           <title>[Temperature relay]ABR19-S7 Three phase thermal protector </title>
           <link>http://www.91way.com/info_en/25156.html</link>
           <author></author>
           <guid></guid>
           <category>Temperature relay</category>
           <pubDate>2026-6-11 17:28:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Working principle of ABR19-S7 three-phase thermal protector:&lt;BR&gt;The operation of the disc shaped thermal bimetallic jump action usually closes the contact system and is sensitive to both temperature and current. When used appropriately, the protector will shut down the motor or equipment when the temperature exceeds the maximum safety standard due to overload or stalling (locking the rotating shaft). The motor needs to cut off the force, and the shorter the time, the better the current operation.&lt;BR&gt;Purpose:&lt;BR&gt;ABR19-S7 three-phase thermal protector motor protector is suitable for overheat and overload protection of motors, electric fans, submersible electric pumps, various types of electric pumps, agricultural equipment, air compressors, and instruments.&lt;BR&gt;&lt;BR&gt;Main technical parameters of ABR19-S7 three-phase thermal protector:&lt;BR&gt;Rated electrical performance: AC380V ------1A~30A&lt;BR&gt;Circuit control type: normally closed/normally open (automatic reset)&lt;BR&gt;Rated operating temperature: 60 &amp;ordm; C to 140 &amp;ordm; C (can be set according to user's actual needs)&lt;BR&gt;Disconnecting temperature tolerance: &#177; 4 &amp;ordm; C, &#177; 5 &amp;ordm; C&lt;BR&gt;Temperature difference between on and off: 15 &amp;ordm; C-60 &amp;ordm; C&lt;BR&gt;Reset temperature tolerance: &#177; 8 &amp;ordm; C, &#177; 10 &amp;ordm; C&lt;BR&gt;Action cycle: ≡ 10000 times&lt;BR&gt;Standard electrical strength: withstand voltage within 2000V per minute without flashover&lt;BR&gt;Standard insulation resistance:&amp;gt;100M 次&lt;BR&gt;Jump off standard temperature: 25 &amp;ordm; C 105% current:&amp;gt;2 hours, no delay 200% current: delay within 2 minutes 600% current: 5-15 seconds delay&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201405/20140505141818152.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 213px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ABR19-S7 three-phase thermal protector&quot; src=&quot;/upload2014/201405/20140505141818152.jpg&quot; width=500 height=213&gt;&lt;/A&gt;&lt;BR&gt;ABR19-S7 three-phase thermal protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Temperature relay]JUC-9F Ultra small temperature relay </title>
           <link>http://www.91way.com/info_en/13826.html</link>
           <author></author>
           <guid></guid>
           <category>Temperature relay</category>
           <pubDate>2026-6-11 17:28:05</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;JUC-9F ultra small temperature relay. This product has a precise structure, reasonable layout, beautiful and generous appearance, compact size, and excellent conductivity. It is a stable and reliable contact conduction temperature sensing relay.&lt;BR&gt;This product is suitable for thermal overload protection of various windings, wire packages, motor stators, transformers, high-power transistors, and various electrical appliances, household appliances, and heating components.&lt;BR&gt;&lt;BR&gt;2﹜ Main technical characteristics of JUC-9F ultra small temperature relay&lt;BR&gt;1. Contact form: one set of dynamic breaking or one set of dynamic closing 1D or 1H&lt;BR&gt;2. Rated load: 220VAC 5A&lt;BR&gt;3. Contact resistance: ≒ 100m 次&lt;BR&gt;4. Insulation resistance: ≡ 100M 次&lt;BR&gt;5. Dielectric withstand voltage: 1500VAC&lt;BR&gt;6. Weight: 3g&lt;BR&gt;&lt;BR&gt;JUC-9F Ultra small Temperature Relay Specification Data Sheet&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;Operating temperature ⊥&lt;/FONT&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Reply temperature ⊥&lt;/P&gt;
&lt;P&gt;(Below the operating temperature)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;error&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Testing method:&lt;/P&gt;
&lt;P&gt;Heating and cooling speed&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;50-120&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;10-30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;&#177;5⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;5-10 ⊥/min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4﹜ Installation size&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100608231843145.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 139px; WIDTH: 376px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JUC-9F ultra small temperature relay&quot; src=&quot;/upload2010/201006/20100608231843145.jpg&quot; width=376 height=139&gt;&lt;/A&gt;&lt;BR&gt;JUC-9F ultra small temperature relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Temperature relay]JUC-31F Ultra small temperature relay </title>
