<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - 110KV current transformer</title>
       <link>http://www.91way.com</link>
       <description>110KV current transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:16:11</pubDate>
       <item>
           <title>[110KV current transformer]126KV PASS current transformer </title>
           <link>http://www.91way.com/info_en/2333.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:27:52</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product model: 126KV PASS current transformer&lt;BR&gt;&lt;BR&gt;Product features: This product is used as a current transformer component in 126KV metal enclosed composite electrical appliances. The 126KVPASS current transformer winding follows the following standards:&lt;BR&gt;GB1208-1997 &quot;Current Transformers&quot; (Chinese Standard)&lt;BR&gt;IEC60044-1:2003 &quot;Current transformers&quot; (International Electrotechnical Commission standard)&lt;BR&gt;BS 3938:1973 British Standard Grade X&lt;BR&gt;IEC44-6-1992 Requirement for protective cruuent transformers&lt;BR&gt;For transient performance (International Electrotechnical Commission standard)&lt;BR&gt;GB16847-1997 &quot;Technical Requirements for Transient Characteristics of Protective Current Transformers&quot; (Chinese Standard)&lt;BR&gt;ANSI/IEEE C57.13 &quot;Technical Requirements for Transformers&quot; (American Standard)&lt;BR&gt;&lt;BR&gt;Technical parameters of 126KVPASS current transformer:&lt;BR&gt;&lt;BR&gt;Rated primary current: 100-4000&lt;BR&gt;Rated secondary current: 1, 5&lt;BR&gt;Accuracy level: Can be combined according to customer requirements&lt;BR&gt;0.2s¡¢0.2¡¢0.5s¡¢0.5£»&lt;BR&gt;5P¡¢10P¡¢PX£»&lt;BR&gt;TPY¡¢TPZ¡¢TPX£»&lt;BR&gt;X. (British Standard)&lt;BR&gt;0.3, 0.6, 1.2; (American Standard)&lt;BR&gt;Class C (American Standard)&lt;BR&gt;Rated load (VA): 10-50&lt;BR&gt;Instrument security factor: 5, 10&lt;BR&gt;Accurate limiting factor: 5-40&lt;BR&gt;&lt;BR&gt;Other parameters are determined according to the execution standards. Customers can contact us if they have special requirements or when implementing other standards.&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]126KV GIS current transformer </title>
           <link>http://www.91way.com/info_en/7176.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:26:55</pubDate>
           <comments></comments>
           <description>Product model: 126KV GIS current transformer&lt;BR&gt;&lt;BR&gt;Product features: This product is used as a current transformer component in 126KV metal enclosed composite electrical appliances.&lt;BR&gt;The current transformer winding follows the following standards:&lt;BR&gt;GB1208-1997 &quot;Current Transformers&quot; (Chinese Standard)&lt;BR&gt;IEC60044-1¡Ã2003 ¡¡¡¡¡¡¡¡¡¡¡¶Current transformers¡·¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡£¨ International Electrotechnical Commission Standards)&lt;BR&gt;BS 3938:1973 British Standard Grade X&lt;BR&gt;IEC44-6-1992 ¡¡¡¡¡¡¡¡¡¡¡¡¡¡Requirement for protective cruuent transformers&lt;BR&gt;For transient performance (International Electrotechnical Commission standard)&lt;BR&gt;GB16847-1997 &quot;Technical Requirements for Transient Characteristics of Protective Current Transformers&quot; (Chinese Standard)&lt;BR&gt;ANSI/IEEE C57.13 &quot;Technical Requirements for Transformers&quot; (American Standard)&lt;BR&gt;&lt;BR&gt;Technical parameters of current transformer for 126KVGIS:&lt;BR&gt;Rated primary current: 100-4000&lt;BR&gt;Rated secondary current: 1, 5&lt;BR&gt;Accuracy level: Can be combined according to customer requirements&lt;BR&gt;0.2s¡¢0.2¡¢0.5s¡¢0.5£»&lt;BR&gt;5P¡¢10P¡¢PX£»&lt;BR&gt;TPY¡¢TPZ¡¢TPX£»&lt;BR&gt;X. (British Standard)&lt;BR&gt;0.3, 0.6, 1.2; (American Standard)&lt;BR&gt;Class C (American Standard)&lt;BR&gt;Rated load (VA): 10-50&lt;BR&gt;Instrument security factor: 5, 10&lt;BR&gt;Accurate limiting factor: 5-40&lt;BR&gt;Other parameters are determined according to the execution standards. Customers can contact our company if they have special requirements or when implementing other standards.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LEDH series SF6 insulated electronic current transformers for GIS </title>
