<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Variable Frequency Drive (VFD)</title>
       <link>http://www.91way.com</link>
       <description>Variable Frequency Drive (VFD)</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:15:10</pubDate>
       <item>
           <title>[Variable Frequency Drive (VFD)]CFJ1 series universal frequency converter </title>
           <link>http://www.91way.com/info_en/26213.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:04:36</pubDate>
           <comments></comments>
           <description>CFJ1 series universal frequency converter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Maximum applicable rated power of electric motor&lt;/P&gt;
&lt;P align=center&gt;P&lt;SUB&gt;MN&lt;/SUB&gt;/kW&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;Input rated current&lt;/P&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;Continuous output rated current&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aN&lt;/SUB&gt;/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;brake unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aM&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Input rated voltage&lt;/P&gt;
&lt;P align=center&gt;U&lt;SUB&gt;VN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;Input rated frequency f&lt;SUB&gt;LN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;Rated fundamental AC voltage U on the load side&lt;SUB&gt;aN1&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Output (working) frequency range&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;6%&quot;&gt;
&lt;P&gt;CFJ1-1.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;four point one&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;built-in&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;1.5I&lt;SUB&gt;aN&lt;/SUB&gt;/1min£» 2I&lt;SUB&gt;aN&lt;/SUB&gt;/2s&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-440V (-15%,+10%)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;8%&quot;&gt;
&lt;P align=center&gt;50Hz/60Hz£¨&#177;5£¥£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-440V&lt;/P&gt;
&lt;P align=center&gt;£¨-15£¥£¬+10£¥£©&lt;/P&gt;
&lt;P align=center&gt;(Corresponding to the rated input voltage)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;0Hz¡«400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;6%&quot;&gt;
&lt;P&gt;CFJ1-2.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;six point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;five point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;6%&quot;&gt;
&lt;P&gt;CFJ1-3.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;three point seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;nine point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;6%&quot;&gt;
&lt;P&gt;CFJ1-5.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;6%&quot;&gt;
&lt;P&gt;CFJ1-7.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: Input the rated current value as a reference, which varies with the impedance of the power supply side (including input reactors and wires).&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;CFJ1 series universal frequency converter&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]CF1-SH series vector control frequency converter </title>
           <link>http://www.91way.com/info_en/26212.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:04:27</pubDate>
           <comments></comments>
           <description>CF1-SH series vector control frequency converter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Model (S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Maximum applicable rated power of electric motor&lt;/P&gt;
&lt;P align=center&gt;P&lt;SUB&gt;MN&lt;/SUB&gt;/kW&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Input rated current&lt;/P&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;Continuous output rated current&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aN&lt;/SUB&gt;/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;brake unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;DC reactor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aM&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Input rated voltage&lt;/P&gt;
&lt;P align=center&gt;U&lt;SUB&gt;VN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;Input rated frequency f&lt;SUB&gt;LN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Rated fundamental AC voltage U on the load side&lt;SUB&gt;aN1&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Output (working) frequency range&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-2.2SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;six point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;five point six&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;built-in&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Optional parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;1.5I&lt;SUB&gt;aN&lt;/SUB&gt;/1min£» 2I&lt;SUB&gt;aN&lt;/SUB&gt;/2s&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-460V (-15%,+10%)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;50Hz/60Hz£¨&#177;5£¥£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-460V (-15%,+10%)&lt;/P&gt;
&lt;P align=center&gt;(Corresponding to the rated input voltage)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;0Hz¡«400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-3.7SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;three point seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;nine point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-5.5SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-7.5SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-11SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-15SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-18.5SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;eighteen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;forty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-22SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;forty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;external&lt;/P&gt;
&lt;P align=center&gt;(Optional parts)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-30SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-37SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;thirty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;seventy-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;seventy-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-45SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-55SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-75SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and fifty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Standard configuration (external)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-90SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;one hundred and seventy-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-110SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;two hundred and fourteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-132SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;one hundred and thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and forty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;two hundred and fifty-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;CF1-160SH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and ninety-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;three hundred and four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: Input the rated current value as a reference, which varies with the impedance of the power supply side (including input reactors and wires).&lt;/P&gt;
