ127J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FJ220J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FJ380J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FK110J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FK127J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FK220J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FK380J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SRMC12-630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FL110J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FL127J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FL220J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FL380J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]NCH8 Household AC contactor </title>
           <link>http://www.91way.com/info_en/22787.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:57:06</pubDate>
           <comments></comments>
           <description>The NCH8 series household AC contactor (hereinafter referred to as the contactor) is mainly suitable for controlling low inductance loads of household appliances and similar purposes in circuits with AC 50Hz (or 60Hz), rated working voltage up to 400V, and rated working current up to 63A; It can also be used to control the load of household electric motors, and the control power should be correspondingly reduced.&lt;BR&gt;&lt;BR&gt;NCH8 household AC contactor is applied in homes, hotels, apartments and other places to achieve automation functions, and is used in large-scale production of household appliances. Compliant with standards: GB 17885, IEC 61095&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CL series contactors </title>
           <link>http://www.91way.com/info_en/20154.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:57</pubDate>
           <comments></comments>
           <description>CL series contactor&lt;BR&gt;&lt;BR&gt;CL00A300T¡¢CL00A300TD¡¢CL00A300TJ¡¢CL00A300TN¡¢CL00A300TR¡¢CL00A300TU¡¢CL00A300TX¡¢CL00A301T¡¢CL00A301TD¡¢CL00A301TJ¡¢CL00A301TN¡¢CL00A301TR¡¢CL00A301TU¡¢CL00A301TX¡¢CL00A310T¡¢CL00A310TD¡¢CL00A310TJ¡¢CL00A310TN¡¢CL00A310TR¡¢CL00A310TU¡¢CL00A310TX¡£&lt;BR&gt;CL01A300T¡¢CL01A300TD¡¢CL01A300TJ¡¢CL01A300TN¡¢CL01A300TR¡¢CL01A300TU¡¢CL01A300TX¡¢CL01A301T¡¢CL01A301TD¡¢CL01A301TJ¡¢CL01A301TN¡¢CL01A301TR¡¢CL01A301TU¡¢CL01A301TX¡¢CL01A310T¡¢CL01A310TD¡¢CL01A310TJ¡¢CL01A310TN¡¢CL01A310TR¡¢CL01A310TU¡¢CL01A310TX&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]ABB-ESB series building contactors </title>
           <link>http://www.91way.com/info_en/20121.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:49</pubDate>
           <comments></comments>
           <description>ABB's ESB building contactors are suitable for achieving automatic control of building equipment, especially for switching and controlling lighting, heating, ventilation, water pumps, heat pumps, and other equipment. It can be installed on a 35mm guide rail.&lt;BR&gt;&lt;BR&gt;Features:&lt;BR&gt;Silent electromagnetic operating mechanism. Switch position indication. Contains surge voltage absorber. Additional auxiliary contacts. Enhance the capacity and lifespan of the switch. Open large-scale wiring method.&lt;BR&gt;Structure:&lt;BR&gt;ESB24¡¢ 40 and 63 are equipped with diode rectifiers and are AC/DC operating systems, with no noise at all when closed. It is also equipped with a varistor to protect the coil from surge voltages up to 5KV, thus suppressing electromagnetic system interference voltage. And the contactor can be combined with PLC for use. The contacts inside the contactor are the main contacts and can also be used as auxiliary contacts, which are not limited to switch control signals. The half modulus wide bipolar auxiliary contact EH04 can be installed on ESB24, 40, and 63.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-8011 AC contactor </title>
           <link>http://www.91way.com/info_en/19095.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:41</pubDate>
           <comments></comments>
           <description>CJX2-8011 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-5011 AC contactor </title>
           <link>http://www.91way.com/info_en/19094.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:32</pubDate>
           <comments></comments>
           <description>CJX2-5011 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-3201 AC contactor </title>
           <link>http://www.91way.com/info_en/19093.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:24</pubDate>
           <comments></comments>
           <description>CJX2-3201 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-2501 AC contactor </title>
           <link>http://www.91way.com/info_en/19092.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:15</pubDate>
           <comments></comments>
           <description>CJX2-2501 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-1801 AC contactor </title>
           <link>http://www.91way.com/info_en/19091.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:56:07</pubDate>
           <comments></comments>
           <description>CJX2-1801 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]CJX2-1201 AC contactor </title>
           <link>http://www.91way.com/info_en/19090.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:55:59</pubDate>
           <comments></comments>
           <description>CJX2-1201 AC contactor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[AC contactor]GC3 series reversible AC contactor </title>
           <link>http://www.91way.com/info_en/18245.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:55:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GC3 series reversible AC contactor is mainly suitable for circuits with rated insulation voltage of 690V at AC 50Hz (or 60Hz), rated working voltage of 380V under AC-3 usage category, and rated working current up to 500A level. It is used to control reversible operation or reverse braking of electric motors, and can prevent phase to phase short circuit during commutation of the motor. It is safer and more reliable than only electrical interlocking, and is combined with GR1 thermal relay of corresponding specifications to protect possible overload circuits. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216140728314.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 601px; WIDTH: 650px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of GC3 series reversible AC contactor&quot; src=&quot;/upload2012/201202/20120216140728314.jpg&quot; width=650 height=601&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]GC2 series switching capacitor contactor </title>
