           <title>[Ceramic arc extinguishing chamber]ZMF-12/630-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26465.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:23</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/630-20 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;ZMF-12/630-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated peak closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;≒35米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;150&#177;30N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202601413.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/630-20 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202601413.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26464.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:15</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/630-12.5 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;ZMF-12/630-12.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated peak closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;100&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;160&#177;30N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202334329.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/630-12.5 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202334329.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/400-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26463.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:07</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/400-20 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;ZMF-12/400-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;2KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Vacuum self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Maximum opening distance of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;4mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Tensile force at a contact opening distance of 4mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;120&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact resistance when the contact naturally closes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;≒200米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Power frequency withstand voltage at a contact distance of 4mm (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Maximum closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202011723.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/400-20 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202011723.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/400-16 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26462.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:58</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/400-16 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;ZMF-12/400-16&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;50HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Vacuum self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Maximum opening distance of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;6mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Tensile force at a contact opening distance of 4mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10&#177;15N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact resistance when the contact naturally closes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;≒70米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Power frequency withstand voltage at a contact distance of 4mm (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;38-42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Maximum closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;16KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112201550259.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/400-16 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112201550259.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-12/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24922.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:49</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD32-12/630-12.5 vacuum circuit breaker is made of ceramic shell and is used for mining switches.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-7.2/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24921.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:38</pubDate>
           <comments></comments>
           <description>TD32-7.2/630-12.5 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD25-12/1250-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24920.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:28</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for TD25-12/1250-20 vacuum circuit breaker&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD25-12/630 series Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24919.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:20</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD25-12/630 series vacuum circuit breakers is made of ceramic shell and is used for ZW33-12/D630-20 (recloser) and other applications.&lt;BR&gt;&lt;BR&gt;TD25-12/630-20&lt;BR&gt;TD25-12/630-20C&lt;BR&gt;TD25-12/630-20A&lt;BR&gt;TD25-12/630-16&lt;BR&gt;TD25-12/630-20&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1000-25 (TD4803A) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24918.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:11</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/1000-25 (TD4803A) vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-31.5R (TD34-12/1250-31.5B) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24917.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:03</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/1250-31.5R (TD34-12/1250-31.5B) vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 vacuum circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24916.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:55</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/3150-40 vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 with long service life KYN96-12ㄗAMS1ㄘ﹝&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24915.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:46</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/3150-40A vacuum circuit breaker is a ceramic insulated shell used for ZN63-12 solid sealed vacuum circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/2000-31.5F ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24914.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:38</pubDate>
           <comments></comments>
           <description>TD14A-12/2000-31.5F ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/2500-31.5F Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24913.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:29</pubDate>
           <comments></comments>
           <description>The vacuum interrupter for TD14A-12/2500-31.5F vacuum circuit breaker is a ceramic vacuum interrupter used in vacuum circuit breakers such as ZN63, ZN65, ZN68-12, etc.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/630 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24912.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:21</pubDate>
           <comments></comments>
           <description>The TD14A-12/630 vacuum circuit breaker is equipped with ceramic vacuum arc extinguishing chambers for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, and ZN68 circuit breakers.&lt;BR&gt;&lt;BR&gt;TD14A-12/630-20&lt;BR&gt;TD14A-12/630-25&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1000 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24911.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:12</pubDate>
           <comments></comments>
           <description>The ceramic vacuum arc extinguishing chamber for TD14A-12/1000 vacuum circuit breaker is used for circuit breakers ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, and ZN68.&lt;BR&gt;&lt;BR&gt;TD14A-12/1000-20&lt;BR&gt;TD14A-12/1000-25&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-20 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24910.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:04</pubDate>
           <comments></comments>
           <description>TD14A-12/1250-20 ceramic vacuum interrupter is used for high-voltage vacuum circuit breakers such as ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68, etc.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-31.5J Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24909.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:55</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;TD14A-12/1250-31.5J ceramic vacuum arc extinguishing chamber for vacuum circuit breakers, suitable for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68.&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-31.5L Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24908.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:47</pubDate>
           <comments></comments>
           <description>TD14A-12/1600-31.5L ceramic vacuum arc extinguishing chamber is used for ZN168 (VBG) -12, ZN63, ZN65 and other circuit breakers, with a long life of 100000 cycles.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-25 ceramic insulated shell vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24907.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:38</pubDate>
           <comments></comments>
           <description>TD14A-12/1600-25 ceramic insulated shell vacuum arc extinguishing chamber&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-25 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24906.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:30</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14A-12/1250-25 vacuum circuit breaker is a ceramic insulated shell, used for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68 vacuum circuit breakers&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-31.5B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24905.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:22</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14A-12/1600-31.5B vacuum circuit breaker is a ceramic insulated shell, used for ZN28﹜ZN22﹜ZN33﹜ZN58﹜ZN63﹜ZN65﹜ZN68﹝&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1250-31.5B/Z Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24904.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:13</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14-12/1250-31.5B/Z vacuum circuit breaker is a ceramic insulated shell arc extinguishing chamber, used for ZN28, ZN22, ZN33, ZN63, ZN68, altitude ≒ 4300m.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1600-31.5B/Z (TD14-12/1600-31.5D)Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24903.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:05</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14-12/1600-31.5B/Z (TD14-12/1600-31.5D) vacuum circuit breaker is a ceramic insulated shell. Used for ZN28, ZN22, ZN33, ZN63, ZN68, altitude ≒ 4300m.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1250-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24902.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:56</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber (TD303A) for TD14-12/1250-25A vacuum circuit breaker is a ceramic insulated housing used for ZN63&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD諳7-12/6300-80A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24901.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:48</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD諳7-12/6300-80A vacuum circuit breaker is a ceramic insulated shell vacuum arc extinguishing chamber used for generator protection of the circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD0132A Low voltage vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24896.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:39</pubDate>
           <comments></comments>
           <description>TD0132A Low pressure vacuum arc extinguishing chamber&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD12/630-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20718.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:31</pubDate>
           <comments></comments>
           <description>ZMD12/630-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;ZMD12/630-20&lt;BR&gt;ZMD12/630-20(I)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time (lmin) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;150&#177;50N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact reaction force under contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Allowable thickness for electrical wear of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;3.5kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112195552367.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 200px; HEIGHT: 387px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZMD12/630-20 ceramic vacuum arc extinguishing chamber&quot; src=&quot;/upload2015/201501/20150112195552367.jpg&quot; width=200 height=387&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD12/800-25 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20717.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:23</pubDate>
           <comments></comments>
