<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Oil immersed discharge coil</title>
       <link>http://www.91way.com</link>
       <description>Oil immersed discharge coil</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:15:52</pubDate>
       <item>
           <title>[Oil immersed discharge coil]FDG2 series discharge coil </title>
           <link>http://www.91way.com/info_en/27519.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;FDG2 series discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2016/201609/20160905154333144.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 772px; WIDTH: 573px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDG2 series discharge coil technical parameters&quot; src=&quot;/upload2016/201609/20160905154333144.jpg&quot; width=573 height=772&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDE3 series discharge coil </title>
           <link>http://www.91way.com/info_en/27518.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;FDE3 series discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2016/201609/20160905154031717.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 588px; WIDTH: 571px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDE3 series discharge coil technical parameters&quot; src=&quot;/upload2016/201609/20160905154031717.jpg&quot; width=571 height=588&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FD21 series discharge coil </title>
           <link>http://www.91way.com/info_en/27517.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;FD21 series discharge coil&lt;BR&gt;&lt;BR&gt;Main technical data, external dimensions, and weight of the 66kV FD21-W series discharge coil--&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Model specifications&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage ratio&lt;BR&gt;(kV)&lt;/TD&gt;
&lt;TD align=center&gt;Dimensions (mm)&lt;BR&gt;Length &#215; Width &#215; Height&lt;BR&gt;L&#215;B&#215;H(mm)&lt;/TD&gt;
&lt;TD align=center&gt;base&lt;BR&gt;center distance&lt;BR&gt;A1&#215;B1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;Installation&lt;BR&gt;diameter&lt;BR&gt;&amp;Oslash;mm&lt;/TD&gt;
&lt;TD align=center&gt;Oil weight&lt;BR&gt;kg&lt;/TD&gt;
&lt;TD align=center&gt;Total weight&lt;BR&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD21-5&#215;2/21&#215;2-W&lt;/TD&gt;
&lt;TD align=center&gt;21&#215;2/100&#215;2&lt;/TD&gt;
&lt;TD align=center&gt;880&#215;520&#215;1400&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;450&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;eighty&lt;/TD&gt;
&lt;TD align=center&gt;three hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;P&gt;Note: All 66kV discharge coils must be equipped with isolation transformers&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2016/201609/20160905153744430.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 333px; WIDTH: 573px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FD21 series discharge coil technical parameters&quot; src=&quot;/upload2016/201609/20160905153744430.jpg&quot; width=573 height=333&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDME type discharge coil </title>
           <link>http://www.91way.com/info_en/26394.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The FDME type discharge coil is used in AC 50Hz, 6-35kV power systems, connected in parallel with a high-voltage parallel capacitor bank, so that the residual charge of the capacitor after being cut off from the power system can be quickly discharged, and the residual voltage of the capacitor reaches the required value within the specified time.&lt;BR&gt;This type of discharge coil has a secondary, rated voltage of 100V, and is used for relay protection.&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The FDME discharge coil adopts a fully sealed horizontal structure with reliable sealing performance, ensuring complete isolation between the insulating oil and the outside air. Its compensation method does not use an oil storage tank, but adopts an advanced structural compensation device. During operation, the discharge coil maintains a slight positive pressure inside the box (maximum&amp;lt;0.01Mpa, minimum&amp;gt;0.001Mpa). The sealing performance of each part is good, ensuring no oil leakage. It is a maintenance free product that does not require maintenance or replacement of components during its expected lifespan. The entire structure is reasonable, with excellent performance, small size, and beautiful appearance, making it your ideal choice.&lt;BR&gt;&lt;BR&gt;Model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141230190918384.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 145px; WIDTH: 582px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDME type discharge coil model description&quot; src=&quot;/upload2014/201412/20141230190918384.jpg&quot; width=582 height=145&gt;&lt;/A&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;1. Installation location: outdoor or indoor&lt;BR&gt;2. Environmental temperature: Outdoor -40 ¡æ~+40 ¡æ, -25 ¡æ~+45 ¡æ, -5 ¡æ~+55 ¡æ, indoor -5 ¡æ~+40 ¡æ&lt;BR&gt;3. Altitude: not exceeding 1000M&lt;BR&gt;4. Anti pollution ability: The external insulation creepage distance shall not be less than 31mm/kV (relative to the highest voltage of the system). For heavily polluted areas, the creepage distance should be appropriately increased.&lt;BR&gt;5. The installation location should be free of corrosive gases, steam, conductive or explosive dust.