<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - High voltage isolation switch</title>
       <link>http://www.91way.com</link>
       <description>High voltage isolation switch</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:00:30</pubDate>
       <item>
           <title>[DC isolation switch]Four point DC high voltage isolation switch (handwheel type) </title>
           <link>http://www.91way.com/info_en/19354.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:49</pubDate>
           <comments></comments>
           <description>GN3-120/3-4S Four point DC High Voltage Isolation Switch (Handwheel Type)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]Four point DC high voltage isolation switch (handwheel type) </title>
           <link>http://www.91way.com/info_en/19353.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:40</pubDate>
           <comments></comments>
           <description>GN3-72/3-4S Four point DC High Voltage Isolation Switch (Handwheel Type)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]Four point DC high voltage isolation switch (flexible shaft) </title>
           <link>http://www.91way.com/info_en/19352.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:32</pubDate>
           <comments></comments>
           <description>GN3-120-4R Four point DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]Four point DC high voltage isolation switch (flexible shaft) </title>
           <link>http://www.91way.com/info_en/19351.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:23</pubDate>
           <comments></comments>
           <description>GN3-72-4R Four point DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN1-120-3R Three point DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19350.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:14</pubDate>
           <comments></comments>
           <description>GN1-120-3R three-point DC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN1-72-3R Three point DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19349.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:40:06</pubDate>
           <comments></comments>
           <description>GN1-72-3R three-point DC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN3-120-2S Two point DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19348.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:57</pubDate>
           <comments></comments>
           <description>GN3-120-2S two-point DC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN3-72/2S Two point DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19347.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:48</pubDate>
           <comments></comments>
           <description>GN3-72/2S two-point DC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN-120/3-2S Bipolar DC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/19346.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:40</pubDate>
           <comments></comments>
           <description>GN-120/3-2S Bipolar DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN-72/3-2S Bipolar DC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/19345.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:31</pubDate>
           <comments></comments>
           <description>GN-72/3-2S Bipolar DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]Single pole DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19344.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:23</pubDate>
           <comments></comments>
           <description>GN-120/2-1S Single pole DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]Single pole DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19343.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:14</pubDate>
           <comments></comments>
           <description>GN-72/2-1S Single pole DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN3-72-X Series Two point High Voltage Isolation Box </title>
           <link>http://www.91way.com/info_en/16030.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:39:05</pubDate>
           <comments></comments>
           <description>The incoming end of the GN3-72-X series two-point high-voltage switchgear is connected to the high-voltage silicon rectifier, and the outgoing end is connected to the electrostatic precipitator. The orientation of the incoming and outgoing lines of the switch box is determined based on facing the isolation switch inside the box.&lt;BR&gt;&lt;BR&gt;GN3-72-X Series Two Point High Voltage Isolation Box Technical Parameters:&lt;BR&gt;Rated working voltage: 72KV (DC average)&lt;BR&gt;Rated working current: 2A (DC average)&lt;BR&gt;&lt;BR&gt;GN3-72-X Series Two Point High Voltage Isolation Box Ordering Notice:&lt;BR&gt;Product model, name, and quantity. The high-voltage silicon rectifier matched with the switch box is used to determine the corresponding H value.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201204/20120413165024792.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 422px; WIDTH: 655px; FILTER: none&quot; border=0 hspace=0 alt=&quot;GN3-72-X Series Two Point High Voltage Isolation Box Technical Parameters and Dimensions&quot; src=&quot;/upload2012/201204/20120413165024792.jpg&quot; width=655 height=422&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN2-72 Type Four Point DC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/16029.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:38:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN2-72 Four Point DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;Indoor manually operated high-voltage switchgear, used in conjunction with high-voltage silicon rectifiers, is installed between the electrostatic precipitator and the high-voltage silicon rectifier. It is used for connecting, connecting, and grounding the high-voltage DC circuit of the electrostatic precipitator under no-load conditions.&lt;BR&gt;&lt;BR&gt;Technical parameters of GN2-72 four point DC high voltage isolation switch:&lt;BR&gt;Rated working voltage: 72KV (DC average)&lt;BR&gt;Rated working current: 2A (DC average)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120410134334477.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 393px; WIDTH: 623px; FILTER: none&quot; border=0 hspace=0 alt=&quot;GN2-72 Four Point DC High Voltage Isolation Switch Appearance and Installation Dimensions&quot; src=&quot;/upload2012/201204/20120410134334477.jpg&quot; width=623 height=393&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN2-72 Four Point DC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC isolation switch]GN1-72 type three-point DC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16028.html</link>
           <author></author>
           <guid></guid>
           <category>DC isolation switch</category>
           <pubDate>2026-6-19 17:38:48</pubDate>
           <comments></comments>
           <description>The GN1-72 three-point DC high voltage isolation switch is an indoor manually operated high voltage switchgear, which is used in conjunction with a high voltage silicon rectifier. It is installed between the electrostatic precipitator and the high voltage silicon rectifier, and is used for the connection, networking, and grounding of the high voltage DC circuit of the electrostatic precipitator under no-load conditions.&lt;BR&gt;&lt;BR&gt;Technical parameters of GN1-72 three-point DC high voltage isolation switch:&lt;BR&gt;Rated working voltage: 72KV (DC average)&lt;BR&gt;Rated working current: 2A (DC average)&lt;BR&gt;&lt;BR&gt;Ordering Notice:&lt;BR&gt;Product model, name, and quantity. (Note: A set of high-voltage silicon rectifier equipment is generally equipped with two sets of isolation switches)&lt;BR&gt;The length of the flexible shaft of the operating mechanism. (The length of the flexible shaft of the factory product is 5m-8m)&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201204/20120413164819713.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 322px; WIDTH: 683px; FILTER: none&quot; border=0 hspace=0 alt=&quot;GN1-72 three-point DC high voltage isolation switch appearance and installation dimensions&quot; src=&quot;/upload2012/201204/20120413164819713.jpg&quot; width=683 height=322&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-12DC/400A-1250A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27660.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 15:13:25</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-12DC/400A-1250A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5D/630A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27662.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 15:12:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN27-40.5D/630A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN30-12D/630A-3150A Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27663.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:47:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN30-12D/630A-3150A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-40.5-630-2000A Single pole indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27668.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:47:19</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN2-40.5-630-2000A Single pole Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201908/20190817143359558.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 326px&quot; border=0 hspace=0 alt=&quot;GN2-40.5-630-2000A Single pole Indoor AC High Voltage Isolation Switch Dimensions&quot; src=&quot;/upload2019/201908/20190817143359558.jpg&quot; width=580 height=326&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5/2500A Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27661.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:54</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN27-40.5/2500A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12D/2000A-3150A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27658.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN22-12D/2000A-3150A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-12/630A Type Four Phase Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27659.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-12/630A Four Phase Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-24 Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27657.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN22-24 Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12/400A-2000A series single pole indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27656.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:49</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN19-12/400A-2000A series single pole indoor AC high voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-24/5000A type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27655.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:41</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN10-24/5000A indoor high-voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-20/2000A-6300A series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27654.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN10-20/2000A-6300A series indoor high-voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-S series 40.5kV indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/23518.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:24</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=103&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;System constant voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;rated current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;4s thermal stability current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Dynamic stable current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;main circuit resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;¦Ì ¦¸ (not greater than)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Creepage distance ratio&lt;/DIV&gt;
&lt;DIV align=center&gt;cm/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108 colSpan=2&gt;
&lt;DIV align=center&gt;Lightning impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96 colSpan=2&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;To the ground, alternating with each other&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;To the ground, alternating with each other&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;two hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=36&gt;
&lt;DIV align=center&gt;one hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5£¨W£©/S2000-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5£¨W£©/S3150-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN19-S series 40.5kV indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]C79-400/3.3 Isolation reversing switch </title>
           <link>http://www.91way.com/info_en/23409.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:15</pubDate>
           <comments></comments>
           <description>C79-400/3.3 isolation reversing switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]C79-700/3.3 Isolation reversing switch </title>
           <link>http://www.91way.com/info_en/23408.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:07</pubDate>
           <comments></comments>
           <description>C79-700/3.3 isolation reversing switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GNF38-32KV series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19693.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GNF38-32KV series indoor isolation switch is designed and manufactured to meet the needs of the development of fixed high-voltage cabinets and ring main units towards compactness and miniaturization. It has a three station structure and a fully insulated bottom plate; And equipped with coaxial locking and a complete mechanical interlocking mechanism, the appearance is compact and small. It is the best optional switch for compact box type switchgear.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201207/20120723214432228.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 234px&quot; border=0 hspace=0 alt=&quot;GNF38-32KV series indoor high-voltage isolation switch model description&quot; src=&quot;/upload2012/201207/20120723214432228.jpg&quot; width=500 height=234&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;5¡¢ Main structural characteristics of GNF38-32KV series indoor high-voltage isolation switch&lt;BR&gt;Adopting the busbar through wall integral insulation bottom plate (APG process), the external insulation creepage distance can reach 24mm/kV, and the insulation performance is good.&lt;BR&gt;The single break point and three station structure ensure that the isolation switch cannot be grounded when closed and cannot be closed when grounded.&lt;BR&gt;Equipped with coaxial manual operation mechanism and position positioning device.&lt;BR&gt;&lt;BR&gt;6¡¢ Environmental conditions for the use of GNF38-32KV series indoor high-voltage isolating switches&lt;BR&gt;a. Surrounding air temperature: upper limit+40 ¡æ lower limit -25 ¡æ&lt;BR&gt;b. Altitude below 2000m&lt;BR&gt;c. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%&lt;BR&gt;d. The surrounding air should not be significantly polluted by corrosive or flammable gases, water vapor, etc&lt;BR&gt;e. No frequent severe vibrations&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201207/20120723214505303.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 927px&quot; border=0 hspace=0 alt=&quot;GNF38-32KV series indoor high-voltage isolation switch external dimensions and technical parameters&quot; src=&quot;/upload2012/201207/20120723214505303.jpg&quot; width=680 height=927&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201207/20120723214522602.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 843px&quot; border=0 hspace=0 alt=&quot;Installation diagram of GNF38-32KV series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201207/20120723214522602.jpg&quot; width=680 height=843&gt;&lt;/A&gt;&lt;BR&gt;GNF38-32KV series indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-10 series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/18997.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Description&lt;BR&gt;The GN2-12 series indoor AC high voltage isolation switch is a three-phase AC 50Hz high voltage switchgear used in power systems with a rated voltage of 10-35kV, for opening and closing circuits under voltage and no-load conditions. The isolation switch is equipped with CS6-2 manual operating mechanism.&lt;BR&gt;This series of isolation switches is a three-phase linkage type, consisting of a base frame, a shaft and linkage plate, post insulators, conductive switches, and static contacts. The shaft is mounted on the chassis, and a linkage plate is welded to the shaft. It is connected to the switch blade through a pull rod insulator (GN2-40.5T type epoxy glass cloth board insulation rod). The two ends of the rotating shaft extend from the chassis, and either end can be connected to the operating mechanism for opening and closing. This series of isolation switches can be installed horizontally, vertically, or diagonally.&lt;BR&gt;structure&lt;BR&gt;&lt;BR&gt;The GN2 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic Parameters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201205/20120509133349845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 517px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN2-10 series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201205/20120509133349845.jpg&quot; width=680 height=517&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201205/20120509133400454.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 267px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GN2-10 series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201205/20120509133400454.jpg&quot; width=680 height=267&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201205/20120509133417742.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 296px&quot; border=0 hspace=0 alt=&quot;GN2-10 series indoor high-voltage isolation switch external dimensions&quot; src=&quot;/upload2012/201205/20120509133417742.jpg&quot; width=680 height=296&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-35T Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/18996.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:42</pubDate>
           <comments></comments>
           <description>The GN2-10-35 series indoor high-voltage isolation switch is a three-phase AC 50Hz high-voltage switchgear used in power systems with a rated voltage of 10-35kV, for opening and closing circuits under no-load voltage conditions.&lt;BR&gt;Isolation switches with a rated current of 2000A and below are equipped with CS6-2T type manual operating mechanisms, while isolation switches with a rated current of 3000A are equipped with CS7 type manual operating mechanisms.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN2-35T indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;28%&quot;&gt;
&lt;DIV align=center&gt;Project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1000, 2000, 3000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;400, 600, 1000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80, 85, 100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;52, 64, 70&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40, 51, 70&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;14. 25, 27.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Installation dimensions of GN2-35T indoor high-voltage isolation switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201205/20120509132946802.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 346px&quot; border=0 hspace=0 alt=&quot;GN2-35T Indoor High Voltage Isolation Switch Appearance and Installation Dimensions&quot; src=&quot;/upload2012/201205/20120509132946802.jpg&quot; width=680 height=346&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5C/630A-2000A series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16403.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:34</pubDate>
           <comments></comments>
           <description>GN27-40.5C/630A-2000A series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-10~20/4000A-9000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16402.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:26</pubDate>
           <comments></comments>
           <description>GN10-10-20/4000A-9000A indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/8000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16401.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:17</pubDate>
           <comments></comments>
           <description>GN22-12/8000A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/6300A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16400.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:08</pubDate>
           <comments></comments>
           <description>GN22-12/6300A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12C/2000A-4000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16399.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:00</pubDate>
           <comments></comments>
           <description>GN22-12C/2000A-4000A Indoor High Voltage Isolation Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/2000A-5000A High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16398.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:51</pubDate>
           <comments></comments>
           <description>GN22-12/2000A-5000A High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-12/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16397.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:43</pubDate>
           <comments></comments>
           <description>GN16-12/400A-1250A Indoor High Voltage Isolation Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN15-12/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16396.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:34</pubDate>
           <comments></comments>
           <description>GN15-12/400A-1250A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12CST/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16395.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:26</pubDate>
           <comments></comments>
           <description>GN19-12CST/400A-1250A indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12ST/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16394.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:18</pubDate>
           <comments></comments>
           <description>GN19-12ST/400A-1250A indoor isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN28-12 series indoor high-voltage combination isolation switch </title>
           <link>http://www.91way.com/info_en/8349.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:10</pubDate>
           <comments></comments>
           <description>The GN28-12 series indoor high-voltage combination isolation switch (hereinafter referred to as the isolation switch) is an indoor device with a rated voltage of 12kV three-phase AC 50Hz. Used for voltage and no-load division circuits. Suitable for XGN1 type box cabinet.&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;&lt;BR&gt;a. The ambient temperature is not higher than+40 ¡æ and not lower than -10 ¡æ&lt;BR&gt;b. The monthly average relative humidity should not exceed 90%&lt;BR&gt;c. Altitude not exceeding 1000m&lt;BR&gt;&lt;BR&gt;Structure and Characteristics&lt;BR&gt;GN28-12 type isolation switch is a combination type, consisting of two types: denominator knife isolation switch and line side isolation switch, mainly composed of contacts, contact knives, insulation components, and frames. The busbar isolation switch, line isolation switch, bypass isolation switch, and one set of grounding knife switches on each side of the switch are assembled on a frame, which not only reduces the volume, but also facilitates the installation of the entire set, eliminating the workload of operators hanging and dismantling grounding wires, as well as personal and equipment accidents caused by improper hanging and dismantling of grounding wires. The isolation switch is equipped with a rotating fully mechanical locking mechanism, which has the characteristics of easy and flexible operation, and reliable five prevention functions.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-12D type high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/8206.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:01</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview of GN24-1D High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;&lt;BR&gt;1000m altitude&lt;BR&gt;Surrounding air temperature: -30 ¡æ~+40 ¡æ; &amp;nbsp;&lt;BR&gt;Relative humidity of the surrounding environment: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;No severe vibration oscillation impact site; &amp;nbsp;&lt;BR&gt;A place without fire, explosion, corrosive metal, toxic gases that damage insulation, and conductive dust;&lt;BR&gt;&lt;BR&gt;GN24-1D High Voltage Isolation Switch Model and Meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911119408380.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;GN24-1D High Voltage Isolation Switch Model Description&quot; src=&quot;/upload2009/200911/200911119408380.gif&quot; width=500 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN24-1D High Voltage Isolation Switch Appearance and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;Figure 1, GN24-12 (D) type&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/2009111194037254.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 302px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194037254.gif&quot; width=577 height=302&gt;&lt;/A&gt;&lt;BR&gt;Figure 2, GN24-1D (C) type&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194058592.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 274px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194058592.gif&quot; width=577 height=274&gt;&lt;/A&gt;&lt;BR&gt;Figure 3: GN24-1D Type II&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194111828.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 242px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194111828.gif&quot; width=577 height=242&gt;&lt;/A&gt;&lt;BR&gt;Figure 4: GN24-1D (C) Type II&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194125311.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 576px; HEIGHT: 264px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 4 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194125311.gif&quot; width=576 height=264&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN24-1D High Voltage Isolation Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN38-10 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7192.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:53</pubDate>
           <comments></comments>
           <description>GN38 lower isolation switch&lt;BR&gt;&lt;BR&gt;Lower isolation coaxial right operation three workstations&lt;BR&gt;Manual integrated mechanism&lt;BR&gt;(Capable of grounding and closing)&lt;BR&gt;structural characteristics&lt;BR&gt;&lt;BR&gt;1. The isolation switch and grounding switch are integrated into one unit&lt;BR&gt;2. Grounding switch equipment related to short-circuit current capability&lt;BR&gt;3. Isolation and grounding switches have complete mechanical locking&lt;BR&gt;4. The outgoing terminal adopts side installation&lt;BR&gt;5. The height of the cable outlet is effectively guaranteed&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN38-10 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7191.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:45</pubDate>
           <comments></comments>
           <description>GN38-10 series high voltage isolation switch&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The GN38-10 series high-voltage isolating switch adopts a busbar through wall insulation bottom plate, which completely isolates the switchgear busbar room from the circuit breaker room&lt;BR&gt;2. Equipped with a cross axis manual integrated operating mechanism, which not only ensures the mechanical performance of the isolation switch, but also reduces the operating height for convenient operation&lt;BR&gt;3. Single breakpoint three station structure ensures reliable switch operation&lt;BR&gt;GN38-10 series high-voltage isolating switch is equipped with a complete mechanical interlocking device&lt;BR&gt;&lt;BR&gt;Coaxial &quot;refers to the transmission main shaft and the operating mechanism shaft being the same shaft&lt;BR&gt;'Off axis' refers to the fact that the main transmission shaft and the operating mechanism shaft are two separate axes, with connecting rods or gears used for transmission in the middle&lt;BR&gt;Integrated mechanism &quot;refers to the combination of isolation switch and operating mechanism, whose external dimensions, installation method, and performance indicators are carefully calibrated before the product leaves the factory.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24 series isolating switch </title>
           <link>http://www.91way.com/info_en/6810.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:36</pubDate>
           <comments></comments>
           <description>GN24 series isolation switch&lt;BR&gt;&lt;BR&gt;GN24-10D/400A&lt;BR&gt;GN24-10DC/400A&lt;BR&gt;GN24-10D/630A&lt;BR&gt;GN24-10DC/630A&lt;BR&gt;GN24-10D/1000A&lt;BR&gt;GN24-10DC/1000A&lt;BR&gt;GN24-10D/1250A&lt;BR&gt;GN24-10DC/1250A&lt;BR&gt;&lt;BR&gt;The GN24-10D series indoor high-voltage isolating switch with grounding knife (hereinafter referred to as the isolating switch) is an indoor high-voltage switchgear with a rated voltage of 12KV or below and three-phase AC 50Hz. It is used for breaking and closing circuits in power systems with voltage and no load. The GN24-10D series isolating switch has three working positions: closing, opening, and grounding, and can be operated step by step. It has the anti misoperation performance of preventing live hanging grounding wires and closing with grounding. It is a necessary component to meet the requirements of &quot;three defenses&quot;. The grounding contact knife can be used for: when electrical equipment is powered off for maintenance, the semi grounding contact knife can be closed to create a network artificial short circuit, ensuring that maintenance personnel receive reliable &quot;ground potential&quot; protection.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;4S thermal stability current&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;GN24-12D&lt;/P&gt;
&lt;P align=center&gt;GN24-12DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;12kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;400A&lt;BR&gt;630A&lt;BR&gt;1000A&lt;BR&gt;1250A&lt;BR&gt;2000A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;20kA&lt;/P&gt;
&lt;P align=center&gt;31.5kA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]RH-B series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/4540.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:28</pubDate>
           <comments></comments>
           <description>Technical parameters of RH-B series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=110 align=middle&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=70 align=middle&gt;rated voltage&lt;/TD&gt;
&lt;TD rowSpan=2 width=103 align=middle&gt;rated current&lt;/TD&gt;
&lt;TD rowSpan=2 width=116 align=middle&gt;4S thermal stability current&lt;/TD&gt;
&lt;TD rowSpan=2 width=111 align=middle&gt;Dynamic stable voltage&lt;/TD&gt;
&lt;TD width=141 align=middle&gt;Dynamic stable voltage&lt;/TD&gt;
&lt;TD width=175 align=middle&gt;Impact withstand voltage&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=83&gt;relatively&lt;/TD&gt;
&lt;TD width=74&gt;Fracture gate&lt;/TD&gt;
&lt;TD width=101&gt;relatively&lt;/TD&gt;
&lt;TD width=90&gt;Fracture gate&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;RH-B&lt;/TD&gt;
&lt;TD width=70&gt;eleven&lt;/TD&gt;
&lt;TD width=103&gt;forty-four&lt;/TD&gt;
&lt;TD width=116&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=111&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=83&gt;seventy-five&lt;/TD&gt;
&lt;TD width=74&gt;ninety-five&lt;/TD&gt;
&lt;TD width=101&gt;38&amp;nbsp;&lt;/TD&gt;
&lt;TD width=90&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;RH-B&lt;/TD&gt;
&lt;TD width=70&gt;thirty-three&lt;/TD&gt;
&lt;TD width=103&gt;six hundred&lt;/TD&gt;
&lt;TD width=116&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=111&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=83&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD width=74&gt;one hundred and ninety-five&lt;/TD&gt;
&lt;TD width=101&gt;seventy&lt;/TD&gt;
&lt;TD width=90&gt;eighty&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RH-B series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN5 Indoor single-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/4486.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GN5 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=121&gt;model&lt;/TD&gt;
&lt;TD width=72&gt;Product Code&lt;/TD&gt;
&lt;TD width=87&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD width=116&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD width=81&gt;Rated current A&lt;/TD&gt;
&lt;TD width=137&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD width=122&gt;5-second thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD width=64&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-two&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;twenty-five point five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-three&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;four point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;twenty-five point five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;six point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-seven&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/1250&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and forty-one&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;seventeen&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Appearance and installation dimensions of GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=93&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Factory code&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Rated current A&lt;/TD&gt;
&lt;TD colSpan=4&gt;Main dimensions (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=93&gt;H&lt;/TD&gt;
&lt;TD width=93&gt;h&lt;/TD&gt;
&lt;TD width=93&gt;h1&lt;/TD&gt;
&lt;TD width=123&gt;t&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-two&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-three&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;four hundred and thirty&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and forty&lt;/TD&gt;
