<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - frequency meter</title>
       <link>http://www.91way.com</link>
       <description>frequency meter</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:15:24</pubDate>
       <item>
           <title>[frequency meter]D3-Hz series 0.2 level frequency meter </title>
           <link>http://www.91way.com/info_en/8033.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:32:23</pubDate>
           <comments></comments>
           <description>D3 Hz series 0.2 level frequency meter, electric series, AC/DC meter specifications and main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=11 width=69&gt;Frequency table level 0.2&lt;/TD&gt;
&lt;TD rowSpan=11&gt;D3Hz-1&lt;/TD&gt;
&lt;TD colSpan=2&gt;rated voltage&lt;/TD&gt;
&lt;TD colSpan=2&gt;measurement range&lt;/TD&gt;
&lt;TD rowSpan=11 colSpan=2&gt;265&#215;195&#215;165&lt;/TD&gt;
&lt;TD rowSpan=11 width=138 colSpan=2&gt;Suitable for measuring frequency in AC circuits Listed as a special specification&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=10 colSpan=2&gt;36-110-220V (special specification) or 110-220-380V&lt;/TD&gt;
&lt;TD colSpan=2&gt;45-65Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;90-110 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;135-165 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;180-220 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;350-450 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;450-550 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;700-900 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;900-1100 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;1800-2200 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;2250-2750 Hz&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;D3 Hz series 0.2 level frequency meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[frequency meter]F96D-2HzB Dual needle frequency meter </title>
           <link>http://www.91way.com/info_en/23630.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:44</pubDate>
           <comments></comments>
           <description>F96D-2HzB Dual Pin Frequency Meter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]AS9001 type error code tester </title>
           <link>http://www.91way.com/info_en/19947.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:36</pubDate>
           <comments></comments>
           <description>AS9001 type error code tester&lt;BR&gt;&lt;BR&gt;1﹜ Usage characteristics:&lt;BR&gt;1. Easy to operate: using a Chinese character LCD display screen, with menu prompts for various operations, making it convenient to use;&lt;BR&gt;2. Having memory function: After the user correctly sets the parameters, they can continue to use them in future testing processes.&lt;BR&gt;3. Provide multiple testing interfaces, such as TTL, RS232 interface, RS422 interface, etc.&lt;BR&gt;4. Wide adaptability and high testing speed: the maximum testing speed is not less than 2.048 Mbps.&lt;BR&gt;5. Capable of testing various error damage performance indicators of the channel;&lt;BR&gt;6. Synchronous display of test results: AS9001 displays all measurement indicators simultaneously during the measurement process.&lt;BR&gt;7. Parameters can be set according to user needs, such as the selection of test frame length, test interval, and so on.&lt;BR&gt;8. High reliability and expandable functionality: The device adopts FPGA+microprocessor design, adding new functions according to users' new requirements.&lt;BR&gt;&lt;BR&gt;2﹜ Technical requirements for AS9001 bit error tester:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;According to the speed&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;
&lt;P&gt;Burst mode: greater than 2.048Mbps&lt;/P&gt;
&lt;P&gt;Continuous mode: greater than 2.048Mbps&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2 noWrap&gt;interface method&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;
&lt;P&gt;Interface 1: Compliant with TTL interface electrical characteristics&lt;/P&gt;
&lt;P&gt;Interface 2: Compliant with RS232 interface electrical characteristics&lt;/P&gt;
&lt;P&gt;Interface 3: Compliant with RS422 interface electrical characteristics&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;Test code type&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;Six code types: 1 code, 0/1 code, 223-1 PN sequence, 229-1 PN sequence, 215-1 PN sequence&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;frame length&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;128/256/512/1024/2048/4096 bit with six selectable lengths&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;Frame interval (for burst mode)&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;128/256/512/1024/2048/4096 bit with six selectable lengths&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;Equipped with internal and external clock selection&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;Internal clock rate selection: Six clock rates of 2.4/4.8/9.6/16/32/64 kbps&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132 colSpan=2&gt;Measurable channel error damage index&lt;/TD&gt;
&lt;TD width=550 colSpan=2&gt;
&lt;P&gt;Burst mode: average bit error rate, frame error rate, frame loss rate;&lt;/P&gt;
&lt;P&gt;Continuous mode: average bit error rate, second error rate (bit error rate, frame error rate), average cycle time, average slide time&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[frequency meter]AS3345 digital frequency meter </title>
           <link>http://www.91way.com/info_en/19946.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:27</pubDate>
           <comments></comments>
           <description>AS3345 Digital Frequency Meter:&lt;BR&gt;&lt;BR&gt;8-digit display, 10Hz~100MHz&lt;BR&gt;Sensitivity: 30mV&lt;BR&gt;Accuracy: 4 &#215; 10-6&lt;BR&gt;Daily stability: 5 &#215; 10-6&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]AS3374 digital frequency meter </title>
           <link>http://www.91way.com/info_en/19945.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:19</pubDate>
           <comments></comments>
           <description>AS3374 Digital Frequency Meter:&lt;BR&gt;&lt;BR&gt;8-digit display, frequency measurement: 10Hz~2GHz&lt;BR&gt;Sensitivity: 30mV&lt;BR&gt;Accuracy: 4 &#215; 10-6&lt;BR&gt;Daily stability: 5 &#215; 10-6&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]PP17 portable high-precision frequency meter </title>