&lt;BR&gt;6. There is no severe mechanical vibration in the installation site.&lt;BR&gt;7. Maximum wind speed: 35m/s&lt;BR&gt;8. Relative humidity: For indoor discharge coils, the monthly average relative humidity should not exceed 90%, and the daily average relative humidity should not exceed 95%.&lt;BR&gt;&lt;BR&gt;connection method&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141230190936341.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 530px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDME type discharge coil wiring diagram&quot; src=&quot;/upload2014/201412/20141230190936341.jpg&quot; width=530 height=170&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Main ordering parameters&lt;BR&gt;1. Product specifications and models 2. Primary and secondary rated terminal voltage&lt;BR&gt;3. Accuracy level 4. Other special requirements&lt;BR&gt;5. Quantity 6. Supply date&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDZ2-10 outdoor discharge coil </title>
           <link>http://www.91way.com/info_en/19101.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:14</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201205/20120521093230840.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 294px; WIDTH: 597px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDZ2-10 outdoor discharge coil&quot; src=&quot;/upload2012/201205/20120521093230840.jpg&quot; width=597 height=294&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201205/20120521093240106.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 311px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of FDZ2-10 Outdoor Discharge Coil&quot; src=&quot;/upload2012/201205/20120521093240106.gif&quot; width=400 height=311&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDZ2-10 Outdoor Discharge Coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDEC11,FDEC21 series discharge coil </title>
           <link>http://www.91way.com/info_en/8653.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:54:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The FDEC11 and FDEC21 series discharge coils are used in AC 50Hz, 35kV power systems and are connected in parallel with high-voltage parallel capacitor banks. This allows the residual charge of the capacitors after being disconnected from the power system to be quickly discharged, and the residual voltage of the capacitors reaches the required value within the specified time.&lt;BR&gt;The FDEC11 and FDEC21 series discharge coils have a tap in the middle and two secondary windings, both with a voltage of 100V, for voltage differential protection.&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;1. Installation location: outdoor or indoor&lt;BR&gt;2. Environmental temperature: Outdoor -40 ¡æ~+40 ¡æ, -25 ¡æ~+45 ¡æ, -5 ¡æ~+55 ¡æ, indoor -5 ¡æ~+40 ¡æ&lt;BR&gt;3. Altitude: not exceeding 1000M&lt;BR&gt;4. Anti pollution ability: The external insulation creepage distance shall not be less than 25mm/kV (relative to the highest voltage of the system). For heavily polluted areas, the creepage distance should be appropriately increased.&lt;BR&gt;5. The installation location should be free of corrosive gases, steam, conductive or explosive dust.&lt;BR&gt;6. There is no severe mechanical vibration in the installation site.&lt;BR&gt;7. Maximum wind speed: 35m/s&lt;BR&gt;8. Relative humidity: For indoor discharge coils, the monthly average relative humidity should not exceed 90%, and the daily average relative humidity should not exceed 95%.&lt;BR&gt;&lt;BR&gt;Structural characteristics of FDEC11 and FDEC21 series discharge coils&lt;BR&gt;&lt;BR&gt;The FDEC11 and FDEC21 series discharge coils have two independent bodies that are not magnetically connected to each other. There are three high-voltage bushings and four low-voltage bushings on the box cover. There is a cylindrical oil storage tank on the high-pressure sleeve, and there is a valve on the oil storage tank that can be loosened during use. This type of discharge coil is fully sealed, and the oil in the tank does not come into contact with the outside air. Breathing relies on the rubber capsules in the oil storage tank. There is also an oil gauge on the oil storage tank, which shows the oil level at different temperatures.&lt;BR&gt;The maximum working voltage is 1.1 times the rated terminal voltage.&lt;BR&gt;Discharge time less than 5 seconds&lt;BR&gt;Temperature rise: coil&amp;lt;55 ¡æ (resistance method), oil level&amp;lt;50 ¡æ (thermometer method)&lt;BR&gt;Power frequency withstand voltage: 95kV Rated lightning impulse withstand voltage: 200kV&lt;BR&gt;Accuracy level: Level 1&lt;BR&gt;Rated voltage of the system: 35kV&lt;/P&gt;
&lt;P align=center&gt;FDEC11, FDEC21 series discharge coils&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDEC series discharge coil </title>
           <link>http://www.91way.com/info_en/8652.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:57</pubDate>
           <comments></comments>
