           <title>[Time-controlled switch]NKG-3 Time controlled switch </title>
           <link>http://www.91way.com/info_en/25007.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:45:52</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201404/20140424192022355.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 530px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of NKG-3 time control switch&quot; src=&quot;/upload2014/201404/20140424192022355.jpg&quot; width=680 height=530&gt;&lt;/A&gt;&lt;BR&gt;NKG-3 time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]KG-10 microcomputer conversion switch </title>
           <link>http://www.91way.com/info_en/23219.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:24:13</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;model&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;KG-10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;power supply voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;220VAC 50-60HZ &#177;15%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Internal battery voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;3.6VDC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Electricity consumption&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;About 1.5VA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;controlled output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;25A 250VAC (resistive load)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;display output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;LCD display&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Travel time error&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Less than 1 second per day&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;switching times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Daily/weekly cycle 10&lt;FONT face=Verdana&gt;sixteen&lt;/FONT&gt;Secondary switch&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;ambient temperature&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;-25 ¡æ to 60 ¡æ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;ambient humidity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;45 to 85% RH&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;At least 3000000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Weight and size&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;About 410 grams, 120 &#215; 74 &#215; 52mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Installation method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot; align=center&gt;
&lt;P align=center&gt;Installation type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=7 align=center&gt;Comparison Table of Sunday Signs in Chinese and English&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;MO&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;TU&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;WE&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;TH&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;FR&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;SA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;SU&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Monday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Tuesday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Wednesday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Thursday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Friday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Saturday&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Sunday&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;KG-10 microcomputer conversion switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JF-T02 microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/23078.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:23:07</pubDate>
           <comments></comments>
           <description>JF-T02 microcomputer time control switch&lt;BR&gt;Technical parameters:&lt;BR&gt;Execution standard: GB/T14536.1-1998 GB/T14536. 8-1996&lt;BR&gt;Rated voltage: 220V~50Hz&lt;BR&gt;Rated current: JF-T02 type 10A (resistive)&lt;BR&gt;JF-T03 type 16A (resistive)&lt;BR&gt;Working temperature: -20~70 ¡æ&lt;BR&gt;Timing error: ¡Ü&#177; 1 second/day&lt;BR&gt;3¡¢ System Function Introduction:&lt;BR&gt;1. LCD full screen characters, as shown in the figure on the right:&lt;BR&gt;2. When the machine is in clock mode, press the &quot;Mode&quot; button to set the working state to the desired mode.&lt;BR&gt;The setting sequence is: off ¡ú automatic ¡ú on ¡ú loop ¡ú Zz (countdown)&lt;BR&gt;Off - The power output is frequently turned off.&lt;BR&gt;Automatic - The power output is in the timed on/off program state set by the row code.&lt;BR&gt;On - The power output is frequently turned on.&lt;BR&gt;Cycle - The power output works in a cycle according to the length of the on time and interval time (off time) you set.&lt;BR&gt;Zz - The power output is in a countdown (delayed shutdown) state, with a maximum duration of 23 hours and 59 minutes and a minimum duration of 1 minute.&lt;BR&gt;C - Pressing this key will clear all stored data and restore the system to its initial state.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JFT16 microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/23077.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:13:35</pubDate>
           <comments></comments>
           <description>The JFT16 microcomputer time control switch can automatically turn on and off the power of various electrical devices according to the user's set time. The controlled objects can be streetlights, neon lights, advertising sign lights, production settings, broadcasting and television equipment, and all circuit devices and household appliances that need to be turned on and off at regular intervals.&lt;BR&gt;&lt;BR&gt;JFT16 microcomputer time control switch performance indicators&lt;BR&gt;1. Working voltage 220V/50Hz&lt;BR&gt;2. Applicable voltage range: 160V~240V&lt;BR&gt;3. Switch capacity resistive 25A, inductive 20A&lt;BR&gt;4. Power consumption&amp;lt;1W&lt;BR&gt;5. Not affected by power outages, internal automatic charging&lt;BR&gt;6. Up to 10 times a day can be set for manual and automatic use, with a maximum of 10 times for opening and closing&lt;BR&gt;7. The switch time can be cycled daily or weekly&lt;BR&gt;8. The longest control time is 168 hours and the shortest control time is 1 minute&lt;BR&gt;9. Environmental temperature -20~60 ¡æ&lt;BR&gt;10. The timing error is less than 0.5 seconds per day&lt;BR&gt;11. Environmental humidity&amp;lt;95%&lt;BR&gt;12. Net weight 430g&lt;BR&gt;&lt;BR&gt;Operating instructions&lt;BR&gt;1¡¢ Timer setting&lt;BR&gt;When users read the manual, please recognize the buttons on the product panel and operate them while reading.&lt;BR&gt;Section 1, Clock Adjustment: (If it needs to be readjusted after leaving the factory) Press and hold the &quot;Clock&quot; button while pressing the &quot;Week Calibration&quot; button, &quot;Time Calibration&quot; button, and &quot;Minute Calibration&quot; button. Section 2, Setting the First Start: Press the &quot;Timer&quot; button once, the LCD screen will appear (as shown in Figure 1), then press the &quot;Timing&quot; and &quot;Calibration&quot; buttons to enter the first start time.&lt;BR&gt;Section 3, Set the First Shutdown: Press the &quot;Timer&quot; and &quot;Calibration&quot; keys again to enter the first shutdown time.&lt;BR&gt;Section 4: Continue pressing the &quot;timer&quot; button, and the lower left corner of the display screen will sequentially display (2 on 2 off... 6 on 6 off... 10 on 10 off). Refer to steps 2 and 3 to set the time for each subsequent opening and closing. If you only open or close once a day, you must press the &quot;cancel/restore&quot; button to completely erase the storage time of (2 on 2 off... 6 on 6 off... 10 on 10 off), and display the &quot;--: --&quot; pattern on the LCD screen.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]KG316T-6 Microcomputer six output time control switch </title>
           <link>http://www.91way.com/info_en/23076.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:13:27</pubDate>
           <comments></comments>
           <description>KG316T-6 microcomputer six channel output time control switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]TB118,TB178 Time controlled switch </title>
           <link>http://www.91way.com/info_en/23075.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:13:19</pubDate>
           <comments></comments>
