           <title>[High voltage grounding switch]MZD66-12/40 Indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/22537.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:25:20</pubDate>
           <comments></comments>
           <description>The MZD66-12/40 (prototype number JN15-12/40) indoor high-voltage grounding switch is a new type of grounding switch designed and developed by our company based on the ES1 grounding switch prototype, which has international advanced level. The structural form is a combination type, and its performance meets the requirements of GB1985-89 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot; and EC129. It is suitable for indoor 3-10 kV three-phase AC 50 (60) Hz power systems; It has a certain closing ability to protect other electrical equipment inside the switchgear from damage, and can be used in conjunction with various high-voltage switchgear as grounding protection during maintenance of high-voltage electrical equipment.&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;Advanced design, indoor load switch; Simple structure, easy installation and adjustment; Having the ability to quickly separate and merge; Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ; Altitude: not exceeding 1000 meters; Humidity conditions: The average daily relative humidity should not exceed 95%, and the average monthly relative humidity should not exceed 90%; Seismic intensity: not exceeding 8 degrees; Pollution level: Level II.&lt;BR&gt;&lt;BR&gt;MZD66-12 indoor high-voltage grounding switch model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130203220027160.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 291px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD66-12 Indoor High Voltage Grounding Switch Model Description&quot; src=&quot;/upload2013/201302/20130203220027160.gif&quot; width=291 height=170&gt;&lt;/A&gt;&lt;BR&gt;Main technical parameters of MZD66-12 indoor high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-time withstand current (thermal stability)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-circuit closing current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated peak withstand current (dynamic stability)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;DIV align=left&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=199&gt;
&lt;DIV align=left&gt;Rated short-time power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=89&gt;
&lt;DIV align=center&gt;Relatively and alternately&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;forty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated lightning impulse withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;MZD66-12 Indoor High Voltage Grounding Switch Dimensions and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130203220150936.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 342px; WIDTH: 515px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD66-12 Indoor High Voltage Grounding Switch Dimensions&quot; src=&quot;/upload2013/201302/20130203220150936.gif&quot; width=515 height=342&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130203220204950.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 304px; WIDTH: 347px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of MZD66-12 indoor high-voltage grounding switch&quot; src=&quot;/upload2013/201302/20130203220204950.gif&quot; width=347 height=304&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Copper bar wiring terminal diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130203220234744.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 512px; WIDTH: 406px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD66-12 Indoor High Voltage Grounding Switch Terminal Wiring Diagram&quot; src=&quot;/upload2013/201302/20130203220234744.gif&quot; width=406 height=512&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Installation Hole Diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130203220251649.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 277px; WIDTH: 421px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD66-12 Indoor High Voltage Grounding Switch Installation Hole Diagram&quot; src=&quot;/upload2013/201302/20130203220251649.gif&quot; width=421 height=277&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=81&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;DIV align=center&gt;F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;G&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;MZD66-12/40-210&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;MZD66-12/40-220&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;MZD66-12/40-230&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and ninety-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and fifty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;MZD66-12/40-250&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and ninety-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;MZD66-12/40-275&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and forty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]MZD81-40.5/31.5 Indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/22538.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:24:58</pubDate>
           <comments></comments>
           <description>MZD81-40.5/31.5 indoor high-voltage grounding switch (hereinafter referred to as grounding switch) is an advanced level product with high technical parameter performance developed by Xi'an High Voltage Apparatus Research Institute. After comprehensive assessment, its performance meets the requirements of the national standard GB1985 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot;, suitable for 40.5kV, AC 50Hz power systems, and can be used in conjunction with KYN ¡õ -45 and other types of high-voltage switches. It can also be used as grounding protection for high-voltage electrical equipment maintenance.&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;Advanced design, indoor load switch; Simple structure, easy installation and adjustment; Having the ability to quickly separate and merge; The upper limit of air temperature around an altitude not exceeding 1000 meters plus 40 degrees Celsius; The lower limit is -10 degrees, and the earthquake intensity does not exceed 8 degrees. There is no risk of flooding, explosion, severe dust, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;MZD81-40.5 indoor high-voltage grounding switch model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130204085411164.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 191px; WIDTH: 364px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD81-40.5 Indoor High Voltage Grounding Switch Model Description&quot; src=&quot;/upload2013/201302/20130204085411164.gif&quot; width=364 height=191&gt;&lt;/A&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;maximum voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Thermal stability voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Thermal stability current time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Short circuit closing current&lt;/TD&gt;
&lt;TD&gt;KA&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Dynamic stable current&lt;/TD&gt;
&lt;TD&gt;KA&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Center distance between poles&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=72&gt;
&lt;DIV align=left&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=199&gt;
&lt;DIV align=left&gt;Rated short-time power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=89&gt;
&lt;DIV align=center&gt;Extreme to ground and between poles&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated lightning impulse withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;MZD81-40.5 Indoor High Voltage Grounding Switch Dimensions and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130204085458257.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 358px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD81-40.5 Indoor High Voltage Grounding Switch Dimensions&quot; src=&quot;/upload2013/201302/20130204085458257.gif&quot; width=550 height=358&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130204085507671.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 403px; WIDTH: 296px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation Structure Diagram of MZD81-40.5 Indoor High Voltage Grounding Switch&quot; src=&quot;/upload2013/201302/20130204085507671.gif&quot; width=296 height=403&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130204085522309.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 266px; WIDTH: 535px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MZD81-40.5 indoor high-voltage grounding switch opening size&quot; src=&quot;/upload2013/201302/20130204085522309.gif&quot; width=535 height=266&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Pole spacing B&lt;/TD&gt;
&lt;TD&gt;H&lt;/TD&gt;
&lt;TD&gt;A (installation hole for channel steel back)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three hundred&lt;/TD&gt;
&lt;TD&gt;seven hundred and ninety&lt;/TD&gt;
&lt;TD&gt;3 holes -15 * 400 * 14 (diameter)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;eight hundred and ninety&lt;/TD&gt;
&lt;TD&gt;3 holes -15 * 400 * 14 (diameter)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;nine hundred and ninety&lt;/TD&gt;