           <link>http://www.91way.com/info_en/19402.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:09</pubDate>
           <comments></comments>
           <description>The PP17P portable high-precision frequency meter is a series of products of the power frequency electrical parameter tester (standard meter). It uses a high-speed and high-precision A/D converter as the core, and utilizes multiple microprocessors and large-scale programmable logic integrated circuits to synchronously sample voltage, current, and period at high speed. The effective values of voltage and current are calculated mathematically. This table is also based on internal precision standards and regularly self calibrated. At the same time, the calibration of the overall instrument adopts digital correction without the need for potentiometers, thereby reducing the uncertainty of the instrument and achieving long-term high-precision measurement of the instrument.&lt;BR&gt;The PP17 portable high-precision frequency meter adopts an imported aluminum chassis and vacuum fluorescent plasma display, which has a beautiful appearance and clear display. It is currently one of the highest performance instruments for measuring power frequency electrical parameters in China. It can be widely used as a frequency measurement standard meter or on-site testing equipment in metrology institutes, industrial and mining enterprises, metrology departments of power systems, laboratories, etc.&lt;BR&gt;&lt;BR&gt;Main technical performance indicators&lt;BR&gt;Basic requirements: This instrument complies with the provisions of Group I instruments in the national standard GB8587-86 &quot;General Principles for Environmental Testing of Measuring Instruments&quot;: the rated working temperature is 18 ⊥~22 ⊥, the humidity is ≒ 86% RH, and it is allowed to work at 5 ⊥~45 ⊥.&lt;BR&gt;Measurement range: Type A 10Hz~10KHz, Type B 10Hz~1MHz, Type C 0.005Hz~1000Hz&lt;BR&gt;Input voltage: 0.1V~400V Input impedance: R ≡ 2M 次 Input load: 0.1VA&lt;BR&gt;Temperature coefficient: better than 10PPM/⊥ within 5 ⊥~45 ⊥ Accuracy: 0.005%&lt;BR&gt;&lt;BR&gt;other&lt;BR&gt;Power supply: Rated voltage: 220V &#177; 5%&lt;BR&gt;Rated frequency: 50HZ &#177; 5%, approximately 30W&lt;BR&gt;Preheating time: Accurate measurement takes 30 minutes under rated working environment&lt;BR&gt;Dimensions: 285mm &#215; 250mm &#215; 110mm (L &#215; B &#215; H) Weight: Approximately 3.5Kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]ZW5405 Frequency Table </title>
           <link>http://www.91way.com/info_en/15794.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:22:01</pubDate>
           <comments></comments>
           <description>ZW5405 Frequency Table&lt;BR&gt;&lt;BR&gt;Measurement item: F (45-65) Hz&lt;BR&gt;Input: AC (50-500) V&lt;BR&gt;Measurement Error Accuracy: &#177; 0.05Hz&lt;BR&gt;Display: 4 digits, 0.8 &quot;LED&lt;BR&gt;Power Supply: AC220V &#177; 10%/AC100V &#177; 10% (optional)&lt;BR&gt;Instrument dimensions: 80 (H) &#215; 160 (W) &#215; 124 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 150 &#215; 75mm&lt;BR&gt;Instrument weight NetWeight: ＞ 600g&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]ZW1620F Intermediate Frequency Table </title>
           <link>http://www.91way.com/info_en/15738.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:52</pubDate>
           <comments></comments>
           <description>ZW1620F intermediate frequency meter&lt;BR&gt;&lt;BR&gt;Measurement item: F (45Hz-1kHz)&lt;BR&gt;Accuracy level: Level 0.5 (45Hz-65Hz)/Level 1.0 (66Hz-1kHz)&lt;BR&gt;Frequency response BandWidth: (45-1000) Hz&lt;BR&gt;Power Supply: AC 85-265V 50/60Hz&lt;BR&gt;Instrument dimensions: 48 (H) &#215; 96 (W) &#215; 105 (D) mm&lt;BR&gt;Opening size Panel Cut Out: 44 &#215; 91 (mmxmm)&lt;BR&gt;Instrument weight NetWeight: ＞ 340g&lt;BR&gt;Display: 4 digits, 0.5 &quot;LED&lt;BR&gt;RS485 option (ModBus protocol)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]PC91 series panel digital ohmmeter </title>
           <link>http://www.91way.com/info_en/13848.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:43</pubDate>
           <comments></comments>
           <description>The PC91 series panel type digital ohmmeter is a small and popular instrument for 4 and a half bit CMOS large-scale integrated circuits. Its measurement results are displayed using five digit LEDs, and low resistance measurement adopts a four terminal measurement method. This meter has the characteristics of small size, low power consumption, high sensitivity, good reliability, excellent performance, strong adaptability, and easy use. It is a supporting instrument for various measuring instruments and consoles. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical data&lt;BR&gt;&lt;BR&gt;Usage conditions&lt;BR&gt;Environmental temperature: 0-+40 ⊥&lt;BR&gt;Relative humidity of the environment: below 80%&lt;BR&gt;Power supply: 220V &#177; 22V, 50 &#177; 1.5Hz (including PC91/51-58A: DC 24V &#177; 3.0V or 9.0V &#177; 0.5V)&lt;BR&gt;&lt;BR&gt;Specifications, display values, and basic errors: Under reference conditions, the basic errors of the product should comply with the following table.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;test current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=143&gt;
&lt;P align=center&gt;basic error&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-19.999次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;1m次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;10mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=143&gt;
&lt;P align=center&gt;&#177; (0.05% reading+3 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-199.99次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;10m次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;1mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=143&gt;
&lt;P align=center&gt;&#177; (0.05% reading+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-1.9999k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;100m次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;0.1mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-19.999k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;1次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;10米A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-199.99k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;10次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;1米A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=143&gt;