&lt;TD&gt;two hundred and forty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-six&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-seven&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200810/2008101133349119.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 560px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Diagram of GN5 Indoor Single phase High voltage Isolation Switch&quot; src=&quot;/uploadfiles/200810/2008101133349119.jpg&quot; width=500 height=560&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200810/200810113344777.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 392px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN5 indoor single-phase high voltage isolation switch&quot; src=&quot;/uploadfiles/200810/200810113344777.jpg&quot; width=500 height=392&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-40.5(W) type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/4186.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/2008723163146845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 356px; HEIGHT: 677px&quot; border=0 hspace=0 alt=&quot;GN2-40.5 (W) Indoor High Voltage Isolation Switch Description&quot; src=&quot;/uploadfiles/200807/2008723163146845.jpg&quot; width=356 height=677&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200807/2008723163215529.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=&quot;GN2-40.5 (W) Indoor High Voltage Isolation Switch Outline and Installation Dimensional Drawing&quot; src=&quot;/uploadfiles/200807/2008723163215529.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated current/A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Dynamic stability current (peak value)/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Thermal stability current (effective value)/kA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6s&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-12/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-12/3000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-20/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/400 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/2000 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630-¢ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630-¢ò&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/1250-¢ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/1250-¢ò&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN2-40.5 (W) type indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GNF38-12/630A type indoor ring main unit isolation switch </title>
           <link>http://www.91way.com/info_en/2665.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:03</pubDate>
           <comments></comments>
           <description>The LZFW-35GY current transformer adopts our company's unique technology, which integrates outdoor epoxy resin and silicone rubber into a composite insulation form. It is not a general form of silicone rubber umbrella sheet bonding, and the overall product is firm. It belongs to the new generation of outdoor products. Widely used in outdoor or indoor power systems with a rated frequency of 50 Hz and a rated voltage of 35 kV or below, it is also used for metering, measurement, and monitoring protection.&lt;BR&gt;&lt;BR&gt;Characteristics of GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;1. This product is made of outdoor epoxy resin, and the non winding part is coated with silicone rubber and fully vacuum cast. It is a fully enclosed insulation and pillar structure. The product fully combines the advantages of good processability and strong heat dissipation performance of outdoor epoxy resin with the strong UV resistance, good water addition, anti fog flash and anti pollution flash ability of silicone rubber, while complementing each other's shortcomings, to achieve good internal and external insulation performance. The product has anti fog and anti humidity, anti pollution flash, excellent resistance to cold and hot shock, good environmental adaptability, strong hydrophobicity and anti UV linear ability, anti-aging and arc resistance, long service life, and can fully meet outdoor use conditions.&lt;BR&gt;2. The product adopts a ring-shaped ultra microcrystalline alloy iron core and imported high-quality silicon steel sheet coil iron core. Has high metrological accuracy, stable error, and low instrument security factor; Stable protection level performance and high accuracy limit coefficient. The transformer has the characteristics of low power consumption and minimal residual magnetism.&lt;BR&gt;3. According to user requirements, production can be done in various ratios and multi-level combinations. Beneficial for power station expansion and effectively saving investment.&lt;BR&gt;4. The product can be installed independently or used in conjunction with outdoor circuit breakers and other outdoor equipment. It has the characteristics of easy installation and replacement, and maintenance free use.&lt;BR&gt;&lt;BR&gt;Usage conditions for GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;Fully meet the high-altitude outdoor product usage conditions specified in IEC185-87 and GB1208-1997, as well as the requirements of Level II pollution prevention level.&lt;BR&gt;&lt;BR&gt;Basic technical parameters of GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;1. Rated voltage 35 kV&lt;BR&gt;2. Rated altitude ¡Ü 4000 meters&lt;BR&gt;3. Rated insulation level 40.5/95/185 kV&lt;BR&gt;4. Rated primary current 20-3000 A&lt;BR&gt;5. Rated secondary current 5A or 1A&lt;BR&gt;6. Partial discharge capacity in accordance with GB1208-1997 standard, apparent discharge capacity ¡Ü 20 pC&lt;BR&gt;7. Dynamic thermal stability current: 1 second thermal current=110 I1n; Dynamic stability current=2.5 Ith&lt;BR&gt;8. Rated primary current, level combination, and corresponding rated output relationship Rated primary current&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Rated primary current&lt;BR&gt;£¨A£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Accurate level combination&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Rated secondary output (VA)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2£¨0.2S£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P10&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;20~600&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2£¨0.2S£©/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.5/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2 (or 0.2S)/0.5/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2 (or 0.2S)/10P/10P&lt;/P&gt;&lt;/TD&gt;
&lt;P&gt;Overview&lt;BR&gt;&lt;BR&gt;The GNF38-12KV series indoor ring main unit isolation switch is designed and manufactured to meet the needs of the development of fixed high-voltage cabinets and ring main units towards compactness and miniaturization. It has a three station structure and a fully insulated bottom plate; And equipped with coaxial locking and a complete mechanical interlocking mechanism, the appearance is compact and small. It is the best optional switch for compact box type switchgear.&lt;BR&gt;&lt;BR&gt;Switch model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385648411.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 530px; HEIGHT: 176px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A type indoor ring main unit isolation switch model description&quot; src=&quot;/uploadfiles/200710/2007101385648411.jpg&quot; width=530 height=176&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Reference standards&lt;BR&gt;&lt;BR&gt;GB1985-1989 AC High Voltage Disconnectors and Grounding Switches&lt;BR&gt;IEC129-84 AC isolating switches and grounding switches&lt;BR&gt;&lt;BR&gt;Normal usage conditions&lt;BR&gt;&lt;BR&gt;a. Surrounding air temperature: upper limit+40 ¡æ lower limit -25 ¡æ&lt;BR&gt;b. Altitude not exceeding 2000m&lt;BR&gt;c. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%&lt;BR&gt;d. The surrounding air should not be significantly polluted by corrosive or flammable gases, water vapor, etc&lt;BR&gt;e. No frequent severe vibrations&lt;BR&gt;&lt;BR&gt;Main technology of GNF38-12/630A indoor ring main unit isolation switch
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385715434.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 347px&quot; border=0 hspace=0 alt=&quot;Technical parameter table of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385715434.jpg&quot; width=550 height=347&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Main structural features&lt;BR&gt;&lt;BR&gt;Adopting busbar through wall integral insulation bottom plate (APG process), the external insulation creepage distance can reach 24MM/kV, and the insulation performance is good.&lt;BR&gt;The single break point and three station structure ensure that the isolation switch cannot be grounded when closed and cannot be closed when grounded.&lt;BR&gt;Equipped with coaxial manual operation mechanism and position positioning device.&lt;BR&gt;&lt;BR&gt;Installation and debugging&lt;BR&gt;&lt;BR&gt;After opening the box, the product should be checked for any damage or rust, the product nameplate and certificate of conformity should match the purchase order, and the packing list should match the actual product and be in good condition.&lt;BR&gt;Clean the surface of dust and dirt.&lt;BR&gt;Check if the screws at the main connecting parts of the switch are loose. If so, tighten and adjust them.&lt;BR&gt;Apply industrial Vaseline oil to the mechanical friction parts.&lt;BR&gt;According to the position of the high-voltage cabinet and the ring main unit, installation is required, and attention should be paid to the insulation distance between the live part and the ground when the switch is opened, which should be greater than 125cm.&lt;BR&gt;After the switch is installed, it should be operated without load 3-5 times, and the opening, closing, and grounding signs should be checked to ensure that they match the corresponding operation. There should be no abnormal phenomena such as jamming during operation.&lt;BR&gt;The pressure of the contact spring between the moving and stationary contacts has been adjusted before leaving the factory, and users do not need to adjust it again.&lt;BR&gt;The connection between the switch and the busbar must have good contact and be securely fixed.&lt;BR&gt;&lt;BR&gt;Usage and Maintenance&lt;BR&gt;&lt;BR&gt;The opening, closing, and grounding positions of the switch are determined and locked, and the mechanical interlocking action is performed. The identification of each position is completed by the operating mechanism.&lt;BR&gt;Before operation, it is necessary to check whether the mechanism is safe and reliable.&lt;BR&gt;First, turn the wrench on the panel towards the operating axis, then release it. Insert the handle and rotate it in the direction indicated by the arrow on the panel. Once the operation is in place, the wrench on the panel will automatically return to its original position. Repeat the above steps when operating again.&lt;BR&gt;When the operating mechanism leaves the factory, its internal sliding parts are coated with lubricating grease. If the user finds any obstruction during operation, they can open the front cover and apply lubricating grease to the sliding parts.&lt;BR&gt;The maintenance of the switch is not carried out with electricity, and it is not allowed to pull the switch with load.&lt;BR&gt;During maintenance, the fixing screws of the insulation base and insulation support, the spring compression of the moving contact knife, the shaft retaining ring on the connecting pin between the insulation rod and the insulation crank arm, and the opening on the connecting pin between the insulation rod and the moving contact knife should be carefully inspected. If there are any abnormalities, they should be adjusted and maintained in a timely manner.&lt;BR&gt;When the contact positions of the static contact and the moving contact blade are found to be burnt or blackened during maintenance, it is not allowed to use a file to lower the contact points. Only sandpaper can be used to polish them, and then industrial Vaseline grease can be applied.&lt;BR&gt;During maintenance, attention should be paid to observing the deformation of the clamping spring of the moving contact blade. If there is any deformation, it should be adjusted or replaced in a timely manner.&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385747430.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 396px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A type indoor ring main unit isolation switch appearance and installation dimension diagram&quot; src=&quot;/uploadfiles/200710/2007101385747430.jpg&quot; width=560 height=396&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/200710138584177.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 311px; HEIGHT: 441px&quot; border=0 hspace=0 alt=&quot;Installation method of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/200710138584177.jpg&quot; width=311 height=441&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Installation method&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385921404.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 355px&quot; border=0 hspace=0 alt=&quot;Installation diagram of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385921404.jpg&quot; width=560 height=355&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385935871.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 340px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A indoor ring main unit isolation switch left and right operation diagram&quot; src=&quot;/uploadfiles/200710/2007101385935871.jpg&quot; width=560 height=340&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385947853.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 450px; HEIGHT: 322px&quot; border=0 hspace=0 alt=&quot;Front view of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385947853.jpg&quot; width=450 height=322&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GNF38-12/630A type indoor ring main unit isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/P&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]DGN-12 type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/1629.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:55</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=257&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=145&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;630, 1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20. 31.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50, 80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time continuous current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated insulation level 1-minute power frequency withstand voltage&lt;BR&gt;Lightning impulse withstand voltage (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;BR&gt;kV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-two&lt;BR&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DGN-12 indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-35 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1551.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:46</pubDate>
           <comments></comments>
           <description>GN19-35 series high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]DGN-12D series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1230.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:38</pubDate>
           <comments></comments>
           <description>DGN-12D series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN36-12 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1229.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:30</pubDate>
           <comments></comments>
           <description>GN36-12 series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-10(C) series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1228.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-10 (C) series high-voltage isolating switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075811771.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 643px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN24-10 (C) series high-voltage isolating switch&quot; src=&quot;/upload2013/201303/20130317075811771.jpg&quot; width=643 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075820799.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 638px&quot; border=0 hspace=0 alt=&quot;GN24-10 (C) series high-voltage isolation switch external dimensions&quot; src=&quot;/upload2013/201303/20130317075820799.jpg&quot; width=680 height=638&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075829765.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 643px; HEIGHT: 638px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GN24-10 (C) series high-voltage isolation switch&quot; src=&quot;/upload2013/201303/20130317075829765.jpg&quot; width=643 height=638&gt;&lt;/A&gt;&lt;BR&gt;GN24-10 (C) series high-voltage isolating switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-35/2000 High voltage and high current isolation switch </title>
           <link>http://www.91way.com/info_en/1227.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:13</pubDate>
           <comments></comments>
           <description>GN16-35/2000 High Voltage and High Current Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19 Indoor three-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/872.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:04</pubDate>
           <comments></comments>
           <description>The GN19-10 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;The GN19-10C indoor three-phase high voltage isolation switch consists of a base, a pair of ceramic insulators, a ceramic sleeve, an operating ceramic insulator, and a conductive part.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KV (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;10s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;weight&lt;BR&gt;kg&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-seven&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/1000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/1000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN19 indoor three-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10 Type Indoor Single (Three) Phase High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/871.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:56</pubDate>
           <comments></comments>
           <description>The GN10 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts. Can be used for single-phase or three-phase connection. Can be operated with manual or electric mechanisms.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot;&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;7%&quot;&gt;rated&lt;BR&gt;Voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;It's a senior engineer&lt;BR&gt;Operating voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot;&gt;Dynamic stability current KA&lt;BR&gt;(Peak value)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;10s thermal stability current KA&lt;BR&gt;(Effective value)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Main dimensions (mm)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot; align=middle&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;H&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;h&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/3000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;70-5&lt;/TD&gt;
&lt;TD&gt;six hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty-five&lt;/TD&gt;
&lt;TD&gt;¡«54&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/4000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;85-5&lt;/TD&gt;
&lt;TD&gt;seven hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty&lt;/TD&gt;
&lt;TD&gt;¡«60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/5000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;five thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«135&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/6000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;six thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«145&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/3000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;70-5&lt;/TD&gt;
&lt;TD&gt;eight hundred and ten&lt;/TD&gt;
&lt;TD&gt;four hundred and sixty&lt;/TD&gt;
&lt;TD&gt;¡«77&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/4000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;85-5&lt;/TD&gt;
&lt;TD&gt;eight hundred and sixty&lt;/TD&gt;
&lt;TD&gt;four hundred and ninety-five&lt;/TD&gt;
&lt;TD&gt;¡«87&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/5000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«150&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/6000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;six thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«160&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/8000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;eight thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«180&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/10000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;ten thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«180&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN10 indoor single-phase and three-phase high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN6,GN8 Indoor three-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/870.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:48</pubDate>
           <comments></comments>
           <description>The GN6-6 and 10T indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;GN8-6, 10T - ¢ñ, ¢ò type indoor three-phase high voltage isolation switches consist of a base, pillar porcelain insulators, porcelain sleeves, operating insulators, and conductive parts.&lt;BR&gt;GN8-6, 10T-III indoor three-phase high voltage isolation switch consists of a base, porcelain bushing, operating porcelain insulator, and conductive part&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;5-second thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/200, GN8-6T/200- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/200, GN8-6T/400- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/630, GN8-6T/630- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/200, GN8-10T/200- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/400, GN8-10T/400- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/630, GN8-10T/630- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/1250, GN8-10T/1250- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-35T-1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009102223837819.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 592px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN6 and GN8 indoor three-phase high voltage isolation switches&quot; src=&quot;/upload2009/200910/2009102223837819.jpg&quot; width=350 height=592&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN1 Indoor single-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/869.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:39</pubDate>
           <comments></comments>
           <description>The GN1 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;P align=center&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;10s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;weight&lt;BR&gt;kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-10/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-20/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-35/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-35/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;Appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200810/2008101133254717.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Dimensional Drawing of GN1 Indoor Single phase High voltage Isolation Switch&quot; src=&quot;/uploadfiles/200810/2008101133254717.jpg&quot; width=680 height=220&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN1 type indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/835.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:31</pubDate>
           <comments></comments>
           <description>GN22-12 (C) Indoor AC High Voltage Isolation Switch Model and Its Meaning&lt;BR&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude: not exceeding 1000m;&lt;BR&gt;+Surrounding air temperature: -30 ¡æ to+40 ¡æ;&lt;BR&gt;+Relative humidity of the surrounding environment: daily average not exceeding 95%; Monthly average not exceeding 90%;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+Safe place: No fire, flammable, explosive, severely polluted, chemically corroded, or violently vibrating places.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN22-12 (C) indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;1600~2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;2500~3150&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-circuit withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-time duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;
&lt;DIV align=left&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Inter pole, pole to ground 42 fracture 49&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Lightning impulse withstand voltage (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Inter pole, pole to ground 75 fracture 85&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensions (The following image can be clicked to enlarge):&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061030213842323.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 166px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 1&quot; src=&quot;/uploadfiles/200610/20061030213842323.jpg&quot; width=245 height=166&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021394155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 166px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 2&quot; src=&quot;/uploadfiles/200610/2006103021394155.jpg&quot; width=245 height=166&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;Figure 1: Dimensions of GN22-12 Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;Model number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;GN22-12/1600-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;three hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;five hundred and twenty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;GN22-12/2500-3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;five hundred and thirty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;four hundred and ninety-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021418587.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 196px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 3&quot; src=&quot;/uploadfiles/200610/2006103021418587.jpg&quot; width=500 height=196&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021423818.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 165px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 4&quot; src=&quot;/uploadfiles/200610/2006103021423818.jpg&quot; width=245 height=165&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Figure 2: Dimensions of GN22-12C Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061030214346155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 340px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Outline and Installation Dimensional Drawing 5&quot; src=&quot;/uploadfiles/200610/20061030214346155.jpg&quot; width=340 height=170&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021444701.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 340px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 6&quot; src=&quot;/uploadfiles/200610/2006103021444701.jpg&quot; width=340 height=170&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN22-12C/1600-2000 High Voltage Isolation Switch Terminal Diagram GN22-12C/2500-3150 High Voltage Isolation Switch Terminal Diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN22-12C/1600-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN22-12C/2500-3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-seven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN22-12 (C) Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-7.2/400-20 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/830.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:23</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (KG)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN16-7.2/400-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;530*360*360&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN16-7.2/400-20 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN8-3.6 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/829.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:14</pubDate>
           <comments></comments>
           <description>GN8-3.6 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak value&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Equipped with a handle&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR bgColor=#ffffff&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN8-3.6/S400-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;480*248*170&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;370*175&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030193214485.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN8-3.6 high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061030193214485.gif&quot; width=680 height=500&gt;&lt;/A&gt;&lt;BR&gt;GN8-3.6 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/828.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:06</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030192853284.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;GN10 High Voltage Isolation Switch Outline and Installation Dimensional Drawing&quot; src=&quot;/uploadfiles/200610/20061030192853284.gif&quot; width=680 height=580&gt;&lt;/A&gt;&lt;BR&gt;GN10 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN9-3.6/S200-5 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/827.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN9-3.6/S200-5 indoor one-way isolation switch, suitable for 3600V level electrical control cabinets, plays the role of isolating circuits, mainly used in the fields of petroleum, chemical industry, etc.&lt;BR&gt;&lt;BR&gt;SGN9-3.6/S200-5 indoor bidirectional isolation switch is used in 3600V electrical control cabinets to isolate circuits, ground circuits, or phase change circuits.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030192442363.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 600px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN9-3.6/S200-5 high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061030192442363.gif&quot; width=680 height=600&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;GN9-3.6/S200-5 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak value&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Equipped with a handle&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN9-3.6/S200-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;320*224*175&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;184*100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HD12-200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SGN9-3.6/S200-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300*260*175&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;230*100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HD13-200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN25-10 type high current and high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/767.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:49</pubDate>
           <comments></comments>
           <description>GN25-10/2000¡¢ The 3000 type household three high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN25-10 high current and high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=113&gt;model&lt;/TD&gt;
&lt;TD width=72&gt;Product Code&lt;/TD&gt;
&lt;TD width=92&gt;rated voltage&lt;/TD&gt;
&lt;TD width=130&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD width=122&gt;Rated current A&lt;/TD&gt;
&lt;TD width=84&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD width=116&gt;5-second thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD width=93&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN25-10T/2000&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand one hundred and fifteen&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;seventy-four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN25-10T/3000&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand one hundred and nineteen&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;three thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820023910.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 440px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Dimensional Drawing of GN25-10 High Current High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/2006102820023910.jpg&quot; width=680 height=440&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN25-10 high current and high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5 series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/444.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:41</pubDate>
           <comments></comments>
           <description>GN27-40.5 indoor high-voltage isolation switch is a new type of product. Suitable for rated voltage&lt;BR&gt;40.5V£¬ In a 50Hz AC power system, it is designed and produced as a replacement for old products to open and close circuits with voltage and no load. Can be paired with high-voltage switchgear or used independently. Equipped with CS6-2 operating mechanism. All adopt reinforced insulation design, which can meet the requirements for use in Class II polluted areas. Product features:&lt;BR&gt;&lt;BR&gt;Design scientifically, reasonably, and structurally innovative; &amp;nbsp;&lt;BR&gt;Multi contact, rotating contact, good self-cleaning ability, and improved heat dissipation capability; &amp;nbsp;&lt;BR&gt;The contact point is within two surfaces, with low operating torque, high contact pressure, and easy adjustment; &amp;nbsp;&lt;BR&gt;Adopting a large climbing distance to enhance insulation capability and withstand voltage to meet the highest requirements; &amp;nbsp;&lt;BR&gt;Installing bearings on the shaft increases its service life and makes it easy to operate.&lt;BR&gt;&lt;BR&gt;Technical parameters of GN27-40.5 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=68&gt;
&lt;DIV align=center&gt;Rated voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;DIV align=center&gt;4s rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=76&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;DIV align=center&gt;Lightning impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;95/118&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;185/125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061121101213943.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 700px&quot; border=0 hspace=0 alt=&quot;GN27-40.5 Series Indoor High Voltage Isolation Switch Selection Instructions&quot; src=&quot;/uploadfiles/200611/20061121101213943.jpg&quot; width=680 height=700&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061121101243194.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200611/20061121101243194.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 129px&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center height=129&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=13 width=109&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;Rated voltage KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Maximum working voltage KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Dynamic stability current KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;Thermal stability current KA-S&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;16-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;25-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;36-10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35-C1¡¢C2/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;16-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;CN27-35C1¡¢C2/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;25-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35C1¡¢C2/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;36-10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085272117509.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 266px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/20085272117509.gif&quot; width=600 height=266&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35/630¡¢ Outline and installation diagram of 1250 and 1600 isolation switches&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852721133787.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 259px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/200852721133787.gif&quot; width=600 height=259&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35C2/630¡¢ Appearance and installation diagram of 1250 and 1600 isolation switches&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852721145401.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 263px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/200852721145401.gif&quot; width=600 height=263&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35C1-630¡¢ Appearance and installation diagram of 1250 and 1600 isolation switches&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;Ordering Instructions&lt;BR&gt;When placing an order, please specify the product model, rated voltage, rated current, and if installing composite insulators with H&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN30-12(D) Rotating indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/351.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:32</pubDate>