           <description>The FDEC series discharge coil is used in AC 50Hz, 10kV power systems, connected in parallel with a high-voltage parallel capacitor bank, so that the residual charge of the capacitor after being cut off from the power system can be quickly discharged, and the residual voltage of the capacitor reaches the required value within the specified time. This type of discharge coil has a tap in the middle of the first stage and two secondary stages, both with a voltage of 100V, for voltage differential protection.&lt;BR&gt;&lt;BR&gt;FDEC/35/¡Ì 3-1.7 (FDEC/35/¡Ì 3-2.5) (FDEC/35/¡Ì 3-3.4) outdoor/oil immersed discharge coil structure introduction, model and meaning, product wiring diagram, main technical parameters, product insulation, external dimension drawing&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR5C-66kV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/7080.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:48</pubDate>
           <comments></comments>
           <description>FDR5C-66kV series fully sealed discharge coil&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3-20kV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/7079.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:40</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091020183917579.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1800px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of FDR3-20kV Series Fully Sealed Discharge Coil&quot; src=&quot;/upload2009/200910/20091020183917579.jpg&quot; width=680 height=1800&gt;&lt;/A&gt;&lt;BR&gt;FDR3-20kV series fully sealed discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3C-20kV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/7078.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/20091020183548447.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1600px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDR3C-20kV series fully sealed discharge coil&quot; src=&quot;/upload2009/200910/20091020183548447.jpg&quot; width=680 height=1600&gt;&lt;/A&gt;&lt;BR&gt;FDR3C-20kV series fully sealed discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FD2 series discharge coil </title>
           <link>http://www.91way.com/info_en/5201.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Main technical data, external dimensions, and weight of the 35kV FD21 series discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Model specifications&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage ratio&lt;BR&gt;(v/v)&lt;/TD&gt;
&lt;TD align=center&gt;Dimensions (mm)&lt;BR&gt;Length &#215; Width &#215; Height&lt;BR&gt;L&#215;B&#215;H(mm)&lt;/TD&gt;
&lt;TD align=center&gt;base&lt;BR&gt;center distance&lt;BR&gt;A1&#215;B1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;Installation&lt;BR&gt;diameter&lt;BR&gt;&amp;Oslash;mm&lt;/TD&gt;
&lt;TD align=center&gt;Oil weight&lt;BR&gt;kg&lt;/TD&gt;
&lt;TD align=center&gt;total weight&lt;BR&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/35/&lt;SPAN style=&quot;FONT-FAMILY: Symbol&quot;&gt;&amp;Ouml;&lt;/SPAN&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;20207/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;550&#215;1150&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;sixty-five&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/35&lt;/TD&gt;
&lt;TD align=center&gt;35000/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;550&#215;1150&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;sixty-five&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/38.5/&lt;SPAN style=&quot;FONT-FAMILY: Symbol&quot;&gt;&amp;Ouml;&lt;/SPAN&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;322228/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;550&#215;1150&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;sixty-five&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/38.5&lt;/TD&gt;
&lt;TD align=center&gt;38500/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;550&#215;1150&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;sixty-five&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/40/&lt;SPAN style=&quot;FONT-FAMILY: Symbol&quot;&gt;&amp;Ouml;&lt;/SPAN&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;23094/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;600&#215;1200&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and sixty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;FD2-5/42/&lt;SPAN style=&quot;FONT-FAMILY: Symbol&quot;&gt;&amp;Ouml;&lt;/SPAN&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;24249/100&lt;/TD&gt;
&lt;TD align=center&gt;650&#215;600&#215;1200&lt;/TD&gt;
&lt;TD align=center&gt;400&#215;350&lt;/TD&gt;
&lt;TD align=center&gt;twenty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and sixty&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: ¢Å The discharge capacity shown in the table refers to the external dimensions of various conventional discharge capacities that are the same as those of the same voltage level 
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201109/20110902165005901.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1800px; WIDTH: 576px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FD2 series discharge coil technical parameters&quot; src=&quot;/upload2011/201109/20110902165005901.gif&quot; width=576 height=1800&gt;&lt;/A&gt;&lt;BR&gt;FD2 series discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3 Type 10KV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/3800.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;FDR3 10KV Series Fully Sealed Discharge Coil Model Description&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191924668.