&lt;P align=center&gt;&#177; (0.06% reading+3 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/51&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-19.999次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;1m次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;10mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=143&gt;
&lt;P align=center&gt;&#177; (0.05% reading+2 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=70&gt;
&lt;P align=center&gt;PC91/58A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0-100.0M次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;100k次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=68&gt;
&lt;P align=center&gt;10nA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=143&gt;
&lt;P align=center&gt;&#177; (3% reading+5 words)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Weight: 0.6kg&lt;BR&gt;Dimensions: 48 &amp;acute; 110 &amp;acute; 112mm&lt;BR&gt;Hole size: 44'95mm&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[frequency meter]PP32 Type Panel Digital Frequency Meter </title>
           <link>http://www.91way.com/info_en/13847.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:34</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The PP32 panel digital frequency meter is a small and popular instrument that uses CMOS large-scale integrated circuits, and its measurement results are displayed using an eight digit LED. It can be used in conjunction with various sensors or converters to conveniently achieve digital measurement of various electrical and non electrical quantities, making it an ideal matching instrument for various measuring instruments and consoles. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;technical indicators&lt;BR&gt;&lt;BR&gt;Usage conditions&lt;BR&gt;Environmental temperature: 0-+40 ⊥; &amp;nbsp;&lt;BR&gt;Relative humidity of the environment: below 80%; &amp;nbsp;&lt;BR&gt;Power supply: 220 &#177; 22V power frequency 50Hz;&lt;BR&gt;&lt;BR&gt;Measurement frequency&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;specification&lt;/P&gt;
&lt;P&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;PP32/1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;PP32/2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;PP32/3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=3&gt;
&lt;P&gt;10Hz〞10MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Measure amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=3&gt;
&lt;P&gt;100mV-20V (effective value)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Input waveform&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=3&gt;
&lt;P&gt;Sine wave, triangular wave, square wave&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;accuracy&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=3&gt;
&lt;P&gt;&#177; 0.005% &#177; 1/ft (f: measured frequency meter; t: Gate time)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=3&gt;
&lt;P&gt;Greater than 500k 次/less than 45pf&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;gate time &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;0.1s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;1s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;10s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Display digits&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;7 digits&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;8 digits&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;8 digits&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;resolution&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;10Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;1Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;0.1Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Weight: less than 0.6kg&lt;BR&gt;&lt;BR&gt;Dimensions: 48 &#215; 110 &#215; 112mm&lt;BR&gt;&lt;BR&gt;Hole size: 44 &#215; 95mm&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[frequency meter]PP18/1 type digital power frequency meter </title>
           <link>http://www.91way.com/info_en/13846.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:26</pubDate>
           <comments></comments>
           <description>The PP18/1 digital power frequency meter is a high-precision panel instrument that measures 50Hz power frequency with a resolution of up to 0.01Hz. The table adopts large-scale frequency measurement integrated circuits and frequency synthesis technology, which endows the instrument with excellent performance of high precision, high stability, and high reliability. The instrument adopts a 4-digit LED digital display for reading, which is soft and eye-catching. This product adopts a full plastic structure with a small and lightweight design, making it a measuring tool for power systems and scientific research institutions.&lt;BR&gt;&lt;BR&gt;Technical data of PP18/1 digital frequency meter&lt;BR&gt;Terms of Use&lt;BR&gt;Environmental temperature: 5-+40 ⊥&lt;BR&gt;Relative humidity of the environment: 20% -80% (no condensation)&lt;BR&gt;Power supply: 220V &#177; 20V 50 &#177; 1.5Hz&lt;BR&gt;Should not be subjected to severe vibrations and mechanical impacts&lt;BR&gt;The air should not contain dust and impurities sufficient to corrode the instrument&lt;BR&gt;Should not be interfered by strong electromagnetic fields&lt;BR&gt;&lt;BR&gt;Specifications and input characteristics&lt;BR&gt;Measurement range: 40.00-70.00Hz&lt;BR&gt;Resolution: 0.01Hz&lt;BR&gt;Power frequency measurement: Power frequency and sine wave Vp-p ≒ 550V, there should be no strong electromagnetic field interference&lt;BR&gt;Conversion rate: 1 time/second&lt;BR&gt;Basic error: 0.03% reading &#177; 2 words&lt;BR&gt;&lt;BR&gt;Dimensions: 48 &#215; 110 &#215; 110mm&lt;BR&gt;Hole size: 44 &#215; 95mm&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]HB404F Intelligent power frequency meter </title>
           <link>http://www.91way.com/info_en/9031.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:18</pubDate>
           <comments></comments>