           <description>TB118, TB178 time control switch precautions&lt;BR&gt;&lt;BR&gt;Do not use in the following situations.&lt;BR&gt;Otherwise, it may become a cause of misoperation, malfunction, or leakage.&lt;BR&gt;-Places below 10 ¡æ or above+50 ¡æ&lt;BR&gt;Outdoor places that are directly exposed to rain or sunlight&lt;BR&gt;The place where dew condenses&lt;BR&gt;Places with corrosive gases such as sulfite gas or ammonia gas&lt;BR&gt;Places with heavy humidity or high dust content&lt;BR&gt;Places where vibration or impact occurs&lt;BR&gt;Places where vibration or impact occurs&lt;BR&gt;Places with strong high-frequency clutter, electric and magnetic fields&lt;BR&gt;The composition of the output circuit is the same circuit type (with voltage contact output).&lt;BR&gt;The output voltage on the output terminal is the same as the power supply voltage.&lt;BR&gt;Please do not confuse the power terminal with the output terminal.&lt;BR&gt;Otherwise, it will become the cause of load circuit breakage, misoperation, and malfunction.&lt;BR&gt;In situations where the load capacity exceeds the rated load, or where the load is a three-phase load, please use equipment such as electromagnetic contactors.&lt;BR&gt;After the construction is completed, please fully confirm the correctness of the wiring before connecting the main power supply for trial operation.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]Quartz time controlled switch </title>
           <link>http://www.91way.com/info_en/23074.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:13:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The SDK-2/3 quartz time control switch is made by introducing advanced foreign technology and using imported quartz resonators and CMOS electronic components. It has precise timing, stable and reliable operation, and is a new product in automatic timing control instruments in recent years. In recent years, this product has been sold throughout the country and is highly welcomed by users. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The SDK-2/3 quartz time controlled switch can be used directly or in conjunction with AC contactors to automatically switch single-phase or three-phase circuits for user control of various electrical appliances. It is suitable for street lamps, neon lights, advertising light boxes, electric bells, ovens, electric furnace bellows, power supply department peak electricity, and automation equipment. It can be used for user automatic tripping and closing, as well as automatic opening of the supply function for the public.&lt;BR&gt;&lt;BR&gt;Main technical indicators&lt;BR&gt;1. Travel time accuracy ¡Ü 1 second/day;&lt;BR&gt;2. Time control accuracy ¡Ü &#177; 5 points;&lt;BR&gt;3. The minimum switch period is 1.5 hours; The longest switch period is 24 hours;&lt;BR&gt;4. The operating environment temperature ranges from -20 ¡æ to+50 ¡æ;&lt;BR&gt;5. Contact rated voltage AC 100V, 220V, 380V;&lt;BR&gt;6. Contact rated current (resistive) AC 100V 7.5A, 220V 5A, 380V 2A;&lt;BR&gt;7. Quartz clock power supply DC 1.5V;&lt;BR&gt;8. Dimensions: 190 &#215; 143 &#215; 75mm&lt;BR&gt;&lt;BR&gt;Usage&lt;BR&gt;1. Loosen the regulator screws and fix the regulator on the clock face plate as needed. A pair of regulators form an open/close control period, and 1-2 open/close periods need to be controlled every day. Fix 1-2 pairs of regulators on the clock face plate, and after fixing them, the excess regulators must be unscrewed to control the time starting at that time. For example, to control the street lights, turn them on at 7 pm that night and turn them off at 5 am the next morning. Fix the black regulator at the 7:00 pm mark and the red regulator at the 5:00 am mark. He automatically turns off and on the power supply at the set time every day.&lt;BR&gt;2. Rotate the clock face clockwise (strictly prohibited from reversing), first place the regulator indicating the starting control time on the upper right side of the black indicator needle, then control the counterclockwise movement of the hexagonal cam (strict standard reverse movement) to make the clock switch outside the state before it needs to be opened or closed, and make one tooth in the hexagonal cam match the position indicated by the black indicator needle (at this time, the adjusting screw should just move the hexagonal cam to make the clock switch in the starting on/off state). When the starting control time is reached, install the 1.5V battery into the battery box, and the quartz clock will start working.&lt;BR&gt;&lt;BR&gt;Precautions for use&lt;BR&gt;1. The polarity of the 1.5V battery used in quartz clocks should not be reversed and should be replaced regularly. Typically, one high-performance No.1 battery can last for one year.&lt;BR&gt;2. It is strictly prohibited to reverse the dial and hexagonal cam of the clock, otherwise it may damage the components.&lt;BR&gt;3. After a long period of use, it should be readjusted to eliminate accumulated errors.&lt;BR&gt;4. The installation location should avoid exposure to direct sunlight, cold, strong magnetic fields, corrosive gases, or environments with relative humidity not exceeding 85%.&lt;BR&gt;5. The rated current value indicated on this product refers to resistive loads. If used for inductive loads such as high-power motors, it must be matched with AC contactors.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319081100599.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 184px&quot; border=0 hspace=0 alt=&quot;SDK-2/3 quartz time control switch wiring diagram&quot; src=&quot;/upload2013/201303/20130319081100599.jpg&quot; width=400 height=184&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319081106779.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 175px&quot; border=0 hspace=0 alt=&quot;Schematic diagram of SDK-2/3 quartz time control switch structure&quot; src=&quot;/upload2013/201303/20130319081106779.jpg&quot; width=200 height=175&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SDK-2/3 quartz time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]TB10A(TB1025) microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/23073.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:13:02</pubDate>
           <comments></comments>
           <description>The TB10A (TB1025) microcomputer time control switch adopts PJ-62 timing module, which can automatically turn on and off the power of various electrical equipment according to the user's set time. Widely used for programming, timing, and automatic control of electrical equipment in fields such as street lamps, neon lights, advertising lights, rice cookers, aerators, sprinklers, preheating and pre cooling devices, etc.&lt;BR&gt;&lt;BR&gt;2¡¢ The screen display conforms to the explanation&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;Rated voltage: 220V/50Hz&lt;BR&gt;Applicable voltage range: 160-240V&lt;BR&gt;Rated current: pure resistive load 30A, inductive load 20A&lt;BR&gt;Time control range: 1 minute to 168 hours&lt;BR&gt;Set frequency: 10 or 2 sets of programming scheduled per day (e.g. setting 9 o'clock on and 10 o'clock off is called 1 set of programming)&lt;BR&gt;Control cycle: can be controlled daily or weekly (can achieve different timing settings for each day within a week)&lt;BR&gt;Timing error:&amp;lt;&#177; 0.5 seconds/day&lt;BR&gt;Operating temperature: -30 ¡æ~60 ¡æ Strong moisture and dust resistance&lt;BR&gt;Installation method: three fixing methods: guide rail, suction wall, and hanging installation&lt;BR&gt;Dimensions: 115 &#215; 75 &#215; 52mm&lt;BR&gt;Wiring method: Lock type terminal wiring, in compliance with industrial standards.&lt;BR&gt;Timing method: 24-hour clock&lt;BR&gt;&lt;BR&gt;Keyboard lock, clock calibration, timing settings&lt;BR&gt;Long press the [Cancel/Resume] key for about 3 seconds to activate or deactivate the keyboard lock. &quot;&quot; represents the keyboard lock symbol. Clock calibration: Press and hold the [Clock] key, and simultaneously press the [Hour], [Minute], and [Week] keys to calibrate the clock and week.&lt;BR&gt;The timing setting steps are as follows:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;4%&quot;&gt;step&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;button&lt;/TD&gt;
&lt;TD width=&quot;72%&quot;&gt;Set project&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;Press the [Timer] key&lt;/TD&gt;
&lt;TD&gt;Enter the first set of timed on settings (display 1)&lt;SUP&gt;open&lt;/SUP&gt;£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;Press the [Week], [Hour], and [Minute] keys respectively&lt;/TD&gt;