&lt;P align=center&gt;CF1-SH series vector control frequency converter&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]CF1-NH series universal frequency converter </title>
           <link>http://www.91way.com/info_en/26211.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:04:18</pubDate>
           <comments></comments>
           <description>The CF1 series universal frequency converter is designed with a high-performance digital signal processor as the control core and a new generation of low loss, high reliability power module as the power circuit core, using advanced control algorithms. This series of frequency converters has comprehensive control functions and protection features, a friendly human-machine interface, rich programmable input/output terminals, expandable modular PG, communication, and programmable input/output, meeting various needs of users in different occasions. The entire series is divided into CF1-N V/f control type and CF1-S high-performance vector control type.&lt;BR&gt;The CF1-N series frequency converter is most suitable for the following applications: fans, pumps, general processing machinery, and transmission equipment.&lt;BR&gt;&lt;BR&gt;GB/T 12668.2-2002 Speed Control Electrical Transmission Systems Part 2: General Requirements for Rated Values of Low Voltage AC Variable Frequency Electrical Transmission Systems&lt;BR&gt;GB 12668.3-2003 Speed Control Electrical Transmission Systems Part 3: Electromagnetic Compatibility Standards and Specific Test Methods for Products&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;Technical parameter table of CF1 NH (V/f) type&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;Model (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;Maximum applicable rated power of electric motor&lt;/P&gt;
&lt;P align=center&gt;P&lt;SUB&gt;MN&lt;/SUB&gt;/kW&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Input rated current&lt;/P&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;Continuous output rated current&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aN&lt;/SUB&gt;/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;brake unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;DC reactor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;
&lt;P align=center&gt;I&lt;SUB&gt;aM&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Input rated voltage&lt;/P&gt;
&lt;P align=center&gt;U&lt;SUB&gt;VN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Input rated frequency f&lt;SUB&gt;LN&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;Rated fundamental AC voltage U on the load side&lt;SUB&gt;aN1&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;Output (working) frequency range&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-3.7NG/2.2NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;3.7/2.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;10/6.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;9.1/5.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;built-in&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Optional parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;10%&quot;&gt;
&lt;P align=center&gt;G-type: 1.2I&lt;SUB&gt;aN&lt;/SUB&gt;/1min&lt;/P&gt;
&lt;P align=center&gt;H-type: 1.5I&lt;SUB&gt;aN&lt;/SUB&gt;/1min£» 2I&lt;SUB&gt;aN&lt;/SUB&gt;/2s&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-460V (-15%,+10%)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;50Hz/60Hz£¨&#177;5£¥£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3-phase (3-wire) 380-460V (-15%,+10%)&lt;/P&gt;
&lt;P align=center&gt;(Corresponding to the rated input voltage)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=17 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;1Hz¡«400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-5.5NG/3.7NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;5.5/3.7&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;15/10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;13/9.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-7.5NG/5.5NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;7.5/5.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;21/15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;18/13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-11NG/7.5NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;11/7.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;26/21&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;25/18&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-15NG/11NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;15/11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;35/26&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;32/25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-18.5NG/15NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;18.5/15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;41/35&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;39/32&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-22NG/18.5NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;22/18.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;47/41&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;45/39&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-30NG/22NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;30/22&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;63/47&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;60/45&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;external&lt;/P&gt;
&lt;P align=center&gt;(Optional parts)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-37NG/30NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;37/30&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;78/63&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;74/60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-45NG/37NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;45/37&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;95/78&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;90/74&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-55NG/45NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;55/45&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;116/95&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;110/90&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-75NG/55NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;75/55&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;158/116&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;150/110&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-90NG/75NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;90/75&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;162/158&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;178/150&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;Standard Configuration&lt;/P&gt;