           <description>&lt;P&gt;HB404F intelligent power frequency meter&lt;BR&gt;&lt;BR&gt;1﹜ Characteristics&lt;BR&gt;Measure the frequency of industrial electricity consumption&lt;BR&gt;Input voltage: AC: 0-500V&lt;BR&gt;Response frequency: 20.00-99.99Hz&lt;BR&gt;Relay alarm output, alarm range can be set&lt;BR&gt;Simulate current transmission output, with adjustable transmission output range&lt;BR&gt;&lt;BR&gt;2﹜ Technical parameters of HB404F intelligent power frequency meter&lt;BR&gt;1. Working power supply: AC/DC85-260V (other power supplies can be customized)&lt;BR&gt;2. Frequency measurement range: 20.00-99.99Hz&lt;BR&gt;3. Measurement accuracy: Level 0.5&lt;BR&gt;4. Contact capacity: AC250V/3A&lt;BR&gt;5. Transmission output: 4-20mA, 0-20mA&lt;BR&gt;6. Transmission accuracy: 1% FS&lt;BR&gt;7. Dimensions: 96 &#215; 48 &#215; 82mm&lt;BR&gt;8. Hole size: 92 &#215; 44 mm&lt;BR&gt;9. Operating environment: 0-50 ⊥; ≒85ㄔRH&lt;BR&gt;&lt;BR&gt;3﹜ Model Description&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009119224647967.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;HB404F Intelligent Frequency Meter Model Description&quot; src=&quot;/upload2009/200911/2009119224647967.jpg&quot; width=680 height=270&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;HB404F intelligent power frequency meter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[frequency meter]GFC-8010H frequency meter </title>
           <link>http://www.91way.com/info_en/8766.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:09</pubDate>
           <comments></comments>
           <description>Detailed information of GFC-8010H frequency meter:&lt;BR&gt;&lt;BR&gt;Product model: gfc-8010h&lt;BR&gt;Product Introduction:&lt;BR&gt;ㄝgfc-8010h (120mhz)&lt;BR&gt;Provide frequency and cycle measurements&lt;BR&gt;Frequency range: 1hz~120mhz&lt;BR&gt;8-digit 0.3 &quot;LED display&lt;BR&gt;. over flow indicator light&lt;BR&gt;High sensitivity:&amp;lt;15mvrms&lt;BR&gt;High stability time base: 5ppm&lt;BR&gt;Equipped with low-pass filter function&lt;BR&gt;display&lt;BR&gt;8-bit with hz, khz, mhz, ghz, s, ms, 米 s, ns, and overflow&lt;BR&gt;gate time&lt;BR&gt;0.1s, 1s, 10s switch se-lectable&lt;BR&gt;accuracy&lt;BR&gt;+(1 digit+time reference accuracy)&lt;BR&gt;input&lt;BR&gt;Sensitivity of 10hz~60mhz&amp;lt;20mvrms;&lt;BR&gt;60mhz ~ 100mhz &amp;lt; 30mvrms˙&lt;BR&gt;100mhz ~ 120mhz &amp;lt; 40mvrms&lt;BR&gt;Impedance 1m 肋//35pf&lt;BR&gt;Coupling AC coupling&lt;BR&gt;Maximum input voltage 150vrms&lt;BR&gt;&lt;BR&gt;time base&lt;BR&gt;Oscillation frequency 10mhz&lt;BR&gt;&lt;BR&gt;Temperature stability 25 &#176; C &#177; 5 &#176; C: &#177; 5 ppm&lt;BR&gt;Resolution using AC 100v/120v/220V/230v &#177; 10%, 50/60hz power supply&lt;BR&gt;attachment&lt;BR&gt;Operation manual x 1,&lt;BR&gt;1 power cord,&lt;BR&gt;Test line gtl-101 &#215; 1&lt;BR&gt;Dimensions and Weight&lt;BR&gt;230 (width) x 95 (height) x 280 (length) mm,&lt;BR&gt;About 1.7 kilograms&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]VC3165 Intelligent Frequency Meter </title>
           <link>http://www.91way.com/info_en/8765.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:21:01</pubDate>
           <comments></comments>
           <description>Detailed information on VC3165 intelligent frequency meter:&lt;BR&gt;&lt;BR&gt;8-bit LED display, working status and unit display&lt;BR&gt;Gear selection, stable performance, high reliability&lt;BR&gt;The gate time can be continuously adjusted within a range of 100ms-10s&lt;BR&gt;Frequency measurement: 0.01Hz~2.4GHz&lt;BR&gt;Cycle measurement: 0.5us-10s&lt;BR&gt;Input sensitivity: 100mVrms&lt;BR&gt;Power supply: 110/220V &#177; 10%&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]PM6669 High precision frequency meter </title>
           <link>http://www.91way.com/info_en/8764.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:52</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Detailed information on PM6669 high-precision frequency meter:&lt;BR&gt;&lt;BR&gt;A frequency counter that completely breaks down the barrier of cost-effectiveness&lt;BR&gt;PM 6669 is a very economical and easy-to-use frequency counter that fully meets your demanding requirements for high-precision measurement, reliability, and durability. &amp;nbsp;&lt;BR&gt;The multifunctional PM 6669 provides frequency, cycle, summation count, ratio, pulse width, and frequency offset measurement functions. &amp;nbsp;&lt;BR&gt;The optional components for enhancing functionality include a 1.3 GHz input, battery pack, high stability MTCXO time base oscillator, and IEEE-488 bus interface.&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;measurement function&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Measurement Mode&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Frequency A, Frequency B, Period A, RPM A, Totalize A. Frequency A/Ao, Frequency A-Ao, Pulse Width A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Frequency A or B (optional)&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Range:&lt;/TD&gt;
&lt;TD&gt;Frequency A: 0.1 Hz... 160 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Frequency B: 70 MHz... 1.3 GHz (Option PM 9608B)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;pattern&lt;/TD&gt;
&lt;TD&gt;Countdown frequency calculation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Displayed LSD:&lt;/TD&gt;
&lt;TD&gt;2.5 x 10-7 x frequency/measurement time&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Frequency A/Ao&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Measure frequency A. The measured frequency is divided by a constant Ao before display. The resolution of the displayed ratio is determined by the measurement of frequency A. When powered on, Ao is set to 1 (default value).&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Frequency A-Ao&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Measure frequency A. Subtract the value of constant Ao from the measured frequency before displaying. The resolution of the displayed differential is determined by the measurement of frequency A. When powered on, Ao is set to 0 (default value).&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;RPM A&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Measure frequency A. Multiply the measured frequency by 60 and display the result as revolutions per second (RPM) on the screen.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Range:&lt;/TD&gt;
&lt;TD&gt;6 RPM...720 x 106 RPM&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Cycle A&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Range:&lt;/TD&gt;
&lt;TD&gt;8 ns...2 x 108s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;pattern&lt;/TD&gt;