&lt;TD&gt;Set opening time (week, hour, minute)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;Reinstall the [timer] button&lt;/TD&gt;
&lt;TD&gt;Enter the first set of timed off settings (display 1)&lt;SUB&gt;close&lt;/SUB&gt;£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;Press the [Week], [Hour], and [Minute] keys respectively&lt;/TD&gt;
&lt;TD&gt;Set the closing time (week, hour, minute)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;Repeat steps 1, 2, 3, and 4&lt;/TD&gt;
&lt;TD&gt;2-10 sets of switch times can be set&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;Press the [Timer] key continuously&lt;/TD&gt;
&lt;TD&gt;Check if the switch time and week of each group are as required. If they are incorrect, repeat steps 2 and 4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seven&lt;/TD&gt;
&lt;TD&gt;Press the [Auto/Manual] key&lt;/TD&gt;
&lt;TD&gt;Adjust the switch (&quot;¨‹&quot;) to the current state (&quot;on&quot; or &quot;off&quot;) and then return it to the &quot;automatic&quot; position&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;eight&lt;/TD&gt;
&lt;TD&gt;Press the [Clock] key&lt;/TD&gt;
&lt;TD&gt;Set the end time to enter the clock display state&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Note: If you do not need to set 10 groups, use the [Cancel/Restore] key to eliminate the excess number of groups. If &quot;--: --&quot; is displayed, it indicates elimination. Pressing the [Cancel/Restore] key again can restore the original time setting before elimination.&lt;BR&gt;Check: Press the [Timer] key continuously to check if the set time and week for each group are correct.&lt;BR&gt;Manual control: Press the [Manual/Auto] button to directly turn on or off the power. When not in the &quot;on&quot; state, keep it on; when in the &quot;off&quot; state, keep it off; When in the &quot;direct action&quot; state, the direct action executes the set time program.&lt;BR&gt;Pressing the [Clock] key or not pressing any key for 30 seconds in a non clock display state can restore the current settings to the clock display state.&lt;BR&gt;If you need a daily control cycle, please make sure to set the scheduled time (on and off) to the full display state of the week. As shown in the picture:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319075613362.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 55px&quot; border=0 hspace=0 alt=&quot;TB10A (TB1025) microcomputer time control switch panel setting&quot; src=&quot;/upload2013/201303/20130319075613362.jpg&quot; width=250 height=55&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;wiring diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319075558147.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 96px&quot; border=0 hspace=0 alt=&quot;TB10A (TB1025) Microcomputer Time Control Switch Wiring Diagram&quot; src=&quot;/upload2013/201303/20130319075558147.jpg&quot; width=300 height=96&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Product execution standard: GB14048.3-93&lt;BR&gt;Precautions&lt;BR&gt;If the display screen shows weakening, please replace the battery; If the setting content disappears, it needs to be reset.&lt;BR&gt;Please do not repair, disassemble or modify this product by yourself.&lt;BR&gt;Do not let this product come into contact with oil or water.&lt;BR&gt;This product only requires one 1.5V battery for power supply (front mounted, easy to replace), and the empty space of the other battery is reserved for battery replacement, which can prevent power loss and program loss.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]KG316YG(TB10 microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/23071.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:12:45</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The KG316YG (TB10 type) microcomputer time control switch can automatically turn on and off the power of various electrical equipment according to the user's set time. The controlled objects can be streetlights, neon lights, advertising signs, production equipment, broadcasting and television equipment, and all other circuit devices and household appliances that need to be turned on and off at regular intervals.&lt;BR&gt;&lt;BR&gt;performance metrics&lt;BR&gt;Standard working power supply 220V/50Hz&lt;BR&gt;Applicable voltage range: 160V~240V&lt;BR&gt;Switching Capacity Resistance 25A&lt;BR&gt;Power consumption&amp;lt;4W&lt;BR&gt;Time control range: 1 minute to 168 hours&lt;BR&gt;Environmental temperature -10~50 ¡æ&lt;BR&gt;Timing error&amp;lt;&#177; 2 seconds/day&lt;BR&gt;Environmental humidity&amp;lt;95%&lt;BR&gt;Dimensions 126 &#215; 88 &#215; 51mm&lt;BR&gt;Weight 510g&lt;BR&gt;There are 10 sets of switch times, which can be used manually or automatically;&lt;BR&gt;&lt;BR&gt;Operating instructions&lt;BR&gt;1. First, check if the clock display is consistent with the current time. If recalibration is required, while holding down the &quot;Clock&quot; button, press and hold the &quot;Calibrate Week&quot;, &quot;Calibrate Time&quot;, and &quot;Calibrate Minute&quot; buttons respectively to adjust the clock to the current accurate time:&lt;BR&gt;2. Press the &quot;timer&quot; button once, and the word &quot;1 on&quot; will appear at the bottom left of the display screen (indicating the first time it was turned on). Then press &quot;School Week&quot; to select work modes such as six day work system, five-day work system, three-day work system, daily same, daily different, etc., and then press the &quot;School Hour&quot; and &quot;School Minute&quot; keys to enter the desired start time;&lt;BR&gt;3. Press the &quot;timer&quot; button again, and the word &quot;1 off&quot; will appear at the bottom left of the display screen (indicating the first time it was turned off). Then press the &quot;school week&quot;, &quot;school hour&quot;, and &quot;school minute&quot; buttons, and enter the desired date and time for turning off (note: the date of turning off must correspond to the date of turning on);&lt;BR&gt;4. Continue pressing the &quot;timer&quot; button, and the lower left corner of the display screen will show &quot;2 on, 2 off, 3 on, 3 off,..., 10 on, 10 off&quot; in sequence. Refer to steps 2 and 3 to set the switch time for each subsequent switch;&lt;BR&gt;5. If 10 sets of switches do not need to be set every day, the &quot;Cancel/Restore&quot; button must be pressed to eliminate the excess time of each set and display the &quot;--: --&quot; pattern on the display screen (not 00:00);&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319074245429.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 92px&quot; border=0 hspace=0 alt=&quot;KG316YG (TB10 type) microcomputer time control switch setting schematic diagram&quot; src=&quot;/upload2013/201303/20130319074245429.jpg&quot; width=300 height=92&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;KG316YG (TB10 type) microcomputer time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JF-TGK01 type microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/23070.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:12:36</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JF-TGK01 series microcomputer time control switch is a highly integrated electronic switch device used for power switch program control. It can set one output to control 8 different time switches (or two outputs can simultaneously turn on or off the power, or alternately turn on or off the power, with a total of 16 different on/off control programs), and can set on/off control programs within one week. This machine has a memory function, which can maintain the time display and the original set product of various control programs for more than 6 months even when disconnected from the mains power supply. It can control various electrical devices that require time control, such as street lamps, billboards, light boxes, radio and television equipment, garden irrigation equipment, lighting in breeding farms and yards, lighting in tourist attractions, household appliances, etc. It is a safe and reliable electronic switch that is controlled by weak electricity, and is new and intelligent. For example, when used in conjunction with AC contactors, it can control three-phase high-power electrical equipment.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;Execution standard: GB/T1436. 1-1998£»&lt;BR&gt;GB/T1453.8-1998£»&lt;BR&gt;Rated voltage: 220V-50HZ&lt;BR&gt;Rated current: 20A (resistive)&lt;BR&gt;Working temperature: -10 ¡æ~55 ¡æ&lt;BR&gt;Timing error:&amp;lt;&#177; seconds/day&lt;BR&gt;&lt;BR&gt;Introduction to System Functions&lt;BR&gt;A¡¢ The time control switch has 7 operation keys: week, hour, minute, unlock, clock, setting, and mode;&lt;BR&gt;B¡¢ The full screen characters and external dimensions of the LCD are shown in Figure 1;&lt;BR&gt;C¡¢ Pressing the &quot;Mode&quot; button in the time display state of this machine can set the working state to the desired mode, and the setting order is:&lt;BR&gt;(Note: To unlock, press the &quot;unlock&quot; button four times in a row.)&lt;BR&gt;OFF Auto ON&lt;BR&gt;OFF - Power output, in the off state.&lt;BR&gt;Auto power output, in the off state.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130319074035538.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 180px; HEIGHT: 132px&quot; border=0 hspace=0 alt=&quot;Schematic diagram of JF-TGK01 microcomputer time control switch panel&quot; src=&quot;/upload2013/201303/20130319074035538.jpg&quot; width=180 height=132&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JF-TGK01 microcomputer time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]TB-10 microcomputer time control switch (optical time control) </title>