           <comments></comments>
           <description>&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 309px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200610/20061024233622526.jpg&quot; width=500 height=309&gt;&lt;/DIV&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude: 1000-3000m;&lt;BR&gt;+Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ;&lt;BR&gt;+Relative humidity of the surrounding environment: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+Places without severe dust, chemical corrosion, and explosive substances;&lt;BR&gt;+No places with frequent and severe vibrations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN30-12 (D) rotary indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;4s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/100-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/2000-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/2500-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/3150-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/2000-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/2500-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/3150-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Appearance and Installation Dimensions&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 1&quot; src=&quot;/uploadfiles/200610/20061024233635863.jpg&quot; width=245 height=151&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 137px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 2&quot; src=&quot;/uploadfiles/200610/20061024233644318.jpg&quot; width=137 height=151&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 114px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN30-12 (D) rotary indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061024233652616.jpg&quot; width=114 height=151&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 1 Outline drawing of GN30-12/630, 1000 indoor AC high voltage isolation switch 630A wiring terminal diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 4&quot; src=&quot;/uploadfiles/200610/2006102423370570.jpg&quot; width=245 height=145&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 131px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 5&quot; src=&quot;/uploadfiles/200610/2006102423378446.jpg&quot; width=131 height=145&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 114px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 6&quot; src=&quot;/uploadfiles/200610/20061024233719478.jpg&quot; width=114 height=145&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 2: Outline drawing of GN30-12/630, 1000 indoor AC high voltage isolation switch 1000A wiring terminal diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 168px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 7&quot; src=&quot;/uploadfiles/200610/20061024233727407.jpg&quot; width=245 height=168&gt;&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 138px; HEIGHT: 168px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 8&quot; src=&quot;/uploadfiles/200610/20061024233733914.jpg&quot; width=138 height=168&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 3 Outline drawing of GN30-12D/630, 1000 indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;CN30-12&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;CN30-12D&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;630A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;630A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«560&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«315&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«580&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«332&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«550&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«610&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«575&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«615&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«245&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 144px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 9&quot; src=&quot;/uploadfiles/200610/20061024233741593.jpg&quot; width=245 height=144&gt;&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 125px; HEIGHT: 144px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 10&quot; src=&quot;/uploadfiles/200610/20061024233748742.jpg&quot; width=125 height=144&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Figure 4 Outline drawing of GN30-12/1250 indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2 series indoor high-voltage isolation switch GN2-10/2000 GN2-10/3000</title>
           <link>http://www.91way.com/info_en/335.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:23</pubDate>
           <comments></comments>
           <description>structure&lt;BR&gt;The GN2 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts. Among them: GN2-35/630-I, II; The 1250-I and II type indoor three-phase high voltage isolation switches consist of a base, pillar porcelain insulators, porcelain sleeves, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN2 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 400px&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center height=400&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=170&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=69&gt;Product Code&lt;/TD&gt;
&lt;TD rowSpan=2 width=86&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD rowSpan=2 width=119&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=80&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2 width=161&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD rowSpan=2 width=59&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90 align=middle&gt;10s&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;6s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-one&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/3000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-two&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty-seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-20/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-three&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-seven&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and two&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and fourteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-eight&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and three&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and nineteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and sixty-four&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty-five&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/2000 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and four&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty-five&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;two hundred and six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630-¢ñ&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-five&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixteen&lt;/TD&gt;
&lt;TD&gt;two hundred and twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630-¢ò&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-six&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixteen&lt;/TD&gt;
&lt;TD&gt;two hundred and twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/1250-¢ñ&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-seven&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty-one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/1250-¢ò&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-eight&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty-one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN2 series indoor high-voltage isolation switch appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 200px&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center height=200&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=101&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=81&gt;Product Code&lt;/TD&gt;
&lt;TD colSpan=8&gt;Main dimensions (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=46 align=middle&gt;L&lt;/TD&gt;
&lt;TD width=44 align=middle&gt;L1&lt;/TD&gt;
&lt;TD width=44 align=middle&gt;H&lt;/TD&gt;
&lt;TD width=66 align=middle&gt;h&lt;/TD&gt;
&lt;TD width=66 align=middle&gt;A&lt;/TD&gt;
&lt;TD width=59 align=middle&gt;A1&lt;/TD&gt;
&lt;TD width=61 align=middle&gt;A1&lt;/TD&gt;
&lt;TD width=49 align=middle&gt;B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=22&gt;GN2-10/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-one&lt;/TD&gt;
&lt;TD&gt;one thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty-two&lt;/TD&gt;
&lt;TD&gt;three hundred and twenty-seven&lt;/TD&gt;
&lt;TD&gt;nine hundred and ten&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;three hundred and sixteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/3000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-two&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and forty&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;six hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;three hundred and sixty&lt;/TD&gt;
&lt;TD&gt;nine hundred and sixty-six&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;four hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-20/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;one thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;nine hundred and eight&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-seven&lt;/TD&gt;
&lt;TD&gt;one thousand five hundred and thirty&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty&lt;/TD&gt;
&lt;TD&gt;nine hundred and fifty&lt;/TD&gt;
&lt;TD&gt;five hundred and twenty&lt;/TD&gt;
&lt;TD&gt;one thousand and one hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-eight&lt;/TD&gt;
&lt;TD&gt;one thousand five hundred and thirty&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty&lt;/TD&gt;
&lt;TD&gt;nine hundred and sixty&lt;/TD&gt;
&lt;TD&gt;five hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;one thousand and one hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty-five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820656299.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820656299.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820716290.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 280px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820716290.jpg&quot; width=680 height=280&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820732431.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820732431.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820742454.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 4 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820742454.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN2 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12(C) series indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/193.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:15</pubDate>
           <comments></comments>
           <description>The GN19-12 (C) series indoor AC high voltage isolation switch is suitable for use in AC 50Hz, rated voltage 12kV and below power systems. It is equipped with a manual operating mechanism and is used as a switching device when there is voltage but no load.&lt;BR&gt;&lt;BR&gt;The performance of GN19-12 (C) series indoor AC high voltage isolation switch meets the standard requirements of &quot;AC high voltage isolation switch and grounding switch&quot;.&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101311529434.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 430px&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) Series Indoor AC High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200710/2007101311529434.jpg&quot; width=680 height=430&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;1. Altitude not exceeding 1000m;&lt;BR&gt;2. Surrounding air temperature: upper limit+40 ¡æ, lower limit -30 ¡æ;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. There is no fire, explosion hazard, serious pollution, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated voltage (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4S rated short-time withstand current (effective value) (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak withstand current (KA)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S400-12.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S1250-31.0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S400-12.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 274px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) series indoor AC high voltage isolation switch external dimensions&quot; align=absMiddle src=&quot;/uploadfiles/200610/2006102016260497.jpg&quot; width=274 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) installation dimensions&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162619363.jpg&quot; width=505 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;/P&gt;
&lt;P align=left&gt;Figure 1 GN19-12 series&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 304px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) characteristic curve&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162630475.jpg&quot; width=374 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=304&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) wiring diagram&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162643666.jpg&quot; width=505 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=left&gt;Figure 2 GN19-12C series Fig&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 212px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) series indoor AC high voltage isolation switch terminal diagram&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162654841.jpg&quot; width=500 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=212&gt;&lt;BR&gt;GN19-12(C)/630/400 GN19-12(C)/1000/1250&lt;/P&gt;
&lt;P align=left&gt;Figure 3: Dimensions of Wiring Terminals&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/1000/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.18&#215;28&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/1000/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;28&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1-12/3150A outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27666.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:25:16</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GW1-12/3150A Outdoor High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW18-27.5 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/24554.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:25:08</pubDate>
           <comments></comments>
           <description>The GW18-27.5 outdoor high-voltage isolation switch is suitable for use in electrified railway power systems with a rated frequency of 50Hz and a rated voltage of 27.5KV, and is used for voltage and no-load lines.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GW18-27.5 outdoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;data&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;twenty-seven point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=43&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=120&gt;
&lt;P align=center&gt;Rated insulation level&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=120&gt;
&lt;P align=center&gt;1-minute power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;to the ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;fracture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=120&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;
&lt;P align=center&gt;(Peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;to the ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;fracture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;two hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;Maximum operating voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;Peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;Short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kA-S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;25-2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=312 colSpan=3&gt;
&lt;P align=center&gt;weight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;one hundred and twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]BC-BJB Transformer neutral point gap protection device </title>
           <link>http://www.91way.com/info_en/24402.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:25:00</pubDate>
           <comments></comments>
           <description>The BC-BJB transformer neutral point gap protection device is specifically designed for the neutral points of 110KV, 220KV, and 330KV power transformers to achieve two different operating modes: grounded or ungrounded operation of the transformer neutral point.&lt;BR&gt;&lt;BR&gt;Technical specifications&lt;BR&gt;The technical data of BC-BJB type neutral grounding protection device is shown in the following table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Product Model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Transformer rating&lt;BR&gt;Constant voltage&lt;BR&gt;Kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Neutral point withstand voltage of transformer&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;disconnecting switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Zinc oxide lightning arrester&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;discharge gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;current transformer&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning full wave and cutoff withstand voltage&lt;BR&gt;kV&lt;BR&gt;(Peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1-minute power frequency&lt;BR&gt;kV&lt;BR&gt;(Effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Operation&lt;BR&gt;institution&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated&lt;BR&gt;voltage&lt;BR&gt;kV&lt;BR&gt;(Effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Continuous operation&lt;BR&gt;Line voltage&lt;BR&gt;kV&lt;BR&gt;(Effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Continuous operation&lt;BR&gt;Line voltage&lt;BR&gt;kV&lt;BR&gt;(Effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;8/20 ¦Ì s lightning&lt;BR&gt;Residual impulse current&lt;BR&gt;Voltage kV&lt;BR&gt;(Peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Power frequency discharge&lt;BR&gt;Voltage kV&lt;BR&gt;&#177;10%&lt;BR&gt;(Effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;type&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;transformation ratio&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;BC-BJB-110&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;CS8-5 (Hand)&lt;BR&gt;Dynamic or CJ6&lt;BR&gt;(Electric)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;epoxy resin&lt;BR&gt;Pouring full seal&lt;BR&gt;Closed pillar type&lt;BR&gt;10kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;100/5&lt;BR&gt;200/5&lt;BR&gt;300/5&lt;BR&gt;400/5&lt;BR&gt;500/5&lt;BR&gt;600/5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;BC-BJB-220&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. Suitable for indoor and outdoor use.&lt;BR&gt;2. Environmental temperature: not lower than -40 ¡æ, not higher than 60 ¡æ; Relative humidity: not exceeding 95% (25 ¡æ).&lt;BR&gt;3. The altitude should not exceed 3000m, and if it exceeds 3000m, it can be customized according to the actual situation.&lt;BR&gt;4. Areas with seismic intensity of 7 degrees or below; The maximum wind speed shall not exceed 35m/s.&lt;BR&gt;5. Grid frequency: 58-62Hz (60Hz system), 48-52Hz (50Hz system).&lt;BR&gt;6. The air in the installation site should not contain chemical corrosive gases and vapors, and there should be no explosive dust.&lt;BR&gt;&lt;BR&gt;Installation requirements&lt;BR&gt;1. The equipment can be lifted using the four mounting holes on the base, and the lifting rope should not be tied to the porcelain column to prevent damage to the equipment.&lt;BR&gt;2. The channel steel bracket for fixing the operating mechanism and the steel pipe from the operating mechanism to the conductive rod shaft of the isolation switch are not within the scope of supply of this device. All are made on site by the installation unit, and the length and size are determined on site.&lt;BR&gt;3. The equipment should be reliably grounded.&lt;BR&gt;4. The appearance and dimensions of the product shall be subject to the actual supply.&lt;BR&gt;5. The installation of the isolation switch can refer to the installation instructions for the GW8 or GW13 series neutral point isolation switch in the attachment.&lt;BR&gt;&lt;BR&gt;Instructions for Use&lt;BR&gt;1. The neutral point current transformer of the transformer is generally installed on the transformer outlet bushing and is not included in this device. The wiring diagram of this device is shown in the figure.&lt;BR&gt;When placing an order, the rated voltage of the transformer, the transformation ratio of the current transformer, the rated current of the isolation switch, the form of the operating mechanism, and the rated voltage of the zinc oxide lightning arrester should be informed. When not specifically specified, delivery will be made according to the technical data standard configuration in this manual.&lt;BR&gt;3. The secondary side of the current transformer has two secondary stages of 0.5/10P. For measurement and protection purposes. When not in use, it should be short circuited.&lt;BR&gt;4. The cross-sectional area and type of the wire connected to the neutral point of the transformer are determined by the user based on the actual current.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5-12/17.5 series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/18998.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:51</pubDate>
           <comments></comments>
           <description>GW5-12/17.5 series outdoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-20 series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/17423.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:43</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GW4-20 series outdoor high-voltage isolation switch is a maintenance free outdoor AC high-voltage isolation switch with light operating torque, manufactured in accordance with GB1985-89 &quot;AC High Voltage Isolation Switches and Grounding Switches&quot; and the specific requirements of electrified railways. Rated current: 200, 400, 630, 1250A. Suitable for use in power systems with a frequency of 50Hz and a rated voltage of 20KV, as a time division circuit with voltage and no load, and also for use in railway automatic block signaling devices. And it can be used at a single level. The anti fouling isolation switch can meet the requirements of users in heavily polluted areas and effectively solve the problem of pollution flashover that occurs during the operation of the isolation switch.&lt;BR&gt;The GW4-20 (G) TQ (D) (A) (B) series light operating torque maintenance free outdoor AC high-voltage isolation switch is a new generation of outdoor products suitable for railway self closing, through power supply remote control systems and railway station power supply systems. Equipped with CX-1 electric mechanism, it can easily interface with remote control systems to achieve remote control, remote signaling, and remote sensing.&lt;BR&gt;This series of products includes the following varieties:&lt;BR&gt;There are three types of grounding switches: ungrounded, single grounded, and double grounded.&lt;BR&gt;Classified by usage area: ordinary type, stain resistant type, high source type.&lt;BR&gt;This series of products meets the requirements of national standards and IEC standards. This series of products has good earthquake resistance and can meet the requirement of a seismic intensity of 9 degrees (horizontal acceleration of 4.9m/S2 and vertical acceleration of 2.45m/s2).&lt;BR&gt;product structure&lt;BR&gt;The GW4-20 series AC high voltage isolation switch consists of three single-phase components, which have a double column structure and are mainly composed of bottom and pillar insulation and conductive parts. The first phase has two insulated pillars installed on the bearing seats at both ends of the base, connected by cross connecting rods, and can rotate horizontally. The conductive switch is divided into two halves and fixed on the pillar insulator respectively, with the contact point between the two ceramic pillars.&lt;BR&gt;When the operating mechanism is activated, it drives one post of the insulator to rotate 90 degrees, and the other insulating post also rotates 90 degrees simultaneously due to the transmission of the connecting rod, so the switch blade opens and closes in the same direction. To ensure the correct operation sequence between the isolation switch and the grounding switch, a mechanical interlocking device is installed on the product or mechanism to ensure the sequential action of main opening ground closing ground opening main closing.&lt;BR&gt;GW4-20TQ (A) (B) type matching mechanism: CX-1 electric motor mechanism or CS11-1, CS11 (G), CS8-6D manual mechanism&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201109/20110916093300244.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 604px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GW4-20 Series Outdoor High Voltage Isolation Switch&quot; src=&quot;/upload2011/201109/20110916093300244.jpg&quot; width=604 height=320&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-27.5T(D)(W) Outdoor AC High Voltage Isolation Switch for Electrified Railway </title>
           <link>http://www.91way.com/info_en/17422.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Purpose:&lt;BR&gt;GW4-27.5T (D) (W) outdoor AC high voltage isolation switch for electrified railways is an outdoor high voltage electrical equipment with a frequency of 50HZ, used for switching AC 27.5kV contact network high voltage lines under voltage and no-load conditions, as well as for electrically isolating high-voltage busbars, circuit breakers and other electrical equipment under maintenance from live high voltage lines. It can also be used to separate and combine very small capacitor currents and inductor currents.&lt;BR&gt;2¡¢ Environmental conditions for use&lt;BR&gt;1. Altitude not exceeding 1000m; 2000m&lt;BR&gt;2. Environmental temperature: upper limit+40 ¡æ, lower limit -30 ¡æ;&lt;BR&gt;3. Wind speed not exceeding 35m/s;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. Insulator pollution level: Anti pollution type is Class III heavy pollution (salt density 0.3 milligrams per square centimeter);&lt;BR&gt;6. Installation location: Outdoor concrete single pole pole.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916091825131.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 611px; HEIGHT: 410px&quot; border=0 hspace=0 alt=&quot;Technical Specification Table for GW4-27.5T (D) (W) Outdoor AC High Voltage Isolation Switch for Electrified Railway&quot; src=&quot;/upload2011/201109/20110916091825131.jpg&quot; width=611 height=410&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;4¡¢ Structure&lt;BR&gt;The GW4-27.5T (D) (W) type outdoor AC high voltage isolation switch for electrified railways has reliable performance, simple structure, flexible installation method, easy maintenance, wide applicability, and strong versatility.&lt;BR&gt;The GW4-27.5T outdoor isolation switch is a high-voltage electrical device composed of a single pole isolation switch, and is also a basic unit derived from other structures. It is referred to as a common isolation switch below.&lt;BR&gt;W4-27.5T (D) outdoor isolation switch is made by adding a grounding knife to a regular isolation switch, which is divided into two types: one-time operation type and double operation type, hereinafter referred to as grounding type isolation switch.&lt;BR&gt;The GW4-27.5T (D) W outdoor isolation switch is a modification of the ordinary rod type post insulator into an anti fouling rod type post insulator based on the ordinary (grounding) isolation switch, and is suitable for heavily polluted or high-altitude areas.&lt;BR&gt;1. Isolation switch structure&lt;BR&gt;The single pole isolation switch is fixed on the same chassis by two rod type post insulators, and is a double column horizontal rotary structure. The external structure is shown in Figure 1.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916091900397.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 599px; HEIGHT: 552px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of outdoor AC high voltage isolation switch for GW4-27.5T (D) (W) electrified railway&quot; src=&quot;/upload2011/201109/20110916091900397.jpg&quot; width=599 height=552&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Each pole isolation switch consists of a base, an insulating pillar, and a conductive part.&lt;BR&gt;Each pole isolation switch has two insulation pillars fixed on the bearings at both ends of the base (Figure 2), connected by connecting rods. Each insulation pillar can rotate horizontally at a 90 &#176; angle, and is equipped with a conductive terminal block (Figure 3) and left and right contacts (Figure 4). The left and right contacts make contact between two insulated pillars through a conductive tube.&lt;BR&gt;The conductive terminal block is divided into two types based on its structure: hard connection type (Figure 3a) and connection type (Figure 3b), which are determined according to the user's ordering requirements.&lt;BR&gt;The material of the conductive circuit components in the main circuit is copper, and when the current level is 630A, the surface of the conductive components is tin plated; When the current level is above 1600A, the surface of conductive components is silver plated.&lt;BR&gt;The middle contact is a &quot;handshake&quot; structure, which adopts patented technology for pressing the contact finger blade gasket. It is a high-pressure, self-cleaning type, and the contact pressure of the contact finger remains constant for a long time. The contact finger spring has no current passing through, and it operates safely and reliably for a long time.&lt;BR&gt;The structural types, bases, post insulators, and other components of products with different current specifications are the same, except for slight differences in the main electrical circuit&lt;BR&gt;&lt;BR&gt;The base part is shown in Figure 2&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916091945142.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 599px; HEIGHT: 857px&quot; border=0 hspace=0 alt=&quot;Installation diagram of outdoor AC high voltage isolation switch base for GW4-27.5T (D) (W) electrified railway&quot; src=&quot;/upload2011/201109/20110916091945142.jpg&quot; width=599 height=857&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201109/20110916091957773.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 599px; HEIGHT: 1009px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of outdoor AC high voltage isolation switch for GW4-27.5T (D) (W) electrified railway&quot; src=&quot;/upload2011/201109/20110916091957773.jpg&quot; width=599 height=1009&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;1. Mechanical interlocking between single grounding secondary operation isolation switch and grounding switch blade&lt;BR&gt;The mechanical interlocking between the single grounding secondary operation isolation switch and the grounding switch blade is achieved through the interlocking panel on the CS8-6D manual mechanism.&lt;BR&gt;2. Structure of manual mechanism&lt;BR&gt;This series of isolating switches is equipped with two manual mechanisms: CS11 (ungrounded and single grounded one-time operation transmission type) and CS8-6D (single grounded secondary operation transmission type).&lt;BR&gt;CS11 (see Figure 6) and CS8-6D manual mechanisms (see Figure 7) have a horizontal rotation handle with a rotation angle of 90 &#176;.&lt;BR&gt;4. Structure of CX-6 electric mechanism&lt;BR&gt;The structure of the CX-6 electric mechanism can be found in its user and maintenance manual&lt;BR&gt;&lt;BR&gt;5¡¢ Principle of Action&lt;BR&gt;The opening and closing actions of this series of isolating switches are basically the same. When linking, the single pole isolation switch needs to be connected separately according to installation diagram 8 or diagram 9.&lt;BR&gt;1. Operating principle of isolation switch&lt;BR&gt;(1) Without grounding switch type&lt;BR&gt;The operating mechanism of the isolation switch is connected to the active stage of the isolation switch through a connecting tube. The main shaft of the mechanism rotates 90 degrees, which drives the insulation support of the active stage to rotate 90 degrees. At the same time, the connecting rod drives the insulation support on the other side to rotate in the opposite direction, achieving the opening and closing action. With the help of the connecting rod, each single pole switch can be connected into a bipolar or three pole linkage isolation switch. It is usually manufactured as a single pole and used as a single pole.&lt;BR&gt;(2) One time operation type with grounding switch blade&lt;BR&gt;The structure of the grounded knife switch is based on the above switch structure, with an additional operation of the grounding transmission mechanism It ensures that when the main switch starts to open, the grounding switch starts to rotate accordingly; When the main switch is turned to the disconnection terminal position, the grounding switch also reaches the grounding terminal position at the same time The opening and closing actions of the main switch and the grounding switch are completed in one go&lt;BR&gt;(3) Secondary operation type with grounding switch blade&lt;BR&gt;This structure uses two handles to operate the main blade and the grounding switch blade respectively A interlocking device is installed between the two operating handles to prevent accidental operation and ensure that the operation is carried out according to the prescribed procedure (main opening ground closing ground opening main closing).&lt;BR&gt;2. Working principle of grounding switch&lt;BR&gt;The handle of the operating mechanism rotates horizontally by 90 degrees, and the grounding switch is driven to rotate through the connecting rod to achieve the opening and closing actions of the grounding switch.&lt;BR&gt;3. The auxiliary switch in the operating mechanism is connected to the main shaft of the mechanism, and when the opening and closing actions are performed, the corresponding contacts are cut off or closed, and corresponding opening and closing signals are issued.&lt;BR&gt;&lt;BR&gt;6¡¢ Installation and adjustment&lt;BR&gt;1. The installation and adjustment of isolation switches should meet the following requirements:&lt;BR&gt;(1) When equipped with a manual mechanism, operators with general physical strength should be able to independently perform opening and closing operations with flexible movements.