<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Indoor isolation switch</title>
       <link>http://www.91way.com</link>
       <description>Indoor isolation switch</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:15:52</pubDate>
       <item>
           <title>[Indoor isolation switch]GN24-12DC/400A-1250A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27660.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 15:13:25</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-12DC/400A-1250A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5D/630A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27662.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 15:12:53</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN27-40.5D/630A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN30-12D/630A-3150A Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27663.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:47:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN30-12D/630A-3150A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-40.5-630-2000A Single pole indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27668.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:47:19</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN2-40.5-630-2000A Single pole Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201908/20190817143359558.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 326px&quot; border=0 hspace=0 alt=&quot;GN2-40.5-630-2000A Single pole Indoor AC High Voltage Isolation Switch Dimensions&quot; src=&quot;/upload2019/201908/20190817143359558.jpg&quot; width=580 height=326&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5/2500A Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27661.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:54</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN27-40.5/2500A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12D/2000A-3150A Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27658.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN22-12D/2000A-3150A Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-12/630A Type Four Phase Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27659.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-12/630A Four Phase Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-24 Indoor AC High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/27657.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:46:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN22-24 Indoor AC High Voltage Isolation Switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12/400A-2000A series single pole indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27656.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:49</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN19-12/400A-2000A series single pole indoor AC high voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-24/5000A type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27655.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:41</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN10-24/5000A indoor high-voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-20/2000A-6300A series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/27654.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN10-20/2000A-6300A series indoor high-voltage isolation switch&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-S series 40.5kV indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/23518.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:24</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=103&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;System constant voltage&lt;/DIV&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;rated current&lt;/DIV&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;4s thermal stability current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Dynamic stable current&lt;/DIV&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;main circuit resistance&lt;/DIV&gt;
&lt;DIV align=center&gt;¦Ì ¦¸ (not greater than)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;Creepage distance ratio&lt;/DIV&gt;
&lt;DIV align=center&gt;cm/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;
&lt;DIV align=center&gt;time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108 colSpan=2&gt;
&lt;DIV align=center&gt;Lightning impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96 colSpan=2&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;To the ground, alternating with each other&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;To the ground, alternating with each other&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;DIV align=center&gt;fracture&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;DIV align=center&gt;one hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=48&gt;
&lt;DIV align=center&gt;two hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=60&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=36&gt;
&lt;DIV align=center&gt;one hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5£¨W£©/S2000-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=60&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=48&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;GN19-40.5£¨W£©/S3150-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN19-S series 40.5kV indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]C79-400/3.3 Isolation reversing switch </title>
           <link>http://www.91way.com/info_en/23409.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:15</pubDate>
           <comments></comments>
           <description>C79-400/3.3 isolation reversing switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]C79-700/3.3 Isolation reversing switch </title>
           <link>http://www.91way.com/info_en/23408.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:45:07</pubDate>
           <comments></comments>
           <description>C79-700/3.3 isolation reversing switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GNF38-32KV series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/19693.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GNF38-32KV series indoor isolation switch is designed and manufactured to meet the needs of the development of fixed high-voltage cabinets and ring main units towards compactness and miniaturization. It has a three station structure and a fully insulated bottom plate; And equipped with coaxial locking and a complete mechanical interlocking mechanism, the appearance is compact and small. It is the best optional switch for compact box type switchgear.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201207/20120723214432228.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 234px&quot; border=0 hspace=0 alt=&quot;GNF38-32KV series indoor high-voltage isolation switch model description&quot; src=&quot;/upload2012/201207/20120723214432228.jpg&quot; width=500 height=234&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;5¡¢ Main structural characteristics of GNF38-32KV series indoor high-voltage isolation switch&lt;BR&gt;Adopting the busbar through wall integral insulation bottom plate (APG process), the external insulation creepage distance can reach 24mm/kV, and the insulation performance is good.&lt;BR&gt;The single break point and three station structure ensure that the isolation switch cannot be grounded when closed and cannot be closed when grounded.&lt;BR&gt;Equipped with coaxial manual operation mechanism and position positioning device.&lt;BR&gt;&lt;BR&gt;6¡¢ Environmental conditions for the use of GNF38-32KV series indoor high-voltage isolating switches&lt;BR&gt;a. Surrounding air temperature: upper limit+40 ¡æ lower limit -25 ¡æ&lt;BR&gt;b. Altitude below 2000m&lt;BR&gt;c. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%&lt;BR&gt;d. The surrounding air should not be significantly polluted by corrosive or flammable gases, water vapor, etc&lt;BR&gt;e. No frequent severe vibrations&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201207/20120723214505303.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 927px&quot; border=0 hspace=0 alt=&quot;GNF38-32KV series indoor high-voltage isolation switch external dimensions and technical parameters&quot; src=&quot;/upload2012/201207/20120723214505303.jpg&quot; width=680 height=927&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201207/20120723214522602.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 843px&quot; border=0 hspace=0 alt=&quot;Installation diagram of GNF38-32KV series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201207/20120723214522602.jpg&quot; width=680 height=843&gt;&lt;/A&gt;&lt;BR&gt;GNF38-32KV series indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-10 series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/18997.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Description&lt;BR&gt;The GN2-12 series indoor AC high voltage isolation switch is a three-phase AC 50Hz high voltage switchgear used in power systems with a rated voltage of 10-35kV, for opening and closing circuits under voltage and no-load conditions. The isolation switch is equipped with CS6-2 manual operating mechanism.&lt;BR&gt;This series of isolation switches is a three-phase linkage type, consisting of a base frame, a shaft and linkage plate, post insulators, conductive switches, and static contacts. The shaft is mounted on the chassis, and a linkage plate is welded to the shaft. It is connected to the switch blade through a pull rod insulator (GN2-40.5T type epoxy glass cloth board insulation rod). The two ends of the rotating shaft extend from the chassis, and either end can be connected to the operating mechanism for opening and closing. This series of isolation switches can be installed horizontally, vertically, or diagonally.&lt;BR&gt;structure&lt;BR&gt;&lt;BR&gt;The GN2 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic Parameters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201205/20120509133349845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 517px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN2-10 series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201205/20120509133349845.jpg&quot; width=680 height=517&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201205/20120509133400454.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 267px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GN2-10 series indoor high-voltage isolation switch&quot; src=&quot;/upload2012/201205/20120509133400454.jpg&quot; width=680 height=267&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201205/20120509133417742.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 296px&quot; border=0 hspace=0 alt=&quot;GN2-10 series indoor high-voltage isolation switch external dimensions&quot; src=&quot;/upload2012/201205/20120509133417742.jpg&quot; width=680 height=296&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-35T Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/18996.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:42</pubDate>