           <link>http://www.91way.com/info_en/18244.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:55:42</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GC2 series switching capacitor contactor is mainly suitable for connecting and disconnecting power capacitors in compensation circuits with AC 50Hz and rated voltage of 380V to adjust the power factor of the power system. The contactor has the ability to suppress inrush current, so that the peak inrush current when connected is not greater than 20 times the rated working current. The applicable working conditions are the same as those of the GC1 series contactor.&lt;BR&gt;&lt;BR&gt;The GC2 series switching capacitor contactor is derived from the B-series AC contactor product, so its technical performance indicators are the same as those of B-series AC contactors with the same current specifications, except for mechanical and electrical life. This product consists of two sets of special auxiliary contacts and current limiting and forced discharge resistors assembled on both sides of the contactor. When the capacitor is put into operation, the auxiliary contacts of the series current limiting resistor are first closed, limiting the charging surge current of the capacitor to within 20 times the rated current Ie of the capacitor. Then, the main contact of the contactor is closed, limiting the second surge current to within 20 times. This structure requires a combination of contactors and current limiting reactors, which were previously used, and eliminates a set of contactors and reactors, resulting in significant cost savings. This type of contactor overcomes the disadvantage of CJ16 and CJ19 series contactors having no discharge resistance, which causes the residual voltage of the capacitor to be too high when the capacitor is put back into operation for the second time, resulting in the burning of the current limiting resistor of the contactor and even the welding of the contact. A forced discharge resistor is installed. When the contactor cuts the running capacitor off the grid, the normally closed contact of the special auxiliary contact of the contactor is closed, and the capacitor is short circuited and discharged through the forced discharge resistor to ensure that the residual voltage of the capacitor is not greater than 50V when it is put back into operation for the second time, meeting the technical requirements and avoiding the burning of the current limiting resistor and the welding of the main contact of the contactor. The GC2 series of switching capacitor contactors with 5 current specifications features advanced and innovative design, high operational reliability, and high technical and economic indicators. They are indispensable components in compensating capacitor cabinets. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical parameters of GC2 series switching capacitor contactor&lt;BR&gt;&lt;BR&gt;The contactor can be equipped with CA7-10 or CA7-01 auxiliary contact sets, and the required quantity will be ordered separately (GC2-32, 43 up to 4, GC2-63-85 up to 6). GC2-32 type body comes with a set of normally open auxiliary contacts, while other specifications do not come with auxiliary contacts.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216140523342.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 173px; WIDTH: 650px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of GC2 series switching capacitor contactor&quot; src=&quot;/upload2012/201202/20120216140523342.jpg&quot; width=650 height=173&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]GC1 series AC contactor </title>
           <link>http://www.91way.com/info_en/18243.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:55:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GC1 series AC contactor is mainly suitable for power systems with AC frequency of 50Hz, rated voltage up to 660V, and current up to 800A. It is used for remote connection and disconnection of circuits, as well as frequent starting and control of AC motors. It can be combined with GR1 series thermal relays or electronic protection devices to form a motor starter to protect circuits that may experience overload. It is widely used in light industry, metallurgy, coal mining, machinery, lifting, railway and other fields. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;meet the standard&lt;BR&gt;GB 14048.1 Low voltage switchgear and control gear Part 1 General principles (IEC 60947-1)&lt;BR&gt;GB 14048.4 Low voltage switchgear and control equipment - Electromechanical contactors and motor starters (IEC60947-4-1)&lt;BR&gt;GB 14048.5 Low voltage switchgear and control gear Part 5-1 Control circuit appliances and switching elements Electrical control circuit appliances (IEC 60947-5-1)&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216135943162.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1443px; WIDTH: 650px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of GC1 series AC contactor&quot; src=&quot;/upload2012/201202/20120216135943162.jpg&quot; width=650 height=1443&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[AC contactor]SC-E series AC contactor </title>
           <link>http://www.91way.com/info_en/17528.html</link>
           <author></author>
           <guid></guid>
           <category>AC contactor</category>
           <pubDate>2026-6-9 19:55:25</pubDate>
           <comments></comments>
           <description>Technical parameter table of SC-E series AC contactor&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 685px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=685 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=40&gt;
&lt;P align=center&gt;SC-E02&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=center&gt;SC-E03&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=21&gt;
&lt;P align=center&gt;SC-E04&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=center&gt;SC-E05&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;P align=center&gt;SC-E1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=29&gt;
&lt;P align=center&gt;SC-E2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;SC-E2S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=center&gt;SC-E3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38&gt;