&lt;TD&gt;3 holes -15 * 400 * 14 (diameter)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Ordering Instructions&lt;BR&gt;Please specify the product model, rated voltage, thermal stability current, and phase to phase distance.&lt;BR&gt;A shaft operating mechanism is required, and the right or left operating direction as shown in the above figure should be indicated with the corresponding right or left operating mechanism.&lt;BR&gt;When a sensor powered display device is required, please indicate the type of display.&lt;BR&gt;Users have special requirements that can be resolved through negotiation.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN4-40.5 Indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/26021.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:24:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185037310.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 468px; WIDTH: 605px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JN4-40.5 indoor AC high-voltage grounding switch&quot; src=&quot;/upload2014/201410/20141004185037310.gif&quot; width=605 height=468&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185045687.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 362px; WIDTH: 605px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JN4-40.5 indoor AC high-voltage grounding switch&quot; src=&quot;/upload2014/201410/20141004185045687.gif&quot; width=605 height=362&gt;&lt;/A&gt;&lt;BR&gt;JN4-40.5 Indoor AC High Voltage Grounding Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN2-12,JN2-12(Z) Indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/26022.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:24:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185230768.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 501px; WIDTH: 605px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN2-12 JN2-12 (Z) Indoor AC High Voltage Grounding Switch Technical Parameters&quot; src=&quot;/upload2014/201410/20141004185230768.gif&quot; width=605 height=501&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185237999.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 416px; WIDTH: 605px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN2-12 JN2-12 (Z) Indoor AC High Voltage Grounding Switch Installation Dimensions&quot; src=&quot;/upload2014/201410/20141004185237999.gif&quot; width=605 height=416&gt;&lt;/A&gt;&lt;BR&gt;JN2-12 JN2-12 (Z) Indoor AC High Voltage Grounding Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN12-40.5/31.5 type indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/27671.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:23:57</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JN12-40.5/31.5 indoor high-voltage grounding switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JNA-12/S High Voltage Grounding Switch </title>
           <link>http://www.91way.com/info_en/27464.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:23:48</pubDate>
           <comments></comments>
           <description>JNA-12/S-type high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;The JNA-12/S series indoor high-voltage grounding switch (referred to as the grounding switch) is a brand new product developed to match our factory's high-voltage switchgear. It can also be matched with various other models of high-voltage switchgear. Its performance meets the requirements of GB1985-89 (AC high-voltage isolation switch and grounding switch), with advanced design, reliable technical performance, simple structure, easy installation and commissioning, and is equipped with high-voltage live display device.&lt;BR&gt;&lt;BR&gt;Technical parameters of JNA-12/S-type high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot; align=middle&gt;Product model and specifications&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;Rated&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;voltage&lt;/P&gt;
&lt;P&gt;£¨kV£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;highest&lt;/P&gt;
&lt;P&gt;Work&lt;/P&gt;
&lt;P&gt;voltage&lt;/P&gt;
&lt;P&gt;£¨kV£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;4S hot&lt;/P&gt;
&lt;P&gt;stable&lt;/P&gt;
&lt;P&gt;electric current&lt;/P&gt;
&lt;P&gt;£¨kA£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;
&lt;P&gt;Dynamic stability&lt;/P&gt;
&lt;P&gt;Current&lt;/P&gt;
&lt;P&gt;(Net worth)&lt;/P&gt;
&lt;P&gt;£¨kA£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;
&lt;P&gt;Close the door&lt;/P&gt;
&lt;P&gt;Current&lt;/P&gt;
&lt;P&gt;(Net worth)&lt;/P&gt;
&lt;P&gt;£¨kA£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;Rated&lt;/P&gt;
&lt;P&gt;Insulation&lt;/P&gt;
&lt;P&gt;Level&lt;/P&gt;
&lt;P&gt;£¨kV£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;alternate&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;distance&lt;/P&gt;
&lt;P&gt;£¨mm£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;link together&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;speed&lt;/P&gt;
&lt;P&gt;£¨m/s£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;
&lt;P align=left&gt;main circuit&lt;/P&gt;
&lt;P align=left&gt;Contact&lt;/P&gt;
&lt;P align=left&gt;Resistance&lt;/P&gt;
&lt;P align=left&gt;£¨¦Ì¦¸£©&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/S25-210&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;eleven point five&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD vAlign=center rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=bottom rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;two hundred and ten&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;CENTER&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;CENTER&gt;&lt;/CENTER&gt;
&lt;P align=left&gt;¡Ý5&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot; align=left&gt;
&lt;P&gt;&amp;lt;120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/31.5-210&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/S25-220&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;eleven point five&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD vAlign=center rowSpan=2 width=&quot;8%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=bottom rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;two hundred and ten&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;¡Ý5&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot; align=left&gt;
&lt;P&gt;&amp;lt;120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/S31.5-220&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=19 width=&quot;20%&quot;&gt;JNA-12/S25-250&lt;/TD&gt;
&lt;TD height=37 rowSpan=2 width=&quot;8%&quot; align=middle&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;eleven point five&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD vAlign=center rowSpan=2 width=&quot;8%&quot;&gt;
&lt;P&gt;42&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=bottom rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;two hundred and ten&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;¡Ý5&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot; align=left&gt;&amp;lt;120&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;JNA-12/31.5-250&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/S25-275&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;ten&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;eleven point five&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;twenty-five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD vAlign=center rowSpan=2 width=&quot;8%&quot;&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=bottom rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;two hundred and ten&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot; align=middle&gt;
&lt;P&gt;¡Ý5&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot; align=left&gt;
&lt;P&gt;&amp;lt;120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;JNA-12/31.5-275&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;&lt;/CENTER&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15A-12(EK6) indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/389.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:23:19</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JN15A-12 (EK6) indoor high-voltage grounding switch is an indoor product manufactured directly by introducing advanced technology from abroad. It is suitable for use as grounding protection in power systems with AC 50Hz and rated voltage of 12kV, and has corresponding short-circuit closing capability. This grounding switch is a split type with moving and stationary contacts, and can be used in conjunction with various types of metal enclosed switchgear in China according to different installation needs.&lt;BR&gt;&lt;BR&gt;Product Features:&lt;BR&gt;1. Advanced design and reliable technical performance;&lt;BR&gt;2. Simple structure, easy installation and debugging;&lt;BR&gt;3. Quick opening and closing, with the ability to close;&lt;BR&gt;4. Beautiful appearance and excellent manufacturing process;&lt;BR&gt;5. Scientific and practical, can be operated on both sides;&lt;BR&gt;6. It can be formal or inverted.&lt;/P&gt;