           <comments></comments>
           <description>The GN2-10-35 series indoor high-voltage isolation switch is a three-phase AC 50Hz high-voltage switchgear used in power systems with a rated voltage of 10-35kV, for opening and closing circuits under no-load voltage conditions.&lt;BR&gt;Isolation switches with a rated current of 2000A and below are equipped with CS6-2T type manual operating mechanisms, while isolation switches with a rated current of 3000A are equipped with CS7 type manual operating mechanisms.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN2-35T indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;28%&quot;&gt;
&lt;DIV align=center&gt;Project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Data&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1000, 2000, 3000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;400, 600, 1000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80, 85, 100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;52, 64, 70&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40, 51, 70&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;14. 25, 27.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Installation dimensions of GN2-35T indoor high-voltage isolation switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201205/20120509132946802.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 346px&quot; border=0 hspace=0 alt=&quot;GN2-35T Indoor High Voltage Isolation Switch Appearance and Installation Dimensions&quot; src=&quot;/upload2012/201205/20120509132946802.jpg&quot; width=680 height=346&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5C/630A-2000A series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16403.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:34</pubDate>
           <comments></comments>
           <description>GN27-40.5C/630A-2000A series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10-10~20/4000A-9000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16402.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:26</pubDate>
           <comments></comments>
           <description>GN10-10-20/4000A-9000A indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/8000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16401.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:17</pubDate>
           <comments></comments>
           <description>GN22-12/8000A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/6300A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16400.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:08</pubDate>
           <comments></comments>
           <description>GN22-12/6300A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12C/2000A-4000A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16399.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:44:00</pubDate>
           <comments></comments>
           <description>GN22-12C/2000A-4000A Indoor High Voltage Isolation Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN22-12/2000A-5000A High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16398.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:51</pubDate>
           <comments></comments>
           <description>GN22-12/2000A-5000A High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-12/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16397.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:43</pubDate>
           <comments></comments>
           <description>GN16-12/400A-1250A Indoor High Voltage Isolation Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN15-12/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16396.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:34</pubDate>
           <comments></comments>
           <description>GN15-12/400A-1250A Indoor High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12CST/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16395.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:26</pubDate>
           <comments></comments>
           <description>GN19-12CST/400A-1250A indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12ST/400A-1250A Indoor high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/16394.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:18</pubDate>
           <comments></comments>
           <description>GN19-12ST/400A-1250A indoor isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN28-12 series indoor high-voltage combination isolation switch </title>
           <link>http://www.91way.com/info_en/8349.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:10</pubDate>
           <comments></comments>
           <description>The GN28-12 series indoor high-voltage combination isolation switch (hereinafter referred to as the isolation switch) is an indoor device with a rated voltage of 12kV three-phase AC 50Hz. Used for voltage and no-load division circuits. Suitable for XGN1 type box cabinet.&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;&lt;BR&gt;a. The ambient temperature is not higher than+40 ¡æ and not lower than -10 ¡æ&lt;BR&gt;b. The monthly average relative humidity should not exceed 90%&lt;BR&gt;c. Altitude not exceeding 1000m&lt;BR&gt;&lt;BR&gt;Structure and Characteristics&lt;BR&gt;GN28-12 type isolation switch is a combination type, consisting of two types: denominator knife isolation switch and line side isolation switch, mainly composed of contacts, contact knives, insulation components, and frames. The busbar isolation switch, line isolation switch, bypass isolation switch, and one set of grounding knife switches on each side of the switch are assembled on a frame, which not only reduces the volume, but also facilitates the installation of the entire set, eliminating the workload of operators hanging and dismantling grounding wires, as well as personal and equipment accidents caused by improper hanging and dismantling of grounding wires. The isolation switch is equipped with a rotating fully mechanical locking mechanism, which has the characteristics of easy and flexible operation, and reliable five prevention functions.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-12D type high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/8206.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:43:01</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview of GN24-1D High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;&lt;BR&gt;1000m altitude&lt;BR&gt;Surrounding air temperature: -30 ¡æ~+40 ¡æ; &amp;nbsp;&lt;BR&gt;Relative humidity of the surrounding environment: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;No severe vibration oscillation impact site; &amp;nbsp;&lt;BR&gt;A place without fire, explosion, corrosive metal, toxic gases that damage insulation, and conductive dust;&lt;BR&gt;&lt;BR&gt;GN24-1D High Voltage Isolation Switch Model and Meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911119408380.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;GN24-1D High Voltage Isolation Switch Model Description&quot; src=&quot;/upload2009/200911/200911119408380.gif&quot; width=500 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN24-1D High Voltage Isolation Switch Appearance and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;Figure 1, GN24-12 (D) type&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/2009111194037254.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 302px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194037254.gif&quot; width=577 height=302&gt;&lt;/A&gt;&lt;BR&gt;Figure 2, GN24-1D (C) type&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194058592.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 274px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194058592.gif&quot; width=577 height=274&gt;&lt;/A&gt;&lt;BR&gt;Figure 3: GN24-1D Type II&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194111828.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 577px; HEIGHT: 242px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194111828.gif&quot; width=577 height=242&gt;&lt;/A&gt;&lt;BR&gt;Figure 4: GN24-1D (C) Type II&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111194125311.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 576px; HEIGHT: 264px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 4 of GN24-1D high-voltage isolation switch&quot; src=&quot;/upload2009/200911/2009111194125311.gif&quot; width=576 height=264&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN24-1D High Voltage Isolation Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN38-10 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7192.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:53</pubDate>
           <comments></comments>
           <description>GN38 lower isolation switch&lt;BR&gt;&lt;BR&gt;Lower isolation coaxial right operation three workstations&lt;BR&gt;Manual integrated mechanism&lt;BR&gt;(Capable of grounding and closing)&lt;BR&gt;structural characteristics&lt;BR&gt;&lt;BR&gt;1. The isolation switch and grounding switch are integrated into one unit&lt;BR&gt;2. Grounding switch equipment related to short-circuit current capability&lt;BR&gt;3. Isolation and grounding switches have complete mechanical locking&lt;BR&gt;4. The outgoing terminal adopts side installation&lt;BR&gt;5. The height of the cable outlet is effectively guaranteed&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN38-10 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/7191.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:45</pubDate>
           <comments></comments>
