       <item>
           <title>[Motor protector]GV2-ME32-101 type motor protector </title>
           <link>http://www.91way.com/info_en/26836.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:49</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150325192333269.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 836px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GV2-ME32-101 motor protector&quot; src=&quot;/upload2015/201503/20150325192333269.jpg&quot; width=670 height=836&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150325192345866.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 1192px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GV2-ME32-101 motor protector&quot; src=&quot;/upload2015/201503/20150325192345866.jpg&quot; width=670 height=1192&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GV2-ME32-101 motor protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]GV2-RS32-1 type motor protector </title>
           <link>http://www.91way.com/info_en/26835.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:40</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150325191924458.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 1095px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GV2-RS32-1 motor protector&quot; src=&quot;/upload2015/201503/20150325191924458.jpg&quot; width=670 height=1095&gt;&lt;/A&gt;&lt;BR&gt;GV2-RS32-1 motor protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]GV2-ME80-1 type motor protector </title>
           <link>http://www.91way.com/info_en/26834.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:32</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150325191552324.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 445px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of GV2-ME80-1 motor protector&quot; src=&quot;/upload2015/201503/20150325191552324.jpg&quot; width=670 height=445&gt;&lt;/A&gt;&lt;BR&gt;GV2-ME80-1 motor protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]CB1 series control and protection switchgear </title>
           <link>http://www.91way.com/info_en/26218.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:23</pubDate>
           <comments></comments>
           <description>The CB1 series control and protection switchgear (hereinafter referred to as CB1) integrates the main functions of circuit breakers, contactors, overload relays, and isolators. It has high short-circuit breaking capacity, long service life, good coordination and cooperation characteristics, complete protection functions, high intelligence level, simplified system design, easy installation and debugging, and energy-saving and material saving. It effectively reduces the types, specifications, and quantities of products in motor control systems, solves the problem of coordination and cooperation characteristics between discrete components, and is an ideal basic element in low-voltage distribution and control systems.&lt;BR&gt;&lt;BR&gt;The CB1 series control and protection switchgear is mainly used for the control and protection of electric motors with AC 50Hz, rated working voltages of 400V and 690V, and rated currents ranging from 0.15A to 125A. It is suitable for frequent operation control and can connect, carry, and disconnect currents under normal conditions, including specified operating overload conditions. It can also connect and disconnect currents under specified abnormal conditions, such as short-circuit currents, within a specified time.&lt;BR&gt;&lt;BR&gt;CB1 series rated working voltage AC400, 690V/50Hz&lt;BR&gt;CB1 series rated working current 12A, 32A, 125A&lt;BR&gt;The CB1 series has three poles&lt;BR&gt;The CB1 series has isolation function&lt;BR&gt;The CB1 series is classified as AC-43&lt;BR&gt;The CB1 series has isolation function&lt;BR&gt;The CB1 series meets the following standards&lt;BR&gt;IEC60947-1 and GB 14048.1 General Provisions&lt;BR&gt;IEC60947-6-2 and GB 14048.9 Control and Protection Switchgear (Equipment)&lt;BR&gt;The CB1 series control and protection switchgear has obtained the national mandatory product certification CCC mark.&lt;BR&gt;&lt;BR&gt;2. Normal usage conditions&lt;BR&gt;The ambient air temperature ranges from -5 ¡æ to+40 ¡æ, and the average value over 24 hours does not exceed+35 ¡æ;&lt;BR&gt;The altitude of the installation site shall not exceed 2000m;&lt;BR&gt;The relative humidity of the air shall not exceed 50% at a maximum temperature of+40 ¡æ; Higher relative humidity is allowed at lower temperatures, such as reaching 90% at 20 ¡æ. Special measures should be taken for occasional condensation caused by temperature changes;&lt;BR&gt;The pollution level is level 3;&lt;BR&gt;The installation category of the main circuit is III, and the auxiliary control circuit is II;&lt;BR&gt;The CB1 series should be installed in a location that is free from explosive hazards, conductive dust, and is not capable of corroding metals or damaging insulation.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=310 colSpan=3&gt;project&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;technical parameters&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=310 colSpan=3&gt;model&lt;/TD&gt;
&lt;TD width=253 colSpan=4&gt;CB1-12&lt;/TD&gt;
&lt;TD width=107 colSpan=2&gt;CB1-32&lt;/TD&gt;
&lt;TD&gt;CB1-63&lt;/TD&gt;
&lt;TD&gt;CB1-125&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=10 width=490&gt;main circuit&lt;/TD&gt;
&lt;TD width=261 colSpan=2&gt;Agreed free air heating current Ith (A)&lt;/TD&gt;