&lt;P align=center&gt;JN15A-12 Indoor AC High Voltage Grounding Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]MZD65-12 type indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/22536.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:23:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MZD65-12 indoor high-voltage grounding switch is an advanced product developed by integrating the latest technology of domestic and foreign grounding switches. After comprehensive assessment, its performance meets the requirements of GB1985-89 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot; and IEC129. It is suitable for power systems with AC 50Hz of 12kV and below, and can be used in conjunction with various types of high-voltage switchgear for grounding protection.&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;1. Advanced design, indoor load switch; 2. Simple structure, easy installation and adjustment; 3. Having the ability to quickly separate and merge;&lt;BR&gt;&lt;BR&gt;Model meaning&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130203215415504.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 285px; HEIGHT: 171px&quot; border=0 hspace=0 alt=&quot;Model Description of MZD65-12 Indoor High Voltage Grounding Switch&quot; src=&quot;/upload2013/201302/20130203215415504.gif&quot; width=285 height=171&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Working and environmental conditions&lt;BR&gt;1. Altitude not exceeding 1000m;&lt;BR&gt;2. Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ;&lt;BR&gt;3. Allow storage and transportation at 30 ¡æ;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. No flammable, explosive, severe dust, chemical corrosion, or severe vibration areas.&lt;BR&gt;&lt;BR&gt;Main technical parameters of MZD65-12 indoor high-voltage grounding switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130203215442141.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 575px; HEIGHT: 118px&quot; border=0 hspace=0 alt=&quot;Technical parameters of MZD65-12 indoor high-voltage grounding switch&quot; src=&quot;/upload2013/201302/20130203215442141.jpg&quot; width=575 height=118&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;MZD65-12 Indoor High Voltage Grounding Switch Appearance and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2013/201302/20130203215457892.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 201px; HEIGHT: 159px&quot; border=0 hspace=0 alt=&quot;MZD65-12 Indoor High Voltage Grounding Switch Dimensions 1&quot; src=&quot;/upload2013/201302/20130203215457892.gif&quot; width=201 height=159&gt;&lt;/A&gt;&lt;A href=&quot;/upload2013/201302/20130203215503109.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 185px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;MZD65-12 Indoor High Voltage Grounding Switch Dimensions 2&quot; src=&quot;/upload2013/201302/20130203215503109.gif&quot; width=185 height=170&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130203215514194.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 173px; HEIGHT: 114px&quot; border=0 hspace=0 alt=&quot;MZD65-12 indoor high-voltage grounding switch installation size 1&quot; src=&quot;/upload2013/201302/20130203215514194.gif&quot; width=173 height=114&gt;&lt;/A&gt;&lt;A href=&quot;/upload2013/201302/20130203215523185.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 364px; HEIGHT: 90px&quot; border=0 hspace=0 alt=&quot;MZD65-12 Indoor High Voltage Grounding Switch Installation Dimensional Table&quot; src=&quot;/upload2013/201302/20130203215523185.gif&quot; width=364 height=90&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2013/201302/20130203215544466.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 221px; HEIGHT: 140px&quot; border=0 hspace=0 alt=&quot;MZD65-12 indoor high-voltage grounding switch installation size 2&quot; src=&quot;/upload2013/201302/20130203215544466.gif&quot; width=221 height=140&gt;&lt;/A&gt;&lt;A href=&quot;/upload2013/201302/20130203215551139.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 222px; HEIGHT: 104px&quot; border=0 hspace=0 alt=&quot;MZD65-12 indoor high-voltage grounding switch installation size 3&quot; src=&quot;/upload2013/201302/20130203215551139.gif&quot; width=222 height=104&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JW1-40.5 outdoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/16562.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JW1-40.5 outdoor high-voltage grounding switch is suitable for grounding protection during equipment maintenance in high-voltage lines below 40.5kV. Usually used in conjunction with vertical isolation switches for upper busbar grounding, it can also be used as a transformer neutral point grounding switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;DIV&gt;
&lt;TABLE style=&quot;WIDTH: 85%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;85%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=144&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=144&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=96&gt;
&lt;DIV&gt;JW1-40.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=120&gt;
&lt;DIV&gt;40.5kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=144&gt;
&lt;DIV&gt;31.5kA&lt;/DIV&gt;
&lt;DIV&gt;40kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=144&gt;
&lt;DIV&gt;80kA&lt;/DIV&gt;
&lt;DIV&gt;100kA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-40.5/31.5 indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/12807.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:50</pubDate>
           <comments></comments>
           <description>JN15-40.5/31.5 indoor high-voltage grounding switch&lt;BR&gt;280, 300, 350&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN6-40.5 High Voltage Grounding Switch </title>
           <link>http://www.91way.com/info_en/16561.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:48</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;Rated short-circuit closing current&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;JN6-40.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;40.5kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;25kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;63kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV&gt;63kA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JN6-40.5 High Voltage Grounding Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]EK6-24 type indoor high-voltage grounding switch EK6-24/31.5£¬EK6-24/40</title>
           <link>http://www.91way.com/info_en/12808.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:39</pubDate>
           <comments></comments>
           <description>The EK6-24 indoor high-voltage grounding switch is suitable for use in three-phase AC 50Hz power systems of 24kV and below, as a grounding protection for high-voltage equipment maintenance. Used in conjunction with KYN28 (GZS1) central cabinet.&lt;BR&gt;&lt;BR&gt;EK6-24/31.5£¬EK6-24/40&lt;BR&gt;150, 210, 275&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-24/40 type indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/12806.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:22</pubDate>
           <comments></comments>
           <description>JN15-24/40 indoor high-voltage grounding switch&lt;BR&gt;210, 230, 250, 275&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN2-12 Indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/3791.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;/uploadfiles/200805/2008527205552173.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 734px; WIDTH: 561px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN2A-12 Indoor AC High Voltage Grounding Switch Appearance and Installation Dimensions&quot; src=&quot;/uploadfiles/200805/2008527205552173.jpg&quot; width=561 height=734&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;This product has been improved on the JN2-12 indoor high-voltage grounding switch and is mainly installed in the XGN2-12 box type fixed high-voltage cabinet or GG-1A (F) anti misoperation high-voltage switchgear.&lt;BR&gt;&lt;BR&gt;JN2A-12 Indoor AC High Voltage Grounding Switch Outline Drawing:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008527205727616.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 272px; WIDTH: 530px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN2A-12 Indoor AC High Voltage Grounding Switch Installation Dimensional Drawing&quot; src=&quot;/uploadfiles/200805/2008527205727616.gif&quot; width=530 height=272&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;L1&lt;/TD&gt;
&lt;TD height=60 rowSpan=3 width=&quot;20%&quot; align=center&gt;Equipped with GG-1A (F)&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD height=60 rowSpan=3 width=&quot;20%&quot; align=center&gt;Equipped with XGN2&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;L2&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;seven hundred&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;seven hundred and sixty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;L3&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;nine hundred&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=center&gt;nine hundred and twenty&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Technical parameters of JN2A-12 indoor AC high voltage grounding switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;Dynamic stability current kA (peak value)&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;4S thermal stability current kA (effective value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; align=center&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;JN2-12/31.5- ¡õ Ordinary porcelain bottle without display device&lt;BR&gt;JN2-12/31.5- (W) - ¡õ Passive epoxy insulator sensor with DXN ¡õ -12/¡õ&lt;BR&gt;JN2-12/31.5- (WQ) - ¡õ Passive epoxy full condition insulator sensor with DXN ¡õ -12/¡õ&lt;BR&gt;JN2-12/31.5- (Y) - ¡õ Ordinary porcelain bottle with display device GSN ¡õ -12/¡õ&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-24/31.5 type indoor high-voltage grounding switch 210¡¢230¡¢250¡¢275</title>
           <link>http://www.91way.com/info_en/12805.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:13</pubDate>
           <comments></comments>
           <description>JN15-24/31.5 indoor high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;Suitable for three-phase, AC 50Hz power systems of 24kV and below, it can be used as a separate maintenance protection switch for transformer rooms in substations, or as a manually operated mechanical grounding device to ensure personal safety during maintenance. It is usually used for central cabinets and various types of high-voltage switchgear.&lt;BR&gt;210, 230, 250, 275&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-12/50 type indoor high-voltage grounding switch 165¡¢180¡¢210¡¢230¡¢250¡¢275</title>
           <link>http://www.91way.com/info_en/12804.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:03</pubDate>
           <comments></comments>
