<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - 3KV current transformer</title>
       <link>http://www.91way.com</link>
       <description>3KV current transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:16:24</pubDate>
       <item>
           <title>[3KV current transformer]LMKZ-3.3KV Medium Voltage Current Transformer </title>
           <link>http://www.91way.com/info_en/19820.html</link>
           <author></author>
           <guid></guid>
           <category>3KV current transformer</category>
           <pubDate>2026-6-10 17:24:04</pubDate>
           <comments></comments>
           <description>LMKZ-3.3KV medium voltage current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[3KV current transformer]LMZ-1KV type mining current transformer </title>
           <link>http://www.91way.com/info_en/4876.html</link>
           <author></author>
           <guid></guid>
           <category>3KV current transformer</category>
           <pubDate>2026-6-10 17:23:56</pubDate>
           <comments></comments>
           <description>The LMZ-1KV mining current transformer is a busbar type, cast insulation, indoor type product, suitable for current measurement and relay protection in mining lines with a rated frequency of 50HZ and a rated voltage of 1KV and below.&lt;BR&gt;&lt;BR&gt;Normal working conditions and installation conditions&lt;BR&gt;1. The altitude of the installation site shall not exceed 1000m;&lt;BR&gt;2. The ambient air temperature does not exceed+40. C£¬ And its average temperature value within 24 hours does not exceed+35. C£¬ The lower limit of ambient air temperature is -5. C;&lt;BR&gt;3. The highest temperature is+40. At C, the relative humidity of the air does not exceed 50%; Higher relative humidity is allowed at lower temperatures, up to a maximum of 80%;&lt;BR&gt;4. Installed in non explosive and flammable hazardous media, with no gas or dust (including conductive dust) in the medium that can corrode metals and damage insulation;&lt;BR&gt;5. The installation location should have no severe vibrations or bumps, and the installation inclination should not exceed 5 &#176;;&lt;BR&gt;6. The installation location is not directly exposed to sunlight, and there is no rain, snow, or severe mold present.&lt;BR&gt;The structural features of this type of transformer are cast insulated busbar type, with a secondary winding wound on the iron core and a base at the bottom for fixed installation.&lt;BR&gt;&lt;BR&gt;Main technical parameters of LMZ-1KV mining current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Product model&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Rated primary current&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Rated secondary current&lt;/TD&gt;
&lt;TD colSpan=2&gt;Accuracy level and rated output&lt;BR&gt;COS¦Õ=0.8&lt;/TD&gt;
&lt;TD rowSpan=2&gt;number of turns through the core&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Rated insulation level&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=14&gt;LMZ-1&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD rowSpan=7&gt;five&lt;/TD&gt;
&lt;TD rowSpan=14&gt;&lt;/TD&gt;
&lt;TD rowSpan=7&gt;two&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD rowSpan=14&gt;1/3.6&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD rowSpan=7&gt;one&lt;/TD&gt;
&lt;TD rowSpan=7&gt;five&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;LMZ-1KV mining current transformer&lt;BR&gt;&lt;/P&gt;</description>