&lt;TD&gt;Single cycle measurement (SINGLE) or cycle average measurement (measurement time of 0.2, 1, or 10 seconds).&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Displayed LSD:&lt;/TD&gt;
&lt;TD&gt;Single cycle measurement:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;(Time&amp;lt;100s): 100ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;(Time&amp;gt;100s): 5 x cycles/109s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Cycle average measurement: 2.5 x 10-7 x cycles/measurement time&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Accumulate A&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;The calculation of the event is controlled by the START/STOP button. Accumulate the number of consecutive start stop cycles. The RESET button will turn off the gate signal and reset the frequency counter to zero.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Range:&lt;/TD&gt;
&lt;TD&gt;0... 1 x 1015 ㄛ There are units indicating k or M (thousands or trillions). If it exceeds the range, the result will be discarded.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Frequency range:&lt;/TD&gt;
&lt;TD&gt;Sine wave: 10 Hz... 16 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Pulse wave: 0 Hz... 16 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Pulse resolution: 80 ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Displayed LSD:&lt;/TD&gt;
&lt;TD&gt;1 count (count&amp;lt;109)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;5 x Count/109 (Count &amp;sup3; 109)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Width A&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Measure the forward pulse width. The measurement time option is invalid (usually SINGLE measurement).&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Range:&lt;/TD&gt;
&lt;TD&gt;100 ns...2 x 108s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Displayed LSD:&lt;/TD&gt;
&lt;TD&gt;(Time&amp;lt;100s): 100ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;(Time &amp;sup3; 100s): 5 x width/109s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;(Only when the duty cycle of the signal is 0.5, a trigger may occur at 50% of the amplitude)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;&lt;A name=spec1421&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;definition&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Displayed LSD&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE style=&quot;WIDTH: 550px&quot; border=0 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;LSD =&lt;/TD&gt;
&lt;TD&gt;The value of the least significant bit displayed. All calculated LSD (see measurement function section) should be rounded to the nearest decimal (e.g. 0.3 Hz rounded to 0.1 Hz, 5 Hz rounded to 10 Hz) and should not exceed 9 words.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;resolution&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Resolution=&lt;/TD&gt;
&lt;TD&gt;The minimum increment between two measurement results on the display screen, with an error of one word.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Frequency A, B, period:&lt;/TD&gt;
&lt;TD&gt;The resolution can be 1 LSD unit or 2 LSD units. If:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;If the LSD x measurement time/frequency or period is less than 10-7, the resolution is 2 LSD units (with a 30% probability)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Otherwise, the resolution is 1 LSD unit (with a 70% probability).&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Single cycle A and width A:&lt;/TD&gt;
&lt;TD&gt;The resolution is equal to 1 LSD unit.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Inaccuracy&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Inaccuracy,&lt;/TD&gt;
&lt;TD&gt;That is to say, the relative error depends on the following factors:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&#177; Resolution/frequency, period or width&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&#177; Relative triggering error&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&#177; relative time base error&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Relative triggering error&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Frequency A, Period A:&lt;/TD&gt;
&lt;TD&gt;&#177; Noise Voltage A (Vpp)/Signal Slope A (V/s) x Measurement Time&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Relative time base error&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Deviation of &#177; 10 MHz/10 MHz&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/A&gt;
&lt;P&gt;&lt;BR&gt;&lt;A name=spec1422&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;PM6669 high-precision frequency meter input technical specifications&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;Enter A&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Frequency range:&lt;/TD&gt;
&lt;TD&gt;10 Hz... 160 MHz (120 MHz value is 160 MHz, within a certain temperature range; Typical value is+23 &amp;ordm; C &#177; 5 &amp;ordm; C)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Sensitivity:&lt;/TD&gt;
&lt;TD&gt;Sine wave:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;10 mVrms, 10 Hz to 120 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;30 mV rms typical value, 120 to 160 MHz at room temperature&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Pulse: 30 mV rms, 0.1 Hz... 120 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Coupling:&lt;/TD&gt;
&lt;TD&gt;Communication coupling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Impedance:&lt;/TD&gt;
&lt;TD&gt;1 M次 // 30 pF&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Attenuation:&lt;/TD&gt;
&lt;TD&gt;Continuously adjustable within two ranges between x1 and x400&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;wave filter:&lt;/TD&gt;
&lt;TD&gt;A switchable 50 kHz low-pass noise filter with a suppression of 20 dB at 200 kHz.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum voltage:&lt;/TD&gt;
&lt;TD&gt;350V (DC+AC peak) between 0 and 440 Hz, drops to 11 Vrms at 1 MHz.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;trigger&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Trigger level:&lt;/TD&gt;