           <link>http://www.91way.com/info_en/23063.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 10:12:28</pubDate>
           <comments></comments>
           <description>The TB-10 microcomputer time control switch (light time control) can automatically turn on and off the power of various electrical equipment according to the user's set time. The controlled objects can be streetlights, neon lights, advertising signs, production equipment, broadcasting and television equipment, and all other circuit devices and household appliances that need to be turned on and off at regular intervals.&lt;BR&gt;&lt;BR&gt;performance metrics&lt;BR&gt;Standard working power supply 220V/50Hz&lt;BR&gt;Applicable voltage range: 160V~240V&lt;BR&gt;Switching Capacity Resistance 25A&lt;BR&gt;Power consumption&amp;lt;4W&lt;BR&gt;Time control range: 1 minute to 168 hours&lt;BR&gt;Environmental temperature -10~50 ¡æ&lt;BR&gt;Timing error&amp;lt;&#177; 2 seconds/day&lt;BR&gt;Environmental humidity&amp;lt;95%&lt;BR&gt;Dimensions 126 &#215; 88 &#215; 51mm&lt;BR&gt;Weight 510g&lt;BR&gt;There are 10 sets of switch times, which can be used manually or automatically;&lt;BR&gt;&lt;BR&gt;Operation Instructions for TB-10 Microcomputer Time Control Switch (Light Time Control)&lt;BR&gt;1. First, check if the clock display is consistent with the current time. If recalibration is required, while holding down the &quot;Clock&quot; button, press and hold the &quot;Calibrate Week&quot;, &quot;Calibrate Time&quot;, and &quot;Calibrate Minute&quot; buttons respectively to adjust the clock to the current accurate time:&lt;BR&gt;2. Press the &quot;timer&quot; button once, and the word &quot;1 on&quot; will appear at the bottom left of the display screen (indicating the first time it was turned on). Then press &quot;School Week&quot; to select work modes such as six day work system, five-day work system, three-day work system, daily same, daily different, etc., and then press the &quot;School Hour&quot; and &quot;School Minute&quot; keys to enter the desired start time;&lt;BR&gt;3. Press the &quot;timer&quot; button again, and the word &quot;1 off&quot; will appear at the bottom left of the display screen (indicating the first time it was turned off). Then press the &quot;school week&quot;, &quot;school hour&quot;, and &quot;school minute&quot; buttons, and enter the desired date and time for turning off (note: the date of turning off must correspond to the date of turning on);&lt;BR&gt;4. Continue pressing the &quot;timer&quot; button, and the lower left corner of the display screen will show &quot;2 on, 2 off, 3 on, 3 off,..., 10 on, 10 off&quot; in sequence. Refer to steps 2 and 3 to set the switch time for each subsequent switch;&lt;BR&gt;5. If 10 sets of switches do not need to be set every day, the &quot;Cancel/Restore&quot; button must be pressed to eliminate the excess time of each set and display the &quot;--: --&quot; pattern on the display screen (not 00:00);</description>
       </item>
       <item>
           <title>[Time-controlled switch]SGKII-2 Sound light controlled delay switch </title>
           <link>http://www.91way.com/info_en/19983.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:55:32</pubDate>
           <comments></comments>
           <description>SGKII-2 sound light control delay switch&lt;BR&gt;&lt;BR&gt;Working voltage: 160-250V AC&lt;BR&gt;Light control sensitivity:&amp;gt;1-4Lx off&lt;BR&gt;Static current:&amp;lt;2mA (annual power consumption&amp;lt;0.3 kWh)&lt;BR&gt;Environmental temperature: -25 ¡æ -55 ¡æ&lt;BR&gt;Control power: ¡Ü 60W&lt;BR&gt;Delay time: 60 seconds &#177; 30% or user selectable&lt;BR&gt;Voice control sensitivity: 65-70db&lt;BR&gt;Control load: resistive (incandescent lamp)&lt;BR&gt;Emergency control: None&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;Specification Model&lt;/TD&gt;
&lt;TD&gt;terminal&lt;/TD&gt;
&lt;TD&gt;Emergency control&lt;/TD&gt;
&lt;TD&gt;neutral wire&lt;/TD&gt;
&lt;TD&gt;power control&lt;/TD&gt;
&lt;TD&gt;load type&lt;/TD&gt;
&lt;TD&gt;explanation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;SGKI-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;SGKI-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;discontinue production&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;SGKII-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;SGKII-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;two&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-1&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;60X40X23 millimeter&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;60 millimeters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-2&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;70X45X28mm&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;47.5 millimeters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKII-2&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;86X86X25mm&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;60 millimeters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKII-3&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;110X85X25mm&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;80 millimeters&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SGKII-2 sound light control delay switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]SGKI-1 Sound light controlled delay switch </title>
           <link>http://www.91way.com/info_en/19982.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:55:24</pubDate>
           <comments></comments>
           <description>Working voltage: 160-250V AC&lt;BR&gt;Light control sensitivity:&amp;gt;1-4Lx off&lt;BR&gt;Static current:&amp;lt;2mA (annual power consumption&amp;lt;0.3 kWh)&lt;BR&gt;Environmental temperature: -25 ¡æ -55 ¡æ&lt;BR&gt;Control power: ¡Ü 60W&lt;BR&gt;Delay time: 60 seconds &#177; 30% or user selectable&lt;BR&gt;Voice control sensitivity: 65-70db&lt;BR&gt;Control load: resistive (incandescent lamp)&lt;BR&gt;Emergency control: None&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;Specification Model&lt;/TD&gt;
&lt;TD&gt;terminal&lt;/TD&gt;
&lt;TD&gt;Emergency control&lt;/TD&gt;
&lt;TD&gt;neutral wire&lt;/TD&gt;
&lt;TD&gt;power control&lt;/TD&gt;
&lt;TD&gt;load type&lt;/TD&gt;
&lt;TD&gt;explanation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;SGKI-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-1&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;60X40X23mm&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;60 millimeters&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SGKI-1 sound light control delay switch&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]SGKI-3 series sound light controlled delay switch </title>
           <link>http://www.91way.com/info_en/19981.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:55:15</pubDate>
           <comments></comments>
           <description>Working voltage: 160-250V AC&lt;BR&gt;Light control sensitivity:&amp;gt;1-4Lx off&lt;BR&gt;Static current:&amp;lt;2mA (annual power consumption&amp;lt;0.3 kWh)&lt;BR&gt;Environmental temperature: -25 ¡æ -55 ¡æ&lt;BR&gt;Control power: ¡Ü 60W (ordinary type) ¡Ü 200W (special type)&lt;BR&gt;Delay time: 60 seconds &#177; 30% or user selectable&lt;BR&gt;Voice control sensitivity: 65-70db&lt;BR&gt;Control load: resistive (incandescent lamp)/energy-saving lamp (special supply type)&lt;BR&gt;Emergency control: optional&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=143&gt;Specification Model&lt;/TD&gt;
