       <item>
           <title>[Dry discharge coil]FDGZBX8-1.7,2.5,3.4-1(W)(G) series dry discharge coil </title>
           <link>http://www.91way.com/info_en/26187.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:58:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141220061514522.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 504px; WIDTH: 614px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of FDGZBX8-1.7,2.5,3.4-1 (W) (G) series dry discharge coils&quot; src=&quot;/upload2014/201412/20141220061514522.jpg&quot; width=614 height=504&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141220061520191.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 469px; WIDTH: 612px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGZBX8-1.7,2.5,3.4-1 (W) (G) series dry discharge coil technical parameters&quot; src=&quot;/upload2014/201412/20141220061520191.jpg&quot; width=612 height=469&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGZBX8-1.7,2.5,3.4-1 (W) (G) series dry discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDZR2-4.0/12(-1W) type discharge coil </title>
           <link>http://www.91way.com/info_en/25225.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:58:30</pubDate>
           <comments></comments>
           <description>The FDZR2-4.0/12/¡Ì 3 (-1W) discharge coil is a fully enclosed structure made of (outdoor) epoxy resin casting, suitable for connecting with high-voltage parallel capacitors in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It enables the rapid release of residual charges after the capacitor bank is disconnected from the power system, effectively preventing the occurrence of closing overvoltage and overcurrent that may endanger equipment safety due to the capacitor still carrying charges when the capacitor bank is closed again, and ensuring the safety of maintenance personnel. This series of products comes with a secondary winding, which can be used for line monitoring, measurement, and secondary protection.&lt;BR&gt;&lt;BR&gt;Technical parameters of FDZR2-4.0/12/¡Ì 3 (-1W) discharge coil&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;System nominal voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;Rated voltage of primary winding (kV)&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;6.6/¡Ì3£» 7.2/¡Ì3£» 11/¡Ì3£» 12/¡Ì3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;Rated voltage of secondary winding (V)&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;100£» 100/¡Ì3&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;Rated load of secondary winding (VA)&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;50VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;Supporting capacitor bank capacity (Mvar)&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;0.5-4.0&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;12/42/75kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;discharge time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;At rated operating voltage, the residual voltage of the capacitor shall not drop to 50V for more than 5 seconds after power failure&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;Partial discharge level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=444 colSpan=2&gt;
&lt;DIV&gt;¡Ü5pC&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=198&gt;
&lt;DIV&gt;Wiring method: Reduced level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=204&gt;
&lt;DIV&gt;Number of phases: single-phase&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=240&gt;
&lt;DIV&gt;Frequency: 50Hz&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=642 colSpan=3&gt;
&lt;DIV&gt;Creepage distance: The external insulation creepage distance shall not be less than 31mm/kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: If there are special requirements, they can be determined after consultation with our company.&lt;BR&gt;&lt;BR&gt;Product outline drawing:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201405/20140514044320816.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 365px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of FDZR2-4.0/12 (-1W) discharge coil&quot; src=&quot;/upload2014/201405/20140514044320816.jpg&quot; width=680 height=365&gt;&lt;/A&gt;&lt;BR&gt;FDZR2-4.0/12 (-1W) discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE9-1W type fully enclosed outdoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/24203.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:58:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The FDGE9-1W fully enclosed outdoor dry discharge coil is an epoxy resin vacuum cast single-phase outdoor fully enclosed product, suitable for power systems with a rated frequency of 50 Hz and a rated voltage of 10kV and below. Connect in parallel with the high-voltage parallel capacitor bank, and when the capacitor bank is disconnected from the system, reduce the remaining voltage on the capacitor bank to a safe voltage within 5 seconds. During normal operation, the secondary winding can serve as a voltage indicator. If the user has special requirements, the residual voltage winding can also be included to provide relay protection.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131207192509127.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 398px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of FDGE9-1W Fully Enclosed Outdoor Dry Discharge Coil&quot; src=&quot;/upload2013/201312/20131207192509127.jpg&quot; width=600 height=398&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;This type of discharge coil adopts a fully sealed structure with resin cast insulation for the iron core. The iron core is made of high-quality cold-rolled steel sheets and is cast together with the primary and secondary windings using advanced vacuum casting technology. It is an ideal product to replace oil immersed discharge coils due to its small size, light weight, small no-load capacity, strong overvoltage resistance, easy installation and use, and maintenance free.&lt;BR&gt;&lt;BR&gt;Technical parameters:&lt;BR&gt;Product execution standard: DL/T653-2006&lt;BR&gt;Technical Specifications for Ordering Discharge Coils for Voltage Parallel Capacitors;&lt;BR&gt;Load power factor: COS=0.8 (lag);&lt;BR&gt;Surface creepage distance: greater than 300mm;&lt;BR&gt;&lt;BR&gt;The technical parameters of FDGE9-1W fully enclosed outdoor dry discharge coil are shown in the following table:&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131207192534707.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 190px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDGE9-1W fully enclosed outdoor dry discharge coil&quot; src=&quot;/upload2013/201312/20131207192534707.jpg&quot; width=600 height=190&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Appearance dimensions:&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131207192551604.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 477px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of FDGE9-1W fully enclosed outdoor dry discharge coil&quot; src=&quot;/upload2013/201312/20131207192551604.jpg&quot; width=600 height=477&gt;&lt;/A&gt;&lt;BR&gt;FDGE9-1W fully enclosed outdoor dry discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE35 type discharge coil </title>
