<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - ammeter</title>
       <link>http://www.91way.com</link>
       <description>ammeter</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:14:22</pubDate>
       <item>
           <title>[ammeter]DP3-DA series DC digital ammeter </title>
           <link>http://www.91way.com/info_en/25973.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:52:31</pubDate>
           <comments></comments>
           <description>DP3-DA series DC digital ammeter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Model&lt;/TD&gt;
&lt;TD&gt;range&lt;/TD&gt;
&lt;TD&gt;basic error&lt;/TD&gt;
&lt;TD&gt;resolution&lt;/TD&gt;
&lt;TD&gt;Transformer variation&lt;/TD&gt;
&lt;TD&gt;Maximum allowable input&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA0.2&lt;/TD&gt;
&lt;TD&gt;0.2A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;0.1mA&lt;/TD&gt;
&lt;TD&gt;Direct input&lt;/TD&gt;
&lt;TD&gt;1A (peak value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA2&lt;/TD&gt;
&lt;TD&gt;2A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1mA&lt;/TD&gt;
&lt;TD&gt;Direct input&lt;/TD&gt;
&lt;TD&gt;5A (peak value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA5&lt;/TD&gt;
&lt;TD&gt;5A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;10mA&lt;/TD&gt;
&lt;TD&gt;Direct input&lt;/TD&gt;
&lt;TD&gt;5A (peak value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA20&lt;/TD&gt;
&lt;TD&gt;20A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;10mA&lt;/TD&gt;
&lt;TD&gt;20Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA50&lt;/TD&gt;
&lt;TD&gt;50A&lt;/TD&gt;
&lt;TD&gt;&#177;1%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;50Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA100&lt;/TD&gt;
&lt;TD&gt;100A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;100Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA150&lt;/TD&gt;
&lt;TD&gt;150A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;150Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA200&lt;/TD&gt;
&lt;TD&gt;200A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;200Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA500&lt;/TD&gt;
&lt;TD&gt;500A&lt;/TD&gt;
&lt;TD&gt;&#177;1%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;500Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA1000&lt;/TD&gt;
&lt;TD&gt;1000A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;1000Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA1500&lt;/TD&gt;
&lt;TD&gt;1500A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;1500Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-DA2000&lt;/TD&gt;
&lt;TD&gt;2000A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;2000Aㄩ75mV&lt;/TD&gt;
&lt;TD&gt;1.5F.S&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[ammeter]DP3-AA series AC digital ammeter </title>
           <link>http://www.91way.com/info_en/25971.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:52:22</pubDate>
           <comments></comments>
           <description>DP3-AA series AC digital ammeter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Model&lt;/TD&gt;
&lt;TD&gt;range&lt;/TD&gt;
&lt;TD&gt;basic error&lt;/TD&gt;
&lt;TD&gt;resolution&lt;/TD&gt;
&lt;TD&gt;Transformer variation&lt;/TD&gt;
&lt;TD&gt;Maximum allowable input&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA0.2&lt;/TD&gt;
&lt;TD&gt;0.2A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;0.1mA&lt;/TD&gt;
&lt;TD&gt;Direct input&lt;/TD&gt;
&lt;TD&gt;0.5A (peak value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA2&lt;/TD&gt;
&lt;TD&gt;2A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1mA&lt;/TD&gt;
&lt;TD&gt;Direct input&lt;/TD&gt;
&lt;TD&gt;5A (peak value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA20&lt;/TD&gt;
&lt;TD&gt;20A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;10mA&lt;/TD&gt;
&lt;TD&gt;20Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA50&lt;/TD&gt;
&lt;TD&gt;50A&lt;/TD&gt;
&lt;TD&gt;&#177;1%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;50Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA100&lt;/TD&gt;
&lt;TD&gt;100A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;100Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA150&lt;/TD&gt;
&lt;TD&gt;150A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;150Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA200&lt;/TD&gt;
&lt;TD&gt;200A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;100mA&lt;/TD&gt;
&lt;TD&gt;200Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA500&lt;/TD&gt;
&lt;TD&gt;500A&lt;/TD&gt;
&lt;TD&gt;&#177;1%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;500Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA1000&lt;/TD&gt;
&lt;TD&gt;1000A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;1000Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA1500&lt;/TD&gt;
&lt;TD&gt;1500A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;1500Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DP3-AA2000&lt;/TD&gt;
&lt;TD&gt;2000A&lt;/TD&gt;
&lt;TD&gt;&#177;0.5%F.S&#177;2Digit&lt;/TD&gt;
&lt;TD&gt;1000mA&lt;/TD&gt;
&lt;TD&gt;2000Aㄩ5A&lt;/TD&gt;
&lt;TD&gt;1.2F.S&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[ammeter]PK-I series programmable ammeter </title>
           <link>http://www.91way.com/info_en/25967.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:52:14</pubDate>
           <comments></comments>
           <description>The PK-I series programmable ammeter is an updated product of traditional digital display instruments. In addition to the display function of traditional products, this product also has programmable function, DC4-20mA analog transmission output, RS485 communication interface, and relay alarm output. The instrument adopts high-performance microprocessors and high-precision AD chips, which have the characteristics of high stability, beautiful appearance, and good electromagnetic compatibility&lt;BR&gt;&lt;BR&gt;Technical parameters of PK-I series programmable ammeter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;input signal&lt;/TD&gt;
&lt;TD&gt;Communicate 45~65Hz current signal, 0~10A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;input impedance&lt;/TD&gt;
&lt;TD&gt;&amp;lt;10m次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;sampling rate&lt;/TD&gt;
&lt;TD&gt;4000 times per second&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;permitted Overload &lt;/TD&gt;
&lt;TD&gt;1.2 times the range&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;measurement accuracy&lt;/TD&gt;
&lt;TD&gt;Superior to level 0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;display mode&lt;/TD&gt;
&lt;TD&gt;4-digit 0.36/0.56/0.8 inch high brightness LED digital display&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Display magnification&lt;/TD&gt;
&lt;TD&gt;1 to 2000 can be set&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Display updates&lt;/TD&gt;
&lt;TD&gt;About 3 times per second&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working power supply&lt;/TD&gt;
&lt;TD&gt;AC220V &#177; 10%, power consumption&amp;lt;2W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working environment&lt;/TD&gt;
&lt;TD&gt;Temperature: -10 ⊥ to 50 ⊥; Humidity: 20% to 90% (no condensation).&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Optional features&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;communication interface&lt;/TD&gt;
&lt;TD&gt;Two line RS485 communication, standard MODBUS-RTU communication protocol&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;transmitter output&lt;/TD&gt;
&lt;TD&gt;DC 4-20mA (load resistance ≒ 300 次)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control/alarm output&lt;/TD&gt;
&lt;TD&gt;2-channel lower limit relay open circuit output, contact capacity: AC240/7A, DC28V/10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;PK-I Series Programmable Ammeter Selection Table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=10&gt;Model number&lt;/TD&gt;
&lt;TD colSpan=2&gt;Explanation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;↓↓↓I&lt;/TD&gt;
&lt;TD&gt;↓&lt;/TD&gt;
&lt;TD colSpan=2&gt;↓&lt;/TD&gt;
&lt;TD colSpan=2&gt;↓&lt;/TD&gt;
&lt;TD colSpan=2&gt;↓&lt;/TD&gt;
&lt;TD colSpan=3&gt;Programmable intelligent ammeter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;F48I&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;↓&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;48*48mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;B96I&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;48*96 mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;F96I&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;96*96 mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;B80I&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;80*160mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=3&gt;RS-485 communication&lt;/TD&gt;
&lt;TD colSpan=2&gt;0&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;No communication interface&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;one&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;RS-485 interface&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=5&gt;transmitter output&lt;/TD&gt;
&lt;TD colSpan=2&gt;0&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;No transmitter output&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;one&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;4-20mA transmission output&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=7&gt;alarm output&lt;/TD&gt;
&lt;TD colSpan=2&gt;0&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;No alarm output&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;one&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;Relay alarm output&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=9&gt;input range &lt;/TD&gt;
&lt;TD&gt;X&lt;/TD&gt;
&lt;TD colSpan=2&gt;0-15A current input&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[ammeter]51C4-A DC ammeter </title>
           <link>http://www.91way.com/info_en/23636.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:52:05</pubDate>
           <comments></comments>
           <description>51C4-A DC ammeter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]51C6-A DC ammeter </title>
           <link>http://www.91way.com/info_en/23635.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:56</pubDate>
           <comments></comments>
           <description>51C6-A DC ammeter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]61C13-A DC ammeter </title>
           <link>http://www.91way.com/info_en/23633.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:48</pubDate>
           <comments></comments>
           <description>61C13-A DC ammeter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]SWB-III type digital microampere meter </title>
           <link>http://www.91way.com/info_en/23419.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:39</pubDate>
           <comments></comments>
           <description>The SWB-III digital microampere meter is a precision instrument used to measure the DC withstand voltage leakage of high-voltage electrical appliances or insulation materials, and is the most ideal match for various types of high-voltage test transformers. Used for measuring DC leakage current or conductivity current values, it can be used in conjunction with DC high-voltage generators and various test transformers. The digital microampere meter is an indispensable DC ammeter for measuring the DC withstand voltage and leakage current of high-voltage electrical appliances or insulation materials under test.&lt;BR&gt;&lt;BR&gt;The SWB-III digital microampere meter is mainly used as a precision instrument for DC testing of DC high-voltage generators and high-voltage test transformers, and is the most ideal instrument tool for testing DC high-voltage leakage current. &lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;1. Measurement accuracy: 1%;&lt;BR&gt;2. Range: 2000 米 A; &lt;BR&gt;3. Measurement range: 0~199.9uA~1999.9uA Automatic shifting or 0~1999.9uA~1999.9uA Automatic shifting&lt;BR&gt;4. Resolution: 0.1 uA or 0.01 uA&lt;BR&gt;5. Accuracy: Level 0.5&lt;BR&gt;6. Working power supply: 9V (stacked battery)&lt;BR&gt;7. Working environment: Environmental temperature: 0-40 ⊥ Environmental humidity:&amp;lt;85%&lt;BR&gt;8. Display method: Display a 4-digit specially designed large LCD digital display meter&lt;BR&gt;9. Full shielding: The case is elliptical in shape with a diameter of 朴 130mm &#215; 60mm, and is made of lightweight metal that has undergone surface treatment. The display window is made of conductive glass, ensuring complete shielding of the measurement system.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC5-5/8 DC galvanometer </title>
           <link>http://www.91way.com/info_en/23401.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:31</pubDate>
           <comments></comments>
           <description>The AC5-5/8 DC ammeter can be used as a DC potential difference meter, a high-sensitivity ammeter for external connections such as DC bridges, or directly as an ammeter. The internal resistance is the sampling resistance inside the meter, with an error of less than &#177; 5%. The AC-8 type includes all functions of AC5-1 to AC5-7.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;Current constant (A/grid)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;Damping time&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;2&#215;10&lt;SUP&gt;-5&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;1mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=8 width=&quot;24%&quot;&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;≒ 2 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;-6&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;300米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;2&#215;10&lt;SUP&gt;-6&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;100米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;-7&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;30米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;2&#215;10&lt;SUP&gt;-7&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;10米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-6&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;-8&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;3米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;-8&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;1米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;AC5-8&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;