           <description>GN38-10 series high voltage isolation switch&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The GN38-10 series high-voltage isolating switch adopts a busbar through wall insulation bottom plate, which completely isolates the switchgear busbar room from the circuit breaker room&lt;BR&gt;2. Equipped with a cross axis manual integrated operating mechanism, which not only ensures the mechanical performance of the isolation switch, but also reduces the operating height for convenient operation&lt;BR&gt;3. Single breakpoint three station structure ensures reliable switch operation&lt;BR&gt;GN38-10 series high-voltage isolating switch is equipped with a complete mechanical interlocking device&lt;BR&gt;&lt;BR&gt;Coaxial &quot;refers to the transmission main shaft and the operating mechanism shaft being the same shaft&lt;BR&gt;'Off axis' refers to the fact that the main transmission shaft and the operating mechanism shaft are two separate axes, with connecting rods or gears used for transmission in the middle&lt;BR&gt;Integrated mechanism &quot;refers to the combination of isolation switch and operating mechanism, whose external dimensions, installation method, and performance indicators are carefully calibrated before the product leaves the factory.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24 series isolating switch </title>
           <link>http://www.91way.com/info_en/6810.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:36</pubDate>
           <comments></comments>
           <description>GN24 series isolation switch&lt;BR&gt;&lt;BR&gt;GN24-10D/400A&lt;BR&gt;GN24-10DC/400A&lt;BR&gt;GN24-10D/630A&lt;BR&gt;GN24-10DC/630A&lt;BR&gt;GN24-10D/1000A&lt;BR&gt;GN24-10DC/1000A&lt;BR&gt;GN24-10D/1250A&lt;BR&gt;GN24-10DC/1250A&lt;BR&gt;&lt;BR&gt;The GN24-10D series indoor high-voltage isolating switch with grounding knife (hereinafter referred to as the isolating switch) is an indoor high-voltage switchgear with a rated voltage of 12KV or below and three-phase AC 50Hz. It is used for breaking and closing circuits in power systems with voltage and no load. The GN24-10D series isolating switch has three working positions: closing, opening, and grounding, and can be operated step by step. It has the anti misoperation performance of preventing live hanging grounding wires and closing with grounding. It is a necessary component to meet the requirements of &quot;three defenses&quot;. The grounding contact knife can be used for: when electrical equipment is powered off for maintenance, the semi grounding contact knife can be closed to create a network artificial short circuit, ensuring that maintenance personnel receive reliable &quot;ground potential&quot; protection.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;4S thermal stability current&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;GN24-12D&lt;/P&gt;
&lt;P align=center&gt;GN24-12DC&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;12kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;400A&lt;BR&gt;630A&lt;BR&gt;1000A&lt;BR&gt;1250A&lt;BR&gt;2000A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;P align=center&gt;20kA&lt;/P&gt;
&lt;P align=center&gt;31.5kA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]RH-B series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/4540.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:28</pubDate>
           <comments></comments>
           <description>Technical parameters of RH-B series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=110 align=middle&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=70 align=middle&gt;rated voltage&lt;/TD&gt;
&lt;TD rowSpan=2 width=103 align=middle&gt;rated current&lt;/TD&gt;
&lt;TD rowSpan=2 width=116 align=middle&gt;4S thermal stability current&lt;/TD&gt;
&lt;TD rowSpan=2 width=111 align=middle&gt;Dynamic stable voltage&lt;/TD&gt;
&lt;TD width=141 align=middle&gt;Dynamic stable voltage&lt;/TD&gt;
&lt;TD width=175 align=middle&gt;Impact withstand voltage&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=83&gt;relatively&lt;/TD&gt;
&lt;TD width=74&gt;Fracture gate&lt;/TD&gt;
&lt;TD width=101&gt;relatively&lt;/TD&gt;
&lt;TD width=90&gt;Fracture gate&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;RH-B&lt;/TD&gt;
&lt;TD width=70&gt;eleven&lt;/TD&gt;
&lt;TD width=103&gt;forty-four&lt;/TD&gt;
&lt;TD width=116&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=111&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=83&gt;seventy-five&lt;/TD&gt;
&lt;TD width=74&gt;ninety-five&lt;/TD&gt;
&lt;TD width=101&gt;38&amp;nbsp;&lt;/TD&gt;
&lt;TD width=90&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;RH-B&lt;/TD&gt;
&lt;TD width=70&gt;thirty-three&lt;/TD&gt;
&lt;TD width=103&gt;six hundred&lt;/TD&gt;
&lt;TD width=116&gt;twelve thousand and five hundred&lt;/TD&gt;
&lt;TD width=111&gt;thirty-one thousand and five hundred&lt;/TD&gt;
&lt;TD width=83&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD width=74&gt;one hundred and ninety-five&lt;/TD&gt;
&lt;TD width=101&gt;seventy&lt;/TD&gt;
&lt;TD width=90&gt;eighty&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RH-B series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN5 Indoor single-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/4486.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GN5 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=121&gt;model&lt;/TD&gt;
&lt;TD width=72&gt;Product Code&lt;/TD&gt;
&lt;TD width=87&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD width=116&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD width=81&gt;Rated current A&lt;/TD&gt;
&lt;TD width=137&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD width=122&gt;5-second thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD width=64&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-two&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;twenty-five point five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-three&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;four point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six point nine&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;twenty-five point five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;six point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-seven&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty-two&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/1250&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and forty-one&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;seventeen&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Appearance and installation dimensions of GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=93&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Factory code&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD rowSpan=2 width=93&gt;Rated current A&lt;/TD&gt;
&lt;TD colSpan=4&gt;Main dimensions (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=93&gt;H&lt;/TD&gt;
&lt;TD width=93&gt;h&lt;/TD&gt;
&lt;TD width=93&gt;h1&lt;/TD&gt;
&lt;TD width=123&gt;t&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-two&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-three&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-6/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-four&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;four hundred and thirty&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-one&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/200&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and forty&lt;/TD&gt;
&lt;TD&gt;two hundred and forty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-six&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN5-10/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and thirty-seven&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200810/2008101133349119.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 560px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Diagram of GN5 Indoor Single phase High voltage Isolation Switch&quot; src=&quot;/uploadfiles/200810/2008101133349119.jpg&quot; width=500 height=560&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200810/200810113344777.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 392px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN5 indoor single-phase high voltage isolation switch&quot; src=&quot;/uploadfiles/200810/200810113344777.jpg&quot; width=500 height=392&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN5 indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2-40.5(W) type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/4186.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/2008723163146845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 356px; HEIGHT: 677px&quot; border=0 hspace=0 alt=&quot;GN2-40.5 (W) Indoor High Voltage Isolation Switch Description&quot; src=&quot;/uploadfiles/200807/2008723163146845.jpg&quot; width=356 height=677&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200807/2008723163215529.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=&quot;GN2-40.5 (W) Indoor High Voltage Isolation Switch Outline and Installation Dimensional Drawing&quot; src=&quot;/uploadfiles/200807/2008723163215529.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated current/A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Dynamic stability current (peak value)/kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Thermal stability current (effective value)/kA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6s&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-12/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-12/3000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-20/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/400 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;GN2-40.5/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/2000 (all operating conditions)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630-¢ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/630-¢ò&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/1250-¢ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN2-40.5/1250-¢ò&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN2-40.5 (W) type indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GNF38-12/630A type indoor ring main unit isolation switch </title>
           <link>http://www.91way.com/info_en/2665.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:42:03</pubDate>
           <comments></comments>