           <description>The JN15-12 indoor high-voltage grounding switch (hereinafter referred to as the grounding switch) is a brand new product with international advanced level designed and developed based on the EK6 grounding switch of Germany's GALOR-EMAG company and the ES1 of Xi'an Senyuan company. Suitable for three-phase, AC 50Hz power systems of 12kV and below, it can be used as a separate maintenance protection switch for substation transformer rooms, or as a manually operated mechanical grounding device to ensure personal safety during maintenance. It is usually used for central cabinets and various types of high-voltage switchgear.&lt;BR&gt;JN15-12/50 indoor high-voltage grounding switch opening distance specification:&lt;BR&gt;&lt;BR&gt;165, 180, 210, 230, 250, 275&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN8-12(C) Indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/4084.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:22:02</pubDate>
           <comments></comments>
           <description>The JN8-12 (C) series indoor AC high voltage grounding switch is a single pole grounding switch used in circuit networks with rated voltage of 12KV and below AC 50Hz. It is a dedicated grounding switch used in conjunction with the GN19-12 (C) series high voltage switch for safe grounding during power outage maintenance.&lt;BR&gt;&lt;BR&gt;Main technical parameters of JN8-12 (C) indoor AC high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;model&lt;/TD&gt;
&lt;TD width=70 align=center&gt;Rated voltage (KV)&lt;/TD&gt;
&lt;TD width=97 align=center&gt;4s rated short-time withstand current (KA)&lt;/TD&gt;
&lt;TD width=100 align=center&gt;Rated peak withstand current (KA)&lt;/TD&gt;
&lt;TD width=173 align=center&gt;Model and specification of isolation switch&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12/12.5&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;twelve point five&lt;/TD&gt;
&lt;TD width=100 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12/400-12.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12C/12.5&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;twelve point five&lt;/TD&gt;
&lt;TD width=100 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12C/400-12.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12/20&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;twenty&lt;/TD&gt;
&lt;TD width=100 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12/630-20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12C/20&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;twenty&lt;/TD&gt;
&lt;TD width=100 align=center&gt;fifty&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12C/630-20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12/31.5&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=100 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12/1000-31.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12C/31.5&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;thirty-one point five&lt;/TD&gt;
&lt;TD width=100 align=center&gt;eighty&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12C/1000-31.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12/40&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;forty&lt;/TD&gt;
&lt;TD width=100 align=center&gt;one hundred&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12/1250-40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=171 align=center&gt;JN8-12C/40&lt;/TD&gt;
&lt;TD width=70 align=center&gt;twelve&lt;/TD&gt;
&lt;TD width=97 align=center&gt;forty&lt;/TD&gt;
&lt;TD width=100 align=center&gt;one hundred&lt;/TD&gt;
&lt;TD width=173 align=center&gt;GN19-12C/1250-40&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;Exterior installation dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200807/20087875820381.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 221px; WIDTH: 562px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN8-12 (C) Indoor AC High Voltage Grounding Switch Appearance and Installation Dimensions&quot; src=&quot;/uploadfiles/200807/20087875820381.jpg&quot; width=562 height=221&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201908/20190817144609931.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 372px; WIDTH: 321px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN8-12 (C) Indoor AC High Voltage Grounding Switch Outline Drawing&quot; src=&quot;/upload2019/201908/20190817144609931.jpg&quot; width=321 height=372&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JN8-12 (C) Indoor AC High Voltage Grounding Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN10-12 High voltage grounding switch </title>
           <link>http://www.91way.com/info_en/8357.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:21:55</pubDate>
           <comments></comments>
           <description>JN10-12 indoor AC high-voltage grounding switch is used in three-phase AC 50Hz, rated voltage 10kV power systems as a grounding device to ensure personal safety during maintenance.&lt;BR&gt;&lt;BR&gt;Characteristics of JN10-12 High Voltage Grounding Switch&lt;BR&gt;&lt;BR&gt;The grounding switch is a three-phase device, with three insulators installed on the chassis. The insulators are equipped with wiring terminals and grounding contacts, and the grounding switch is opened and closed by rotating the main shaft on the chassis. The grounding switch is equipped with a spring closing device, which is driven by an operating mechanism. When the spring energy is stored to a certain position, the spring energy is released to achieve rapid closing of the grounding switch. The grounding switch can be equipped with a high-voltage live display device, and can also be interlocked with its switch device to prevent misoperation.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN4-12 type indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/6811.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:21:46</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JN4-12/31.5 and JN4-12G indoor high-voltage grounding switches are a new type of grounding switch designed and developed with domestic standards. The structural form is assembled, and its performance meets the requirements of GB1985-89 &quot;AC High Voltage Disconnectors and Grounding Switches&quot; and IEC129. It is suitable for indoor 3-12KV three-phase AC 50Hz power systems. It has a certain closing ability to protect other electrical equipment inside the switchgear from damage. Can be used in conjunction with various high-voltage switchgear as grounding protection for high-voltage electrical equipment maintenance.&lt;BR&gt;JN4-12G indoor high-voltage grounding switch is the main component used for 12KV indoor AC metal armored movable metal enclosed switchgear and other high-voltage switchgear, and can also be used separately. Used for grounding protection in AC 50Hz power systems of 12kV and below. Capable of closing short-circuit current. Reasonable structure, small size, and flexible operation. Easy to install and adjust.&lt;BR&gt;&lt;BR&gt;2¡¢ Environmental conditions for the use of JN4-12 indoor high-voltage grounding switch&lt;BR&gt;Altitude: not exceeding 1000-3000m&lt;BR&gt;Surrounding air temperature: upper limit+40 ¡æ; Lower limit -25 ¡æ&lt;BR&gt;Seismic intensity: not exceeding 8 degrees&lt;BR&gt;There is no danger of fire, explosion, severe dust, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;3¡¢ Main technical data&lt;BR&gt;Rated voltage 12KV&lt;BR&gt;Thermal stability current 31.5 KA&lt;BR&gt;Thermal stability current time S 4&lt;BR&gt;Short circuit closing current 65/80 KA&lt;BR&gt;Dynamic stable current 80 KA&lt;BR&gt;Rated insulation level, power frequency withstand voltage, KV pole to ground and pole to pole 42&lt;BR&gt;Lightning impulse withstand voltage 75&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185533956.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 605px; HEIGHT: 415px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JN4-12 indoor high-voltage grounding switch&quot; src=&quot;/upload2014/201410/20141004185533956.gif&quot; width=605 height=415&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201410/20141004185627115.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 605px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JN4-12 indoor high-voltage grounding switch&quot; src=&quot;/upload2014/201410/20141004185627115.gif&quot; width=605 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201908/20190817144757231.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 376px; HEIGHT: 296px&quot; border=0 hspace=0 alt=&quot;Outline drawing of JN4-12 indoor high-voltage grounding switch&quot; src=&quot;/upload2019/201908/20190817144757231.jpg&quot; width=376 height=296&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]BR series grounding switch optional accessories </title>
           <link>http://www.91way.com/info_en/4319.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:21:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200808/20088198310640.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/uploadfiles/200808/20088198310640.jpg&quot; width=540&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200808/200881983113531.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 591px; HEIGHT: 403px&quot; border=0 hspace=0 alt=&quot;BR series grounding switch accessories appearance and installation dimensions&quot; src=&quot;/uploadfiles/200808/200881983113531.jpg&quot; width=591 height=403&gt;&lt;/A&gt;&lt;BR&gt;BR series grounding switch accessories&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN1-12 high-voltage single-phase grounding switch </title>
           <link>http://www.91way.com/info_en/1668.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:21:26</pubDate>
           <comments></comments>
           <description>JN1-12 high-voltage single-phase grounding switch is a single pole grounding switch used in circuit networks with rated voltage of 12KV and below AC 50HZ. It is a dedicated grounding switch used in conjunction with GN19-12 (C) series high-voltage isolating switches, and is used for safe grounding during power outage maintenance.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JW2-126/252 series high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/3628.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:21:11</pubDate>
           <comments></comments>