&lt;P align=center&gt;(External)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-110NG/90NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;110/90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;214/162&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;214/178&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-132NG/110NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;132/110&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;247/214&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;257/214&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-160NG/132NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;160/132&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;294/247&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;304/257&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;CF1-200NG/160NH&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;200/160&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;369/294&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;P align=center&gt;380/304&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Input the rated current value as a reference, which varies with the impedance of the power supply side (including input reactors and wires).&lt;BR&gt;&lt;BR&gt;CF1-NH series universal frequency converter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]LAEG-VF31 series frequency converter </title>
           <link>http://www.91way.com/info_en/26120.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:04:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The AEG-VF31 series frequency converter is a high-performance open-loop vector type frequency converter designed specifically to drive low-voltage three-phase asynchronous motors, thereby enabling customers to achieve energy-saving and process improvement goals. The power range is from 1.5kW to 630kW, covering almost the entire power usage range of low-voltage three-phase asynchronous motors. Powerful software features and comprehensive protection and alarm settings make your speed control system simpler&lt;BR&gt;&lt;BR&gt;Features&lt;BR&gt;Frequency upper and lower limit operation: The upper and lower limit values of the frequency command can be set separately without adding peripheral devices to limit the motor speed.&lt;BR&gt;Carrier frequency: PWM modulation method, adjustable from 1.0 to 16kHz.&lt;BR&gt;Built in simple PLC: can automatically control the operation of the system according to the pre arranged running time, direction, and frequency.&lt;BR&gt;Automatic torque boost and automatic slip compensation function: compensates for the insufficient output torque when the frequency decreases.&lt;BR&gt;Torque limiting function: When there is a sudden load change, the high-precision torque limiting function under vector control is used to limit the output torque and protect the machinery.&lt;BR&gt;Maintain frequency command operation: temporarily maintain the rise/fall of frequency during acceleration or deceleration.&lt;BR&gt;Energy saving control: Always provide the motor with the voltage that maximizes its efficiency based on the load and speed.&lt;BR&gt;Automatic Voltage Regulation (AVR): It can automatically maintain a constant output voltage when the grid voltage changes.&lt;BR&gt;Jogging function: Jogging function is invalid during operation; During the jog process, the running function is invalid.&lt;BR&gt;Frequency jump control: prevents mechanical system vibration, automatically avoids resonance points during constant speed operation, and is also suitable for dead zone control.&lt;BR&gt;Over torque detection: If the torque generated by the motor exceeds the over torque detection value, the contact will &quot;close&quot;.&lt;BR&gt;Swing frequency function: Especially suitable for industries such as textiles and chemical fibers, as well as occasions that require lateral movement and winding functions.&lt;BR&gt;Fixed length function: Given length control function.&lt;BR&gt;Timing control: It can achieve timing control of the frequency converter without the need for peripheral devices.&lt;BR&gt;PID control: Integrated PID regulator with preset PID setpoint and Auto/Man. mode&lt;BR&gt;Sleep wake-up function: automatically starts or enters a sleep stop state according to the set value.&lt;BR&gt;The working voltage range is wide, and the load capacity is ensured through voltage reduction modulation technology at low voltages. To meet strict industrial standards for power grid surges (induced lightning strikes), power grid noise, and electrostatic anti-interference.&lt;BR&gt;The entire series of machines adopts an independent air duct design, making it easy to cope with harsh industrial environments.&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141206115622359.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 568px; HEIGHT: 855px&quot; border=0 hspace=0 alt=&quot;LAEG-VF31 series frequency converter technical parameters&quot; src=&quot;/upload2014/201412/20141206115622359.jpg&quot; width=568 height=855&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141206115631235.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 568px; HEIGHT: 709px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LAEG-VF31 series frequency converter&quot; src=&quot;/upload2014/201412/20141206115631235.jpg&quot; width=568 height=709&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]MKA50202-1 bistable switch </title>
           <link>http://www.91way.com/info_en/26105.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:04:00</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201411/20141130164118786.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 352px; HEIGHT: 424px&quot; border=0 hspace=0 alt=&quot;Technical parameters of MKA50202-1 bistable switch&quot; src=&quot;/upload2014/201411/20141130164118786.jpg&quot; width=352 height=424&gt;&lt;/A&gt;&lt;BR&gt;MKA50202-1 bistable switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]CN600900100 frequency converter </title>
           <link>http://www.91way.com/info_en/26104.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:50</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201411/20141130163830362.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 364px; HEIGHT: 653px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of CN600900100 frequency converter&quot; src=&quot;/upload2014/201411/20141130163830362.jpg&quot; width=364 height=653&gt;&lt;/A&gt;&lt;BR&gt;CN600900100 frequency converter&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]SRMP6C-A2/A3 Universal frequency converter </title>
           <link>http://www.91way.com/info_en/23506.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:41</pubDate>
           <comments></comments>