           <link>http://www.91way.com/info_en/22971.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:58:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130313083351722.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 96px; WIDTH: 644px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDGE35 discharge coil&quot; src=&quot;/upload2013/201303/20130313083351722.jpg&quot; width=644 height=96&gt;&lt;/A&gt;&lt;BR&gt;FDGE35 discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE11 type discharge coil </title>
           <link>http://www.91way.com/info_en/22970.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:58:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;FDGE11 type discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130313082828343.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 210px; WIDTH: 639px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDGE11 discharge coil&quot; src=&quot;/upload2013/201303/20130313082828343.jpg&quot; width=639 height=210&gt;&lt;/A&gt;&lt;BR&gt;FDGE11 type discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE6 type semi enclosed indoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/19918.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:56</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120811182533211.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 607px; WIDTH: 510px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and external dimensions of FDGE6 semi enclosed indoor dry discharge coil&quot; src=&quot;/upload2012/201208/20120811182533211.jpg&quot; width=510 height=607&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGE6 semi enclosed indoor dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE10 type fully enclosed indoor dry-type discharge coil </title>
           <link>http://www.91way.com/info_en/19917.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:48</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120811182231237.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 701px; WIDTH: 503px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDGE10 fully enclosed indoor dry discharge coil&quot; src=&quot;/upload2012/201208/20120811182231237.jpg&quot; width=503 height=701&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGE10 fully enclosed indoor dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGZ(C) type fully enclosed outdoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/16712.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201108/20110823080955162.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 260px; WIDTH: 682px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGZ (C) Type Fully Enclosed Outdoor Dry Discharge Coil Model Description&quot; src=&quot;/upload2011/201108/20110823080955162.jpg&quot; width=682 height=260&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;FDGZ (C) type fully enclosed outdoor dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE9 type discharge coil </title>
           <link>http://www.91way.com/info_en/16017.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:30</pubDate>
           <comments></comments>
           <description>The FDGE9 discharge coil is suitable for power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 10kV and below. It is connected in parallel with a high-voltage parallel capacitor bank. When the capacitor bank is disconnected from the system, it can reduce the remaining voltage on the capacitor bank to a safe voltage within 5 seconds. During normal operation, the secondary winding can serve as a voltage indicator. If the user has special requirements, the residual voltage winding can also be included to provide relay protection.&lt;BR&gt;The product complies with the technical specifications for ordering discharge coils for voltage parallel capacitors (DL/T 653-1998).&lt;BR&gt;&lt;BR&gt;Model and its meaning&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404094337426.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 288px; WIDTH: 483px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGE9 type discharge coil model description&quot; src=&quot;/upload2011/201104/20110404094337426.jpg&quot; width=483 height=288&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Normal usage conditions&lt;BR&gt;Installation location: Indoor.&lt;BR&gt;Environmental temperature: maximum temperature of 40 ¡æ; Minimum temperature -5 ¡æ; The daily average temperature does not exceed 30 ¡æ.&lt;BR&gt;Atmospheric conditions: There is no severe pollution in the atmosphere.&lt;BR&gt;&lt;BR&gt;Technical parameters of FDGE9 discharge coil&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=3 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;rated voltage ratio&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;Accuracy level or combination of accuracy levels&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;rated output&lt;BR&gt;(VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;discharge capacity&lt;BR&gt;(Mvar)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE9/6.6/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6.6/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=9&gt;
