           <title>[electromagnetic lock]JSY-1 type electromagnetic control program lock </title>
           <link>http://www.91way.com/info_en/17008.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 21:19:24</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JSY-1 Electromagnetic Control Program Lock&lt;BR&gt;1. Overview&lt;BR&gt;1.1 Product Model and Name: JSY-1 Mechanical Program Key Electromagnetic Control Lock (hereinafter referred to as Electric Control Lock)&lt;BR&gt;1.2 Main purpose and scope of application of the product&lt;BR&gt;The electric control lock is suitable for matching with the JSN (W) 1A series mechanical program lock on the comprehensive automation control screen. Its main function is to prevent misoperation between the circuit breaker and the isolating switch. The JSN (W) 1A series mechanical program lock is strengthened for management and is suitable for any form of control switch and JSN (W) 1A series mechanical program to perform five prevention operation.&lt;BR&gt;2. Environmental conditions for use&lt;BR&gt;a. Surrounding air temperature: upper limit+60 ¡æ, lower limit -30 ¡æ;&lt;BR&gt;b. Humidity: The daily average relative humidity should not exceed 95%, and the monthly average should not exceed 90%. During high humidity periods, condensation may occur when the temperature drops sharply;&lt;BR&gt;c. The place of use should be free from fire, explosion hazards, chemical corrosion, and frequent severe vibrations;&lt;BR&gt;d. Altitude: 3000m.&lt;BR&gt;3. Main specifications and technical parameters&lt;BR&gt;Rated operating frequency 50Hz&lt;BR&gt;Rated working voltage: AC110, 220V; DC110£¬220V£»&lt;BR&gt;Rated control switch current: 6A at 220V and 10A at 110V.&lt;BR&gt;4. Instructions for Using JSY-1 Electromagnetic Control Program Lock&lt;BR&gt;Closing position: When the circuit breaker is in the closing position, the electric lock has no operating power supply, the control circuit is closed, and the circuit breaker can perform opening and closing operations.&lt;BR&gt;Opening position: When the circuit breaker is in the opening position, the indicator light of the electric control lock lights up, indicating that there is operating power. Press the electric control lock button and rotate the mechanical program lock key counterclockwise to remove the key and perform the knife switch operation. After removing the key, the control circuit of this electric control lock is disconnected and the circuit breaker closing operation cannot be performed.&lt;BR&gt;Circuit breaker maintenance: Open the circuit breaker, remove the key from the electric control lock, open the isolation switch, press the electric control lock button, insert the mechanical program lock key into the lock hole of the electric control lock, rotate it clockwise by 50 &#176; to the red line position, release the button, lock the key, and close the control circuit of the electric control lock. At this time, the circuit breaker opening and closing test or maintenance can be carried out.&lt;BR&gt;Special reminder: After the circuit breaker is in the open position and the mechanical program lock key completes all operations, insert the electronic control lock, turn on the power, and lock the key clockwise 50 &#176; to the red line position. After completing the operation, turn the key to ensure it is locked before closing.&lt;BR&gt;5. Installation and debugging&lt;BR&gt;Before installation, the specifications of the purchased electric control lock should be checked to ensure that the technical parameters are consistent. After confirmation, a power test should be conducted. The program lock key should be inserted, removed, and rotated freely, with reliable locking and no jamming phenomenon.&lt;BR&gt;5.2 Wiring methods refer to the wiring schematic diagram&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201108/20110828161542856.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 254px; WIDTH: 618px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JSY-1 Electromagnetic Control Program Lock Principle Wiring Diagram&quot; src=&quot;/upload2011/201108/20110828161542856.jpg&quot; width=618 height=254&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;5.3 Electric control locks must be equipped during installation, and outdoor electric control locks come with accessories that can be installed in outdoor mechanism control boxes.&lt;BR&gt;6. Maintenance and repair&lt;BR&gt;When powered on normally, the indicator light should be on. Press the electric control lock button, and the indicator light should go out. The coil should be reliably engaged. If the indicator light does not light up when powered on and the iron core in the coil cannot be heard when pressing the electric control lock button, it indicates that the electric control lock coil is not connected. Further inspection, repair or replacement should be carried out. If the lock bolt cannot lock the program lock key after being powered on and engaged, it indicates that the lock bolt is blocked and stuck after being engaged. At this time, the panel needs to be disassembled to adjust the screws that fix the coil bracket appropriately to restore its work.&lt;BR&gt;7. Ordering Notice&lt;BR&gt;When placing an order, it is necessary to specify the closing current and control voltage of the switch closing contactor, and provide the matching scheme and scheme number for the JSN (W) 1 series mechanical program lock.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]Stainless steel outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/16529.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 21:15:21</pubDate>
