<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Phase relay</title>
       <link>http://www.91way.com</link>
       <description>Phase relay</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:16:38</pubDate>
       <item>
           <title>[Phase relay]APR-V4 Under reverse phase protection relay </title>
           <link>http://www.91way.com/info_en/25622.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-14 10:58:00</pubDate>
           <comments></comments>
           <description>APR-V4 under reverse phase protection relay&lt;BR&gt;&lt;BR&gt;Can confirm the phase sequence of the three-phase power supply to prevent motor reversal&lt;BR&gt;Wiring according to the diagram can prevent the electromagnetic contactor from operating in case of phase loss&lt;BR&gt;This protective relay adopts a voltage output method that is independent of the load current&lt;BR&gt;Low voltage protection range 20%&lt;BR&gt;Three phase four wire type&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;model&lt;/TD&gt;
&lt;TD align=center&gt;APR-V4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;AC(V):220,380,50/60Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Output contact&lt;/TD&gt;
&lt;TD align=center&gt;1C 5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Indicator light action&lt;/TD&gt;
&lt;TD align=center&gt;TRIP-UP two indicator lights&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=29 align=center&gt;
&lt;P&gt;longevity&lt;/P&gt;
&lt;P&gt;fate&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76 align=center&gt;Mechanics&lt;/TD&gt;
&lt;TD align=center&gt;5&#215;10^6 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Electrical&lt;/TD&gt;
&lt;TD align=center&gt;10^5 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Setting error&lt;/TD&gt;
&lt;TD align=center&gt;--&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Return time&lt;/TD&gt;
&lt;TD align=center&gt;300~600 msec&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;power consumption&lt;/TD&gt;
&lt;TD align=center&gt;2VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Environmental temperature for use&lt;/TD&gt;
&lt;TD align=center&gt;-10¡æ~+55¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Environmental humidity for use&lt;/TD&gt;
&lt;TD align=center&gt;45%~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;weight&lt;/TD&gt;
&lt;TD align=center&gt;Approx.130g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;APR-V4 under reverse phase protection relay wiring diagram and timing diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140611173456469.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 227px; WIDTH: 603px; FILTER: none&quot; border=0 hspace=0 alt=&quot;APR-V4 under reverse phase protection relay wiring diagram&quot; src=&quot;/upload2014/201406/20140611173456469.jpg&quot; width=603 height=227&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Appearance dimension diagram of APR-V4 under reverse phase protection relay&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140611173506232.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 133px; WIDTH: 457px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of APR-V4 under reverse phase protection relay&quot; src=&quot;/upload2014/201406/20140611173506232.jpg&quot; width=457 height=133&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;APR-V4 under reverse phase protection relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]APR-4,APR-4L Under reverse phase protection relay </title>
           <link>http://www.91way.com/info_en/25602.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-14 10:57:50</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2 align=center&gt;model&lt;/TD&gt;
&lt;TD width=234 align=center&gt;APR-4, APR-4VM&lt;/TD&gt;
&lt;TD width=251 align=center&gt;APR-4L&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;P&gt;AC(V):220,240,380,415,440,480,50/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD align=center&gt;AC(V):110~480V,50/60Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Output contact&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;1C 5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Indicator light action&lt;/TD&gt;
&lt;TD align=center&gt;Power on indication&lt;/TD&gt;
&lt;TD align=center&gt;Two indicator lights&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=29 align=center&gt;
&lt;P&gt;longevity&lt;BR&gt;fate&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76 align=center&gt;Mechanics&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;5&#215;10^6 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Electrical&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;10^5 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Setting error&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;--&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Return time&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;3 sec&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;power consumption&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;2VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Environmental temperature for use&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;-10¡æ~+55¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Environmental humidity for use&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;45%~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;weight&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;Approx.130g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;APR-4, APR-4L under reverse phase protection relay wiring diagram and timing diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140610182026817.