&lt;P align=center&gt;5&#215;10&lt;SUP&gt;-5&lt;/SUP&gt;-5&#215;10&lt;SUP&gt;-8&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;&#177;1米A-&#177;1mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;AC5-5/8 DC galvanometer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]SK-300 series intelligent voltmeter and ammeter </title>
           <link>http://www.91way.com/info_en/18639.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:22</pubDate>
           <comments></comments>
           <description>The SK-300 series intelligent voltmeter and ammeter are controlled and operated by microprocessors, and can meet the requirements of various measurement ranges with different transformers. They can display, control, and transmit voltage and current with high precision.&lt;BR&gt;&lt;BR&gt;Functional Features&lt;BR&gt;Multiple protection, isolation design, strong anti-interference ability, high reliability&lt;BR&gt;A good software platform with secondary development capabilities to meet special functional requirements&lt;BR&gt;Capable of self calibration, manual calibration, and sensor correction&lt;BR&gt;Complete network communication function, bidirectional communication with various devices with serial input/output, forming a network control system&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]CT1 type flux meter </title>
           <link>http://www.91way.com/info_en/18385.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:14</pubDate>
           <comments></comments>
           <description>CT1 type magnetic flux meter:&lt;BR&gt;&lt;BR&gt;Measuring range:&lt;BR&gt;When the measuring coil is one turn, the total deflection is 10 milliradians.&lt;BR&gt;Basic error:&lt;BR&gt;When the resistance of the measuring coil is below 8 次, it should not exceed &#177; 2.5%. When the resistance is 20 次, it should not exceed &#177; 4%.&lt;BR&gt;&lt;BR&gt;The basic error of the instrument is expressed as a percentage of the measurement upper limit.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]MG21 AC/DC ammeter </title>
           <link>http://www.91way.com/info_en/18371.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:51:05</pubDate>
           <comments></comments>
           <description>MG21 AC/DC ammeter:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;28%&quot;&gt;AC and DC currents&lt;/TD&gt;
&lt;TD width=&quot;72%&quot;&gt;0-750Aㄛ0-1000Aㄛ0-1500A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;measurement accuracy&lt;/TD&gt;
&lt;TD&gt;≒&#177;5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working conditions&lt;/TD&gt;
&lt;TD&gt;-20&#176;C~+50&#176;C r.h≒85%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation test&lt;/TD&gt;
&lt;TD&gt;50Hz 2000V per.1.min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Damping time&lt;/TD&gt;
&lt;TD&gt;≒4s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Overall dimensions&lt;/TD&gt;
&lt;TD&gt;308&#215;107&#215;70ㄗmmㄘ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Weight:&lt;/TD&gt;
&lt;TD&gt;1.5kg&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]MG20 type AC/DC ammeter </title>
           <link>http://www.91way.com/info_en/18370.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:56</pubDate>
           <comments></comments>
           <description>MG20 AC/DC ammeter:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;23%&quot;&gt;AC and DC currents&lt;/TD&gt;
&lt;TD width=&quot;77%&quot;&gt;0-200Aㄛ0-400Aㄛ0-600A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;measurement accuracy&lt;/TD&gt;
&lt;TD&gt;≒&#177;5%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working conditions&lt;/TD&gt;
&lt;TD&gt;-20&#176;C~+50&#176;C r.h≒85%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation test&lt;/TD&gt;
&lt;TD&gt;50Hz 2000V per.1.min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Damping time&lt;/TD&gt;
&lt;TD&gt;≒4s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Overall dimensions&lt;/TD&gt;
&lt;TD&gt;308&#215;107&#215;70ㄗmmㄘ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Weight:&lt;/TD&gt;
&lt;TD&gt;1.5kg&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]MS-500P Distribution Network Capacitive Current Measuring Instrument </title>
           <link>http://www.91way.com/info_en/17907.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:48</pubDate>
           <comments></comments>
           <description>MS-500P type distribution network capacitor current tester. This new intelligent tester directly measures the capacitance current of the distribution network from the secondary side of the PT. Compared with traditional testing methods, this instrument does not need to deal with the primary side, so there is no risk of testing. There is no need to take complicated safety measures or wait for lengthy scheduling commands. Simply connect the measurement line to the open triangular end of the PT to measure the capacitance current data. Due to the injection of weak out of frequency test signals from the PT opening triangle, it will not have any impact on the relay protection and PT itself, and avoids 50Hz power frequency interference signals. At the same time, the output terminal of the tester can withstand 100V AC voltage. If a single-phase ground fault occurs during measurement, it will not damage the PT and tester. Therefore, no special safety measures are needed, making this work safe, simple, fast, and the test results accurate, stable, and reliable. The tester adopts a large screen LCD display and a Chinese menu, which is very easy to operate. It is small in size, light in weight, and easy to carry for outdoor operations. The wiring is simple, the testing speed is fast, and the data accuracy is high, greatly reducing the labor intensity of the tester and improving the work efficiency (suitable for capacitor current testing of 6-35kV distribution systems). &amp;nbsp;&lt;BR&gt;&lt;BR&gt;technical indicators&lt;BR&gt;&lt;BR&gt;Scope of application: 6kV~35kV system&lt;BR&gt;Measurement range: 0-500A; 0-250 米 F&lt;BR&gt;Measurement accuracy: &#177; 5% (when the capacitance current is between 10A and 500A) &#177; 1A (when the capacitance current is less than 10A)&lt;BR&gt;Power supply: AC220V &#177; 10%&lt;BR&gt;Power frequency: 50Hz &#177; 1%&lt;BR&gt;Environmental temperature: 0 ⊥~45 ⊥&lt;BR&gt;Relative humidity: ≒ 90%&lt;BR&gt;&lt;BR&gt;Functional Features&lt;BR&gt;&lt;BR&gt;Scope of application: 6kV~35kV system&lt;BR&gt;Measurement range: 0-500A; 0-250 米 F&lt;BR&gt;Measurement accuracy: &#177; 5% (when the capacitance current is between 10A and 500A) &#177; 1A (when the capacitance current is less than 10A)&lt;BR&gt;Power supply: AC220V &#177; 10%&lt;BR&gt;Power frequency: 50Hz &#177; 1%&lt;BR&gt;Environmental temperature: 0 ⊥~45 ⊥&lt;BR&gt;Relative humidity: ≒ 90%&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]FZY-3 Mining stray current measuring instrument </title>
           <link>http://www.91way.com/info_en/17905.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:39</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;FZY-3 mining stray current measuring instrument is used to test the stray current of steel rails, cable sheaths, metal grids, etc. in underground coal mines. Prevent stray current from exceeding the specified value and causing electric sparks. Ensure the safety of the mine.&lt;BR&gt;&lt;BR&gt;measurement range&lt;BR&gt;&lt;BR&gt;Communication mode: 0~100mA~500mA~1A~5A&lt;BR&gt;DC mode: (+) 0~100mA~500mA~2.5A~10A~50A&lt;BR&gt;Its original error: DC gear+2.5%&lt;BR&gt;Communication file+5%&lt;BR&gt;&lt;BR&gt;Precautions for FZY-3 Mining Stray Current Tester&lt;BR&gt;&lt;BR&gt;Before measurement, insert the test line into the internal test line hole respectively, and insert both ends of the connecting wire into the two sockets respectively, adjust the pointer of the meter head to make it indicate the zero line.&lt;BR&gt;Place the test rods connected to the terminal posts at the two points being tested (such as steel rails, cable sheaths, coal, etc.) and set the switch to the appropriate position. The indicated value on the meter head is the stray current value between the two points being tested. When the pointer turns right, it is positive, and when it turns left, it is negative.&lt;BR&gt;When measuring stray voltage, the connection in the two-color column can be forked, and the meter head indicates the voltage value, with mA corresponding to mV and A corresponding to V.&lt;BR&gt;When the unknown stray current is large, it should be set to the maximum range first, and then gradually reduced until it reaches the appropriate measurement range. The instrument should be placed horizontally.&lt;BR&gt;When the measured current is greater than 5A, the instrument should only perform short-term measurements. When the measured current is greater than 10A, only instantaneous measurements can be performed.&lt;BR&gt;The instrument should be placed in the (off) position when not in use.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]YJ110 Milliampere direct reading calibrator </title>
           <link>http://www.91way.com/info_en/16881.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:31</pubDate>
           <comments></comments>
           <description>YJ110mAh direct reading calibrator&lt;BR&gt;Verification range: 10 米 A~22mA (all with output) Display mode: 4&lt;SUP&gt;one&lt;/SUP&gt;/&lt;SUB&gt;two&lt;/SUB&gt;LCD accuracy: 0.1%&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]JZ3 electronic current detector </title>
           <link>http://www.91way.com/info_en/16660.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:22</pubDate>
           <comments></comments>
           <description>JZ3 electronic current detector&lt;BR&gt;&lt;BR&gt;Current constant&amp;lt;3 * 10-9A/division; There is a protective circuit, and the sensitivity is continuously adjustable&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AZ19 DC galvanometer </title>
           <link>http://www.91way.com/info_en/16659.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:13</pubDate>
           <comments></comments>
           <description>The AZ19 DC galvanometer is used as an external high-sensitivity galvanometer for DC potentiometers, DC bridges, etc. It can also be used as a low-noise and low drift DC amplifier and DC voltmeter.&lt;BR&gt;Range: &#177; 30 米 V, &#177; 100 米 V, &#177; 300 米 V, non-linear, &#177; mV, &#177; 10mV, &#177; 30mV&lt;BR&gt;Input impedance: ≡ 10K 次&lt;BR&gt;Voltage constant: minimum 0.5V/grid&lt;BR&gt;Current constant: minimum 0.05 * 10-9A/grid&lt;BR&gt;Zero voltage drift: ≒ 2.5V/4 hours&lt;BR&gt;Replace AC15 spot complex galvanometer&lt;BR&gt;&lt;BR&gt;AZ19 DC galvanometer external dimensions: 170 * 160 * 230mm&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Voltage constant&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;response time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;30米v&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.5米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(20&#177;2)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;100米v&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;2米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(20&#177;2)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;300米v&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;5米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(20&#177;2)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;nonlinear&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.5米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;&lt;/TD&gt;
&lt;TD width=120&gt;&lt;/TD&gt;
&lt;TD width=166&gt;
&lt;P align=center&gt;Voltage constant refers to the value near zero point&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;1mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;20米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(200&#177;20)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;3mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;50米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(200&#177;20)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;10mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;200米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;(200&#177;20)k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;&#177;30mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;500米V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;2M次&#177;200k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;3S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1622A AC 0.5 level current timer </title>
           <link>http://www.91way.com/info_en/15783.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:50:05</pubDate>
           <comments></comments>
           <description>ZW1622A AC 0.5 level current timer&lt;BR&gt;&lt;BR&gt;Measurement item: AC (15mA~15A) Time (maximum 9999 hours)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 5 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC (85V-265V)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 300g&lt;BR&gt;&lt;BR&gt;Expansion options&lt;BR&gt;RS-485/232 data communication (ModBus protocol)&lt;BR&gt;Relay alarm output&lt;BR&gt;Analog output (0-5V or 1-10V or 4-20mA or 0-20mA)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]YD2611/11A/11C Electrolytic capacitor leakage current measuring instrument </title>
           <link>http://www.91way.com/info_en/13967.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:56</pubDate>
           <comments></comments>