           <description>The LZFW-35GY current transformer adopts our company's unique technology, which integrates outdoor epoxy resin and silicone rubber into a composite insulation form. It is not a general form of silicone rubber umbrella sheet bonding, and the overall product is firm. It belongs to the new generation of outdoor products. Widely used in outdoor or indoor power systems with a rated frequency of 50 Hz and a rated voltage of 35 kV or below, it is also used for metering, measurement, and monitoring protection.&lt;BR&gt;&lt;BR&gt;Characteristics of GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;1. This product is made of outdoor epoxy resin, and the non winding part is coated with silicone rubber and fully vacuum cast. It is a fully enclosed insulation and pillar structure. The product fully combines the advantages of good processability and strong heat dissipation performance of outdoor epoxy resin with the strong UV resistance, good water addition, anti fog flash and anti pollution flash ability of silicone rubber, while complementing each other's shortcomings, to achieve good internal and external insulation performance. The product has anti fog and anti humidity, anti pollution flash, excellent resistance to cold and hot shock, good environmental adaptability, strong hydrophobicity and anti UV linear ability, anti-aging and arc resistance, long service life, and can fully meet outdoor use conditions.&lt;BR&gt;2. The product adopts a ring-shaped ultra microcrystalline alloy iron core and imported high-quality silicon steel sheet coil iron core. Has high metrological accuracy, stable error, and low instrument security factor; Stable protection level performance and high accuracy limit coefficient. The transformer has the characteristics of low power consumption and minimal residual magnetism.&lt;BR&gt;3. According to user requirements, production can be done in various ratios and multi-level combinations. Beneficial for power station expansion and effectively saving investment.&lt;BR&gt;4. The product can be installed independently or used in conjunction with outdoor circuit breakers and other outdoor equipment. It has the characteristics of easy installation and replacement, and maintenance free use.&lt;BR&gt;&lt;BR&gt;Usage conditions for GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;Fully meet the high-altitude outdoor product usage conditions specified in IEC185-87 and GB1208-1997, as well as the requirements of Level II pollution prevention level.&lt;BR&gt;&lt;BR&gt;Basic technical parameters of GNF38-12/630A indoor ring main unit isolation switch&lt;BR&gt;1. Rated voltage 35 kV&lt;BR&gt;2. Rated altitude ¡Ü 4000 meters&lt;BR&gt;3. Rated insulation level 40.5/95/185 kV&lt;BR&gt;4. Rated primary current 20-3000 A&lt;BR&gt;5. Rated secondary current 5A or 1A&lt;BR&gt;6. Partial discharge capacity in accordance with GB1208-1997 standard, apparent discharge capacity ¡Ü 20 pC&lt;BR&gt;7. Dynamic thermal stability current: 1 second thermal current=110 I1n; Dynamic stability current=2.5 Ith&lt;BR&gt;8. Rated primary current, level combination, and corresponding rated output relationship Rated primary current&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Rated primary current&lt;BR&gt;£¨A£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;Accurate level combination&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Rated secondary output (VA)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2£¨0.2S£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P10&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6&gt;
&lt;P align=center&gt;20~600&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2£¨0.2S£©/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.5/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;10P/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;---&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2 (or 0.2S)/0.5/10P&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.2 (or 0.2S)/10P/10P&lt;/P&gt;&lt;/TD&gt;
&lt;P&gt;Overview&lt;BR&gt;&lt;BR&gt;The GNF38-12KV series indoor ring main unit isolation switch is designed and manufactured to meet the needs of the development of fixed high-voltage cabinets and ring main units towards compactness and miniaturization. It has a three station structure and a fully insulated bottom plate; And equipped with coaxial locking and a complete mechanical interlocking mechanism, the appearance is compact and small. It is the best optional switch for compact box type switchgear.&lt;BR&gt;&lt;BR&gt;Switch model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385648411.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 530px; HEIGHT: 176px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A type indoor ring main unit isolation switch model description&quot; src=&quot;/uploadfiles/200710/2007101385648411.jpg&quot; width=530 height=176&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Reference standards&lt;BR&gt;&lt;BR&gt;GB1985-1989 AC High Voltage Disconnectors and Grounding Switches&lt;BR&gt;IEC129-84 AC isolating switches and grounding switches&lt;BR&gt;&lt;BR&gt;Normal usage conditions&lt;BR&gt;&lt;BR&gt;a. Surrounding air temperature: upper limit+40 ¡æ lower limit -25 ¡æ&lt;BR&gt;b. Altitude not exceeding 2000m&lt;BR&gt;c. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%&lt;BR&gt;d. The surrounding air should not be significantly polluted by corrosive or flammable gases, water vapor, etc&lt;BR&gt;e. No frequent severe vibrations&lt;BR&gt;&lt;BR&gt;Main technology of GNF38-12/630A indoor ring main unit isolation switch
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385715434.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 347px&quot; border=0 hspace=0 alt=&quot;Technical parameter table of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385715434.jpg&quot; width=550 height=347&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Main structural features&lt;BR&gt;&lt;BR&gt;Adopting busbar through wall integral insulation bottom plate (APG process), the external insulation creepage distance can reach 24MM/kV, and the insulation performance is good.&lt;BR&gt;The single break point and three station structure ensure that the isolation switch cannot be grounded when closed and cannot be closed when grounded.&lt;BR&gt;Equipped with coaxial manual operation mechanism and position positioning device.&lt;BR&gt;&lt;BR&gt;Installation and debugging&lt;BR&gt;&lt;BR&gt;After opening the box, the product should be checked for any damage or rust, the product nameplate and certificate of conformity should match the purchase order, and the packing list should match the actual product and be in good condition.&lt;BR&gt;Clean the surface of dust and dirt.&lt;BR&gt;Check if the screws at the main connecting parts of the switch are loose. If so, tighten and adjust them.&lt;BR&gt;Apply industrial Vaseline oil to the mechanical friction parts.&lt;BR&gt;According to the position of the high-voltage cabinet and the ring main unit, installation is required, and attention should be paid to the insulation distance between the live part and the ground when the switch is opened, which should be greater than 125cm.&lt;BR&gt;After the switch is installed, it should be operated without load 3-5 times, and the opening, closing, and grounding signs should be checked to ensure that they match the corresponding operation. There should be no abnormal phenomena such as jamming during operation.&lt;BR&gt;The pressure of the contact spring between the moving and stationary contacts has been adjusted before leaving the factory, and users do not need to adjust it again.&lt;BR&gt;The connection between the switch and the busbar must have good contact and be securely fixed.&lt;BR&gt;&lt;BR&gt;Usage and Maintenance&lt;BR&gt;&lt;BR&gt;The opening, closing, and grounding positions of the switch are determined and locked, and the mechanical interlocking action is performed. The identification of each position is completed by the operating mechanism.&lt;BR&gt;Before operation, it is necessary to check whether the mechanism is safe and reliable.&lt;BR&gt;First, turn the wrench on the panel towards the operating axis, then release it. Insert the handle and rotate it in the direction indicated by the arrow on the panel. Once the operation is in place, the wrench on the panel will automatically return to its original position. Repeat the above steps when operating again.&lt;BR&gt;When the operating mechanism leaves the factory, its internal sliding parts are coated with lubricating grease. If the user finds any obstruction during operation, they can open the front cover and apply lubricating grease to the sliding parts.&lt;BR&gt;The maintenance of the switch is not carried out with electricity, and it is not allowed to pull the switch with load.&lt;BR&gt;During maintenance, the fixing screws of the insulation base and insulation support, the spring compression of the moving contact knife, the shaft retaining ring on the connecting pin between the insulation rod and the insulation crank arm, and the opening on the connecting pin between the insulation rod and the moving contact knife should be carefully inspected. If there are any abnormalities, they should be adjusted and maintained in a timely manner.&lt;BR&gt;When the contact positions of the static contact and the moving contact blade are found to be burnt or blackened during maintenance, it is not allowed to use a file to lower the contact points. Only sandpaper can be used to polish them, and then industrial Vaseline grease can be applied.&lt;BR&gt;During maintenance, attention should be paid to observing the deformation of the clamping spring of the moving contact blade. If there is any deformation, it should be adjusted or replaced in a timely manner.&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385747430.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 396px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A type indoor ring main unit isolation switch appearance and installation dimension diagram&quot; src=&quot;/uploadfiles/200710/2007101385747430.jpg&quot; width=560 height=396&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/200710138584177.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 311px; HEIGHT: 441px&quot; border=0 hspace=0 alt=&quot;Installation method of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/200710138584177.jpg&quot; width=311 height=441&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Installation method&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385921404.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 355px&quot; border=0 hspace=0 alt=&quot;Installation diagram of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385921404.jpg&quot; width=560 height=355&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385935871.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 340px&quot; border=0 hspace=0 alt=&quot;GNF38-12/630A indoor ring main unit isolation switch left and right operation diagram&quot; src=&quot;/uploadfiles/200710/2007101385935871.jpg&quot; width=560 height=340&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101385947853.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 450px; HEIGHT: 322px&quot; border=0 hspace=0 alt=&quot;Front view of GNF38-12/630A indoor ring main unit isolation switch&quot; src=&quot;/uploadfiles/200710/2007101385947853.jpg&quot; width=450 height=322&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GNF38-12/630A type indoor ring main unit isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/P&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]DGN-12 type indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/1629.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:55</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=257&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;unit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=145&gt;