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 213px; WIDTH: 604px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Phase sequence diagram of APR-4, APR-4L under reverse phase protection relay&quot; src=&quot;/upload2014/201406/20140610182026817.jpg&quot; width=604 height=213&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Appearance dimension diagram of APR-4, APR-4L under reverse phase protection relay&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140610182039124.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 139px; WIDTH: 465px; FILTER: none&quot; border=0 hspace=0 alt=&quot;APR-4, APR-4L under reverse phase protection relay external dimensions&quot; src=&quot;/upload2014/201406/20140610182039124.jpg&quot; width=465 height=139&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;APR-4, APR-4L under reverse phase protection relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]LXB-1E Type Current Phase Comparison Relay </title>
           <link>http://www.91way.com/info_en/20177.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-14 10:01:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The LXB-1E current phase comparison relay is used as a selection element in phase comparison bus differential protection circuits.&lt;BR&gt;&lt;BR&gt;Technical requirements for LXB-1E current phase comparison relay&lt;BR&gt;1. The rated current IH is 1A, 5A, and the rated frequency is 50-60Hz.&lt;BR&gt;When Ic and Im are greater than IH and less than 30IH, the action zone is 140o~180o, with no repeated action zone.&lt;BR&gt;3. The maximum sensitivity angle is 0o &#177; 4o, 180o &#177; 4o.&lt;BR&gt;Under the condition of maximum sensitivity angle, when any current changes within 30IH, the starting current shall not exceed 0.5IH.&lt;BR&gt;5. Under the condition of maximum sensitivity angle, when Ic, Im, is not less than IH, the action time shall not exceed 40ms.&lt;BR&gt;When Ic and Im are both IH, the total power consumption of the relay shall not exceed 1.5VA.&lt;BR&gt;In a DC inductive load circuit with a voltage not exceeding 220V and a current not exceeding 0.2A (time constant of 5 &#215; 10-3S), the contact breaking capacity is 10W; in an AC circuit, it is 20VA.&lt;BR&gt;The weight of the relay is approximately 2.1kg.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120820144547359.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 574px; HEIGHT: 582px&quot; border=0 hspace=0 alt=&quot;Electrical principle and wiring diagram of LXB-1E current phase comparison relay&quot; src=&quot;/upload2012/201208/20120820144547359.jpg&quot; width=574 height=582&gt;&lt;/A&gt;&lt;BR&gt;LXB-1E type current phase comparison relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]LXB-4 Type Current Phase Comparison Relay </title>
           <link>http://www.91way.com/info_en/20176.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-14 10:01:27</pubDate>
           <comments></comments>
           <description>1. Purpose:&lt;BR&gt;The LXB-4 current phase comparison relay is used as a selection element in phase comparison type bus differential protection devices.&lt;BR&gt;2. Structural characteristics&lt;BR&gt;Principle of rectification type absolute value comparison formula.&lt;BR&gt;&lt;BR&gt;3. Main technical data of LXB-4 current phase comparison relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;rated&lt;/P&gt;
&lt;P align=center&gt;current&lt;/P&gt;
&lt;P align=center&gt;In&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Action Zone&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;maximum&lt;/P&gt;
&lt;P align=center&gt;sensitive&lt;/P&gt;
&lt;P align=center&gt;corner&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;start&lt;/P&gt;
&lt;P align=center&gt;current&lt;/P&gt;
&lt;P align=center&gt;(A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;action&lt;/P&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;(s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;power&lt;/P&gt;
&lt;P align=center&gt;consume&lt;/P&gt;
&lt;P align=center&gt;(VA)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;Contact breakage&lt;/P&gt;
&lt;P align=center&gt;Open capacity&lt;/P&gt;
&lt;P align=center&gt;(W)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;weight&lt;/P&gt;
&lt;P align=center&gt;(kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81&gt;
&lt;P align=center&gt;Overall dimensions&lt;/P&gt;
&lt;P align=center&gt;(max) Length x&lt;/P&gt;
&lt;P align=center&gt;width &#215; height&lt;/P&gt;
&lt;P align=center&gt;(mm)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;5A&lt;/P&gt;
&lt;P align=center&gt;(50Hz)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Ic and Im&amp;gt;&lt;/P&gt;