           <link>http://www.91way.com/info_en/17304.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:26:16</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The sensing head of the LEDH series SF6 gas insulated electronic current transformer for GIS uses Rogowski coil, without iron core. No magnetic saturation phenomenon, wide frequency band, large dynamic measurement range, and high measurement accuracy.&lt;BR&gt;&lt;BR&gt;1. The maximum voltage of the equipment is 72.5-550kV;&lt;BR&gt;2. Rated primary current 50-8000A;&lt;BR&gt;3. Rated frequency 50/60Hz;&lt;BR&gt;4. Power frequency withstand voltage 160-740kV, full wave impulse withstand voltage 320-1675kV, cut-off impulse withstand voltage 1930kV, and operational impulse withstand voltage 1175kV;&lt;BR&gt;5. Rated gas pressure ¡Ý 0.45;&lt;BR&gt;6. Rated secondary output: IEC 61850-9-1: Measurement channel: 2D41H&lt;BR&gt;Protection channel: 01CFH&lt;BR&gt;IEC 61850-9-2: Rated primary current x 1000&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110831190030707.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 359px&quot; border=0 hspace=0 alt=&quot;LEDH series SF6 gas insulated electronic current transformer model description for GIS&quot; src=&quot;/upload2011/201108/20110831190030707.jpg&quot; width=500 height=359&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;LEDH series SF6 gas insulated electronic current transformer for GIS&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LGBJ-110 (W1,W2,W3)} High Voltage Current Transformer </title>
           <link>http://www.91way.com/info_en/27636.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:26:12</pubDate>
           <comments></comments>
           <description>&lt;P&gt;LGBJ-110 (W1, W2, W3) High Voltage Current Transformer Execution Standard&lt;BR&gt;The product performance complies with the national standard G81208 &quot;Current Transformers&quot;&lt;BR&gt;&lt;BR&gt;Structure and Performance Characteristics of LGBJ-110 (W1, W2, W3) High Voltage Current Transformer&lt;BR&gt;Organic composite insulation, oil-free, porcelain free, and gas free (SF6), with maintenance free operation. The external insulation is made of silicone rubber umbrella skirt, which has strong resistance to pollution, high voltage of pollution and wet flashover, low dielectric loss factor and local discharge level, small crystal volume, light weight, and easy transportation and installation.&lt;BR&gt;&lt;BR&gt;Ordering Instructions&lt;BR&gt;When placing an order, please specify the product model, rated current ratio, number and level combination of secondary windings, whether the secondary winding has a tap, and the rated negative value of the secondary winding&lt;BR&gt;Dutch, anti pollution level.&lt;BR&gt;If the product is used in high-altitude areas, please indicate the altitude.&lt;BR&gt;Please consult with our technical department for products with special requirements.&lt;BR&gt;&lt;BR&gt;1. Hanging board; 2 boxes; 3. Famous brand and secondary terminals; 4. Silicone rubber umbrella group; 5. Primary well connection: 6. Primary wiring terminal&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201905/20190512190036882.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 324px; HEIGHT: 366px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LGBJ-110 (W1, W2, W3) high-voltage current transformer&quot; src=&quot;/upload2019/201905/20190512190036882.jpg&quot; width=324 height=366&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201905/20190512190045956.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 577px&quot; border=0 hspace=0 alt=&quot;Technical parameters of LGBJ-110 (W1, W2, W3) high-voltage current transformer&quot; src=&quot;/upload2019/201905/20190512190045956.jpg&quot; width=680 height=577&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LZW-110 series high-voltage current transformer </title>
           <link>http://www.91way.com/info_en/24176.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:26:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of LZW-110 series high-voltage current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204182745511.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 537px; HEIGHT: 286px&quot; border=0 hspace=0 alt=&quot;Technical parameters of LZW-110 series high-voltage current transformer&quot; src=&quot;/upload2013/201312/20131204182745511.jpg&quot; width=537 height=286&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Dimensions of LZW-110 series high-voltage current transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204182757521.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LZW-110 series high-voltage current transformer&quot; src=&quot;/upload2013/201312/20131204182757521.jpg&quot; width=535 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LZW-110 series high-voltage current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]SVAS126 series high-voltage current transformer </title>
           <link>http://www.91way.com/info_en/24167.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of SVAS126 series high-voltage current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131203194128705.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 534px; HEIGHT: 443px&quot; border=0 hspace=0 alt=&quot;Technical parameters of SVAS126 series high-voltage current transformer&quot; src=&quot;/upload2013/201312/20131203194128705.jpg&quot; width=534 height=443&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Outline drawing of SVAS126 series high-voltage current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131203194141551.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 420px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of SVAS126 series high-voltage current transformers&quot; src=&quot;/upload2013/201312/20131203194141551.jpg&quot; width=535 height=420&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SVAS126 series high-voltage current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LGB-110kV High Voltage Current Transformer </title>