           <description>SRMP6C-A2/A3 Universal Frequency Converter Model and Meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201307/20130701210659189.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 450px; HEIGHT: 377px&quot; border=0 hspace=0 alt=&quot;SRMP6C-A2/A3 Universal Frequency Converter Model Description&quot; src=&quot;/upload2013/201307/20130701210659189.jpg&quot; width=450 height=377&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Product features&lt;BR&gt;SRMP6C-A2/A3 universal frequency converter has significant energy-saving effect, good speed regulation performance, stable operation, and motor soft start (no impact on equipment and power grid)&lt;BR&gt;It has the advantages of complete protection function, automatic fault diagnosis, and simple operation.&lt;BR&gt;Function range 0.75-315KW, output frequency: 0.5-400Hz;&lt;BR&gt;Using Intel 16 bit microcontroller motor specific microprocessor chip:&lt;BR&gt;Siemens IGBT modules from Germany, axial flow fans from Taiwan, and electrolytic capacitors from Japan;&lt;BR&gt;All main components are imported;&lt;BR&gt;Optimize space voltage vector SVPWM control, reduce harmonic output, and achieve low noise and silence;&lt;BR&gt;Wide voltage input design of 20%, very suitable for China's voltage situation;&lt;BR&gt;Powerful functionality and excellent cost performance ratio;&lt;BR&gt;Easy to install, simple to operate, one-year warranty, lifetime service. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Characteristics of SRMP6C-A2/A3 Universal Frequency Converter&lt;BR&gt;The output frequency range is 0.5-400Hz.&lt;BR&gt;Adopting optimized SPWM control technology to improve current waveform and reduce vibration during light load operation.&lt;BR&gt;Built in standard serial communication with EIRS485/RS422.&lt;BR&gt;Built in PID closed-loop control function.&lt;BR&gt;Multi functional input/output terminals with intelligent control features to meet different user needs.&lt;BR&gt;Capable of instant power outage restart, multi-stage speed setting, jump frequency setting,&lt;BR&gt;S-curve acceleration and deceleration, speed feedback control.&lt;BR&gt;It has comprehensive soft and hard protection functions.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-E700 Mitsubishi inverter </title>
           <link>http://www.91way.com/info_en/20147.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:33</pubDate>
           <comments></comments>
           <description>FR-E700 Mitsubishi inverter&lt;BR&gt;Power range: 0.1~15KW&lt;BR&gt;Advanced magnetic flux vector control, 200% torque output at 0.5Hz&lt;BR&gt;Expand PID, flexible PWM&lt;BR&gt;Built in Modbus RTU protocol&lt;BR&gt;Stop improving accuracy&lt;BR&gt;Add option card FR-A7NC, which can support CC Link communication&lt;BR&gt;Add option card FR-A7NL, which can support LONWorks communication&lt;BR&gt;Add option card FR-A7ND, which can support Deveice Net communication&lt;BR&gt;Add option card FR-A7NP, which can support Profibus DP communication&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-A740 Mitsubishi inverter </title>
           <link>http://www.91way.com/info_en/20146.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:24</pubDate>
           <comments></comments>
           <description>FR-A740 Mitsubishi inverter&lt;BR&gt;&lt;BR&gt;Power range: 0.4-500kW&lt;BR&gt;High precision torque/speed/position control can be achieved during closed-loop operation&lt;BR&gt;Sensorless vector control can achieve torque/speed control&lt;BR&gt;Built in PLC function (special model)&lt;BR&gt;Using long-life components with built-in EMC filters&lt;BR&gt;Powerful network communication capabilities, supporting protocols such as DeviceNet, Profibus DP, Modbus, etc&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-F740 Mitsubishi inverter </title>
           <link>http://www.91way.com/info_en/20145.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:16</pubDate>
           <comments></comments>
           <description>FR-F740 Mitsubishi inverter&lt;BR&gt;Power range: 0.75~630KW&lt;BR&gt;Simple magnetic flux vector control method achieves 120% output torque at 3Hz&lt;BR&gt;Adopting the optimal excitation control method to achieve higher energy-saving operation&lt;BR&gt;Built in PID, frequency converter/power frequency switching, and can achieve multi pump cycle operation function&lt;BR&gt;Built in independent RS485 communication port&lt;BR&gt;Use long-life components&lt;BR&gt;Built in noise filter (above 75K)&lt;BR&gt;Equipped with energy-saving monitoring function, the energy-saving effect is clear at a glance&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-D700 Mitsubishi inverter </title>
           <link>http://www.91way.com/info_en/20144.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:03:07</pubDate>
           <comments></comments>
           <description>FR-D700 Mitsubishi inverter&lt;BR&gt;1. Power range: 0.4~7.5KW&lt;BR&gt;2. Universal magnetic flux vector control, 150% torque output at 1Hz&lt;BR&gt;3. Use long-life components&lt;BR&gt;4. Built in Modbus RTU protocol&lt;BR&gt;5. Built in braking transistor&lt;BR&gt;6. Expand PID and triangular wave functions&lt;BR&gt;7. Equipped with safety stop function&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-A700 series frequency converter </title>
           <link>http://www.91way.com/info_en/20143.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:59</pubDate>
           <comments></comments>
           <description>FR-A700 Mitsubishi inverter features:&lt;BR&gt;The A700 product is suitable for various equipment with high load requirements, such as cranes, elevators, printing and packaging, printing and dyeing, material winding, and other general occasions. The Mitsubishi FR-A700 series frequency converter has a high level of driving performance.&lt;BR&gt;With a unique sensorless vector control mode, various mechanical devices can operate with high precision in ultra-low speed areas without the need for encoders.&lt;BR&gt;Equipped with torque mode control, and the torque limit function can be used in speed control mode.&lt;BR&gt;Equipped with vector control power (with encoder), the frequency converter can achieve position control, fast response, high-precision speed control (zero speed control, servo locking, etc.), and torque control.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]FR-F700 Mitsubishi inverter </title>
           <link>http://www.91way.com/info_en/20142.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:50</pubDate>
           <comments></comments>
           <description>The F700 Mitsubishi inverter is not only used in many general applications, but also particularly suitable for industries such as fans, water pumps, and air conditioners.&lt;BR&gt;The FR-F700 series products not only have the same conventional PID control function as other frequency converters, but also expand the multi pump control function.&lt;BR&gt;The optimal excitation control function can be used not only at constant speed, but also during acceleration and deceleration, which can further optimize the energy-saving effect.&lt;BR&gt;The newly developed energy-saving monitoring function can confirm the energy-saving effect through the operation panel, output terminals (terminals CA, AM), and communication, making the energy-saving effect clear at a glance.&lt;BR&gt;&lt;BR&gt;Detailed introduction:&lt;BR&gt;Power range: 0.75~630KW&lt;BR&gt;Simple magnetic flux vector control method achieves 120% output torque at 3Hz&lt;BR&gt;Adopting the optimal excitation control method to achieve higher energy-saving operation&lt;BR&gt;Built in PID, frequency converter/power frequency switching, and can achieve multi pump cycle operation function&lt;BR&gt;Built in independent RS485 communication port&lt;BR&gt;Use long-life components&lt;BR&gt;Built in noise filter (above 75K)&lt;BR&gt;&lt;BR&gt;FR-F700 Mitsubishi inverter features:&lt;BR&gt;&lt;BR&gt;More energy-efficient.&lt;BR&gt;Environmentally friendly, long-lasting, and easy to maintain.&lt;BR&gt;The most suitable fan and pump.&lt;BR&gt;Easy to operate and networked.&lt;BR&gt;Applicable to globalization.&lt;BR&gt;Rich and colorful functions.</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]6SE7440 series Siemens frequency converter </title>