&lt;P align=center&gt;SC-E4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;SC-E02/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=center&gt;SC-E03/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=center&gt;SC-E04/G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;SC-E05/G&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=4&gt;
&lt;P align=center&gt;zero point three three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=109 colSpan=3&gt;
&lt;P align=center&gt;0.58&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86 colSpan=2&gt;
&lt;P align=center&gt;one point zero five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=243 colSpan=4&gt;
&lt;P align=center&gt;zero point five nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Overall dimensions&lt;BR&gt;(Width x Height x Length) (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=4&gt;
&lt;P align=center&gt;43&#215;80&#215;81&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=109 colSpan=3&gt;
&lt;P align=center&gt;54&#215;90&#215;96&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86 colSpan=2&gt;
&lt;P align=center&gt;67&#215;112&#215;111&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=243 colSpan=4&gt;
&lt;P align=center&gt;43&#215;80&#215;108&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Rated working voltage Ue (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;AC220/230V£¬AC380/400V£¬AC660/690V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=14&gt;
&lt;P align=center&gt;Rated working current&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=60&gt;
&lt;P align=center&gt;AC-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;220/230V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;32&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;sixty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;380/400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;sixty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;660/690V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;thirty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;forty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=left&gt;nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;AC-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;¡Ü400V¡¡&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;sixty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=left&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Rated insulation voltage Ui (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=4&gt;
&lt;P align=center&gt;six hundred and ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=195 colSpan=5&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=243 colSpan=4&gt;
&lt;P align=center&gt;690&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Rated impulse withstand voltage Uimp (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119 colSpan=4&gt;
&lt;P align=center&gt;six thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=195 colSpan=5&gt;
&lt;P align=center&gt;eight thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=243 colSpan=4&gt;
&lt;P align=center&gt;six thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Agreed heating current Ith (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;sixty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;20&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=60 colSpan=2&gt;
&lt;P align=center&gt;Rated control power Pe&lt;BR&gt;AC-3(KW)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;220/230V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;eighteen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;380/400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;eighteen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;660/690V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;thirty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=60 colSpan=2&gt;
&lt;P align=center&gt;lifespan&lt;BR&gt;&lt;BR&gt;(Ten thousand times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;machine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;Electrical (AC-3 380/400V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Operating frequency (times/hour) (AC-3)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=3&gt;
&lt;P align=center&gt;one thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=245 colSpan=6&gt;
&lt;P align=center&gt;1200&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=157 colSpan=3&gt;
&lt;P align=center&gt;one thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=50&gt;
&lt;P align=center&gt;one thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Flying arc distance (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;vibration-resistant&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;10¡«55Hz&amp;nbsp; 15m/s2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;impact-resistant&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;50m/s2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Protection level&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;IP2X&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Reversible type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;There is this model available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;DC operation type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=451 colSpan=9&gt;
&lt;P align=center&gt;No such model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=209 colSpan=4&gt;
&lt;P align=center&gt;There is this model available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Mechanical locking type&lt;BR&gt;(For the sale of pre ordered products)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;There is this model available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;delayed release&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 colSpan=9&gt;
&lt;P align=center&gt;No such model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=243 colSpan=4&gt;
&lt;P align=center&gt;There is this model available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=128 colSpan=3&gt;
&lt;P align=center&gt;Auxiliary contact unit (standard form)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=557 colSpan=13&gt;
&lt;P align=center&gt;No such model&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