           <description>YD2611/11A/11C electrolytic capacitor leakage current measuring instrument features:&lt;BR&gt;&lt;BR&gt;High charging current and fast charging speed&lt;BR&gt;Digital display of test voltage and charging time&lt;BR&gt;Easy to operate and reliable in work&lt;BR&gt;Universal testing instrument on the production line&lt;BR&gt;&lt;BR&gt;Technical parameters:&lt;BR&gt;&lt;BR&gt;Test voltage: YD2611 0-50V/100V/200V&lt;BR&gt;YD2611A 0-100V/200V/500V&lt;BR&gt;YD2611C 0-200V/500V/1000V&lt;BR&gt;Voltage accuracy: 2%&lt;BR&gt;Current measurement range: 0-30mA&lt;BR&gt;Current accuracy: 2%&lt;BR&gt;Maximum charging current: YD2611/11A 400mA&lt;BR&gt;YD2611C 200mA&lt;BR&gt;Charging time: 0-99s&lt;BR&gt;Display mode: voltage and time digital display, leakage current pointer display&lt;BR&gt;Sorting: qualified, unqualified sound&lt;BR&gt;Dimensions: 380 &#215; 140 &#215; 320 (mm)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]YD2611D electrolytic capacitor leakage current measuring instrument </title>
           <link>http://www.91way.com/info_en/13966.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:48</pubDate>
           <comments></comments>
           <description>Characteristics of YD2611D electrolytic capacitor leakage current measuring instrument:&lt;BR&gt;&lt;BR&gt;Automatic cycle testing&lt;BR&gt;Voltage and current digital display&lt;BR&gt;Charging countdown indicator&lt;BR&gt;Bottom zero reset function&lt;BR&gt;Technical parameters:&lt;BR&gt;Test voltage: 0-500V&lt;BR&gt;Voltage resolution: 0.1V&lt;BR&gt;Voltage accuracy: 1%&lt;BR&gt;Current measurement range: 10 米 A-20mA&lt;BR&gt;Maximum charging current: 200mA&lt;BR&gt;Control mode: automatic testing/manual testing&lt;BR&gt;Display mode: voltage, leakage current, time digital display&lt;BR&gt;Sorting: qualified/unqualified indication, unqualified sound&lt;BR&gt;Dimensions: 380 &#215; 140 &#215; 320 (mm)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]XPX116C Dual channel current calibrator </title>
           <link>http://www.91way.com/info_en/13890.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:39</pubDate>
           <comments></comments>
           <description>The XPX116C process signal calibrator is a handheld field specific calibrator that can simultaneously simulate and measure DC process signals. It has automatic range control in mA and V ranges, input/output isolation, and a four and a half digit LCD display. It can simulate and test most analytical instrument signals and is suitable for verifying various parameters on site in chemical, electrical, and other systems.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;scope&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=203&gt;
&lt;P align=center&gt;accuracy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=36&gt;
&lt;P align=center&gt;input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;200mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;10&amp;micro;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=203&gt;
&lt;P align=center&gt;&#177;(0.05%FS+0.01%RDG+1LSD)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;20V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;1mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=203&gt;
&lt;P align=center&gt;&#177;(0.05%FS+0.01%RDG+1LSD)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;P align=center&gt;automatic control&lt;/P&gt;
&lt;P align=center&gt;Measuring range&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;200V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;10mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;20mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;1&amp;micro;A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;100mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=36&gt;
&lt;P align=center&gt;output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;110.00mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;10&amp;micro;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=203&gt;
&lt;P align=center&gt;&#177;(0.05%FS+0.01%RDG+1LSD)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;11.000V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;1mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;20.000mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;1&amp;micro;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;P align=center&gt;automatic control&lt;/P&gt;
&lt;P align=center&gt;Measuring range&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;20-24.00mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Input impedance: mV&amp;gt;10M 次, V&amp;gt;1M 次, mA approximately&amp;gt;10 次&lt;BR&gt;Output impedance: mV about 0.5 次, V about 2 次, mA500 次 load&lt;BR&gt;Stability: short-term 24-hour &#177; 1LSD, long-term 30 day &#177; 2LSD&lt;BR&gt;Output noise: less than 1LSD&lt;BR&gt;Input/output isolation: 200V DC&lt;BR&gt;Working temperature: 0-40 ⊥&lt;BR&gt;Environmental temperature impact: &#177; 0.01% FS/⊥&lt;BR&gt;Usage time after charging: 20mA output continuously for about 6 hours or more&lt;BR&gt;Low battery indicator: &quot;LOW BATTERY&quot;&lt;BR&gt;Display: Four and a half digit LCD display data&lt;BR&gt;Dimensions: 170 &#215; 84 &#215; 50mm&lt;BR&gt;Weight: Approximately 1kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]XPX116B On site DC current verification signal generator </title>
           <link>http://www.91way.com/info_en/13889.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:31</pubDate>
           <comments></comments>
           <description>XPX116B voltage and current source, capable of outputting 0-2400mA, 0-111000V, 0-110.00mV. Suitable for on-site verification and use in popular departments such as electricity and chemical industry.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 85%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;85%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Output range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;scope&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;accuracy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0-110.00mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;10&amp;micro;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0-11.000V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;1mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0-24.00mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+2LSD)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Input impedance: mV approximately 0.5 次, V approximately 2 次, mA approximately 10 次&lt;BR&gt;Output noise: less than 1LSD&lt;BR&gt;Working temperature: 5-40 ⊥&lt;BR&gt;Environmental temperature impact: &#177; 0.01% FS/⊥&lt;BR&gt;Charging time and usage time: Charging for 14-16 hours is sufficient, and continuous output of 20mA can be used for more than 4 hours&lt;BR&gt;Low battery indicator: &quot;LOW BATTERY&quot;&lt;BR&gt;Display: Four and a half digit LCD display data&lt;BR&gt;Dimensions: 170 &#215; 84 &#215; 50mm&lt;BR&gt;Weight: Approximately 1kg&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]XPX116 Dual channel current calibrator </title>
           <link>http://www.91way.com/info_en/13888.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The XPX116 on-site DC current verification signal generator is a handheld instrument that can measure and generate 0-24mA DC current signals. The instrument is equipped with a 4 1/2 LCD display with a display accuracy of 0.1%. The instrument is compact in size, easy to carry, and comes with a built-in battery that can be recharged repeatedly. It is particularly suitable for the calibration, testing, and maintenance of two-wire 4-20mA instruments and control systems. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Usage conditions&lt;BR&gt;Environmental temperature: 0-+50 ⊥&lt;BR&gt;Relative humidity of the environment: below 85%&lt;BR&gt;Power supply: (DC) 9.6-12V&lt;BR&gt;&lt;BR&gt;Basic error of XPX116 dual channel current calibrator&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 85%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;85%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Test current range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Output current range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;basic error&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=120&gt;
&lt;P align=center&gt;0-24mA&lt;/P&gt;
&lt;P align=center&gt;ㄗ-25%〞+125%ㄘ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Fixed range: 4mA (0%)&lt;/P&gt;
&lt;P&gt;20mAㄗ100%ㄘ&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=108&gt;
&lt;P align=center&gt;0.1% FS &#177; 1 word&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=168&gt;
&lt;P&gt;Continuous range: 0-24mA&lt;/P&gt;
&lt;P&gt;ㄗ-20%〞+125%ㄘ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;load capacity&lt;BR&gt;When powered externally, the maximum DC supply voltage is 45V; when powered by an internal battery, the maximum load of 20mA is 750 次. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Low voltage display of power supply&lt;BR&gt;Under internal power supply, when the load is 100 次 and the output current is 26mA, the LCD displays &quot;LOW BATTERY&quot;, and the power supply voltage is between 9.55V and 9.2V. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;temperature effect&lt;BR&gt;When the ambient temperature of the product deviates from the reference conditions by 20 &#177; 2 ⊥, the temperature effect is 0.2% FS/10 ⊥. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;display&lt;BR&gt;4 1/2 LCD display with a resolution of 0.01mA or 0.01%.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]XPX116A type dual channel current calibrator </title>
           <link>http://www.91way.com/info_en/13886.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:13</pubDate>
           <comments></comments>
           <description>The XPX116A dual channel current calibrator is a handheld field calibrator that can simultaneously simulate and measure DC current signals, with S input/output isolation. Non regulated 24V DC voltage output can display circuit current. Suitable for on-site verification of various current parameters in petroleum, chemical, power and other systems. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;scope&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;accuracy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;&#177;50.00mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=144&gt;
&lt;P align=center&gt;&#177; (0.05%RDG&lt;/P&gt;
&lt;P align=center&gt;+0.05%FS+1LSD)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=58&gt;
&lt;P align=center&gt;output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;20.00mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-24mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;
&lt;P align=center&gt;Output 24V circuit current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-30mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;10&amp;micro;A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Input mA impedance: mA approximately 10 次&lt;BR&gt;Output 24V load: 20mA (non regulated)&lt;BR&gt;Stability: short-term 24-hour &#177; 1LSD, long-term 20 day &#177; 2LSD&lt;BR&gt;Output noise: less than 1LSD&lt;BR&gt;Input/book coarse isolation: 200V DC&lt;BR&gt;Working temperature: 5-40 ⊥&lt;BR&gt;Environmental temperature impact: 0.01% FS/⊥&lt;BR&gt;Usage time after charging: 20mA output for about 8 hours&lt;BR&gt;Low battery indicator: &quot;LOW BATTERY&quot;&lt;BR&gt;Display: Four and a half digit LCD display data&lt;BR&gt;Dimensions: 170 &#215; 84 &#215; 50mm&lt;BR&gt;Weight: Approximately 1kg&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]PA15A type DC digital ammeter </title>
           <link>http://www.91way.com/info_en/13859.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:49:05</pubDate>
           <comments></comments>
           <description>The PA15A DC digital ammeter is a portable instrument that uses a 4 1/2 CMOS large-scale integrated circuit. Its measurement results are displayed using a six bit LED and have a measurement result retention function. This meter has the characteristics of low power consumption, high resolution, good reliability, strong adaptability, and easy use. It can be combined with various sensors or converters to easily achieve digital measurement of various electrical and non electrical quantities. It is an ideal instrument for laboratory and industrial field testing.&lt;BR&gt;&lt;BR&gt;Technical data of PA15A DC digital ammeter&lt;BR&gt;Range, measurement range, resolution, and basic error: Under reference conditions, the basic error of the product meets the specifications in the table below.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 85%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;85%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;internal resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;Basic error&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;200米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;0-199.99米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;0.01米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;1k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;2mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;0-1.9999mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;0.1米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;100次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;20mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;0-19.999mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;1米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;10次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.05%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;200mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;0-199.99mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;10米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;1次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.06%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=56&gt;
&lt;P align=center&gt;2A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;P align=center&gt;0-1.9999A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;100米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;0.1次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;P align=center&gt;&#177;(0.08%RD+0.02%FS)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Measurement speed: 2-3 times/second&lt;BR&gt;Environmental temperature: 0-40 ⊥&lt;BR&gt;Relative humidity: below 80%&lt;BR&gt;Power supply: 220V 50Hz&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]SB15 type panel type series AC digital ammeter </title>