           <link>http://www.91way.com/info_en/13825.html</link>
           <author></author>
           <guid></guid>
           <category>Temperature relay</category>
           <pubDate>2026-6-11 17:27:56</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;JUC-31F ultra small temperature relay.&lt;BR&gt;Structural features: Advanced compression spring structure design, high sensitivity jump process bimetallic sheet forming.&lt;BR&gt;Scope of application: Temperature control and thermal overload protection in electrical equipment, electronic products, household appliances, and circuit boards&lt;BR&gt;&lt;BR&gt;2﹜ Main technical characteristics&lt;BR&gt;1. Contact form: one set of dynamic breaking or one set of dynamic closing 1D or 1H&lt;BR&gt;2. Rated load: 220VAC 1A&lt;BR&gt;3. Contact resistance: ≒ 100m 次&lt;BR&gt;4. Insulation resistance: ≡ 100M 次&lt;BR&gt;5. Dielectric withstand voltage: 1500VAC&lt;BR&gt;6. Weight: 2g&lt;BR&gt;&lt;BR&gt;JUC-31F Ultra small Temperature Relay Specification Data Sheet&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;Operating temperature ⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Reply temperature ⊥&lt;/P&gt;
&lt;P&gt;(Below the operating temperature)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;error&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Testing method:&lt;/P&gt;
&lt;P&gt;Heating and cooling speed&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40-99&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;8-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&#177;5⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;5-10 ⊥/min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;100-130&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;10-35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;DIV align=center&gt;&#177;8⊥&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4﹜ Installation size&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100608231605688.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 390px; WIDTH: 277px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JUC-31F ultra small temperature relay&quot; src=&quot;/upload2010/201006/20100608231605688.jpg&quot; width=277 height=390&gt;&lt;/A&gt;&lt;BR&gt;JUC-31F ultra small temperature relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Temperature relay]KSD-33F Temperature relay </title>
           <link>http://www.91way.com/info_en/13824.html</link>
           <author></author>
           <guid></guid>
           <category>Temperature relay</category>
           <pubDate>2026-6-11 17:27:47</pubDate>
           <comments></comments>
           <description>The KSD-33F temperature relay is a contact sensitive relay designed specifically for temperature control and overheat protection in automotive and motorcycle water tanks, automotive air conditioning compressors, motors, electrical appliances, and other applications.&lt;BR&gt;The relay has a small volume and can be used in high-altitude conditions and high-temperature environments. It can also control large currents and work reliably.&lt;BR&gt;Contact form: a set of dynamic breaking or a set of dynamic closing 1D or 1H&lt;BR&gt;Rated load 24V DC 10A 220V AC 10A&lt;BR&gt;Insulation resistance ≡ 100M 次&lt;BR&gt;Contact resistance ≒ 100m 次&lt;BR&gt;Dielectric withstand voltage ≡ 1000V AC&lt;BR&gt;&lt;BR&gt;KSD-33F Temperature Relay Specification Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Operating temperature range&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;P&gt;Reply temperature&lt;/P&gt;
&lt;P&gt;(Below the operating temperature)&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;error&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV align=center&gt;
&lt;P&gt;test method&lt;/P&gt;
&lt;P&gt;Heating and cooling speed&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;0⊥ㄜ150⊥&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;7⊥ㄜ12⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=center&gt;&#177;3⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5 ⊥/min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;KSD-33F temperature relay external dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100608231324320.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 193px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of KSD-33F temperature relay&quot; src=&quot;/upload2010/201006/20100608231324320.jpg&quot; width=500 height=193&gt;&lt;/A&gt;&lt;BR&gt;KSD-33F temperature relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>