           <link>http://www.91way.com/info_en/19902.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:46</pubDate>
           <comments></comments>
           <description>LGB-110kV High Voltage Current Transformer&lt;BR&gt;&lt;BR&gt;Rated voltage of the system: 110kV&lt;BR&gt;System maximum voltage: 126 kV&lt;BR&gt;System rated frequency: 50Hz&lt;BR&gt;System neutral grounding method: direct&lt;BR&gt;Rated primary current 5A~2500A&lt;BR&gt;Rated secondary current 1A or 5A&lt;BR&gt;Insulation level 126/185/450&lt;BR&gt;Creepage distance ¡Ý 31mm/kV (Grade IV pollution)&lt;BR&gt;Rated short-time thermal stability current 31.5kA/1second&lt;BR&gt;Rated short-time dynamic stability current (peak) 80 Ka&lt;BR&gt;Partial discharge level: ¡Ü 5pC at 1.2Um/¡Ì 3 voltage&lt;BR&gt;&lt;BR&gt;LGB-110kV High Voltage Current Transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LB6-110KV(W2)(GYW2) Oil immersed current transformer </title>
           <link>http://www.91way.com/info_en/15758.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:33</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;LB6-110KV (W2) (GYW2) oil immersed current transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201102/20110209100259468.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of LB6-110 (W2) (GYW2) oil immersed current transformer&quot; src=&quot;/upload2010/201102/20110209100259468.jpg&quot; width=680 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201102/20110209100345118.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 230px&quot; border=0 hspace=0 alt=&quot;Technical parameters of LB6-110 (W2) (GYW2) oil immersed current transformer&quot; src=&quot;/upload2010/201102/20110209100345118.jpg&quot; width=680 height=230&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LB6-110 (W2) (GYW2) oil immersed current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LVB-110 High Voltage Current Transformer </title>
           <link>http://www.91way.com/info_en/16708.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:29</pubDate>
           <comments></comments>
           <description>The LVB-110 current transformer is an inverted transformer. Five secondary windings are combined into a suspended ring and fixed in the oil tank on the upper part of the porcelain bushing; The secondary lead passes through the porcelain sleeve and is led out from the secondary wiring board on the base; The main insulation adopts a capacitive oil paper insulation structure. A winding is composed of a copper rod and a concentric circular tube, which are connected in series or parallel outside the oil tank. The upper part of the oil tank is equipped with a metal expander, and the side is equipped with a pressure release device for 0.35 &#177; 0.02Mpa blasting. There is an oil drain valve installed on the base for taking oil samples.&lt;BR&gt;&lt;BR&gt;Main technical parameters of LVB-110 high-voltage current transformer:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center 0=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Rated voltage (KV)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Polarity, rated frequency (Hz)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;Reduce, 50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Rated primary current (A)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;2 &#215; 600/5 (secondary winding tap is 2 &#215; 300/5)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Rated secondary current (A)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Accuracy level and combination&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;0.2/0.5/5P2/5P1/5P2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Rated load (VA)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;50 (tap is 30)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Rated insulation level (KV)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;126/185/450&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Partial discharge level (PC)&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;¡Ü5PC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Instrument security factor&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;FS¡Ü5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;36%&quot;&gt;Accurate limit coefficient&lt;/TD&gt;
