           <title>[Discharge counter]JSY-11S type discharge counter </title>
           <link>http://www.91way.com/info_en/25352.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-14 10:53:45</pubDate>
           <comments></comments>
           <description>JSY-11S discharge counter&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JSZ-8 type discharge counter with electricity and lightning arrester fault indication </title>
           <link>http://www.91way.com/info_en/8156.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:42:25</pubDate>
           <comments></comments>
           <description>The JSZ-8 type discharge counter with power and lightning arrester fault indication has added the function of displaying the power and fault indication of the lightning arrester on the basis of the JSZ-8 type discharge counter, with passive and light-emitting diode indication&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JSQ-10 type discharge counter </title>
           <link>http://www.91way.com/info_en/8154.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:42:05</pubDate>
           <comments></comments>
           <description>Structure and Characteristics of JSQ-10 Discharge Counter&lt;BR&gt;&lt;BR&gt;1.1 This type of discharge counter has a fully plastic casing, with exposed metal parts made of stainless steel material;&lt;BR&gt;1.2 This type of counter is specially designed for miniaturization and is suitable for lightning arrester products with voltage levels of 35KV and below in compact environments;&lt;BR&gt;The discharge counter is mainly composed of a signal input circuit, a discharge counting circuit, and a protection circuit. When the lightning arrester is activated, the counter accumulates and records the number of discharges. After reaching full capacity, it automatically returns to zero and works in a cycle without resetting.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JS-8B type discharge counter </title>
           <link>http://www.91way.com/info_en/8153.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:41:56</pubDate>
           <comments></comments>
           <description>Structure and Characteristics of JS-8B Discharge Counter&lt;BR&gt;&lt;BR&gt;1.1 The counter housing, exposed body, and connectors are all made of stainless steel, and the glass panel is sealed with silicone and the housing. Fundamentally solving the problem of outdoor anti-corrosion, this counter is particularly used in power lines and heavily polluted areas;&lt;BR&gt;&lt;BR&gt;1.2 The discharge counter is mainly composed of a signal input circuit, a discharge counting circuit, and a protection circuit. When the lightning arrester is activated, a dual pointer counter is used to accumulate and record the number of discharges. The long pointer counts in units and automatically returns to zero after reaching full capacity. The short pointer counts in ten units, with one unit counting ten times. It works in a cycle counting mode and has the characteristic of recording multiple times.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JS-8A type discharge counter </title>
           <link>http://www.91way.com/info_en/8152.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:41:47</pubDate>
           <comments></comments>
           <description>Structure and Characteristics of JS-8A Discharge Counter&lt;BR&gt;The JS-8A discharge counter adopts a novel and unique overall structural design and an aluminum magnesium die-casting alloy shell, with a compact and sturdy structure, excellent sealing and shock resistance, stable and reliable operation, and easy transportation and installation; Widely used for lightning arresters in power stations, power lines, etc;&lt;BR&gt;1.2 It consists of a signal input circuit, a discharge counting circuit, and a protection circuit. When the lightning arrester is activated, the number of discharges is recorded by a clock pointer counter, and its performance complies with JB2440-91 &quot;Discharge Counter for Lightning Arresters&quot;;&lt;BR&gt;1.3 This type of counter is compatible with the JS-8 discharge counter, making it easy to install and exchange.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JSM-2/800 type discharge counter </title>
           <link>http://www.91way.com/info_en/7075.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:41:03</pubDate>
           <comments></comments>
           <description>JSM-2/800 discharge counter&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JS-1(TBP-J) series passive discharge counter </title>
           <link>http://www.91way.com/info_en/4953.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:37:59</pubDate>
           <comments></comments>