           <link>http://www.91way.com/info_en/20127.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:42</pubDate>
           <comments></comments>
           <description>6SE7440 series Siemens frequency converter&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]6SE6420 series Siemens universal frequency converter </title>
           <link>http://www.91way.com/info_en/20126.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:33</pubDate>
           <comments></comments>
           <description>6SE6420 series Siemens universal frequency converter&lt;BR&gt;&lt;BR&gt;Siemens Universal Frequency Converter MICROMASTER 420 Series&lt;BR&gt;Order number, technical specifications, rated power (KW), external dimensions W x H x D (mm), power supply voltage 200V~240V 3AC without built-in filter&lt;BR&gt;6SE6 420-2UC13-7AA1 0.37 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UC15-5AA1 0.55 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UC17-5AA1 0.75 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UC21-1BA1 1.1 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UC21-5BA1 1.5 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UC22-2BA1 2.2 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UC23-0CA1 3.0 KW 185 x 245 x 195&lt;BR&gt;6SE6 420-2UC24-0CA1 4.0 KW 185 x 245 x 195&lt;BR&gt;6SE6 420-2UC25-5CA1 5.5 KW 185 x 245 x 195&lt;BR&gt;&lt;BR&gt;Power supply voltage 380V~480V 3AC without built-in filter&lt;BR&gt;6SE6 420-2UD13-7AA1 0.37 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UD15-5AA1 0.55 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UD17-5AA1 0.75 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UD21-1AA1 1.1 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UD21-5AA1 1.5 KW 73 x 173 x 149&lt;BR&gt;6SE6 420-2UD22-2BA1 2.2 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UD23-0BA1 3.0 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UD24-0BA1 4.0 KW 149 x 202 x 172&lt;BR&gt;6SE6 420-2UD25-5CA1 5.5 KW 185 x 245 x 195&lt;BR&gt;6SE6 420-2UD27-5CA1 7.5 KW 185 x 245 x 195&lt;BR&gt;6SE6 420-2UD31-1CA1 11.0 KW 185 x 245 x 195&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]TS2000 series frequency converter </title>
           <link>http://www.91way.com/info_en/17493.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:25</pubDate>
           <comments></comments>
           <description>TS2000 series frequency converter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=3&gt;
&lt;P align=left&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;specification&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=11 width=30&gt;
&lt;P align=left&gt;output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Rated output voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Single phase 220V, three-phase 380V, 660V (maximum output voltage is the same as input power supply voltage)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=102 colSpan=2&gt;
&lt;P align=left&gt;Applicable motor power (kW)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;zero point four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;thirty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;ninety-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;two hundred and eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;zero point seven five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;eighteen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=39&gt;
&lt;P align=left&gt;Rated output current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=64&gt;
&lt;P align=left&gt;220V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;two point four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;three hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;four point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;seventy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;one hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;four hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=64&gt;
&lt;P align=left&gt;380V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;three hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;five hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;two point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;five point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;thirty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;four hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=64&gt;
&lt;P align=left&gt;660V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;twenty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;ninety-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;three hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;P align=left&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38 colSpan=2&gt;
&lt;P align=left&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;thirty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=left&gt;fifty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;eighty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;one hundred and seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=left&gt;two hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=57&gt;
&lt;P align=left&gt;three hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;quota&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;100% continuous&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Maximum overload current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;150% 1 minute, 180% 2 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P align=left&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Rated input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Single phase 220V, three-phase 380V, 660V &#177; 20%, 50-60Hz &#177; 5%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=16 width=30&gt;