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 167px; WIDTH: 389px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 10KV Series Fully Sealed Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/2008528191924668.gif&quot; width=389 height=167&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Purpose and Scope of Application&lt;BR&gt;After the parallel capacitor group installed in the substation is out of operation, there must be a discharge device to release the internal charge. For the capacitor group that implements automatic control switching, it is even more required to release its charge below the safe voltage within the specified time. Therefore, installing a dedicated discharge coil is a necessary technical safety measure for parallel capacitors in the substation.&lt;BR&gt;Considering the safety and reliability of parallel capacitor banks and their supporting equipment during operation, it is recommended to use a widely adopted single star wiring method for capacitor banks. The discharge coils are directly connected in parallel with each phase capacitor, and the secondary winding is connected in an open delta shape, which is connected to the protection relay to form an unbalanced voltage protection circuit as internal protection for the capacitor. If some components inside the capacitor are damaged or malfunctioning, it is required that the unbalanced voltage protection can detect and act on the switch to promptly disconnect the capacitor bank from the power grid. At this time, the discharge coil must have a sufficiently high accuracy level to ensure the performance and implementation of this protection. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Structure and Performance Characteristics of FDR3 10KV Series Fully Sealed Discharge Coil&lt;BR&gt;1. The box adopts a fully sealed horizontal structure, vacuum dried and oiled, with reliable sealing performance, ensuring complete isolation from the outside air. Its insulation oil compensation method adopts a unique structure and advanced compensation technology. Regardless of the highest and lowest temperature of the environment during operation throughout the year, the pressure inside the box always maintains a slight positive pressure (no more than 0.005Mpa at the highest and no less than 0.001Mpa at the lowest).&lt;BR&gt;2. The sealing performance of the box and ceramic sleeve is reliable, and there is no need for maintenance or replacement of parts during the expected service life, ensuring no oil leakage and explosion-proof function. It is a maintenance free product.&lt;BR&gt;3. The design parameters are reasonable and the accuracy level is high [at 0.9 to 1.3 times the rated frequency and 0 to 100% of the rated secondary load (cos ¦Õ=0.8 lag) to ensure accuracy level].&lt;BR&gt;4. Excellent volt ampere characteristics (within 1.9 times the rated voltage range, the iron core shows no obvious saturation trend to ensure linearity).&lt;BR&gt;5. The coverage of supporting capacitors (groups) is wide, simplifying the tedious selection work in the past.&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;a. Usage conditions: outdoor and indoor, ambient temperature; Class A -40~+40 ¡æ Class B -25~+45 ¡æ Class C -10~+55 ¡æ&lt;BR&gt;b. Altitude not exceeding 1000m&lt;BR&gt;c. Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will be damaged.&lt;BR&gt;d. Installation location: No harmful gases, vapors, or conductive or explosive dust.&lt;BR&gt;e. Maximum wind speed 35m/s&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDR3 10KV series fully sealed discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191954913.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 487px; WIDTH: 548px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDR3 10KV series fully sealed discharge coil&quot; src=&quot;/uploadfiles/200805/2008528191954913.gif&quot; width=548 height=487&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Outline installation dimension diagram 1&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852819205154.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 396px; WIDTH: 485px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 10KV series fully sealed discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200852819205154.gif&quot; width=485 height=396&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Connection method with capacitor (group)&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192017136.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 291px; WIDTH: 183px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 10KV series fully sealed discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528192017136.jpg&quot; width=183 height=291&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201301/20130112081314593.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 223px; WIDTH: 162px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of FDR3 10KV series fully sealed discharge coil&quot; src=&quot;/upload2013/201301/20130112081314593.jpg&quot; width=162 height=223&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDR3 10KV series fully sealed discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3C-10KV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/3799.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:53:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191559659.