&lt;P align=center&gt;In£¼20In&lt;/P&gt;
&lt;P align=center&gt;Time&amp;gt;140&lt;SUP&gt;o&lt;/SUP&gt;£¼180&lt;SUP&gt;o&lt;/SUP&gt;No repetitive action area&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;2J&lt;/P&gt;
&lt;P align=center&gt;0&lt;SUP&gt;o&lt;/SUP&gt;&#177;&lt;/P&gt;
&lt;P align=center&gt;ten&lt;SUP&gt;o&lt;/SUP&gt;&lt;/P&gt;
&lt;P align=center&gt;1J&lt;/P&gt;
&lt;P align=center&gt;one hundred and eighty&lt;SUP&gt;o&lt;/SUP&gt;&lt;/P&gt;
&lt;P align=center&gt;&#177;10&lt;SUP&gt;o&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Maximum sensitivity&lt;/P&gt;
&lt;P align=center&gt;Under the corner, when&lt;/P&gt;
&lt;P align=center&gt;Any current&lt;/P&gt;
&lt;P align=center&gt;In 20in&lt;/P&gt;
&lt;P align=center&gt;Internal changes&lt;/P&gt;
&lt;P align=center&gt;one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Ic¡¢Im¡Ý&lt;/P&gt;
&lt;P align=center&gt;5A, Ic, and&lt;/P&gt;
&lt;P align=center&gt;Im phase&lt;/P&gt;
&lt;P align=center&gt;The difference is 0&lt;SUP&gt;o&lt;/SUP&gt;and&lt;/P&gt;
&lt;P align=center&gt;one hundred and eighty&lt;SUP&gt;o&lt;/SUP&gt;&lt;/P&gt;
&lt;P align=center&gt;¡Ü0.035&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=60&gt;
&lt;P align=center&gt;The current is&lt;/P&gt;
&lt;P align=center&gt;5A¡Ü2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;DC has&lt;/P&gt;
&lt;P align=center&gt;Sensing circuit&lt;/P&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;About 4&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=81&gt;
&lt;P align=center&gt;226&#215;124&lt;/P&gt;
&lt;P align=center&gt;&#215;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4. Principle wiring diagram of LXB-4 current phase comparison relay&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120820140305311.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 635px; HEIGHT: 357px&quot; border=0 hspace=0 alt=&quot;Electrical principle and wiring diagram of LXB-4 current phase comparison relay&quot; src=&quot;/upload2012/201208/20120820140305311.jpg&quot; width=635 height=357&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]DHC-X series phase loss and phase sequence protection relay </title>
           <link>http://www.91way.com/info_en/7635.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-13 19:41:11</pubDate>
           <comments></comments>
           <description>The DHC X series phase loss and phase sequence protection relay is used in conjunction with an AC contactor for the phase mismatch of three-phase power supplies in AC 380V Lack of phase Motor protection against phase voltage imbalance and overvoltage/undervoltage&lt;BR&gt;&lt;BR&gt;Adopting voltage sampling method It is independent of the power of the motor&lt;BR&gt;Series products There are multiple different functions to choose from To achieve different protection purposes&lt;BR&gt;Installation method of guide rail International standard installation dimensions&lt;BR&gt;SMT process&lt;BR&gt;Reliable performance Beautiful appearance High performance price ratio&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;function&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DHC1X&lt;/DIV&gt;
&lt;DIV align=center&gt;Phase sequence protector (RSTC)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DHC2X&lt;/DIV&gt;
&lt;DIV align=center&gt;3-phase 3-wire phase sequence protector for phase loss&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DHC2X-T&lt;/DIV&gt;
&lt;DIV align=center&gt;3-phase 3-wire phase sequence protector for phase loss&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DHC2X-N&lt;/DIV&gt;
&lt;DIV align=center&gt;3-phase 4-wire phase sequence protector with missing phase&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DHC1X-T&lt;/DIV&gt;
&lt;DIV align=center&gt;Phase voltage phase sequence protector (RSTB)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;A href=&quot;/upload2009/200910/2009102810255526.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 270px; WIDTH: 90px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of DHC-X series phase loss and phase sequence protection relay&quot; src=&quot;/upload2009/200910/2009102810255526.jpg&quot; width=90 height=270&gt;&lt;/A&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;A href=&quot;/upload2009/200910/20091028102512262.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 180px; WIDTH: 90px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of DHC-X series phase loss and phase sequence protection relay&quot; src=&quot;/upload2009/200910/20091028102512262.jpg&quot; width=90 height=180&gt;&lt;/A&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;A href=&quot;/upload2009/200910/20091028102520459.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 162px; WIDTH: 90px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 3 of DHC-X series phase loss and phase sequence protection relay&quot; src=&quot;/upload2009/200910/20091028102520459.jpg&quot; width=90 height=162&gt;&lt;/A&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;A href=&quot;/upload2009/200910/20091028102526463.