&lt;TD width=&quot;64%&quot;&gt;5P1£ºALF¡Ý20£» 5P2£ºALF¡Ý15&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204180928868.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 248px&quot; border=0 hspace=0 alt=&quot;Technical parameters of LVB-110 high-voltage current transformer&quot; src=&quot;/upload2013/201312/20131204180928868.jpg&quot; width=533 height=248&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204180934875.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 452px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LVB-110 high-voltage current transformer&quot; src=&quot;/upload2013/201312/20131204180934875.jpg&quot; width=535 height=452&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LVB-110 High Voltage Current Transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LCWD2P-110 High Voltage Current Transformer </title>
           <link>http://www.91way.com/info_en/16707.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:20</pubDate>
           <comments></comments>
           <description>The LCWD2P-110 current transformer is a porcelain box type oil paper insulated &quot;8&quot; - shaped structure. Wrap the secondary coil on the circular iron core, combine the three secondary windings together, and wrap them with insulation. Then wind a primary coil through its window, and wrap insulation around the primary coil. The primary and secondary coils form an &quot;8&quot; shape. Two sets of identical coils can be wound in one go, and two current ratios can be obtained by series or parallel connection of the output terminals on the oil storage tank (small current in series connection and twice the primary current in parallel connection). 1¡¢ The secondary coil (body) is inside the porcelain sleeve and filled with transformer oil. The device body is fixed on the base, and the secondary output is sealed and led out by a small porcelain sleeve, and fixed on the base for wiring. The output end of the primary coil is also sealed and fixed on the outer wall of the oil storage tank with a small porcelain sleeve, making it easy to connect in series or parallel. The oil storage tank is equipped with a corrugated metal expander, which is also sealed. When the transformer oil of the transformer expands or contracts due to temperature changes, the volume of the metal expander also expands or contracts, maintaining a slight positive pressure inside the transformer. Therefore, it can prevent the external atmosphere from entering the transformer and causing the insulation of the transformer to become damp. The transformer is a fully sealed structure that can prevent moisture from entering and isolate the transformer oil from contact with the outside world, delay the aging of the transformer oil, and thus extend the life or maintenance period of the transformer.&lt;BR&gt;&lt;BR&gt;Main technical data of LCWD2P-110 high-voltage current transformer:&lt;BR&gt;1. Rated primary current: one of 2 &#215; 50, 2 &#215; 75, 2 &#215; 100, 2 &#215; 150, 2 &#215; 200, 2 &#215; 300, 2 &#215; 400, and 2 &#215; 600A.&lt;BR&gt;2. Rated secondary current: 5A.&lt;BR&gt;3. Accuracy level combination: 0.5/D/D level.&lt;BR&gt;4. Rated output for Class 0.5 and Class D: 50VA (cos §å=0.8 hysteresis).&lt;BR&gt;5. D-level 10% multiples are 15 times.&lt;BR&gt;6. One second thermal stability current Ith=0.065I1nKA (I1n is the rated primary current), with a maximum of 45KA.&lt;BR&gt;7. The dynamic stable current Idyn is 0.135I1nKA, with a maximum of 100KA.&lt;BR&gt;8. Insulation level.&lt;BR&gt;8.1 The primary winding to secondary winding and ground frequency test voltage is 250KV, lasting for 1 minute.&lt;BR&gt;The power frequency test voltage between the secondary windings and the ground is 2KV, and the duration is 1 minute.&lt;BR&gt;8.3 The full wave impulse test voltage for 1.5/40 microseconds is 425KV.&lt;BR&gt;&lt;BR&gt;LCWD2P-110 High Voltage Current Transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LVQB-110(W2) Silicone rubber composite sleeve sulfur hexafluoride current transformer </title>
           <link>http://www.91way.com/info_en/15752.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:25:02</pubDate>
           <comments></comments>
           <description>&lt;P&gt;LVQB-110 (W2) silicone rubber composite sleeve sulfur hexafluoride current transformer rated insulation level: rated short-time power frequency withstand voltage 230kV/rated lightning impulse withstand voltage 5500kV (peak).&lt;BR&gt;The change in the rated current ratio of the product can be obtained by swapping the series parallel connection of the primary winding, such as 2 &#215; 300/5; It can also be obtained by changing the middle tap of the secondary winding, as shown in Figure 300-600/5.&lt;BR&gt;&lt;BR&gt;LVQB-110 (W2) silicone rubber composite sleeve sulfur hexafluoride current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131203194558163.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 425px&quot; border=0 hspace=0 alt=&quot;Technical parameters of LVQB-110 (W2) silicone rubber composite sleeve sulfur hexafluoride current transformer&quot; src=&quot;/upload2013/201312/20131203194558163.jpg&quot; width=533 height=425&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131203194604926.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 523px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LVQB-110 (W2) silicone rubber composite sleeve sulfur hexafluoride current transformer&quot; src=&quot;/upload2013/201312/20131203194604926.jpg&quot; width=535 height=523&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LVQB-110 (W2) silicone rubber composite sleeve sulfur hexafluoride current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LB3-110 type current transformer </title>