           <comments></comments>
           <description>DSW1-III-Y stainless steel outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]JSN(W)1A Mechanical Five Protection Program Lock </title>
           <link>http://www.91way.com/info_en/16390.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 21:13:35</pubDate>
           <comments></comments>
           <description>I. Overview&lt;BR&gt;JSN (W) 1 series five proof program lock is a mechanical lock used for high-voltage switchgear. This lock forces operators to operate electrical equipment according to the prescribed safety operating procedures, thereby avoiding accidents caused by misoperation of electrical equipment and achieving the requirements proposed by the power supply department&lt;BR&gt;&lt;BR&gt;a. Prevent accidental opening and closing of switches;&lt;BR&gt;b. Prevent the opening and closing of isolation switches with load;&lt;BR&gt;c: Prevent accidental entry into electrified compartments;&lt;BR&gt;d: Prevent the hanging of live grounding wires (closing the grounding knife switch);&lt;BR&gt;e: Prevent the grounding wire (grounding knife switch) from closing;&lt;BR&gt;According to the &quot;five prevention&quot; requirements, this product is an ideal anti misoperation device for high-voltage electrical equipment.&lt;BR&gt;This product only requires one key to operate multiple locks according to the specified circuit, and has the ability to distinguish the opening and closing status of each knife switch, cabinet door, and mechanism. Complies with JB/T8455-1996 &quot;General Technical Conditions for Mechanical Locks for High Voltage Switchgear&quot; of the Ministry of Machinery. Passed the batch trial production review and appraisal organized by the original Ministry of Machinery and Ministry of Water and Electricity.&lt;BR&gt;&lt;BR&gt;2¡¢ Scope of use&lt;BR&gt;JSN (W) 1A mechanical five proof program lock is suitable for wiring methods of various voltage levels and various indoor and outdoor power distribution devices.&lt;BR&gt;&lt;BR&gt;3¡¢ Ordering Notice&lt;BR&gt;1. The customer provides a main wiring diagram and an electrical equipment installation diagram. Design programs according to user requirements.&lt;BR&gt;2. The customer has a special operating mode, and our company has developed procedures according to the customer's requirements.&lt;BR&gt;3. The guide sleeve of the indoor knife switch lock is M14 &#215; 1.5, and the diameter of the lock bolt is 9mm. If there are other sizes of threaded holes, please explain.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSW-Z outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/4958.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 19:38:43</pubDate>
           <comments></comments>
           <description>Usage conditions of DSW-Z outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;1. The ambient temperature ranges from+40 ¡æ to -30 ¡æ, and in high-altitude regions, it ranges from+40 ¡æ to -40 ¡æ.&lt;BR&gt;2. The altitude shall not exceed 2500m.&lt;BR&gt;3. The pollution level of the operating environment is Class 0, Class I or Class II in GB5582-85 &quot;Pollution Level of External Insulation of High Voltage Power Equipment&quot;.&lt;BR&gt;3. The installation site should be free from fire, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;&lt;BR&gt;DSW-Z outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSW4-Y outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/4957.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 19:38:35</pubDate>
           <comments></comments>
           <description>DSW4G-Z and DSW4G-Y outdoor electromagnetic locks are electrical mechanical interlocking devices for preventing misoperation of high-voltage isolation switch equipment with voltage levels of 10KV and above. They are mainly used to prevent misoperation between the isolation switch, grounding switch, and circuit breaker of the human operated mechanism.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSW4G-Z outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/4956.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 19:38:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;DSW4G-Z and DSW4G-Y outdoor electromagnetic locks are electrical mechanical interlocking devices for preventing misoperation of high-voltage isolation switch equipment with voltage levels of 10KV and above. They are mainly used to prevent misoperation between the isolation switch, grounding switch, and circuit breaker of the human operated mechanism.&lt;BR&gt;&lt;BR&gt;Product model and meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942133654873.