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 373px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-10KV Series Fully Sealed Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/2008528191559659.gif&quot; width=373 height=170&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Application and Scope of FDR3C-10KV Series Fully Sealed Discharge Coil&lt;BR&gt;&lt;BR&gt;Collective capacitors and parallel capacitors with large single capacity mainly rely on internal fuses to isolate faults and ensure the continued operation of capacitors due to internal component failures. Due to the unbalanced voltage of capacitors, the voltage on non fault phase capacitors and healthy components in fault phases will increase. When a single star shaped parallel capacitor group is connected to each phase capacitor using two or more series sections or a collective capacitor with a middle tap, its internal protection can also use high-sensitivity differential pressure protection. The discharge coil with a middle tap is connected to the corresponding tap of each phase capacitor to form a differential pressure protection circuit, which can act on the switch to promptly remove the capacitor from the grid when the voltage on the healthy component exceeds the allowable safe working value. The FDR3C fully sealed discharge coil is a all-weather product designed specifically for this differential pressure protection wiring method, with ideal discharge performance. And ensure its protection sensitivity requirements with its high differential pressure measurement precision. &amp;nbsp;&lt;BR&gt;FDR3C fully sealed discharge coil, high-voltage coil with center tap A2, suitable for parallel capacitors (groups) using differential pressure protection. A2 is connected to the corresponding middle terminal of the capacitor (group), and its voltage corresponds to 50% of the voltage of A1 and X at the middle tap of the parallel capacitor (note: other corresponding values can also be designed according to user requirements, such as the voltage ratio of A1, A2, X being 4:6 or 6:4 or other values). &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Structure and performance characteristics&lt;BR&gt;a. The FDR3C outdoor dry discharge coil adopts two independent new high-quality iron cores, a fully insulated structure, and each has a secondary coil. The structure is reasonable, the power consumption is low, the temperature rise is low, and the accuracy requirements of differential pressure protection are ensured. &amp;nbsp;&lt;BR&gt;b¡¢ The fuel tank adopts a fully sealed horizontal structure, vacuum dried oil injection, reliable sealing performance, and ensures complete isolation from the outside air. Its insulation oil compensation method adopts advanced compensation technology with a unique structure. Regardless of whether it operates at the highest or lowest temperature of the environment throughout the year, the pressure inside the tank always maintains a slight positive pressure (no more than 0.005Mpa at the highest and no less than 0.001Mpa at the lowest).&lt;BR&gt;c¡¢ The sealing performance of the horizontal fuel tank body and ceramic sleeve is reliable, and there is no need for maintenance or replacement of components during the expected service life, ensuring no oil leakage and explosion-proof function. It is a maintenance free product. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDR3C-10KV series fully sealed discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191611297.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 474px; WIDTH: 540px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDR3C-10KV series fully sealed discharge coil&quot; src=&quot;/uploadfiles/200805/2008528191611297.gif&quot; width=540 height=474&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Environmental conditions for the use of FDR3C-10KV series fully sealed discharge coils&lt;BR&gt;&lt;BR&gt;a. Usage conditions: outdoor and indoor, ambient temperature;&lt;BR&gt;Class A -40~+40 ¡æ&lt;BR&gt;Class B -25~+45 ¡æ&lt;BR&gt;Class C -10~+55 ¡æ&lt;BR&gt;&lt;BR&gt;b. Altitude not exceeding 1000m&lt;BR&gt;c. Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will be damaged.&lt;BR&gt;d. Installation location: No harmful gases, vapors, or conductive or explosive dust.&lt;BR&gt;e. Maximum wind speed 35m/s&lt;BR&gt;&lt;BR&gt;Connection method with capacitor (group)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191632240.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 228px; WIDTH: 335px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-10KV series fully sealed discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528191632240.jpg&quot; width=335 height=228&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Exterior installation dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191641824.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 410px; WIDTH: 470px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-10KV series fully sealed discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008528191641824.jpg&quot; width=470 height=410&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDR3C-10KV series fully sealed discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR5-66kV Series Fully Sealed Discharge Coil </title>