           <link>http://www.91way.com/info_en/4239.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:45</pubDate>
           <comments></comments>
           <description>The LB3-110 current transformer is an electromagnetic oil paper insulated, outdoor, fully enclosed product. Used for current and energy measurement, as well as relay protection device power supply in AC power systems with a maximum voltage of 126kV and a rated frequency of 50Hz or 60Hz. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The LB3-110 current transformer can be equipped with 4 secondary windings, and the secondary measurement winding made of high permeability microcrystalline alloy can ensure measurement accuracy of 0.2 or 0.2S level.&lt;BR&gt;This product comes with a stainless steel fully enclosed metal expander device; Imported rubber pads are used for sealing. All product casings are made of new processes and materials such as hot-dip galvanizing and stainless steel standard parts, ensuring that the entire machine is rust free. Due to its reasonable structure, advanced technology, novel materials, it ensures the reliable, safe, and durable operation of the product.&lt;BR&gt;Usage environment&lt;BR&gt;Maximum ambient temperature:+40 ¡æ Minimum temperature: -30 ¡æ Daily average temperature not exceeding+30 ¡æ (special requirements products can be provided)&lt;BR&gt;&lt;BR&gt;Main technical parameters of LB3-110 current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=3 width=650 align=center heihgt=&quot;200px&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;serial number&lt;/TD&gt;
&lt;TD&gt;name&lt;/TD&gt;
&lt;TD&gt;unit&lt;/TD&gt;
&lt;TD&gt;data&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;
&lt;TD&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;Rated primary current&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;
&lt;TD&gt;2&#215;50~2&#215;800&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;Rated secondary current&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;
&lt;TD&gt;5 or 1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;Accurate level combination&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;P/P/P/0.2(0.2S)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;Instrument security factor&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&amp;lt;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;Accurate limit coefficient&lt;/TD&gt;
&lt;TD&gt;VA&lt;/TD&gt;
&lt;TD&gt;15. 20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seven&lt;/TD&gt;
&lt;TD&gt;total weight&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;
&lt;TD&gt;540~600&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Ordering Instructions&lt;BR&gt;Please indicate the product name, product model, current ratio, level combination, quantity, etc. when placing an order.&lt;BR&gt;If the altitude of the usage location exceeds 1000m, and it is used in polluted areas or has other special requirements, it shall be specified in the contract.&lt;BR&gt;&lt;BR&gt;Overall Dimension Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/200886165552648.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 642px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LB3-110 current transformer&quot; src=&quot;/uploadfiles/200808/200886165552648.jpg&quot; width=500 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;LB3-110 type current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LVQB6-110W2 series high-voltage transformer </title>
           <link>http://www.91way.com/info_en/3626.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008519145616957.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;LVQB6-110W2 series high-voltage transformer model description&quot; src=&quot;/uploadfiles/200805/2008519145616957.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008519145836753.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 575px; HEIGHT: 678px&quot; border=0 hspace=0 alt=&quot;Technical Parameters Table of LVQB6-110W2 Series High Voltage Transformer&quot; src=&quot;/uploadfiles/200805/2008519145836753.jpg&quot; width=575 height=678&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008519145846297.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 828px&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of LVQB6-110W2 series high-voltage transformer&quot; src=&quot;/uploadfiles/200805/2008519145846297.jpg&quot; width=533 height=828&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;LVQB6-110W2 series high-voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LB6-126KV series high-voltage current transformer </title>