&lt;P align=left&gt;Control and operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Output voltage self adjustment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;When the AVR function is effective, the output voltage remains basically unchanged when the input voltage changes&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Control method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Optimizing Space Vector PWM Control&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Frequency control range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;0¡«400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Output frequency accuracy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;&#177; 0.1% of the maximum frequency value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Output frequency resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;0.01Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Voltage/frequency characteristics&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Rated voltage adjustable from 50% to 100%, fundamental frequency adjustable from 50Hz to 400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Torque increase&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;21 torque boost curves to choose from&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Acceleration and deceleration characteristics&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;0.1 seconds to 3600 seconds (program can run for up to 36000 seconds)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Braking torque&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Within 22kW&amp;gt;20%, above 30kW&amp;gt;15%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Frequency setting input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Keyboard, keyboard potentiometer, 0-5V, 0-10V, 4-20mA, and 11 combinations with each other, serial communication settings on the upper computer, built-in PI regulator&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Input command signal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;19 optional functions including operation, forward/reverse, 6-channel programmable input terminals, forward/reverse jog, multi-stage speed, multi-stage acceleration/deceleration time, free parking, reset, voltage/current switching, etc&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;PG signal input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;PGA+, PGA -, PGB+, PGB differential input/PGA -, PGB open collector input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Serial communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;RS485/RS232 interface&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;standard functions&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Current limiting, torque boost, speed tracking, DC braking, instantaneous power outage restart, frequency upper and lower limit limits, slip compensation, automatic fault reset, bias frequency, starting frequency, jump frequency, frequency gain, carrier frequency adjustment, adjustable acceleration/deceleration mode, voltmeter and ammeter output, multi-stage speed, program operation, swing frequency operation, PID control, RS-485 interface, proportional linkage, remote control&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;protection function&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Overvoltage, undervoltage, overcurrent, current limiting, overheating, electronic thermal overload relay, overvoltage stall, data protection&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;output signal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Fault relay signal; Programmable open collector output, 14 functions to choose from; Output frequency synchronization signal: DC 0-10V, with 4 optional functions&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=30&gt;
&lt;P align=left&gt;display&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=102 colSpan=2&gt;
&lt;P align=left&gt;keyboard&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=174 colSpan=5&gt;
&lt;P align=left&gt;Parameter Settings&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=261 colSpan=8&gt;
&lt;P align=left&gt;Function code, data, status&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=174 colSpan=5&gt;
&lt;P align=left&gt;Run display&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=174 colSpan=5&gt;
&lt;P align=left&gt;fault display&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=30&gt;
&lt;P align=left&gt;Terms of Use&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Installation site&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Indoor, altitude not exceeding 1000 meters, dust-free, non corrosive gases, no direct sunlight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Applicable Environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;-10 &#176; C to+40 &#176; C (-10 &#176; C to+50 &#176; C for bare metal), 20% to 90% RH (no condensation)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;vibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Less than 0.5g&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Storage method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;-25&#176;C¡«+65&#176;C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102 colSpan=2&gt;
&lt;P align=left&gt;Installation method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;Wall mounted, floor standing electrical control cabinet type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=3&gt;
&lt;P align=left&gt;Protection level&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;IP20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=3&gt;
&lt;P align=left&gt;cooling method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=435 colSpan=13&gt;
&lt;P align=left&gt;0.75kW and below are enclosed self cooling, while others are forced air cooling&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;TS2000 series frequency converter&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]TS3000 series frequency converter </title>
           <link>http://www.91way.com/info_en/17492.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:16</pubDate>
           <comments></comments>
           <description>TS3000 series frequency converter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 96%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;96%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P align=center&gt;Standardization&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Rated output voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P align=center&gt;Three phase 380V (maximum output voltage is the same as input power supply voltage)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Rated output power of adaptive motor (KW)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;zero point seven five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two point two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;five point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;eighteen point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;two hundred and eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;seven point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Rated output current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;three hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;four hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;five hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;three point seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;forty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;P align=center&gt;three hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;P align=center&gt;four hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Continuous operating