           <link>http://www.91way.com/info_en/13845.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:56</pubDate>
           <comments></comments>
           <description>The SB15 panel type series AC digital ammeter is a small and popular instrument with a 4/2 CMOS large-scale integrated circuit, and its measurement results are displayed using a five digit LED. This meter has the characteristics of small size, low power consumption, high sensitivity, good reliability, excellent performance, strong adaptability, and easy use. When combined with various sensors or converters, it can easily achieve digital measurement of various electrical and non electrical quantities. It is a supporting instrument for various measuring instruments and control consoles.&lt;BR&gt;&lt;BR&gt;Technical data of SB15 panel series AC digital ammeter&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;Environmental temperature: 0-+40 ⊥&lt;BR&gt;Relative temperature of the environment: below 80%&lt;BR&gt;Power supply: 220 &#177; 22V, 50 &#177; 1.5Hz&lt;BR&gt;&lt;BR&gt;Specification, measurement range, resolution, and basic error: The basic error of the product under reference conditions should comply with the provisions in the table below.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=43&gt;
&lt;P align=center&gt;correspond to&lt;/P&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=47&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=196 colSpan=2&gt;
&lt;P align=center&gt;basic error&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;50Hz-1kHz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;50Hz-500Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SB15/12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;200米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-199.99米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;10nA&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=82&gt;
&lt;P align=center&gt;&#177; (0.2% reading+10 words)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SB15/13&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;2mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-1.9999mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;100nA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SB15/14&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;20mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-19.999mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;1米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SB15/15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;200mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-199.99mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;10米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;&#177; (0.2% reading+10 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SB15/16&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;2A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0-1.9999A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;100米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;P align=center&gt;&#177; (0.35% reading+10 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Weight: 0.6kg&lt;BR&gt;Dimensions: 48 &amp;acute; 110 &amp;acute; 112mm&lt;BR&gt;Hole size: 44'95mm&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]PZ158AB series DC digital voltmeter and ammeter </title>
           <link>http://www.91way.com/info_en/13838.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:48</pubDate>
           <comments></comments>
           <description>The PZ158AB series DC digital voltage and current meter is a high-precision electronic measuring instrument with a 6 half bit word length, 0.1 米 V voltage resolution, and 0.1 &amp;micro; A current resolution, equipped with single-chip microcomputer technology. Due to the use of advanced single-chip microcontrollers and precise analog-to-digital conversion technology, this series of instruments can automatically calibrate and effectively filter digital signals at regular intervals, thereby endowing the instruments with extremely stable zero positions, excellent reading linearity, and strong anti-interference capabilities. This series of instruments adopts an eight digit LED display, which is soft and eye-catching. The excellent performance of this series of instruments can play a significant role in fields such as scientific research, industry, agriculture, and national defense. This series of instruments comes with an RS232C interface output, which can be directly connected to a computer with a serial port to form a testing system.&lt;BR&gt;technical indicators&lt;BR&gt;&lt;BR&gt;Range: 200mV-200V (4th gear), 200mA&lt;BR&gt;Basic error: 0.0025% -0.003% (V), 0.008% (A)&lt;BR&gt;Highest resolution: 0.1 米 V, 0.1 米 A&lt;BR&gt;Measurement speed: 1.2 times/second&lt;BR&gt;Dimensions: 88 &#215; 235 &#215; 360mm&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]DP4-A Four and a half digit ammeter </title>
           <link>http://www.91way.com/info_en/11721.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:39</pubDate>
           <comments></comments>
           <description>Four and a half digit voltmeter and ammeter&lt;BR&gt;&lt;BR&gt;Model: DP4-AA, DA&lt;BR&gt;Working power supply: AC220V, AC24V, AC110V, DC5V, DC12V, DC24V optional&lt;BR&gt;&lt;BR&gt;Basic range: DC/AC 200uA-5A (direct input)&lt;BR&gt;Equipped with AC transformer capable of measuring 5A-2000A&lt;BR&gt;Equipped with a DC splitter, it can measure 5A-2000A&lt;BR&gt;Display font height: 0.56※&lt;BR&gt;Display mode: Red and blue LED optional&lt;BR&gt;Maximum display: &#177; 19999&lt;BR&gt;Accuracy: &#177; (0.2%+2 words)&lt;BR&gt;Dimensions: 48 &#215; 96 &#215; 60 (mm)&lt;BR&gt;Hole size: 45 &#215; 92 (mm)&lt;BR&gt;Product features: Exquisite and beautiful fully enclosed shell, embedded installation, strong anti-interference&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]DP3-A Three and a half digit ammeter </title>
           <link>http://www.91way.com/info_en/11720.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:31</pubDate>
           <comments></comments>
           <description>Three and a half digit voltmeter and ammeter&lt;BR&gt;&lt;BR&gt;Model: DP3-AA, DA&lt;BR&gt;Working power supply: AC220V, AC24V, AC110V, DC5V, DC12V, DC24V optional&lt;BR&gt;Basic range: DC/AC 200uA-5A (direct input)&lt;BR&gt;Equipped with AC transformer capable of measuring 5A-2000A&lt;BR&gt;Equipped with a DC splitter, it can measure 5A-2000A&lt;BR&gt;&lt;BR&gt;Display font height: 0.56※&lt;BR&gt;Display mode: Red and blue LED optional&lt;BR&gt;Maximum display: &#177; 1999&lt;BR&gt;Accuracy: &#177; (0.2%+2 words)&lt;BR&gt;Dimensions: 48 &#215; 96 &#215; 60 (mm)&lt;BR&gt;Hole size: 45 &#215; 92 (mm)&lt;BR&gt;Product features: Exquisite and beautiful fully enclosed shell, embedded installation, strong anti-interference, adjustable panel zero position, adjustable panel display ratio&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]T69-A Electromagnetic AC Ampere Meter </title>
           <link>http://www.91way.com/info_en/11165.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:22</pubDate>
           <comments></comments>
           <description>Model: T69-A&lt;BR&gt;Product: AC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Quantity limit: 0-0.5-2-5-10-25-50A 0-2.5-5-10-250A 0-2.5-5-10-25-50-100A&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Dimensions: 210x152x90mm&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;The attached CP wire structure ruler has a length of 110mm and a working frequency of 45-65Hz, which can replace the T19 instrument&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]T63-mA-A Electromagnetic Medium Frequency AC/DC Milliampere Meter </title>
           <link>http://www.91way.com/info_en/11163.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:14</pubDate>
           <comments></comments>
           <description>Model: T63-mA&lt;BR&gt;Product: Medium frequency AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Quantity limit: 0-50-100mA, 0-100-200mA, 0-250-500mA&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Model: T63-A&lt;BR&gt;Product: Intermediate frequency AC/DC ammeter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Limit: 0-0.5-1A 0-1-2A 0-2.5-5A 0-5-10A&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Dimensions: 210x152x90mm&lt;BR&gt;Features and uses: Tensioning mechanism instrument, ruler length 110mm, weight ≒ 2kg, working frequency 45-65Hz, 90-1500Hz. The product can be used as a standard gauge and can replace T19, T22, T10, T15, T29, T32, D26, T80&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]T77-mA-A Electromagnetic AC/DC Milliampere Meter </title>
           <link>http://www.91way.com/info_en/11162.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:48:05</pubDate>
           <comments></comments>
           <description>T77-mA-A Electromagnetic AC/DC Milliampere Meter&lt;BR&gt;&lt;BR&gt;Model: T77 mA&lt;BR&gt;Product: AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Rated current (A): 0-10-20-40mA 0-50-100-200mA 0-250-500-1000mA&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Model: T77-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Technical specifications of T77-mA-A electromagnetic AC/DC milliampere meter:&lt;BR&gt;&lt;BR&gt;Rated current (A): 0-0.5-1A 0-1-2A 0-2.5-5A 0-5-10A&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Dimensions: 210x152x90mm&lt;BR&gt;Features and Applications: Wire tensioning mechanism instrument, aluminum pointer, ruler length 135mm, weight ≒ 2kg, working frequency 45-65Hz&lt;BR&gt;replaceable T19﹜T22﹜T10﹜T15﹜T29﹜T32﹜D26﹜T81﹜T75﹜T56﹜T31﹜T55﹜T21﹜T23&lt;BR&gt;T77 ammeter can be connected to HL55, HL36 current transformers with expandable limit of 600A-2000A&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]T51-mA-A Electromagnetic AC/DC Milliampere Meter </title>
           <link>http://www.91way.com/info_en/11159.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:57</pubDate>
           <comments></comments>
           <description>T51-MA-A Electromagnetic AC/DC Milliampere Meter&lt;BR&gt;&lt;BR&gt;Model: T51-mA&lt;BR&gt;Product: AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Rated current (A): 0-10-20-40mA 0-50-100-200mA 0-250-500-1000mA&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: T51-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Technical specifications of T51-mA-A electromagnetic AC/DC milliampere meter:&lt;BR&gt;&lt;BR&gt;Rated current (A): 0-0.5-1A 0-1-2A 0-2.5-5A 0-5-10A&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: T51-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Rated current (A): 0-20A 0-30A&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: T51-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Rated current (A): 0-50A 0-100A&lt;BR&gt;Number of dials: 150&lt;BR&gt;&lt;BR&gt;Dimensions: 210x152x90mm&lt;BR&gt;Features and uses: Tensioning mechanism instrument, ruler length 110mm, weight ≒ 2kg, working frequency 45-65Hz, product can be used as a standard meter, original T2 type instrument&lt;BR&gt;replaceable T19﹜T22﹜T10﹜T15﹜T29﹜T32﹜D26﹜T81﹜T75﹜T56﹜T31﹜T55﹜T21﹜T23&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]C79-A DC Ampere Meter </title>
           <link>http://www.91way.com/info_en/11156.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:48</pubDate>
           <comments></comments>
           <description>Model: C79-A/1-2&lt;BR&gt;&lt;BR&gt;Product: DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Quantity limit: 0-0.015-0.03-0.075-0.15-0.3-0.75-0.5-3-7.5-15-30A&lt;BR&gt;&lt;BR&gt;Size: 290x200x120mm can replace C41&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;The length of the gauge of the wire structure instrument is 160mm, the weight is ≒ 4kg, the instrument weight limit consumes 1mA of current, and the original C4 type instrument&lt;BR&gt;&lt;BR&gt;C79/1 is at level 0.5&lt;BR&gt;C79/2 is at level 0.2&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]0.5 type DC micro milliampere meter (0.5 level multi limit) </title>
           <link>http://www.91way.com/info_en/11154.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:40</pubDate>
           <comments></comments>
           <description>Model: C77uA&lt;BR&gt;&lt;BR&gt;Product; DC microampere meter&lt;BR&gt;&lt;BR&gt;Main indicators:&lt;BR&gt;quantifier uAㄩ0-10-20-50米A. 0-50-100-200米A. 0-200-500-1000米A. 0-50-100-200-500-1000米A.&lt;BR&gt;&lt;BR&gt;0-10-20-50-100-200-500-1000米A.&lt;BR&gt;&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: C77mA&lt;BR&gt;Product: DC milliampere meter&lt;BR&gt;Main indicators:&lt;BR&gt;quantifier mAㄩ0-0.5-1-2mA. 0-0.5-1-2-5-10mA. 0-5-10-20mA. 0-50-100-200mA. 0-10-20-50-100-200mA. 0-100-200-500-1000mA&lt;BR&gt;&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: C77A&lt;BR&gt;Product: DC Ampere Meter&lt;BR&gt;Main indicators:&lt;BR&gt;Limit A: 0-1-2-5-10-20A. 0-1.5-3-7.5-15-30A&lt;BR&gt;0-0.0005(45mv)-0.001-0.002-0.005-0.01-0.02-0.05-0.1-0.2-0.5-1-2-5-10-20A.&lt;BR&gt;0-0.00075(45mv)-0.0015-0.003-0.0075-0.015-0.03-0.075-0.15-0.3-0.75-1.5-3-7.5-15-30A.&lt;BR&gt;&lt;BR&gt;Number of dials: 100 one hundred and fifty&lt;BR&gt;&lt;BR&gt;Features and uses: Wire structure instrument, with a scale length of 110mm and a weight not exceeding 2kg. It can be used as a standard meter and has been rated as a provincial excellent product. The outer dimensions are 210 * 152 * 190mm. Can be replaced by C19, C21, C33, C29, C31, C36, C38, C42, C46, C59, C63, C80 model instruments&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]0.5 type DC micro milliampere meter (0.5 level multi limit) </title>
           <link>http://www.91way.com/info_en/11151.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:31</pubDate>
           <comments></comments>