           <link>http://www.91way.com/info_en/3624.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:28</pubDate>
           <comments></comments>
           <description>The LB6-126KV series high-voltage current transformer is an oil immersed fully sealed insulation structure and outdoor product, suitable for use in power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 110kV for energy metering, current measurement, and relay protection.&lt;BR&gt;&lt;BR&gt;2¡¢ LB6-126KV series high-voltage current transformer model meaning&lt;BR&gt;&lt;BR&gt;
&lt;DIV&gt;&lt;A href=&quot;/uploadfiles/200805/2008519144844436.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 323px; HEIGHT: 149px&quot; border=0 hspace=0 alt=&quot;Model Description of LB6-110 Series High Voltage Transformer&quot; src=&quot;/uploadfiles/200805/2008519144844436.jpg&quot; width=323 height=149&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;BR&gt;Anti pollution level (W2 is level III pollution, W3 is level IV pollution, GY is high-altitude area)&lt;BR&gt;Rated voltage level, kV&lt;BR&gt;Design Number&lt;BR&gt;With protection level&lt;BR&gt;current transformer&lt;BR&gt;&lt;BR&gt;3¡¢ Product Features and Structure Introduction&lt;BR&gt;The LB6-126KV series high-voltage current transformer is an oil immersed fully sealed insulation structure, with the main insulation being an oil immersed paper capacitor composite insulation and the primary winding being in a &quot;U&quot; shape; The device is installed in an oil tank filled with transformer oil and undergoes vacuum drying and oil immersion treatment; The primary output terminal is connected in series or parallel to the oil storage tank as an external switching device, which can be switched outside the oil storage tank; A stainless steel metal expander is used as the oil compensation device, and the oil level indicator is indicated by the pointer position on the upper window of the expander. The secondary winding can be combined arbitrarily according to user needs, with strong load capacity. The internal electric field distribution is uniform and the field strength is low, with low partial discharge.&lt;BR&gt;&lt;BR&gt;4¡¢ Technical parameters of LB6-126KV series high-voltage current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated insulation level kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;126/230/550&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated primary current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;2&#215;50¡«2&#215;1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated secondary current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;5 or 1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;0.2S, 0.5S, 0.2, 0.5, 5P, 10P can be equipped with taps according to requirements&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated output VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;20. 30, 40, 50, 60, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Number of secondary coils&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;3~8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Accurate level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;Any combination of 0.2S/0.5/5P/5P/5P, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Measurement level instrument security factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;Fs¡Ü5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Protection level accuracy limit coefficient&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;10. 15, 20, 25, 30, 35, 40, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Short time thermal current kA/s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;22.5~50/1, can be specially designed according to user needs&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated dynamic stability current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;56.25~125, can be specially designed according to user needs&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Product dielectric loss factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü0.005&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Partial discharge amount pC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Radio interference level ¦Ì V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;External insulation creepage distance mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;31503906, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Product altitude m&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü3500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5¡¢ LB6-126KV series high-voltage current transformer appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200851914499925.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 430px&quot; border=0 hspace=0 alt=&quot;LB6-126KV series high-voltage current transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200851914499925.jpg&quot; width=650 height=430&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LB6-126KV series high-voltage current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LB7-110W2(LB7-126W2) series high-voltage transformer </title>
