<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Instrument accessories</title>
       <link>http://www.91way.com</link>
       <description>Instrument accessories</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:14:34</pubDate>
       <item>
           <title>[Instrument accessories]XJ2370 type high-voltage probe </title>
           <link>http://www.91way.com/info_en/26934.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:35</pubDate>
           <comments></comments>
           <description>XJ2370 High Voltage Probe&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=2 cellPadding=1 width=650 align=center heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Model number&lt;/TD&gt;
&lt;TD&gt;XJ23700 3kV high voltage probe&lt;/TD&gt;
&lt;TD&gt;XJ23702 type 30kV high voltage probe&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=9&gt;
&lt;P&gt;sex&lt;/P&gt;
&lt;P&gt;can&lt;/P&gt;
&lt;P&gt;point&lt;/P&gt;
&lt;P&gt;mark&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;rise time&lt;/TD&gt;
&lt;TD&gt;≒35ns&lt;/TD&gt;
&lt;TD&gt;≒17.5ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum allowable input voltage&lt;/TD&gt;
&lt;TD&gt;3kV&lt;/TD&gt;
&lt;TD&gt;30kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;input impedance&lt;/TD&gt;
&lt;TD&gt;100M次//3pF&lt;/TD&gt;
&lt;TD&gt;100M次//12pF&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;decay ratio&lt;/TD&gt;
&lt;TD&gt;100孟1&lt;/TD&gt;
&lt;TD&gt;1000孟1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Upward impulse&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cooperate with the oscilloscope, not exceeding the rated value of the corresponding oscilloscope&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;phase correction&lt;/TD&gt;
&lt;TD colSpan=2&gt;By using an oscilloscope, correct compensation can be obtained&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical insulation resistance&lt;/TD&gt;
&lt;TD&gt;≡100M次&lt;/TD&gt;
&lt;TD&gt;≡100M次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Interface terminal&lt;/TD&gt;
&lt;TD&gt;Q9&lt;/TD&gt;
&lt;TD&gt;Q9&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;cable length&lt;/TD&gt;
&lt;TD&gt;1.5m&lt;/TD&gt;
&lt;TD&gt;1.5m&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for XJ23200 oscilloscope </title>
           <link>http://www.91way.com/info_en/26933.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Probe for XJ23200 100MHz Oscilloscope&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Indicator&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;switch position&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;&#215;10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;&#215;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;bandwidth&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;DC-100MHz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;DC-6MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;rise time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;≒3.5nS&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;≒50nS&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;decay ratio&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10垃1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1垃1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;scope of compensation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;18pF-45pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10M次//16pF&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1M次//50pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Upward impulse&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Phase calibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Maximum allowable input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;400V(DC-ACp)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Electrical insulation resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;≡100M次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Output plug/interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;BNC(Q9)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;cable length&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;1.2m&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for EN_1 oscilloscope </title>
           <link>http://www.91way.com/info_en/26932.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:17</pubDate>
           <comments></comments>
           <description>Probe for XJ23202 60MHz Oscilloscope&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Indicator&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;switch position&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;&#215;10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;&#215;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;bandwidth&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;DC-60MHz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;DC-6MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;rise time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;≒5nS&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;≒50nS&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;decay ratio&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10垃1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1垃1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;scope of compensation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;22pF-45pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10M次//20pF&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1M次//50pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Upward impulse&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Phase calibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Maximum allowable input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;400V(DC-ACp)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Electrical insulation resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;≡100M次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Output plug/interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;BNC(Q9)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;cable length&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;1.2m&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for EN_1 oscilloscope </title>
           <link>http://www.91way.com/info_en/26931.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:09</pubDate>
           <comments></comments>
           <description>XJ23400A 20MHz oscilloscope probe
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;serial number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Indicator&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;switch position&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;&#215;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;&#215;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;bandwidth&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;DC-20MHz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;DC-6MHz&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;rise time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;≒17.5nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;≒50nS&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;decay ratio&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;10垃1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;1垃1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;scope of compensation&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;25pF-45pF&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;input impedance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;10M次//25pF&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;1M次//50pF&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Upward impulse&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Phase calibration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Maximum allowable input voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;400V(DC-ACp)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Electrical insulation resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;≡100M次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Output plug/interface&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;BNC(Q9)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;cable length&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;1.2m&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]YD-1 Four terminal testing fixture </title>