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 218px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of DSW4G-Z Outdoor Electromagnetic Lock&quot; src=&quot;/uploadfiles/200904/200942133654873.gif&quot; width=218 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Technical parameters of DSW4G-Z outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. The ambient temperature ranges from+40 ¡æ to -30 ¡æ, and in high-altitude regions, it ranges from+40 ¡æ to -40 ¡æ.&lt;BR&gt;2. The altitude shall not exceed 2500m.&lt;BR&gt;3. The pollution level of the operating environment is Class 0, Class I or Class II in GB5582-85 &quot;Pollution Level of External Insulation of High Voltage Power Equipment&quot;.&lt;BR&gt;3. The installation site should be free from fire, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;Ordering Instructions&lt;BR&gt;1. Please indicate the product model and quantity when placing an order.&lt;BR&gt;2. If it is necessary to configure and assemble the connecting accessories with the operating mechanism, the model and quantity of the operating mechanism should be indicated.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSW1G-Z outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/4955.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 19:38:16</pubDate>
           <comments></comments>
           <description>The DSW1G-Z and DSW1G-Y outdoor electromagnetic locks are electrical mechanical interlocking devices for preventing misoperation of high-voltage isolation switch equipment with voltage levels of 10KV and above. They are mainly used to prevent misoperation between the isolation switch, grounding switch, and circuit breaker of the human operated mechanism.&lt;BR&gt;Product model and meaning&lt;BR&gt;&lt;BR&gt;Technical parameters of DSW1G-Z outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. The ambient temperature ranges from+40 ¡æ to -30 ¡æ, and in high-altitude regions, it ranges from+40 ¡æ to -40 ¡æ.&lt;BR&gt;2. The altitude shall not exceed 2500m.&lt;BR&gt;3. The pollution level of the operating environment is Class 0, Class I or Class II in GB5582-85 &quot;Pollution Level of External Insulation of High Voltage Power Equipment&quot;.&lt;BR&gt;3. The installation site should be free from fire, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;Ordering Instructions&lt;BR&gt;1. Please indicate the product model and quantity when placing an order.&lt;BR&gt;2. If it is necessary to configure and assemble the connecting accessories with the operating mechanism, the model and quantity of the operating mechanism should be indicated.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSWG4-Y outdoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/4954.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 19:38:08</pubDate>
           <comments></comments>
           <description>&lt;P&gt;DSWG4-Z and DSWG4-Y outdoor electromagnetic locks are electrical mechanical interlocking devices for preventing misoperation of high-voltage isolation switch equipment with voltage levels of 10KV and above. They are mainly used to prevent misoperation between the isolation switch, grounding switch, and circuit breaker of the human operated mechanism.&lt;BR&gt;&lt;BR&gt;Product model and meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942132128271.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 218px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DSWG4-Y Outdoor Electromagnetic Lock Model Description&quot; src=&quot;/uploadfiles/200904/200942132128271.gif&quot; width=218 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Technical parameters of DSWG4-Y outdoor electromagnetic lock&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942132155274.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 157px; WIDTH: 314px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of DSWG4-Y outdoor electromagnetic lock&quot; src=&quot;/uploadfiles/200904/200942132155274.gif&quot; width=314 height=157&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. The ambient temperature ranges from+40 ¡æ to -30 ¡æ, and in high-altitude regions, it ranges from+40 ¡æ to -40 ¡æ.&lt;BR&gt;2. The altitude shall not exceed 2500m.&lt;BR&gt;3. The pollution level of the operating environment is Class 0, Class I or Class II in GB5582-85 &quot;Pollution Level of External Insulation of High Voltage Power Equipment&quot;.&lt;BR&gt;3. The installation site should be free from fire, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;Ordering Instructions&lt;BR&gt;1. Please indicate the product model and quantity when placing an order.&lt;BR&gt;2. If it is necessary to configure and assemble the connecting accessories with the operating mechanism, the model and quantity of the operating mechanism should be indicated.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]JSN(W)1 type anti misoperation mechanical program lock </title>
           <link>http://www.91way.com/info_en/2318.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:48:47</pubDate>
           <comments></comments>