&lt;DIV align=center&gt;parameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;630, 1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20. 31.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50, 80&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time continuous current&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Rated insulation level 1-minute power frequency withstand voltage&lt;BR&gt;Lightning impulse withstand voltage (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;BR&gt;kV&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-two&lt;BR&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DGN-12 indoor high-voltage isolation switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-35 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1551.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:46</pubDate>
           <comments></comments>
           <description>GN19-35 series high voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]DGN-12D series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1230.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:38</pubDate>
           <comments></comments>
           <description>DGN-12D series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN36-12 series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1229.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:30</pubDate>
           <comments></comments>
           <description>GN36-12 series high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN24-10(C) series high-voltage isolating switch </title>
           <link>http://www.91way.com/info_en/1228.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN24-10 (C) series high-voltage isolating switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075811771.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 643px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN24-10 (C) series high-voltage isolating switch&quot; src=&quot;/upload2013/201303/20130317075811771.jpg&quot; width=643 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075820799.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 638px&quot; border=0 hspace=0 alt=&quot;GN24-10 (C) series high-voltage isolation switch external dimensions&quot; src=&quot;/upload2013/201303/20130317075820799.jpg&quot; width=680 height=638&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130317075829765.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 643px; HEIGHT: 638px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GN24-10 (C) series high-voltage isolation switch&quot; src=&quot;/upload2013/201303/20130317075829765.jpg&quot; width=643 height=638&gt;&lt;/A&gt;&lt;BR&gt;GN24-10 (C) series high-voltage isolating switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-35/2000 High voltage and high current isolation switch </title>
           <link>http://www.91way.com/info_en/1227.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:13</pubDate>
           <comments></comments>
           <description>GN16-35/2000 High Voltage and High Current Isolation Switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19 Indoor three-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/872.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:41:04</pubDate>
           <comments></comments>
           <description>The GN19-10 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;The GN19-10C indoor three-phase high voltage isolation switch consists of a base, a pair of ceramic insulators, a ceramic sleeve, an operating ceramic insulator, and a conductive part.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KV (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;10s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;weight&lt;BR&gt;kg&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-seven&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C2/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10/1000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-10C1/1000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN19 indoor three-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10 Type Indoor Single (Three) Phase High Voltage Isolation Switch </title>
           <link>http://www.91way.com/info_en/871.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:56</pubDate>
           <comments></comments>
           <description>The GN10 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts. Can be used for single-phase or three-phase connection. Can be operated with manual or electric mechanisms.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot;&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;7%&quot;&gt;rated&lt;BR&gt;Voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;It's a senior engineer&lt;BR&gt;Operating voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;8%&quot;&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot;&gt;Dynamic stability current KA&lt;BR&gt;(Peak value)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;10s thermal stability current KA&lt;BR&gt;(Effective value)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Main dimensions (mm)&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;14%&quot; align=middle&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;H&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;h&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/3000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;70-5&lt;/TD&gt;
&lt;TD&gt;six hundred and forty-five&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty-five&lt;/TD&gt;
&lt;TD&gt;¡«54&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/4000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;85-5&lt;/TD&gt;
&lt;TD&gt;seven hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty&lt;/TD&gt;
&lt;TD&gt;¡«60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/5000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;five thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«135&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-10/6000&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;six thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«145&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/3000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;70-5&lt;/TD&gt;
&lt;TD&gt;eight hundred and ten&lt;/TD&gt;
&lt;TD&gt;four hundred and sixty&lt;/TD&gt;
&lt;TD&gt;¡«77&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/4000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;four thousand&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;85-5&lt;/TD&gt;
&lt;TD&gt;eight hundred and sixty&lt;/TD&gt;
&lt;TD&gt;four hundred and ninety-five&lt;/TD&gt;
&lt;TD&gt;¡«87&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/5000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«150&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/6000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;six thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«160&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/8000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;eight thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«180&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN10-20/10000&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;ten thousand&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-four&lt;/TD&gt;
&lt;TD&gt;74-10&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;
&lt;TD&gt;¡«180&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN10 indoor single-phase and three-phase high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN6,GN8 Indoor three-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/870.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:48</pubDate>
           <comments></comments>
           <description>The GN6-6 and 10T indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;GN8-6, 10T - ¢ñ, ¢ò type indoor three-phase high voltage isolation switches consist of a base, pillar porcelain insulators, porcelain sleeves, operating insulators, and conductive parts.&lt;BR&gt;GN8-6, 10T-III indoor three-phase high voltage isolation switch consists of a base, porcelain bushing, operating porcelain insulator, and conductive part&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;5-second thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/200, GN8-6T/200- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/200, GN8-6T/400- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-6T/630, GN8-6T/630- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six point nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/200, GN8-10T/200- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/400, GN8-10T/400- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/630, GN8-10T/630- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-10T/1250, GN8-10T/1250- I, II, III&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN6-35T-1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200910/2009102223837819.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 592px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN6 and GN8 indoor three-phase high voltage isolation switches&quot; src=&quot;/upload2009/200910/2009102223837819.jpg&quot; width=350 height=592&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN1 Indoor single-phase high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/869.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:39</pubDate>
           <comments></comments>
           <description>The GN1 indoor single-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;P align=center&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;10s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;weight&lt;BR&gt;kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-10/2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-20/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-35/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN1-35/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;Appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200810/2008101133254717.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Dimensional Drawing of GN1 Indoor Single phase High voltage Isolation Switch&quot; src=&quot;/uploadfiles/200810/2008101133254717.jpg&quot; width=680 height=220&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN1 type indoor single-phase high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]Indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/835.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:31</pubDate>