           <description>The JS-1 TBP overvoltage action counter is a device that performs real-time and cumulative counting of the working status of TBP products. Through this product, the TBP and the equipment protected by TBP can be monitored in detail, and abnormal situations before accidents can be predicted. To achieve the effect of analyzing the causes of abnormal actions and preventing accidents from occurring.&lt;BR&gt;Product structure and features:&lt;BR&gt;Each JS-1 TBP overvoltage action counter is a two-part structure, connected via RJ45 interface and Ethernet cable. Different installation methods can be adopted according to on-site needs. The counter adopts STN dot matrix LCD display, high-speed data processing unit, and software digital filtering.&lt;BR&gt;It has the characteristics of strong anti-interference ability, easy installation, and accurate counting. It can accurately record the number of actions between the three phases of TBP overvoltage protection in real time, and the recorded data can be accumulated by phase.&lt;BR&gt;Operation and maintenance:&lt;BR&gt;The TBP overvoltage action counter of the battery is designed passively and does not require an external power supply. The body comes with a battery that can be used for 3 years. If the battery is low, please contact our unit immediately for supply. The battery is located inside the data display box and can be replaced by opening the back cover. The statistical software design adopts real-time power-saving mode. When you need to observe data, please lightly touch the reading button once, and the accumulated overvoltage times between phases AB, AC, AD, BC, BD, and CD will be displayed in sequence. After the sequence is completed, the LCD display will automatically turn off.&lt;BR&gt;Clear, data needs to be cleared. Press and hold the button for one second. When &quot;ERASE&quot; appears, a dot will appear in one second. After all three dots appear, it means that data clearing is complete. During this process, if you need to give up clearing, release the button before the third point appears, and the reset will be canceled.&lt;BR&gt;&lt;BR&gt;Installation method of JS-1 (TBP-J) series passive discharge counter:&lt;BR&gt;1. Overall installation&lt;BR&gt;The display part of the TBP protector body mounted counter is directly hung on the protector.&lt;BR&gt;2. Split installation&lt;BR&gt;The display part of the counter installed on the cabinet door can be hung on the cabinet door, so the length of the signal line from the protector to the counter display part (must be specified when ordering) and the opening position and size of the cabinet door should be considered.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JSC cabinet counter </title>
           <link>http://www.91way.com/info_en/3559.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:13:13</pubDate>
           <comments></comments>
           <description>When the requirements for overvoltage monitoring are not high for JSC type cabinet counters, JSC cabinet counters can also be simplified to record the number of relative ground discharges.&lt;BR&gt;The JSC cabinet counter is designed with no residual voltage, and the sampling end is installed on the grounding phase of the three-phase combination product. The display end is external and can be directly mounted on the panel of the complete switchgear.&lt;BR&gt;&lt;BR&gt;This product has a low price, simple structure, and high practicality.&lt;BR&gt;The protective device is equipped with a counter, which is indicated by the letter &quot;J&quot; after its standard model.&lt;BR&gt;For example, FGB-10B-J indicates the installation of JSC counters on FGB products.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JC-2/800 Online Recorder </title>
           <link>http://www.91way.com/info_en/3125.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:08:58</pubDate>
           <comments></comments>
           <description>JC-2/800 lightning arrester online recorder&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JS7,JS9 series discharge counter </title>
           <link>http://www.91way.com/info_en/3048.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 19:00:26</pubDate>
           <comments></comments>
           <description>The JS-7 discharge counter is suitable for counting the number of actions of SiC valve type lightning arresters in AC power systems.&lt;BR&gt;The JS-9 discharge counter is suitable for counting the number of actions of metal oxide lightning arresters in AC power systems.&lt;BR&gt;&lt;BR&gt;Usage conditions for JS7 and JS9 series discharge counters&lt;BR&gt;Suitable for indoor and outdoor use&lt;BR&gt;The ambient temperature shall not be higher than+40 ¡æ and not lower than -40 ¡æ;&lt;BR&gt;Altitude not exceeding 2000m;&lt;BR&gt;&lt;BR&gt;Model Description&lt;BR&gt;JS-&amp;pound;&lt;BR&gt;©¦©¹ - Design No. 7: Used for silicon carbide lightning arrester; 9: Metal oxide lightning arrester&lt;BR&gt;&amp;#9394; - Counter&lt;BR&gt;&lt;BR&gt;characteristic&lt;BR&gt;The product adopts a glass cover with a large surface display, providing intuitive and clear readings;&lt;BR&gt;The product is compact in size and easy to install and use.&lt;BR&gt;Appearance, wiring terminals, and installation dimensions&lt;BR&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200804/2008429223015350.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 220px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JS7 and JS9 series discharge counters&quot; src=&quot;/uploadfiles/200804/2008429223015350.jpg&quot; width=680 height=220&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JS7, JS9 series discharge counters&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JSY series discharge counter </title>