           <description>&lt;DIV&gt;Structure Introduction&lt;/DIV&gt;
&lt;DIV&gt;The JW2 series grounding switch consists of a grounding rod, a static contact, a pillar porcelain bottle, and a base. It has two steps of action: when closing, the blade first swings upwards, rotates a certain angle, and the moving contact collides with the stationary contact before rising and inserting into the stationary contact. When opening, the opposite is true. The grounding blade first shrinks downwards, causing the moving contact to pull out of the stationary contact and then swings downwards to reach the end point of opening. JW2 series grounding switch is equipped with CS9 manual operating mechanism.&lt;/DIV&gt;
&lt;DIV&gt;&lt;A href=&quot;/uploadfiles/200805/20085191589186.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 318px; HEIGHT: 204px&quot; border=0 hspace=0 alt=&quot;Model Description of JW2-126/252 Series High Voltage Grounding Switch&quot; src=&quot;/uploadfiles/200805/20085191589186.jpg&quot; width=318 height=204&gt;&lt;/A&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;BR&gt;Main technical parameters of JW2-126/252 series high-voltage grounding switch&lt;/DIV&gt;
&lt;DIV&gt;&lt;BR&gt;JW2-126&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;26%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated short-time&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated peak value&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;pressure resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;26%&quot;&gt;
&lt;DIV align=center&gt;JW2£­126£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;40/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;DIV&gt;&lt;BR&gt;JW2-252&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated short-time&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA/S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Rated peak value&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;One minute power frequency&lt;/DIV&gt;
&lt;DIV align=center&gt;Withstand voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;lightning surge&lt;/DIV&gt;
&lt;DIV align=center&gt;pressure resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;DIV align=center&gt;JW2£­252£¨W£©/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;two hundred and fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;40/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;one thousand and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]DJN-12/630 Grounding switch </title>
           <link>http://www.91way.com/info_en/1630.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:54</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=207&gt;
&lt;DIV align=center&gt;content&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;630A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=162&gt;
&lt;DIV align=center&gt;1250A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Isolation switch and grounding switch operating force distance&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¼200N.m&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¼200N.m&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Interphase center distance&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;165&#177;2mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;210&#177;2mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Interphase and relative ground&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¾125mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¾125mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Isolation switch opening distance&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¾150mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¾150mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;main circuit resistance&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¼70u&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;£¼40u&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DJN-12/630 grounding switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN1-12(C) series indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/392.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:52</pubDate>
           <comments></comments>
           <description>The JN1-12 (C) series indoor AC high voltage grounding switch is a single pole grounding switch used in circuit networks with rated voltage of 12kV and below AC 50Hz. It is a dedicated grounding switch used in conjunction with the GN19-12 (C) column high voltage switch for safe grounding during power outage maintenance.&lt;BR&gt;&lt;BR&gt;Characteristics of JN1-12 (C) Indoor AC High Voltage Grounding Switch:&lt;BR&gt;Single pole grounding switch, simple structure, easy and reliable operation, economical and practical. It is a dedicated grounding switch used in conjunction with the GN19-12 (C) series high-voltage isolation switch, serving as a safe grounding during power outage maintenance.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-12/40 series indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/1625.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:45</pubDate>
           <comments></comments>
           <description>The JN15-12/40 series indoor high-voltage grounding switch is designed and developed based on the ES1 type grounding switch. The structural form is assembled, and its performance meets the requirements of GB1985-89 &quot;AC High Voltage Isolation Switches and Grounding Switches&quot; and IEC129. It is suitable for indoor 3-12 kV three-phase AC 50 (60) HZ power systems and has a certain closing ability to protect other electrical equipment inside the switchgear from damage. It can be used in conjunction with various high-voltage switchgear as grounding protection during maintenance of high-voltage electrical equipment.&lt;BR&gt;&lt;BR&gt;JN15-12/40 series indoor high-voltage grounding switch model and its meaning:&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006112492329772.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 285px; HEIGHT: 227px&quot; border=0 hspace=0 alt=&quot;JN15-12/40 series indoor high-voltage grounding switch model description&quot; src=&quot;/uploadfiles/200611/2006112492329772.jpg&quot; width=285 height=227&gt;&lt;/A&gt;&lt;BR&gt;&#183;Environmental conditions for use:&lt;BR&gt;1. Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ.&lt;BR&gt;2. Altitude: not exceeding 1000 meters.&lt;BR&gt;3. Humidity conditions: The average daily relative humidity should not exceed 95%, and the average monthly relative humidity should not exceed 90%.&lt;BR&gt;4. Earthquake intensity: not exceeding 8 degrees.&lt;BR&gt;5. There is no fire, explosion hazard, severe dust, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;Main technical parameters of JN15-12/40 series indoor high-voltage grounding switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV align=center&gt;project&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72 noWrap&gt;
&lt;DIV align=center&gt;unit&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=196 colSpan=2 noWrap&gt;
&lt;DIV align=center&gt;data&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;rated voltage&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;KV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;twelve&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;Rated short-time withstand current (thermal stability)&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;forty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;S&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;four&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;Rated short-circuit closing current&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;Rated peak withstand current (dynamic stability)&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;one hundred&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 noWrap&gt;
&lt;DIV&gt;Rated insulation level&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;Rated short-time power frequency withstand voltage&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 noWrap&gt;
&lt;DIV align=center&gt;KV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 noWrap&gt;
&lt;DIV align=center&gt;Relative and relative time&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;forty-two&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;Rated lightning impulse withstand voltage&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=center&gt;seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV&gt;mechanical life&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV align=center&gt;time&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 noWrap&gt;
&lt;DIV align=center&gt;two thousand&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&#183;JN15-12/40 series indoor high-voltage grounding switch appearance and installation dimensions:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006112492454437.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 665px; HEIGHT: 267px&quot; border=0 hspace=0 alt=&quot;JN15-12/40 series indoor high-voltage grounding switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200611/2006112492454437.jpg&quot; width=665 height=267&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&#183;Copper bar wiring terminal diagram: &#183; Installation hole size diagram:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006112492521494.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 663px; HEIGHT: 245px&quot; border=0 hspace=0 alt=&quot;JN15-12/40 series indoor high-voltage grounding switch terminals and copper bars&quot; src=&quot;/uploadfiles/200611/2006112492521494.jpg&quot; width=663 height=245&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;Product Model&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;E&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;F&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;G&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;H&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;D&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;C&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;JN15-12/40-210&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;six hundred and fifty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;five hundred and sixteen&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;JN15-12/40-220&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and twenty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;six hundred and seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;five hundred and thirty-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;JN15-12/40-230&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and thirty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;six hundred and ninety-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;five hundred and fifty-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;JN15-12/40-250&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;seven hundred and thirty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;five hundred and ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD noWrap&gt;