&lt;TD width=74&gt;terminal&lt;/TD&gt;
&lt;TD width=98&gt;Emergency control&lt;/TD&gt;
&lt;TD width=52&gt;neutral wire&lt;/TD&gt;
&lt;TD width=96&gt;power control&lt;/TD&gt;
&lt;TD width=159&gt;load type&lt;/TD&gt;
&lt;TD width=54&gt;explanation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-3&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD height=23 align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-3/E&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;
&lt;TD align=middle&gt;Strong cutting type&lt;/TD&gt;
&lt;TD height=23 align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;60W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-3/D&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;200W&lt;/TD&gt;
&lt;TD align=middle&gt;Incandescent/fluorescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;custom-made&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SGKI-3/ED&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;
&lt;TD align=middle&gt;Strong cutting type&lt;/TD&gt;
&lt;TD height=23 align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;200W&lt;/TD&gt;
&lt;TD align=middle&gt;Incandescent/fluorescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;custom-made&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Vertical appearance dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P&gt;62x60x35mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;53 millimeters&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SGKI-3 series sound light control delay switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]CMY series touch delay switch </title>
           <link>http://www.91way.com/info_en/19971.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:54:50</pubDate>
           <comments></comments>
           <description>CMY series touch delay switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=88&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64&gt;terminal&lt;/TD&gt;
&lt;TD width=85&gt;Emergency control&lt;/TD&gt;
&lt;TD width=47&gt;neutral wire&lt;/TD&gt;
&lt;TD width=81&gt;power control&lt;/TD&gt;
&lt;TD width=108&gt;load type&lt;/TD&gt;
&lt;TD width=203&gt;explanation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W-100w&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/e&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;controlling&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;60W-100W&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/ET&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;
&lt;TD align=middle&gt;Strong cutting type&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;100-200w&lt;/TD&gt;
&lt;TD align=middle&gt;incandescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;Latest Patent&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü 200W&lt;/TD&gt;
&lt;TD align=middle&gt;Any load&lt;/TD&gt;
&lt;TD align=middle&gt;custom-made&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/ED&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;
&lt;TD align=middle&gt;Strong cutting type&lt;/TD&gt;
&lt;TD align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü 200W&lt;/TD&gt;
&lt;TD align=middle&gt;Incandescent/fluorescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;custom-made&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/ds&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü 120W&lt;/TD&gt;
&lt;TD align=middle&gt;Incandescent/fluorescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;Be sure to specify the type of load&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/EMd&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;
&lt;TD align=middle&gt;Strong cutting type&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü 200W&lt;/TD&gt;
&lt;TD align=middle&gt;Incandescent/fluorescent lamp&lt;/TD&gt;
&lt;TD align=middle&gt;Latest Special&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;
&lt;DIV align=center&gt;CMY-1/Dt&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;
&lt;TD align=middle&gt;nothing&lt;/TD&gt;
&lt;TD align=middle&gt;have&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü 200W&lt;/TD&gt;
&lt;TD align=middle&gt;Any load&lt;/TD&gt;
&lt;TD align=middle&gt;Sound and light control sensitivity, adjustable delay time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;
&lt;DIV align=center&gt;Overall Dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;86X86X25mm&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Fixed hole spacing&lt;/TD&gt;
&lt;TD align=middle&gt;60 millimeters&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CMY series touch delay switch&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JSK-2S microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/19969.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:54:33</pubDate>
           <comments></comments>
           <description>JSK-2S microcomputer time control switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;terminal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;power control&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;load type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;JSK-2S&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;2000W&lt;/TD&gt;
&lt;TD align=middle&gt;arbitrary&lt;/TD&gt;
&lt;TD align=middle&gt;AC220V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;JSK-2S (specially made)&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;According to voltage&lt;/TD&gt;
&lt;TD align=middle&gt;arbitrary&lt;/TD&gt;
&lt;TD align=middle&gt;12V 24V 110V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD align=middle&gt;96&#215;44&#215;53mm&lt;/TD&gt;
&lt;TD colSpan=3 align=middle&gt;Fixed method: rail type&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Standard working power supply: 220VAC/50Hz 12VDC 24VDC Timing error: £¼ &#177; 2 seconds/day&lt;BR&gt;Allowable power range: &#177; 10% Environmental temperature: -10~40 ¡æ&lt;BR&gt;Rated output voltage: Operating power supply voltage Rated load current: 10A&lt;BR&gt;Time control range: 1 minute to 168 hours. Keyboard automatic locking: available&lt;BR&gt;Switch adjustable frequency: 20 times/day (2012 latest model) Weight: 147g&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JXH-1 Loop timing controller </title>
           <link>http://www.91way.com/info_en/19968.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:54:25</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JXH-1 Loop Timing Controller&lt;/P&gt;
&lt;P&gt;1. Working voltage: 160-240vac or 12vdc, 24vdc (customized)&lt;BR&gt;3. Time setting range: 1 second to 23 hours, 59 minutes, and 59 seconds Working temperature: -20 &#176; C to+60 &#176; C&lt;BR&gt;4. Working mode: single timed on/off, single timed off/loop timed&lt;BR&gt;5. Working temperature: -25 &#176; C to+80 &#176; C&lt;BR&gt;6. Relative humidity&amp;lt;95%&lt;BR&gt;7. Timing error: &#177; 1 second/day&lt;BR&gt;8. Output control power: 3000w&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD&gt;Specification Model&lt;/TD&gt;
&lt;TD&gt;terminal&lt;/TD&gt;
&lt;TD&gt;power control&lt;/TD&gt;
&lt;TD&gt;load type&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;JXH-1&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;3000W&lt;/TD&gt;
&lt;TD align=middle&gt;arbitrary&lt;/TD&gt;
&lt;TD align=middle&gt;220VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Overall Dimensions&lt;/TD&gt;
&lt;TD align=middle&gt;125&#215;82&#215;68mm&lt;/TD&gt;
&lt;TD align=middle&gt;Fixed hole size&lt;/TD&gt;
&lt;TD align=middle&gt;68X122MM&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JXH-1 Loop Timing Controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]JSK-3 type microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/19964.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-14 9:54:16</pubDate>
           <comments></comments>