&lt;TD width=253 colSpan=4&gt;twelve&lt;/TD&gt;
&lt;TD width=107 colSpan=2&gt;thirty-two&lt;/TD&gt;
&lt;TD&gt;sixty-three&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Rated working current Ie (A)&lt;/TD&gt;
&lt;TD width=253 colSpan=4&gt;twelve&lt;/TD&gt;
&lt;TD width=107 colSpan=2&gt;thirty-two&lt;/TD&gt;
&lt;TD&gt;sixty-three&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Usage category&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;AC-43&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Rated working voltage Ue (V)&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;AC400£¬690/AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Rated insulation voltage Ui (V)&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;six hundred and ninety&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Rated impulse withstand voltage Uimp (kV)&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;six&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;polar number&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=197&gt;Rated operating short-circuit breaking capacity Ics (kA)&lt;/TD&gt;
&lt;TD width=64&gt;AC400V&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=64&gt;AC690V&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;four&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Total cutoff time (ms)&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=105 rowSpan=5 width=49&gt;Intelligent controller (release device)&lt;/TD&gt;
&lt;TD width=261 colSpan=2&gt;Rated current of release device Iet (A)&lt;/TD&gt;
&lt;TD width=73&gt;zero point six&lt;/TD&gt;
&lt;TD width=73&gt;one point four&lt;/TD&gt;
&lt;TD width=60&gt;five&lt;/TD&gt;
&lt;TD width=47&gt;twelve&lt;/TD&gt;
&lt;TD width=60&gt;eighteen&lt;/TD&gt;
&lt;TD width=47&gt;thirty-two&lt;/TD&gt;
&lt;TD&gt;sixty-three&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Set current range Ir1 (A)&lt;/TD&gt;
&lt;TD width=73&gt;0.15~0.6&lt;/TD&gt;
&lt;TD width=73&gt;0.35~1.4&lt;/TD&gt;
&lt;TD width=60&gt;1.25~5&lt;/TD&gt;
&lt;TD width=47&gt;3~12&lt;/TD&gt;
&lt;TD width=60&gt;4.5~18&lt;/TD&gt;
&lt;TD width=47&gt;8~32&lt;/TD&gt;
&lt;TD&gt;32~63&lt;/TD&gt;
&lt;TD&gt;63~125&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Code for setting current range&lt;/TD&gt;
&lt;TD width=73&gt;R1&lt;/TD&gt;
&lt;TD width=73&gt;R2&lt;/TD&gt;
&lt;TD width=60&gt;R3&lt;/TD&gt;
&lt;TD width=47&gt;R4&lt;/TD&gt;
&lt;TD width=60&gt;S1&lt;/TD&gt;
&lt;TD width=47&gt;S2&lt;/TD&gt;
&lt;TD&gt;T&lt;/TD&gt;
&lt;TD&gt;U&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=197&gt;The maximum rated power Pe (kW) of the controlled motor corresponding to Iet&lt;/TD&gt;
&lt;TD width=64&gt;AC400V&lt;/TD&gt;
&lt;TD width=73&gt;zero point one two&lt;/TD&gt;
&lt;TD width=73&gt;zero point three seven&lt;/TD&gt;
&lt;TD width=60&gt;one point five&lt;/TD&gt;
&lt;TD width=47&gt;five point five&lt;/TD&gt;
&lt;TD width=60&gt;seven point five&lt;/TD&gt;
&lt;TD width=47&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;fifty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=64&gt;AC690V&lt;/TD&gt;
&lt;TD width=73&gt;zero point two five&lt;/TD&gt;
&lt;TD width=73&gt;zero point seven five&lt;/TD&gt;
&lt;TD width=60&gt;three&lt;/TD&gt;
&lt;TD width=47&gt;seven point five&lt;/TD&gt;
&lt;TD width=60&gt;eleven&lt;/TD&gt;
&lt;TD width=47&gt;twenty-two&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=168 rowSpan=8 width=49&gt;Control characteristics&lt;/TD&gt;
&lt;TD width=261 colSpan=2&gt;Rated control power supply voltage Us (V)&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;AC230/AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Maximum power consumption (W)&lt;/TD&gt;
&lt;TD width=360 colSpan=6&gt;four&lt;/TD&gt;
&lt;TD colSpan=2&gt;seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=197&gt;Action time (ms)&lt;/TD&gt;
&lt;TD width=64&gt;close&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;&amp;lt;85&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=64&gt;disconnect&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;&amp;lt;75&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Mechanical lifespan (10000 cycles)&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;one thousand and two hundred&lt;/TD&gt;
&lt;TD&gt;five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=197&gt;Electrical lifespan (AC-43) (10000 cycles)&lt;/TD&gt;
&lt;TD width=64&gt;AC690V&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=64&gt;AC400V&lt;/TD&gt;
&lt;TD width=253 colSpan=4&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD width=107 colSpan=2&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD align=right&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;Operating frequency (times/h)&lt;/TD&gt;
&lt;TD width=360 colSpan=6&gt;1200 (load factor of 40%)&lt;/TD&gt;
&lt;TD&gt;600 (load factor of 40%)&lt;/TD&gt;
&lt;TD&gt;1200 (load factor of 25%)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=49&gt;auxiliary contact&lt;/TD&gt;
&lt;TD width=261 colSpan=2&gt;Output quantity&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;ZA controller: 3NO3NC; ZL, ZP, ZM, ZF, EJ, EF, ES controllers: 1NO1NC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=261 colSpan=2&gt;output capacity&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;See sample for details&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=246 colSpan=2&gt;Shell protection level&lt;/TD&gt;
&lt;TD width=64&gt;front panel&lt;/TD&gt;