           <description>JSN (W) 1 series anti misoperation mechanical program lock is a specialized mechanical lock for high-voltage switchgear. This lock forces operators to operate electrical equipment according to established safety operating procedures, thereby avoiding misoperation of electrical equipment and meeting the &quot;five prevention&quot; requirements relatively comprehensively. This product is equipped with a master key that can open any lock for non programmed operations such as live work after the equipment is shipped, debugged, or put into operation.&lt;BR&gt;&lt;BR&gt;The JSN (W) 1 anti misoperation mechanical program lock has the ability to distinguish between the opening and closing positions of each knife switch and the opening and closing position of the mesh door. And during operation, there is no need to switch keys one by one. Only one key is needed to complete multiple operations in a circuit according to the specified program. Due to the absence of a pin in the lock, it overcomes the inherent drawbacks of pin locks. This is a breakthrough and pioneering in China.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSN-DM type indoor electromagnetic lock </title>
           <link>http://www.91way.com/info_en/2317.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:48:37</pubDate>
           <comments></comments>
           <description>The DSN-DM indoor electromagnetic lock is suitable for indoor high-voltage electrical equipment with rated voltages of 3.6, 7.2, 12, 40.5kV and rated power of 50Hz. It is used in conjunction with sensors and has the function of reflecting the live status of the high-voltage circuit and achieving forced locking. Assembled in various switch cabinets, including the front and rear doors, as well as the parts that need to be locked, it can reliably prevent electrical misoperation, prevent accidental entry into live compartments, and effectively improve the anti misoperation performance of supporting products.&lt;BR&gt;&lt;BR&gt;DSN-DM indoor electromagnetic lock&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSN-M type indoor electromagnetic door lock </title>
           <link>http://www.91way.com/info_en/2316.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:48:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The DSN-M indoor electromagnetic door lock is an electrical control interlocking device that prevents electrical misoperation of high-voltage switchgear. It is mainly used to achieve forced interlocking of high-voltage switchgear doors and other places that require safety interlocking, to prevent accidental entry into live rooms. The surrounding air temperature is:&lt;BR&gt;Upper limit+40 ¡æ, lower limit -10 ¡æ, daily difference of 15 ¡æ&lt;BR&gt;Relative humidity conditions:&lt;BR&gt;Daily average not exceeding 95%&lt;BR&gt;Monthly average not exceeding 90%&lt;BR&gt;Environmental conditions:&lt;BR&gt;A place without fire, explosion hazard, severe dust, chemical corrosion, and severe vibration, with a pollution level of II.&lt;BR&gt;Altitude: not exceeding 1000m.&lt;BR&gt;&lt;BR&gt;Model and significance of DSN-M indoor electromagnetic door lock&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/2007526231657768.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 298px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of DSN-M Indoor Electromagnetic Door Lock&quot; src=&quot;/uploadfiles/200705/2007526231657768.jpg&quot; width=400 height=298&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Basic parameters of DSN-M indoor electromagnetic door lock&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200705/2007526231721414.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 110px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of DSN-M indoor electromagnetic door lock&quot; src=&quot;/uploadfiles/200705/2007526231721414.jpg&quot; width=680 height=110&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/2007526231731326.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 110px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;&quot; src=&quot;/uploadfiles/200705/2007526231731326.jpg&quot; width=680 height=110&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Note: The unlocking process involves pushing the moving iron core away from the lock bolt block to release the locked state. To unlock, the lock bolt must be moved with a knob or handle to achieve the purpose of unlocking. Therefore, the unlocking key cannot be used directly to unlock.&lt;BR&gt;&lt;BR&gt;The occurrence of isolation and misoperation is an indispensable locking device for power generation and supply departments.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSN type indoor electromagnetic switch mechanism </title>
           <link>http://www.91way.com/info_en/2315.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:48:19</pubDate>
           <comments></comments>
           <description>DSN type indoor electromagnetic switch mechanism is an electrical control interlocking device that prevents electrical misoperation of high-voltage switchgear. It is mainly used for indoor isolation switches with manual operation mechanisms to achieve electrical interlocking with circuit breakers and other places that require safety interlocking to achieve forced interlocking and prevent misoperation. It is an indispensable locking device for power generation and supply departments.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSW4G outdoor electromagnetic lock DSW4G-Z DSW4G-Y</title>