current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;100% rated output current&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;150% rated output current for 2 minutes, 180% rated output current for 10 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;output frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;0Hz~400Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Rated input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Three phase 380V &#177; 20%, 50~60Hz &#177; 5%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;modulation scheme&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Optimizing Space Voltage Vector PWM Modulation Mode&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Control method&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;There is PG feedback vector control; No PG feedback vector control; V/F control&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Given method for running commands&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Keyboard given; External terminal given; Given by the upper computer through the serial communication port&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Speed setting method&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Keyboard numeric settings; Simulation setting; Serial communication settings for the upper computer; Six methods including pulse frequency setting&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Speed setting resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Digital setting: 0.01Hz&lt;BR&gt;Simulation setting: 1/1000 maximum frequency&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Accuracy of speed setting&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Digital setting: &#177; 0.01% maximum frequency (-10 ¡æ~+40 ¡æ);&lt;BR&gt;Simulation setting: &#177; 0.05% maximum frequency (25 ¡æ&#177; 10 ¡æ)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Speed control accuracy&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;PG feedback vector control: &#177; 0.05% rated speed; £¨25¡æ&#177;10¡æ£©&lt;BR&gt;Non PG feedback vector control: &#177; 0.5% rated speed; £¨25¡æ&#177;10¡æ£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Speed control range&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;PG feedback vector control: 1:1000;&lt;BR&gt;No PG feedback vector control: 1:100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Torque control response&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;PG feedback vector control:&amp;lt;150mS;&lt;BR&gt;No PG feedback vector control:&amp;lt;200mS&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Starting torque&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;PG feedback vector control: 200% rated output torque/0.05Hz;&lt;BR&gt;No PG feedback vector control: 150% rated output torque/0.5Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Braking torque&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Energy free braking:&amp;gt;20% rated output torque within 22KW,&amp;gt;15% rated output torque above 30KW&lt;BR&gt;Energy consuming braking:&amp;gt;150% rated output torque&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Torque control accuracy&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;&#177; 5% rated output torque&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Set reference voltage output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;1 route,+10V, 5mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Control voltage source output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;24 V£¬100mA£» It can also be provided externally through PLC terminals&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;External user power input&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;1 way, the working power supply of the contact input terminal can use an external active contact power supply (12-24V)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;analog output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;1 channel, 0~10V, programmable output, multiple output options available&lt;BR&gt;1 channel, 0~10V/0-20mA, programmable output, multiple output options available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Programmable contact input&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;7-channel programmable, with 27 optional functions including forward/reverse, forward/reverse jog, multi-stage speed, multi-stage acceleration/deceleration time, free parking, voltage/current switching, etc&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Pulse signal input&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;1 channel, 0~50K HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;PG signal input&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;A+, A -, B+, B - differential input; A -, B - Open collector code wheel input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;FAM frequency signal output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;1 channel, frequency meter signal (output frequency is the multiplier signal of the frequency converter output frequency), 0-50kHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Open collector output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;2 channels, 24 operating states to choose from; Maximum output current 50mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Programmable relay output&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;2 channels, 24 operating states to choose from, contact capacity: 250V AC/3A or 30V DC/1A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Serial communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;RS-485 interface&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;standard functions&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Current limiting, torque boost, speed tracking, DC braking, power outage restart, slip compensation, automatic fault reset, frequency upper and lower limit limits, bias frequency, starting frequency, jump frequency, frequency gain, carrier frequency adjustment, adjustable acceleration/deceleration mode, voltmeter output, ammeter output, multi-stage speed, program operation, swing frequency operation, PI closed-loop operation, proportional linkage, remote control, forward and reverse dead zone&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;protection function&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Overvoltage, undervoltage, overcurrent, current limiting, overload, overheating, electronic thermal overload relay, overvoltage stall, data protection, etc&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Four digit digital display (LED)&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Set 16 state parameters including frequency, output frequency, output voltage, output current, motor speed, output torque, switch terminal, programming menu parameters, and 31 fault codes&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Chinese LCD display&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Control mode, current programming or monitoring parameter name, alarm content, keyboard operation guidance, etc&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Indicator