&lt;BR&gt;(2) The closing synchronicity value of the bipolar or three pole linkage of the isolation switch is not greater than 6mm;.&lt;BR&gt;(3) The resistance of each phase circuit of the isolation switch should meet the requirements in Table 3&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916092125577.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 69px&quot; border=0 hspace=0 alt=&quot;GW4-27.5T (D) (W) outdoor AC high voltage isolation switch circuit resistance meter for electrified railways&quot; src=&quot;/upload2011/201109/20110916092125577.jpg&quot; width=580 height=69&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;2. Installation and adjustment of isolation switch&lt;BR&gt;(1) Fix each pole isolation switch base on a horizontal foundation according to installation diagram 8 or 9,&lt;BR&gt;(2) Place the operating mechanism under the rotating spindle on the active side of the isolation switch. When the main body of the isolation switch and the operating spindle of the mechanism isolation switch are in the closed position, use a toothed clamp to connect and tighten the water and gas pipe. When the main and driven insulation pillars are not synchronized, adjust the positive and negative teeth screws between the poles to achieve opening and closing.&lt;BR&gt;(3) The installation and adjustment of the bipolar or interlocking closing synchronization of the isolation switch, under the condition that the two terminals bear normal busbar tension, adjust the length of the positive and negative tooth connecting rods between the phases to meet the above requirements.&lt;BR&gt;(4) When the isolation switch is in the closed position, all contact points on the contacts should be in contact. The tightening degree of the M8 screw on the contacts should be the best state when the spring washer is just flattened and the contact fingers can swing.&lt;BR&gt;3. Installation and adjustment of grounding switch with secondary operation type&lt;BR&gt;(1) When both the grounding switch and the main shaft of the mechanism are in the closed position, use a toothed clamp to connect and tighten the water and gas pipe.&lt;BR&gt;(2) When the grounding switch is in the closed position, the contact position of the contact can be adjusted by placing the grounding contact on the conductive tube. When the closed position is correct, tighten the fastening nut.&lt;BR&gt;7¡¢ Acceptance and storage&lt;BR&gt;1. After the product arrives at the destination, the user should place it in a dry and ventilated place, not invert it, and conduct acceptance as soon as possible according to the following items:&lt;BR&gt;(1) Firstly, check the outer surface of the packaging box for any damage or abnormalities. After the external inspection is completed, open the packaging box and take out the attached documents.&lt;BR&gt;(2) Check whether the documents attached to the product are complete (including packing list, product certificate, installation and use instructions, etc.)&lt;BR&gt;(3) Remove the product and accessories (be careful not to damage the insulation pillar porcelain bottle), and verify.&lt;BR&gt;(4) Check the appearance of the product for any damage or abnormal phenomena.&lt;BR&gt;2. After receiving the product experience, regardless of whether it is installed and used immediately, the following items should be stored and kept:&lt;BR&gt;(1) The friction rotating parts of the isolation switch must be wiped clean and coated with acid free Vaseline for protection.&lt;BR&gt;(2) When products are stored in the warehouse for a long time, they should be inspected regularly (no more than six months each time). If rust is found, the rust layer should be removed and rust inhibitor should be applied.&lt;BR&gt;8¡¢ Instructions for use&lt;BR&gt;1. Before putting into operation, a comprehensive inspection should be conducted to confirm that there are no errors before putting it into operation.&lt;BR&gt;(1) Whether the dimensions of each part of the isolation switch meet the requirements.&lt;BR&gt;(2) The bolts of each connecting part should be securely fastened, especially the connection with the busbar.&lt;BR&gt;(3) All contact points on the contact should be in full contact&lt;BR&gt;(4) After being put into operation, the following matters should be noted:&lt;BR&gt;(5) In general, isolation switches must be opened and closed only after the line load is cut off.&lt;BR&gt;(6) The isolation switch with a secondary operation type grounding switch must be fully opened before the grounding switch can be closed; On the contrary, the closing operation of the isolation switch can only be carried out after the grounding switch is completely opened.&lt;BR&gt;2. Isolation switches must be regularly maintained and inspected, and the following precautions should be taken during maintenance:&lt;BR&gt;(1) Check if the isolation switch porcelain bottle is damaged and if the adhesive is loose.&lt;BR&gt;(2) Whether the contact points on the contacts are in good contact when the isolation switch is in the closed position; Check if the spring on the contact is deformed, if the tension has changed, and measure the circuit resistance.&lt;BR&gt;(3) Whether the auxiliary switches and other components in the organization are well insulated.&lt;BR&gt;(4) Is the grounding condition good.&lt;BR&gt;(5) Whether the rotating parts are flexible during operation and there should be no jamming phenomenon.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-35GW(D)/1600A-4000A High current isolation switch </title>
           <link>http://www.91way.com/info_en/17421.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GW4-40.5D (W) type outdoor high current high voltage isolation switch is an outdoor high voltage electrical equipment with a frequency of 50HZ, rated currents of 1600A, 2000A, 2500A, 4000A, used for switching high voltage lines under voltage and no-load conditions, as well as for electrically isolating high voltage busbars, circuit breakers and other electrical equipment under maintenance from live high voltage lines. It can also be used to separate and combine very small capacitor currents and inductor currents.&lt;BR&gt;&lt;BR&gt;GW4-35GW (D)/1600A-4000A high current isolation switch operating environmental conditions&lt;BR&gt;1. Altitude not exceeding 1000m;&lt;BR&gt;2. Environmental temperature: upper limit+40 ¡æ, lower limit -40 ¡æ;&lt;BR&gt;3. Wind speed not exceeding 40.5m/s;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. Insulator pollution level: Ordinary level is level 0; Anti fouling type is Grade II;&lt;BR&gt;6. The installation site should be free of flammable substances, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;The main technical parameters of GW4-35GW (D)/1600A-4000A high current isolation switch are shown in Table 1&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916091047239.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 403px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GW4-35GW (D)/1600A-4000A high current isolation switch&quot; src=&quot;/upload2011/201109/20110916091047239.jpg&quot; width=535 height=403&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201109/20110916090942265.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 534px; HEIGHT: 1790px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW4-35GW (D)/1600A-4000A high current isolation switch&quot; src=&quot;/upload2011/201109/20110916090942265.jpg&quot; width=534 height=1790&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Each pole is composed of three independent monopoles, each consisting of a base, insulating pillars, and conductive parts.&lt;BR&gt;Each pole has two insulation pillars fixed on the bushings at both ends of the base, connected by connecting rods. Each insulation pillar can rotate horizontally at a 90 &#176; angle, and is equipped with a conductive terminal block and left and right contacts (Figure 4b). The left and right contacts are in contact between the two insulation pillars through a conductive tube.&lt;BR&gt;1. Structure of grounding switch&lt;BR&gt;The static contact of the grounding switch is fixed on the conductive pipe of the isolation switch, and the moving contact is installed at the end of the grounding switch steel pipe on the base.&lt;BR&gt;2. Mechanical interlocking of isolation switch and grounding switch&lt;BR&gt;The mechanical interlocking between the isolating switch and the grounding switch is achieved through the interlocking panel on the CS8-6D manual mechanism.&lt;BR&gt;3. Structure of manual mechanism&lt;BR&gt;Manual mechanisms are divided into two types: CS11 ungrounded mechanism (Figure 5) and CS8-6D single grounded mechanism (Figure 6). The operating handle is horizontally rotated, with a rotation angle of 90 &#176;; CS14G mechanism installation dimensions and&lt;BR&gt;&lt;BR&gt;The CS11 mechanism is the same, only with a rotation angle of 180 &#176;, used for the main knife manual mechanism of the double grounding isolation switch.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5,GW4-72.5GW(D) series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/17420.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:18</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GW4-72.5GW (D) type outdoor AC high voltage isolation relationship double column three-phase AC 50Hz outdoor high voltage switchgear is used in power systems with voltages ranging from 10 to 220KV, for the purpose of closing circuits with voltage and no load, and for the electrical isolation of high-voltage busbars, circuit breakers and other electrical equipment under maintenance from live high-voltage lines. The anti fouling isolation switch can meet the requirements of users in heavily polluted areas and effectively solve the problem of pollution flashover that occurs during the operation of the isolation switch. The combination of GW4 series and CJ2 series electric operating mechanisms is particularly suitable for the needs of long-distance separation and connection in the fields of power systems and electrified railways.&lt;BR&gt;&lt;BR&gt;The GW5, GW4-72.5GW (D) series outdoor high-voltage isolating switches have the following varieties:&lt;BR&gt;1) Divided by the presence or absence of a grounding switch: ungrounded, single grounded (left and right grounded), and double grounded;&lt;BR&gt;2) Grounding switches are classified into types I, II, and III based on their ability to withstand short-circuit currents;&lt;BR&gt;3) Divided by usage area: ordinary type, anti fouling type, anti fouling type, and high-altitude type.&lt;BR&gt;This series of products meets the requirements of national standards and IEC standards, with good seismic resistance and the ability to meet the requirement of a seismic intensity of 9 degrees.&lt;BR&gt;Structural characteristics:&lt;BR&gt;The GW4 outdoor AC high voltage isolation switch is a three-phase double column, horizontal opening structure, mainly composed of a base, post insulators, and conductive parts. Two post insulators are installed on the bearings at both ends of the base, connected by connecting rods, and can rotate horizontally. The main switch blade is divided into left and right parts, which are respectively fixed on the two post insulators, and the contact part of the contact is between the two posts. When the operating mechanism is activated, it drives one of the connected insulators to rotate 90 degrees, and the other insulating pillar also rotates 90 degrees simultaneously due to the transmission of the connecting rod, so the left and right brake blades open and close in the same direction. The product is divided into two types: ordinary type and stain resistant type, among which the stain resistant type can be used in Class III polluted areas.&lt;BR&gt;2. According to user needs, the grounding knife equipped with the product is assembled on the rotating shaft of the base. The static contact is installed on the main electrical system pole, and there is a mechanical interlock between the grounding switch and the isolation switch, which can ensure the sequential action of the main switch to ground and the ground switch to main switch. (Power distribution mechanism can be used as needed)&lt;BR&gt;3. The isolation switch is made in a single pole form and can form a three pole linkage through inter pole connections. This switch can also be used single pole as needed.&lt;BR&gt;When the isolating switch is equipped with CS17 manual mechanism, one non grounded mechanism is equipped, two single grounded mechanisms are equipped, and three double grounded mechanisms are equipped. At the same time, CS14-G and CJ6 (electric mechanism) are also available for users to choose from.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GW5, GW4-72.5GW (D) series outdoor high-voltage isolation switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916090718488.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 534px; HEIGHT: 488px&quot; border=0 hspace=0 alt=&quot;GW5, GW4-72.5GW (D) series outdoor high-voltage isolation switch technical parameter table&quot; src=&quot;/upload2011/201109/20110916090718488.jpg&quot; width=534 height=488&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Terms of Use&lt;BR&gt;1. The altitude shall not exceed 1000m, and the plateau type shall not exceed 4000m;&lt;BR&gt;2. Environmental temperature: -40 ¡æ to+40 ¡æ;&lt;BR&gt;3. Wind speed not exceeding 35m/s;&lt;BR&gt;4. Earthquake intensity: 8 degrees;&lt;BR&gt;5. Ice thickness: ¡Ü 10mm;&lt;BR&gt;6. Anti pollution products are suitable for polluted areas;&lt;BR&gt;7. Not suitable for places with flammable substances, explosion hazards, chemical corrosion, and severe vibrations. Explanation: When the above environmental conditions cannot meet the usage requirements, it shall be resolved through negotiation between the user and the manufacturer.&lt;BR&gt;5¡¢ Ordering Notice&lt;BR&gt;Please specify when placing an order:&lt;BR&gt;(1) Product model and name;&lt;BR&gt;(2) Rated voltage, rated current, dynamic and thermal stability current;&lt;BR&gt;(3) Terminal tension;&lt;BR&gt;(4) Outdoor insulator creepage distance;&lt;BR&gt;(5) Grounding switch types (Type I, Type II, Type III) and grounding methods (single grounding, double grounding);&lt;BR&gt;(6) The model of the operating mechanism, the number of auxiliary switch poles, whether the electric magnetic lock is mounted with a coding lock, the voltage of the electric motor and the control voltage of the motor mechanism;&lt;BR&gt;(7) GW4 type fracture opening distance and long short contacts.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-126GW(D) Outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/17419.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;I. Overview&lt;BR&gt;GW4-126GW (D) outdoor AC high voltage isolation relationship double column three-phase AC 50Hz outdoor high voltage switchgear is used in power systems with a voltage of 110KV, for the purpose of closing circuits with and without voltage load, and for the electrical isolation of high-voltage busbars, circuit breakers and other electrical equipment under maintenance from live high-voltage lines. The anti fouling isolation switch can meet the requirements of users in heavily polluted areas and effectively solve the problem of pollution flashover that occurs during the operation of the isolation switch.&lt;BR&gt;The combination of GW4 series and CJ5, CJ6, CJ2, CJ11A series electric operating mechanisms is particularly suitable for the needs of long-distance separation and combination in the fields of power systems and electrified railways.&lt;BR&gt;&lt;BR&gt;GW4-126GW (D) outdoor high-voltage isolation switches have the following varieties:&lt;BR&gt;1) Divided by the presence or absence of a grounding switch: ungrounded, single grounded (left and right grounded), and double grounded;&lt;BR&gt;2) Grounding switches are classified into types I, II, and III based on their ability to withstand short-circuit currents;&lt;BR&gt;3) Divided by usage area: ordinary type, anti fouling type, anti fouling type, and high-altitude type.&lt;BR&gt;This series of products meets the requirements of national standards and IEC standards, with good seismic resistance and the ability to meet the requirement of a seismic intensity of 9 degrees.&lt;BR&gt;&lt;BR&gt;Note: GW4-126 isolating switches are produced according to the following requirements:&lt;BR&gt;1. Improve the non welding type of hoop connection;&lt;BR&gt;2. Level 3 pollution prevention, creepage distance ¡Ý 3150mm;&lt;BR&gt;3. Equipped with alternating hot-dip galvanized horizontal connecting rods, with a pole spacing of 2m;&lt;BR&gt;4. Hot dip galvanizing of components;&lt;BR&gt;5. Conductive copper tube flexible connection type;&lt;BR&gt;6. The middle contact of the conductive part is a self operated contact finger, and there is no current passing through the spring;&lt;BR&gt;7. The rotating part is equipped with a self-lubricating sleeve.&lt;BR&gt;&lt;BR&gt;2¡¢ Main technical parameters&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916085502365.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 601px; HEIGHT: 467px&quot; border=0 hspace=0 alt=&quot;GW4-126GW (D) Outdoor High Voltage Isolation Switch Technical Parameters Table&quot; src=&quot;/upload2011/201109/20110916085502365.jpg&quot; width=601 height=467&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;(Note: Single grounding is divided into two types: left grounding and right grounding. Generally, right grounding is supplied.)&lt;/P&gt;
&lt;P align=left&gt;3¡¢ Usage conditions&lt;BR&gt;1. The altitude shall not exceed 1000m, and the plateau type shall not exceed 4000m;&lt;BR&gt;2. Environmental temperature: -40 ¡æ to+40 ¡æ;&lt;BR&gt;3. Wind speed not exceeding 35m/s;&lt;BR&gt;4. Earthquake intensity: 8 degrees;&lt;BR&gt;5. Ice thickness: ¡Ü 10mm;&lt;BR&gt;6. Anti pollution products are suitable for polluted areas;&lt;BR&gt;7. Not suitable for places with flammable substances, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;Explanation: When the above environmental conditions cannot meet the usage requirements, it shall be resolved through negotiation between the user and the manufacturer.&lt;BR&gt;4¡¢ Structure&lt;BR&gt;The GW4 series isolating switch has reliable performance, simple structure, flexible installation method, easy maintenance, wide applicability, and strong versatility. If equipped with a transmission box, the opening and closing operation is more flexible, lightweight, accurate and reliable; When an electromagnetic lock is attached, it can effectively achieve electrical interlocking between the isolation switch, grounding switch, and circuit breaker to prevent misoperation.&lt;BR&gt;The GW4-126 outdoor isolation switch is a three-phase high-voltage electrical appliance composed of three independent single pole isolation switches, and is also a basic unit derived from other structures. It is referred to as a common isolation switch below.&lt;BR&gt;The GW4-126D outdoor isolation switch is made by adding a grounding knife to the ordinary isolation switch, which is divided into single grounding and double grounding types, hereinafter referred to as the grounding type isolation switch.&lt;BR&gt;The GW4-126 (DW) outdoor isolation switch is made by replacing the ordinary rod type post insulator with an anti fouling rod type post insulator based on the ordinary (grounding) isolation switch, and is suitable for polluted areas.&lt;BR&gt;1. Isolation switch structure&lt;BR&gt;This isolation switch is a double column horizontal rotary structure, as shown in Figure 1 for its external structure. &lt;BR clear=all&gt;Each set of isolation switches consists of three independent single poles, each consisting of a base, an insulating pillar, and a conductive part. Each pole isolation switch has two insulation pillars fixed on the bearing seats at both ends of the base (Figure 2), connected by connecting rods. Each insulation pillar can rotate horizontally at a 90 &#176; angle, and is equipped with a soft connection conductive terminal block (Figure 3) and left and right contacts (Figure 4). The left and right contacts make contact between two insulated pillars through a conductive tube. The isolation switch bearing seat is shown in Figure 2&lt;BR&gt;The conductive terminal block for the soft connection of the isolation switch is shown in Figure 3&lt;BR&gt;The left and right contacts of the isolation switch are shown in Figure 4&lt;BR&gt;The material of the conductive circuit components in the main circuit is copper, and when the current level is 630A, the surface of the conductive components is tin plated; When the current level is above 1250A, the contact surface of the conductive component is silver plated.&lt;BR&gt;The middle contact is a &quot;handshake&quot; structure, which adopts patented technology for pressing the contact finger blade gasket. It is a high-pressure, self-cleaning type, and the contact pressure of the contact finger remains constant for a long time. The contact finger spring has no current passing through, and it operates safely and reliably for a long time.&lt;BR&gt;The structural types, bases, post insulators, and other components of products with different current specifications are the same, except for slight differences in the main electrical circuit&lt;BR&gt;2. Structure of grounding switch&lt;BR&gt;The static contact of the grounding switch is fixed on the conductive tube of the isolation switch, and the moving contact is installed at the end of the aluminum tube of the grounding switch on the base.&lt;BR&gt;3. Mechanical interlocking of isolation switch and grounding switch&lt;BR&gt;The mechanical interlocking between the isolating switch and the grounding switch is achieved through an interlocking disc. When the isolating switch is in the closed position, the fan-shaped interlocking disc of the grounding switch rotating shaft restricts the closing of the grounding switch.&lt;BR&gt;When the grounding switch is in the closed position, the grounding switch related locking plate is inserted into the fan-shaped interlocking plate of the isolating switch, preventing the isolating switch from closing.&lt;BR&gt;4. Structure of the operating mechanism&lt;BR&gt;The isolation switch can be equipped with CS14G manual mechanism (Figure 5) or CJ5, CJ6 electric mechanism and CJ12A-G maintenance free electric mechanism. The grounding switch can be equipped with CS14G manual mechanism, and its operating handle is horizontally rotating with a rotation angle of 180 &#176;.&lt;BR&gt;CJ5, CJ6 electric mechanisms and CJ12A-G maintenance free electric mechanisms can be found in their respective manuals.&lt;BR&gt;CS14G manual mechanism is shown in Figure 5&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110916085555884.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 583px; HEIGHT: 1336px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW4-126GW (D) outdoor high-voltage isolation switch&quot; src=&quot;/upload2011/201109/20110916085555884.jpg&quot; width=583 height=1336&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201109/20110916085608589.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 596px; HEIGHT: 1103px&quot; border=0 hspace=0 alt=&quot;Outline drawing of GW4-126GW (D) outdoor high-voltage isolation switch&quot; src=&quot;/upload2011/201109/20110916085608589.jpg&quot; width=596 height=1103&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201109/20110916085620114.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 596px; HEIGHT: 1060px&quot; border=0 hspace=0 alt=&quot;GW4-126GW (D) Outdoor High Voltage Isolation Switch Structure Diagram&quot; src=&quot;/upload2011/201109/20110916085620114.jpg&quot; width=596 height=1060&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4C-252D(G)252kV Outdoor high-voltage AC isolation switch </title>
           <link>http://www.91way.com/info_en/17301.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:24:01</pubDate>
           <comments></comments>
           <description>GW4C-252D (G) type outdoor high-voltage transmission equipment with three-phase AC frequency of 50Hz is used to disconnect or connect high-voltage lines under no-load conditions, in order to switch high-voltage lines, change operating modes, and safely isolate high-voltage electrical equipment such as busbars and circuit breakers for maintenance.&lt;BR&gt;This product is a double column horizontal fracture center opening type, which can be equipped with JW10-252 grounding switches on one or both sides. The isolation switch adopts SRCJ1 type motor operating mechanism three pole linkage operation; The grounding switch adopts SRCS1 type manual operation mechanism with three pole linkage operation.&lt;BR&gt;&lt;BR&gt;The GW4C-252D (G) 252kV outdoor high-voltage AC isolation switch complies with standards such as GB1985-2004 &quot;High Voltage AC Isolation Switches and Grounding Switches&quot;, GB11022-1999, DL/T593-2006 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;, DL/T486-2000 &quot;Technical Conditions for Ordering AC Isolation Switches and Grounding Switches&quot;, and meets the relevant regulations on ordering high-voltage isolation switches issued by State Grid Corporation of China for improvement. And through seismic resistance calculation analysis with a seismic intensity of 9 degrees.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;THEAD&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;Unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;Parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/THEAD&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=84&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;SUP&gt;£¨1£©&lt;/SUP&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV&gt;a) 1-minute power frequency withstand voltage (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=225 colSpan=2&gt;
&lt;DIV align=center&gt;The shortest distance during the closing process of the grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and ninety-one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV align=center&gt;b) Rated lightning impulse withstand voltage (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;1600&amp;nbsp;&amp;nbsp;2000&amp;nbsp; 2500&amp;nbsp; 3150&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;40&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 50&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;100&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Rated terminal mechanical load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal and vertical loads&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal lateral load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;vertical force&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;1000&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Isolation switch busbar conversion current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;300V, 1600A, 100 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Grounding switch induced current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;1) Electromagnetic induction current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;160/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨80/2£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;2) Static induced current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;10/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨3/12£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;3) Opening and closing times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Isolation switch low current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;capacitive current &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Inductive current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;creepage distance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;6300&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 7812&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Human operated mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCS1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Electric motor operating mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCJ1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Motor voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Opening and closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;12&#177;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;output angle &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;unipolar weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;not grounded&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;four hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Single grounding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;four hundred and thirty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Double grounding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;four hundred and fifty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=604 colSpan=6&gt;
&lt;DIV&gt;Note: (1) This product belongs to the high-altitude (G) type, and the insulation test is assessed at an altitude of 2000 meters, with a correction factor of k=1.13; If the insulation level is set at 395 kV, it can be used in areas with an altitude of 2800 meters.&lt;/DIV&gt;
&lt;DIV&gt;(2) The parameters are specified as Class B values in DL/T486-2000, and arc ignition devices must be installed; The values in parentheses are specified for Class B in GB1985-2004.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW7B-252D(G)252kV Outdoor high-voltage AC isolation switch </title>
           <link>http://www.91way.com/info_en/17300.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:53</pubDate>
           <comments></comments>
           <description>GW7B-252D (G) type outdoor high-voltage transmission equipment with a three-phase AC frequency of 50Hz is used to disconnect or connect high-voltage lines under no-load conditions, in order to switch high-voltage lines, change operating modes, and safely isolate high-voltage electrical equipment such as busbars and circuit breakers for maintenance.&lt;BR&gt;This product is a three column horizontal fracture switch flip type, which can be equipped with JW10-252 grounding switches on one or both sides. The isolation switch adopts SRCJ2 type motor operating mechanism three pole linkage operation; The grounding switch adopts SRCS1 type manual operation mechanism with three pole linkage operation.&lt;BR&gt;&lt;BR&gt;The GW7B-252D (G) 252kV outdoor high-voltage AC isolation switch complies with standards such as GB1985-2004 &quot;High Voltage AC Isolation Switches and Grounding Switches&quot;, GB11022-1999, DL/T593-2006 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;, DL/T486-2000 &quot;Technical Conditions for Ordering AC Isolation Switches and Grounding Switches&quot;, and meets the relevant regulations on ordering high-voltage isolation switches issued by State Grid Corporation of China for improvement. And through seismic resistance calculation analysis with a seismic intensity of 9 degrees.&lt;BR&gt;&lt;BR&gt;The GW7B-252D (G) 252kV outdoor high-voltage AC isolation switch adopts a flip type, with a two-step action of the conductive tube. When closing, the conductive tube first rotates about 70 &#176; on the horizontal plane. When the two end contacts enter the static contact seat and are blocked, the flipping mechanism drives the conductive tube to rotate about 45 &#176;. The moving contact is in reliable contact with the contact finger, with low operating force and no impact force on the fixed insulators at both ends. The main contact has self cleaning ability.&lt;BR&gt;The U-shaped contact finger in the static contact is fixed at one end on the contact seat, forming a fixed connection and ensuring reliable conductivity; The other end generates contact pressure on the moving contact through an external pressure spring and the elastic force of the contact finger itself, and automatically increases the clamping force when the short-circuit current passes through. The touch finger spring is made of stainless steel material and has an insulating spacer, which prevents rusting and prevents flow diversion.&lt;BR&gt;The static contact is equipped with a hook plate, which locks the moving contact after closing. Even under strong winds, vibrations, and electric forces, the contact will not detach. The arcing contacts on the dynamic and static contacts enable the isolation switch to have good performance in switching busbar current and switching capacitors and inductors with low current.&lt;BR&gt;The grounding switch is a one-step action type, with a simple structure and easy maintenance. It effectively uses electric force to clamp the contacts and keep the grounding knife in the closed position. It has strong ability to withstand short-circuit currents and high parameters for opening and closing induced currents.&lt;BR&gt;The conductive tube is made of high-strength, high conductivity, and corrosion-resistant aluminum material. The two end moving contacts are assembled and easy to replace.&lt;BR&gt;The conductive tube flipping mechanism is enclosed, rainproof, dust-proof, and corrosion-resistant, and the flipping action is accurate and reliable.&lt;BR&gt;The base is made of square steel pipes and bent plates welded together, with high strength and good rigidity. The surface is hot-dip galvanized and has strong anti-corrosion ability. All black metal components (including M10 and above fasteners) are treated with hot-dip galvanizing.&lt;BR&gt;The rotating parts of the isolation switch are designed according to maintenance free requirements. The rotating seat is a fully sealed structure, which prevents water vapor, dust, and harmful gases from entering. The lubricating grease inside the bearing does not lose or solidify.&lt;BR&gt;Stainless steel pin shafts, self-lubricating bearings, and stainless steel joint bearings are used at each rotating friction point.&lt;BR&gt;The transmission connecting rod adopts assembly type, and on-site installation does not require cutting and welding. The connecting rod adopts hot-dip galvanized seamless steel pipe.&lt;BR&gt;The mechanism interlocking between the main blade and the ground blade adopts a cam sliding plate structure, with direct action and reliable interlocking.&lt;BR&gt;The operating mechanism box is made of stainless steel plate riveting, which does not require welding and has a good appearance. The electric mechanism adopts a hollow gearbox and nylon gears, with smooth and noise free operation. It uses foreign brand electrical components, which work reliably and have complete locking functions.&lt;BR&gt;The human resources organization utilizes the intermediate relay installed in the box to achieve electromagnetic lock function, which is reliable in interlocking and overcomes the disadvantages of rust, corrosion, and malfunction of outdoor electromagnetic locks commonly used in China.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;THEAD&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;Unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;Parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/THEAD&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=84&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;SUP&gt;£¨1£©&lt;/SUP&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV&gt;a) 1-minute power frequency withstand voltage (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=225 colSpan=2&gt;