&lt;DIV align=center&gt;one point seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;7.2/32/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6.6/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;BR&gt;FDGE9/7.2/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.2/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.2/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE9/11/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;11/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;11/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE9/12/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Rated insulation level: 0.5/3kV&lt;BR&gt;&lt;BR&gt;Structure and Characteristics&lt;BR&gt;This series of discharge coils adopts a pillar structure and is made of fully enclosed epoxy resin casting, which is resistant to pollution and moisture. It is also suitable for use in tropical regions. The transformer does not require special maintenance, only regular cleaning of surface dirt is needed. Install a wiring terminal box at the secondary output terminal of the transformer. There is a hole on the front and side of the terminal box to match the output terminal for safe and reliable wiring. There are grounding bolts and six mounting holes for installation on the product base plate.&lt;BR&gt;&lt;BR&gt;Outline drawing and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110404094355503.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 650px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGE9 discharge coil appearance and installation dimensions&quot; src=&quot;/upload2011/201104/20110404094355503.jpg&quot; width=680 height=650&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Ordering Instructions&lt;BR&gt;Please provide the following parameters when placing an order:&lt;BR&gt;Product model.&lt;BR&gt;The rated voltage is in kV.&lt;BR&gt;Accurate level combination and rated output VA.&lt;BR&gt;Discharge capacity Mvar.&lt;BR&gt;The altitude of the environment is m.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGE8 type discharge coil </title>
           <link>http://www.91way.com/info_en/16016.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:22</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The FDGE8 discharge coil is suitable for power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 10kV and below. It is connected in parallel with a high-voltage parallel capacitor bank. When the capacitor bank is disconnected from the system, it can reduce the remaining voltage on the capacitor bank to a safe voltage within 5 seconds. During normal operation, the secondary winding can serve as a voltage indicator. If the user has special requirements, the residual voltage winding can also be included to provide relay protection.&lt;BR&gt;The product complies with the technical specifications for ordering discharge coils for voltage parallel capacitors (DL/T 653-1998).&lt;BR&gt;&lt;BR&gt;Model and its meaning&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404094008258.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 286px; WIDTH: 478px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGE8 type discharge coil model description&quot; src=&quot;/upload2011/201104/20110404094008258.jpg&quot; width=478 height=286&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Normal usage conditions&lt;BR&gt;Installation location: Indoor.&lt;BR&gt;Environmental temperature: maximum temperature of 40 ¡æ; Minimum temperature -5 ¡æ; The daily average temperature does not exceed 30 ¡æ.&lt;BR&gt;Atmospheric conditions: There is no severe pollution in the atmosphere.&lt;BR&gt;&lt;BR&gt;Technical parameters of FDGE8 discharge coil&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=3 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;rated voltage ratio&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;Accuracy level or combination of accuracy levels&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;rated output&lt;BR&gt;(VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;discharge capacity&lt;BR&gt;(Mvar)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE8/6.6/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6.6/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=9&gt;
&lt;DIV align=center&gt;one point seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;7.2/32/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6.6/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;BR&gt;FDGE8/7.2/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.2/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.2/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE8/11/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;11/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;11/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;FDGE8/12/¡Ì3-1.7-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12/¡Ì3/0.1/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2(0.5)/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20(50)/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Rated insulation level: 0.5/3kV&lt;BR&gt;&lt;BR&gt;Structure and Characteristics&lt;BR&gt;This series of discharge coils is a semi enclosed epoxy casting type, with the iron core made of high-quality silicon steel sheets stacked together. The casting body contains a cylindrical concentric combination of primary and secondary coils. There are grounding bolts and four mounting holes for installation on the bottom clamp of the product.&lt;BR&gt;&lt;BR&gt;Outline drawing and installation dimensions of FDGE8 discharge coil&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404094030921.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 600px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of FDGE8 discharge coil&quot; src=&quot;/upload2011/201104/20110404094030921.jpg&quot; width=680 height=600&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ordering Instructions&lt;BR&gt;Please provide the following parameters when placing an order:&lt;BR&gt;Product model.&lt;BR&gt;The rated voltage is in kV.&lt;BR&gt;Accurate level combination and rated output VA.&lt;BR&gt;Discharge capacity Mvar.&lt;BR&gt;The altitude of the environment is m.&lt;BR&gt;Note: If users have special requirements, they can negotiate with our company to determine.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDEG8 type discharge coil </title>
           <link>http://www.91way.com/info_en/8654.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:13</pubDate>
           <comments></comments>