           <link>http://www.91way.com/info_en/3622.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:20</pubDate>
           <comments></comments>
           <description>The LB7-110 series high-voltage transformer is an oil immersed fully sealed insulation structure and outdoor product, suitable for use in power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 110kV for energy metering, current measurement, and relay protection.&lt;BR&gt;&lt;BR&gt;
&lt;DIV&gt;&lt;A href=&quot;/uploadfiles/200805/2008519144130844.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 333px; HEIGHT: 167px&quot; border=0 hspace=0 alt=&quot;Model Description of LB7-110W2 (LB7-126W2) Series High Voltage Transformer&quot; src=&quot;/uploadfiles/200805/2008519144130844.jpg&quot; width=333 height=167&gt;&lt;/A&gt;&lt;/DIV&gt;
&lt;DIV&gt;3¡¢ Introduction to the Characteristics and Structure of LB7-110W2 (LB7-126W2) Series High Voltage Transformers&lt;/DIV&gt;
&lt;DIV&gt;This type of current transformer is an oil immersed fully sealed insulation structure, with the main insulation being a capacitive oil paper composite insulation. The primary winding is a deformed &quot;U&quot; byte shaped 1/4 aluminum tube or semi-circular aluminum tube or semi-circular copper tube, which improves the dynamic and thermal stability of the product; The device is installed in an oil tank filled with transformer oil and undergoes vacuum drying and oil immersion treatment; The primary output terminal is drilled on the upper part of the porcelain sleeve and can be connected in series or parallel outside the porcelain sleeve, or outside the oil storage tank; A stainless steel metal expander is used as the oil compensation device, and the oil level indicator is indicated by the pointer position on the upper window of the expander. The secondary winding can be combined arbitrarily according to user needs, with strong load capacity. The internal electric field distribution is uniform and the field strength is low, with low partial discharge.&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV&gt;4¡¢ Technical parameters of LB7-110W2 (LB7-126W2) series high-voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated insulation level kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;126/230/550&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated primary current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;2&#215;50¡«2&#215;1250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated secondary current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;5 or 1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;0.2S, 0.5S, 0.2, 0.5, 5P, 10P can be equipped with taps according to requirements&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated output VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;20. 30, 40, 50, 60, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Number of secondary coils&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;3~8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Accurate level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;Any combination of 0.2S/0.5/5P/5P/5P, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Measurement level instrument security factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;Fs¡Ü5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Protection level accuracy limit coefficient&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;10. 15, 20, 25, 30, 35, 40, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Short time thermal current kA/s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;22.5~50/1, can be specially designed according to user needs&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Rated dynamic stability current kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;56.25~125, can be specially designed according to user needs&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Product dielectric loss factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü0.005&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Partial discharge amount pC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Radio interference level ¦Ì V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;External insulation creepage distance mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;31503906, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=258&gt;
&lt;DIV&gt;Product altitude m&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=350&gt;