           <description>ZMD12/800-25 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;ZMD12/800-25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;800A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;25KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;63KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;63KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;25KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time (lmin) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒40米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;150&#177;50N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact reaction force under contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Allowable thickness for electrical wear of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3.3kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112195746983.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 250px; HEIGHT: 314px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZMD12/800-25 ceramic vacuum arc extinguishing chamber&quot; src=&quot;/upload2015/201501/20150112195746983.jpg&quot; width=250 height=314&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD14-1250, 1600/10-31.5 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20716.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:14</pubDate>
           <comments></comments>
           <description>ZMD14-1250, 1600/10-31.5 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;ZMD14-1250/10-31.5&lt;BR&gt;ZMD14-1600/10-31.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;50~60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1250﹜1600A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;80KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;80KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;30/50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;160&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1.18kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4.1kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Mechanical parameters that the matching vacuum circuit breaker should meet&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;11&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1.1&#177;0.2m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;0.6&#177;0.2m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;3350&#177;320N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒2ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒1ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD14-1250, 1600/10-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20715.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:06</pubDate>
           <comments></comments>
           <description>ZMD14-1250, 1600/10-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;ZMD14-1250/10-20&lt;BR&gt;ZMD14-1600/10-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50~60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1250﹜1600A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;30/50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;160&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1.05kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4.kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Mechanical parameters that the matching vacuum circuit breaker should meet&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;11&#177;1.5/0 mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1&#177;0.3m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;0.55&#177;0.15m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;2000&#177;200N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒2ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒1ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160/1.14 ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/20711.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:57</pubDate>
           <comments></comments>
           <description>ZKTJ-160/1.14 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 470px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=470 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;ZKTJ-160/1.14&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Contact resistance (米 次)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;≒200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Vacuum self closing force (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;17.6&#177;4.9&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;zero point two three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=134&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;98&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;孜35.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZKTJ-160/1.14 ceramic vacuum switch tube&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-80/0.66 ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/20710.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:49</pubDate>
           <comments></comments>
           <description>ZKTJ-80/0.66 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;Rated voltage 660V, rated current 80A, ultimate breaking capacity 1600A, contact resistance ≒ 300, mass 0.11kg.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 470px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=470 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;ZKTJ-80/0.66&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;six hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Contact resistance (米 次)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;≒300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Vacuum self closing force (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;17&#177;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;zero point one one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=134&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;68.5&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;孜30&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZKTJ-80/0.66 ceramic vacuum switch tube&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD21-40.5/2000-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20066.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:40</pubDate>
           <comments></comments>
           <description>TD21-40.5/2000-31.5 Ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD12-40.5/2500-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20065.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:32</pubDate>
           <comments></comments>
           <description>TD12-40.5/2500-31.5 Ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-40.5/1600-31.5 Ceramic Vacuum Arc Extinguisher Chamber </title>
           <link>http://www.91way.com/info_en/20064.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:23</pubDate>
           <comments></comments>
           <description>TD27-40.5/1600-31.5 Ceramic Vacuum Arc Extinguisher Chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-40.5/2000-31.5 Ceramic Vacuum Arc Extinguisher Chamber </title>
           <link>http://www.91way.com/info_en/20063.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:15</pubDate>
           <comments></comments>
           <description>TD27-40.5/2000-31.5 Ceramic Vacuum Arc Extinguisher Chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-40.5/1250-16 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20062.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:05</pubDate>
           <comments></comments>
           <description>TD24-40.5/1250-16 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-40.5/630-12.5 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20061.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:56</pubDate>
           <comments></comments>
           <description>TD24-40.5/630-12.5 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/3150-31.5C ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20060.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:48</pubDate>
           <comments></comments>
           <description>TD34-24/3150-31.5C ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/1600-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20059.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:40</pubDate>
           <comments></comments>
           <description>TD34-24/1600-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/630-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20058.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:31</pubDate>
           <comments></comments>
           <description>TD34-24/630-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-36/2000-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20057.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:23</pubDate>
           <comments></comments>
           <description>TD27-36/2000-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD17-38/1250-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20056.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:13</pubDate>
           <comments></comments>
           <description>TD17-38/1250-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD17-38/630-16 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20055.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:05</pubDate>
           <comments></comments>
           <description>TD17-38/630-16 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-36/2000-25A ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20054.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:57</pubDate>
           <comments></comments>
           <description>TD27-36/2000-25A ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/1250-20A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20053.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:48</pubDate>
           <comments></comments>
           <description>TD34-24/1250-20A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/6300-80A ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20052.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:40</pubDate>
           <comments></comments>
           <description>TD-12/6300-80A ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-12/630-20C ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20051.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:28</pubDate>
           <comments></comments>
           <description>TD24-12/630-20C ceramic vacuum arc extinguishing chamber (TD3738AF1)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20049.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:19</pubDate>
           <comments></comments>
           <description>TD34-12/1250-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1600-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20048.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:11</pubDate>
           <comments></comments>
           <description>TD34-12/1600-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20047.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:03</pubDate>
           <comments></comments>
           <description>TD34-12/1250-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/630-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20046.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:53</pubDate>
           <comments></comments>
           <description>TD34-12/630-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40C/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20045.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:44</pubDate>
           <comments></comments>
           <description>TD34-12/3150-40C/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/4000-40C/R Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20044.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:36</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD34-12/4000-40C/R vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD31-12/630-20B/R Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20000.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:28</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD31-12/630-20B/R vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD31-12/630-20B Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19999.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:19</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD31-12/630-20B vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-12/800-13.1 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19998.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:11</pubDate>
           <comments></comments>
           <description>TD32-12/800-13.1 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/5000-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14490.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623220429395.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 336px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/5000-12.5 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623220429395.jpg&quot; width=612 height=336&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-1.14/5000-12.5 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/450-10 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14489.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623220221210.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/450-10 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623220221210.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-1.14/450-10 vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/400-8 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14488.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623215830515.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 645px; HEIGHT: 345px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/400-8 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623215830515.jpg&quot; width=645 height=345&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-1.14/400-8 vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-7.2/400 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14487.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214505767.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 471px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for ZKTJ-7.2/400 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214505767.jpg&quot; width=600 height=471&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for ZKTJ-7.2/400 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-7.2/250 vacuum interrupter for vacuum contactor </title>