&lt;DIV align=center&gt;The shortest distance during the closing process of the grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and ninety-one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV align=center&gt;b) Rated lightning impulse withstand voltage (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;2000&amp;nbsp; 2500&amp;nbsp; 3150&amp;nbsp; 4000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Rated terminal mechanical load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal and vertical loads&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal lateral load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;vertical force&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Isolation switch busbar conversion current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;300V, 1600A, 100 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Grounding switch induced current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;1) Electromagnetic induction current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;160/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨80/2£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;2) Static induced current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;10/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨3/12£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;3) Opening and closing times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Isolation switch low current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;capacitive current &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Inductive current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;creepage distance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;6300&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 7812&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Human operated mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCS1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Electric motor operating mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCJ2&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Motor voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Opening and closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;14&#177;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;output angle &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;180&#176;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;unipolar weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;not grounded&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Single grounding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Double grounding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=604 colSpan=6&gt;
&lt;DIV&gt;Note: (1) This product belongs to the high-altitude (G) type, and the insulation test is assessed at an altitude of 2000 meters, with a correction factor of k=1.13; If the insulation level is set at 395 kV, it can be used in areas with an altitude of 2800 meters.&lt;/DIV&gt;
&lt;DIV&gt;(2) The parameters are specified as Class B values in DL/T486-2000, and arc ignition devices must be installed; The values in parentheses are specified for Class B in GB1985-2004.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW22B-252D(G)252kV Outdoor high-voltage AC isolation switch </title>
           <link>http://www.91way.com/info_en/17299.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:43</pubDate>
           <comments></comments>
           <description>GW22B-252D (G) type outdoor high-voltage transmission equipment with a three-phase AC frequency of 50Hz is used to disconnect or connect high-voltage lines under no-load conditions, in order to switch high-voltage lines, change operating modes, and safely isolate high-voltage electrical equipment such as busbars and circuit breakers for maintenance.&lt;BR&gt;This product is a single column vertical fracture deflection type and can be equipped with JW10-252 grounding switch. The isolation switch adopts SRCJ3 type motor operating mechanism three pole linkage operation; The grounding switch adopts SRCS1 type manual operation mechanism with three pole linkage operation.&lt;BR&gt;&lt;BR&gt;The GW22B-252D (G) 252kV outdoor high-voltage AC isolation switch complies with standards such as GB1985-2004 &quot;High Voltage AC Isolation Switches and Grounding Switches&quot;, GB11022-1999, DL/T593-2006 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;, DL/T486-2000 &quot;Technical Conditions for Ordering AC Isolation Switches and Grounding Switches&quot;, and meets the relevant regulations on ordering high-voltage isolation switches issued by State Grid Corporation of China for improvement. And through seismic resistance calculation analysis with a seismic intensity of 9 degrees.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;THEAD&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;Unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;Parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/THEAD&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=84&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;SUP&gt;£¨1£©&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV&gt;a) 1-minute power frequency withstand voltage (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=225 colSpan=2&gt;
&lt;DIV align=center&gt;b) Rated lightning impulse withstand voltage (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=184&gt;
&lt;DIV&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;1600&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 2000&amp;nbsp; 2500&amp;nbsp; 3150&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;40&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 50&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV&gt;100&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Rated terminal mechanical load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal and vertical loads&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal lateral load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;vertical force&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;Isolation switch busbar conversion current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;300V, 1600A, 100 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Grounding switch induced current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;1) Electromagnetic induction current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;160/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨80/2£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;2) Static induced current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;10/15&lt;SUP&gt;£¨2£©&amp;nbsp;&lt;/SUP&gt;£¨3/12£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;3) Opening and closing times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Isolation switch low current opening and closing capability&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;capacitive current &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Inductive current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Rated contact area&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Longitudinal displacement of supporting wire&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;©L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;150/200 (hard wire/soft wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Horizontal total offset&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;©L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;150/500 (hard wire/soft wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;vertical offset&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;©L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;150/250 (hard wire/soft wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=309 colSpan=3&gt;
&lt;DIV&gt;creepage distance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;6300&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 7812&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Human operated mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCS1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;Electric motor operating mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;SRCJ3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Motor voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;Opening and closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;10&#177;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;output angle &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;135&#176;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132 colSpan=2&gt;
&lt;DIV align=center&gt;unipolar weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;not grounded&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=177&gt;
&lt;DIV&gt;grounding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=244 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=604 colSpan=6&gt;
&lt;DIV&gt;Note: (1) This product belongs to the high-altitude (G) type, and the insulation test is assessed at an altitude of 2000 meters, with a correction factor of k=1.13; If the insulation level is set at 395 kV, it can be used in areas with an altitude of 2800 meters.&lt;/DIV&gt;
&lt;DIV&gt;(2) The parameters are specified as Class B values in DL/T486-2000, and arc ignition devices must be installed; The values in parentheses are specified for Class B in GB1985-2004.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]JW10-252(G)252kV Outdoor high-voltage AC isolation switch </title>
           <link>http://www.91way.com/info_en/17298.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:35</pubDate>
           <comments></comments>
           <description>JW10-252 (G) type high-voltage AC grounding switch is an independently installed high-voltage outdoor grounding device. Suitable for 220kV power lines with AC 50Hz, it is used to release static charges from the inspected lines and equipment, and to implement electrical safety grounding for high-voltage equipment such as busbars and circuit breakers during maintenance, so that there are obvious grounding opening and closing signs in the line, ensuring the personal safety of maintenance personnel during power outages. Usually, in places where a single column vertical disconnect switch is used, it is used to ground the upper busbar.&lt;BR&gt;&lt;BR&gt;The JW10-252 (G) 252kV outdoor high-voltage AC isolation switch is a one-step action type, using SRCS1 manual operation mechanism or SRCJ3 electric motor operation mechanism for three pole linkage operation.&lt;BR&gt;&lt;BR&gt;The JW10-252 (G) 252kV outdoor high-voltage AC isolation switch complies with standards such as GB1985-2004 &quot;High Voltage AC Isolation Switches and Grounding Switches&quot;, GB11022-1999, DL/T593-2006 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;, DL/T486-2000 &quot;Technical Conditions for Ordering AC Isolation Switches and Grounding Switches&quot;, and meets the relevant regulations on ordering high-voltage isolation switches issued by State Grid Corporation of China for improvement.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;THEAD&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV align=center&gt;Project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;Parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/THEAD&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=106 colSpan=3&gt;
&lt;DIV align=center&gt;Rated insulation level (1)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=192&gt;
&lt;DIV&gt;a) 1-minute power frequency withstand voltage (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=192&gt;
&lt;DIV&gt;b) Rated lightning impulse withstand voltage (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;one thousand and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Rated terminal mechanical load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;Horizontal and vertical loads&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;one thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;Horizontal lateral load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;vertical force&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Grounding switch opening and closing induced current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;a) Inductive current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;160/15£¨2£©£¨80/2£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;b) Capacitive current (current/voltage)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;A/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;10/15£¨2£©£¨3/12£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=204 colSpan=2&gt;
&lt;DIV&gt;c) Operate multiple times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;DIV&gt;creepage distance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;6300 7812&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=66&gt;
&lt;DIV align=center&gt;Human operated mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;SRCS1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=66&gt;
&lt;DIV align=center&gt;Electric motor operating mechanism&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;SRCJ3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;Motor voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;AC380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;Control circuit voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;AC220¡¢AC380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;Opening and closing time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;10&#177;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;output angle &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;135&#176;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=66&gt;
&lt;DIV align=center&gt;unipolar weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=232 colSpan=3&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=538 colSpan=6&gt;
&lt;DIV&gt;Note: (1) This product belongs to the high-altitude (G) type, and the insulation test is assessed at an altitude of 2000 meters, with a correction factor of k=1.13; If the insulation level is set at 395 kV, it can be used in areas with an altitude of 2800 meters.&lt;/DIV&gt;
&lt;DIV&gt;(2) The parameters are specified as Class B values in DL/T486-2000, and arc ignition devices must be installed; The values in parentheses are specified for Class B in GB1985-2004&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1-12/400A-1250A Three phase linkage outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16404.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:27</pubDate>
           <comments></comments>
           <description>GW1-12/400A-1250A three-phase linkage outdoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW6A-220D(W) type high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/15881.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:18</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GW6A-220 D (W) outdoor high-voltage isolation switch is a single column three-phase AC 50Hz outdoor high-voltage transmission equipment, used to disconnect or connect high-voltage lines under no-current conditions, and to achieve safe electrical isolation during maintenance of busbars, circuit breakers and other equipment.&lt;BR&gt;This product has a symmetrical scissor structure, which forms a vertical insulation fracture after opening. The opening and closing states are clear and intuitive, which is very conducive to inspection and suitable for soft and hard busbars.&lt;BR&gt;&lt;BR&gt;GW6A-220D (W) high-voltage isolation switch is usually used as a busbar isolation switch in power distribution equipment, with the advantage of small footprint. Its land saving effect is most significant in distribution equipment with double busbar and bypass connection.&lt;BR&gt;GW6A-220 D (W) outdoor high-voltage isolation switch can be equipped with a Type II grounding switch for grounding the lower end of the fracture (lower lead). The ability of Type II grounding switch to withstand short-circuit current is the same as that of isolation switch. This isolation switch and the attached grounding switch are each equipped with independent operating mechanisms, and mechanical interlocking devices are installed on the isolation switch to ensure the correct operation sequence between the isolation switch and the grounding switch.&lt;BR&gt;&lt;BR&gt;There are two types of operating mechanisms used with this product:&lt;BR&gt;CJ2-XG or other models of electric mechanical operating mechanisms, used for operating isolation switches.&lt;BR&gt;CS9-G hand operated mechanism, used for operating grounding switches.&lt;BR&gt;This isolation switch and grounding switch are both three-phase mechanical linkage.&lt;BR&gt;The product features: GW6A-220 D (W) type isolation switch is an improved product based on GW6-220 D (W) type. The improved isolation switch has added oil injection devices in the rotating and transmission parts, which will not cause rusting during long-term operation. Ensuring the reliability of product operation and reducing daily maintenance and upkeep.&lt;BR&gt;&lt;BR&gt;Technical parameters of GW6A-220D (W) high-voltage isolation switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Product Model&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;GW6A-220 D£¨W£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Rated voltage kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Maximum voltage kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;two hundred and fifty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Rated current A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=4&gt;
&lt;P align=center&gt;Dynamic stability current (peak value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=4&gt;
&lt;P align=center&gt;3-second thermal stability current (effective value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=66&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P&gt;1-minute withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=94&gt;
&lt;P align=center&gt;Ground kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;460£¨395£¬360£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=94&gt;
&lt;P align=center&gt;Fracture kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;530£¨460£¬415£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top rowSpan=2 colSpan=3&gt;
&lt;P align=left&gt;Lightning impulse withstand voltage (full wave)&lt;/P&gt;
&lt;P align=center&gt;1.2£­1.5/40£­50¦Ìs&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=94&gt;
&lt;P align=center&gt;Ground kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;1050£¨950£¬850£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=94&gt;
&lt;P align=center&gt;Fracture kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;1200£¨1050£¬950£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Rated static tension of terminal N&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;
&lt;P align=center&gt;three thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Creepage distance mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;3740£¬5500£¬6300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=4&gt;
&lt;P align=center&gt;Cut capacitor current A&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=5&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=4&gt;
&lt;P align=center&gt;Isolation switch opening and closing time S&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=4&gt;
&lt;P align=center&gt;six&lt;SPAN&gt;&lt;U&gt;£«&lt;/U&gt;one&lt;/P&gt;&lt;/SPAN&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=197&gt;
&lt;P align=center&gt;eight&lt;SPAN&gt;&lt;U&gt;£«&lt;/U&gt;one&lt;/P&gt;&lt;/SPAN&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=66&gt;
&lt;P align=center&gt;grounding switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=3&gt;
&lt;P align=center&gt;Dynamic stability current (peak value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=3&gt;
&lt;P&gt;Thermal stability current (effective value) kA-S&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;40-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;50-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=197&gt;
&lt;P align=center&gt;50-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;unipolar weight&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=2&gt;
&lt;P align=center&gt;Non grounded kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=3&gt;
&lt;P align=center&gt;five hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=2&gt;
&lt;P align=center&gt;seven hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=2&gt;
&lt;P align=center&gt;Grounding kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=3&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top colSpan=2&gt;
&lt;P align=center&gt;seven hundred and seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P align=center&gt;According to the national standard pressure resistance standard in parentheses, it can be used for altitudes of 2000m and 2900m&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Product Structure Description:&lt;BR&gt;The GW6A-220 D (W) type isolating switch consists of a base, supporting insulator, operating insulator, switch head (composed of moving contact, conductive switch blade, and transmission mechanism), and static contact (composed of static contact rod, shielding ring, and conductive connector). The isolating switch with a grounding switch is fixed on the base of the isolating switch, and the interlocking device between the grounding switch and the isolating switch is also located on the base of the grounding switch. The improved GW6A-220 D (W) type isolation switch has its moving contact and conductive switch located outside the transmission mechanism box.&lt;BR&gt;&lt;BR&gt;Ordering Notice:&lt;BR&gt;1. Model, specification, and quantity of isolation switches:&lt;BR&gt;a¡¢ Rated current b, whether there is a grounding switch c, creepage distance d, indicating opening distance of 2.2m or 2.55m e, terminal tension and long and short contacts&lt;BR&gt;2. Model, specification, and quantity of the accompanying operating mechanism:&lt;BR&gt;a. Control voltage and number of auxiliary switch contacts for CJ2-XG motor operating mechanism&lt;BR&gt;b. Does the CS9-G manual mechanism require an electromagnetic lock (DSW1 type) and specify the control voltage. To install a coded lock, please indicate.&lt;BR&gt;3. Do you need YY-III type contact pressure measuring instrument.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW32-12/40.5/72.5 High voltage outdoor isolation switch </title>
           <link>http://www.91way.com/info_en/15880.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:09</pubDate>
           <comments></comments>
           <description>The GW32 series AC high-voltage isolation switch is an outdoor high-voltage transmission equipment with three-phase AC and a frequency of 50Hz. It is used to disconnect or connect high-voltage lines under no-load conditions, change the operation mode of distribution equipment and busbars, and achieve safe electrical isolation during maintenance of busbars, circuit breakers and other electrical equipment.&lt;BR&gt;&lt;BR&gt;The GW32-12/40.5/72.5 high-voltage outdoor isolation switch is a double column horizontal fracture vertical opening structure, and its fracture is clearly visible after opening, which is conducive to inspection. The product has the advantages of small footprint, small inter phase distance, simple structure, easy operation, and simple appearance. The conductive switch adopts a two-step action, that is, after the moving contact comes into contact with the static contact seat, the moving contact flips 40 &#176;, so that the contact pressure between the moving and static contacts is stable and reliable, achieving close contact with the static contact finger. The assembly of the static contact seat adopts an internal hidden external pressure structure, and the contact finger spring will not produce any diversion. The rotating part bearings adopt double sealed and self-lubricating bearings to maintain good lubrication and flexible rotation, and generally require minimal maintenance. This product can be supplied from above ground level.&lt;BR&gt;This product complies with GB1985-2004 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot;, and is equivalent to IEC60129 (1984) &quot;AC High Voltage Isolating Switches and Grounding Switches&quot; and GB/T11022-1999 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;.&lt;BR&gt;This product is equipped with rod-shaped pillar composite insulators (which can also be equipped with porcelain insulators, classified into three level and four level anti fouling types according to the pollution conditions of use). According to the grounding method, it can be divided into four forms: &quot;ungrounded&quot;, &quot;front grounded (with grounding switch on the auxiliary contact side)&quot;, &quot;rear grounded (with grounding switch on the main contact side)&quot;, and &quot;double grounded&quot;.&lt;BR&gt;&lt;BR&gt;Product classification&lt;BR&gt;1¡¢ GW32£­12¡¢ The 40.5 and 72.5 outdoor isolation switches are composed of three independent single-phase isolation switches, an integral channel steel crossbeam, and two columns. They are the basic unit of the derived grounding switch.&lt;BR&gt;2. Install one grounding switch for each phase of the front grounding switch (with a grounding switch on the side of the auxiliary contact finger seat).&lt;BR&gt;3. Install one grounding switch for each phase of the rear grounding switch (with a grounding switch on the main contact finger seat side).&lt;BR&gt;4. Two grounding switches are installed for each phase of the double grounding switch.&lt;BR&gt;5. The installation method is horizontal installation.&lt;BR&gt;6. According to the operation mode, it can be divided into three pole linkage or single pole operation.&lt;BR&gt;7. According to the type of insulator material used, ceramic insulators and composite insulators are classified.&lt;BR&gt;8. According to the working environment, it is divided into Level III anti fouling and Level IV anti fouling.&lt;BR&gt;9. According to the operating mechanism, the main knife (isolation switch) has two types of operating mechanisms: electric and manual, while the ground knife (grounding switch) only has a manual operating mechanism. When the main knife is manually operated, use the CS17-G hand operated mechanism or the CS9-G hand operated mechanism, and use the CS17-G hand operated mechanism for the ground knife.&lt;BR&gt;&lt;BR&gt;Technical parameters of the product&lt;BR&gt;1. The main technical parameters of the isolation switch are shown in Table 1&lt;BR&gt;Table 1&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=39&gt;
&lt;P align=center&gt;part&lt;/P&gt;
&lt;P align=center&gt;class&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Forehead&lt;/P&gt;
&lt;P align=center&gt;fixed&lt;/P&gt;
&lt;P align=center&gt;electricity&lt;/P&gt;
&lt;P align=center&gt;press&lt;/P&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;rated&lt;/P&gt;
&lt;P align=center&gt;current&lt;/P&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;disconnecting switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;grounding switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;grounding&lt;/P&gt;
&lt;P align=center&gt;kind&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;Associated institutions&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current kA (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current kA/4s (effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current kA (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current kA/4s (effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;isolation&lt;/P&gt;
&lt;P&gt;switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;grounding&lt;/P&gt;
&lt;P align=center&gt;switch&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=39&gt;
&lt;P align=center&gt;prevent&lt;/P&gt;
&lt;P align=center&gt;filth&lt;/P&gt;
&lt;P align=center&gt;type&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;GW32¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;
&lt;P align=center&gt;seventy-two point five&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P&gt;not grounded&lt;/P&gt;
&lt;P&gt;Left single grounding&lt;/P&gt;
&lt;P&gt;Right single grounding&lt;/P&gt;
&lt;P&gt;Double grounding&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;hand crank&lt;/P&gt;
&lt;P align=center&gt;Institution or Handheld Institution&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P&gt;electric actuator&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;CS17-G&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: The maximum rated current for 12kV is 1250A&lt;BR&gt;3¡¢ Ordering Information&lt;BR&gt;When placing an order, please specify the product model, rated voltage, rated current, grounding type (front grounding, rear grounding, double grounding, ungrounded), anti fouling level, and special requirements for manual and electric mechanisms.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW7A series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/15749.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:23:01</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GW7A series isolation switch is a three-phase AC 50Hz outdoor high-voltage electrical appliance with a three column horizontal double break structure. Used for switching high-voltage lines under no-current conditions and electrically isolating high-voltage busbars, circuit breakers, and other electrical appliances under maintenance from voltage carrying lines.&lt;BR&gt;&lt;BR&gt;The GW7A series outdoor high-voltage isolation switch is operated by a CJ6-XG motor mechanism, the attached Type I grounding switch is operated by a CS17-G manual operating mechanism, and the Type II grounding switch is operated by a CS9-G manual operating mechanism. The grounding switch (Type II) of GW7A-500D is operated by CJ6-XG electric motor mechanism or CS9-G manual mechanism. CS17-G manual mechanism operation. 145 and 220KV are three-phase linkage; 330 and 500KV are single-phase operations, and when equipped with an electric mechanism, three-phase electrical linkage can be achieved through a control box.&lt;BR&gt;&lt;BR&gt;The GW7A series outdoor high-voltage isolation switch can be equipped with grounding switches on one or both sides. The switch body is equipped with a mechanical interlocking device, which can ensure the correctness of the operation sequence of the isolation switch and the grounding switch. GW7A-220D (W) passed the three-phase dynamic thermal stability test at KEMA in the Netherlands.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=588 colSpan=9&gt;
&lt;P align=center&gt;Project parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated voltage kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=308 colSpan=4&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Maximum working voltage kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=308 colSpan=4&gt;
&lt;P align=center&gt;two hundred and fifty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated current A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated thermal stability current (effective value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;40/40/50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated thermal stability time S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated dynamic stability current (peak value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;100/100/125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=49&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=224 colSpan=3&gt;
&lt;P align=center&gt;1-minute power frequency voltage (effective value) kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=56 colSpan=2&gt;
&lt;P align=center&gt;to the ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;395(460)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;four hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56 colSpan=2&gt;
&lt;P align=center&gt;fracture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;460(530)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;five hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=49&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=224 colSpan=3&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak) kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=56 colSpan=2&gt;
&lt;P align=center&gt;to the ground&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;950(1050)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;one thousand and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56 colSpan=2&gt;
&lt;P align=center&gt;fracture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;1050(1200)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;one thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Rated terminal mechanical load N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;1000 or 1500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Disconnect capacitor current A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280 colSpan=5&gt;
&lt;P align=center&gt;Electric opening and closing time S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;6.4&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=49&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=231 colSpan=4&gt;
&lt;P align=center&gt;Creepage distance mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ordinary&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;three thousand seven hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;three thousand seven hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;anti-fouling&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;five thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=154 colSpan=2&gt;
&lt;P align=center&gt;five thousand three hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=49&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=42&gt;
&lt;P align=center&gt;grounding switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=189 colSpan=3&gt;
&lt;P align=center&gt;Dynamic stability current (peak value) KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type II&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;100/125&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=189 colSpan=3&gt;
&lt;P align=center&gt;Thermal stability current (effective value) KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;10(1S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;10(1S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;10(1S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type II&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;20(3S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;31.5(3S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;40/50(3S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;50(3S)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=49&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=42&gt;
&lt;P align=center&gt;Supporting organization&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=238 colSpan=4&gt;
&lt;P align=center&gt;disconnecting switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CJ&lt;SUB&gt;two&lt;/SUB&gt;-G or CS17-G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CJ&lt;SUB&gt;two&lt;/SUB&gt;-G&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CJ&lt;SUB&gt;two&lt;/SUB&gt;-XG&lt;/P&gt;
&lt;P align=center&gt;CJ&lt;SUB&gt;two&lt;/SUB&gt;-GIV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CJ&lt;SUB&gt;two&lt;/SUB&gt;-G¢ò&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=189 colSpan=3&gt;
&lt;P align=center&gt;grounding switch&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=231 colSpan=3&gt;
&lt;P align=center&gt;CS17-G or CS17-II&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Type II&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=231 colSpan=3&gt;
&lt;P align=center&gt;CS&lt;SUB&gt;nine&lt;/SUB&gt;¡ªG&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;CS&lt;SUB&gt;nine&lt;/SUB&gt;¡ªG&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=49&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=210 colSpan=2&gt;
&lt;P align=center&gt;Weight kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=70 colSpan=3&gt;