           <comments></comments>
           <description>GN22-12 (C) Indoor AC High Voltage Isolation Switch Model and Its Meaning&lt;BR&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude: not exceeding 1000m;&lt;BR&gt;+Surrounding air temperature: -30 ¡æ to+40 ¡æ;&lt;BR&gt;+Relative humidity of the surrounding environment: daily average not exceeding 95%; Monthly average not exceeding 90%;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+Safe place: No fire, flammable, explosive, severely polluted, chemically corroded, or violently vibrating places.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN22-12 (C) indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;1600~2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;2500~3150&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-circuit withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated peak withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=left&gt;Rated short-time duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;
&lt;DIV align=left&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Inter pole, pole to ground 42 fracture 49&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Lightning impulse withstand voltage (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Inter pole, pole to ground 75 fracture 85&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensions (The following image can be clicked to enlarge):&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/20061030213842323.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 166px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 1&quot; src=&quot;/uploadfiles/200610/20061030213842323.jpg&quot; width=245 height=166&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021394155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 166px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 2&quot; src=&quot;/uploadfiles/200610/2006103021394155.jpg&quot; width=245 height=166&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;Figure 1: Dimensions of GN22-12 Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;29%&quot;&gt;
&lt;DIV align=center&gt;Model number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;GN22-12/1600-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;three hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;five hundred and twenty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;GN22-12/2500-3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;three hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;five hundred and thirty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;four hundred and ninety-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021418587.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 196px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 3&quot; src=&quot;/uploadfiles/200610/2006103021418587.jpg&quot; width=500 height=196&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021423818.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 165px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 4&quot; src=&quot;/uploadfiles/200610/2006103021423818.jpg&quot; width=245 height=165&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Figure 2: Dimensions of GN22-12C Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061030214346155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 340px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Outline and Installation Dimensional Drawing 5&quot; src=&quot;/uploadfiles/200610/20061030214346155.jpg&quot; width=340 height=170&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200610/2006103021444701.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 340px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;GN22-12 (C) Indoor AC High Voltage Isolation Switch Appearance and Installation Dimensional Drawing 6&quot; src=&quot;/uploadfiles/200610/2006103021444701.jpg&quot; width=340 height=170&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN22-12C/1600-2000 High Voltage Isolation Switch Terminal Diagram GN22-12C/2500-3150 High Voltage Isolation Switch Terminal Diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN22-12C/1600-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN22-12C/2500-3150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-seven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN22-12 (C) Indoor AC High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN16-7.2/400-20 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/830.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:23</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (KG)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN16-7.2/400-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20/2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;530*360*360&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GN16-7.2/400-20 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN8-3.6 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/829.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:14</pubDate>
           <comments></comments>
           <description>GN8-3.6 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak value&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Equipped with a handle&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR bgColor=#ffffff&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN8-3.6/S400-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;480*248*170&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;370*175&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030193214485.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN8-3.6 high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061030193214485.gif&quot; width=680 height=500&gt;&lt;/A&gt;&lt;BR&gt;GN8-3.6 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN10 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/828.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:40:06</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030192853284.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;GN10 High Voltage Isolation Switch Outline and Installation Dimensional Drawing&quot; src=&quot;/uploadfiles/200610/20061030192853284.gif&quot; width=680 height=580&gt;&lt;/A&gt;&lt;BR&gt;GN10 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN9-3.6/S200-5 High voltage isolation switch </title>
           <link>http://www.91way.com/info_en/827.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;GN9-3.6/S200-5 indoor one-way isolation switch, suitable for 3600V level electrical control cabinets, plays the role of isolating circuits, mainly used in the fields of petroleum, chemical industry, etc.&lt;BR&gt;&lt;BR&gt;SGN9-3.6/S200-5 indoor bidirectional isolation switch is used in 3600V electrical control cabinets to isolate circuits, ground circuits, or phase change circuits.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200610/20061030192442363.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 600px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of GN9-3.6/S200-5 high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061030192442363.gif&quot; width=680 height=600&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;GN9-3.6/S200-5 High Voltage Isolation Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;rated&lt;BR&gt;current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak value&lt;BR&gt;Withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short circuit&lt;BR&gt;duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Equipped with a handle&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN9-3.6/S200-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;320*224*175&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;184*100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HD12-200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;SGN9-3.6/S200-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300*260*175&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;230*100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HD13-200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN25-10 type high current and high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/767.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:49</pubDate>
           <comments></comments>
           <description>GN25-10/2000¡¢ The 3000 type household three high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN25-10 high current and high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=113&gt;model&lt;/TD&gt;
&lt;TD width=72&gt;Product Code&lt;/TD&gt;
&lt;TD width=92&gt;rated voltage&lt;/TD&gt;
&lt;TD width=130&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD width=122&gt;Rated current A&lt;/TD&gt;
&lt;TD width=84&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD width=116&gt;5-second thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD width=93&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN25-10T/2000&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand one hundred and fifteen&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;seventy-four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN25-10T/3000&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand one hundred and nineteen&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;three thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820023910.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 440px&quot; border=0 hspace=0 alt=&quot;Outline and Installation Dimensional Drawing of GN25-10 High Current High Voltage Isolation Switch&quot; src=&quot;/uploadfiles/200610/2006102820023910.jpg&quot; width=680 height=440&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;GN25-10 high current and high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN27-40.5 series indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/444.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:41</pubDate>
           <comments></comments>