&lt;TD&gt;3 different trigger levels, adjustable duty cycle, and automatic:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Symmetric input signal can be selected with a duty cycle of 0.25... 0.75 for the input signal.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Positive pulse, used for input signals with a duty cycle&amp;lt;0.25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;Negative pulse, used for input signals with duty cycle&amp;gt;0.75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Automatic trigger level:&lt;/TD&gt;
&lt;TD&gt;The frequency counter will undergo testing and automatically select the optimal trigger level setting. The automatic mode requires repetitive signals with a repetition rate&amp;gt;100 Hz. In TOTALIZE-A measurement mode, the automatic function is not available.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Trigger slope (triggered only through GPIB):&lt;/TD&gt;
&lt;TD&gt;Positive or negative&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;RF input 1.3 GHz (option PM 9608B)&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;PM 6666&lt;/TD&gt;
&lt;TD&gt;Enter C&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;PM 6669&lt;/TD&gt;
&lt;TD&gt;Enter B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Frequency range:&lt;/TD&gt;
&lt;TD&gt;70 MHz to 1.3 GHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Coupling:&lt;/TD&gt;
&lt;TD&gt;Communication coupling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Working input voltage range:&lt;/TD&gt;
&lt;TD&gt;10 mV rms to 12 V rms, 70 MHz to 900 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;15 mV rms to 12 V rms, 900 MHz to 1.1 GHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;40 mV rms to 12 V rms, 1.1 to 1.3 GHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Amplitude modulation tolerance&lt;/TD&gt;
&lt;TD&gt;98%, the minimum signal must exceed the required minimum operating input voltage&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Impedance:&lt;/TD&gt;
&lt;TD&gt;50 次 nominal value, VSWR &amp;lt; 2:1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum voltage that will not cause damage:&lt;/TD&gt;
&lt;TD&gt;12 V rms, Provide overload protection through PIN diode&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=150&gt;External reference input D&lt;/TD&gt;
&lt;TD width=420&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;When an appropriate external reference signal is connected, the input is automatically monitored. The display screen will show that an external reference signal has been used.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Input frequency:&lt;/TD&gt;
&lt;TD&gt;10 MHz &#177; 0.1 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Coupling:&lt;/TD&gt;
&lt;TD&gt;Communication coupling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Sensitivity:&lt;/TD&gt;
&lt;TD&gt;500 mV rms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Input impedance:&lt;/TD&gt;
&lt;TD&gt;Approximately 300 次 at 10 MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum input voltage:&lt;/TD&gt;
&lt;TD&gt;15 V rms&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/A&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3381A digital frequency meter </title>
           <link>http://www.91way.com/info_en/8763.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:44</pubDate>
           <comments></comments>
           <description>Detailed information on DF3381A digital frequency meter:&lt;BR&gt;&lt;BR&gt;Using a microcontroller for measurement, data processing, and control.&lt;BR&gt;It has functions of frequency measurement, cycle measurement, and counting.&lt;BR&gt;8-bit precision display.&lt;BR&gt;The frequency stability is higher than that of a typical digital frequency meter.&lt;BR&gt;Equipped with an input attenuator.&lt;BR&gt;Equipped with a low-pass filter.&lt;BR&gt;There is a 10MHz time base output.&lt;BR&gt;The decimal point is automatically located and the unit indicator light is automatically displayed.&lt;BR&gt;There is an overflow indication beyond the measurement range.&lt;BR&gt;Multi level pre selection and maintenance during gate operation.&lt;BR&gt;&lt;BR&gt;Technical parameters of DF3381A digital frequency meter:&lt;BR&gt;&lt;BR&gt;A-channel frequency measurement range: 1Hz~100MHz&lt;BR&gt;B-channel frequency measurement range: 100MHz to 1.2GHz&lt;BR&gt;A-channel cycle measurement range: 1Hz-10MHz&lt;BR&gt;A-channel counting range: 108-1 (1Hz~10MHz)&lt;BR&gt;Frequency stability: 5 &#215; 10-6/day&lt;BR&gt;Maximum measurement sensitivity: better than 20mVrms&lt;BR&gt;Input impedance of channel A: 1M 次/35pF&lt;BR&gt;B-channel input impedance: 50 次&lt;BR&gt;Maximum safe input voltage: 250 (DC+ACpp)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3322 digital frequency meter </title>
           <link>http://www.91way.com/info_en/8762.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:36</pubDate>
           <comments></comments>
           <description>Detailed information of DF3322 digital frequency meter:&lt;BR&gt;&lt;BR&gt;Features:&lt;BR&gt;Eight and a half digit display.&lt;BR&gt;There are multiple measurement functions such as frequency, cycle, external control timing, manual control timing, and cumulative counting.&lt;BR&gt;The cycle measurement can be as low as 10 seconds.&lt;BR&gt;The timing measurement can be as low as 200000 seconds.&lt;BR&gt;Automatic decimal point positioning.&lt;BR&gt;The unit indicator light automatically displays.&lt;BR&gt;There is a standard frequency self-test function.&lt;BR&gt;Suitable for measuring various waveforms.&lt;BR&gt;&lt;BR&gt;Technical parameters of DF3322 digital frequency meter:&lt;BR&gt;&lt;BR&gt;Frequency measurement range: 1Hz~10MHz&lt;BR&gt;Periodic measurement range: 0.1 米 S to 10 seconds&lt;BR&gt;External control timing range: 10S to 2 &#215; 105S&lt;BR&gt;Manual timing range: up to 2 &#215; 105S&lt;BR&gt;Accumulated counting range: up to 2 &#215; 105-1 times&lt;BR&gt;Frequency stability: 1 &#215; 10-5/day&lt;BR&gt;Maximum sensitivity: 30mVrms&lt;BR&gt;Input impedance: 1M 次/25pF&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]GPS Reference Rubidium Atomic Frequency Standard </title>
           <link>http://www.91way.com/info_en/8761.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:28</pubDate>
           <comments></comments>