light (LED)&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Parameter units, RUN/STOP status, etc&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;Terms of Use&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;Installation site&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Indoor, altitude not exceeding 1000 meters, dust-free, non corrosive gases, no direct sunlight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;Applicable Environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;-10 ¡æ~+40 ¡æ (bare machine -10 ¡æ~+50 ¡æ), 20%~90% RH (no condensation)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;vibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Less than 0.5g&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;Storage method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;-25¡æ~+65¡æ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;Installation method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;Wall mounted, floor standing electrical control cabinet type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;Protection level&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;IP20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=&quot;20%&quot; colSpan=2&gt;
&lt;P&gt;cooling method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;79%&quot; colSpan=12&gt;
&lt;P&gt;0.75KW and below are enclosed self cooling, while others are forced air cooling&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;TS3000 series frequency converter&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]B series explosion-proof frequency converter (II B) </title>
           <link>http://www.91way.com/info_en/13667.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:02:08</pubDate>
           <comments></comments>
           <description>1¡¢ Scope of application:&lt;BR&gt;&lt;BR&gt;The BQXB series explosion-proof frequency converter (IIB) is suitable for hazardous areas in Zone 1 and Zone 2;&lt;BR&gt;Class IIA and IIB explosive gas environment.&lt;BR&gt;&lt;BR&gt;2¡¢ BQXB series explosion-proof frequency converter (IIB) model meaning:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201006/20100606074546533.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 382px; HEIGHT: 275px&quot; border=0 hspace=0 alt=&quot;BQXB series explosion-proof frequency converter (IIB) model description&quot; src=&quot;/upload2010/201006/20100606074546533.jpg&quot; width=382 height=275&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Product features:&lt;BR&gt;&lt;BR&gt;The BQXB motor variable frequency speed control box adjusts the speed of ordinary three-phase asynchronous motors by changing their output frequency to meet the requirements of production processes or achieve energy-saving goals. The energy-saving rate can reach 30% -60%. It can also be used as a soft start controller for motors, forming a closed-loop speed control system through control circuits such as sensors and transmitters. The installation operation is simple, the starting balance has no impact current (soft start), the power capacity is greatly reduced, the power factor is constant, and it also has various functions such as fault display.&lt;BR&gt;1) Overcurrent protection, short circuit protection, overvoltage protection, undervoltage protection, instantaneous power outage protection, phase failure protection;&lt;BR&gt;2) Digital display or indication or pointer display of frequency, speed, load rate or current, etc;&lt;BR&gt;3) The frequency can be manually adjusted, the process curve of the speed changing over time can be set, and the frequency can also be controlled by a signal provided by the DCS system; This speed control frequency converter is an imported component. Inside the cabinet, there are also ammeters, voltmeters, automatic air switches, indicator lights, AC contactors, power frequency conversion switches, and start and stop buttons. Various appropriate operating methods can be designed, selected, and configured according to the process requirements of different users.&lt;BR&gt;4) Both steel pipes and cables can be used for wiring.&lt;BR&gt;5) Meets the requirements of GB3836-2000 and IEC60D79 standards.&lt;BR&gt;&lt;BR&gt;4¡¢ Technical parameters of BQXB series explosion-proof frequency converter (IIB):&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201006/20100606074613501.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 180px&quot; border=0 hspace=0 alt=&quot;Technical parameters of BQXB series explosion-proof frequency converter (IIB)&quot; src=&quot;/upload2010/201006/20100606074613501.jpg&quot; width=680 height=180&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Variable Frequency Drive (VFD)]TPB Fully automatic variable frequency speed control cabinet </title>
           <link>http://www.91way.com/info_en/6608.html</link>
           <author></author>
           <guid></guid>
           <category>Variable Frequency Drive (VFD)</category>
           <pubDate>2026-6-11 11:01:59</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;The TPB fully automatic variable frequency speed control cabinet fully absorbs advanced experience in water pump control at home and abroad. After years of production and application, it has been continuously improved and optimized, and carefully designed and manufactured.&lt;BR&gt;TPK products have multiple protection functions such as overload, short circuit, phase loss protection, pump leakage, motor overheating and leakage, as well as complete status display. They also have single pump and multi pump control working modes, multiple main and backup pump switching modes, and various starting modes. It can be widely used for automatic control in various occasions such as water supply, drainage, fire protection, sprinkler network pressurization, HVAC cold and hot water circulation in industrial and agricultural production and various buildings.&lt;BR&gt;The BOFA series water pump control cabinet has excellent internal quality, beautiful and durable appearance, and easy installation and operation, making it a safe and reliable companion for various types of water pumps.&lt;BR&gt;Product Features:&lt;BR&gt;1. Widely used: There are corresponding specialized models and specifications for various occasions, such as domestic water supply and drainage, fire protection, sprinkler, pressurization, air conditioning cooling circulation, industrial control pumps, sewage discharge. Control the motor power range from 0.18 to 250 kW.&lt;BR&gt;2. Excellent Quality: Carefully designed and crafted with international and domestic renowned electrical components and high-quality standard cabinets.&lt;BR&gt;3. Versatile functions: From one control to five control, the main and backup pumps can be freely selected and combined, with multiple starting methods and various control forms. Automatic fault switching. We can also design it specifically for you.&lt;BR&gt;Technical parameters of TPB fully automatic variable frequency speed control cabinet:&lt;BR&gt;1. QZD direct start control cabinet&lt;BR&gt;Motor power: 0.37-15KW;&lt;BR&gt;Voltage: 380V;&lt;BR&gt;Number of water pumps: 1-4.&lt;BR&gt;</description>
       </item>
</channel>
</rss>