           <description>GN27-40.5 indoor high-voltage isolation switch is a new type of product. Suitable for rated voltage&lt;BR&gt;40.5V£¬ In a 50Hz AC power system, it is designed and produced as a replacement for old products to open and close circuits with voltage and no load. Can be paired with high-voltage switchgear or used independently. Equipped with CS6-2 operating mechanism. All adopt reinforced insulation design, which can meet the requirements for use in Class II polluted areas. Product features:&lt;BR&gt;&lt;BR&gt;Design scientifically, reasonably, and structurally innovative; &amp;nbsp;&lt;BR&gt;Multi contact, rotating contact, good self-cleaning ability, and improved heat dissipation capability; &amp;nbsp;&lt;BR&gt;The contact point is within two surfaces, with low operating torque, high contact pressure, and easy adjustment; &amp;nbsp;&lt;BR&gt;Adopting a large climbing distance to enhance insulation capability and withstand voltage to meet the highest requirements; &amp;nbsp;&lt;BR&gt;Installing bearings on the shaft increases its service life and makes it easy to operate.&lt;BR&gt;&lt;BR&gt;Technical parameters of GN27-40.5 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=68&gt;
&lt;DIV align=center&gt;Rated voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;DIV align=center&gt;4s rated short-time withstand current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=76&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;DIV align=center&gt;Lightning impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;95/118&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;185/125&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061121101213943.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 700px&quot; border=0 hspace=0 alt=&quot;GN27-40.5 Series Indoor High Voltage Isolation Switch Selection Instructions&quot; src=&quot;/uploadfiles/200611/20061121101213943.jpg&quot; width=680 height=700&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061121101243194.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200611/20061121101243194.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 129px&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center height=129&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=13 width=109&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;Rated voltage KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Maximum working voltage KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Dynamic stability current KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;Thermal stability current KA-S&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;16-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;25-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;36-10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35-C1¡¢C2/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;16-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;CN27-35C1¡¢C2/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;25-6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=109&gt;
&lt;DIV align=center&gt;GN27-35C1¡¢C2/1600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;forty point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;DIV align=center&gt;36-10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085272117509.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 266px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/20085272117509.gif&quot; width=600 height=266&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35/630¡¢ Outline and installation diagram of 1250 and 1600 isolation switches&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200852721133787.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 259px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/200852721133787.gif&quot; width=600 height=259&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35C2/630¡¢ Appearance and installation diagram of 1250 and 1600 isolation switches&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852721145401.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 263px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN27-40.5 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200805/200852721145401.gif&quot; width=600 height=263&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;&lt;BR&gt;GN27-35C1-630¡¢ Appearance and installation diagram of 1250 and 1600 isolation switches&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;Ordering Instructions&lt;BR&gt;When placing an order, please specify the product model, rated voltage, rated current, and if installing composite insulators with H&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN30-12(D) Rotating indoor high-voltage isolation switch </title>
           <link>http://www.91way.com/info_en/351.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:32</pubDate>
           <comments></comments>
           <description>&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 309px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200610/20061024233622526.jpg&quot; width=500 height=309&gt;&lt;/DIV&gt;&lt;BR&gt;Environmental conditions for use:&lt;BR&gt;+Altitude: 1000-3000m;&lt;BR&gt;+Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ;&lt;BR&gt;+Relative humidity of the surrounding environment: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;+The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;+Places without severe dust, chemical corrosion, and explosive substances;&lt;BR&gt;+No places with frequent and severe vibrations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of GN30-12 (D) rotary indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Maximum operating voltage&lt;BR&gt;kv&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;rated current&lt;BR&gt;A&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Dynamic stable current&lt;BR&gt;KA (peak value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;4s thermal stability current&lt;BR&gt;KA (effective value)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/100-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/2000-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/2500-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10/3150-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/2000-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/2500-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN30-10D/3150-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Appearance and Installation Dimensions&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%&quot; border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 1&quot; src=&quot;/uploadfiles/200610/20061024233635863.jpg&quot; width=245 height=151&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 137px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 2&quot; src=&quot;/uploadfiles/200610/20061024233644318.jpg&quot; width=137 height=151&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 114px; HEIGHT: 151px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN30-12 (D) rotary indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/20061024233652616.jpg&quot; width=114 height=151&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 1 Outline drawing of GN30-12/630, 1000 indoor AC high voltage isolation switch 630A wiring terminal diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 4&quot; src=&quot;/uploadfiles/200610/2006102423370570.jpg&quot; width=245 height=145&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 131px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 5&quot; src=&quot;/uploadfiles/200610/2006102423378446.jpg&quot; width=131 height=145&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 114px; HEIGHT: 145px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 6&quot; src=&quot;/uploadfiles/200610/20061024233719478.jpg&quot; width=114 height=145&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 2: Outline drawing of GN30-12/630, 1000 indoor AC high voltage isolation switch 1000A wiring terminal diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 168px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 7&quot; src=&quot;/uploadfiles/200610/20061024233727407.jpg&quot; width=245 height=168&gt;&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 138px; HEIGHT: 168px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 8&quot; src=&quot;/uploadfiles/200610/20061024233733914.jpg&quot; width=138 height=168&gt;&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Figure 3 Outline drawing of GN30-12D/630, 1000 indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;CN30-12&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;DIV align=center&gt;CN30-12D&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;630A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;630A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;1000A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«560&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«315&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«580&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«332&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«550&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«610&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«575&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«615&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡«245&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 144px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 9&quot; src=&quot;/uploadfiles/200610/20061024233741593.jpg&quot; width=245 height=144&gt;&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 125px; HEIGHT: 144px&quot; border=0 hspace=0 alt=&quot;GN30-12 (D) Rotary Indoor High Voltage Isolation Switch Installation Dimensional Drawing 10&quot; src=&quot;/uploadfiles/200610/20061024233748742.jpg&quot; width=125 height=144&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Figure 4 Outline drawing of GN30-12/1250 indoor AC high voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN2 series indoor high-voltage isolation switch GN2-10/2000 GN2-10/3000</title>
           <link>http://www.91way.com/info_en/335.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:23</pubDate>
           <comments></comments>
           <description>structure&lt;BR&gt;The GN2 indoor three-phase high voltage isolation switch consists of a base, pillar porcelain insulators, operating porcelain insulators, and conductive parts. Among them: GN2-35/630-I, II; The 1250-I and II type indoor three-phase high voltage isolation switches consist of a base, pillar porcelain insulators, porcelain sleeves, operating porcelain insulators, and conductive parts.&lt;BR&gt;&lt;BR&gt;Basic parameters of GN2 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 400px&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center height=400&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=170&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=69&gt;Product Code&lt;/TD&gt;