           <description>Detailed information on the GPS reference rubidium atomic frequency standard:&lt;BR&gt;&lt;BR&gt;Composed of a rubidium oscillator and a GPS receiver, the output frequency accuracy and drift of the rubidium oscillator are tested and calibrated using the reference second signal generated by GPS, resulting in higher average accuracy and better long-term stability of the frequency signal output by the oscillator. It can be used as a combination system for measuring and testing atomic frequency standards, high-precision frequency standards, and testing systems, with high cost-effectiveness.&lt;BR&gt;&lt;BR&gt;1. Output frequency: 10MHz, 5MHz, 1MHz&lt;BR&gt;2. Frequency standard characteristics&lt;BR&gt;Accuracy: ≒ 5E-12/24 hours after startup&lt;BR&gt;Drift: ≒ 5E-14/day (automatic mode, GPS taming)&lt;BR&gt;3. Time frequency testing&lt;BR&gt;&lt;BR&gt;The GPS reference rubidium atomic frequency standard can be used to test parameters such as frequency accuracy, frequency drift rate, frequency startup characteristics, and daily frequency fluctuations&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]F1000-C frequency meter </title>
           <link>http://www.91way.com/info_en/8760.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:19</pubDate>
           <comments></comments>
           <description>Introduction to F1000-C Frequency Meter&lt;BR&gt;&lt;BR&gt;Eight digit LED display&lt;BR&gt;Less switches and simple operation&lt;BR&gt;Fast and high-resolution&lt;BR&gt;&lt;BR&gt;Technical specifications of F1000-C frequency meter&lt;BR&gt;&lt;BR&gt;Frequency range: 10Hz~1000MHz&lt;BR&gt;Display: 8-bit LED&lt;BR&gt;Gate time: 0.01S/0.1S/1S (seconds)&lt;BR&gt;Accuracy: &#177; 1Hz &#177; 1 digit &#177; Time base accuracy&lt;BR&gt;Input sensitivity: 10Hz~10MHz: 20mV (channel 1); 10MHz~100MHz: 25mV (channel 1); 100MHz~1000MHz: 25mV (channel 2)&lt;BR&gt;Input impedance: 1M 次 channel 1, 50 次 channel 2&lt;BR&gt;Maximum input voltage: 250VRMS channel 1; 5VRMS channel 2&lt;BR&gt;Maximum aging rate: &#177; 5ppm per year&lt;BR&gt;Power requirement: AC 220V &#177; 10% (50/60Hz)&lt;BR&gt;Power consumption: approximately 5W&lt;BR&gt;Size: 210 x 230 x 76 (LxWxH) mm&lt;BR&gt;Weight: 1.8kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]GFC-8131H frequency meter </title>
           <link>http://www.91way.com/info_en/8759.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:11</pubDate>
           <comments></comments>
           <description>Detailed information of GFC-8131H frequency meter:&lt;BR&gt;&lt;BR&gt;Digital frequency counter, main specifications: 0.01Hz~1.3GHz&lt;BR&gt;Provide frequency and cycle measurements&lt;BR&gt;High resolution in both high and low frequencies&lt;BR&gt;Frequency range: 0.01Hz~1.3GHz&lt;BR&gt;High sensitivity: 10mVrms&lt;BR&gt;. 1Hz resolution: 100nHz&lt;BR&gt;Adjustable trigger level control&lt;BR&gt;Display lock function&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]VC2000 Intelligent Frequency Meter </title>
           <link>http://www.91way.com/info_en/8758.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:20:03</pubDate>
           <comments></comments>
           <description>VC2000 Intelligent Frequency Meter:&lt;BR&gt;&lt;BR&gt;8-bit LED display, working status memory&lt;BR&gt;The gear and gate time can be set according to the pulse count as needed&lt;BR&gt;Frequency measurement: 10Hz~2.4GHz&lt;BR&gt;Crystal oscillator measurement: 3.5MHz-16MHz&lt;BR&gt;Input sensitivity: 100mVrms&lt;BR&gt;Power supply: 110/220V &#177; 10%&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3370B digital frequency meter </title>
           <link>http://www.91way.com/info_en/8757.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:54</pubDate>
           <comments></comments>
           <description>The DF3370B digital frequency meter adopts large-scale frequency measurement integrated circuits and ultra high speed frequency division circuits.&lt;BR&gt;&lt;BR&gt;Equipped with equal precision measurement and easy touch button control.&lt;BR&gt;It has four measurement functions: frequency measurement, cycle measurement, cumulative counting, and self checking.&lt;BR&gt;There are two measurement channels, HF and UHF.&lt;BR&gt;Eight digit digital display.&lt;BR&gt;Automatic decimal point positioning.&lt;BR&gt;The unit indicator light automatically displays.&lt;BR&gt;Equipped with overflow indicator.&lt;BR&gt;There is a standard frequency self-test function.&lt;BR&gt;Equipped with a low-pass filter.&lt;BR&gt;Novel plastic casing, compact and beautiful in appearance.&lt;BR&gt;&lt;BR&gt;Main technical parameters of DF3370B digital frequency meter:&lt;BR&gt;HF frequency measurement range: 1Hz~100MHz&lt;BR&gt;UHF frequency measurement range: 100MHz~1GHz&lt;BR&gt;Periodic measurement range: 10Hz to 2.5MHz&lt;BR&gt;Counting measurement range: 108-1 (10Hz~10MHz)&lt;BR&gt;Frequency stability: 1 &#215; 10-5/day&lt;BR&gt;Maximum measurement sensitivity: better than 25mVrms&lt;BR&gt;Input impedance: 1M 次/35pF (HF channel) 50 次 (UHF channel)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3390B digital frequency meter </title>
           <link>http://www.91way.com/info_en/8756.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:46</pubDate>
           <comments></comments>
           <description>Features:&lt;BR&gt;Adopting large-scale frequency measurement integrated circuits and ultra high speed frequency division circuits.&lt;BR&gt;Equipped with equal precision measurement and easy touch button control.&lt;BR&gt;It has four measurement functions: frequency measurement, cycle measurement, cumulative counting, and self checking.&lt;BR&gt;There are two measurement channels, HF and UHF.&lt;BR&gt;Eight digit digital display.&lt;BR&gt;Automatic decimal point positioning.&lt;BR&gt;The unit indicator light automatically displays.&lt;BR&gt;Equipped with overflow indicator.&lt;BR&gt;There is a standard frequency self-test function.&lt;BR&gt;Equipped with a low-pass filter.&lt;BR&gt;Novel plastic casing, compact and beautiful in appearance.&lt;BR&gt;&lt;BR&gt;Main technical parameters of DF3390B digital frequency meter:&lt;BR&gt;&lt;BR&gt;HF frequency measurement range: 1Hz~100MHz&lt;BR&gt;UHF frequency measurement range: 100MHz~2.4GHz&lt;BR&gt;Periodic measurement range: 10Hz to 2.5MHz&lt;BR&gt;Counting measurement range: 108-1 (10Hz~10MHz)&lt;BR&gt;Frequency stability: 1 &#215; 10-5/day&lt;BR&gt;Maximum measurement sensitivity: better than 25mVrms&lt;BR&gt;Input impedance: 1M 次/35pF (HF channel) 50 次 (UHF channel)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3380A digital frequency meter </title>
           <link>http://www.91way.com/info_en/8755.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:38</pubDate>