&lt;DIV&gt;JN15-12/40-275&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;two hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;eight hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;six hundred and forty-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD noWrap x:num=&quot;None&quot;&gt;
&lt;DIV align=right&gt;one hundred and sixteen&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&#183;Ordering Notice:&lt;BR&gt;When ordering a grounding switch, it is necessary to indicate the product model, distance, and whether a live display device (display model) is provided.&lt;BR&gt;2. Does the length of the soft connection need to be extended (conventional L=240).&lt;BR&gt;3. If the user has special requirements, please negotiate with our factory to resolve them.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]EK6-12 type indoor high-voltage grounding switch EK6-12/31.5£¬12/40£¬EK6-12/50</title>
           <link>http://www.91way.com/info_en/1624.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:37</pubDate>
           <comments></comments>
           <description>The EK6-12 series indoor high-voltage grounding switch is a domestically produced product that has been improved from the German CALOK.EMAG company's EK6 type grounding switch and has advanced domestic standards. Its performance meets the requirements of GB1985-89 &quot;AC High Voltage Isolation Switches and Grounding Switches&quot; and IEC129, and is suitable for use in indoor 3-12 kV three-phase AC 50HZ power systems. It can be used in conjunction with various high-voltage switchgear as grounding protection for high-voltage electrical equipment maintenance.&lt;BR&gt;&lt;BR&gt;EK6-12 indoor high-voltage grounding switch model and its meaning:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/200611249439349.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 290px; HEIGHT: 226px&quot; border=0 hspace=0 alt=&quot;EK6-12 Indoor High Voltage Grounding Switch Model Description&quot; src=&quot;/uploadfiles/200611/200611249439349.jpg&quot; width=290 height=226&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;1. Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ.&lt;BR&gt;2. Altitude: not exceeding 1000 meters.&lt;BR&gt;3. Humidity conditions: The average daily relative humidity should not exceed 95%, and the average monthly relative humidity should not exceed 90%.&lt;BR&gt;4. Earthquake intensity: not exceeding 8 degrees.&lt;BR&gt;5. There is no fire, explosion hazard, severe dust, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;Main technical parameters of EK6-12 indoor high-voltage grounding switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Project&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;unit&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;data&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;rated voltage&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;Rated short-time withstand current (thermal stability)&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;Rated short-circuit duration&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;Rated short-circuit closing current&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;eighty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;Rated peak withstand current (dynamic stability)&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;eighty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV&gt;Rated insulation level&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;Rated short-time power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Relative and relative time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-two&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Rated lightning impulse withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV&gt;mechanical life&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;time&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;JN15-12/31.5 series indoor high-voltage grounding switch appearance and installation dimensions:&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/200611249544197.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 667px; HEIGHT: 249px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of EK6-12 indoor high-voltage grounding switch&quot; src=&quot;/uploadfiles/200611/200611249544197.jpg&quot; width=524 height=249&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&#183;Copper bar wiring terminal diagram: &#183; Installation hole size diagram:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/2006112491056383.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 668px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;Installation Hole Diagram for EK6-12 Indoor High Voltage Grounding Switch&quot; src=&quot;/uploadfiles/200611/2006112491056383.jpg&quot; width=524 height=250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=128&gt;
&lt;DIV&gt;Product Model&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;E&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;F&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;G&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;H&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;D&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;EK6-12/31.5-150&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;one hundred and fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;one hundred and sixty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;five hundred and thirty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;three hundred and ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;EK6-12/31.5-210&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;six hundred and fifty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;five hundred and sixteen&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;EK6-12/31.5-230&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two hundred and thirty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;six hundred and ninety-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;five hundred and fifty-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;EK6-12/31.5-250&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two hundred and fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;one hundred and eighty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;seven hundred and thirty-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;five hundred and ninety-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;EK6-12/31.5-275&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two hundred and seventy-five&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;fifty&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;two hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;eight hundred and ten&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV&gt;six hundred and forty-six&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200808/200881982413278.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 591px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;EK6-12 indoor high-voltage grounding switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200808/200881982413278.jpg&quot; width=524 height=295&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Ordering Notice:&lt;BR&gt;When ordering this product, please indicate the product model, rated voltage, phase spacing, installation position, and whether the mechanism is operated on the right or left.&lt;BR&gt;If users have special requirements, they can negotiate and resolve them.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN2-40.5 type indoor high-voltage grounding switch </title>
           <link>http://www.91way.com/info_en/1481.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:28</pubDate>
           <comments></comments>