           <link>http://www.91way.com/info_en/2300.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:47:44</pubDate>
           <comments></comments>
           <description>&lt;P&gt;DSW4G-Z and DSW4G-Y outdoor electromagnetic locks are electrical mechanical interlocking devices for preventing misoperation of high-voltage isolation switch equipment with voltage levels of 10KV and above. They are mainly used to prevent misoperation between the isolation switch, grounding switch, and circuit breaker of the human operated mechanism.&lt;BR&gt;Product model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/200752085510979.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 218px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of DSW4G Outdoor Electromagnetic Lock&quot; src=&quot;/uploadfiles/200705/200752085510979.gif&quot; width=218 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Technical parameters&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/200752085528195.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 157px; WIDTH: 314px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of DSW4G outdoor electromagnetic lock&quot; src=&quot;/uploadfiles/200705/200752085528195.gif&quot; width=314 height=157&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Usage conditions&lt;BR&gt;1. The ambient temperature ranges from+40 ¡æ to -30 ¡æ, and in high-altitude regions, it ranges from+40 ¡æ to -40 ¡æ.&lt;BR&gt;2. The altitude shall not exceed 2500m.&lt;BR&gt;3. The pollution level of the operating environment is Class 0, Class I or Class II in GB5582-85 &quot;Pollution Level of External Insulation of High Voltage Power Equipment&quot;.&lt;BR&gt;3. The installation site should be free from fire, explosion hazards, chemical corrosion, and severe vibrations.&lt;BR&gt;Ordering Instructions&lt;BR&gt;1. Please indicate the product model and quantity when placing an order.&lt;BR&gt;2. If it is necessary to configure and assemble the connecting accessories with the operating mechanism, the model and quantity of the operating mechanism should be indicated. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSN3,JSN(W) series indoor electromagnetic lock and anti misoperation mechanical program lock </title>
           <link>http://www.91way.com/info_en/833.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:30:10</pubDate>
           <comments></comments>
           <description>JSN (W) 1 series anti misoperation mechanical program lock is a specialized mechanical lock for high-voltage switchgear. This lock forces operators to operate electrical equipment according to established safety procedures, thereby avoiding misoperation of electrical equipment and meeting the &quot;five prevention&quot; requirements relatively comprehensively. This product is equipped with a master key that can open any lock for non programmed operations such as live work after the equipment is shipped, debugged, or put into operation.&lt;BR&gt;This product has the ability to distinguish between the opening and closing positions of each knife switch and the opening and closing position of the mesh door. And during operation, there is no need to switch keys one by one. Only one key is needed to complete multiple operations in one circuit according to the specified program. Due to the absence of a pin in the lock, it overcomes the inherent drawbacks of pin locks. This is a breakthrough and pioneering in China.&lt;BR&gt;&lt;BR&gt;Environmental conditions for the use of DSN3, JSN (W) series indoor electromagnetic locks and anti misoperation mechanical program locks&lt;BR&gt;1. Altitude: not exceeding 1000m.&lt;BR&gt;2. Surrounding air temperature: upper limit+40 ¡æ, lower limit -10 ¡æ, daily temperature difference of 15 ¡æ.&lt;BR&gt;3. Humidity conditions: The average daily relative humidity should not exceed 95%; The average monthly relative humidity should not exceed 90%.&lt;BR&gt;4. Earthquake intensity: not exceeding 8 degrees.&lt;BR&gt;5. Environmental conditions: Places without fire, explosion hazards, severe dust, chemical corrosion, and severe vibration, with a pollution level of II.&lt;BR&gt;&lt;BR&gt;3¡¢ Model and its meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/20061111175613622.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 173px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DSN3, JSN (W) series indoor electromagnetic lock and anti misoperation mechanical program lock model description&quot; src=&quot;/uploadfiles/200611/20061111175613622.jpg&quot; width=500 height=173&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;4¡¢ Easy operation instructions&lt;BR&gt;1. Control switch lock&lt;BR&gt;Replace the original control switch panel and handle with a control switch lock. Insert the program key into the hole at the bottom of the lock panel, then insert the red card and turn the handle clockwise to close the switch. Replace the green card and turn the handle counterclockwise to open the switch. When in the pre opening position, the program key will not be removed. This lock has an emergency unlocking device (white plate)&lt;BR&gt;Attention: When the control switch is locked without a matching conversion switch, do not turn it 360 degrees to prevent damage. It can only be tested between merging and splitting.