           <link>http://www.91way.com/info_en/3796.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:52:57</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;&lt;A href=&quot;/uploadfiles/200805/200852819323803.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 168px; WIDTH: 353px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR5-66kV Series Fully Sealed Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/200852819323803.jpg&quot; width=353 height=168&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Application and Scope of FDR5-66kV Series Fully Sealed Discharge Coil&lt;BR&gt;&lt;BR&gt;After the parallel capacitor bank installed in the substation is out of operation, it must have a discharge device to release the internal charge. For the capacitor bank that implements automatic control switching, it is even more required to release its charge below the safe voltage within the specified time. Therefore, installing dedicated discharge coils is a necessary technical safety measure for parallel capacitors in substations.&lt;BR&gt;&lt;BR&gt;Considering the safety and reliability of parallel capacitor banks and their supporting equipment during operation, it is recommended to use a widely adopted single star wiring method for capacitor banks. The discharge coils are directly connected in parallel with each phase capacitor, and the secondary windings are connected in an open triangle shape, forming an unbalanced voltage protection circuit with the protection relay as internal protection for the capacitor. If any component inside a capacitor of any phase in the capacitor bank is damaged or faulty, it is required that the unbalanced voltage protection can detect and activate the switch to promptly disconnect the capacitor bank from the power grid. At this time, the discharge coil must have a sufficiently high accuracy level to ensure the implementation of this protection performance.&lt;BR&gt;&lt;BR&gt;Structure and performance characteristics&lt;BR&gt;1. The box adopts a fully sealed horizontal structure with vacuum drying and oil injection, ensuring reliable sealing performance and complete isolation from the outside world. Its insulation oil compensation method adopts a unique structure and advanced compensation technology. Regardless of whether it operates at the highest or lowest temperature of the environment throughout the year, the pressure inside the box always maintains a slight positive pressure (no more than 0.005Mpa at the highest and no less than 0.001Mpa at the lowest)&lt;BR&gt;2. The sealing performance of the box and ceramic sleeve is reliable, and there is no need for maintenance or replacement of parts within the expected service life, ensuring no oil leakage and explosion-proof function. It is a maintenance free product.&lt;BR&gt;3. Reasonable design parameters, high accuracy level [at rated frequency 0.9 times -1.3 times rated voltage and 0-100% rating]&lt;BR&gt;Fixed secondary load (COS with 0.8 lag) to ensure accuracy level.&lt;BR&gt;4. Excellent volt ampere characteristics (within 1.5 times the rated voltage range, the iron core shows no obvious saturation trend, ensuring reliability)&lt;BR&gt;Linear degree).&lt;BR&gt;5. The coverage of supporting capacitors (groups) is wide, simplifying the tedious selection work in the past&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDR5-66kV series fully sealed discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852819335545.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 346px; WIDTH: 418px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDR5-66kV series fully sealed discharge coil&quot; src=&quot;/uploadfiles/200805/200852819335545.jpg&quot; width=418 height=346&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Environmental conditions for use&lt;BR&gt;a¡¢ Usage conditions: indoor and outdoor, ambient temperature; &amp;nbsp;&lt;BR&gt;Class A -40 to+40 &#176; C&lt;BR&gt;Class B -25 to+45 &#176; C&lt;BR&gt;Class C -10 to+55 &#176; C&lt;BR&gt;b¡¢ Altitude not exceeding 1000m;&lt;BR&gt;C¡¢ Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will not be damaged;&lt;BR&gt;d¡¢ Installation location: No harmful gases, vapors, or conductive or explosive dust;&lt;BR&gt;e¡¢ Maximum wind speed: 35m/s.&lt;BR&gt;&lt;BR&gt;Connection method with capacitor (group)&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852819517944.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 148px; WIDTH: 517px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR5-66kV series fully sealed discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/200852819517944.jpg&quot; width=517 height=148&gt;&lt;/A&gt;&lt;BR&gt;Outline and installation dimension diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085281948609.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 842px; WIDTH: 482px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR5-66kV series fully sealed discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/20085281948609.jpg&quot; width=482 height=842&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDR5-66kV series fully sealed discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3 type 35kV outdoor discharge coil </title>
           <link>http://www.91way.com/info_en/3460.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:52:49</pubDate>
           <comments></comments>
           <description>&lt;A href=&quot;/uploadfiles/200805/2008528192551787.gif&quot; target=_blank&gt;&lt;/A&gt;