           <link>http://www.91way.com/info_en/14486.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:28</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214319632.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for ZKTJ-7.2/250 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214319632.jpg&quot; width=600 height=416&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKTJ-7.2/250 vacuum interrupter for vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-12/160 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14485.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:20</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214047363.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-12/160 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214047363.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-12/160 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-7.2/630 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14484.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623213939762.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 681px; HEIGHT: 329px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-7.2/630 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213939762.jpg&quot; width=681 height=329&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-7.2/630 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-7.2/160 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14483.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:03</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623213743801.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-7.2/160 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213743801.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-7.2/160 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/1000 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14482.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213602929.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 616px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/1000 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213602929.jpg&quot; width=616 height=270&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/1000 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/630 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14481.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:46</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213430723.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 618px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/630 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213430723.jpg&quot; width=618 height=291&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/630 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/400 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14480.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213250281.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 484px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-1.14/400 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213250281.jpg&quot; width=484 height=310&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/400 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/300 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14479.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213103587.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 589px; HEIGHT: 311px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-1.14/300 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213103587.jpg&quot; width=589 height=311&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/300 vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14-250 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14478.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623212914995.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 538px; HEIGHT: 314px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14-250 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623212914995.jpg&quot; width=538 height=314&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14-250 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/200 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14476.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:12</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204746377.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 497px; HEIGHT: 326px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/200 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204746377.jpg&quot; width=497 height=326&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/200 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/125(B) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14475.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:04</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204543307.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 516px; HEIGHT: 316px&quot; border=0 hspace=0 alt=&quot;TJ-1.14/125 (B) Dimensions of vacuum arc extinguishing chamber for vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204543307.jpg&quot; width=516 height=316&gt;&lt;/A&gt;&lt;BR&gt;TJ-1.14/125 (B) Vacuum arc extinguishing chamber for vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/125 (A) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14474.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:55</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204329385.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;TJ-1.14/125 (A) Dimensions of vacuum arc extinguishing chamber for vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204329385.jpg&quot; width=380 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TJ-1.14/125 (A) Vacuum arc extinguishing chamber for vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/3150-40(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14233.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:47</pubDate>
           <comments></comments>
           <description>&lt;SPAN&gt;TD-12/3150-40 (310mm) Solid Sealing Pole Arc Extinguishing Chamber Solid Sealing Pole 3150-40 Dimensions and Technical Parameters Table&lt;/SPAN&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-180s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;4200&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232727332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;TD-12/3150-40 (310mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232727332.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/3150-40 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-31.5(275mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14232.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:38</pubDate>
           <comments></comments>
           <description>Technical parameter table for TD-12/2000-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒12&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232508389.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 380px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-31.5 (275mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232508389.jpg&quot; width=680 height=380&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5(275mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14231.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:30</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-12/1250-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;1.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3+10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232259273.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 (275mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232259273.jpg&quot; width=680 height=250&gt;&lt;/A&gt;&lt;BR&gt;TD-12/1250-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/3150-40 Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14230.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:21</pubDate>
           <comments></comments>
           <description>&lt;SPAN&gt;TD-24/3150-40 Solid Sealed Pole Arc Extinguishing Chamber Dimensions and Technical Parameters Table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-180s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;4200&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/SPAN&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617231654330.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/3150-40 solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617231654330.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/3150-40 solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2500-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14229.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:12</pubDate>
           <comments></comments>
           <description>Table of Dimensions and Technical Parameters for Solid Sealed Pole 24kV/2500-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/SPAN&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617231437984.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 460px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/2500-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617231437984.jpg&quot; width=680 height=460&gt;&lt;/A&gt;&lt;BR&gt;TD-24/2500-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2000-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14228.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:04</pubDate>
           <comments></comments>
           <description>Table of Dimensions and Technical Parameters for Sealed Pole 2000-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617223902247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 380px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/2000-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617223902247.jpg&quot; width=680 height=380&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/2000-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1600-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14227.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:55</pubDate>
           <comments></comments>
           <description>TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;Table of Dimensions and Technical Parameters for Solid Sealed Pole 24kV/1600-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒16&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617223701704.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617223701704.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5(205mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14226.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:46</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;1.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100617223246247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 (205mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617223246247.jpg&quot; width=660 height=295&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14225.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:37</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;110&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;190&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;13&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617222548391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100617222548391.jpg&quot; width=680 height=270&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14224.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:29</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;110&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;190&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;13&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617222241248.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100617222241248.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2000, TD-24/2500-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14223.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:20</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chambers for TD-24/2000, TD-24/2500-31.5 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;2000/2500&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;sixty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3+&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100617221957987.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chambers for circuit breakers TD-24/2000, TD-24/2500-31.5&quot; src=&quot;/upload2010/201006/20100617221957987.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for circuit breakers TD-24/2000, TD-24/2500-31.5&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/2000,TD-40.5/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14222.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:12</pubDate>
           <comments></comments>
           <description>Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1600/2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated Active load breaking current &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;20&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.75&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot; align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617221448550.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 636px; HEIGHT: 277px&quot; border=0 hspace=0 alt=&quot;TD-40.5/2000, TD-40.5/1600-31.5 Vacuum arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617221448550.jpg&quot; width=636 height=277&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-40.5/2000-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-12/630-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14221.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:03</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TF-12/630-20 load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated Active load breaking current &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Transfer current (AC current)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three point one five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated closed-loop breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated cable charging breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated no-load transformer breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;80&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;140&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot; align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617220255520.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 636px; HEIGHT: 284px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TF-12/630-20 load switch&quot; src=&quot;/upload2010/201006/20100617220255520.jpg&quot; width=636 height=284&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TF-12/630-20 load switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630-6 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14220.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:55</pubDate>