&lt;TD width=536 colSpan=8&gt;IP40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=64&gt;Wiring area&lt;/TD&gt;
&lt;TD width=448 colSpan=7&gt;IP20&lt;/TD&gt;
&lt;TD&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=69&gt;
&lt;TD height=69 width=670 colSpan=9&gt;Note 1: When the rated working voltage is AC690V, a phase partition should be used;&lt;BR&gt;Note 2: At AC690V, the maximum operating currents of CB1-32 and 63 are 21A and 45A, respectively. The controller setting current Ir1 should not exceed the maximum operating current;&lt;BR&gt;Note 3: EJ, EF, and ES controllers are applicable to CB1-12 and 32.&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Motor protector]CD4 series motor control protector </title>
           <link>http://www.91way.com/info_en/26217.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:15</pubDate>
           <comments></comments>
           <description>Mainly used for the protection and control of motors with rated operating voltage up to 690V and rated current ranging from 1.25 to 450A.&lt;BR&gt;It has multiple control functions: direct start, Y/¡÷ step-down start, resistance step-down start, autotransformer step-down start, reversible commutation start, and dual speed start&lt;BR&gt;Communication function, using Modbus RTU communication protocol&lt;BR&gt;Startup, control, and protection are integrated into the CPU, and communication between the field layer and control layer uses bus technology&lt;BR&gt;&lt;BR&gt;The CD4 series motor control protector has overload protection, underload protection, locked rotor protection, unbalanced protection, phase failure protection, thermistor PTC protection, hourly starting frequency protection, external fault protection, ground fault protection or residual current protection, low voltage protection, overvoltage protection, underpower protection, and reverse sequence protection&lt;BR&gt;The tripping levels of overload protection are divided into 10A, 10, 15, 20, 25, and 30, which can greatly optimize the use of electric motors&lt;BR&gt;Built in CPU monitors the real-time status of the motor operation&lt;BR&gt;Equipped with nine switch inputs and four relay outputs&lt;BR&gt;Control protector complies with GB 14048.4 standard&lt;BR&gt;The control protector has obtained the national mandatory product certification &quot;CCC&quot; mark&lt;BR&gt;&lt;BR&gt;Main technical parameters of CD4 series motor control protector&lt;BR&gt;Table 1 Basic Parameters of Control Protector&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=229 colSpan=2&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;CD4-100R1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;CD4-100R2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;CD4-100R3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;CD4-200S1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;CD4-450T1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=229 colSpan=2&gt;
&lt;P align=center&gt;Rated working voltage Ue/V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;AC50Hz/ 400¡¢690&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=229 colSpan=2&gt;
&lt;P align=center&gt;Rated insulation voltage U&lt;SUB&gt;i&lt;/SUB&gt;/V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=229 colSpan=2&gt;
&lt;P&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;/kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=229 colSpan=2&gt;
&lt;P align=center&gt;Release level&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;10A¡¢10¡¢15¡¢20¡¢25¡¢30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;overload protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Set current Ir1/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;1.25~6.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;6.3~25&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;25~100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;50~200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;160~450&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t1/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;Delay t1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;Overload protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action current Ir2/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P&gt;(20%~80%) Ir1+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t2/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;1~30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;locked-rotor protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action current Ir3/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;(300%~800%) Ir1+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t3/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.2~13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;Current imbalance protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Imbalance degree ¦Å I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;20%~80%+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t5/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;phase failure protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Imbalance degree ¦Å I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;90%~100%+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t6/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;zero point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;PTC overheat protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Setting value k ¦¸&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;3+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t10/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=124&gt;