           <description>FDEG8 type discharge coil&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGRC-20kV series outdoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/7077.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:57:05</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200910/20091020183214191.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1600px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGRC-20kV series outdoor dry discharge coil technical parameters and installation dimensions&quot; src=&quot;/upload2009/200910/20091020183214191.jpg&quot; width=680 height=1600&gt;&lt;/A&gt;&lt;BR&gt;FDGRC-20kV series outdoor dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGR-20kV series outdoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/7076.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200910/2009102018294409.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1600px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDGR-20kV series outdoor dry discharge coil&quot; src=&quot;/upload2009/200910/2009102018294409.jpg&quot; width=680 height=1600&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;FDGR-20kV series outdoor dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGRC-35kV series outdoor dry discharge coil </title>
           <link>http://www.91way.com/info_en/3798.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:48</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1¡¢ Usage and Application&lt;BR&gt;The FDGRC-35kV series outdoor dry-type discharge coil is a single-phase fully enclosed outdoor product used in power systems to connect with high-voltage parallel capacitors, allowing the capacitor bank to quickly release the charge after being disconnected from the power system. It is a necessary safety technical measure for parallel capacitors in substations, which can effectively prevent overvoltage and overcurrent that may endanger equipment safety when the capacitor bank is closed again due to the capacitor still carrying charge, and ensure the safety of maintenance personnel. This product comes with a secondary winding, which can be used for line monitoring, detection, and secondary protection.&lt;BR&gt;&lt;BR&gt;2¡¢ FDGRC-35kV series outdoor dry discharge coil model description&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191032719.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 161px; WIDTH: 373px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGRC-35kV series outdoor dry discharge coil model description&quot; src=&quot;/uploadfiles/200805/2008528191032719.jpg&quot; width=373 height=161&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Structure and performance characteristics&lt;BR&gt;a) The product adopts an imported epoxy resin vacuum casting structure, achieving oil-free operation, completely eliminating oil leakage, environmental pollution, and other issues&lt;BR&gt;Characteristics such as combustion.&lt;BR&gt;b) The product structure is simple and easy to install and use.&lt;BR&gt;c) The strengthened internal and external insulation provides the product with extremely high safety.&lt;BR&gt;d) The maintenance of the product is simple, just wipe off the surface dust during power outage maintenance.&lt;BR&gt;e) Using a special formula, the product is sturdy and reliable, with high mechanical strength, and can be used for a long time in various environments without cracking or breaking.&lt;BR&gt;&lt;BR&gt;4¡¢ Environmental conditions&lt;BR&gt;1. Environmental temperature: -40 to 55 &#176; C&lt;BR&gt;2. Altitude: not exceeding 2000m&lt;BR&gt;3. Seismic resistance level: Under the action of an earthquake intensity of 8 degrees, it will not be damaged.&lt;BR&gt;4. Installation location: No harmful gases, vapors, or conductive or explosive dust.&lt;BR&gt;&lt;BR&gt;5¡¢ Main technical performance indicators of FDGRC-35kV series outdoor dry discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191042494.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 234px; WIDTH: 450px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGRC-35kV series outdoor dry discharge coil technical parameters&quot; src=&quot;/uploadfiles/200805/2008528191042494.jpg&quot; width=450 height=234&gt;&lt;/A&gt;&lt;BR&gt;6¡¢ Connection method with capacitors&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191052178.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 285px; WIDTH: 442px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGRC-35kV series outdoor dry discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528191052178.jpg&quot; width=442 height=285&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;7¡¢ Outline installation dimension diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852819116561.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 285px; WIDTH: 470px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGRC-35kV series outdoor dry discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200852819116561.jpg&quot; width=470 height=285&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGRC-35kV series outdoor dry discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGR-35kV series dry discharge coil </title>
           <link>http://www.91way.com/info_en/3797.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:39</pubDate>
           <comments></comments>
           <description>&lt;A href=&quot;/uploadfiles/200805/200852819819552.jpg&quot; target=_blank&gt;&lt;/A&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200805/200852819740261.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 169px; WIDTH: 320px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR-35kV Series Dry Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/200852819740261.jpg&quot; width=320 height=169&gt;&lt;/A&gt;&lt;BR&gt;Purpose and Scope of Application&lt;BR&gt;&lt;BR&gt;After the parallel capacitor bank installed in the substation is out of operation, it must have a discharge device to release the internal charge. For the capacitor bank that implements automatic control switching, it is even more required to release its charge below the safe voltage within the specified time. Therefore, installing dedicated discharge coils is a necessary technical safety measure for parallel capacitors in substations.