&lt;DIV&gt;¡Ü3500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;5¡¢ LB7-110W2 (LB7-126W2) series high-voltage transformer appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008519144154986.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 523px; HEIGHT: 421px&quot; border=0 hspace=0 alt=&quot;LB7-110W2 (LB7-126W2) series high-voltage transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008519144154986.jpg&quot; width=523 height=421&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851914429629.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 322px; HEIGHT: 113px&quot; border=0 hspace=0 alt=&quot;Installation data of LB7-110W2 (LB7-126W2) series high-voltage transformer&quot; src=&quot;/uploadfiles/200805/200851914429629.jpg&quot; width=322 height=113&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LB7-110 series high-voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LRGB-110W2 series current transformers </title>
           <link>http://www.91way.com/info_en/3160.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:12</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852183542722.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 2600px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of LRGB-110W2 series current transformers&quot; src=&quot;/uploadfiles/200805/200852183542722.gif&quot; width=560 height=2600&gt;&lt;/A&gt;&lt;BR&gt;LRGB-110W2 series current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV current transformer]LCWB6-110(W2),LCWB6-110GYW2 series current transformers </title>
           <link>http://www.91way.com/info_en/3159.html</link>
           <author></author>
           <guid></guid>
           <category>110KV current transformer</category>
           <pubDate>2026-6-20 11:24:03</pubDate>
           <comments></comments>
           <description>The LCWB6-110 (W2) and LCWB6-110GYW2 series current transformers are oil tank ceramic bushing capacitive insulated U-shaped structures. The primary coil adopts a traditional U-shaped structure, which has good free characteristics and thermal breakdown stability.&lt;BR&gt;The capacitive structure has a relatively uniform voltage distribution due to the level adjustment effect.&lt;BR&gt;&lt;BR&gt;Main technical data of LCWB6-110 (W2), LCWB6-110GYW2 series current transformers:&lt;BR&gt;&lt;BR&gt;1. Rated primary current: 2 &#215; 50, 2 &#215; 75, 2 &#215; 100, 2 &#215; 150, 2 &#215; 200, 2 &#215; 300, 2 &#215; 400, 2 &#215; 500, 2 &#215; 600 (2 &#215; 300), 2 &#215; 750 (2 &#215; 400), or 2 &#215; 1000 (2 &#215; 500) A.&lt;BR&gt;2. Rated secondary current: 5A or 1A.&lt;BR&gt;3. Rated frequency: 50Hz.&lt;BR&gt;4. Accuracy level combination: p/p/p0.5 level.&lt;BR&gt;5. Rated output.&lt;BR&gt;5.1 For rated currents of 2 &#215; 50-2 &#215; 1000/5A, the rated output for levels 0.5 and P is 50VA.&lt;BR&gt;5.2 For rated currents of 2 &#215; 50-2 &#215; 1000/1A, the rated output for levels 0.5 and P is 30VA.&lt;BR&gt;5.3 For rated currents of 2 &#215; 600, 2 &#215; 750, and 2 &#215; 1000/5A, the rated output of the 0.5 level winding tap (corresponding current ratios of 2 &#215; 300, 2 &#215; 400, and 2 &#215; 500/1A) is 20VA.&lt;BR&gt;6. 0.5 level instrument security factor (Fs): Fs ¡Ü 20.&lt;BR&gt;7. P-level 10% multiples are 15 times.&lt;BR&gt;8. The rated 1-second thermal stability current level dynamic stability current shall not be less than the values specified in the table below.&lt;BR&gt;&lt;BR&gt;LCWB6-110 (W2), LCWB6-110GYW2 series current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated primary current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;75-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100-200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;150-300&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300-600&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time thermal current (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5.3-10.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.9-15.8&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10.5-21&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15.8-31.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;21-42&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;31.5-45&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dynamic stability current (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;13-26&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;27-54&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40-80&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;54-108&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80-115&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852183331114.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 575px; HEIGHT: 2633px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of LCWB6-110 (W2), LCWB6-110GYW2 series current transformers&quot; src=&quot;/uploadfiles/200805/200852183331114.gif&quot; width=575 height=2633&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>