           <link>http://www.91way.com/info_en/26791.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:59</pubDate>
           <comments></comments>
           <description>YD-1 Four Terminal Test Fixture&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]CD series testing pliers </title>
           <link>http://www.91way.com/info_en/23349.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:51</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CD series test pliers use ABS with high pressure resistance and strength as the clamp frame, and high-quality copper material with a certain hardness. After stamping and special nickel plating treatment, the pliers are formed into jaws. The jaws are divided into upper and lower layers and insulated to separate current and voltage. The CD series testing pliers have movable jaws and surface contact, making them convenient, safe, strong, and have good contact performance. CD-1 type test pliers are suitable for contact resistance testing; CD-2 type test pliers are suitable for circuit resistance testing; CD-3 type test pliers are suitable for various high-voltage switch and other tests.&lt;BR&gt;&lt;BR&gt;CD series test pliers with several different specifications and parameters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201304/20130414071710391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 545px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;CD series test pliers with different shapes&quot; src=&quot;/upload2013/201304/20130414071710391.jpg&quot; width=545 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201304/20130414071717313.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 529px; HEIGHT: 364px&quot; border=0 hspace=0 alt=&quot;CD series test pliers with external dimensions&quot; src=&quot;/upload2013/201304/20130414071717313.jpg&quot; width=529 height=364&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CD series testing pliers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]HNO3 Stainless steel pipe </title>
           <link>http://www.91way.com/info_en/20864.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:42</pubDate>
           <comments></comments>
           <description>HNO3 stainless steel pipe&lt;BR&gt;&lt;BR&gt;All stainless steel pipes are passivated with HNO3 and cleaned with methanol ultrasonic cleaning to ensure chromatographic use&lt;BR&gt;Smooth inner surface ensures optimal gas-liquid flow&lt;BR&gt;The annealed outer surface is bright and free of burrs, which is conducive to joint connection&lt;BR&gt;Suggest using a 0.020 &quot;or 0.030&quot; ID tube to transport the mobile phase from the pump to the injection valve&lt;BR&gt;It is recommended to use a 0.010 &quot;ID tube from the injection valve to the chromatographic column and from the chromatographic column to the detector, and keep these two distances as short as possible. This can reduce the out of column effect&lt;BR&gt;Provide various lengths of pre cut stainless steel pipes&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;Part NO.&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;outer diameter&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;inner diameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;625-04&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.005&quot;ㄗ0.1mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;625-05&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.007&quot;ㄗ0.2mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.01&quot;ㄗ0.25mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.02&quot;ㄗ0.5mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.03&quot;ㄗ0.75mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.04&quot;ㄗ1.0mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HNO3 stainless steel pipe&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Column-Guard protective column </title>
           <link>http://www.91way.com/info_en/20863.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:34</pubDate>
           <comments></comments>
           <description>Column Guard Protection Column&lt;BR&gt;&lt;BR&gt;In HPLC systems, it cannot be guaranteed that the injected samples can be completely eluted, especially for traditional Chinese medicine and blood samples. Although the injection volume is small, there will always be some residue in the column head after each injection, which will cause column head failure over time. This new type of protective column component combines the strength of stainless steel with the convenience and efficiency of PEEK pre filled column cores. Without the need for tools, place a small section of the protective column with the same packing as the column between the injection valve and the chromatographic column, which will extend the lifespan of the chromatographic column and ensure reproducibility of results.&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=90&gt;Part No&lt;/TD&gt;
&lt;TD width=360&gt;Desc.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and twenty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including C18/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and thirty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including C8/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and forty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core NH)&lt;SUB&gt;two&lt;/SUB&gt;/3 of them)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and fifty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core Sil/3 pieces)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;six hundred thousand two hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;Protective column components (including Phen/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and ten&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core CN/3 pieces)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and twenty-one&lt;/TD&gt;
&lt;TD width=360&gt;Protective column cover&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and twelve thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), C-18&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and twenty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), C-8&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and thirty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), Silica&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and forty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), NH&lt;SUB&gt;two&lt;/SUB&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and fifty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), CN&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;six hundred and sixty-two thousand one hundred and eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;Core (10/bag), Phen&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;Column Guard Protection Column&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