           <description>The JSK-3 microcomputer time control switch can automatically turn on and off the power of various electrical equipment according to the user's set time. The controlled objects can be street lamps, neon lights, advertising sign lights, production equipment, broadcasting and television equipment, and all electrical and household appliances that need to be turned on and off at regular intervals.&lt;BR&gt;&lt;BR&gt;JSK-3 microcomputer time control switch can be customized according to user requirements for 12V, 24V, 36V AC/DC working products. Conventional products do not have light controlled rain control probes, which can be installed according to requirements. The product model for installing light control probes is JSK-3/G, and the product model for installing rain control probes is JSK-3/Y.&lt;BR&gt;&lt;BR&gt;2¡¢ Main technical indicators:&lt;BR&gt;Applicable power range: 160-240VAC, 50/60/Hz Timing error: £¼ &#177; 2 seconds/day&lt;BR&gt;Single switch capacity: resistive 20A inductive 16A dual switch capacity: 2 &#215; 5A&lt;BR&gt;Relative humidity:&amp;lt;95% Environmental temperature: -10 to+60 ¡æ&lt;BR&gt;Time control range: 1 minute to 168 hours Power consumption:&amp;lt;1VA&lt;BR&gt;There are 10 sets of switch times, both manual and automatic. Weight: 365 grams&lt;BR&gt;&lt;BR&gt;3¡¢ Instructions for use:&lt;BR&gt;Clock status setting/adjustment:&lt;BR&gt;On the clock display interface, hold down the [Clock] key while pressing the [Hour], [Minute], or [Week] keys to adjust the clock or week; Press the [Auto/Manual] button to switch between [On/Auto/Off] states (when pressed to the &quot;On&quot; state, the system will always have output; when pressed to the &quot;Off&quot; state, the system will turn off the output; when pressed to the &quot;Auto&quot; state, the system will execute the set time switch program, and should be placed in the &quot;Auto&quot; position during normal operation).&lt;BR&gt;&#167; Timer state setting/adjustment:&lt;BR&gt;1. After unlocking the keyboard, press the [Timer] key to enter the timer state. Each time you press the [Timer] key, you will enter the next set of timer settings interface; The JSK-3A model does not have a keyboard lock, while the JSK-3B model has a keyboard lock. The time control switch has an automatic keyboard lock function. To start the operation, long press the &quot;unlock&quot; button for 3 seconds to make the lock icon in the bottom left corner of the screen disappear,&lt;BR&gt;If you press the [Timer] key continuously: 1 on ¡ú 1 off ¡ú 2 on ¡ú 2 off ¡ú... 9 on ¡ú 9 off ¡ú 10 on ¡ú 10 off ¡ú Clock interface ¡ú 1 on ¡ú 1 off ¡ú 2 on ¡ú 2 off ¡ú... Repeat the cycle. &amp;nbsp;&lt;BR&gt;2. On the timer setting interface, press the [Hour] key to adjust the hour for the current timer&lt;BR&gt;3. On the timer setting interface, press the [minute] key to adjust the minute of the current timer&lt;BR&gt;4. On the timer setting interface, press the [Week] key to adjust the week setting selection for the current timer; There are 15 week combination modes to choose from for each &quot;on&quot; or &quot;off&quot; setting. By continuously pressing the [week] key, the 15 week combination display can be cycled as follows:&lt;BR&gt;Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Saturday, Sunday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday, Friday. &amp;nbsp;&lt;BR&gt;5. In the timing setting interface, pressing the [Cancel/Restore] button will cancel or restore the set of timing. &amp;nbsp;&lt;BR&gt;6. On the timer setting interface, press the [Clock] key to return to the clock state.&lt;BR&gt;&lt;BR&gt;4¡¢ Instructions for using the light controlled rain control probe:&lt;BR&gt;On the right side of the product, there is a light rain control socket and a light intensity adjustment knob. When the light control probe and rain control probe are not plugged in, the usage method is the same as described earlier. &amp;nbsp;&lt;BR&gt;2. Instructions for using the light control: If the switch output is in the on state, plug in the light control probe (the light control plug above and the rain control socket below). If there is light, the light rain control indicator light will turn on and the switch will turn off after about 30 seconds; After no light, the indicator light will turn off, and it will be recognized and restored to its original state after about 30 seconds; If the switch output is in the off state, regardless of whether there is light, the switch will not operate and will remain in the off state.&lt;BR&gt;Adjusting the illuminance knob can change the starting illuminance. Turning it clockwise will decrease the illuminance (start when the light is dim), while turning it counterclockwise will increase the illuminance (start when the light is strong). When adjusting, simply observe the changes in the panel indicator light. When the illumination reaches the control illumination, adjust the knob to make the panel indicator light just turn off. Pay attention to waiting for 30 seconds for the output to change. It should be noted that after adopting light control, the time control switch must be set to on during the time period when light control is required. &amp;nbsp;&lt;BR&gt;3. Rain control usage method: Insert the rain control probe. If the switch output is in the on state, the probe will sense rainwater at this moment. After about 30 seconds of turning on, it will turn off. After about 30 seconds of no rainwater, it will recognize and restore the original state and turn on; If the switch output is in the off state, regardless of whether the probe senses rainwater or not, the switch will not operate and remain in the off state. &amp;nbsp;&lt;BR&gt;4. Simultaneous use of light control and rain control: In any state of light or rain, regardless of whether the switch is in the on or off state, after a delay of 30 seconds, the switch will enter the off state; If there is no light or rain, the timer switch will work according to the original set program. &amp;nbsp;&lt;BR&gt;5. Products with light and rain control function have about one minute of off state output when first turned on.&lt;BR&gt;&lt;BR&gt;5¡¢ Wiring method:&lt;BR&gt;1. Wiring for direct control mode&lt;BR&gt;The controlled electrical appliance is single-phase power supply, with power consumption not exceeding the rated capacity of this switch (25A resistive load, 20A inductive load), and can be directly controlled. The wiring method is shown in Figure 1.&lt;BR&gt;2. Wiring of single-phase expansion method&lt;BR&gt;The controlled electrical appliance is powered by single-phase power, but its power consumption exceeds the rated capacity of this switch (25A resistive load, 20A inductive load). Therefore, an AC contactor with a capacity exceeding the power consumption of the appliance is needed to expand its capacity. The wiring method is shown in Figure 2.&lt;BR&gt;3. Wiring of indirect control mode&lt;BR&gt;This controller is powered by single-phase AC or DC 12V (24V). If the controlled appliance is powered by three-phase, an external three-phase AC contactor is required. The coil voltage of the control contactor is the output voltage of this controller, and the wiring method is shown in Figure 3.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Specification Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=127&gt;
&lt;DIV align=center&gt;terminal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=145&gt;
&lt;DIV align=center&gt;power control&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;load type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=170 align=middle&gt;
&lt;DIV align=center&gt;explanation&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;JSK-3A&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3000W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;arbitrary&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;JSK-3 is an improved version of JSK-1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;
&lt;DIV align=center&gt;JSK-3B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2X600W (two channels)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;arbitrary&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;
&lt;DIV align=center&gt;Overall Dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;125 &#215; 82 &#215; 68 millimeters&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Fixed hole size&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;68X122 millimeters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT17-2a Two channel latitude and longitude time control switch </title>
           <link>http://www.91way.com/info_en/16483.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:15:11</pubDate>
           <comments></comments>
           <description>ZYT17-2a two-way latitude and longitude time control switch&lt;BR&gt;&lt;BR&gt;Timed range: Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;BR&gt;Working voltage AC220V/50Hz (other voltages can be customized according to user requirements)&lt;BR&gt;Working temperature -10 ¡æ~50 ¡æ&lt;BR&gt;Dimensions 100 &#215; 50 &#215; 74mm&lt;BR&gt;Switch capacity 8A/circuit&lt;BR&gt;Programmable 2 groups/route/day&lt;BR&gt;The battery is rechargeable and can be operated for 30 days during power outages&lt;BR&gt;Power consumption ¡Ü 5W&lt;BR&gt;Timing error ¡Ü 30 seconds/year (adjustable error automatically)&lt;BR&gt;Weight 180g&lt;BR&gt;Installation method: rail or wall mounted&lt;BR&gt;Safety Standard CQC&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT17 Longitude and latitude time control switch </title>