&lt;P align=center&gt;not grounded&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;five hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;five hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;six hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70 colSpan=3&gt;
&lt;P align=center&gt;Single grounding&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;six hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;six hundred and seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;seven hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one thousand five hundred and seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70 colSpan=3&gt;
&lt;P align=center&gt;Double grounding&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;seven hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;seven hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;seven hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;one thousand six hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]FZW33-12/15 Outdoor vacuum load isolation switch (electric, manual) </title>
           <link>http://www.91way.com/info_en/8350.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:52</pubDate>
           <comments></comments>
           <description>FZW33-12/15 Outdoor Vacuum Load Isolation Switch (Electric, Manual)&lt;BR&gt;&lt;BR&gt;Rated voltage (kV): 12; fifteen&lt;BR&gt;Rated current (A): 630&lt;BR&gt;Rated frequency (Hz): 50 1min&lt;BR&gt;Power frequency withstand voltage: Vacuum fracture (kV): 42 phase to phase, ground (kV): 42&lt;BR&gt;Isolation fracture (kV): 50 lightning impulse withstand voltage: phase to phase, ground (kV): 75&lt;BR&gt;Isolation fracture (kV): 85&lt;BR&gt;Rated short-circuit closing current (kA): 50&lt;BR&gt;Rated short-time withstand current (kA): 20 (4S)&lt;BR&gt;Rated peak withstand current (kA): 50&lt;BR&gt;Mechanical lifespan (times): 10000&lt;BR&gt;&lt;BR&gt;FZW33-12/15 Outdoor Vacuum Load Isolation Switch (Electric, Manual)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]HGW1-12 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/8212.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:44</pubDate>
           <comments></comments>
           <description>The HGW1-12 outdoor high-voltage isolation switch is suitable for use in power systems with an AC frequency of 50Hz and a rated working voltage of 10KV. It is used as an outdoor switchgear for breaking and closing power supply under voltage and no-load conditions&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW23-126/252(D)(W) type high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/7836.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:36</pubDate>
           <comments></comments>
           <description>Introduction to the Structure of GW23-126/252 (D) (W) High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;The complete set of isolation switch consists of GW23-126/252 (D) (W) type isolation switch body, CJ7 electric mechanism, manual operation mechanism, transmission accessories, etc.&lt;BR&gt;The single pole isolation switch is divided into two parts: the moving side and the stationary side. The moving side is composed of three parts: the main switch blade, the porcelain bottle, and the base.&lt;BR&gt;The base part consists of a steel frame, an operating lever, a connecting rod, and a grounding knife base and knife rod. For the operating pole, there is also a mechanism interlocking component between the main switch and the grounding switch.&lt;BR&gt;Each pole has two columns of porcelain bottles on the moving side, one column is used to support the main blade, and the other column is used to transmit operating torque, also known as &quot;operating porcelain bottles&quot;.&lt;BR&gt;The main blade first converts the horizontal rotation of the operating porcelain bottle into vertical rotation of the double crank arm through a pair of bevel gears, and then drives the seat to rotate through the double connecting rod, achieving the two major motion processes of folding and clamping. After opening, a visible horizontal fracture is formed.&lt;BR&gt;The static side part mainly consists of three components: static side base, static side porcelain bottle, and static contact rod. Non grounded steel frames are of small size, and corresponding accessories are added when there is a grounding switch. The static side insulator is the same as the dynamic side. The static contact rod is a silver plated copper rod with an outer diameter of ¦µ 40, which is fixed to the terminal block.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;GW23-126 (D) (W) type isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;21%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;GW23£­126(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV&gt;two hundred and eighty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV&gt;six hundred and twenty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;GW23£­126(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GW23-252 (D) (W) type isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;GW23£­252(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;8%&quot;&gt;
&lt;DIV&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;8%&quot;&gt;
&lt;DIV&gt;six hundred and six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one thousand and fifty&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;6%&quot;&gt;
&lt;DIV&gt;one thousand two hundred and fifty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;GW23£­252(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;GW23£­252(D)£¨W£©/2500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;50/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;50/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;GW23£­252(D)£¨W£©/3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;50/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;50/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009102914390273.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 453px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Model Description of GW23-126/252 (D) (W) High Voltage Isolation Switch&quot; src=&quot;/upload2009/200910/2009102914390273.jpg&quot; width=453 height=270&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW22-126/252(D)(W) type high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/7835.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:27</pubDate>
           <comments></comments>
           <description>Introduction to GW22-126/252 (D) (W) High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;The complete set of isolation switch consists of GW22-126/252 (D) (W) type isolation switch body, CJ7 electric mechanism, manual operation mechanism, transmission accessories, etc. This product can be placed directly below the busbar, with its static contacts suspended on the overhead busbar. After the product is opened, it forms a vertical insulation fracture. Especially in substations with &quot;double busbar with bypass busbar&quot;, the saving of floor space is particularly significant.&lt;BR&gt;The isolation switch is a single column vertical fracture folding type. The base is equipped with post insulators and operating insulators, as well as connecting rods and toggle arms. In addition, it is also equipped with mechanical interlocking components between the main switch blade and the grounding switch blade (only on the operating pole). The base has installation holes that can be directly installed on cement or steel frame foundations.&lt;BR&gt;Clockwise rotation of the insulator can drive the main switch blade to extend and close, while counterclockwise rotation can cause it to close and fold, in the open state, forming a visible vertical fracture.&lt;BR&gt;When the static contact fixed on the busbar deviates from the ideal position due to natural external disturbances such as strong winds, thermal expansion and contraction of the busbar, or ice cover, the switch itself can still easily achieve normal opening and closing during operation. Secondly, during installation and commissioning, even if the switch error is large, it can still ensure good completion of normal opening and closing. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;GW22-126 (D) (W) type isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;23%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW22£­126(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;31.5/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;six hundred and twenty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW22£­126(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GW22-252 (D) (W) type isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Rated]&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;GW22£­252(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;8%&quot;&gt;
&lt;DIV&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV&gt;four hundred and sixty&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;six hundred and six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV&gt;one thousand and fifty&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;one thousand two hundred and fifty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;GW22£­252(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;50/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;GW22£­252(D)£¨W£©/2500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;50/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;GW22£­252(D)£¨W£©/3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;50/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091029143547917.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 469px; HEIGHT: 282px&quot; border=0 hspace=0 alt=&quot;Model Description of GW22-126/252 (D) (W) High Voltage Isolation Switch&quot; src=&quot;/upload2009/200910/20091029143547917.jpg&quot; width=469 height=282&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4A-40.5 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7834.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:19</pubDate>
           <comments></comments>
           <description>GW4A-0.5 series high-voltage isolation switch structure&lt;BR&gt;&lt;BR&gt;The complete set of isolation switch consists of GW4A-40.5 (D) (W) type isolation switch body, CS14G type manual operating mechanism, transmission accessories, etc. It can also be equipped with CJ6 type and other electric mechanisms.&lt;BR&gt;The isolation switch adopts a double column center opening and contact turning structure, which has the ability of self-cleaning contacts and improves contact reliability.&lt;BR&gt;The conductive circuit uses rectangular copper pipes, which increase the heat dissipation area by 40% compared to the original circular pipes, greatly reducing the temperature rise of the main electrical part.&lt;BR&gt;The touch finger is made of a new type of material with high strength, high conductivity, and high elasticity. By relying on the elastic force of the contact finger itself to clamp the contact, the vicious cycle of reduced clamping force, increased contact resistance, and intensified contact heating caused by spring corrosion and thermal annealing is avoided. And the contact finger and the contact finger seat are fixed by bolts, which avoids the possibility of oil and dust entering their contact points and increasing the contact resistance. This conductive part structure has obtained a national utility model patent.&lt;BR&gt;The rotating part of the isolation switch is designed to be maintenance free. The rotating seat is designed with a sealed structure, which prevents water vapor, dust, and harmful gases from entering. This ensures that the bearings and molybdenum disulfide lithium based grease always work in a good environment, the bearings never rust, the grease cannot be lost, and it never dries. This prevents the operating torque of the isolation switch from increasing after long-term operation. Adopting a structure that combines stainless steel shaft pins with oil-free self-lubricating shaft supports; The steel components are hot-dip galvanized to ensure flexible, lightweight, reliable, and rust free operation of the isolation switch.&lt;BR&gt;The foot installation size of GW4A-0.5 grounding switch is exactly the same as that of GW4-40.5 isolating switch, and can directly replace GW4-40.5 isolating switch. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Main technical parameters of GW4A-10.5 series high-voltage isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;25%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;
&lt;DIV align=center&gt;resistance&lt;/DIV&gt;
&lt;DIV&gt;¦Ì¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak endurance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;lightning surge&lt;/DIV&gt;
&lt;DIV&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW4A£­40.5(D)£¨W£©/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;20/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;20/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;one hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;two hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW4A£­40.5(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW4A£­40.5(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW4A£­40.5(D)£¨W£©/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091029143038744.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 384px; HEIGHT: 203px&quot; border=0 hspace=0 alt=&quot;Model Description of GW4A-0.5 Series High Voltage Isolation Switch&quot; src=&quot;/upload2009/200910/20091029143038744.jpg&quot; width=384 height=203&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4A-126 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7833.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:10</pubDate>
           <comments></comments>
           <description>YJDX-75-6 Vibration Motor Structure&lt;BR&gt;&lt;BR&gt;The complete set of isolation switch consists of GW4A-126 (D) (W) type isolation switch body, CS14G or CS17G type manual operating mechanism, transmission accessories, etc. It can also be equipped with CJ6 type electric mechanism, etc.&lt;BR&gt;The isolation switch adopts a double column center opening and contact turning structure, which has the ability of self-cleaning contacts and improves contact reliability.&lt;BR&gt;The conductive circuit uses rectangular copper pipes, which increase the heat dissipation area by 40% compared to the original circular pipes, greatly reducing the temperature rise of the main electrical part.&lt;BR&gt;The touch finger is made of a new type of material with high strength, high conductivity, and high elasticity. By relying on the elastic force of the contact finger itself to clamp the contact, the vicious cycle of reduced clamping force, increased contact resistance, and intensified contact heating caused by spring corrosion and thermal annealing is avoided. And the contact finger and the contact finger seat are fixed by bolts, which avoids the possibility of oil and dust entering their contact points and increasing the contact resistance. This conductive part structure has obtained a national utility model patent.&lt;BR&gt;The rotating part of the isolation switch is designed to be maintenance free. The rotating seat is designed with a sealed structure, which prevents water vapor, dust, and harmful gases from entering, ensuring that the bearings and lithium molybdenum disulfide based grease always work in a good environment. The bearings never rust, the grease cannot be lost, and it never dries; The bearing seat is equipped with thrust ball bearings and radial ball bearings inside, which bear the gravity and horizontal force of the isolation switch through two special bearings, so that the operating torque of the isolation switch will not increase after long-term operation. Adopting a structure that combines stainless steel shaft pins with oil-free self-lubricating shaft supports; The steel components are hot-dip galvanized to ensure flexible, lightweight, reliable, and rust free operation of the isolation switch.&lt;BR&gt;The foot installation size of GW4A-126 grounding switch is exactly the same as that of GW4-126 isolating switch, and can directly replace GW4-126 isolating switch.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GW4A-126 series high-voltage isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;23%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;
&lt;DIV align=center&gt;resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;¦Ì¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW4£­126(D)£¨W£©/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;7%&quot;&gt;
&lt;DIV&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;20/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;20/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;two hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;5%&quot;&gt;
&lt;DIV&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW4£­126(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW4£­126(D)£¨W£©/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;GW4£­126(D)£¨W£©/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091029142736326.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 386px; HEIGHT: 203px&quot; border=0 hspace=0 alt=&quot;Model Description of GW4A-126 Series High Voltage Isolation Switch&quot; src=&quot;/upload2009/200910/20091029142736326.jpg&quot; width=386 height=203&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5A-40.5/126 series complete set of isolation switches </title>
           <link>http://www.91way.com/info_en/7832.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:22:02</pubDate>
           <comments></comments>
           <description>Introduction to the Structure of GW5A-40.5/126 Series Complete Isolation Switch&lt;BR&gt;The complete set of isolation switch consists of GW5A-126 (D) (W) type isolation switch body, CS17 or CS17G type manual operating mechanism, transmission accessories, etc. It can also be equipped with CJ6 type and other electric mechanisms.&lt;BR&gt;The isolation switch adopts a double column center opening and contact turning structure, which has the ability of self-cleaning contacts and improves contact reliability.&lt;BR&gt;The conductive circuit uses rectangular copper pipes, which increase the heat dissipation area by 40% compared to the original circular pipes, greatly reducing the temperature rise of the main electrical part.&lt;BR&gt;The touch finger is made of a new type of material with high strength, high conductivity, and high elasticity. By relying on the elastic force of the contact finger itself to clamp the contact, the vicious cycle of reduced clamping force, increased contact resistance, and intensified contact heating caused by spring corrosion and thermal annealing is avoided. And the contact finger and the contact finger seat are fixed by bolts, which avoids the possibility of oil and dust entering their contact points and increasing the contact resistance. This conductive part structure has obtained a national utility model patent.&lt;BR&gt;The rotating part of the isolation switch is designed to be maintenance free. The rotating seat is designed with a sealed structure, which prevents water vapor, dust, and harmful gases from entering. This ensures that the bearings and molybdenum disulfide lithium based grease always work in a good environment, the bearings never rust, the grease cannot be lost, and it never dries. This prevents the operating torque of the isolation switch from increasing after long-term operation. Adopting a structure that combines stainless steel shaft pins with oil-free self-lubricating shaft supports; The steel components are hot-dip galvanized to ensure flexible, lightweight, reliable, and rust free operation of the isolation switch.&lt;BR&gt;The mechanical interlocking between the main blade and the ground blade is directly installed on the main blade spindle and the ground blade spindle, without the need for a separate transmission box, reducing the workload of on-site installation and debugging.&lt;BR&gt;The foot installation size of GW5A-126 grounding switch is exactly the same as that of GW5-126 isolating switch, and can directly replace GW5-126 isolating switch.&lt;BR&gt;&lt;BR&gt;GW5A-40.5/126 series complete set of isolation switch technical parameters&lt;BR&gt;GW5A£­40.5&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;25%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;
&lt;DIV align=center&gt;resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;¦Ì¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;One minute frequency&lt;/DIV&gt;
&lt;DIV&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;Thunder shock&lt;/DIV&gt;
&lt;DIV&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­40.5(D)£¨W£©/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;20/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;20/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;ninety-five&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;one hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;one hundred and eighty-five&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;two hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­40.5(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­40.5(D)£¨W£©/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GW5A£­126&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;25%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;main circuit&lt;/DIV&gt;
&lt;DIV align=center&gt;resistance&lt;/DIV&gt;
&lt;DIV&gt;¦Ì¦¸&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated short-time tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot; colSpan=2&gt;
&lt;DIV align=center&gt;Rated peak tolerance&lt;/DIV&gt;
&lt;DIV align=center&gt;Current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV&gt;Withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; colSpan=2&gt;
&lt;DIV&gt;lightning surge&lt;/DIV&gt;
&lt;DIV&gt;Voltage withstand kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV&gt;Main electrical circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;to the ground&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­126(D)£¨W£©/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;20/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;20/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;two hundred and thirty&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;two hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;five hundred and fifty&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;5%&quot;&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­126(D)£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;31.5/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;31.5/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV&gt;GW5A£­126(D)£¨W£©/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW39-12 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/7051.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GW39-12 outdoor AC high voltage isolation switch is suitable for three-phase AC power systems with a frequency of 50Hz, and is used for opening and closing no-load lines.&lt;BR&gt;&lt;BR&gt;Product structural features:&lt;BR&gt;1. The product is a three-phase linkage type, with a rod-shaped structure for the moving contact and a horizontal opening form for the opening and closing action.&lt;BR&gt;2. The opening and closing transmission method uses the rotating intermediate insulator to drive the moving contact to achieve its horizontal displacement, which improves the reliability of its opening and closing.&lt;BR&gt;3. The switch adopts silicone rubber composite insulation for ground insulation, which improves the overall insulation level and anti pollution ability of the switch, and also enhances its resistance to mechanical impact.&lt;BR&gt;4. The contact pressure of the static contact is adjusted separately to ensure the balance of contact pressure between the moving and static contacts.&lt;BR&gt;5. The operating mechanism adopts dual protection of mechanical and electromagnetic locks, avoiding the occurrence of human errors in separation and closure.&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091020143244834.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 564px; HEIGHT: 351px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GW39-12 Outdoor High Voltage Isolation Switch&quot; src=&quot;/upload2009/200910/20091020143244834.jpg&quot; width=564 height=351&gt;&lt;/A&gt;&lt;BR&gt;GW39-12 Outdoor High Voltage Isolation Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1-10/15 Outdoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/5460.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;Model and specifications of GW1-10/15 outdoor AC high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200941584557738.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 120px&quot; border=0 hspace=0 alt=&quot;Model Description of GW1-10/15 Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200904/200941584557738.jpg&quot; width=650 height=120&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Basic Technical Parameters of GW1-10/15 Outdoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200941584610169.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 174px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GW1-10/15 Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200904/200941584610169.jpg&quot; width=650 height=174&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200941584648524.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 347px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW1-10/15 outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200904/200941584648524.jpg&quot; width=650 height=347&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;GW1-10/15 Outdoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW8-40.5/72.5/126 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/3630.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:36</pubDate>
           <comments></comments>
           <description>&lt;DIV&gt;The GW8-40.5/72.5/126 series high-voltage isolating switch is composed of a post insulator, an insulating porcelain bottle, and a conductive part. A static contact and a connecting plate for connecting the busbar are installed on the upper part of the post insulator. There is a metal base, an operating lever, and an operating insulator between the supporting insulator and the insulating porcelain bottle seat. The base is equipped with a knife switch, and the CS8-5 manual operating mechanism is connected to the knife switch through a connecting rod, an operating insulator, and a crank arm. It can also be equipped with a CJ6 electric mechanism.&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;Main technical parameters of GW8-40.5/72.5/126 series high-voltage isolating switch&lt;/DIV&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;Rated short-time&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;Rated peak value&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;pressure resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;GW8£­40.5£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40£®5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;8/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;GW8£­72.5£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;72£®5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;8/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;GW8£­126£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;DIV align=center&gt;8/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200805/2008519152036171.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 530px; HEIGHT: 243px&quot; border=0 hspace=0 alt=&quot;GW8-40.5/72.5/126 series high-voltage isolating switch model description&quot; src=&quot;/uploadfiles/200805/2008519152036171.jpg&quot; width=530 height=243&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/200872322648198.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 780px&quot; border=0 hspace=0 alt=&quot;GW8-40.5/72.5/126 series high-voltage isolation switch external dimensions and technical parameters table&quot; src=&quot;/uploadfiles/200807/200872322648198.jpg&quot; width=680 height=780&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200807/200872322712718.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW8-40.5/72.5/126 series high-voltage isolation switch&quot; src=&quot;/uploadfiles/200807/200872322712718.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW13-40.5/72.5/126 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/3629.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:28</pubDate>
           <comments></comments>
           <description>&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008519151132713.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 508px; HEIGHT: 254px&quot; border=0 hspace=0 alt=&quot;GW13-40.5/72.5/126 series high-voltage isolation switch model description&quot; src=&quot;/uploadfiles/200805/2008519151132713.jpg&quot; width=508 height=254&gt;&lt;/A&gt;&lt;BR&gt;Structure Introduction&lt;BR&gt;The isolation switch consists of a bracket, base, post insulator, contact, terminal block, and other parts. The post insulators and conductive parts are installed on the base, with an intersection angle of 50 &#176; between the two post insulators. The base is fixed on a bracket tilted at 25 degrees. The bracket is equipped with a shaft connected to the operating mechanism. Can be equipped with CS17G manual operating mechanism or CJ6 electric mechanism.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GW13-40.5/72.5/126 series high-voltage isolating switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated short-time&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated peak value&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;pressure resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;DIV align=center&gt;GW13£­40.5£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;40£®5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;8%&quot;&gt;
&lt;DIV&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;13%&quot;&gt;
&lt;DIV&gt;20/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;13%&quot;&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;DIV align=center&gt;GW13£­72.5£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;72£®5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;DIV align=center&gt;GW13£­126£¨W£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200807/200872322427441.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 720px&quot; border=0 hspace=0 alt=&quot;GW13-40.5/72.5/126 series high-voltage isolation switch external dimensions and technical parameters table&quot; src=&quot;/uploadfiles/200807/200872322427441.jpg&quot; width=680 height=720&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200807/20087232251169.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 820px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW13-40.5/72.5/126 series high-voltage isolation switch&quot; src=&quot;/uploadfiles/200807/20087232251169.jpg&quot; width=680 height=820&gt;&lt;/A&gt;&lt;BR&gt;GW13-40.5/72.5/126 series high-voltage isolation switch&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW10 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/3303.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of GW10 outdoor high-voltage isolation switch:&lt;BR&gt;&lt;BR&gt;Rated voltage (kV): 12; fifteen&lt;BR&gt;Rated current (A): 630&lt;BR&gt;Rated short-time withstand current (kA): 20 (4S)&lt;BR&gt;Rated peak withstand current (kA): 42~50&lt;BR&gt;Power frequency withstand voltage (fracture) (kV): 48&lt;BR&gt;Power frequency withstand voltage (relative to ground) (kV): 42&lt;BR&gt;Lightning impulse withstand voltage (fracture) (kV): 85&lt;BR&gt;Lightning impulse withstand voltage (relative to ground) (kV): 75&lt;BR&gt;Mechanical lifespan (times): 2000&lt;/P&gt;
&lt;P align=center&gt;GW10 outdoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]HGW10 Outdoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/3302.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:11</pubDate>
           <comments></comments>
           <description>Technical parameters of HGW10 outdoor AC high voltage isolation switch:&lt;BR&gt;&lt;BR&gt;Rated voltage (kV): 12; fifteen&lt;BR&gt;Rated current (A): 630&lt;BR&gt;Rated short-time withstand current (kA): 20 (4S)&lt;BR&gt;Rated peak withstand current (kA): 42~50&lt;BR&gt;Power frequency withstand voltage (fracture) (kV): 48&lt;BR&gt;Power frequency withstand voltage (relative to ground) (kV): 42&lt;BR&gt;Lightning impulse withstand voltage (fracture) (kV): 85&lt;BR&gt;Lightning impulse withstand voltage (relative to ground) (kV): 75&lt;BR&gt;Mechanical lifespan (times): 2000&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW15-12-40.5-72.5 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/3300.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:21:03</pubDate>
           <comments></comments>
           <description>GW15-12-40.5-72.5 outdoor high-voltage isolation switch is a three-phase AC outdoor high-voltage transmission equipment with a frequency of 50Hz, used to disconnect or connect high-voltage lines under no-load conditions, change the operation mode of distribution equipment and busbars, and achieve safe electrical isolation during maintenance of busbars, circuit breakers and other electrical equipment. This product has a double column horizontal fracture vertical opening structure, and its fracture is clearly visible after opening, which is conducive to inspection. The product has the advantages of small footprint, small inter phase distance, simple structure, easy operation, and simple appearance. The conductive switch adopts a two-step action, that is, after the moving contact comes into contact with the static contact seat, the moving contact flips 40 &#176;, so that the contact pressure between the moving and static contacts is stable and reliable, achieving close contact with the static contact finger. The assembly of the static contact seat adopts an internal hidden external pressure structure, and the contact finger spring will not produce any diversion. The rotating part bearings adopt double sealed and self-lubricating bearings to maintain good lubrication and flexible rotation, and generally require minimal maintenance. This product can be supplied from above ground level. This product complies with GB1985-2004 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot;, and is equivalent to IEC60129 (1984) &quot;AC High Voltage Isolating Switches and Grounding Switches&quot; and GB/T11022-1999 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;. This product is equipped with rod-shaped pillar composite insulators (which can also be equipped with porcelain insulators, classified into three level and four level anti fouling types according to the pollution conditions of use). According to the grounding method, it can be divided into four forms: &quot;ungrounded&quot;, &quot;front grounded (with grounding switch on the auxiliary contact side)&quot;, &quot;rear grounded (with grounding switch on the main contact side)&quot;, and &quot;double grounded&quot;. &lt;BR&gt;&lt;BR&gt;Product classification&lt;BR&gt;1¡¢ GW15£­12¡¢ The 40.5 and 72.5 outdoor isolation switches are composed of three independent single-phase isolation switches, an integral channel steel crossbeam, and two columns. They are the basic unit of the derived grounding switch.&lt;BR&gt;2. Install one grounding switch for each phase of the front grounding switch (with a grounding switch on the side of the auxiliary contact finger seat).&lt;BR&gt;3. Install one grounding switch for each phase of the rear grounding switch (with a grounding switch on the main contact finger seat side).&lt;BR&gt;4. Two grounding switches are installed for each phase of the double grounding switch.&lt;BR&gt;5. The installation method is horizontal installation.&lt;BR&gt;6. According to the operation mode, it can be divided into three pole linkage or single pole operation.&lt;BR&gt;7. According to the type of insulator material used, ceramic insulators and composite insulators are classified.&lt;BR&gt;8. According to the working environment, it is divided into Level III anti fouling and Level IV anti fouling.&lt;BR&gt;9. According to the operating mechanism, the main knife (isolation switch) has two types of operating mechanisms: electric and manual, while the ground knife (grounding switch) only has a manual operating mechanism. When the main knife is manually operated, use the CS17-G hand operated mechanism or the CS9-G hand operated mechanism, and use the CS17-G hand operated mechanism for the ground knife.&lt;BR&gt;&lt;BR&gt;Technical parameters of GW15-12-40.5-72.5 outdoor high-voltage isolation switch&lt;BR&gt;1. The main technical parameters of the isolation switch are shown in Table 1, Table 1. Classification model, rated voltage, kV, rated current, A, isolation switch, grounding switch, grounding type, matching mechanism, rated peak withstand current, kA (peak), rated short-time withstand current, kA/4s (effective value), rated peak withstand current, kA (peak), rated short-time withstand current, kA/4s (effective value), isolation switch, grounding switch, anti fouling type, GW15-12 40.5 72.5 630 50 20 50 20, ungrounded, left single grounding, right single grounding, double grounding, hand-operated or manually operated mechanism, electric mechanism CS17-G ¡¡ 1250 80 31.5 80 31.5 ¡¡ ¡¡ 1600 100 40 100 40 ¡¡ 2000 ¡¡ 2500 ¡¡ Note: The maximum rated current of 12kV is 1250A. When ordering, please specify the product model, rated voltage, rated current, grounding type (front grounding, rear grounding, double grounding, ungrounded), anti fouling level, and special requirements for manual and electric mechanisms&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1-12G(D) series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/3298.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:54</pubDate>