           <description>The JN2-40.5 indoor high-voltage grounding switch is an indoor high-voltage electrical appliance designed based on the grounding switch section of GB1985-89 &quot;AC High Voltage Isolation Switches and Grounding Switches&quot;, which is equivalent to IEC 129-84 &quot;Isolation Switches and Grounding Switches&quot; and IEC 694-84 &quot;Common Provisions for High Voltage Switchgear and Control Equipment&quot;. JN2-40.5 type grounding switch is suitable for power systems with three-phase AC 50Hz of 35KV and below, and has a voltage monitoring device. Its structure is simple and reliable, with low operating force and easy installation and debugging. It is usually used in JYN1-40.5 and GFC-40.5 switchgear, and can also be used separately.&lt;BR&gt;&lt;BR&gt;&#183;Environmental conditions for use&lt;BR&gt;1. Surrounding air temperature: upper limit+40 ¡æ, lower limit 10 ¡æ in general areas, daily temperature difference 15 ¡æ;&lt;BR&gt;2. The altitude is 1000m and below.&lt;BR&gt;3. Relative humidity: Monthly average not exceeding 90%, daily average not exceeding 95%.&lt;BR&gt;4. Seismic intensity: not exceeding 8 degrees;&lt;BR&gt;5. Environmental conditions: A place without fire, explosion hazards, severe dust, chemical corrosion, and severe vibration, with a pollution level of II.&lt;BR&gt;&lt;BR&gt;&#183;JN2-40.5 indoor high-voltage grounding switch model and meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/2006111713226392.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 593px; HEIGHT: 181px&quot; border=0 hspace=0 alt=&quot;JN2-40.5 Indoor High Voltage Grounding Switch Model Description&quot; src=&quot;/uploadfiles/200611/2006111713226392.jpg&quot; width=593 height=181&gt;&lt;/A&gt;&lt;BR&gt;&#183;Main technical parameters of JN2-40.5 indoor high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40£®5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-time withstand current (thermal stability)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-time duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated peak withstand current (dynamic stability)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-circuit closing current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;spacing&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;14%&quot;&gt;
&lt;DIV align=left&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=left&gt;Main circuit 1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Lightning impulse withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;secondary circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Charged display device with partial discharge capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;pC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Û10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&#183;JN2-40.5 indoor high-voltage grounding switch appearance and installation dimension diagram:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/2006111713319797.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 700px&quot; border=0 hspace=0 alt=&quot;JN2-40.5 Indoor High Voltage Grounding Switch Appearance and Installation Dimensions&quot; src=&quot;/uploadfiles/200611/2006111713319797.jpg&quot; width=680 height=700&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;JN2-40.5 indoor high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN4-12(G) type indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/393.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:20</pubDate>
           <comments></comments>
           <description>JN4-12 (G) type indoor high-voltage grounding switch is the main component used for 12kV indoor AC metal armored movable metal enclosed switchgear and other high-voltage switchgear, and can also be used separately. Used for grounding protection in AC 50Hz power systems of 12kV and below. Capable of closing short-circuit current. Reasonable structure, small size, flexible operation, easy installation and adjustment.&lt;BR&gt;&lt;BR&gt;Product Features:&lt;BR&gt;Product design is scientific, innovative, unique, and reasonable; Advanced and reliable technical performance; Adopting the principle of shunt magnetic lock, pressure is automatically generated when powered on,&lt;BR&gt;Ensure good contact; No need for corner pressure springs, low operating force. It can be used in conjunction with various types and models of high-voltage cabinets, and can also be used as grounding protection during maintenance of high-voltage electrical equipment&lt;BR&gt;&lt;BR&gt;Main technical parameters of JN4-12G indoor AC high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=35 width=&quot;34%&quot; colSpan=2 align=center&gt;
&lt;P align=left&gt;Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;9%&quot; align=center&gt;
&lt;P align=left&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;54%&quot; align=center&gt;
&lt;P align=left&gt;Parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;
&lt;P align=left&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;
&lt;P align=left&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;
&lt;P align=left&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;
&lt;P align=left&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;Rated short-time duration&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;S&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;KA&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;Rated short-time closing current&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;KA&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=&quot;34%&quot; colSpan=2 align=left&gt;Center distance between poles&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;mm&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;210£¬230£¬250&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=63 rowSpan=2 width=&quot;15%&quot; align=left&gt;Rated insulation water syndrome&lt;/TD&gt;
&lt;TD height=26 width=&quot;18%&quot; align=left&gt;Power frequency withstand voltage (1min)&lt;/TD&gt;
&lt;TD height=26 width=&quot;9%&quot; align=center&gt;KV&lt;/TD&gt;
&lt;TD height=26 width=&quot;54%&quot; align=center&gt;Ground 42&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;18%&quot; align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=center&gt;KV&lt;/TD&gt;
&lt;TD width=&quot;54%&quot; align=center&gt;Jijian 75&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Exterior installation dimensions&lt;BR&gt;&lt;BR&gt;
&lt;TABLE id=table4 style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=35 width=&quot;31%&quot; align=center&gt;Product model and specifications&lt;/TD&gt;
&lt;TD height=35 width=&quot;22%&quot; align=center&gt;A&lt;/TD&gt;
&lt;TD height=35 width=&quot;23%&quot; align=center&gt;B&lt;/TD&gt;
&lt;TD height=35 width=&quot;23%&quot; align=center&gt;C&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot; align=center&gt;JN12-12/31.5-150&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=center&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;three hundred and ninety-six&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;five hundred and thirty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot; align=center&gt;JN12-12/31.5-165&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=center&gt;one hundred and sixty-five&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;four hundred and twenty-six&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;five hundred and sixty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot; align=center&gt;JN12-12/31.5-210&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=center&gt;two hundred and ten&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;five hundred and sixteen&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;six hundred and fifty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot; align=center&gt;JN12-12/31.5-230&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=center&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;five hundred and fifty-six&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;seven hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot; align=center&gt;JN12-12/31.5-250&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=center&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;five hundred and ninety-six&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;seven hundred and sixty&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/2008788457571.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 413px; WIDTH: 539px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JN4-12G Indoor AC High Voltage Grounding Switch Appearance and Installation Dimensions&quot; src=&quot;/uploadfiles/200807/2008788457571.jpg&quot; width=524 height=413&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JN4-12G Indoor AC High Voltage Grounding Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN22-40.5/31.5 type grounding switch </title>
           <link>http://www.91way.com/info_en/1233.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:19</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JN22-40.5/31.5 indoor high-voltage grounding switch (hereinafter referred to as grounding switch) is an advanced level product with high technical parameter performance developed by Xi'an High Voltage Apparatus Research Institute. After comprehensive assessment, its performance meets the requirements of the national standard GB1985 &quot;AC High Voltage Isolating Switches and Grounding Switches&quot;, suitable for 40.5KV, AC 50Hz power systems, and can be used in conjunction with KYN61-41.5 and other types of high-voltage switchgear. It can also be used for grounding protection during high-voltage electrical commissioning and maintenance.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;project&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Center distance between poles&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;350; four hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Rated insulation level&lt;/TD&gt;
&lt;TD&gt;1-minute power frequency withstand voltage&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Extreme to ground and between poles&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/20061114173723953.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 352px&quot; border=0 hspace=0 alt=&quot;JN22-40.5/31.5 type grounding switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200611/20061114173723953.jpg&quot; width=550 height=352&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JN22-40.5/31.5 type grounding switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-10/31.5 (split type) grounding switch </title>
           <link>http://www.91way.com/info_en/1232.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:11</pubDate>
           <comments></comments>
           <description>JN15-10/31.5 (split type) grounding switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN12-35/25 type grounding switch </title>