&lt;BR&gt;2. Knife Lock&lt;BR&gt;When opening the switch: Insert the key into the slot marked with the &quot;close&quot; character, turn the key clockwise to align the engraved line on the key. Pull out the locking pin and operate the isolation switch handle. After the switch is opened, the lock pin automatically resets, and the key continues to rotate clockwise into place. Remove the key from the slot marked with the &quot;open&quot; character to lock it. Align with the opening. &amp;nbsp;&lt;BR&gt;When closing the lock, insert the key into the slot marked with the word 'separation', and turn the key counterclockwise to align the engraved line on the key with the engraved line on the lock body. Pull out the locking pin and operate the isolation switch handle. After closing, the locking pin will automatically reset, and the key will continue to rotate counterclockwise into place. Pull out the key from the slot marked with the &quot;close&quot; character to lock it. Align with when closing.&lt;BR&gt;Attention: It is not allowed to operate the lock with both hands at the same time during operation (i.e. one hand operates the key and the other hand pulls the locking pin)&lt;BR&gt;3. Cabinet door lock&lt;BR&gt;When opening the door, insert the key into the lock hole of the mesh door lock, turn the key clockwise into place, and remove the key to open the mesh door. When closing the door, insert the key into the lock hole of the mesh door lock, close the door, turn the key counterclockwise into place, and remove the key to lock the mesh door. &amp;nbsp;&lt;BR&gt;Except for the control switch lock, each set of locks on other lock bodies has its own operation sequence number. Simply stamp 1, 2, 3, 4 (opening sequence) with a steel seal, and open the circuit in this order or close it in the order of 4, 3, 2, 1.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;5¡¢ Description of commonly used mechanical program locks&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Model Name&lt;/TD&gt;
&lt;TD align=center&gt;Lock configuration&lt;/TD&gt;
&lt;TD align=center&gt;Instructions for Use&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;202JS&lt;/TD&gt;
&lt;TD align=center&gt;Two identical single slot straight pull locks with one key&lt;/TD&gt;
&lt;TD align=center&gt;The dual input line scheme that cannot simultaneously deliver power is used.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;202JS(KK)&lt;/TD&gt;
&lt;TD align=center&gt;Two identical control switches locked with one key&lt;/TD&gt;
&lt;TD align=center&gt;The dual input line scheme that cannot simultaneously deliver power is used to control LW2.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;203JS&lt;/TD&gt;
&lt;TD align=center&gt;Three identical single slot straight pull locks and two keys&lt;/TD&gt;
&lt;TD align=center&gt;The one-time solution of dual power supply input and intermediate connection is used.&lt;BR&gt;Only two out of three switches can be put into use.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;203JS(KK)&lt;/TD&gt;
&lt;TD align=center&gt;Three identical control switches lock two keys&lt;/TD&gt;
&lt;TD align=center&gt;The one-time solution of dual power input and intermediate connection is used to control LW2.&lt;BR&gt;Only two out of three switches can be put into use.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;205JS&lt;/TD&gt;
&lt;TD align=center&gt;One straight pull lock and one mesh door lock&lt;/TD&gt;
&lt;TD align=center&gt;XGN2-12 switchgear dedicated, front and rear door interlocking&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;206JS&lt;/TD&gt;
&lt;TD align=center&gt;Always pull out the lock and add two mesh locks&lt;/TD&gt;
&lt;TD align=center&gt;Special for XGN2-12 switchgear, used for interlocking one front door and two rear doors.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;6¡¢ DSN3, JSN (W) series indoor electromagnetic lock and anti misoperation mechanical program lock ordering instructions&lt;BR&gt;1. Please specify the product model, specifications, and quantity.&lt;BR&gt;2. Provide a schematic diagram and interlocking requirements.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[electromagnetic lock]DSN3 type electromagnetic lock </title>
           <link>http://www.91way.com/info_en/831.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic lock</category>
           <pubDate>2026-6-13 18:29:52</pubDate>
           <comments></comments>