           <comments></comments>
           <description>The GW1-12G (D) series outdoor high-voltage isolation switch is a new type of switch designed according to current national and international standards to address a series of issues with the original GW1 switch. The switch itself has a grounding switch and is equipped with a CS8 manual mechanism to effectively prevent misoperation such as &quot;live grounding wire hanging and grounding wire closing&quot;. Operators do not need to hang another grounding wire. This product has excellent electrical and mechanical performance, meeting the requirements of national standard GB1985 and international electrical standards IEC129 and IEC694. It is an updated product of the current 10kV outdoor switch.&lt;BR&gt;&lt;BR&gt;GW1-12G (D) series outdoor high-voltage isolation switch adaptability range&lt;BR&gt;Switches are used for three-phase AC 50Hz circuits, for use in time division circuits with voltage and no load. The usage conditions are as follows: (1) The altitude should not exceed 3000m, and the ambient temperature should not be lower than -40 ¡æ or higher than+40 ¡æ. (2) The wind speed shall not exceed 35m/s, and the seismic intensity shall not exceed 8 degrees. (3) Suitable for polluted areas such as cities and industrial and mining areas. (4) Not suitable for places with combustion and explosion hazards, severe vibrations and impacts, and chemical substances that severely corrode metals and insulation materials.&lt;BR&gt;&lt;BR&gt;GW1-12G (D) series outdoor high-voltage isolation switch model and specifications&lt;BR&gt;Model, structure, form, current level 630A 1000A 1250A ungrounded GW1-12G/630 GW1-12G/1000 GW1-12G/2.400.630.1000.1250 A moving contact grounding GW1-12G (D1)/630 GW1-12G (D1)/1000 GW1-12G (D1)/1250 static contact grounding GW1-12G (D1)/630 GW1-12G (D2)/1000 GW1-12G (D2)/1250&lt;BR&gt;&lt;BR&gt;3. Main structure (1): The isolation switch is a three-phase electrical appliance composed of three separate single pole isolation switches. There are three structural forms: ungrounded, moving contact grounded, and stationary contact grounded. Each single pole isolation switch has the same components, such as the base pillar and the front and rear static contacts of the operating insulator, the switch blade, and the arc angle. Its appearance and main dimensions are shown in Table 2.&lt;BR&gt;a. Base: The base is made of 4.5mm thick soft steel plate bent, with a shaft with a pull arm crossing the middle. There are holes drilled on the base for fixing the post insulator, installing grounding screws, and fixing each pole during installation. There is a slot on the top for the pull arm;&lt;BR&gt;b. The pillars and operating insulators use ZPA-6 type (for 6 kV) and ZPA-10 type (for 12kV) pin insulators, with a minimum bending failure load of 375 and 500 kilograms. The middle operation insulator is used as a pull rod, with clamps fixed on the upper and lower parts, and the upper end connected to the switch blade. The lower end is connected to the pull arm;&lt;BR&gt;c. Front and rear static contacts: The knife holder and tongue are made of purple copper plate and fixed on the post insulator. Extend the horizontal end for wiring purposes, while the bent upper part forms reliable contact with the switch blade on both sides of the wire;&lt;BR&gt;d. Knife switch: Both 400A and 630A are composed of two rectangular cross-section copper plates, while the 200A is composed of one copper plate and one galvanized soft steel plate. Both ends of the blade are equipped with spiral springs to adjust the contact pressure;&lt;BR&gt;e. Arc angle: It is composed of two 5mm steel needles. The stationary part is mounted on the blade tongue, and the movable part is mounted on the blade. (2) The CS8-5 manual knife operating mechanism is suitable for ungrounded switches and can be equipped with F1-4 auxiliary switches; The CS manual operating mechanism is suitable for grounding form isolation switches. It is a new type of single handle dual action manual operating mechanism, which can achieve the operation program of &quot;main opening ground closing ground opening main closing&quot; with one mechanism and one handle, without any misoperation.&lt;BR&gt;&lt;BR&gt;4. Technical Parameters Project Unit Parameters Remarks Rated Voltage kV 12 Grounding Knife and Main Knife Values Same Rated Current A 200, 400, 630, 1000, 1250 Dynamic Stability Current (Peak) kA 15, 25, 50, 63, 100 Thermal Stability Current (Effective Value) kA 7, 14, 20, 25, 40 Thermal Stability Time s 4&lt;BR&gt;&lt;BR&gt;5. Precautions for use (1) Inspection before operation: The contact parts of the conductor should be in good contact, the connection between the switch and the busbar should be reliable, and all moving parts should be flexible. (2) The switch must be operated only after the line load is cut off during operation. (3) The switch should undergo a comprehensive maintenance once a year, which mainly includes inspecting the conductive contact surface, lubricating the moving parts, replacing damaged components, and surface rust prevention treatment.&lt;BR&gt;6. Outline and installation dimensions: GW1-12G/200400.60A GW1-12/200.400.630 type isolating switch Outline drawing Model: Main outline dimensions (mm) H B B1 B2 B3 GW1-12/200 370 670 620 510 GW1-12/400 370 370 620 510 GW1-12/400 670 370 620 510 GW1-12/630 370 670 370 620 510 2. GW1-12/200.400.600 type isolating switch is operated by a CS8-1 manual operating mechanism, and the outline and main dimensions of the operating mechanism are shown in Figure 2. The F1 type auxiliary switch is fixed on the support plate of the operating mechanism, and its boom is connected to the Xiao Zi on the mechanism handle. When the handle is opened and closed by 120 degrees, the auxiliary switch is also opened and closed by 120 degrees. The auxiliary switch is generally used for signal indication and can also be used for electrical interlocking if necessary. The signal wiring is shown in Figure 3. CS8-1 Hand operated Mechanism Outline Drawing Auxiliary Switch Signal Wiring Diagram&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4B-12(W) outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/2299.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:46</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Features&lt;BR&gt;&lt;BR&gt;The GW4B-12 (W) outdoor high-voltage isolation switch is a new type of outdoor high-voltage isolation switch developed by our company. It is characterized by a novel structure, reliable performance, and meets the updated national standards for high-voltage isolation switches. It has the advantages of strong corrosion resistance and pollution resistance, and is suitable for places with poor working environments. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The GW4B-12 (W) outdoor high-voltage isolation switch breaks the traditional structure of similar products in the design and manufacturing process. Its conductive contacts are made of a new type of special material, and the conductive contacts are self operated. The traditional high-voltage isolation switch's conductive contacts are compressed by a spring, which often reduces the clamping force of the contacts due to the heating of the spring during operation, forming a vicious cycle. The self operated contacts can effectively exhaust this situation and keep the contacts in good working condition. The rotating part of the conductive contact blade adopts a stainless steel shaft and oil-free lubricated bearing structure to ensure lightweight and flexibility, and there will be no jamming phenomenon. All black metal parts are treated with powder infiltration new technology and then coated with protective paint for double protection to ensure that the product is in good working condition for 20 years. Not corroded.&lt;BR&gt;&lt;BR&gt;main purpose&lt;BR&gt;&lt;BR&gt;GW4B-12 (W) type isolating switch is an outdoor high-voltage electrical appliance used for closing and breaking AC power circuits with a rated voltage of 12KV and a rated frequency of 50HZ, with voltage and no load.&lt;BR&gt;&lt;BR&gt;Applicable environmental conditions&lt;/P&gt;
&lt;P align=left&gt;a. Altitude: not exceeding 2000m;&lt;BR&gt;b. Surrounding air temperature: -30 ¡æ to+40 ¡æ;&lt;BR&gt;c. Wind speed not exceeding 35m/s;&lt;BR&gt;d. No obvious pollution sites such as severe dust, pollution, flammable and explosive substances, chemical corrosion, etc;&lt;BR&gt;e. No places with frequent and severe vibrations.&lt;BR&gt;&lt;BR&gt;Main structure of the product&lt;BR&gt;&lt;BR&gt;a. GW4B-12 (W) type isolating switch is a three-phase linkage type, equipped with CS11 type manual operating mechanism. Two post insulators are fixed on the bearing seats at both ends of the base, connected by joints and connecting rods. When rotating horizontally, one post insulator is rotated, while the other post insulator is pulled to rotate in the opposite direction, causing the contact blade to separate or close. The rotation angle of the post insulator is about 90 &#176;. When the three are connected, the poles are linked by connecting rods. The creepage distance of the post insulator used in the isolation switch is ¡Ý 31mm/kv.&lt;BR&gt;b. The operating mechanism consists of an operating handle, a base, an auxiliary switch, a cover, and a positioning locking device. The operating handle rotates 90 degrees. Equipped with F6 auxiliary switch, it is used to transmit the &quot;open&quot; and &quot;close&quot; signals of the main switch and the electrical interlocking information between the isolation switch and the circuit breaker.&lt;BR&gt;c. The black metal components in the isolation switch and manual operating mechanism are both treated with hot-dip galvanizing or vacuum powder galvanizing technology to prevent corrosion.&lt;BR&gt;&lt;BR&gt;Technical data&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200705/200752085154719.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 129px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GW4B-12 (W) Outdoor High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200705/200752085154719.gif&quot; width=553 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GW4B-12 (W) outdoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GWZ-3.6 outdoor DC isolation switch </title>
           <link>http://www.91way.com/info_en/2298.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GWZ-3.6 Outdoor DC Isolation Switch&lt;BR&gt;&lt;BR&gt;a. GWZ-3.6 outdoor DC isolation switch is a new type of isolation switch developed by our company for urban underground railways and urban light rails. It is used for breaking and closing voltage free circuits in subway electric locomotives and urban light rail DC 3600V and below power lines.&lt;BR&gt;b. This type of DC isolation switch has a novel structure and reliable performance.&lt;BR&gt;c. The main electrical part of this type of DC isolation switch adopts a plug-in type with self-cleaning function. The contact fingers of the movable contact parts are made of special materials with high strength, high elasticity, and high conductivity, overcoming the disadvantages of traditional switches that use springs to press the contacts and fingers, which are prone to heat generation and reduce the clamping force of the fingers during operation, ensuring that the fingers always maintain good working condition.&lt;BR&gt;d. The rotating friction part of the transmission part of this type of DC isolation switch adopts oil-free self-lubricating bearings to ensure easy and flexible operation, reduce wear, and extend service life.&lt;BR&gt;e. All black metal parts of this type of DC isolation switch are treated with vacuum powder zinc infiltration technology and then coated with protective paint for dual protection, which has strong anti pollution and anti-corrosion capabilities.&lt;BR&gt;&lt;BR&gt;Main structure of the product&lt;BR&gt;a. The GWZ-3.6 DC isolation switch is a single pole type, consisting of the isolation switch body, CS manual operating mechanism, and accessories.&lt;BR&gt;b. This isolation switch is opened vertically, with a break and a distance to ground of not less than 200mm.&lt;BR&gt;c. This isolation switch consists of a base channel steel, a post insulator, an operating insulator terminal block, a conductive rod, contacts, and contact fingers.&lt;BR&gt;Environmental conditions for use&lt;BR&gt;a. Altitude: not exceeding 2000 meters.&lt;BR&gt;b. Surrounding air temperature: -30 ¡æ+40 ¡æ.&lt;BR&gt;c. The wind speed shall not exceed 35m/s.&lt;BR&gt;d. There are no obvious pollution sites such as severe dust, pollution, explosive and flammable substances, and chemical corrosion.&lt;BR&gt;e. No places with frequent and severe vibrations.&lt;BR&gt;&lt;BR&gt;Technical data&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200705/200752084933591.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 528px; HEIGHT: 132px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GWZ-3.6 Outdoor DC Isolation Switch&quot; src=&quot;/uploadfiles/200705/200752084933591.gif&quot; width=528 height=132&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center ?msotablegrid?=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;&lt;BR&gt;rated voltage&lt;/P&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;&lt;BR&gt;rated current&lt;/P&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;&lt;BR&gt;loop resistance&lt;/P&gt;
&lt;P align=center&gt;¦Ì¦¸&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;&lt;BR&gt;4S short-time withstand current kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;&lt;BR&gt;1-minute withstand voltage&lt;/P&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;BR&gt;Supporting organization&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=54&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;BR&gt;Weight Kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;GWZ-3.6/1250&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=72&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;three point six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=72&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=72&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;CS&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=54&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;GWZ-3.6/2000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=54&gt;
&lt;P align=center&gt;twenty-seven point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;GWZ-3.6/3150&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=54&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5-40.5D(W)/630 Outdoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/1752.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:29</pubDate>
           <comments></comments>
           <description>The GW5 series outdoor AC isolation switch is an outdoor high-voltage electrical equipment with an AC frequency of 52Hz, with rated voltage levels of 40.5kV, 72.5kV, and 126kV. It is used for opening and closing high-voltage lines under no-load conditions, as well as for electrically isolating high-voltage busbars, circuit breakers, and other electrical equipment under maintenance from live high-voltage circuits. It can also be used for opening and closing small capacitor or inductor currents.&lt;BR&gt;&lt;BR&gt;GW5-40.5D (W)/630 outdoor AC high voltage isolation switch meets the relevant provisions of GB1985 &quot;AC High Voltage Isolation Switches and Grounding Switches&quot;, IEC60129 &quot;AC Isolation Switches and Grounding Switches&quot;, and GB/T11022 &quot;Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards&quot;.&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;A href=&quot;/uploadfiles/200701/2007159529771.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 242px&quot; border=0 hspace=0 alt=&quot;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200701/2007159529771.jpg&quot; width=500 height=242&gt;&lt;/A&gt;&lt;BR&gt;Environmental conditions for use:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;+Altitude: not exceeding 3000m;&lt;BR&gt;+Surrounding air temperature: upper limit 40 ¡æ, lower limit -25 ¡æ;&lt;BR&gt;+Wind speed not exceeding 35m/s;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+The pollution level shall not exceed level III;&lt;BR&gt;+The thickness of ice cover shall not exceed 10mm;&lt;BR&gt;+The installation site should be free from flammable, explosive hazards, chemical corrosion, and severe vibrations.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD rowSpan=3 width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;Classification&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;28%&quot;&gt;
&lt;DIV align=center&gt;Model number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;BR&gt;£¨V£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;BR&gt;£¨A£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;disconnecting switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;grounding switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;grounding&lt;BR&gt;kind&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;peak&lt;BR&gt;tolerance&lt;BR&gt;current&lt;BR&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;short-term&lt;BR&gt;tolerance&lt;BR&gt;current&lt;BR&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;peak&lt;BR&gt;tolerance&lt;BR&gt;current&lt;BR&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;short-term&lt;BR&gt;tolerance&lt;BR&gt;current&lt;BR&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Type I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Type I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Type I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Type II&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Type I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Type II&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;General type&lt;BR&gt;(Anti fouling type)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 96%; BORDER-COLLAPSE: collapse&quot; border=0 cellSpacing=1 cellPadding=1 width=&quot;96%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;32%&quot;&gt;
&lt;DIV align=right&gt;GW5&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=right&gt;HGW5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;SPAN&gt;-40.5&lt;/SPAN&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;37%&quot;&gt;
&lt;DIV align=left&gt;(D¡¢DW)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;-72.5¢ò&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;SPAN&gt;-126&lt;/SPAN&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;forty point five&lt;BR&gt;seventy-two point five&lt;BR&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;20 (4s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;twenty&lt;BR&gt;(4s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;BR&gt;(4s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;not grounded&lt;BR&gt;Single grounding&lt;BR&gt;&lt;SPAN style=&quot;FONT-FAMILY: ËÎÌå&quot;&gt;Double grounding&lt;/DIV&gt;&lt;/SPAN&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;31.5 (4s)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;31.5 (4s)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=left&gt;&lt;BR&gt;Structure Introduction:&lt;BR&gt;Each isolation switch consists of two pole insulators, each fixed on a base at an angle of 50 &#176;&lt;SPAN class=style1&gt;The V-shaped structure mainly consists of the following parts: base part, post insulator, terminal block part, contact part, grounding knife, grounding static contact, terminal block, etc.&lt;BR&gt;This isolation switch is divided into three types: ungrounded, single grounded, and double grounded. There is a mechanical interlock between the spindle and the grounding knife, and it is equipped with an auxiliary switch. There are two operation modes for the switch: manual and electric.&lt;BR&gt;&lt;BR&gt;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch Appearance and Installation Dimensions:&lt;/P&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200701/2007159301258.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 526px; HEIGHT: 808px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW5-40.5D (W)/630 outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200701/2007159301258.jpg&quot; width=526 height=808&gt;&lt;/A&gt;&lt;BR&gt;&lt;SPAN&gt;Figure 1 GW5-40.5 (126) D/630 Single pole Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200701/20071593256816.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 210px&quot; border=0 hspace=0 alt=&quot;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch Structure Diagram&quot; src=&quot;/uploadfiles/200701/20071593256816.jpg&quot; width=650 height=210&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200701/20071593317142.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 350px&quot; border=0 hspace=0 alt=&quot;Installation Diagram of GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200701/20071593317142.jpg&quot; width=650 height=350&gt;&lt;/A&gt;&lt;BR&gt;&lt;SPAN&gt;&lt;BR&gt;Figure 2 Installation diagram of switch three pole linkage&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;Model number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;Rated voltage (kV)&lt;SPAN style=&quot;FONT-FAMILY: ËÎÌå&quot;&gt;£©&lt;/DIV&gt;&lt;/SPAN&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L1 (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L2 (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L3 (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L4 (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L5 (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;L1 (mm)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW5-110&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«2800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1473&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1569&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1533&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1362&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW5-35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«830&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«1000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«845&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«700&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200701/20071593547208.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 520px; HEIGHT: 388px&quot; border=0 hspace=0 alt=&quot;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch Mechanism Diagram&quot; src=&quot;/uploadfiles/200701/20071593547208.jpg&quot; width=520 height=388&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200701/20071593555233.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 494px; HEIGHT: 292px&quot; border=0 hspace=0 alt=&quot;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch Distribution Diagram&quot; src=&quot;/uploadfiles/200701/20071593555233.jpg&quot; width=494 height=292&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200701/2007159363787.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 211px; HEIGHT: 137px&quot; border=0 hspace=0 alt=&quot;GW5-40.5D (W)/630 outdoor AC high voltage isolation switch phase to phase distance&quot; src=&quot;/uploadfiles/200701/2007159363787.jpg&quot; width=211 height=137&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GW5-40.5D (W)/630 Outdoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;&lt;/SPAN&gt;&lt;/SPAN&gt;&lt;/SPAN&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-126D(W) Outdoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/1662.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:20</pubDate>
           <comments></comments>
           <description>GW4-126 outdoor AC high voltage isolation switch (hereinafter referred to as isolation switch). Suitable for power systems with a frequency of 50Hz and a rated voltage of 126kV, used as a switching circuit when there is voltage and no load. The anti fouling isolation switch can meet the requirements of users in heavily polluted areas and effectively solve the problem of pollution flashover during the operation of the isolation switch. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Model and its meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/20061212164236132.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 240px&quot; border=0 hspace=0 alt=&quot;GW4-126D (W) Outdoor AC High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200612/20061212164236132.jpg&quot; width=500 height=240&gt;&lt;/A&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude: below 3000m;&lt;BR&gt;+Environmental temperature: upper limit of 40 ¡æ, decrease by -25 ¡æ;&lt;BR&gt;+Wind speed not exceeding 35m/s;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+The thickness of ice cover shall not exceed 10mm;&lt;BR&gt;+Pollution resistant products are suitable for heavily polluted areas;&lt;BR&gt;+The installation site should be free from flammable, explosive hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;&lt;BR&gt;GW4-126D (W) Outdoor AC High Voltage Isolation Switch Main Technical Parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;serial number&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Project&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;unit&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Technical specifications&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Remarks&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;one&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;rated voltage&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kV&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;one hundred and twenty-six&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;two&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;rated current&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;A&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;six hundred and thirty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;one thousand two hundred and fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;three&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Rated peak withstand current&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kA&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;eighty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;four&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN lang=EN-US&gt;4s&lt;/SPAN&gt;&lt;SPAN&gt;Short time withstand current&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kA&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;twenty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;thirty-one point five&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;five&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Rated static tension of the terminal&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;N&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;seven hundred and thirty-five&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;six&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;rated frequency&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;Hz&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;seven&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN lang=EN-US&gt;1min&lt;/SPAN&gt;&lt;SPAN&gt;Power frequency withstand voltage (effective value)&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kV&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Jijian&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;*&lt;/SPAN&gt;&lt;SPAN&gt;Extremely to the ground&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;eight hundred and fifteen&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;*&lt;/SPAN&gt;&lt;SPAN&gt;Suitable for three pole linkage&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;fracture&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;two hundred and ten&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;eight&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Lightning impulse withstand voltage (effective value)&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kV&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Jijian&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;*&lt;/SPAN&gt;&lt;SPAN&gt;Extremely to the ground&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;four hundred and fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;*&lt;/SPAN&gt;&lt;SPAN&gt;Suitable for three pole linkage&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;fracture&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;five hundred and twenty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;nine&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Product single pole weight (body)&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kg&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;¡Ö&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;two hundred and forty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;ten&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Supporting organization&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Isolating switch:&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;CS14&lt;/SPAN&gt;&lt;SPAN&gt;Manual mechanism&lt;BR&gt;Grounding switch:&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;CS14&lt;/SPAN&gt;&lt;SPAN&gt;Manual mechanism&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Selected by the user&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;eleven&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Grounding form&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Ungrounded, single grounded, or double grounded&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;twelve&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Crawling distance of pillar insulators&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;mm&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Normal type&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;one thousand eight hundred and seventy&lt;/SPAN&gt;&lt;SPAN&gt;Pollution resistant type&lt;/SPAN&gt;&lt;SPAN lang=EN-US&gt;three thousand and fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Special orders can also be accepted&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;thirteen&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=left&gt;&lt;SPAN&gt;Assemble grounding switch&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Short time withstand current&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kA&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;12.5(2s)&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;20(2s)&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN&gt;Peak withstand current&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;kA&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;thirty-one point five&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;SPAN lang=EN-US&gt;fifty&lt;/SPAN&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Main structural description&lt;BR&gt;The isolation switch is a double column horizontal rotating type, consisting of a chassis, post insulators, conductive system, grounding switch (excluding ungrounded), and transmission system. The products are divided into two types: ordinary type and stain resistant type. The pollution resistant type can be used in Class III polluted areas.&lt;BR&gt;According to user needs, the grounding knife equipped with the product is assembled on the rotating shaft of the base. The static contact is installed on the main electrical system pole, and there is a mechanical interlock between the grounding switch and the isolation switch, which can ensure the sequential action of the main switch and the ground switch and the main switch (the power distribution mechanism can be used as needed).&lt;BR&gt;The isolation switch is made in a single pole form and can form a three pole linkage through inter pole connections. This switch can also be used single pole as needed.&lt;BR&gt;When the isolating switch is equipped with CS14 manual support mechanism, one non grounded mechanism is equipped, two single grounded mechanisms are equipped, and three double grounded mechanisms are equipped.&lt;BR&gt;&lt;BR&gt;GW4-126D (W) Outdoor AC High Voltage Isolation Switch Appearance and Installation Dimensions (The following image can be clicked to enlarge)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/20061212164725223.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 796px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GW4-126D (W) outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200612/20061212164725223.jpg&quot; width=600 height=796&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/2006121216481380.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 795px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GW4-126D (W) outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200612/2006121216481380.jpg&quot; width=600 height=795&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;DIV align=center&gt;Figure 1 GW4-126D ¢ò W (Double Grounding) Outdoor AC High Voltage Isolation Switch (with CS14 Mechanism)&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/20061212164832149.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 210px&quot; border=0 hspace=0 alt=&quot;Installation diagram of GW4-126D (W) outdoor AC high voltage isolation switch base&quot; src=&quot;/uploadfiles/200612/20061212164832149.jpg&quot; width=650 height=210&gt;&lt;/A&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;48%&quot;&gt;Figure 2: Dimensions of the wiring board&lt;/TD&gt;
&lt;TD width=&quot;52%&quot;&gt;