&lt;P&gt;Fully sealed discharge coil for high-voltage parallel capacitors&lt;BR&gt;&lt;BR&gt;FDR3 (35KV) series fully sealed discharge coil, overview of applicability, structure, performance, and characteristics&lt;BR&gt;&lt;BR&gt;Model Description&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192551787.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 167px; WIDTH: 389px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 Type 35kV Outdoor Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/2008528192551787.gif&quot; width=389 height=167&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Purpose and Scope of Application&lt;BR&gt;After the FDR3 type 35kV outdoor discharge coil is installed in the parallel capacitor bank of the substation, there must be a discharge device to release the internal charge. For the capacitor bank that implements automatic control switching, it is even more required to release its charge below the safe voltage within the specified time. Therefore, installing a dedicated discharge coil is a necessary technical safety measure for parallel capacitors in the substation.&lt;BR&gt;Considering the safety and reliability of parallel capacitor banks and their supporting equipment during operation, it is recommended to use a widely adopted single star wiring method for capacitor banks. The discharge coils are directly connected in parallel with each phase capacitor, and the secondary winding is connected in an open delta shape, which is connected to the protection relay to form an unbalanced voltage protection circuit as internal protection for the capacitor. If some components inside the capacitor are damaged or malfunctioning, it is required that the unbalanced voltage protection can detect and act on the switch to promptly disconnect the capacitor bank from the power grid. At this time, the discharge coil must have a sufficiently high accuracy level to ensure the performance and implementation of this protection. &amp;nbsp;&lt;BR&gt;Structure and performance characteristics&lt;BR&gt;1. The box adopts a fully sealed horizontal structure, vacuum dried and oiled, with reliable sealing performance, ensuring complete isolation from the outside air. Its insulation oil compensation method adopts a unique structure and advanced compensation technology. Regardless of the highest and lowest temperature of the environment during operation throughout the year, the pressure inside the box always maintains a slight positive pressure (no more than 0.005Mpa at the highest and no less than 0.001Mpa at the lowest).&lt;BR&gt;2. The sealing performance of the box and ceramic sleeve is reliable, and there is no need for maintenance or replacement of parts during the expected service life, ensuring no oil leakage and explosion-proof function. It is a maintenance free product.&lt;BR&gt;3. The design parameters are reasonable and the accuracy level is high [at 0.9 to 1.3 times the rated frequency and 0 to 100% of the rated secondary load (cos ¦Õ=0.8 lag) to ensure accuracy level].&lt;BR&gt;4. Excellent volt ampere characteristics (within 1.9 times the rated voltage range, the iron core shows no obvious saturation trend to ensure linearity).&lt;BR&gt;5. The coverage of supporting capacitors (groups) is wide, simplifying the tedious selection work in the past.&lt;BR&gt;Environmental conditions for use&lt;BR&gt;a. Usage conditions: outdoor and indoor, ambient temperature;&lt;BR&gt;Class A -40~+40 ¡æ&lt;BR&gt;Class B -25~+45 ¡æ&lt;BR&gt;Class C -10~+55 ¡æ&lt;BR&gt;b. Altitude not exceeding 1000m&lt;BR&gt;c. Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will be damaged.&lt;BR&gt;d. Installation location: No harmful gases, vapors, or conductive or explosive dust.&lt;BR&gt;e. Maximum wind speed 35m/s&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDR3 35kV outdoor discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192622696.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 487px; WIDTH: 548px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDR3 35kV outdoor discharge coil&quot; src=&quot;/uploadfiles/200805/2008528192622696.gif&quot; width=548 height=487&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Connection method with capacitor (group)&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192633417.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 291px; WIDTH: 183px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 type 35kV outdoor discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528192633417.jpg&quot; width=183 height=291&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Outline installation dimension diagram&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192648215.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 479px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3 type 35kV outdoor discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008528192648215.gif&quot; width=550 height=479&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDR3 type 35kV outdoor discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDR3C-35kV type outdoor discharge coil </title>