           <description>0.5 level multi limit C65uA&lt;BR&gt;&lt;BR&gt;Main indicators:&lt;BR&gt;&lt;BR&gt;Limit uA: 0-10-20-50 米 A, 0-50-100-200 米 A, 0-200-500-1000 米 A,&lt;BR&gt;0-50-100-200-500-1000米A.&lt;BR&gt;0-10-20-50-100-200-500-1000米A.&lt;BR&gt;&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: C65mA&lt;BR&gt;&lt;BR&gt;Main indicators:&lt;BR&gt;&lt;BR&gt;quantifier mAㄩ0-0.5-1-2mA. 0-0.5-1-2-5-10mA. 0-5-10-20mA. 0-50-100-200mA. 0-10-20-50-100-200mA. 0-100-200-500-1000mA&lt;BR&gt;&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Model: C65A&lt;BR&gt;&lt;BR&gt;Main indicators:&lt;BR&gt;&lt;BR&gt;Limit A: 0-1-2-5-10-20A. 0-1.5-3-7.5-15-30A&lt;BR&gt;0-0.0005(45mv)-0.001-0.002-0.005-0.01-0.02-0.05-0.1-0.2-0.5-1-2-5-10-20A.&lt;BR&gt;0-0.00075(45mv)-0.0015-0.003-0.0075-0.015-0.03-0.075-0.15-0.3-0.75-1.5-3-7.5-15-30A.&lt;BR&gt;&lt;BR&gt;Number of dials: 100 one hundred and fifty&lt;BR&gt;&lt;BR&gt;Features and uses: Wire structure instrument, with a scale length of 110mm and a weight not exceeding 2kg. It can be used as a standard meter and has been rated as a provincial excellent product. The outer dimensions are 210 * 152 * 190mm. Can be replaced by C19, C21, C33, C29, C31, C36, C38, C42, C46, C59, C63, C80 model instruments&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]C64-A DC Ampere Meter </title>
           <link>http://www.91way.com/info_en/11148.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:23</pubDate>
           <comments></comments>
           <description>Model: C64-A&lt;BR&gt;Product: DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Quantity limit: 0-45-75mV-0.75-1.5-3-7.5-15-30-75mA-0.15-0.3-0.75-1.5-3-7.5-15-30A&lt;BR&gt;Number of dials: 150&lt;BR&gt;Level 0.2&lt;BR&gt;&lt;BR&gt;Overall dimensions:&lt;BR&gt;290x200x120mm&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;The length of the gauge for the wire structure instrument is 160mm, with a weight of ≒ 4kg. The instrument has multiple measurement limits, high sensitivity, and a voltage limit that consumes 1mA of current, which can replace C41&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D8-mA AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/11140.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:14</pubDate>
           <comments></comments>
           <description>Model: D8 mA&lt;BR&gt;Product: AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Quantity limit: 0-5-10mA 0-25-50mA 0-50-100mA&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.5&lt;BR&gt;&lt;BR&gt;Dimensions: 232x289x172mm&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;The cursor of the tensioning mechanism indicates a low consumption ruler with a length of 150mm, a weight of ≒ 8kg, and a working frequency of 50-1500HZ for wattmeters and 50HZ for milliammeters and voltmeters. It can measure low-power electrical parameters and can replace the D39 type&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D4-A Type 0.1 Class AC/DC Ampere Meter for Electric Power Systems </title>
           <link>http://www.91way.com/info_en/11133.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:47:06</pubDate>
           <comments></comments>
           <description>Model: D4-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Limits: 0-0.5-1A, 0-2.5-5A, 0-5-10A&lt;BR&gt;Working frequency: 45-65-1000Hz&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;&lt;BR&gt;Adopting a tension spring structure, the cursor length is 550mm, and the weight of the cursor scale is 12kg&lt;BR&gt;&lt;BR&gt;Overall dimensions:&lt;BR&gt;&lt;BR&gt;The cursor indicator 365x350x165 can replace the T30/D50 instrument panel&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D61-A AC/DC Ampere Meter </title>
           <link>http://www.91way.com/info_en/11130.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:57</pubDate>
           <comments></comments>
           <description>Model: D61-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Limits: 0-0.5-1A, 0-2.5-5A, 0-5-10A&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.2&lt;BR&gt;&lt;BR&gt;Overall dimensions:&lt;BR&gt;275x200x120mm can replace T24/D40 instruments&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;&lt;BR&gt;The length of the wire structure ruler is 150mm, and the weight is ≒ 3.5kg. The working frequency is 45-65.90-110. 180-1000HZ, Suitable for precision measurement in standard tables and laboratories, the original D62 instrument&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D61-mA AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/11129.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:49</pubDate>
           <comments></comments>
           <description>Model: D61-mA&lt;BR&gt;Product: AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Limit: 0-25-50mA 0-100-200mA&lt;BR&gt;Working frequency: 45-65, 90-110, 180-1000Hz,&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.2&lt;BR&gt;&lt;BR&gt;Dimensions: 275x200x120mm can replace T24/D40 instruments&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;&lt;BR&gt;Wire structure ruler length 150mm, weight ≒ 3.5kg&lt;BR&gt;Suitable for precision measurement in standard tables and laboratories, the original D62 instrument&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D76-A type electric series AC/DC ammeter </title>
           <link>http://www.91way.com/info_en/11125.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:40</pubDate>
           <comments></comments>
           <description>Model: D76-A&lt;BR&gt;Product: AC/DC Ampere Meter&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&lt;BR&gt;Limits: 0-0.5-1A, 0-2.5-5A, 0-5-10A&lt;BR&gt;Number of dials: 100&lt;BR&gt;Level 0.2&lt;BR&gt;&lt;BR&gt;Dimensions: 360x350x136mm can replace D40 and T24 instruments&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D76-mA electric series AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/11124.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:32</pubDate>
           <comments></comments>
           <description>Model: D76 mA&lt;BR&gt;Product: AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;Level 0.2&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;Limits: 0-25-50mA, 0-50-100mA, 0-250-500mA&lt;BR&gt;Working frequency: 45-65Hz&lt;BR&gt;Number of dials: 100&lt;BR&gt;&lt;BR&gt;Dimensions: 360x350x136mm can replace D40 and T24 instruments&lt;BR&gt;&lt;BR&gt;Characteristics and Applications:&lt;BR&gt;&lt;BR&gt;The shaft tip support can be used as a standard gauge instead of the original D2W instrument with a ruler length of 280mm and a vernier scale weight ≒ 11kg.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]PZ158B DC voltage/current meter </title>
           <link>http://www.91way.com/info_en/9461.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:23</pubDate>
           <comments></comments>
           <description>I. Overview&lt;BR&gt;&lt;BR&gt;The PZ158B DC voltage/current meter has a 51/2 bit display and can measure DC voltage of 1 米 V-1000V and DC current of 1nA-200mA. It has an automatic range and can perform automatic zero calibration and panel calibration. It has an RS232C interface and can be easily connected to computer systems. The display uses a seven bit VFD fluorescent digital tube or LED (PZ158B/1) display.&lt;BR&gt;&lt;BR&gt;2﹜ Main technical indicators&lt;BR&gt;&lt;BR&gt;(1) Measurement speed: 1.2 times/second&lt;BR&gt;(2) Basic error: 0.2V, 2V Range: &#177; (0.005% RD+0.0015% FS)&lt;BR&gt;Range of 20V, 200V, 1000V: &#177; (0.006% RD+0.002% FS)&lt;BR&gt;Range of 0.2, 2, 20, 200mA: &#177; (0.02% RD+0.002% FS)&lt;BR&gt;(3) Maximum display modulus: 220000&lt;BR&gt;(4) Dimensions: 88 &#215; 235 &#215; 360mm&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]HB436A/HB439A Intelligent three-phase ammeter </title>
           <link>http://www.91way.com/info_en/9035.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:15</pubDate>
           <comments></comments>
           <description>HB436A/HB439A intelligent three-phase ammeter&lt;BR&gt;&lt;BR&gt;1﹜ Characteristics&lt;BR&gt;&lt;BR&gt;HB436A/HB439A intelligent three-phase ammeter simultaneously inputs three-phase current, and displays three-phase current values in three rows simultaneously. According to the equipped current transformer, the range display can be set arbitrarily, and the upper and lower limits of the two relays are alarmed. The alarm range can be set arbitrarily&lt;BR&gt;&lt;BR&gt;2﹜ Technical parameters&lt;BR&gt;1. Working power supply: AC/DC85-260V (other voltages can be customized)&lt;BR&gt;2. Input range: AC0-5A&lt;BR&gt;3. Extended range: 0-9999KA (with current transformer)&lt;BR&gt;4. Response frequency: 50Hz or 60Hz&lt;BR&gt;5. Measurement method: True RMS measurement&lt;BR&gt;6. Maximum overload: 10A for one minute&lt;BR&gt;7. Display range: -1999 to 9999&lt;BR&gt;8. Display resolution: 0.001A&lt;BR&gt;9. Basic error: 0.5% &#177; 2 words&lt;BR&gt;10. Input impedance: 0.02 次&lt;BR&gt;11. Contact capacity: AC220V/3A&lt;BR&gt;12. Display digital tube: 436:3 rows of red 0.56-inch LED&lt;BR&gt;439:3 rows of red 0.8-inch LEDs&lt;BR&gt;13. Working environment: 0-50 ⊥; ≒85ㄔRH&lt;BR&gt;&lt;BR&gt;3﹜ Model Description&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009119225840383.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=0 hspace=0 alt=&quot;Model Description of HB436A/HB439A Intelligent Three phase Ammeter&quot; src=&quot;/upload2009/200911/2009119225840383.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;HB436A/HB439A intelligent three-phase ammeter&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]HB40X series intelligent AC/DC ammeter </title>
           <link>http://www.91way.com/info_en/9030.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:46:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;HB40X series intelligent AC/DC ammeter&lt;BR&gt;&lt;BR&gt;1﹜ Characteristics&lt;BR&gt;Compatible input of AC current and DC current signals&lt;BR&gt;AC: 5A﹜1A﹜100mA﹜XXXXA/5A&lt;BR&gt;DC: 5A﹜1A﹜100mA﹜XXXXA/75mV&lt;BR&gt;Zero value, full value, and decimal point can be freely set&lt;BR&gt;Multi level digital filtering selection effectively eliminates critical skip words&lt;BR&gt;Two relay alarm outputs, with alarm values set arbitrarily&lt;BR&gt;Simulate current and voltage transmission output, with adjustable transmission range&lt;BR&gt;&lt;BR&gt;2﹜ Technical parameters&lt;BR&gt;1. Working power supply: AC/DC85-260V (other voltages can be customized)&lt;BR&gt;2. Input signal: AC: 5A, 1A, 100mA, XXXXA/75mV&lt;BR&gt;DC: 5A﹜1A﹜100mA﹜XXXXA/5A&lt;BR&gt;3. DC current display range: -1999 to 9999&lt;BR&gt;4. AC current display range: 0-9999&lt;BR&gt;5. DC current measurement accuracy: &#177; (0.8%+3 words)&lt;BR&gt;6. AC current measurement accuracy: &#177; (1.0%+5 words)&lt;BR&gt;7. Over limit display: &quot;EEEE&quot; or &quot;- EEE&quot;&lt;BR&gt;8. Overload range: 10A for 1 minute&lt;BR&gt;9. Transmission output signal: 4-20mA, 0-20mA&lt;BR&gt;10. Transmission output accuracy: &#177; 1% FS&lt;BR&gt;11. Transmission load: not less than 500 次&lt;BR&gt;12. Relay output: 2-channel relay normally open and normally closed output&lt;BR&gt;13. Contact capacity: AC220V/3A&lt;BR&gt;14. Working environment: 0-50 ⊥; ≒85ㄔRH&lt;BR&gt;&lt;BR&gt;3﹜ Model Description&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/2009119224433444.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Model Description of HB40X Series Intelligent AC/DC Ammeter&quot; src=&quot;/upload2009/200911/2009119224433444.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;HB40X series intelligent AC/DC ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]HB4740/HB5740 Intelligent AC/DC ammeter </title>
           <link>http://www.91way.com/info_en/9028.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;HB4740/HB5740 Intelligent AC/DC Ammeter&lt;BR&gt;&lt;BR&gt;1﹜ Characteristics&lt;BR&gt;Compatible input of AC current and DC current signals&lt;BR&gt;AC: 5A﹜1A﹜100mA﹜XXXXA/5A&lt;BR&gt;DC: 5A﹜1A﹜100mA﹜XXXXA/75mV&lt;BR&gt;Zero value, full value, and decimal point can be freely set&lt;BR&gt;&lt;BR&gt;2﹜ Technical parameters&lt;BR&gt;1. Working power supply: AC/DC85-260V (other voltages can be customized)&lt;BR&gt;2. Measurement method: True RMS measurement&lt;BR&gt;3. Over limit display: &quot;EEEE&quot; or &quot;- EEE&quot;&lt;BR&gt;4. Contact capacity: Two relays with normally open and normally closed outputs of AC250/3A&lt;BR&gt;5. Transmission output: 4-20mA, 0-20mA&lt;BR&gt;6. Transmission load: not less than 500 次&lt;BR&gt;7. DC current display range: -1999 to 9999&lt;BR&gt;8. AC current display range: 0-9999&lt;BR&gt;9. DC current measurement accuracy: &#177; (0.8%+3 words)&lt;BR&gt;10. AC current measurement accuracy: &#177; (1.0%+5 words)&lt;BR&gt;11. Working environment: 0-50 ⊥; ≒85ㄔRH&lt;BR&gt;&lt;BR&gt;3﹜ Model Description&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911922380145.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 195px&quot; border=0 hspace=0 alt=&quot;Model Description of HB4740/HB5740 Intelligent AC/DC Ammeter&quot; src=&quot;/upload2009/200911/200911922380145.jpg&quot; width=680 height=195&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;HB4740/HB5740 Intelligent AC/DC Ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]CD194I series intelligent three-phase ammeter </title>
           <link>http://www.91way.com/info_en/8242.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:48</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;Panel size: 72X72mm&lt;/DIV&gt;
&lt;DIV align=left&gt;Installation hole size: 67X67mm&lt;/DIV&gt;
&lt;DIV align=left&gt;Display: 3 rows of LED display, adjustable brightness&lt;/DIV&gt;
&lt;DIV align=left&gt;Function description: Measure and display three-phase current;
&lt;DIV&gt;Optional alarm output, transmission output, RS485 communication;&lt;/DIV&gt;