&lt;DIV align=center&gt;Figure 3 Installation dimensions of the base&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-17.5(40.5) Outdoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/1661.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:12</pubDate>
           <comments></comments>
           <description>GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch Model and Its Meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163142627.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 226px&quot; border=0 hspace=0 alt=&quot;GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200612/20061212163142627.jpg&quot; width=500 height=226&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude not exceeding 3000m;&lt;BR&gt;+The upper limit of ambient temperature is+40 ¡æ, and the lower limit is -25 ¡æ;&lt;BR&gt;+Wind speed not exceeding 35m/s;&lt;BR&gt;+Places without conductive or chemically reactive gases and vapors;&lt;BR&gt;+Places without fire or explosion hazards (with pollution levels not exceeding Level III);&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch Main Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Peak withstand current (kA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4-second short-time withstand current (kA)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=1 width=&quot;96%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;GW4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;-17.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;HGW4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;seventeen point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;
&lt;TABLE border=0 cellSpacing=1 cellPadding=1 width=&quot;96%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;GW4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;40.5(D)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;HGW4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Main structural description:&lt;BR&gt;&lt;BR&gt;The isolation switch consists of a base, insulating support, conductive parts, and operating mechanism. Each pole has two pillars, and each pillar is equipped with a conductive blade at the upper end. The contact points of the two blade contacts are located in the middle of the two pillars. The lower ends of the pillars are equipped with bearing sleeves, which, under the drive of the operating mechanism, can rotate the blade horizontally by 90 degrees to achieve the requirements of opening and closing the switch. The isolation switch is a single pole type, and it can also be connected by a connecting rod to form a linkage pole type. Equipped with CS11 (ungrounded), CS8-6D (single grounded), CS17 (double grounded) manual mechanisms for operation. It is not difficult to see from the above structural introduction that the structure of this isolation switch is reasonable and the operation is flexible and easy; Can be used as a single pole or three pole, easy to install; The contact blade has a large opening distance, ensuring safe and reliable insulation. According to user needs, it can be ungrounded or equipped with single-sided grounding or double grounding.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163526584.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW4-17.5 (40.5) outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200612/20061212163526584.jpg&quot; width=650 height=330&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;DIV align=center&gt;Figure 1 GW4-17.5D/630 Three pole Linkage Assembly Diagram&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163616388.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 628px&quot; border=0 hspace=0 alt=&quot;GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200612/20061212163616388.jpg&quot; width=600 height=628&gt;&lt;/A&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163629407.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 583px; HEIGHT: 621px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW4-17.5 (40.5) outdoor AC high-voltage isolation switch mechanism&quot; src=&quot;/uploadfiles/200612/20061212163629407.jpg&quot; width=583 height=621&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Figure 2 GW4-17.5D/630 Single pole Isolation Switch&lt;/DIV&gt;
&lt;DIV align=left&gt;&lt;BR&gt;Assembly form: Single pole assembly or three pole linkage assembly (the following image can be clicked to enlarge)&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163747780.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 390px&quot; border=0 hspace=0 alt=&quot;GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch Assembly Drawing&quot; src=&quot;/uploadfiles/200612/20061212163747780.jpg&quot; width=650 height=390&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Figure 3 Assembly diagram of GW4-40.5D/630 three pole linkage&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163813324.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 592px&quot; border=0 hspace=0 alt=&quot;GW4-17.5 (40.5) Outdoor AC high voltage isolation switch single pole&quot; src=&quot;/uploadfiles/200612/20061212163813324.jpg&quot; width=500 height=592&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Figure 4 GW4-40.5D/630 Single pole Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200612/20061212163851228.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 216px&quot; border=0 hspace=0 alt=&quot;GW4-17.5 (40.5) Outdoor AC High Voltage Isolation Switch Base Diagram&quot; src=&quot;/uploadfiles/200612/20061212163851228.jpg&quot; width=500 height=216&gt;&lt;/A&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;&lt;BR&gt;Please indicate when placing an order:&lt;BR&gt;Product name, model, and main technical data; Environmental conditions for use; Installation method and requirements for grounding devices; Model of operating mechanism; If there are other special requirements, they can be resolved through negotiation&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW9-15kV Outdoor isolation switch </title>
           <link>http://www.91way.com/info_en/1361.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:20:04</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/2006111194122224.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 357px; HEIGHT: 246px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW9-15kV outdoor isolation switch&quot; src=&quot;/uploadfiles/200611/2006111194122224.gif&quot; width=357 height=246&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2&gt;Model Type&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Rated Voltage kV&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2&gt;4S heat steady current (A)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Shock current A to stabilize customer current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Impulse withstand voltage (kV)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Power frequency withstand voltage (kV)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD align=middle&gt;Relatively Earth&lt;/TD&gt;
&lt;TD align=middle&gt;Between fractures&lt;/TD&gt;
&lt;TD align=middle&gt;Relatively Earth&lt;/TD&gt;
&lt;TD align=middle&gt;Between fractures&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=33&gt;GW9-15G/400&lt;/TD&gt;
&lt;TD height=33&gt;fifteen&lt;/TD&gt;
&lt;TD height=33&gt;four hundred&lt;/TD&gt;
&lt;TD height=33&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD height=33&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD height=33&gt;seventy-five&lt;/TD&gt;
&lt;TD height=33&gt;eighty-five&lt;/TD&gt;
&lt;TD height=33&gt;thirty-eight&lt;/TD&gt;
&lt;TD height=33&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GW9-15G/630&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;eighty-five&lt;/TD&gt;
&lt;TD&gt;thirty-eight&lt;/TD&gt;
&lt;TD&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GW9-15kV outdoor isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW8,GW13 series neutral point isolation switch </title>
           <link>http://www.91way.com/info_en/868.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:55</pubDate>
           <comments></comments>
           <description>The GW8 and GW13 series neutral point isolation switches are AC 50HZ outdoor devices used for connecting the neutral points of transformers when there is no load. GW8-35, 60110G/400G models are operated by CS8-1 manual operating mechanism; GW13-35£¬ 63110/630 type is operated by an electric motor operating mechanism or CS17-G type manual operating mechanism.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;rated voltage&lt;BR&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;maximum voltage&lt;BR&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;(Peak) KA&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Thermal stability current&lt;BR&gt;KA-S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;creepage distance&lt;BR&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Rated static tension of terminal N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;weight&lt;BR&gt;KG&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW8-35G(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;8-4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Regular 625&lt;BR&gt;Anti pollution 875&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW8-60G(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Ordinary 1100&lt;BR&gt;Anti pollution 1600&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW8-110G(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Ordinary 1870&lt;BR&gt;Anti pollution 2750&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~120&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW13-35(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;16-4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Regular 625&lt;BR&gt;Anti pollution 875&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW13-63(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Ordinary 1100&lt;BR&gt;Anti pollution 1600&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~233&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW13-110(W)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Ordinary 1870&lt;BR&gt;Anti pollution 2750&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;~244&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5 series outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/867.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:47</pubDate>
           <comments></comments>
           <description>The GW5 series outdoor high voltage isolation switch is a three-phase AC 50HZ outdoor high voltage electrical device used for voltage and no-load division circuits. &amp;nbsp;&lt;BR&gt;The GW5 series outdoor high-voltage isolation switches are divided into two types based on their external insulation capacity: ordinary type and pollution resistant type. Both types can be equipped with grounding switches, which can be single grounded or double grounded. Grounding switches are further divided into Type I and Type II based on their ability to withstand the thermal effects of short-circuit currents.&lt;BR&gt;&lt;BR&gt;Structure:&lt;BR&gt;The GW5 series outdoor high-voltage isolation switch is equipped with a CS17 manual operating mechanism, which is equipped with an electromagnetic lock and an interlocking board to achieve interlocking between the main switch blade of the isolation switch and the grounding switch.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Product Model Type&lt;BR&gt;Parameter Data&lt;BR&gt;Project Name: Item&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;GW5-40.5D&lt;BR&gt;D(W)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;GW5-72.5D&lt;BR&gt;D(W)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;GW5-126D&lt;BR&gt;D(W)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated Voltage KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=left&gt;Rated current A&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;630 1250 1600&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short time withstand current (RMS) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;20 31.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short circuit suspected time S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated peak withstand current (peak) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;50 80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated mechanical load of terminal (axial)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;33%&quot;&gt;
&lt;P align=left&gt;Rated short-time power frequency withstand voltage (effective value)&lt;BR&gt;Rated short-time power frequence ¡¡¡¡&lt;BR&gt;withstand voltage(rms) kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;to the ground&lt;BR&gt;to each&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;fracture&lt;BR&gt;between breaks&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=left&gt;Rated lightning impulse withstand voltage (peak)&lt;BR&gt;Lightning impulse withstand&lt;BR&gt;voltage(peak) KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;to the ground&lt;BR&gt;to each&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;fracture&lt;BR&gt;between breaks&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=left&gt;Rated parameters of grounding switch assembled with isolation switch&lt;BR&gt;Technical data of earthing switch is connected with disconnector&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;Type I&lt;BR&gt;Type&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;4s rated short-time withstand current (effective value)&lt;BR&gt;4s short time withstand current(rms) kA&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Rated peak withstand current (peak)&lt;BR&gt;Peak withstand current(peak) kA&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=left&gt;Type II&lt;BR&gt;Type¢ò&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;1-second rated short-time withstand current (effective value)&lt;BR&gt;1s short time withstand current(rms) kA&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;20 31.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current (peak)&lt;BR&gt;Peak withst and current(peak) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;50 80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1 series outdoor single-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/866.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:38</pubDate>
           <comments></comments>
           <description>The GW1 outdoor single-phase four phase high voltage isolation switch consists of a base, pillar porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=40 width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum working electricity&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KV (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;10s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;weight&lt;BR&gt;kg&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-6/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-6/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23&gt;
&lt;DIV align=center&gt;GW1-10/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-10/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-10/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-10W/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-10W/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GW1-10W/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GW1 series outdoor single-phase high voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW9-12(W) series outdoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/834.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:29</pubDate>
           <comments></comments>
           <description>GW9-12 (W) series outdoor high-voltage isolation switch is a single pole structure high-voltage switchgear used for opening and closing circuits in outdoor 12 kV line networks with voltage and no load. Equipped with fixed hooks and self-locking devices, flexible and reliable, using insulated hook rods for operation. The anti pollution outdoor high-voltage isolation switch can meet the requirements of users in severely polluted areas and effectively solve the problem of pollution flashover during the operation of the isolation switch&lt;BR&gt;&lt;BR&gt;GW9-12 (W) series outdoor AC high voltage isolation switch operating environmental conditions&lt;BR&gt;1. Altitude not exceeding 1000m;&lt;BR&gt;2. Surrounding air temperature: upper limit+40 ¡æ, lower limit -30 ¡æ in general areas, -40 ¡æ in high-altitude areas;&lt;BR&gt;3. The wind pressure shall not exceed 700Pa (equivalent to a wind speed of 34m/s);&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. Places without frequent and severe vibrations;&lt;BR&gt;6. Ordinary installation sites should be free of gases, vapors, chemical deposits, salt spray, dust, and other explosive and corrosive substances that seriously affect the insulation and conductivity of isolation switches;&lt;BR&gt;7. Anti pollution type is suitable for heavily polluted areas, but should not contain substances that can cause fires or explosions.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=122&gt;
&lt;P align=center&gt;model&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=65&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=111&gt;
&lt;P align=center&gt;4S thermal stability current (effective value) 4S&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=140&gt;
&lt;P align=center&gt;Dynamic stability current (peak value)&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=18 colSpan=3&gt;
&lt;P align=center&gt;Full wave impulse withstand voltage&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;power frequency withstand voltage&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Relative to ground (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;P align=center&gt;Between segments&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;Relative to ground (KV)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;P align=center&gt;Between segments&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=122&gt;
&lt;P align=center&gt;GW-12/400-12.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=111&gt;
&lt;P align=center&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=140&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=91&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=160&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=122&gt;
&lt;P align=center&gt;GW-12W/400-12.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=122&gt;
&lt;P align=center&gt;GW9-12/630-20&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=111&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=140&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=91&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=160&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030211134806.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 322px; HEIGHT: 219px&quot; border=0 hspace=0 alt=&quot;Outline Dimensional Drawing of GW9-12 (W) Series Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/20061030211134806.jpg&quot; width=322 height=219&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030211150922.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 460px; HEIGHT: 373px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW9-12 (W) series outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061030211150922.jpg&quot; width=460 height=373&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GW9-12 (W) series outdoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-15 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/787.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:20</pubDate>
           <comments></comments>
           <description>GW4-15 series outdoor AC high voltage isolation switch. Rated current: 200, 400, 630A. Suitable for use in power systems with a frequency of 50Hz and a rated voltage of 15KV, as a time division circuit with voltage and no load, and also for use in railway automatic block signaling devices. And it can be used at a single level. The anti fouling isolation switch can meet the requirements of users in heavily polluted areas and effectively solve the problem of pollution flashover that occurs during the operation of the isolation switch.&lt;BR&gt;&lt;BR&gt;GW4-15 outdoor high-voltage isolation switch operating environment:&lt;BR&gt;Altitude: 1000-3000m area.&lt;BR&gt;Environmental temperature: upper limit+40 ¡æ, lower limit -35 ¡æ (not lower than -40 ¡æ in high-altitude areas).&lt;BR&gt;The wind speed does not exceed 34m/s&lt;BR&gt;Earthquakes should not exceed 8 degrees Celsius.&lt;BR&gt;The thickness of ice cover shall not exceed 10mm.&lt;BR&gt;Pollution resistant products are suitable for heavily polluted areas.&lt;BR&gt;Not suitable for places with flammable substances, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;&lt;BR&gt;Isolation switches are not suitable for:&lt;BR&gt;1. Places where conductive or chemically reactive gases or vapors act;&lt;BR&gt;2. Places where a large amount of dust accumulates;&lt;BR&gt;3. Places with fire and explosion hazards;&lt;BR&gt;4. Places with severe vibrations or impacts.&lt;BR&gt;&lt;BR&gt;Technical parameters of GW4-15 outdoor high-voltage isolation switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=82&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;The highest job&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Extreme Pass&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;4-second thermal stability current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Ice breaking thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Bus Maximum &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Matching operation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Voltage kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Current (peak value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;(Effective value) kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Horizontal tensile force kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Institution model&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;GW4-15/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;seventeen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;CS11-1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;GW4-15/400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;seventeen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;CS11-1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;GW4-15/600&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;seventeen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;thirty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;CS11-1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5¡¢ Ordering Notice:&lt;BR&gt;Clearly state the model and name, rated voltage, and rated current;&lt;BR&gt;Indicate grounding form: ungrounded, single grounded, double grounded;&lt;BR&gt;Installation method; Model and quantity of operating mechanism, whether it is single pole operation or triple pole linkage;&lt;BR&gt;Spare parts and components&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GW4-15 outdoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061029173346559.jpg&quot; width=580 height=260&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4-40.5 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/755.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:11</pubDate>
           <comments></comments>
           <description>GW4-40.5 outdoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]HGW9-10kV series isolating switch </title>
           <link>http://www.91way.com/info_en/409.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:19:02</pubDate>
           <comments></comments>
           <description>HGW9-10kV series isolating switch&lt;BR&gt;&lt;BR&gt;HGW9-10kV&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;Model Type&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;Rated voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot;&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;4S heat stable current (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;10%&quot;&gt;Dynamic stability current Shock current A&lt;/TD&gt;
&lt;TD colSpan=2&gt;Impulse withstand voltage (KV)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Power frequency withstand voltage (KV)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;14%&quot;&gt;Relatively Earth&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;Between fractures&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;Relatively Earth&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;Between fractures&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;10%&quot;&gt;HGW9-10W/200&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;two hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;seventy-five&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;eighty-five&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;thirty-eight&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;10%&quot;&gt;HGW9-10W/400&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;four hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;seventy-five&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;eighty-five&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;thirty-eight&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;10%&quot;&gt;HGW9-10W/630&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;seventy-five&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;eighty-five&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;thirty-eight&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD width=&quot;10%&quot;&gt;HGW9-10W/1000&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;one thousand&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;seventy-five&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;eighty-five&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;thirty-eight&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 376px; HEIGHT: 231px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of HGW9-10kV series isolating switch&quot; src=&quot;/uploadfiles/200610/20061025162819721.gif&quot; width=376 height=231&gt;&lt;BR&gt;&lt;BR&gt;HGW9-10kV series isolating switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW1-12 series outdoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/350.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:18:54</pubDate>
           <comments></comments>
           <description>The GW1 outdoor high-voltage isolation switch (hereinafter referred to as the isolation switch) is suitable for installation on outdoor 12kV lines, for use in the circuit when there is voltage and no load. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The GW1-12 series outdoor AC high voltage isolation switch fully considers the different needs of users and comes in two forms: with grounding knife and without grounding knife. A switch with a grounding knife, equipped with a CS ¡õ type manual mechanism, can prevent misoperation such as hanging a grounding wire when live and closing an isolation switch with a grounding wire. The operator also does not need to hang another grounding wire. This isolation switch has two types: ordinary type and anti fouling type. The anti fouling isolation switch can meet the requirements of severely polluted areas and effectively solve the problem of pollution flashover that occurs during the operation of the isolation switch. The product meets the requirements of standards such as GB1985 and GB/T11022. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;The isolation switch consists of three single pole switches. Each single pole isolation switch has the same components, including a base pillar and an operating insulator&lt;BR&gt;Edge, front and rear static contacts, switch blades, etc. According to user needs, those with grounding knives are equipped with CS ¡õ operating mechanisms, while those without grounding knives are equipped with CS8-&lt;BR&gt;Type 5 operating mechanism. The product has a large opening distance and is easy to operate and reliable. &amp;nbsp;&lt;BR&gt;When there is no circuit breaker on the line or the circuit breaker fails, the isolating switch is allowed to be opened and closed in the following situations:; &amp;nbsp;&lt;BR&gt;Separate and combine the voltage transformers used for measurement; &amp;nbsp;&lt;BR&gt;Separate and combine the charging current on the busbar equipment; &amp;nbsp;&lt;BR&gt;Separate and combine the no-load current of the power transformer (at this time, the capacity of the transformer shall not exceed 750kVA).&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/2006103021114156.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 213px&quot; border=0 hspace=0 alt=&quot;Model Description of GW1-12 Series Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/2006103021114156.jpg&quot; width=500 height=213&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;Rated voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;Maximum working voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;Dynamic stability current kA (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;10S thermal stability current kA (effective value)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-6/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;seven point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-6/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;seven point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10/600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10W/200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10W/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;GW1-10W/600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=59&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=52&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=139&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=218&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;Main dimensions mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;L1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;L&lt;FONT size=1&gt;two&lt;/FONT&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;DIV align=center&gt;A1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=218&gt;
&lt;DIV align=center&gt;GW1-6/200¡¢400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;DIV align=center&gt;two hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=218&gt;
&lt;DIV align=center&gt;GW1-10/200¡¢400¡¢600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three hundred and sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;DIV align=center&gt;three hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW5-40.5 outdoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/347.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:18:45</pubDate>
           <comments></comments>
           <description>The GW5-40.5 outdoor high-voltage isolation switch consists of the GW5-40.5, 126 (D) (W) type isolation switch body, CS17G or CS17G type manually operated mechanism, transmission accessories, etc. It can also be equipped with CJ6 type and other electric mechanisms.&lt;BR&gt;The isolation switch belongs to the double column V-shaped horizontal opening type, and each single stage is composed of a base, a post insulator, an outlet socket, and contacts. It consists of two supports at a 50 &#176; angle, and the two post insulators are installed on the bearings at both ends of the base at an angle to each other, and are perpendicular to the base. The main electrical components are installed above the two pillar insulation porcelain bottles and rotate approximately 90 degrees with the pillar insulation porcelain bottles.&lt;BR&gt;&lt;BR&gt;The copper braided strip soft connections in the GW5-40.5 outdoor high-voltage isolation switch outlet socket are respectively fastened to the conductive rod and the terminal block, which is used by users to connect the circuit.&lt;BR&gt;The contact fingers of the middle contact part are assembled in pairs, using self operated contact fingers in the form of a rotating type to reduce wear between the contacts and fingers during opening and closing, and improve service life.&lt;BR&gt;When the isolation switch is equipped with a grounding switch, the interlocking between the main electrical circuit and the grounding switch is ensured by the fan-shaped plate and arc-shaped plate on the base. When the main electrical circuit is closed, the grounding switch cannot be closed, and when the grounding switch is closed, the main electrical circuit cannot be closed.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Outdoor isolation switch]GW4 series outdoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/192.html</link>
           <author></author>
           <guid></guid>
           <category>Outdoor isolation switch</category>
           <pubDate>2026-6-19 14:18:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GW4 series outdoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;1. Altitude less than 2000m;&lt;BR&gt;2. The maximum ambient temperature shall not exceed+40 ¡æ, the minimum ambient temperature shall not be lower than -30 ¡æ, and the coldest area shall not be lower than -40 ¡æ;&lt;BR&gt;3. The wind speed does not exceed 35m/s;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. The thickness of ice cover shall not exceed 10mm;&lt;BR&gt;6. The installation site should be free of flammable and explosive dangerous goods, chemical corrosion, and severe vibration;&lt;BR&gt;7. Pollution level of post insulators: ordinary type is level 0, and anti fouling type is level II.&lt;BR&gt;&lt;BR&gt;The GW4 series outdoor AC high voltage isolation switch meets the requirements specified in GB1985-89 &quot;AC High Voltage Isolation Switches&quot;, IEC129 (1984) &quot;AC Isolation Switches and Grounding Switches&quot;, and IEC694 (1980) &quot;Common Provisions for High Voltage Switchgear and Control Equipment&quot;.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061020161451600.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 235px&quot; border=0 hspace=0 alt=&quot;Outline Dimensional Drawing of GW4 Series Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/20061020161451600.jpg&quot; width=650 height=235&gt;&lt;/A&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102016153391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 354px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of GW4 Series Outdoor AC High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/2006102016153391.jpg&quot; width=650 height=354&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Note: The values in parentheses in the table are actual experimental values&lt;BR&gt;The bearing seat should rotate flexibly; The wiring socket should rotate flexibly, with a turning angle of not less than 90 degrees; Fasteners should be firm and not loose;&lt;BR&gt;Measure the resistance data of the main circuit&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061020161516469.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 136px&quot; border=0 hspace=0 alt=&quot;GW4 series outdoor AC high-voltage isolation switch circuit resistance&quot; src=&quot;/uploadfiles/200610/20061020161516469.jpg&quot; width=650 height=136&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061020161529154.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 825px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GW4 series outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061020161529154.jpg&quot; width=650 height=825&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061020161541226.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 847px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GW4 series outdoor AC high voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061020161541226.jpg&quot; width=650 height=847&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GW4 series outdoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>