           <link>http://www.91way.com/info_en/3353.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:52:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;/uploadfiles/200805/20085128299619.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 266px; WIDTH: 403px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-35kV Outdoor Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/20085128299619.jpg&quot; width=403 height=266&gt;&lt;/A&gt;&lt;BR&gt;Purpose and Scope of Application&lt;BR&gt;Collective capacitors and parallel capacitors with large single capacity mainly rely on internal fuses to isolate faults and ensure the continued operation of capacitors due to internal component failures. Due to the unbalanced voltage of capacitors, the voltage on non fault phase capacitors and healthy components in fault phases will increase. When a single star shaped parallel capacitor group is connected to each phase capacitor using two or more series sections or a collective capacitor with a middle tap, its internal protection can also use high-sensitivity differential pressure protection. The discharge coil with a middle tap is connected to the corresponding tap of each phase capacitor to form a differential pressure protection circuit, which can act on the switch to promptly remove the capacitor from the grid when the voltage on the healthy component exceeds the allowable safe working value. The FDR3C fully sealed discharge coil is a all-weather product designed specifically for this differential pressure protection wiring method, with ideal discharge performance. And ensure its protection sensitivity requirements with its high differential pressure measurement precision. &amp;nbsp;&lt;BR&gt;FDR3C fully sealed discharge coil, high-voltage coil with center tap A2, suitable for parallel capacitors (groups) using differential pressure protection. A2 is connected to the corresponding middle terminal of the capacitor (group), and its voltage corresponds to 50% of the voltage of A1 and X at the middle tap of the parallel capacitor (note: other corresponding values can also be designed according to user requirements, such as the voltage ratio of A1, A2, X being 4:6 or 6:4 or other values). &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Structure and performance characteristics&lt;BR&gt;a. The FDR3C fully sealed discharge coil adopts two independent high-quality iron cores, a fully insulated structure, and each has a secondary coil. The structure is reasonable, the power consumption is low, the temperature rise is low, and the accuracy requirements of differential pressure protection are ensured. &amp;nbsp;&lt;BR&gt;b¡¢ The fuel tank adopts a fully sealed horizontal structure, vacuum dried oil injection, reliable sealing performance, and ensures complete isolation from the outside air. Its insulation oil compensation method adopts advanced compensation technology with a unique structure. Regardless of whether it operates at the highest or lowest temperature of the environment throughout the year, the pressure inside the tank always maintains a slight positive pressure (no more than 0.005Mpa at the highest and no less than 0.001Mpa at the lowest).&lt;BR&gt;c¡¢ The sealing performance of the horizontal fuel tank body and ceramic sleeve is reliable, and there is no need for maintenance or replacement of components during the expected service life, ensuring no oil leakage and explosion-proof function. It is a maintenance free product. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDR3C-35kV outdoor discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192311617.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 474px; WIDTH: 540px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDR3C-35kV outdoor discharge coil&quot; src=&quot;/uploadfiles/200805/2008528192311617.gif&quot; width=540 height=474&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Environmental conditions for use&lt;BR&gt;a. Usage conditions: outdoor and indoor, ambient temperature;&lt;BR&gt;Class A -40~+40 ¡æ&lt;BR&gt;Class B -25~+45 ¡æ&lt;BR&gt;Class C -10~+55 ¡æ&lt;BR&gt;b. Altitude not exceeding 1000m&lt;BR&gt;c. Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will be damaged.&lt;BR&gt;d. Installation location: No harmful gases, vapors, or conductive or explosive dust.&lt;BR&gt;e. Maximum wind speed 35m/s&lt;BR&gt;&lt;BR&gt;Connection method with capacitor (group)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192319379.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 228px; WIDTH: 335px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-35kV outdoor discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528192319379.jpg&quot; width=335 height=228&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Outline installation dimension diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528192331920.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 309px; WIDTH: 526px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDR3C-35kV outdoor discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008528192331920.jpg&quot; width=526 height=309&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201301/20130112081503669.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 250px; WIDTH: 162px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of FDR3C-35kV outdoor discharge coil&quot; src=&quot;/upload2013/201301/20130112081503669.jpg&quot; width=162 height=250&gt;&lt;/A&gt;&lt;BR&gt;FDR3C-35kV outdoor discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Oil immersed discharge coil]FDZR-1.7 type discharge coil </title>
           <link>http://www.91way.com/info_en/3171.html</link>
           <author></author>
           <guid></guid>
           <category>Oil immersed discharge coil</category>
           <pubDate>2026-6-20 21:52:32</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008538526466.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 934px; WIDTH: 560px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDZR-1.7 discharge coil&quot; src=&quot;/uploadfiles/200805/2008538526466.gif&quot; width=560 height=934&gt;&lt;/A&gt;&lt;BR&gt;FDZR-1.7 discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