&lt;TD rowSpan=2 width=86&gt;Rated voltage kV&lt;/TD&gt;
&lt;TD rowSpan=2 width=119&gt;Maximum working voltage KV&lt;/TD&gt;
&lt;TD rowSpan=2 width=80&gt;Rated current A&lt;/TD&gt;
&lt;TD rowSpan=2 width=161&gt;Dynamic stability current KA (peak value)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Thermal stability current KA (effective value)&lt;/TD&gt;
&lt;TD rowSpan=2 width=59&gt;Weight kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90 align=middle&gt;10s&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;6s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-one&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/3000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-two&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;eleven point five&lt;/TD&gt;
&lt;TD&gt;three thousand&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty-seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-20/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;twenty-three&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-seven&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and two&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and fourteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-eight&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and three&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;fourteen&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and nineteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and sixty-four&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty-five&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/2000 (all operating conditions)&lt;/TD&gt;
&lt;TD&gt;seventy-one thousand four hundred and four&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;two thousand&lt;/TD&gt;
&lt;TD&gt;eighty-five&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;two hundred and six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630-¢ñ&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-five&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixteen&lt;/TD&gt;
&lt;TD&gt;two hundred and twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630-¢ò&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-six&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixteen&lt;/TD&gt;
&lt;TD&gt;two hundred and twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/1250-¢ñ&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-seven&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty-one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/1250-¢ò&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and ninety-eight&lt;/TD&gt;
&lt;TD&gt;thirty-five&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty-one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;GN2 series indoor high-voltage isolation switch appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 200px&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center height=200&gt;
&lt;TBODY&gt;
&lt;TR align=middle width=&quot;None&quot;&gt;
&lt;TD rowSpan=2 width=101&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=81&gt;Product Code&lt;/TD&gt;
&lt;TD colSpan=8&gt;Main dimensions (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=46 align=middle&gt;L&lt;/TD&gt;
&lt;TD width=44 align=middle&gt;L1&lt;/TD&gt;
&lt;TD width=44 align=middle&gt;H&lt;/TD&gt;
&lt;TD width=66 align=middle&gt;h&lt;/TD&gt;
&lt;TD width=66 align=middle&gt;A&lt;/TD&gt;
&lt;TD width=59 align=middle&gt;A1&lt;/TD&gt;
&lt;TD width=61 align=middle&gt;A1&lt;/TD&gt;
&lt;TD width=49 align=middle&gt;B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD height=22&gt;GN2-10/2000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-one&lt;/TD&gt;
&lt;TD&gt;one thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty-two&lt;/TD&gt;
&lt;TD&gt;three hundred and twenty-seven&lt;/TD&gt;
&lt;TD&gt;nine hundred and ten&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;three hundred and sixteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-10/3000&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-two&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and forty&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;six hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;three hundred and sixty&lt;/TD&gt;
&lt;TD&gt;nine hundred and sixty-six&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;four hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-20/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-five&lt;/TD&gt;
&lt;TD&gt;one thousand one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;nine hundred and eight&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/400&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-seven&lt;/TD&gt;
&lt;TD&gt;one thousand five hundred and thirty&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty&lt;/TD&gt;
&lt;TD&gt;nine hundred and fifty&lt;/TD&gt;
&lt;TD&gt;five hundred and twenty&lt;/TD&gt;
&lt;TD&gt;one thousand and one hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;GN2-35/630&lt;/TD&gt;
&lt;TD&gt;seven thousand one hundred and fifty-eight&lt;/TD&gt;
&lt;TD&gt;one thousand five hundred and thirty&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty&lt;/TD&gt;
&lt;TD&gt;nine hundred and sixty&lt;/TD&gt;
&lt;TD&gt;five hundred and thirty-five&lt;/TD&gt;
&lt;TD&gt;one thousand and one hundred&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty-five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820656299.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 1 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820656299.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820716290.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 280px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 2 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820716290.jpg&quot; width=680 height=280&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820732431.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 3 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820732431.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006102820742454.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram 4 of GN2 series indoor high-voltage isolation switch&quot; src=&quot;/uploadfiles/200610/2006102820742454.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GN2 series indoor high-voltage isolation switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Indoor isolation switch]GN19-12(C) series indoor AC high voltage isolation switch </title>
           <link>http://www.91way.com/info_en/193.html</link>
           <author></author>
           <guid></guid>
           <category>Indoor isolation switch</category>
           <pubDate>2026-6-19 14:39:15</pubDate>
           <comments></comments>
           <description>The GN19-12 (C) series indoor AC high voltage isolation switch is suitable for use in AC 50Hz, rated voltage 12kV and below power systems. It is equipped with a manual operating mechanism and is used as a switching device when there is voltage but no load.&lt;BR&gt;&lt;BR&gt;The performance of GN19-12 (C) series indoor AC high voltage isolation switch meets the standard requirements of &quot;AC high voltage isolation switch and grounding switch&quot;.&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200710/2007101311529434.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 430px&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) Series Indoor AC High Voltage Isolation Switch Model Description&quot; src=&quot;/uploadfiles/200710/2007101311529434.jpg&quot; width=680 height=430&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Environmental conditions for use&lt;BR&gt;1. Altitude not exceeding 1000m;&lt;BR&gt;2. Surrounding air temperature: upper limit+40 ¡æ, lower limit -30 ¡æ;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The seismic intensity shall not exceed 8 degrees;&lt;BR&gt;5. There is no fire, explosion hazard, serious pollution, chemical corrosion, or severe vibration in the area.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated voltage (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4S rated short-time withstand current (effective value) (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated peak withstand current (KA)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S400-12.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/S1250-31.0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S400-12.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S630-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S1000-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/S1250-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 274px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) series indoor AC high voltage isolation switch external dimensions&quot; align=absMiddle src=&quot;/uploadfiles/200610/2006102016260497.jpg&quot; width=274 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) installation dimensions&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162619363.jpg&quot; width=505 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;/P&gt;
&lt;P align=left&gt;Figure 1 GN19-12 series&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 304px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) characteristic curve&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162630475.jpg&quot; width=374 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=304&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 307px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) wiring diagram&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162643666.jpg&quot; width=505 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=307&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=left&gt;Figure 2 GN19-12C series Fig&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 212px&quot; onmouseover=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; border=0 hspace=0 alt=&quot;GN19-12 (C) series indoor AC high voltage isolation switch terminal diagram&quot; align=absMiddle src=&quot;/uploadfiles/200610/20061020162654841.jpg&quot; width=500 onload=&quot;javascript:if(this.width&gt;760)this.width=760;&quot; height=212&gt;&lt;BR&gt;GN19-12(C)/630/400 GN19-12(C)/1000/1250&lt;/P&gt;
&lt;P align=left&gt;Figure 3: Dimensions of Wiring Terminals&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12/1000/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.18&#215;28&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;24&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;GN19-12C/1000/1250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4.14&#215;28&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