           <link>http://www.91way.com/info_en/1231.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:20:02</pubDate>
           <comments></comments>
           <description>JN12-35/25 type grounding switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN15-12 series indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/391.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:19:35</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;JN15-12/T31.5-80 indoor AC high-voltage grounding switch is a product with international advanced level. Its performance meets the requirements of GB1985-1989 &quot;AC High Voltage Disconnectors and Grounding Switches&quot; and IEC129, and is suitable for use in power systems with AC 50Hz of 12kV and below. It can be used in conjunction with various types of high-voltage switchgear and can also be used as grounding protection for high-voltage electrical equipment maintenance. This type of switch can be used for selecting live display devices.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008527125014656.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 285px; HEIGHT: 181px&quot; border=0 hspace=0 alt=&quot;JN15-12, 40.5 Indoor AC High Voltage Grounding Switch Model Description&quot; src=&quot;/uploadfiles/200805/2008527125014656.jpg&quot; width=285 height=181&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Thermal stability current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD span=&quot;2&quot;&gt;
&lt;DIV align=center&gt;Thermal stability current time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Short circuit closing current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;65/80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Dynamic stable current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;28%&quot;&gt;
&lt;DIV align=center&gt;Extreme to ground and between poles&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;forty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Lightning impulse withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;Main technical parameters of JN15-12 series indoor AC high voltage grounding switch:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008527125037563.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 567px; HEIGHT: 153px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JN15-12 series indoor AC high voltage grounding switch&quot; src=&quot;/uploadfiles/200805/2008527125037563.jpg&quot; width=567 height=153&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852712510193.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 534px; HEIGHT: 274px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JN15-12 series indoor AC high voltage grounding switch&quot; src=&quot;/uploadfiles/200805/200852712510193.jpg&quot; width=534 height=274&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008527125119222.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 381px; HEIGHT: 314px&quot; border=0 hspace=0 alt=&quot;JN15-12 series indoor AC high voltage grounding switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008527125119222.jpg&quot; width=381 height=314&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JN15-12 series indoor AC high voltage grounding switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[High voltage grounding switch]JN3-12 shunt magnetic lock indoor AC high voltage grounding switch </title>
           <link>http://www.91way.com/info_en/390.html</link>
           <author></author>
           <guid></guid>
           <category>High voltage grounding switch</category>
           <pubDate>2026-6-20 10:19:26</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;The JN3-12 series shunt magnetic lock indoor high-voltage grounding switch is suitable for 12kV and AC 50Hz power systems, and can be used in conjunction with various types of high-voltage switchgear. It can also be used as grounding protection during maintenance of high-voltage electrical equipment. &amp;nbsp;&lt;BR&gt;Product features: 1. Scientific, innovative, unique, and reasonable product design; &amp;nbsp;&lt;BR&gt;2. Advanced and reliable technical performance; &amp;nbsp;&lt;BR&gt;3. Adopting the principle of shunt magnetic lock, pressure is automatically generated when powered on to ensure good contact; &amp;nbsp;&lt;BR&gt;4. No need to touch the pressure spring, low operating force. &amp;nbsp;&lt;BR&gt;5. It can be used in conjunction with various types of high-voltage switchgear and can also serve as grounding protection for high-voltage electrical equipment maintenance.&lt;BR&gt;&lt;BR&gt;Main technical parameters of JN3-12 shunt magnetic lock indoor AC high-voltage grounding switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=41 width=&quot;47%&quot; colSpan=2 align=middle&gt;Name&lt;/TD&gt;
&lt;TD height=41 width=41 align=middle&gt;Unit&lt;/TD&gt;
&lt;TD height=41 width=&quot;43%&quot; align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot; colSpan=2 align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;KV&lt;/TD&gt;
&lt;TD width=&quot;43%&quot; align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot; colSpan=2 align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;KA&lt;/TD&gt;
&lt;TD width=&quot;43%&quot; align=middle&gt;16,20,25,31.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot; colSpan=2 align=left&gt;Rated short-time duration&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;S&lt;/TD&gt;
&lt;TD width=208 align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot; colSpan=2 align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;KA&lt;/TD&gt;
&lt;TD width=208 align=middle&gt;40,50,63,80&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=27 width=&quot;47%&quot; colSpan=2 align=left&gt;Center distance between poles&lt;/TD&gt;
&lt;TD height=27 width=41 align=middle&gt;mm&lt;/TD&gt;
&lt;TD height=27 width=208 align=middle&gt;210,230,250,275&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=73 rowSpan=2 width=89 align=middle&gt;Rated insulation level&lt;/TD&gt;
&lt;TD height=38 width=122 align=middle&gt;Power frequency withstand voltage (1min)&lt;/TD&gt;
&lt;TD height=38 width=41 align=middle&gt;KV&lt;/TD&gt;
&lt;TD height=38 width=&quot;43%&quot; align=middle&gt;To ground 42, between poles 75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=122 align=middle&gt;Lightning impulse withstand voltage (peak value)&lt;/TD&gt;
&lt;TD width=41 align=middle&gt;KV&lt;/TD&gt;
&lt;TD width=&quot;43%&quot; align=middle&gt;To ground 42, between poles 75&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; id=table4 border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;Product model and specifications&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;A&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;B&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;C&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;D&lt;/TD&gt;
&lt;TD width=90 align=middle&gt;B&lt;/TD&gt;
&lt;TD width=90 align=middle&gt;C&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/20-210&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and ten&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and one&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and sixty-three&lt;/TD&gt;
&lt;TD height=96 rowSpan=4 width=90 align=middle&gt;Figure 3&lt;/TD&gt;
&lt;TD height=195 rowSpan=8 width=90 align=middle&gt;Figure 5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/20-230&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and forty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and one&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/20-250&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and eighty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and one&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/20-275&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and seventy-five&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;seven hundred and thirty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and one&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/31.5£¨25£©-210&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and ten&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and five&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and seventy&lt;/TD&gt;
&lt;TD height=99 rowSpan=4 width=90 align=middle&gt;Figure 4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/31.5£¨25£©-230&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and forty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and eight&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and seventy&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/31.5£¨25£©-250&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;six hundred and eighty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and eight&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and seventy&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=180 align=middle&gt;JN3-12/31.5£¨25£©-275&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;two hundred and seventy-five&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;seven hundred and thirty-four&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and eight&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;three hundred and seventy&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;JN3-12 shunt magnetic lock indoor AC high voltage grounding switch, external installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200807/200878829525.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 715px&quot; border=0 hspace=0 alt=&quot;JN3-12 shunt magnetic lock indoor AC high voltage grounding switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200807/200878829525.jpg&quot; width=550 height=715&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JN3-12 shunt magnetic lock indoor AC high voltage grounding switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>