           <comments></comments>
           <description>Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current (maximum/minimum)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;5.0/0.12&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Maximum breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated turn-on current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Withstand overload current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=441&gt;
&lt;P align=center&gt;electrical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;25 (AC-3 category)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1 (AC-4 category)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;85&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;130&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance under self isolation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.45&#177;0.05&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.25&#177;0.05&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Three phase synchronicity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point five&lt;SUP&gt;+0.5&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215909354.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 486px; HEIGHT: 242px&quot; border=0 hspace=0 alt=&quot;TJC-7.2/630-6 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617215909354.jpg&quot; width=486 height=242&gt;&lt;/A&gt;&lt;BR&gt;TJC-7.2/630-6 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-7.2/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14219.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:46</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-7.2/630-12.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve point five eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;80&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for TD-7.2/630-12.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;8&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Contact stroke of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;2+10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215631304.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 565px; HEIGHT: 317px&quot; border=0 hspace=0 alt=&quot;TD-7.2/630-12.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617215631304.jpg&quot; width=565 height=317&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-7.2/400-10 Vacuum arc extinguishing chamber for circuit breakers (mining) </title>
           <link>http://www.91way.com/info_en/14218.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:38</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-7.2-400-10 circuit breaker (mining)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;85&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;8&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;650&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two&lt;SUP&gt;+0.5&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215329935.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 305px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-7.2-400-10 circuit breaker (mining)&quot; src=&quot;/upload2010/201006/20100617215329935.jpg&quot; width=600 height=305&gt;&lt;/A&gt;&lt;BR&gt;TD-7.2-400-10 vacuum arc extinguishing chamber for circuit breakers (mining)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/4000-40  Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14217.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:29</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4000&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switchgear equipment for vacuum arc extinguishing chambers (ZN63, ZN28) used in TD-12/4000-40 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3+1 0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617214908600.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 319px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&quot; src=&quot;/upload2010/201006/20100617214908600.jpg&quot; width=540 height=319&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZN63,ZN28) Vacuum arc extinguishing chamber for circuit breakers </title>
           <link>http://www.91way.com/info_en/14216.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:21</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;2500/3150&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switchgear equipment for vacuum arc extinguishing chambers (ZN63, ZN28) used in TD-12/3150-40 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617214602630.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 319px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&quot; src=&quot;/upload2010/201006/20100617214602630.jpg&quot; width=540 height=319&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14215.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:12</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1250/1600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;10&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4300&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617213732180.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40&quot; src=&quot;/upload2010/201006/20100617213732180.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for circuit breakers TD-12/1250-40, TD-12/1600-40&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-12/630 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14042.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:04</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The arc extinguishing chamber adopts corrugated ceramic as the insulation shell, and the contacts are made of copper tungsten carbide alloy material. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated short-time withstand current voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;BR&gt;Rated lighting impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;70&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;BR&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Synchronization of closing&lt;BR&gt;Closing same period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614234036163.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic vacuum arc extinguishing chamber for TJC-12/630 contactor&quot; src=&quot;/upload2010/201006/20100614234036163.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-12/630 contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-12.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14038.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:55</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, low noise, etc. The outdoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Explanation of Ceramic Vacuum Arc Extinguishing Chamber for TD-12/630-12.5 Circuit Breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;60&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Force required to hold contacts open at full stroke at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;160&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Contact limit abrasion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;zero point three five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;8&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;1200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Contact bounce duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614232005703.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 418px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100614232005703.jpg&quot; width=418 height=580&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1600-25 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14037.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:47</pubDate>
           <comments></comments>
           <description>The ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. Indoor vacuum circuit breakers assembled with it are used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Parameter Name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;rated voltage&lt;/P&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;rated current&lt;/P&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;mechanical life&lt;/P&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;
&lt;P&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;300&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allowable storage period&lt;/P&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;P align=left&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;contact gap&lt;/P&gt;
&lt;P&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;22&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;8&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;2800&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;/P&gt;
&lt;P&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614231649277.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 413px; HEIGHT: 515px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1600-25 Ceramic vacuum arc extinguishing chamber for circuit breakers - Dimensions&quot; src=&quot;/upload2010/201006/20100614231649277.jpg&quot; width=413 height=515&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-25 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14036.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:38</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The arc extinguishing chamber adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current times&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;140&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;230&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact limit erosion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Quality of the sports section&lt;BR&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;one point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;2000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614231218983.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 378px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Dimensions of ceramic vacuum arc extinguishing chamber for TD-12/630-25 circuit breaker&quot; src=&quot;/upload2010/201006/20100614231218983.jpg&quot; width=378 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/630-25 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630B Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14035.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:30</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The TJC-7.2/630B contactor uses a ceramic vacuum arc extinguishing chamber with a corrugated ceramic insulation shell and copper tungsten carbide alloy contacts. It adopts advanced one-time sealing technology and has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;BR&gt;Rated lighting impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;70&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact -wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;BR&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614224227482.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&quot; src=&quot;/upload2010/201006/20100614224227482.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630A Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14034.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:21</pubDate>
           <comments></comments>
           <description>The TJC-7.2/630A contactor uses a ceramic vacuum arc extinguishing chamber with a corrugated ceramic insulation shell and copper tungsten carbide alloy contacts. It adopts advanced one-time sealing technology and has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;70&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;&lt;/P&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=left&gt;unit&lt;/P&gt;
&lt;P align=left&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;numerical value&lt;/P&gt;