&lt;BR&gt;&lt;BR&gt;Considering the safety and reliability of parallel capacitor banks and their supporting equipment during operation, it is recommended to use a widely adopted single star wiring method for capacitor banks. The discharge coils are directly connected in parallel with each phase capacitor, and the secondary windings are connected in an open triangle shape, forming an unbalanced voltage protection circuit with the protection relay as internal protection for the capacitor. If any component inside a capacitor of any phase in the capacitor bank is damaged or faulty, it is required that the unbalanced voltage protection can detect and activate the switch to promptly disconnect the capacitor bank from the power grid. At this time, the discharge coil must have a sufficiently high accuracy level to ensure the implementation of this protection performance&lt;BR&gt;&lt;BR&gt;Structure and performance characteristics&lt;BR&gt;1. The product adopts an imported epoxy resin vacuum casting structure, achieving oil-free and completely eliminating the characteristics of oil leakage, environmental pollution, and flammability.&lt;BR&gt;2. The structure is simple and the installation and use are very convenient.&lt;BR&gt;3. The product maintenance is simple, just wipe off the surface dust during power outage maintenance.&lt;BR&gt;4. Strengthening the internal and external insulation makes the product highly safe.&lt;BR&gt;5. Using a special formula, the product is sturdy and reliable, with high mechanical strength, and can be used for a long time in various environments without cracking or breaking. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Main technical parameters of FDGR-35kV series dry discharge coil&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852819749536.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 336px; WIDTH: 548px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDGR-35kV series dry discharge coil&quot; src=&quot;/uploadfiles/200805/200852819749536.jpg&quot; width=548 height=336&gt;&lt;/A&gt;&lt;BR&gt;Connection method with capacitors&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085281981206.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 148px; WIDTH: 517px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR-35kV series dry discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/20085281981206.jpg&quot; width=517 height=148&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Ordering Notice&lt;BR&gt;1. Rated voltage and frequency of the system&lt;BR&gt;2. Voltage between the primary terminals of the discharge coil&lt;BR&gt;3. Capacity of the capacitor matched between the primary terminals of the discharge coil&lt;BR&gt;4. Secondary rated voltage, load and accuracy level of discharge coil&lt;BR&gt;&lt;BR&gt;FDGR-35kV series dry-type discharge coil appearance and installation dimension diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852819819552.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 327px; WIDTH: 515px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR-35kV series dry discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200852819819552.jpg&quot; width=515 height=327&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGR-35kV series dry discharge coil&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGZEX8 series discharge coil </title>
           <link>http://www.91way.com/info_en/3553.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:30</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008517115458167.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/uploadfiles/200805/2008517115458167.jpg&quot; width=530&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517115515553.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 414px; WIDTH: 591px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGZEX8 series discharge coil technical parameters&quot; src=&quot;/uploadfiles/200805/2008517115515553.jpg&quot; width=591 height=414&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517115532394.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 412px; WIDTH: 586px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGZEX8 series discharge coil appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008517115532394.jpg&quot; width=586 height=412&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;FDGZEX8 series discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGR Type 10KV Indoor Dry Discharge Coil </title>
           <link>http://www.91way.com/info_en/3459.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:22</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008514131331106.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 254px; WIDTH: 353px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR type 10KV indoor discharge coil model description&quot; src=&quot;/uploadfiles/200805/2008514131331106.jpg&quot; width=353 height=254&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008514131347231.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 614px; WIDTH: 637px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDGR type 10KV indoor discharge coil&quot; src=&quot;/uploadfiles/200805/2008514131347231.jpg&quot; width=637 height=614&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191228585.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 291px; WIDTH: 183px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR type 10KV indoor discharge coil wiring diagram&quot; src=&quot;/uploadfiles/200805/2008528191228585.jpg&quot; width=183 height=291&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;FDGR type 10KV indoor discharge coil&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Dry discharge coil]FDGR type 10KV outdoor discharge coil </title>
           <link>http://www.91way.com/info_en/3352.html</link>
           <author></author>
           <guid></guid>
           <category>Dry discharge coil</category>
           <pubDate>2026-6-20 21:56:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085128191558.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 238px; WIDTH: 385px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FDGR 10KV Outdoor Discharge Coil Model Description&quot; src=&quot;/uploadfiles/200805/20085128191558.jpg&quot; width=385 height=238&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851281917224.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 644px; WIDTH: 591px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of FDGR type 10KV outdoor discharge coil&quot; src=&quot;/uploadfiles/200805/200851281917224.jpg&quot; width=591 height=644&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008528191348697.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 288px; WIDTH: 541px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of FDGR type 10KV outdoor discharge coil&quot; src=&quot;/uploadfiles/200805/2008528191348697.gif&quot; width=541 height=288&gt;&lt;/A&gt;&lt;BR&gt;FDGR type 10KV outdoor discharge coil&lt;BR&gt;&lt;/P&gt;</description>