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 168px; WIDTH: 90px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 4 of DHC-X series phase loss and phase sequence protection relay&quot; src=&quot;/upload2009/200910/20091028102526463.jpg&quot; width=90 height=168&gt;&lt;/A&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;A href=&quot;/upload2009/200910/20091028102532521.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 205px; WIDTH: 90px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 5 of DHC-X series phase loss and phase sequence protection relay&quot; src=&quot;/upload2009/200910/20091028102532521.jpg&quot; width=90 height=205&gt;&lt;/A&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Phase sequence error&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Immediate action&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Immediate action&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Immediate action&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Immediate action&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Immediate action&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Failed to start due to phase loss&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Phase loss and disconnection&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;10% overvoltage/undervoltage detection&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì Voltage fine-tuning is available&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;3 phases and 3 wires&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;3 phases and 4 wires&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ì&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Sensitivity adjustment&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10% fixed&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5%~20%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5%~20%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;action delay&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.1S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1-10S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1-10S&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV&gt;Applicable to&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Phase sequence error protection. It can also be used for three-phase phase loss protection of motors that start frequently&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;It is a simplified version of DHC2X-T's features&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Phase sequence error protection and phase loss protection for 3-phase 3-wire motors&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Phase sequence error protection and phase loss protection for 3-phase 4-wire motors&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Three phase imbalance, undervoltage, overvoltage, and undervoltage and overvoltage protection for each phase. And phase loss protection&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Phase relay]LXB-2A Current phase comparison relay </title>
           <link>http://www.91way.com/info_en/3760.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-13 19:16:53</pubDate>
           <comments></comments>
           <description>LXB-2A Current Phase Comparison Relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;rated value&lt;/TD&gt;
&lt;TD colSpan=2&gt;Angle characteristics&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Starting current (A)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Action time (s)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;power&lt;BR&gt;Consumption (VA)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Contact disconnection&lt;BR&gt;Capacity DC (W)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;return&lt;BR&gt;coefficient&lt;/TD&gt;
&lt;TD rowSpan=2&gt;weight&lt;BR&gt;(kg)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;(A)&lt;/TD&gt;
&lt;TD&gt;(Hz)&lt;/TD&gt;
&lt;TD&gt;rated current&lt;BR&gt;Action Zone&lt;/TD&gt;
&lt;TD&gt;50 or 100&lt;BR&gt;A Time Zone&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;five&lt;BR&gt;one&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;¡Ý140&#176;&lt;/TD&gt;
&lt;TD&gt;¡Ü180&#176;&lt;/TD&gt;
&lt;TD&gt;¡Ü 0.2 times&lt;BR&gt;rated current&lt;/TD&gt;
&lt;TD&gt;¡Ü0.035&lt;/TD&gt;
&lt;TD&gt;¡Ü2&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;¡Ý0.035&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008525105336271.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 312px; WIDTH: 434px; FILTER: none&quot; border=0 hspace=0 alt=&quot;LXB-2A Current Phase Comparison Relay Wiring Diagram&quot; src=&quot;/uploadfiles/200805/2008525105336271.gif&quot; width=434 height=312&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;LXB-2A Current Phase Comparison Relay&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]LXB-1A Type Current Phase Comparison Relay </title>
           <link>http://www.91way.com/info_en/3759.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-13 19:16:45</pubDate>
           <comments></comments>
           <description>LXB-1A Type Current Phase Comparison Relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;HEIGHT: 229px; WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; height=229 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;rated value&lt;/TD&gt;