&lt;P align=left&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614223511336.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&quot; src=&quot;/upload2010/201006/20100614223511336.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/600 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14033.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:13</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/600 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-1.14/600 low-voltage contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;four thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;four thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;shelf life&lt;BR&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614223109776.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/600 Ceramic Vacuum Arc Extinguisher Chamber Outline Dimensional Drawing for Low Voltage Contactors&quot; src=&quot;/upload2010/201006/20100614223109776.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;TJC-1.14/600 Ceramic Vacuum Arc Extinguishing Chamber for Low Voltage Contactors&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14-400 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14032.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:04</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14-400 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;TJC-1.14-400 Mechanical parameters of ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.3&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614222658503.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14-400 Ceramic Vacuum Arc Extinguisher for Low Voltage Contactors - Dimensions&quot; src=&quot;/upload2010/201006/20100614222658503.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-1.14-400 low-voltage contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/250A Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14031.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:56</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/250A low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-1.14/250A low-voltage contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;50&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;70&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.6&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614222233345.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/250A Ceramic Vacuum Arc Extinguisher for Low Voltage Contactors - External Dimensions&quot; src=&quot;/upload2010/201006/20100614222233345.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-1.14/250A low-voltage contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/125 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14030.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:47</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/125 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=187&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=187&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;20&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;50&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;≒120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;shelf life&lt;BR&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;TJC-1.14/125 Mechanical parameters of ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;1.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;0.6&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;35&#177;5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614221941214.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 494px; HEIGHT: 299px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/125 Ceramic vacuum arc extinguishing chamber for low-voltage contactors - Dimensions&quot; src=&quot;/upload2010/201006/20100614221941214.jpg&quot; width=494 height=299&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TJC-1.14/125 Ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-40.5/1250-20 Ceramic arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14029.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:39</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch adopts a ceramic insulation shell, low current cutoff value, and long-life Wcu contact material, which has the advantages of strong arc extinguishing ability, reliable performance, long life, small size, no explosion hazard, and no environmental pollution The corresponding vacuum automatic switch can be used for control and protection of transmission and distribution systems in power, metallurgy, mining, chemical and other departments, especially suitable for places that require frequent operation. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Parameter Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;50/60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;BR&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;BR&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit closing current&lt;BR&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;BR&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;145&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact limit abrasion thickness allowed for contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;zero point four five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;15&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;1.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;700&#177;100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614221509831.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&quot; src=&quot;/upload2010/201006/20100614221509831.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-12/630-12.5 Ceramic arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14028.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:30</pubDate>
           <comments></comments>
           <description>The ceramic arc extinguishing chamber for TF-12/630-12.5 load switch adopts a ceramic insulation shell, low current cutoff value, long-life Wcu contact material, which has the advantages of strong arc extinguishing ability, reliable performance, long life, small size, no explosion hazard, and no environmental pollution The corresponding vacuum automatic switch can be used for control and protection of transmission and distribution systems in power, metallurgy, mining, chemical and other departments, especially suitable for places that require frequent operation.&lt;BR&gt;&lt;BR&gt;Product Description&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;BR&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;BR&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit closing current&lt;BR&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;BR&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current times&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;65&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;175&#177;35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact limit erosion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Quality of the sports section&lt;BR&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;zero point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupte&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;one point seven five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;contact gap&lt;BR&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;9&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Average opening speed&lt;BR&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.8&#177;0.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Average closing speed&lt;BR&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Rated contact pressure&lt;BR&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;700&#177;100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614213612135.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic arc extinguishing chamber for TF-12/630-12.5 load switch&quot; src=&quot;/upload2010/201006/20100614213612135.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ceramic arc extinguishing chamber for TF-12/630-12.5 load switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-20 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14023.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:22</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Parameter Name&lt;BR&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;time&lt;/P&gt;
&lt;P align=left&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Next Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;2000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614210557901.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 412px; HEIGHT: 505px&quot; border=0 hspace=0 alt=&quot;Dimensions of ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker&quot; src=&quot;/upload2010/201006/20100614210557901.jpg&quot; width=412 height=505&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1600-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14022.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:13</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Next Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 468px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=468 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;3&#177;&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614210052120.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 420px; HEIGHT: 520px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100614210052120.jpg&quot; width=420 height=520&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2500-40 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14021.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;Main technique parameter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;
&lt;P align=center&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;
&lt;P align=center&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P align=center&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P align=center&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P align=center&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P align=center&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P align=center&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P align=center&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;
&lt;P align=center&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;
&lt;P align=center&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P align=center&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P align=center&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;
&lt;P align=center&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P align=center&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;3&#177;&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;4000&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P align=center&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;
&lt;P align=center&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614205013448.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 421px; HEIGHT: 516px&quot; border=0 hspace=0 alt=&quot;Dimensions of Ceramic Vacuum Extinguishing Chamber for TD-12/2500-40 Circuit Breaker&quot; src=&quot;/upload2010/201006/20100614205013448.jpg&quot; width=421 height=516&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9230.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:56</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-40.5/1600-31.5 vacuum arc extinguishing chamber adopts copper chromium contact material, cup-shaped longitudinal magnetic field structure, stainless steel corrugated tube, ceramic shell and exposed shielding tube. The product has the characteristics of large breaking capacity, good insulation performance, and long mechanical life. Paired with corresponding vacuum circuit breakers, it can be widely used in power systems as a control and protection device for circuits, especially suitable for places with frequent operation.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV0&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and eighty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;170&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;320&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;twelve point eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-40.5/1600-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;25&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;2.0&#177;0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.8&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/2009111384340533.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 430px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1600-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/2009111384340533.jpg&quot; width=680 height=430&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9229.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:47</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-40.5/1250-31.5 vacuum arc extinguishing chamber adopts copper chromium contact material, cup-shaped longitudinal magnetic field structure, stainless steel corrugated tube, ceramic shell and exposed shielding tube. The product has the characteristics of large breaking capacity, good insulation performance, and long mechanical life. Paired with corresponding vacuum circuit breakers, it can be widely used in power systems as a control and protection device for circuits, especially suitable for places with frequent operation.&lt;BR&gt;&lt;BR&gt;Main technical parameters of TD-40.5/1250-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV0&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and eighty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;170&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;320&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;twelve point eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;25&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;2.0&#177;0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.8&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/200911138400871.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 420px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1250-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138400871.jpg&quot; width=680 height=420&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9228.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:38</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;TD-12/2000-40 vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Paired with corresponding vacuum circuit breakers, it is particularly suitable for power distribution systems and frequently operated places in departments such as electricity, machinery, chemical engineering, metallurgy, and mining.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-180S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;210&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;300&#177;70&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;two point two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;six point six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;5000&#177;300&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138139854.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 360px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-40 vacuum arc extinguishing chamber external dimensions&quot; src=&quot;/upload2009/200911/200911138139854.jpg&quot; width=680 height=360&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9227.