<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Lightning arrester disconnector</title>
       <link>http://www.91way.com</link>
       <description>Lightning arrester disconnector</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:15:54</pubDate>
       <item>
           <title>[Lightning arrester disconnector]TLB-1 Hot melt explosive release device for lightning arrester </title>
           <link>http://www.91way.com/info_en/8214.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:24:23</pubDate>
           <comments></comments>
           <description>The TLB-1 lightning arrester uses a hot melt explosive release device as a special matching product for the lightning arrester, which is used in series with the lightning arrester. When the lightning arrester fails, it can quickly act to remove the faulty lightning arrester from the power grid, and provide a clear disconnection sign for maintenance personnel to discover the fault point and replace the lightning arrester. On the other hand, when the lightning arrester is working normally, the disconnector does not move and exhibits low impedance, which does not affect the protection characteristics of the lightning arrester. The installation of a disconnector lightning arrester is the only way to truly achieve safe and maintenance free use, convenience and reliability. Separators are commonly used in distribution, power station, and line lightning arresters operating in developed countries and regions such as Europe, America, and Japan.&lt;BR&gt;&lt;BR&gt;The disconnector adopts a new thermal explosion design, which has the advantages of fast response and error free operation, and can be used in conjunction with various types of lightning arresters above 3kV. The usage conditions are the same as those of lightning arresters.&lt;BR&gt;The typical ampere second characteristic parameters of TLB-1 thermal explosive disconnector are as follows:&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;Current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point zero five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;DIV align=center&gt;Action time (S)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;0.01กซ0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;0.02กซ0.05&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;0.1กซ0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;0.5กซ1.0&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;20~50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;200~500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112193301295.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 593px; HEIGHT: 477px&quot; border=0 hspace=0 alt=&quot;Installation diagram of TLB-1 lightning arrester with hot melt thermal explosive release device&quot; src=&quot;/upload2015/201501/20150112193301295.jpg&quot; width=593 height=477&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112193312972.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of TLB-1 lightning arrester with hot melt explosive release device&quot; src=&quot;/upload2015/201501/20150112193312972.jpg&quot; width=680 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Lightning arrester disconnector]GLF-RTC type lightning arrester disconnector </title>
           <link>http://www.91way.com/info_en/4263.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:24:14</pubDate>
           <comments></comments>
           <description>The GLF-RTC type lightning arrester disconnector is a device that can disconnect the lightning arrester lead from the system when the lightning arrester is damaged to eliminate continuous system faults and provide visible signs of the accident lightning arrester. GLF-RTC type disconnector, product performance meets the requirements of IEC60099-4.&lt;BR&gt;&lt;BR&gt;Ampere second characteristics of lightning arrester disconnector&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; class=bb border=1 cellSpacing=0 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Action current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Power frequency current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;Square wave impulse current tolerance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;High current tolerance&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Action Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.04&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;..&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;..&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;DIV align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 547px; HEIGHT: 160px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GLF-RTC lightning arrester disconnector&quot; src=&quot;/uploadfiles/200808/200881291825873.jpg&quot; width=547 height=160&gt;&lt;/DIV&gt;
&lt;P align=center&gt;GLF-RTC type lightning arrester disconnector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Lightning arrester disconnector]TL-1 type disconnector </title>
           <link>http://www.91way.com/info_en/4262.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:24:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The TL-1 type lightning arrester disconnector is a device that can disconnect the lightning arrester lead from the system when the lightning arrester is damaged to eliminate continuous system faults and provide visible signs of the accident lightning arrester. TL-1 type disconnector, product performance meets the requirements of IEC60099-4. &amp;nbsp;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/20088129144894.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 547px; HEIGHT: 160px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of TL-1 type disconnector&quot; src=&quot;/uploadfiles/200808/20088129144894.jpg&quot; width=547 height=160&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ampere second characteristics of lightning arrester disconnector&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=15 rowSpan=2 width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Action current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Power frequency current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;Square wave impulse current tolerance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;High current tolerance&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;DIV align=center&gt;Action Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.04&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;&amp;lt;0.02&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;TL-1 type disconnector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Lightning arrester disconnector]TLQ type lightning arrester supporting disconnector </title>
           <link>http://www.91way.com/info_en/3557.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:23:57</pubDate>
           <comments></comments>
           <description>The TLQ type lightning arrester is equipped with a detachment device as a special supporting product of the lightning arrester, which is used in series with the lightning arrester. When the lightning arrester fails, it can quickly operate to remove the faulty lightning arrester from the power grid, and provide a clear detachment sign for maintenance personnel to discover the fault point and replace the lightning arrester. On the other hand, when the lightning arrester is working normally, the disconnector does not move and exhibits low impedance, which does not affect the protection characteristics of the lightning arrester. The installation of a disconnector lightning arrester is the only way to truly achieve safe and maintenance free use, convenience and reliability. Separators are commonly used in distribution, power station, and line lightning arresters operating in developed countries and regions such as Europe, America, and Japan.&lt;BR&gt;&lt;BR&gt;The disconnector adopts a new thermal explosion design, which has the advantages of fast response and error free operation, and can be used in conjunction with various types of lightning arresters above 3kV. The usage conditions are the same as those of lightning arresters.&lt;BR&gt;The typical ampere second characteristic parameters of the disconnector are as follows:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR bgColor=#ffffff&gt;
&lt;TD align=middle&gt;Current (A)&lt;/TD&gt;
&lt;TD align=middle&gt;eight hundred&lt;/TD&gt;
&lt;TD align=middle&gt;two hundred&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;
&lt;TD align=middle&gt;five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point zero five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR bgColor=#ffffff&gt;
&lt;TD align=middle&gt;Action time (S)&lt;/TD&gt;
&lt;TD align=middle&gt;0.01กซ0.02&lt;/TD&gt;
&lt;TD align=middle&gt;0.02กซ0.05&lt;/TD&gt;
&lt;TD align=middle&gt;0.1กซ0.2&lt;/TD&gt;
&lt;TD align=middle&gt;0.5กซ1.0&lt;/TD&gt;
&lt;TD align=middle&gt;20~50&lt;/TD&gt;
&lt;TD align=middle&gt;200~500&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;TLQ type lightning arrester supporting disconnector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Lightning arrester disconnector]Separators for metal oxide surge arresters in non effectively grounded neutral power systems </title>
           <link>http://www.91way.com/info_en/1623.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:23:49</pubDate>
           <comments></comments>
           <description>Separators for metal oxide surge arresters in non effectively grounded neutral power systems&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Lightning arrester disconnector]TLQ-Z Separators for Metal Oxide Surge Arresters in Neutral Point Effective Grounding Power Systems </title>
           <link>http://www.91way.com/info_en/1622.html</link>
           <author></author>
           <guid></guid>
           <category>Lightning arrester disconnector</category>
           <pubDate>2026-6-20 14:23:39</pubDate>
           <comments></comments>
           <description>Detacher for Metal Oxide Surge Arrester in TLQ-Z Neutral Point Effective Grounding Power System&lt;BR&gt;</description>
       </item>
</channel>
</rss>