&lt;TD colSpan=2&gt;Minimum operating current (A)&lt;/TD&gt;
&lt;TD rowSpan=2 width=62&gt;Action time (ms)&lt;/TD&gt;
&lt;TD rowSpan=2 width=41&gt;contact form &lt;/TD&gt;
&lt;TD rowSpan=2 width=69&gt;Contact breaking capacity (W)&lt;/TD&gt;
&lt;TD colSpan=2&gt;power consumption&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97&gt;AC voltage (V)&lt;/TD&gt;
&lt;TD width=41&gt;AC current (A)&lt;/TD&gt;
&lt;TD width=41&gt;DC voltage (V)&lt;/TD&gt;
&lt;TD width=74&gt;lz=0&lt;BR&gt;Uz=0&lt;/TD&gt;
&lt;TD width=129&gt;lz=0&lt;BR&gt;Uz=100V&lt;/TD&gt;
&lt;TD width=72&gt;AC Circuit (VA)&lt;/TD&gt;
&lt;TD width=80&gt;DC circuit (W)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97&gt;one hundred&lt;BR&gt;fifty-seven&lt;BR&gt;(50Hz)&lt;/TD&gt;
&lt;TD width=41&gt;five&lt;BR&gt;&lt;BR&gt;one&lt;/TD&gt;
&lt;TD width=41&gt;two hundred and twenty&lt;BR&gt;one hundred and ten&lt;BR&gt;forty-eight&lt;/TD&gt;
&lt;TD width=74&gt;2.4-2.7&lt;/TD&gt;
&lt;TD width=129&gt;7-9&lt;/TD&gt;
&lt;TD width=62&gt;When lz=0&lt;BR&gt;Uz=0&lt;BR&gt;When ld ¡Ý 8A ¡Ü 30&lt;/TD&gt;
&lt;TD width=41&gt;2 pairs of dynamic combination&lt;/TD&gt;
&lt;TD width=69&gt;DC inductive circuit 25W AC circuit 30VA&lt;/TD&gt;
&lt;TD width=72&gt;Each current circuit ¡Ü 1 and voltage circuit ¡Ü 0.5&lt;/TD&gt;
&lt;TD width=80&gt;220V,6&lt;BR&gt;110V,4&lt;BR&gt;48V,2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008525105150888.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 426px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of LXB-1A current phase comparison relay&quot; src=&quot;/uploadfiles/200805/2008525105150888.gif&quot; width=600 height=426&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008525105159306.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 306px; WIDTH: 438px; FILTER: none&quot; border=0 hspace=0 alt=&quot;LXB-1A Type Current Phase Comparison Relay Wiring Diagram&quot; src=&quot;/uploadfiles/200805/2008525105159306.gif&quot; width=438 height=306&gt;&lt;/A&gt;&lt;BR&gt;LXB-1A Type Current Phase Comparison Relay&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Phase relay]BXX-2 Type Phase Sequence Relay </title>
           <link>http://www.91way.com/info_en/2417.html</link>
           <author></author>
           <guid></guid>
           <category>Phase relay</category>
           <pubDate>2026-6-13 18:49:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/20079822103185.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 892px; WIDTH: 474px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of BXX-2 phase sequence relay&quot; src=&quot;/uploadfiles/200709/20079822103185.gif&quot; width=474 height=892&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;BXX-2 phase sequence relay is mainly used for phase sequence detection or phase failure protection. When the phase sequence is correct, the relay operates to obtain output; When the phase sequence is incorrect or any phase of the AC circuit is disconnected, the relay will lock.&lt;BR&gt;2. Structure and Working Principle&lt;BR&gt;The relay adopts JK-11K, H, and Q type housing, and its external dimensions, rear terminals, and installation opening diagram are shown in Appendix 3. The back terminal is shown in Figure 1.&lt;BR&gt;&lt;BR&gt;Figure 1 Rear terminal wiring&lt;BR&gt;The relay consists of a small sealed relay, bridge rectifier, integrated block, transistor, voltage regulator, resistor, capacitor and other components.&lt;BR&gt;3. Technical requirements&lt;BR&gt;1. Rated value&lt;BR&gt;The rated line voltage of the relay is 380V, and the rated frequency is 50Hz.&lt;BR&gt;2. Voltage fluctuations&lt;BR&gt;The allowable fluctuation range of relay voltage is 80% to 110% of the rated value.&lt;BR&gt;3. Phase sequence judgment&lt;BR&gt;When the phase sequence is correct, the relay operates. When the phase sequence is incorrect, the relay locks. When any phase in the three phases is disconnected, the relay locks and the LED lights up.&lt;BR&gt;4. Power consumption&lt;BR&gt;The total power consumption of the three phases shall not exceed 4VA.&lt;BR&gt;5. The insulation resistance should not be less than 300M ¦¸.&lt;BR&gt;6. Dielectric strength&lt;BR&gt;Under standard test atmospheric conditions, the conductive circuits of the relay should be able to withstand a test voltage of 2kV (effective value) AC for 1 minute without insulation breakdown or flashover between the exposed non charged metal parts and the casing, as well as between the AC circuit and the contact circuit.&lt;BR&gt;7. Contact performance&lt;BR&gt;In the DC inductive (¦Ó=5ms) circuit, U ¡Ü 250V, I ¡Ü 0.2A, 30W; in the AC (cos ¦Õ=0.4) circuit, U¡Ü250V£¬I¡Ü0.5A£¬ It is 100VA.&lt;BR&gt;8. The long-term allowable closing current of the contact is 1A.&lt;BR&gt;The electrical lifespan of the relay is 5 &#215; 103 times, and the mechanical lifespan is 104 times.&lt;BR&gt;The weight of the relay is approximately 0.7kg.&lt;BR&gt;4. Ordering Notice&lt;BR&gt;Please specify the product model, name, rated line voltage, and installation method when placing an order.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>