           <link>http://www.91way.com/info_en/2286.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 18:47:36</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JSY series discharge counter is suitable for various types of silicon carbide and zinc oxide lightning arresters with voltage levels of 330KV and below, and is used under the same environmental conditions as the connected lightning arrester. This series of products adopts high-power zinc oxide valve plates, which have the characteristics of large flow capacity, wide adaptability to voltage levels, accurate and reliable action counting, and high sensitivity to lower limit action current. The JSY-8 discharge counter is a single pointer ten digit cyclic counting indicator; The JSY-8S model adopts a patented product dual pointer electromagnetic counter that has obtained national invention patents for counting indication. It has a counting carry function and can continuously count 100 times before entering the next counting cycle. It is suitable for use in areas with frequent lightning arrester actions and unmanned places. The JSY series discharge counter is enclosed in a transparent heat-resistant glass cover.&lt;BR&gt;&lt;BR&gt;The JSY series discharge counter is suitable for the following environmental conditions: 1. Altitude not exceeding 2000 meters; 2. The ambient temperature ranges from -40 ¡æ to+50 ¡æ; 3. Not suitable for gas environments with severe corrosion of metals and insulation components, as well as places with severe pollution and severe vibration.&lt;BR&gt;&lt;BR&gt;All performance indicators of the discharge counter product comply with the national machinery industry standard JB2440-91 &quot;Discharge Counter for Lightning Arresters&quot;. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical parameters of JSY series discharge counter:&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;JSY-8 5/400&lt;BR&gt;JSY-8S 5/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;JSY-8 10/600&lt;BR&gt;JSY-8S 10/600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;27%&quot;&gt;
&lt;DIV align=center&gt;JSY-8 10/1000&lt;BR&gt;JSY-8S 10/1000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;performance metrics&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Applicable power system rated voltage range (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10¡«110 KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10¡«220 KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10¡«220 KV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal discharge current 8/20uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Lower limit operating current 8/20uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Residual voltage at nominal discharge current (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.1KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.5KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.5KV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Square wave current withstand capacity 2000uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;400A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;600A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;High current impulse withstand capability 4/10uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;65KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Product weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.8kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.9kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200705/20075618136380.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 330px; WIDTH: 562px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JSY series discharge counter appearance and installation dimensions&quot; src=&quot;/uploadfiles/200705/20075618136380.gif&quot; width=562 height=330&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JSY series discharge counter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JS-8 discharge counter </title>
           <link>http://www.91way.com/info_en/808.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 18:29:01</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;The JS-8 discharge counter is suitable for various types of silicon carbide lightning arresters with voltage levels of 330KV and below, and is used under the same environmental conditions as the connected lightning arrester. This series of products uses high-temperature silicon carbide valve plates, which have the characteristics of large flow capacity, wide adaptability to voltage levels, and accurate and reliable action counting. The JS-8 discharge counter is a single pointer ten digit cyclic counting indicator; The JS-8S model is a dual pointer hundred digit cyclic counting indicator with counting carry function. It can count continuously for 100 times before entering the next counting cycle. It is suitable for use in areas with frequent lightning arrester actions and unmanned places. The JS series discharge counter is enclosed in a transparent heat-resistant glass cover.&lt;BR&gt;&lt;BR&gt;The JS-8 discharge counter is suitable for the following environmental conditions:&lt;BR&gt;1. Altitude not exceeding 2000 meters;&lt;BR&gt;2. The ambient temperature ranges from -40 ¡æ to+50 ¡æ;&lt;BR&gt;3. Not suitable for gas environments with severe corrosion of metals and insulation components, as well as places with severe pollution and severe vibration.&lt;BR&gt;&lt;BR&gt;All performance indicators of the discharge counter product comply with the national machinery industry standard JB2440-91 &quot;Discharge Counter for Lightning Arresters&quot;.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061029222822767.