           <comments></comments>
           <description>DF3380A digital frequency meter features:&lt;BR&gt;Adopting large-scale frequency measurement integrated circuits and ultra high speed frequency division circuits.&lt;BR&gt;It has four measurement functions: frequency measurement, cycle measurement, cumulative counting, and self checking.&lt;BR&gt;There are two measurement channels, HF and UHF.&lt;BR&gt;Eight digit digital display.&lt;BR&gt;Automatic decimal point positioning.&lt;BR&gt;The unit indicator light automatically displays.&lt;BR&gt;Equipped with overflow indicator.&lt;BR&gt;There is a standard frequency self-test function.&lt;BR&gt;Equipped with a low-pass filter.&lt;BR&gt;Novel plastic casing, compact and beautiful in appearance.&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;HF frequency measurement range: 10Hz to 100MHz&lt;BR&gt;UHF frequency measurement range: 100MHz~1.3GHz&lt;BR&gt;Periodic measurement range: 10Hz to 2.5MHz&lt;BR&gt;Counting measurement range: 108-1 (10Hz~10MHz)&lt;BR&gt;Frequency stability: 1 &#215; 10-5/day&lt;BR&gt;Maximum measurement sensitivity: better than 25mVrms&lt;BR&gt;Input impedance: 1M 次/35pF (HF channel) 50 次 (UHF channel).&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DF3390A digital frequency meter </title>
           <link>http://www.91way.com/info_en/8754.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:29</pubDate>
           <comments></comments>
           <description>DF3390A digital frequency meter features:&lt;BR&gt;&lt;BR&gt;Adopting large-scale frequency measurement integrated circuits and ultra high speed frequency division circuits.&lt;BR&gt;It has four measurement functions: frequency measurement, cycle measurement, cumulative counting, and self checking.&lt;BR&gt;There are two measurement channels, HF and UHF.&lt;BR&gt;Eight digit digital display.&lt;BR&gt;Automatic decimal point positioning.&lt;BR&gt;The unit indicator light automatically displays.&lt;BR&gt;Equipped with overflow indicator.&lt;BR&gt;There is a standard frequency self-test function.&lt;BR&gt;Equipped with a low-pass filter.&lt;BR&gt;Novel plastic casing, compact and beautiful in appearance.&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;&lt;BR&gt;HF frequency measurement range: 10Hz~10MHz&lt;BR&gt;UHF frequency measurement range: 100MHz~2.4GHz&lt;BR&gt;Periodic measurement range: 10Hz to 2.5MHz&lt;BR&gt;Counting measurement range: 108-1 (10Hz~10MHz)&lt;BR&gt;Frequency stability: 1 &#215; 10-5/day&lt;BR&gt;Maximum measurement sensitivity: better than 25mVrms&lt;BR&gt;Input impedance: 1M 次/35pF (HF channel) 50 次 (UHF channel)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]DH1001 Rubidium Atomic Frequency Standard </title>
           <link>http://www.91way.com/info_en/8753.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:20</pubDate>
           <comments></comments>
           <description>The DH1001 rubidium atomic frequency standard is a highly stable frequency source that utilizes the ground state hyperfine energy level transition spectral lines of rubidium isotope atoms to control the frequency of voltage controlled crystal oscillators. It is a passive atomic frequency standard. This instrument is suitable for time and frequency measurement, radio navigation and positioning, tracking of missiles and satellites, astronomical research, geological exploration, network synchronization of digital communication, precision timing and timing, etc.&lt;BR&gt;&lt;BR&gt;1. Frequency accuracy:&lt;BR&gt;a) Frequency calibration: The frequency accuracy at the factory should be better than 1 &#215; 10-10.&lt;BR&gt;b) Frequency adjustment range: The frequency adjustment range is greater than 2 &#215; 10-9.&lt;BR&gt;2. Frequency drift rate: The daily frequency drift rate is better than 2 &#215; 10-12/d.&lt;BR&gt;3. Frequency stability:&lt;BR&gt;&lt;BR&gt;Sampling time 而 1.0 seconds 10.0 seconds 100.0 seconds&lt;BR&gt;Stability 考 y (而) ≒ 1 &#215; 10-11 ≒ 3 &#215; 10-12 ≒ 1 &#215; 10-12&lt;BR&gt;&lt;BR&gt;4. Frequency startup characteristics: At 25 ⊥, the lock time is ≒ 5 minutes; After 10 minutes of startup, the frequency startup characteristic is ≒ 2 &#215; 10-10.&lt;BR&gt;5. Frequency temperature characteristics: In an environment of -10 to+50 ⊥, the frequency variation is ≒ 3 &#215; 10-10.&lt;BR&gt;6. The influence of geomagnetic field on frequency: The influence of geomagnetic field on frequency is ≒ 2 &#215; 10-11.&lt;BR&gt;7. Output frequency: 10MHz, 5MHz, 1MHz.&lt;BR&gt;8. Output amplitude (sine wave): The effective voltage value on a 50 次 load is 0.8V to 1.2V.&lt;BR&gt;9. Harmonic distortion: ≒ -40dB.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]AT-F3300C frequency meter </title>
           <link>http://www.91way.com/info_en/8752.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:12</pubDate>
           <comments></comments>
           <description>Product Introduction&lt;BR&gt;Eight digit LED display&lt;BR&gt;Less switches and simple operation&lt;BR&gt;Fast and high-resolution&lt;BR&gt;&lt;BR&gt;Technical indicators:&lt;BR&gt;&lt;BR&gt;Frequency range: 10Hz~3300MHz&lt;BR&gt;Display: 8-bit LED&lt;BR&gt;Gate time: 0.01S/0.1S/1S (seconds)&lt;BR&gt;Accuracy: &#177; 1Hz &#177; 1 digit &#177; Time base accuracy&lt;BR&gt;Input sensitivity: 10Hz~10MHz: 20mV (channel 1); 10MHz~100MHz: 25mV (channel 1); 100MHz~3300MHz: 25mV (channel 2)&lt;BR&gt;Input impedance: 1M 次 channel 1, 50 次 channel 2&lt;BR&gt;Maximum input voltage: 250VRMS channel 1; 5VRMS channel 2&lt;BR&gt;Maximum aging rate: &#177; 5ppm per year&lt;BR&gt;Power requirement: AC 220V &#177; 10% (50/60Hz)&lt;BR&gt;Power consumption: approximately 5W&lt;BR&gt;Size: 210 x 230 x 76 (LxWxH) mm&lt;BR&gt;Weight: 1.8kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[frequency meter]SX48 series microcomputer frequency meter </title>
           <link>http://www.91way.com/info_en/8556.html</link>
           <author></author>
           <guid></guid>
           <category>frequency meter</category>
           <pubDate>2026-6-16 16:19:04</pubDate>
           <comments></comments>
           <description>SX48 series microcomputer frequency meter external dimensions: 96 * 48 * 113mm opening size: 92 * 44mm&lt;BR&gt;&lt;BR&gt;SX48-F frequency meter&lt;BR&gt;&lt;BR&gt;A frequency meter is a multi-purpose, anti-interference intelligent instrument designed with a microcontroller&lt;BR&gt;&lt;BR&gt;</description>
       </item>
</channel>
</rss>