           <description>DSN3 indoor electromagnetic lock is an electrically controlled mechanical interlocking device that prevents electrical misoperation of high-voltage switchgear. Mainly used for indoor isolation switches of manually operated mechanisms to achieve electrical interlocking with circuit breakers, as well as interlocking with grid doors, high-voltage switchgear, and other places that require safety interlocking, to prevent accidental entry into live compartments and misoperation. It is an indispensable locking device for power generation and supply departments.&lt;BR&gt;This electromagnetic lock adopts an integral structural design, which is more reasonable than the DSN2 electromagnetic lock design. The structure is simpler, the layout is more compact, the lock volume is reduced, the functions are more comprehensive, the universality is good, and the operation is simple.&lt;BR&gt;The outstanding advantage is that the three voltage levels of DC110V, DC220V, and AC220V are universal, making it more convenient for users to order and use; Easy to install, no need to disassemble the panel, it can be inserted and installed as a whole.&lt;BR&gt;The DSN3 series electromagnetic lock has undergone formal testing by the Product Quality Inspection Center of Suzhou Institute of Technology, and all test data meets the requirements of JB/T7827-95 &quot;General Technical Conditions for Electromagnetic Locks for High Voltage Switchgear&quot;.&lt;BR&gt;Surrounding air temperature: upper limit+40 ¡æ; Lower limit -10 ¡æ, -25 ¡æ in high-altitude regions;&lt;BR&gt;Altitude: not exceeding 1000m.&lt;BR&gt;Environmental temperature: The daily average humidity should not exceed 95%, and the monthly average humidity should not exceed 90%.&lt;BR&gt;&lt;BR&gt;DSN3 indoor electromagnetic lock has the following performance:&lt;BR&gt;1. Equipped with an indicator light indicating whether unlocking is allowed;&lt;BR&gt;2. The lock bolt has automatic reset and delayed reset functions;&lt;BR&gt;3. Unlocking can be achieved with a dedicated key in the absence of electricity;&lt;BR&gt;4. A security device with the function of preventing easy tool unlocking and maintenance;&lt;BR&gt;5. Electromagnets can operate reliably at 85% -110% rated voltage.
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/2006103020371381.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 212px; WIDTH: 585px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of DSN3 Electromagnetic Lock&quot; src=&quot;/uploadfiles/200610/2006103020371381.jpg&quot; width=585 height=212&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061030203524207.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 241px; WIDTH: 227px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation diagram of DSN3 electromagnetic lock&quot; src=&quot;/uploadfiles/200610/20061030203524207.gif&quot; width=227 height=241&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;HEIGHT: 117px; WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; height=117 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; colSpan=2 align=center&gt;
&lt;DIV align=center&gt;name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=center&gt;
&lt;DIV align=center&gt;rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;Rated current mA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;DIV align=center&gt;Cabinet door opening (installation) size mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=center&gt;
&lt;DIV align=center&gt;Travel distance mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot; colSpan=2 align=center&gt;
&lt;DIV align=center&gt;switch lock&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-KZ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=101 rowSpan=6 width=&quot;13%&quot; align=center&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;
&lt;P align=center&gt;AC110&lt;/P&gt;
&lt;P align=center&gt;DC220&lt;/P&gt;
&lt;P align=center&gt;DC110&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=101 rowSpan=6 width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;
&lt;P align=center&gt;one hundred and ninety-six&lt;/P&gt;
&lt;P align=center&gt;ninety-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;32%&quot; align=center&gt;
&lt;DIV align=center&gt;Mechanism base locking pin screw hole M14 &#215; 1.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD height=101 rowSpan=6 width=&quot;12%&quot; align=center&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-KY&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;4%&quot; align=center&gt;
&lt;DIV align=center&gt;cabinet door lock&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot; align=center&gt;
&lt;DIV align=center&gt;Dial type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-AMZ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;32%&quot; align=center&gt;
&lt;DIV align=center&gt;56&#215;70 &amp;Oslash; 6&#215;82&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-AMY&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot; align=center&gt;
&lt;DIV align=center&gt;Handle type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-BMZ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot; align=center&gt;
&lt;DIV align=center&gt;DSN3-BMY&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200610/20061030203756629.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 295px; WIDTH: 584px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of DSN3 electromagnetic lock&quot; src=&quot;/uploadfiles/200610/20061030203756629.jpg&quot; width=584 height=295&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DSN3 type electromagnetic lock&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