           <link>http://www.91way.com/info_en/16482.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:15:02</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;ZYT17 latitude and longitude time control switch&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Longitude and latitude time control switch&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing range&lt;/TD&gt;
&lt;TD align=center&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD align=center&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=center&gt;-10¡æ¡«50¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD align=center&gt;100&#215;50&#215;74mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD align=center&gt;8A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD align=center&gt;2 groups/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD align=center&gt;Rechargeable battery, 30 day power-off operation timer&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü5W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü 30 seconds/year (with automatic error adjustment)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD align=center&gt;175g&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD align=center&gt;Rail or wall mounted&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;
&lt;TD align=center&gt;CQC&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT17 latitude and longitude time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT16G-2a,3a Two (three) channel time control switch </title>
           <link>http://www.91way.com/info_en/16481.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:14:53</pubDate>
           <comments></comments>
           <description>ZYT16G-2a, 3a two (three) time control switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; collapse: &quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;ZYT16G-2a&lt;/TD&gt;
&lt;TD width=283 align=center&gt;ZYT16G-3a&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Two way time control switch&lt;/TD&gt;
&lt;TD align=center&gt;Three way time control switch&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99 align=center&gt;timing range&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;-10¡æ¡«50¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;120&#215;72&#215;50mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;8A/Road&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;8/10/16 groups/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;Battery No. 5, replaceable&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;¡Ü4W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;¡Ü 2 seconds/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;270g&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;Wall mounted guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;CQC&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT16G-2a, 3a two (three) time control switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT16 microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/16480.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:14:44</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;ZYT16&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Microcomputer time control switch&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing range&lt;/TD&gt;
&lt;TD align=center&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD align=center&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=center&gt;-10¡æ¡«50¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD align=center&gt;120&#215;74&#215;58mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD align=center&gt;25A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD align=center&gt;8/10/16 groups/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD align=center&gt;AA battery&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü4W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü 2 seconds/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD align=center&gt;230g&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD align=center&gt;wall-mounted&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;
&lt;TD align=center&gt;CQC&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT16 microcomputer time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT16G Microcomputer time control switch (improved version) </title>
           <link>http://www.91way.com/info_en/16479.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:14:34</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;ZYT16G&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Microcomputer time control switch (improved version)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing range&lt;/TD&gt;
&lt;TD align=center&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD align=center&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=center&gt;-10¡æ¡«50¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD align=center&gt;120&#215;72&#215;50mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD align=center&gt;25A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD align=center&gt;8/10/16 groups/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD align=center&gt;Battery No. 5, replaceable&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü4W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü 2 seconds/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD align=center&gt;210g&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD align=center&gt;Wall mounted panel with guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;
&lt;TD align=center&gt;CQC&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT16G microcomputer time control switch (improved version)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]ZYT01,ZYT01a Time controlled socket </title>
           <link>http://www.91way.com/info_en/16478.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:14:25</pubDate>
           <comments></comments>
           <description>ZYT01, ZYT01a time control socket can be a time control socket, with an internationally recognized socket design. The product can automatically turn on and off the power of various electrical devices according to the time set by the user. The control objects can be street lamps, neon lights, advertising sign lights, production equipment, broadcasting and television equipment, and all electrical appliances and household appliances that need to be turned on and off at regular intervals (such as water dispensers, rice cookers, washing machines, and other household appliances). It realizes intelligent switching of electrical appliances, meets your daily needs, is convenient and easy to use, and can save energy.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=126 align=center&gt;timing range&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;-10¡æ¡«50¡æ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;123&#215;60&#215;68mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;P align=left&gt;10A or 16A&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=center&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;8/10/16 groups/day&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;Battery No. 5, replaceable&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;¡Ü5W&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;¡Ü 2 seconds/day&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;140g&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=left&gt;Wall socket type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT01, ZYT01a time control socket&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]Enhanced Time Control Switch </title>
           <link>http://www.91way.com/info_en/16477.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 21:14:16</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;80%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;ZYT16Z Enhanced Time Control Switch&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Enhanced time control switch&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD borderColor=#fafafa align=center&gt;timing range&lt;/TD&gt;
&lt;TD align=center&gt;Cycle work according to the set program every week or day, 1 minute to 168 hours&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;working voltage&lt;/TD&gt;