&lt;DIV&gt;Support key programming to set various parameters;&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;technical indicators&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;performance category&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;accuracy class&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Level 0.2, Level 0.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Display&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Three rows of 4-digit LED display with adjustable brightness&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Nominal input&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Voltage: AC 100V 220V 380V; Current: AC 1A, 5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;input impedance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Voltage&amp;gt;1M 次, current&amp;lt;20m 次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;50/60Hz&#177;10%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;overload capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Duration: 1.2 times instantaneous: voltage 2 times (1 second), current 10 times (5 seconds)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Whole meter power consumption&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;&amp;lt;2.5VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;working power supply&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;AC110/220/380v﹜AC/DC 80V~260V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;contact method&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;RS-485 interface, MODBUS-RTU protocol&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;alarm output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;2-channel relay output&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;transmitter output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;4~20mA //0~20mA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;working conditions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Environmental temperature -10~55 ⊥, relative humidity ≒ 93%, non corrosive gas environment, altitude ≒ 2500m&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;insulation resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;≡100M次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911203918550.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 638px; HEIGHT: 713px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CD194I series intelligent three-phase ammeter&quot; src=&quot;/upload2009/200911/200911203918550.gif&quot; width=638 height=713&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CD194I series intelligent three-phase ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]CD194I series intelligent single-phase ammeter </title>
           <link>http://www.91way.com/info_en/8236.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:40</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;CD194I-AK1 intelligent single-phase ammeter&lt;BR&gt;&lt;BR&gt;Panel size: 72X72mm&lt;/DIV&gt;
&lt;DIV align=left&gt;Installation hole size: 67X67mm&lt;/DIV&gt;
&lt;DIV align=left&gt;Display: Single row LED display, adjustable brightness&lt;/DIV&gt;
&lt;DIV align=left&gt;Function description: Measure and display single-phase current;
&lt;DIV&gt;Optional alarm output, transmission output, RS485 communication;&lt;/DIV&gt;
&lt;DIV&gt;Support key programming to set various parameters;&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;technical indicators&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;performance category&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;accuracy class&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Level 0.2, Level 0.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Display&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;4-digit LED display with adjustable brightness&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Nominal input&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Voltage: AC 100V 220V 380V; Current: AC 1A, 5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;input impedance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Voltage&amp;gt;1M 次, current&amp;lt;20m 次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;operating frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;50/60Hz&#177;10%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;overload capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Duration: 1.2 times instantaneous: voltage 2 times (1 second), current 10 times (5 seconds)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;Whole meter power consumption&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;&amp;lt;1.5VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;working power supply&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;AC110/220/380v﹜AC/DC 80V~260V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;contact method&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;RS-485 interface, MODBUS-RTU protocol&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;alarm output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;2-channel relay output&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;transmitter output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;4~20mA //0~20mA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;working conditions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;Environmental temperature -10~55 ⊥, relative humidity ≒ 93%, non corrosive gas environment, altitude ≒ 2500m&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=133&gt;
&lt;DIV align=center&gt;insulation resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=432&gt;
&lt;DIV align=center&gt;≡100M次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911203645591.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 638px; HEIGHT: 713px&quot; border=0 hspace=0 alt=&quot;Technical parameters of CD194I series intelligent single-phase ammeter&quot; src=&quot;/upload2009/200911/200911203645591.gif&quot; width=638 height=713&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CD194I series intelligent single-phase ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1602 AC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8089.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:31</pubDate>
           <comments></comments>
           <description>ZW1602 AC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC (15mA~15A)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 5 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC (85V-265V)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 300g&lt;BR&gt;&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1619 AC/DC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8088.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:22</pubDate>
           <comments></comments>
           <description>ZW1619 AC/DC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC/DC (5A), 75mV splitter&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 5 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC (85V-265V)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 300g&lt;BR&gt;&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW3431 three-phase AC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8087.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:13</pubDate>
           <comments></comments>
           <description>ZW3431 three-phase AC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC 3 &#215; I (5A)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 4 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 96 (H) &#215; 96 (W) &#215; 124 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 90 &#215; 90mm&lt;BR&gt;Instrument weight NetWeight: ＞ 600g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW5431 three-phase AC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8086.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:45:04</pubDate>
           <comments></comments>
           <description>ZW5431 three-phase AC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC 3 &#215; I (5A)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 4 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 80 (H) &#215; 160 (W) &#215; 130 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 150 &#215; 75mm&lt;BR&gt;Instrument weight NetWeight: ＞ 600g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1419 AC/DC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8085.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:52</pubDate>
           <comments></comments>
           <description>ZW1419 AC/DC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC/DC (5A), 75mV splitter&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 4 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 112 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 340g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW5402 AC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8084.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:43</pubDate>
           <comments></comments>
           <description>ZW5402 AC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC (15A)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 4 digits, 0.8 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 80 (H) &#215; 160 (W) &#215; 124 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 150 &#215; 75mm&lt;BR&gt;Instrument weight NetWeight: ＞ 600g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1402 AC 0.5 level ammeter </title>
           <link>http://www.91way.com/info_en/8083.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:35</pubDate>
           <comments></comments>
           <description>ZW1402 AC 0.5 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC (15A)&lt;BR&gt;Accuracy level: Level 0.5&lt;BR&gt;Display: 4 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 112 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 340g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1659 AC/DC 0.2 level ammeter </title>
           <link>http://www.91way.com/info_en/8082.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:26</pubDate>
           <comments></comments>
           <description>ZW1659 AC/DC 0.2 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC (0.015-15A)&lt;BR&gt;Accuracy level: 0.2&lt;BR&gt;Display: 5 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC (85V-265V)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 300g&lt;BR&gt;&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]ZW1652 AC 0.2 level ammeter </title>
           <link>http://www.91way.com/info_en/8081.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:17</pubDate>
           <comments></comments>
           <description>ZW1652 AC 0.2 level ammeter&lt;BR&gt;&lt;BR&gt;Measurement item: AC (0.015-15A)&lt;BR&gt;Accuracy level: 0.2&lt;BR&gt;Display: 5 digits, 0.5 &quot;LED&lt;BR&gt;Power Supply: AC (85V-265V)&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91mm&lt;BR&gt;Instrument weight NetWeight: ＞ 300g&lt;BR&gt;&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]D9-A/mA AC medium frequency milliampere meter </title>
           <link>http://www.91way.com/info_en/8034.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:09</pubDate>
           <comments></comments>
           <description>Specification and main technical parameters of electric AC/DC meters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=69&gt;Medium frequency milliampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=3&gt;D9mA-1&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-25mA&lt;/TD&gt;
&lt;TD rowSpan=14 colSpan=2&gt;265&#215;195&#215;135&lt;/TD&gt;
&lt;TD rowSpan=14 width=138 colSpan=2&gt;Suitable for measuring current and voltage in DC circuits or AC circuits at any frequency between 45-1500 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-50 mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100 mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=69&gt;Intermediate frequency ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=4&gt;D9A-1&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.25-0.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-0.5-1A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;D9-A/mA AC medium frequency milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]T30-A/mA AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/8027.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:44:00</pubDate>
           <comments></comments>
           <description>T30-A/mA AC/DC milliampere meter specifications and main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=56&gt;AC/DC ammeter level 0.1&lt;/TD&gt;
&lt;TD rowSpan=4 width=50&gt;T30-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-5-10A&lt;/TD&gt;
&lt;TD rowSpan=8 colSpan=2&gt;320&#215;240&#215;140&lt;/TD&gt;
&lt;TD rowSpan=8 width=170 colSpan=2&gt;Electromagnetic wire supported dual spot indicator portable electric meter, used for precise measurement of AC/DC voltage and current in laboratories or as a standard meter in metrology rooms.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-3-6A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-0.75-1.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=56&gt;AC/DC milliampere meter level 0.1&lt;/TD&gt;
&lt;TD rowSpan=2 width=50&gt;T30-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-250-500mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200mA&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;T30-A/mA AC/DC milliampere meter&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]T24-A AC Ampere Meter </title>
           <link>http://www.91way.com/info_en/8026.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:52</pubDate>
           <comments></comments>
           <description>Specification and main technical parameters of T24-A AC ammeter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=56&gt;AC Ampere Meter Level 0.2&lt;/TD&gt;
&lt;TD rowSpan=2 width=50&gt;T24-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.075-0.15-0.3-0.75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;-1.5-3-7.5-15- 30 -60A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;320&#215;235&#215;145&lt;BR&gt;&lt;BR&gt;The T24-A AC ammeter is used for precision measurement of AC voltage, current, or as a standard meter in the laboratory.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]T24-A/mA AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/8025.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:43</pubDate>
           <comments></comments>
           <description>Specification and main technical parameters of electromagnetic AC/DC meters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=56&gt;AC/DC volt ampere meter level 0.2&lt;/TD&gt;