&lt;P&gt;Hourly startup frequency protection (alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Number of actions (times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;1~30+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;Ground fault protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action current Ir4/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;(40%~80%) Ir1+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t4/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.1, 0.2, 0.3, 0.4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=124&gt;
&lt;P align=center&gt;Residual current protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P&gt;Action current I ¡÷ n/A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=252 colSpan=3&gt;
&lt;P align=center&gt;0.3/0.5/1/3/10&amp;nbsp; +OFF&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=206 colSpan=2&gt;
&lt;P align=center&gt;0.5/1/3/10 /30 +OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=105&gt;
&lt;P align=center&gt;Action time/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;Non delayed&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;delay&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;low voltage protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Setting value V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;(65%¡¢75%¡¢85%)Ue+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t7/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.5~20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;overvoltage protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Setting value V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;(105%¡¢110%¡¢115%)Ue+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t8/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.1~20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=124&gt;
&lt;P align=center&gt;Under power protection&lt;BR&gt;(Alarm or trip)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Setting value kW&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P&gt;(20%~95%)Pe+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Action time t9/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.5~25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=124&gt;
&lt;P align=center&gt;Low voltage restart&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Restarting voltage setting value V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;(75%¡¢85%¡¢95%)Ue+OFF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Immediately restart and lose power time t11/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.1~0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;Delay restart delay time t12/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=458 colSpan=5&gt;
&lt;P align=center&gt;0.5~20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Table 2 Code for Setting Current Range&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Current specification (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;Code for setting current range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;Setting current range (A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=104&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;R1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;1.25-6.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;R2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;6.3-25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;R3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;25-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;S1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;50-200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;four hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=130&gt;
&lt;P align=center&gt;T1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=181&gt;
&lt;P align=center&gt;160-450&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JD-5B motor comprehensive protector </title>
           <link>http://www.91way.com/info_en/26066.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:48:06</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201411/20141126190932852.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 581px; HEIGHT: 537px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JD-5B motor comprehensive protector&quot; src=&quot;/upload2014/201411/20141126190932852.jpg&quot; width=581 height=537&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JD-5B motor comprehensive protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JD-5 motor comprehensive protector </title>
           <link>http://www.91way.com/info_en/26065.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JD-5 motor comprehensive protector&lt;BR&gt;&lt;BR&gt;Working power supply: AC220V 380V 50Hz&lt;BR&gt;Rated current or rated power: Type A: 0.5-5A; Type C: 63-150A; Type B: 2-80A; Type D: 100-250A&lt;BR&gt;Protection function: 1. Phase failure protection function 2. Overcurrent protection function&lt;BR&gt;Display mode: LED indicator&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201411/20141126190721332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 581px; HEIGHT: 537px&quot; border=0 hspace=0 alt=&quot;JD-5 motor comprehensive protector wiring diagram and installation dimensions&quot; src=&quot;/upload2014/201411/20141126190721332.jpg&quot; width=581 height=537&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]QZ20 series comprehensive protection starter </title>