&lt;TD align=center&gt;AC220V/50Hz (other voltages can be customized according to user requirements)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=center&gt;-10¡æ¡«50¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD align=center&gt;120&#215;72&#215;50mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;switch capacity&lt;/TD&gt;
&lt;TD align=center&gt;25A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Programmable numbers&lt;/TD&gt;
&lt;TD align=center&gt;8/10/16 groups/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Battery&lt;/TD&gt;
&lt;TD align=center&gt;Rechargeable battery, power outage timer for 30 days&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;power consumption&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü4W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;timing error&lt;/TD&gt;
&lt;TD align=center&gt;¡Ü 2 seconds/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Weight&lt;/TD&gt;
&lt;TD align=center&gt;270g&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Installation method&lt;/TD&gt;
&lt;TD align=center&gt;Wall mounted guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;safety standards&lt;/TD&gt;
&lt;TD align=center&gt;CQC&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZYT16Z Enhanced Time Control Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]KG-3 Microcomputer based optical time control switch </title>
           <link>http://www.91way.com/info_en/14725.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 19:56:39</pubDate>
           <comments></comments>
           <description>KG-3 microcomputer light time control switch features:&lt;BR&gt;&lt;BR&gt;1. Ideal energy-saving and prolonging the service life of lighting devices. It should be automatically turned on by light control during dark weather and automatically turned off by time control during dawn. This product combines light usage and is an ideal control product for street lamps, light boxes, and neon lights.&lt;BR&gt;2. The controller contains a delay circuit during operation (instantaneous illumination). Built in rechargeable battery, external battery switch, high-precision, industrial grade chip, strong anti-interference.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;model&lt;/TD&gt;
&lt;TD&gt;KG-3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power supply voltage&lt;/TD&gt;
&lt;TD&gt;220VAC 50~60HZ &#177;15%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Internal battery voltage&lt;/TD&gt;
&lt;TD&gt;1.2VDC/40MAH rechargeable battery&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electricity consumption&lt;/TD&gt;
&lt;TD&gt;¡Ü1.5VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;controlled output&lt;/TD&gt;
&lt;TD&gt;25A 250VAC (resistive load)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;display device&lt;/TD&gt;
&lt;TD&gt;LCD display&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Travel time error&lt;/TD&gt;
&lt;TD&gt;¡Ü 1 second/day&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;switching times&lt;/TD&gt;
&lt;TD&gt;Switch 1-16 times per day/week cycle&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ambient temperature&lt;/TD&gt;
&lt;TD&gt;-10¡æ~70¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ambient humidity&lt;/TD&gt;
&lt;TD&gt;45~85£¥RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;¡Ü 3000000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Weight size&lt;/TD&gt;
&lt;TD&gt;430 grams, 120 &#215; 74 &#215; 52mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Installation method&lt;/TD&gt;
&lt;TD&gt;Installation type&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;KG-3 microcomputer light time control switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]DHC20 series 24 hour controller </title>
           <link>http://www.91way.com/info_en/6522.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 19:40:54</pubDate>
           <comments></comments>
           <description>DHC20 series 24-hour time controller:&lt;BR&gt;&lt;BR&gt;DHC20 series 24-hour time controller features&lt;BR&gt;24-hour time controller with DIN standard size and DIN35mm standard rail installation&lt;BR&gt;Replace mechanical methods with electronic ones.&lt;BR&gt;15 minutes is the minimum set time, and the operation is very easy.&lt;BR&gt;24-hour clock display, LED backlight, illuminated during keyboard operation.&lt;BR&gt;Equipped with a built-in battery, it will continue to operate as usual after a power outage&lt;BR&gt;High precision, high reliability, with daylight saving time.&lt;BR&gt;patented product&lt;BR&gt;Compliant standards: Q/WDH03-2003, GB14048.5-2001, IEC60947-5-1:1997&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Time-controlled switch]KG316T microcomputer time control switch </title>
           <link>http://www.91way.com/info_en/2384.html</link>
           <author></author>
           <guid></guid>
           <category>Time-controlled switch</category>
           <pubDate>2026-6-13 18:48:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The KG316T time control switch can automatically turn on and off the power of various electrical equipment according to the user's set time. The controlled objects can be street lamps, neon lights, advertising sign lights, production equipment, broadcasting and television equipment, and all circuit devices and household appliances that need to be turned on and off at regular intervals. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Characteristics of KG316T microcomputer time control switch&lt;BR&gt;a¡¢ Directly control power up to 6kW&lt;BR&gt;b¡¢ Not afraid of power outages, internal automatic charging; &amp;nbsp;&lt;BR&gt;c¡¢ Up to 6-8 to 12 opening and closing actions can be set per day;&lt;BR&gt;d¡¢ The switch time can be cycled daily or weekly; &amp;nbsp;&lt;BR&gt;e¡¢ Equipped with keyboard lock function to prevent accidental operation;&lt;BR&gt;f¡¢ All use single key operation, easy to install and debug;&lt;BR&gt;g¡¢ The daily walking time error is less than 0.5 seconds.&lt;BR&gt;&lt;BR&gt;Main technical data of KG316T microcomputer time control switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200708/20078383536550.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 113px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of KG316T microcomputer time control switch&quot; src=&quot;/uploadfiles/200708/20078383536550.gif&quot; width=500 height=113&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Wiring method&lt;BR&gt;1. Wiring for direct control mode&lt;BR&gt;The controlled electrical appliances are single-phase power supply, with power consumption not exceeding the rated value of this switch (resistive load not exceeding 25A, inductive load not exceeding 20A), and can be directly controlled using the wiring method shown in Figure 1.&lt;BR&gt;2. Wiring of single-phase expansion method&lt;BR&gt;If the controlled electrical appliance is supplied with single-phase power and the power consumption exceeds the rated capacity of this switch (resistive load exceeding 25A, inductive load exceeding 20A), then an AC contactor with a capacity exceeding the power consumption of the appliance is required to expand the capacity. The wiring method is shown in Figure 2.&lt;BR&gt;3. Wiring of three-phase working mode&lt;BR&gt;The controlled electrical appliance is powered by three-phase power and requires an external three-phase AC contactor&lt;BR&gt;a¡¢ As shown in Figure 3, the coil voltage of the control contactor is AC220V 50/60Hz.&lt;BR&gt;b¡¢ As shown in Figure 4, the coil voltage of the control contactor is AC380V 50/60Hz.&lt;BR&gt;&lt;BR&gt;Outline and installation dimension diagram of KG316T microcomputer time control switch&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200708/20078383559323.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 365px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of KG316T microcomputer time control switch&quot; src=&quot;/uploadfiles/200708/20078383559323.gif&quot; width=400 height=365&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200708/20078383622579.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 381px; WIDTH: 320px; FILTER: none&quot; border=0 hspace=0 alt=&quot;KG316T microcomputer time control switch wiring diagram&quot; src=&quot;/uploadfiles/200708/20078383622579.gif&quot; width=320 height=381&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;KG316T microcomputer time control switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>