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 380px; WIDTH: 630px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JS-8 discharge counter&quot; src=&quot;/uploadfiles/200610/20061029222822767.gif&quot; width=630 height=380&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;JS-8 10/600&lt;BR&gt;JS-8S 10/600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;JS-8 10/1000&lt;BR&gt;JS-8S 10/1000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;performance metrics&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Applicable power system rated voltage range (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10¡«110 KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10¡«220 KV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal discharge current 8/20uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Lower limit operating current 8/20uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Residual voltage at nominal discharge current (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.1 kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.5 kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Square wave current withstand capacity 2000uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;600A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;High current impulse withstand capability 4/10uS (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Product weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.9kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JS-8 discharge counter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Discharge counter]JCQ Discharge Count Monitor </title>
           <link>http://www.91way.com/info_en/807.html</link>
           <author></author>
           <guid></guid>
           <category>Discharge counter</category>
           <pubDate>2026-6-13 18:28:52</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JCQ type lightning arrester monitor is a device that works in series below the lightning arrester to record the number of lightning arrester actions and monitor the leakage current of the lightning arrester. Suitable for various types of zinc oxide lightning arresters with voltage levels of 330KV and below, using the same environmental conditions as the connected lightning arrester. The JCQ series products are packaged in a transparent heat-resistant glass cover, mainly consisting of a transparent heat-resistant glass cover, flange, bottom plate, sealing gasket, high-power zinc oxide valve plate, rectifier, dual pointer electromagnetic counter, current measurement circuit, electronic alarm circuit, protection circuit, etc.&lt;BR&gt;&lt;BR&gt;Under normal use of the JCQ discharge counting monitor, the number of actions of the lightning arrester is indicated by a dual pointer electromagnetic counter with counting carry function. The counting indication is clear and eye-catching, and it automatically returns to zero when the hundred digits are full, continuing to cycle and accumulate counting work without resetting. The leakage current of the lightning arrester is directly reflected by the pointer ammeter through the current measurement circuit. The measurement indication range is 0-3 milliamps. When the leakage current exceeds the current alarm value set by the monitor, the alarm indicator light changes from white to red and sends out an alarm indication.&lt;BR&gt;&lt;BR&gt;The performance indicators of the monitor comply with the national mechanical industry standards JB/T 2440-1991 &quot;Discharge Counting Devices for Surge Arresters&quot;, JB/T 10492-2004 &quot;Monitor for AC gapless Metal Oxide Surge Arresters&quot;, and GB/T7676.1-1998 &quot;Pointer Electrical Instruments&quot;.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061029223155761.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 326px; WIDTH: 527px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCQ discharge counting monitor appearance and installation dimensions&quot; src=&quot;/uploadfiles/200610/20061029223155761.gif&quot; width=527 height=326&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;JCQ-A 10/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;JCQ-B 10/1200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;performance metrics&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Applicable power system rated voltage range (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;35¡«220KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;35¡«330KV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal counting current 8/20KA (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Lower limit counting current 8/20A (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Residual voltage (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.5KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.5KV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Square wave impulse current 2000A (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;800A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1200A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Impulse high current 4/10KA (peak)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Current measurement range and indication error (ACA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0¡«3mA&#177;%5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0¡«3mA&#177;%5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Product weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.7kg&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.8kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JCQ discharge counting monitor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