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:30</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Matched with corresponding vacuum circuit breakers or vacuum distribution devices, it is particularly suitable for places where circuits are frequently operated in all working conditions of departments such as power, machinery, chemical, metallurgical, mining, etc.&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=236 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=197 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3 (0.5) S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;210&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;300&#177;70&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;two point two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;six point six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138949108.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138949108.jpg&quot; width=680 0=&quot;None&quot;&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9226.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:21</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;The TD-12/1250-31.5 vacuum arc extinguishing chamber adopts a corrugated ceramic shell, with copper chromium contacts and a cup-shaped longitudinal magnetic field structure. It has the advantages of large interruption capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments. Especially suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;230&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point two six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point six five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/1250-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.85&#177;0.85&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138612326.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138612326.jpg&quot; width=680 height=330&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-25, TD-12/1250-25N vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9225.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:13</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers are equipped with corrugated ceramic shells, copper chromium contacts, and cup-shaped longitudinal magnetic field structures. It has the advantages of large interruption capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments. Especially suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;240&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2500&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091113826405.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers&quot; src=&quot;/upload2009/200911/20091113826405.jpg&quot; width=680 height=330&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-20B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9224.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:04</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;&lt;BR&gt;TD-12/630-20B vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Paired with corresponding indoor and outdoor vacuum circuit breakers, it is suitable for accompanying power systems in industrial sectors such as power, machinery, chemical, metallurgical, and mining, especially in places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=49 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=281 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;240&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/630-20B vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=98 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=232 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2000&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112233517858.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-12/630-20B vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/20091112233517858.jpg&quot; width=680 0=&quot;None&quot;&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZW8 Vacuum arc extinguishing chamber (ZW8 dedicated) </title>
           <link>http://www.91way.com/info_en/9223.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview:&lt;BR&gt;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and glass or ceramic as insulation shell. The product has the characteristics of small size, large breaking capacity, and high pressure resistance. Paired with corresponding outdoor vacuum circuit breakers or vacuum distribution devices, it can be widely used in places where circuits are frequently operated in industrial sectors such as power, machinery, chemical, metallurgical, mining, etc.&lt;BR&gt;&lt;BR&gt;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=32 width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD height=32 align=middle&gt;unit&lt;/TD&gt;
&lt;TD height=32 width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;95&#177;35&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;215&#177;40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=32 width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD height=32 align=middle&gt;unit&lt;/TD&gt;
&lt;TD height=32 width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;8&#177;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2000&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112232337726.jpg&quot; target=_blank&gt;&lt;/A&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112232429802.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 420px&quot; border=0 hspace=0 alt=&quot;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) external dimensions&quot; src=&quot;/upload2009/200911/20091112232429802.jpg&quot; width=680 height=420&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-31.5B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/6820.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Introduction to TD14A-12/1250-31.5B vacuum arc extinguishing chamber:&lt;BR&gt;Overall Dimension Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200910/2009101885922198.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 449px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD14A-12/1250-31.5B vacuum arc extinguishing chamber&quot; src=&quot;/uploadfiles/200910/2009101885922198.jpg&quot; width=449 height=580&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center cellpading=&quot;10&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TH scope=col&gt;parameter name&lt;/TH&gt;
&lt;TH scope=col&gt;parameter value&lt;/TH&gt;
&lt;TH scope=col&gt;unit&lt;/TH&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD&gt;forty-two&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;thirty-one point five&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;thirty-one point five&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;O-0.3(0.5)s-CO-180s-CO&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current times&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;twenty thousand&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact self closing force&lt;/TD&gt;
&lt;TD&gt;140&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force at rated opening distance&lt;/TD&gt;
&lt;TD&gt;230&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;米次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Allowable wear thickness of contacts&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;zero point zero zero one&lt;/TD&gt;
&lt;TD&gt;Pa&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD&gt;one point four&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;four point seven&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;contact gap&lt;/TD&gt;
&lt;TD&gt;11&#177;1&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average opening speed&lt;/TD&gt;
&lt;TD&gt;1.1&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average closing speed&lt;/TD&gt;
&lt;TD&gt;0.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD&gt;3100&#177;200&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;outer diameter&lt;/TD&gt;
&lt;TD&gt;one hundred and six&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;installation height&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;appearance&lt;/TD&gt;
&lt;TD&gt;Umbrella skirt, climbing distance ≡ 240&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD21-40.5/1600-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/6818.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;TD21-40.5/1600-20 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;Overall Dimension Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200910/2009101885418615.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 433px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;TD21-40.5/1600-20 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/uploadfiles/200910/2009101885418615.jpg&quot; width=433 height=580&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TH&gt;parameter name&lt;/TH&gt;
&lt;TH&gt;parameter value&lt;/TH&gt;
&lt;TH&gt;unit&lt;/TH&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD&gt;ninety-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;one hundred and eighty-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;O-0.3s-CO-180s-CO&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current times&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;ten thousand&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact self closing force&lt;/TD&gt;
&lt;TD&gt;180&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force at rated opening distance&lt;/TD&gt;
&lt;TD&gt;300&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;米次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Allowable wear thickness of contacts&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;zero point zero zero one&lt;/TD&gt;
&lt;TD&gt;Pa&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD&gt;three point six seven&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;contact gap&lt;/TD&gt;
&lt;TD&gt;22&#177;2&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average opening speed&lt;/TD&gt;
&lt;TD&gt;1.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average closing speed&lt;/TD&gt;
&lt;TD&gt;0.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD&gt;2500&#177;200&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;outer diameter&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-eight&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;installation height&lt;/TD&gt;
&lt;TD&gt;four hundred and fourteen&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;appearance&lt;/TD&gt;
&lt;TD&gt;Shielding tube exposed&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;TD21-40.5/1600-20 vacuum arc extinguishing chamber&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKBF-12/630-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2248.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKBF type vacuum switch tube uses high alumina glass as the insulating shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgical, textile, and high-rise buildings.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC high-voltage vacuum load switch, serving as protection and control for electrical facilities. Used for dividing and combining load current, closed-loop current, no-load transformer, and cable charging current.&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated voltage 12KV&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated peak withstand current 50KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated active load breaking current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated short-circuit closing current 50KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated closed-loop breaking current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with load switch FZN21-12D/T630-20 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated cable charging breaking current 10A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Contact self closing force 190 &#177; 20N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated breaking no-load transformer capacity 1250KVA&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 24N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742120045462.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 248px&quot; border=0 hspace=0 alt=&quot;ZKBF-12/630-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742120045462.jpg&quot; width=509 height=248&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTDW-630/12-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2243.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:22</pubDate>
           <comments></comments>