&lt;TD rowSpan=2 width=50&gt;T24-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-15-30-60mA&lt;/TD&gt;
&lt;TD rowSpan=8 colSpan=2&gt;320&#215;235&#215;145&lt;/TD&gt;
&lt;TD rowSpan=8 width=170 colSpan=2&gt;Electromagnetic wire supported portable electric meter, used for precise measurement of AC/DC voltage and current in laboratories or as a standard meter in measurement rooms.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-75-150-300mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=56&gt;AC/DC Ampere Meter Class 0.2&lt;/TD&gt;
&lt;TD rowSpan=3 width=50&gt;T24-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.5-1A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;T24-A/mA AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]T19-A AC Ampere Meter </title>
           <link>http://www.91way.com/info_en/8024.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:35</pubDate>
           <comments></comments>
           <description>Specification and main technical parameters of electromagnetic AC/DC meters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=56&gt;AC ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=2 width=50&gt;T19-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-5-10-50-100A&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;220&#215;170&#215;115&lt;/TD&gt;
&lt;TD rowSpan=2 width=170 colSpan=2&gt;Used for measuring current in AC 50Hz circuits.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-10-25-50-100A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;T19-A type AC ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]T19-A/mA AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/8023.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:26</pubDate>
           <comments></comments>
           <description>Specification and main technical parameters of electromagnetic AC/DC meters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=56&gt;AC/DC milliampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=6&gt;T19-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-10-20mA&lt;/TD&gt;
&lt;TD rowSpan=19 colSpan=2&gt;220&#215;170&#215;100&lt;/TD&gt;
&lt;TD rowSpan=19 width=170 colSpan=2&gt;Used for measuring voltage or current in DC circuits and AC 50Hz circuits.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-25-50mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-50-100mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-150-300mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-250-500mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=56&gt;AC/DC ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=4&gt;T19-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.5-1A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-1-2A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;The T19-A/mA AC/DC milliampere meter is used for measuring voltage or current in DC circuits and AC 50Hz circuits.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C67-A/mA/uA type DC micro milliampere meter </title>
           <link>http://www.91way.com/info_en/8006.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:17</pubDate>
           <comments></comments>
           <description>Specification and Main Technical Parameters of Magnetoelectric DC Meter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=8&gt;DC panel meter 0.5 level&lt;/TD&gt;
&lt;TD&gt;C67-米A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-50米A; 0-100米A; 00200米A; 0-500米A&lt;/TD&gt;
&lt;TD rowSpan=8 colSpan=2&gt;164&#215;143&#215;95&lt;/TD&gt;
&lt;TD rowSpan=8 colSpan=2&gt;Used for displaying current, voltage, and various parameters in DC circuits on analytical and electronic instruments&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;C67-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1mA; 0-2mA; 0-5mA; 0-10mA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-20mA; 0-50mA; 0-100mA; 0-500mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;C67-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1A; 0-5A; 0-10A; 0-20A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C67-A/mA/uA type DC micro milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C50-A/mA/uA type DC micro milliampere meter </title>
           <link>http://www.91way.com/info_en/8005.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:09</pubDate>
           <comments></comments>
           <description>Specification and Main Technical Parameters of Magnetoelectric DC Meter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;DC microampere meter&lt;/TD&gt;
&lt;TD&gt;C50-米A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-50-100-200-500-1000米A&lt;/TD&gt;
&lt;TD rowSpan=7 colSpan=2&gt;325&#215;240&#215;140&lt;/TD&gt;
&lt;TD rowSpan=7 colSpan=2&gt;A portable DC meter with dual light point indication supported by a wire Used as a standard meter in factories, research departments' metrology rooms, and for precision electrical measurements in laboratories&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC milliampere meter&lt;/TD&gt;
&lt;TD&gt;C50-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15-30-75-150-300-750mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC ammeter&lt;/TD&gt;
&lt;TD&gt;C50-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C50-A/mA/uA type DC micro milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C41-A/mA/uA type DC micro milliampere meter </title>
           <link>http://www.91way.com/info_en/8004.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:43:00</pubDate>
           <comments></comments>
           <description>Specification and Main Technical Parameters of Magnetoelectric DC Meter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC microampere meter level 0.2&lt;/TD&gt;
&lt;TD rowSpan=3&gt;C41-米A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-50米A&lt;/TD&gt;
&lt;TD rowSpan=18 colSpan=2&gt;320&#215;235&#215;120&lt;/TD&gt;
&lt;TD rowSpan=18 colSpan=2&gt;The instrument adopts a wire support and multiple reflection light point indication structure, so it has extremely high sensitivity and consumes very little power. It is particularly suitable for weak current measurement and transistor static parameter testing, as well as for measuring the output millivolts of thermocouples in vacuum furnaces (or hydrogen furnaces)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-75米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200-500-1000米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5&gt;DC milliampere meter level 0.2&lt;/TD&gt;
&lt;TD rowSpan=5&gt;C41-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-3-7.5-15-30mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10-20-50mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200-500-1000mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15-30-75-150-300-750-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;1500mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;DC Ampere Meter Class 0.2&lt;/TD&gt;
&lt;TD rowSpan=2&gt;C41-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-2-5-10-20A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15-30A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C41-A/mA/uA type DC micro milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C38-uA Type 0.5 Class DC microampere meter </title>
           <link>http://www.91way.com/info_en/8003.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:52</pubDate>
           <comments></comments>
           <description>Specification and Main Technical Parameters of Magnetoelectric DC Meter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC microampere meter level 0.5&lt;/TD&gt;
&lt;TD&gt;C38-米A/1&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1-2-5-10-20-50-100-200-500-1000米A&lt;/TD&gt;
&lt;TD rowSpan=10 colSpan=2&gt;220&#215;170&#215;118&lt;/TD&gt;
&lt;TD rowSpan=10 colSpan=2&gt;By adopting a wire support structure, the sensitivity and service life of the instrument have been improved Can be used for measuring current and voltage in DC circuits and as a standard meter on production lines&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;C38-米A/2&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15-30-75-150-300-750-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;1000 米A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C38 uA type 0.5 level DC microampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C30-A Type DC Ampere (Milliampere) Meter </title>
           <link>http://www.91way.com/info_en/8002.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:43</pubDate>
           <comments></comments>
           <description>Specifications and Main Technical Parameters of Magnetoelectric DC Meter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC milliampere meter level 1.0&lt;/TD&gt;
&lt;TD rowSpan=3&gt;C30-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5-7.5-15-30mA&lt;/TD&gt;
&lt;TD rowSpan=21 colSpan=2&gt;135&#215;105&#215;57&lt;/TD&gt;
&lt;TD rowSpan=21 colSpan=2&gt;Instruments with splash proof protection performance and a certain degree of shock resistance&lt;BR&gt;Suitable for outdoor use for convenience A certain level of shock resistance Suitable for outdoor and onboard use&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-3-15-75-150mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-50-100-500-1000mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC Ampere Meter Class 1.0&lt;/TD&gt;
&lt;TD rowSpan=3&gt;C30-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.3-0.75-1.5-3A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5-10-20A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-3-7.5-15-30A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C30-A type DC ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C21-A type DC ammeter (milliampere, microampere) </title>
           <link>http://www.91way.com/info_en/8001.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:35</pubDate>
           <comments></comments>
           <description>C21-A type DC ampere meter (milliampere, microampere)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC microampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=3&gt;C21/1-米A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-10; 0-25; 0-50; 0-100; 0-150; 0-200;&lt;/TD&gt;
&lt;TD rowSpan=9 colSpan=2&gt;214&#215;194&#215;95&lt;/TD&gt;
&lt;TD rowSpan=18 colSpan=2&gt;Adopting a wire support structure, it can be used for measuring current and voltage in DC circuits and as a standard meter on production lines.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-300; 0-500; 0-1000; &#177;5; &#177;25; &#177;50; &#177;75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;&#177;100; &#177;150; &#177;250; &#177;500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4&gt;DC Hao'an meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=4&gt;C21/1-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5˙ 0-3˙ 0-5; 0-7.5; 0-10; 0-1.5-3;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5; 0-5-10; 0-10-20; 0-15-30;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-25-50; 0-50-100; 0-75-150;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200; 0-150-300; 0-250-500;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;DC ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=2&gt;C21/1-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.5-1; 0-1.5-3; 0-2.5-5; 0-5-10;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-10-20; 0-15-30&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;C21-A type DC ammeter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]SB2238 type DC digital voltmeter and ammeter </title>
           <link>http://www.91way.com/info_en/7729.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:26</pubDate>
           <comments></comments>
           <description>The SB2238 DC digital voltmeter and ammeter is a high-precision electronic measuring instrument with microcomputer technology, featuring a five and a half digit reading, 1uV voltage resolution, and 0.1uA current resolution. This meter adopts advanced microcomputer and analog-to-digital conversion technology, which can perform automatic zero calibration and digital analog filtering. The zero position of the meter is stable, the reading is linear, and the anti-interference ability is strong. The display adopts seven bit LED with RS-232C standard serial communication interface, which can communicate with computers. Its excellent performance plays a great role in scientific research, industry, national defense and other fields.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;1. Measurement range:&lt;BR&gt;Voltage: 1uV~220.000V&lt;BR&gt;Current: 0.1uA~100mA&lt;BR&gt;2. Power supply: 220V &#177; 10%, 50Hz &#177; 1%&lt;BR&gt;3. Dimensions: 280 &#215; 210 &#215; 100 (mm)&lt;BR&gt;4. Quality: Approximately 3kg&lt;BR&gt;&lt;BR&gt;Main technical parameters of each range:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;range&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;basic error&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;200mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1uV~220.000mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1uV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.005% RD+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;2V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10uV~2.20000V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10uV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.003% RD+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;20V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100uV~22.0000V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100uV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.006% RD+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;200V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1mV~220.000V&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1mV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.006% RD+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;20mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.1uA~22.0000mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.1uA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.02% RD+3 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;100mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1uA~100.000mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1uA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&#177; (0.03% RD+3 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]UJ51 type low potential DC potentiometer </title>