           <link>http://www.91way.com/info_en/25155.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:49</pubDate>
           <comments></comments>
           <description>The QZ20 series comprehensive protection starter is a new generation starter designed in accordance with the requirements of the national standard GB14048.4 and the equivalent use of IEC947-4-1&lt;BR&gt;&lt;BR&gt;The QZ20 series comprehensive protection starter is suitable for infrequent direct starting and stopping of three-phase asynchronous motors with AC 50Hz, rated voltage 380V, and power up to 10KW. It has free tripping and dedicated overload tripping, which can effectively protect the motor from overload and phase failure. It is widely used as a motor protection switch for submersible electric pumps, threshers, cotton spinning machinery, cement mines, and general machinery.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]BHQ-Y type motor phase failure protector </title>
           <link>http://www.91way.com/info_en/23509.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:41</pubDate>
           <comments></comments>
           <description>The BHQ type motor phase failure protector is a new product that was upgraded and replaced with protection devices in the 1990s. It has the advantages of high sensitivity, small size, easy use, and reliable operation. This product, when used in conjunction with a contactor, is unparalleled by other motor protection devices and is the most ideal motor protection device.&lt;BR&gt;&lt;BR&gt;The BHQ-Y type phase failure protector works using the principle of electromagnetic magnetic response and current parameter balance control method. It can quickly cut off the power supply in case of phase failure of three-phase motors (such as power supply phase loss, fuse melting, etc.) within the rated current range, achieving the purpose of protecting the motor. This product has a wide range of applications, a simple structure, and stable performance. It has the advantages of shock resistance, temperature resistance, and moisture resistance. The rated minimum working current of the standard does not require maintenance for long-term use. The protector must work normally under the load and be in a phase loss state when not connected to the load. After long-term use, it has been proven that the use of protectors and the reduction of motor damage ensure normal production and have high practical value.&lt;BR&gt;&lt;BR&gt;Technical Features&lt;BR&gt;1. Environmental temperature: -20 ¡æ --+50 ¡æ&lt;BR&gt;2. Voltage: Three phase 380V, 50Hz&lt;BR&gt;3. Working time: less than 1 second&lt;BR&gt;4. Work location: Any&lt;BR&gt;5. Contact current: not less than 1A&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JDB-KM+ series electric motor intelligent protection monitoring system </title>
           <link>http://www.91way.com/info_en/22016.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:32</pubDate>
           <comments></comments>
           <description>JDB-KM+series intelligent protection and monitoring system for electric motors&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]RMD2 series motor protector </title>
           <link>http://www.91way.com/info_en/21826.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:24</pubDate>
           <comments></comments>
           <description>Characteristics of RMD2 series motor protector&lt;BR&gt;&lt;BR&gt;Can be equipped with a communication interface&lt;BR&gt;Integrating measurement, protection, monitoring, operation, and control&lt;BR&gt;Modular design structure, small size, compact structure&lt;BR&gt;Fully equipped with intelligent protection functions&lt;BR&gt;&lt;BR&gt;specification&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=183&gt;
&lt;P align=center&gt;Product Model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;Rated working current of electric motor (A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=183&gt;
&lt;P align=center&gt;RMD2-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;045-2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=183&gt;
&lt;P align=center&gt;RMD2-5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;1-5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=183&gt;
&lt;P align=center&gt;RMD2-25&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=190&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMD2 series motor protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JVRD Voltage Phase Sequence Protector </title>