           <description>The ZKTD vacuum switch tube adopts high alumina ceramic as the insulation shell, and is covered with high-strength corrugated insulation material on the outside. The tube uses high vacuum as the medium, so it is resistant to high voltage, has strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, textile, and high-rise buildings.&lt;BR&gt;This product, equipped with a suitable operating mechanism, can be assembled into an AC circuit breaker, used as a distribution device in three-phase AC power generation and supply systems, and as a centralized control device for electric motors.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated working voltage 10KV&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated working current 630A&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-circuit breaking current 20KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Impulse withstand voltage 75KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-circuit breaking frequency 30 times&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Contact self closing force 100 &#177; 10N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated closing current (peak) 50KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Contact reaction force at rated opening distance of 140 &#177; 14N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated current breaking times 1000 times&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated contact pressure and contact resistance ≒ 100 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Mechanical lifespan of 100 million cycles&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Equipped with circuit breaker ZW8-12 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-time withstand current 20KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421164342279.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 328px&quot; border=0 hspace=0 alt=&quot;ZKTDW-630/12-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164342279.jpg&quot; width=275 height=328&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-630/10KV-I,II type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2242.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZKTD ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell, and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC circuit breaker for use in power distribution control devices, for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;Rated working voltage 10KV&lt;BR&gt;Rated working current 400, 630A&lt;BR&gt;Rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times&lt;BR&gt;Rated current breaking frequency 3000 times&lt;BR&gt;Mechanical lifespan of 15000 cycles&lt;BR&gt;Rated short-time withstand current 12.5KA&lt;BR&gt;Rated short-time withstand time 4S&lt;BR&gt;Rated power frequency withstand voltage 42KV&lt;BR&gt;Rated opening torque 8 &#177; 1mm&lt;BR&gt;Contact self closing force 115 &#177; 11N&lt;BR&gt;Contact reaction force at rated opening moment 140 &#177; 14N&lt;BR&gt;Contact resistance under rated contact pressure ≒ 100 米 次&lt;BR&gt;Type I is equipped with Jiyuan Circuit Breaker Type A&lt;BR&gt;Type II equipped with Jiyuan Circuit Breaker Type A&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742116427947.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;ZKTD-630/10KV-I, II type ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742116427947.jpg&quot; width=509 height=260&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKTD-630/10KV-I, II type ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-400(630)/6KV type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2241.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:04</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKTD ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell, and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC circuit breaker for use in power distribution control devices, for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;Rated working voltage 6KV&lt;BR&gt;Rated working current 400, 630A&lt;BR&gt;Rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times&lt;BR&gt;Rated current breaking frequency 3000 times&lt;BR&gt;Mechanical lifespan of 15000 cycles&lt;BR&gt;Rated short-time withstand current 12.5KA&lt;BR&gt;Rated short-time withstand time 4S&lt;BR&gt;Rated power frequency withstand voltage 32KV&lt;BR&gt;Rated opening torque 4 &#177; 0.4mm, contact self closing force 115 &#177; 11N&lt;BR&gt;Contact reaction force at rated opening moment 140 &#177; 14N&lt;BR&gt;Contact resistance under rated contact pressure ≒ 100 米 次&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421164027341.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 236px&quot; border=0 hspace=0 alt=&quot;ZKTD-400 (630)/6KV ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164027341.jpg&quot; width=509 height=236&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-630/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2240.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZKTD-630/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;technical parameters&lt;BR&gt;Rated working voltage 1140V; rated working current 630A; rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times; Rated current breaking frequency 3000 times; Mechanical lifespan of 15000 cycles;&lt;BR&gt;Rated short-time withstand current 12.5KA; rated short-time withstand time 4S; rated power frequency withstand voltage 10KV&lt;BR&gt;The rated opening distance of the contact is 4 &#177; 0.4mm; the self closing force of the contact is 115 &#177; 11N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;BR&gt;Equipped with circuit breakers ZK1-630.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;ZKTD-630/1140 Ceramic Vacuum Switch Tube Dimensions and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163848370.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 315px; HEIGHT: 371px&quot; border=0 hspace=0 alt=&quot;ZKTD-630/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421163848370.jpg&quot; width=315 height=371&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-500/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2239.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:47</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKTD-500/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;ZKTD-500/1140 ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=2 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 500A;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated short-circuit breaking current 9KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-circuit breaking frequency 16 times;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking frequency 3000 times;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Mechanical lifespan of 15000 cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-time withstand current 9KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand time of 4S;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated power frequency withstand voltage 10KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 100 &#177; 10N;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Equipped with circuit breaker ZN20-500 type.&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163727793.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 386px&quot; border=0 hspace=0 alt=&quot;ZKTD-500/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421163727793.jpg&quot; width=275 height=386&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-400/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2238.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:39</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTD-400/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 400A;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated short-circuit breaking current 8KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-circuit breaking frequency 16 times;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking frequency 3000 times;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Mechanical lifespan of 20000 cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-time withstand current 8KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand time of 4S;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated power frequency withstand voltage 10KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 115 &#177; 11N;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Equipped with circuit breaker ZN7-400 type.&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742116360155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTD-400/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/200742116360155.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160-630/10KV( ｉ type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2237.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ-160-630/10KV (I) ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;ZKTJ-160-630/10KV (I) ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;
&lt;P&gt;Rated working voltage 10KV;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated working current of 160, 250, 400, 630A;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Rated connection capacity 1.6, 2.5, 4, 6.3KA, 100 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated breaking capacity 1.28, 2, 3.2, 5.04KA, 25 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Ultimate breaking capacity 160-400A 4.5KA 3 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated short-time withstand current 1.28, 2, 3.2, 5.04KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Rated short-circuit duration 10S&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Power frequency withstand voltage 32KV;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Electric lifespan 100000 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Mechanical lifespan of 1 million cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Contact self closing force 85-125N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The reaction force at the rated opening distance of the contact is 100-130N;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;The contact resistance under the self closing force of the contact is less than 120 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Equipped with contactor CKG3-160-630A/10 type&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163432353.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 315px; HEIGHT: 354px&quot; border=0 hspace=0 alt=&quot;ZKTJ-160-630/10KV (ｉ) type ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421163432353.jpg&quot; width=315 height=354&gt;&lt;/A&gt;&lt;BR&gt;ZKTJ-160-630/10KV (ｉ) type ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-630/6KV( ｊ) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2236.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:21</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTJ-630/6KV (II) ceramic vacuum switch tube&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 6KV;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current 630A;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated connection capacity 6.3KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity 5.04KA, 3 times;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated short-time withstand current 5.04KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-term duration of 4S;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Power frequency withstand voltage 23KV;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Electric lifespan 100000 times&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The rated opening distance of the contact is 3 &#177; 0.3mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Contact self closing force 120 &#177; 12N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 130 &#177; 13N;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor ZN6-600 type.&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZKTJ-630/6KV (II) ceramic vacuum switch tube external dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742114515798.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-630/6KV (II) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742114515798.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160/6KV( ｊ) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2235.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical parameters&lt;BR&gt;Rated working voltage 6KV; rated working current 160A; rated connection capacity 1.6KA, 100 times&lt;BR&gt;Rated breaking capacity of 1.28KA, 25 times; Ultimate breaking capacity of 4.5KA, rated short-time withstand current of 1.28KA for 3 times;&lt;BR&gt;Rated short-circuit duration of 10 seconds; power frequency withstand voltage of 23KV; electrical life of 100000 times&lt;BR&gt;Mechanical lifespan of 1 million cycles; The rated opening distance of the contact is 3 &#177; 0.3mm; the self closing force of the contact is 85 &#177; 100N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 100 &#177; 10N&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次&lt;BR&gt;The allowable wear thickness of the contact is 1mm&lt;BR&gt;Equipped with CZG1-160 contactor. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421144717799.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 375px&quot; border=0 hspace=0 alt=&quot;ZKTJ-160/6KV (II) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421144717799.jpg&quot; width=275 height=375&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-630/6KV(1) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2234.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Purpose:&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters. &amp;nbsp;&lt;BR&gt;Technical parameters&lt;BR&gt;Rated working voltage 6KV; rated working current 630A; rated connection capacity 6.3KA, 100 times&lt;BR&gt;Rated breaking capacity 5.04KA, 25 times; Rated short-time withstand current 5.04KA; Rated short-circuit duration 10S;;&lt;BR&gt;Power frequency withstand voltage 23KV; electrical life 100000 times; Mechanical lifespan of 1 million cycles&lt;BR&gt;The rated opening distance of the contact is 3 &#177; 0.3mm; the self closing force of the contact is 125 &#177; 12.5mm; the reaction force at the rated opening distance of the contact is 130 &#177; 13N;&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次&lt;BR&gt;The allowable wear thickness of the contact is 1mm&lt;BR&gt;Equipped with contactor CKG3-630 type. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007421144536417.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-630/6KV (1) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421144536417.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKTJ-630/6KV (1) type ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160-400A/6KV(1) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2233.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:56</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;ZKTJ-160-400A/6KV (1) ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell, and high vacuum is used as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require contact maintenance. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;ZKTJ-160-400A/6KV (1) ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;P&gt;Rated working voltage 6KV;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;Rated working current 160-400A;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;Rated connection capacity 1.6~4KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Rated breaking capacity of 1.28-3.2KA, 25 times;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;Ultimate breaking capacity 4.5KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;Rated short-time withstand current 1.28-3.2KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;Power frequency withstand voltage 23KV;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;Electric lifespan 100000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;The rated opening distance of the contact is 3 &#177; 0.3mm;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;Contact self closing force 85-100N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The reaction force at the rated opening distance of the contact is 100 &#177; 120N;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The maximum mass of the switch tube is 1kg;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Equipped with contactor CKG3-160-400A type.&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;BR&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=5 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;&lt;A href=&quot;/uploadfiles/200704/2007421143853298.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 296px; HEIGHT: 396px&quot; border=0 hspace=0 alt=&quot;ZKTJ-160-400A/6KV (1) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421143853298.jpg&quot; width=296 height=396&gt;&lt;/A&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-600/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2232.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:47</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKTJ-600/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters. Single pole contactors will be particularly suitable for the renovation of street lamps and airport lighting control power departments.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTJ-600/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current 600A;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated connection capacity 6kA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity of 4.8KA, 25 times;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Ultimate breaking capacity 6KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand current 4.8KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Electrical lifespan AC4 5000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;The rated opening distance of the contact is 2.1 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 115 &#177; 11N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The maximum mass of the switch tube is 1kg;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor CKJ5-600 type.&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007421143635246.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-600/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421143635246.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-315 and 500/1140 ceramic vacuum switch tubes </title>
           <link>http://www.91way.com/info_en/2231.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:39</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;ZKTJ-315﹜ Technical parameters of 500/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=3 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated working current 315, 500A;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated connection capacity 3.15, 5kA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Rated breaking capacity 2.52KA, 4KA, 25 times;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Ultimate breaking capacity 5KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand current 3.15,5KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Electrical lifespan AC4 100000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Mechanical lifespan of 3 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;The rated opening distance of the contact is 2.0 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact self closing force 50 &#177; 5N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The reaction force at the rated opening distance of the contact is 65 &#177; 6.5N;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;39%&quot;&gt;Equipped with contactors VS317 and 507.&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZKTJ-315﹜ 500/1140 ceramic vacuum switch tube external dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742114339986.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 371px&quot; border=0 hspace=0 alt=&quot;ZKTJ-315﹜ 500/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/200742114339986.jpg&quot; width=275 height=371&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-400/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2230.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKTJ-400/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTJ-400/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=3 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 400A;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated connection capacity 4KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity of 3.2KA, 25 times;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Ultimate breaking capacity 4.5KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated short-time withstand current 3.2KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Electrical lifespan AC4 60000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;The rated opening distance of the contact is 2.0 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Contact self closing force 100 &#177; 10N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 125 &#177; 12N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The maximum mass of the switch tube is 0.75kg;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor CKJ5-400 type.&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007421143013968.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-400/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421143013968.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;ZKTJ-400/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-300/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2229.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZKTJ-300/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;The ZKTJ-300/1140 ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;Rated working voltage 1140V; rated working current 300A; rated connection capacity 3KA, 100 times&lt;BR&gt;Rated breaking capacity 2.4KA, 25 times; Ultimate breaking capacity of 4.5KA, rated short-time withstand current of 2.4KA for 3 times;&lt;BR&gt;Rated short-circuit duration of 10 seconds; power frequency withstand voltage of 10KV; electrical life of AC46000 times&lt;BR&gt;Mechanical lifespan of 1 million cycles; The rated opening distance of the contact is 2.0 &#177; 0.2mm; the self closing force of the contact is 50 &#177; 5N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 65 &#177; 6.5N;&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;BR&gt;The allowable wear thickness of the contact is 1mm;&lt;BR&gt;The maximum mass of the switch tube is 0.5Kg;&lt;BR&gt;Equipped with CJZ 300 contactor.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421142737285.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-300/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421142737285.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-250/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2228.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:13</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=2 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current 250A;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated connection capacity 2.5KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity of 2KA, 25 times;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Ultimate breaking capacity 4.5KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand current of 2KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Electrical lifespan AC4 60000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;The rated opening distance of the contact is 2.0 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 50 &#177; 5N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 65 &#177; 6.5N;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The maximum mass of the switch tube is 0.5Kg;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor CKJ5-250 type.&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZKTJ-250/1140 Ceramic Vacuum Switch Tube Dimensions and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007421142550268.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-250/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421142550268.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;ZKTJ-250/1140 Ceramic Vacuum Switch Tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-200/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2227.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:15:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Purpose:&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters. &amp;nbsp;&lt;BR&gt;Technical parameters&lt;BR&gt;Rated working voltage 1140V; rated working current 200A; rated connection capacity 2KA, 100 times&lt;BR&gt;Rated breaking capacity 1.6KA, 25 times; Ultimate breaking capacity of 4.5KA, rated short-time withstand current of 1.6KA for 3 times;&lt;BR&gt;Rated short-circuit duration of 10 seconds; power frequency withstand voltage of 10KV; electrical life of AC46000 times&lt;BR&gt;Mechanical lifespan of 1 million cycles; The rated opening distance of the contact is 2.0 &#177; 0.2mm; the self closing force of the contact is 50 &#177; 5N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 65 &#177; 6.5N&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次&lt;BR&gt;The allowable wear thickness of the contact is 1mm&lt;BR&gt;The maximum mass of the switch tube is 0.5Kg&lt;BR&gt;Equipped with CJZ-200 contactor. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;ZKTJ-200/1140 ceramic vacuum switch tube external dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421142135149.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 383px&quot; border=0 hspace=0 alt=&quot;ZKTJ-200/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421142135149.jpg&quot; width=275 height=383&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-125/1140( ｊ) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2226.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:14:56</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;ZKTJ-125/1140 (II) ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;B&gt;&lt;FONT color=#000066&gt;&lt;BR&gt;&lt;/B&gt;&lt;/FONT&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current 125A;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated connection capacity 1.25KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity 1KA. 25 times;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Ultimate breaking capacity 2.5KA, 3 times&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand current 1KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Electrical lifespan: 46000 cycles per AC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;The rated opening distance of the contact is 1.8 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 20 &#177; 3N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 45 &#177; 5N;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The maximum mass of the switch tube is 0.3KG;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor CKj5-125 (ii) type;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-125/1140(I)  type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2225.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:14:47</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;ZKTJ-125/1140 (I) ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated working current 125A;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated connection capacity 1.25KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;Rated breaking capacity 1KA. 25 times;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Ultimate breaking capacity 2. 5KAㄛ 3 times&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated short-time withstand current 1KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;Rated short-circuit duration of 10S;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Power frequency withstand voltage 10KV;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;Electrical lifespan: 46000 cycles per AC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;The rated opening distance of the contact is 1.8 &#177; 0.2mm;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;Contact self closing force 20 &#177; 3N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;The reaction force at the rated opening distance of the contact is 45 &#177; 5N;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under contact self closing force ≒ 120;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;The maximum mass of the switch tube is 0. 3KG˙&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with contactor CKj5-125 (I) type;&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742192729790.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 248px; HEIGHT: 296px&quot; border=0 hspace=0 alt=&quot;ZKTJ-125/1140 (I) Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/200742192729790.jpg&quot; width=248 height=296&gt;&lt;/A&gt;&lt;BR&gt;ZKTJ-125/1140 (I) type ceramic vacuum switch tube&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/2500-40C/R Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/1377.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:14:38</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Ceramic vacuum arc extinguishing chamber for TD34-12/2500-40C/R vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