           <link>http://www.91way.com/info_en/7728.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:17</pubDate>
           <comments></comments>
           <description>UJ51 type low potential DC potentiometer&lt;BR&gt;&lt;BR&gt;Description&lt;BR&gt;The UJ51 low potential DC potentiometer is suitable for precision measurement of electromotive force, DC current, and voltage in laboratories and metrology departments, and can also be used as a standard thermocouple potential calibration.&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;&lt;BR&gt;1. Measurement range: 0.1 &amp;micro; V~0.111110V&lt;BR&gt;2. Accuracy: 0.01&lt;BR&gt;3. Resolution: 0.1&lt;BR&gt;4. Dimensions: 477 &#215; 257 &#215; 170 (mm)&lt;BR&gt;5. Quality: 7.5Kg&lt;BR&gt;&lt;BR&gt;Complete set: (user provided)&lt;BR&gt;&lt;BR&gt;1. AC15/2 type galvanometer or AC15/5 type galvanometer&lt;BR&gt;2. AC24 type spot amplification galvanometer&lt;BR&gt;3. YJ42 precision stabilized power supply&lt;BR&gt;4. BC9a standard battery&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC24 type DC photoelectric amplification galvanometer </title>
           <link>http://www.91way.com/info_en/7704.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:09</pubDate>
           <comments></comments>
           <description>AC24 type DC photoelectric amplification galvanometer&lt;BR&gt;&lt;BR&gt;Description&lt;BR&gt;The AC24 DC photoelectric amplification galvanometer is specifically designed to improve the sensitivity of AC15/2 or AZ19 galvanometers during high-precision measurements.&lt;BR&gt;&lt;BR&gt;Main technical performance:&lt;BR&gt;&lt;BR&gt;1. Input resistance&amp;lt;20 次&lt;BR&gt;2. Voltage division value:&amp;lt;7 &#215; 10-9 v/div&lt;BR&gt;3. Damping time:&amp;lt;6s&lt;BR&gt;4. Drift:&amp;lt;10div/10min&lt;BR&gt;5. Low frequency noise:&amp;lt;2div&lt;BR&gt;6. Dimensions: 330 &#215; 175 &#215; 155 (mm)&lt;BR&gt;7. Weight: 4.5kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC5A electronic zero pointer </title>
           <link>http://www.91way.com/info_en/7702.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:42:00</pubDate>
           <comments></comments>
           <description>The AC5A electronic zero pointer has a novel design and stable performance. It can be used to detect weak potential differences and can also be used as a matching zero pointer for 0.01 level bridge and potentiometer. This meter does not need to consider impedance matching, has extremely short damping time, high sensitivity and adjustability, and is very convenient to use, especially for experimental purposes for college students.&lt;BR&gt;&lt;BR&gt;Main technical performance of AC5A electronic zero pointer:&lt;BR&gt;&lt;BR&gt;1. Maximum sensitivity: Voltage constant ≒ 1 microvolt/grid or current constant ≒ 2 &#215; 10-9 amperes/grid, drift for 8 hours is less than 2 small grids;&lt;BR&gt;2. Power supply:~220V;&lt;BR&gt;3. Dimensions: 195 &#215; 210 &#215; 137 (mm);&lt;BR&gt;4. Quality: Approximately 2kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC5/1-4 pointer type DC galvanometer </title>
           <link>http://www.91way.com/info_en/7699.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:52</pubDate>
           <comments></comments>
           <description>Description&lt;BR&gt;The AC5/1-4 pointer type DC ammeter is suitable for general research units, schools, and electrical testing; Used for zero position indication of various DC bridges, potentiometers, and other instruments.&lt;BR&gt;&lt;BR&gt;Main technical performance:&lt;BR&gt;&lt;BR&gt;1. Main technical data:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009102816559582.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 477px; HEIGHT: 130px&quot; border=0 hspace=0 alt=&quot;Technical parameters of AC5/1-4 pointer DC ammeter&quot; src=&quot;/upload2009/200910/2009102816559582.jpg&quot; width=477 height=130&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;2. Dimensions: 160 &#215; 105 &#215; 150 (mm)&lt;BR&gt;3. Mass: Approximately 1.5kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC4/3 type impulse DC galvanometer </title>
           <link>http://www.91way.com/info_en/7698.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:43</pubDate>
           <comments></comments>
           <description>Description&lt;BR&gt;The AC4/3 type impulse DC galvanometer is used in balance measurement circuits as a zero position indicator or as an instrument for measuring current, voltage, electricity, and magnetic flux.&lt;BR&gt;&lt;BR&gt;Main technical performance:&lt;BR&gt;&lt;BR&gt;1. Internal resistance&amp;lt;100 次; External critical resistance&amp;lt;3000 次&lt;BR&gt;2. Current constant:&amp;lt;1.5 &#215; 10-9 A/mm&lt;BR&gt;3. Electricity constant:&amp;lt;15 &#215; 10-9 C/mm&lt;BR&gt;4. Free oscillation period:&amp;gt;18s&lt;BR&gt;5. Dimensions: 200 &#215; 162 &#215; 245 (mm)&lt;BR&gt;6. Mass: Approximately 3.5kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[ammeter]AC15/1-6 type compound beam DC galvanometer </title>
           <link>http://www.91way.com/info_en/7633.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Main technical data of AC15/1-6 type compound injection DC galvanometer:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009102891829561.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 705px&quot; border=0 hspace=0 alt=&quot;Appearance and technical parameters of AC15/1-6 type compound injection DC galvanometer&quot; src=&quot;/upload2009/200910/2009102891829561.jpg&quot; width=533 height=705&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;2. Zero position invariant level: 0.5 divisions&lt;BR&gt;3. Symmetry of indicator deflection: 5%&lt;BR&gt;4. Lighting voltage:~6.3 volts or~220 volts&lt;BR&gt;5. Scale: Divide a length of 130 millimeters into 130 divisions, with each division being 1 millimeter&lt;BR&gt;The scale is 60-0-60&lt;BR&gt;6. Dimensions: 270 &#215; 175 &#215; 155 (mm)&lt;BR&gt;7. Quality: 3.25kg&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]C31-A/mA/uA type DC micro milliampere meter </title>
           <link>http://www.91way.com/info_en/4433.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The C31 type DC electric meter is a portable electric meter with magnetic electric wire support pointer indication. The instrument has good anti vibration performance, high sensitivity and service life. The C31 instrument is a multi limit instrument, and the limit conversion uses plugs for easy use Can be used for precision electrical experiments in laboratories of factories, schools, or research departments, or as standard meters in metrology rooms.&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;C31-A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;7.5/15/30/75/150/300/&lt;/DIV&gt;
&lt;DIV&gt;750mA/1.5/3/7.5/15/30A&lt;/DIV&gt;
&lt;DIV&gt;2/5/10/20A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;U:27-45mV&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;U＞45mV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;one hundred and fifty&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; class=index-1 border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=5&gt;DC microampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=5&gt;C31-米A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-10米A&lt;/TD&gt;
&lt;TD rowSpan=19 colSpan=2&gt;220&#215;170&#215;100&lt;/TD&gt;
&lt;TD rowSpan=24 colSpan=2&gt;By adopting a wire support structure, the instrument has been improved Sensitivity and service life. Can be used for measuring current and voltage in DC circuits and as a standard meter on production lines&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-20米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-50米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200-500-1000米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-150-300-750-1500米A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;DC milliampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=3&gt;C31-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10-20-50mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-100-200-500-1000mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4&gt;DC ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=4&gt;C31-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-7.5-15-30-75-150-300-750mA-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;1.5-3-7.5-15-30A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2-5-10-20A;0-1-3-10-30A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-1.5-3-7.5-15-30A;0-25-50-100A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;C31-A/mA/uA type DC micro milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]D26-A/mA series AC/DC milliampere meter </title>
           <link>http://www.91way.com/info_en/4430.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:18</pubDate>
           <comments></comments>
           <description>&lt;DIV&gt;Instrument measurement range and consumption&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;DIV&gt;Instrument model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV&gt;measurement range&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV&gt;Power consumption (watts)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;DIV&gt;Effective resistance and inductance of current circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;DIV&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;DIV&gt;D26mA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV align=center&gt;150/300mA&lt;/DIV&gt;
&lt;DIV align=center&gt;250/500mA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV align=center&gt;3W&lt;/DIV&gt;
&lt;DIV align=center&gt;3.4/4W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;DIV align=center&gt;＞240/58mH130/31次&lt;/DIV&gt;
&lt;DIV align=center&gt;＞90/23mH55/16次&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;D26-A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV align=center&gt;0.5/1A&lt;/DIV&gt;
&lt;DIV align=center&gt;1/2A&lt;/DIV&gt;
&lt;DIV align=center&gt;2.5/5A&lt;/DIV&gt;
&lt;DIV align=center&gt;5/10A&lt;/DIV&gt;
&lt;DIV align=center&gt;10/20A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV align=center&gt;3.8/4.3W&lt;/DIV&gt;
&lt;DIV align=center&gt;3.5/4.8W&lt;/DIV&gt;
&lt;DIV align=center&gt;5.9/7.5W&lt;/DIV&gt;
&lt;DIV align=center&gt;7.5/14W&lt;/DIV&gt;
&lt;DIV align=center&gt;16/26W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;DIV align=center&gt;＞23/5.4mH14.5/4.25次&lt;/DIV&gt;
&lt;DIV align=center&gt;＞5/1.25mH3.5/1.2次&lt;/DIV&gt;
&lt;DIV align=center&gt;＞1/0.23mH0.78/0.3次&lt;/DIV&gt;
&lt;DIV align=center&gt;＞0.0023/0.06mH0.32/0.14次&lt;/DIV&gt;
&lt;DIV align=center&gt;＞0.06/0.018mH0.16/0.065次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; class=index-1 border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=69&gt;AC/DC milliampere meter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=2&gt;D26-mA&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-150-300 mA&lt;/TD&gt;
&lt;TD rowSpan=11 colSpan=2&gt;265&#215;195&#215;135&lt;/TD&gt;
&lt;TD rowSpan=11 width=138 colSpan=2&gt;Used for measuring current, voltage, and power in DC circuits and AC 50Hz circuits, or as a standard meter.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-250-500 mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=69&gt;AC/DC ammeter level 0.5&lt;/TD&gt;
&lt;TD rowSpan=5&gt;D26-A&lt;/TD&gt;
&lt;TD colSpan=4&gt;0-0.5-1A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-1-2A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-2.5-5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-5-10A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;0-10-20A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;D26-A/mA series AC/DC milliampere meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[ammeter]CP-T481 Square moving iron AC ammeter </title>
           <link>http://www.91way.com/info_en/3949.html</link>
           <author></author>
           <guid></guid>
           <category>ammeter</category>
           <pubDate>2026-6-16 15:41:09</pubDate>
           <comments></comments>
           <description>CP-T481 Square Moving Iron AC Ammeter&lt;BR&gt;&lt;BR&gt;The instrument can indicate the true effective value of AC current or voltage with a measurement frequency between 15-100Hz, regardless of the waveform of the system. Represents the symbol T.&lt;BR&gt;The performance complies with GB/T7676-1998 and IEC60051 standards, and the shell size complies with IEC60473 and GB/T1242 standards; The KLY square series (48 &#215; 48, 72 &#215; 72, 96 &#215; 96, 144 &#215; 144) also complies with German DIN43700 and DIN61010 standards, as well as the RoHS directive.&lt;BR&gt;Accuracy: Level 1.5&lt;BR&gt;&lt;BR&gt;Specification: 0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 60A 75A 100A&lt;BR&gt;10-10KA uses external current transformers with secondary currents of 5A and 1A.&lt;BR&gt;Note: 60A 75A 100A is directly connected to the instrument, with an accuracy level of 2.5. The accuracy level of CP-48:25-60A directly connected to the instrument is 2.5.&lt;BR&gt;Shell: The CP series shell is made of flame-retardant ABS plastic, and the base is made of PPO plastic; The KLY series casing and base are both made of flame-retardant PC plastic. Both can be used for a long time at temperatures of 70 ⊥ and 120 ⊥ respectively, and the shell will not deform.&lt;BR&gt;Removable panel: The panel can be replaced without disassembling the instrument panel, making it easy to use and effectively dustproof. As long as the secondary current of the transformer is the same, the panels can be interchanged (48 &#215; 48 meters require the same scale division to interchange panels). When replacing the panel, it will not cause any damage to the instrument, and the accuracy level remains unchanged&lt;BR&gt;&lt;BR&gt;</description>
       </item>
</channel>
</rss>