           <link>http://www.91way.com/info_en/20440.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Model name:&lt;BR&gt;1. Full function protection series&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201208/20120828154938253.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 591px; HEIGHT: 156px&quot; border=0 hspace=0 alt=&quot;Model Description of JVRD Voltage Phase Sequence Protector&quot; src=&quot;/upload2012/201208/20120828154938253.jpg&quot; width=591 height=156&gt;&lt;/A&gt;&lt;BR&gt;2. No overvoltage or undervoltage protection series&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201208/20120828154946219.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 626px; HEIGHT: 112px&quot; border=0 hspace=0 alt=&quot;Selection Instructions for JVRD Voltage Phase Sequence Protector&quot; src=&quot;/upload2012/201208/20120828154946219.jpg&quot; width=626 height=112&gt;&lt;/A&gt;&lt;BR&gt;Functional features:&lt;BR&gt;Completely replaceable with Schneider RM4T structure&lt;BR&gt;Compact appearance, rail installation&lt;BR&gt;Phase loss protection ¡ñ Reverse phase protection ¡ñ Undervoltage protection ¡ñ Overvoltage protection ¡ñ Three phase voltage imbalance&lt;BR&gt;Contact form: Two open and two closed&lt;BR&gt;&lt;BR&gt;Application scenarios:&lt;BR&gt;The product is widely used in industries such as central air conditioning, cranes, refrigeration equipment, compressors, distribution boxes, elevators, various (passenger and cargo) elevators, cranes, cranes, machine tools, controller equipment, etc&lt;BR&gt;&lt;BR&gt;Voltage Range Selection Table:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828155037197.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 630px; HEIGHT: 324px&quot; border=0 hspace=0 alt=&quot;Voltage range of JVRD voltage phase sequence protector&quot; src=&quot;/upload2012/201208/20120828155037197.jpg&quot; width=630 height=324&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201208/20120828155046858.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 622px; HEIGHT: 327px&quot; border=0 hspace=0 alt=&quot;Voltage setting of JVRD voltage phase sequence protector&quot; src=&quot;/upload2012/201208/20120828155046858.jpg&quot; width=622 height=327&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Main technical parameters:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828155118515.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 639px; HEIGHT: 224px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JVRD voltage phase sequence protector&quot; src=&quot;/upload2012/201208/20120828155118515.jpg&quot; width=639 height=224&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Structural characteristics:&lt;BR&gt;1. The base of the protector adopts a guide rail type and is equipped with two M4 screw hole structures, which can be directly installed independently or installed on HT35 guide rails&lt;BR&gt;If direct installation is used, the accessories on both sides of the bottom of the product need to be forcefully pushed out.&lt;BR&gt;2. Indicator lights: Five indicator lights are used to indicate: normal, phase loss (voltage three-phase imbalance), reverse phase, overvoltage, undervoltage.&lt;BR&gt;3. Dimensions: 79mm &#215; 23mm &#215; 79mm&lt;BR&gt;&lt;BR&gt;Outline drawing and typical wiring diagram:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828155156991.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 530px; HEIGHT: 506px&quot; border=0 hspace=0 alt=&quot;Installation dimensions and wiring diagram of JVRD voltage phase sequence protector&quot; src=&quot;/upload2012/201208/20120828155156991.jpg&quot; width=530 height=506&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]SXB Phase sequence protector </title>
           <link>http://www.91way.com/info_en/20439.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:47:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;SXB series phase sequence protector&lt;BR&gt;1 Overview&lt;BR&gt;The SXB series phase sequence protector is mainly used for various fault detection of AC 50/60Hz, rated voltage below 460V, industrial three-phase 220V, 380V, 440V, 460V and other voltage levels. It provides relay protection for three-phase input power supply phase loss, reverse phase (phase sequence), etc. The product is widely used in air compressors, motors, distribution boxes, water pumps, oil pumps, central air conditioning units, electric control boxes, distribution cabinets, cranes, etc., such as central air conditioning compressor protection, power monitoring of various elevators, anti phase loss and reverse phase protection of water pumps and oil pumps, etc. It is an indispensable protection product for maintaining normal working voltage of industrial equipment during operation.&lt;BR&gt;&lt;BR&gt;This product complies with the GB14085.5-2001 eqv IEC60947-1:1999 standard. Warning! This product is generally used for sampling the power side of three-phase power supplies and should not be installed on the output side of variable frequency power supplies!&lt;BR&gt;&lt;BR&gt;2 Structural Features&lt;BR&gt;1) Installation method: The protector base adopts a guide rail type, with two M4 screw hole structures inside, and can be installed independently or on HT35 guide rails.&lt;BR&gt;2) Indicator lights: Three indicator lights are used to indicate: normal, phase loss (voltage three-phase imbalance), and reverse phase.&lt;BR&gt;3) Dimensions: 79mm &#215; 23mm &#215; 79mm.&lt;BR&gt;4 Protection Characteristics&lt;BR&gt;1) Phase loss protection: Refers to a delay of 2 seconds in the event of a phase failure in either the operating or non operating state of the protected circuit.&lt;BR&gt;2) Reverse phase protection: a protective measure to prevent the wrong phase sequence connection of L1, L2, and L3 three-phase AC, with a delay of 2 seconds.&lt;BR&gt;&lt;BR&gt;5 Main Technical Data&lt;BR&gt;1) Main circuit:&lt;BR&gt;1) Rated voltage: 220VAC, 380VAC, 440VAC, 460VAC.&lt;BR&gt;2) The connecting wire of the main circuit: insulated copper wire with a load area of 1.0-2.5mm. If a single strand of copper wire can be directly inserted into the terminal post; If a flexible wire is used, a pin type connector must be added to the wire to ensure reliable connection.&lt;BR&gt;2) Auxiliary circuit:&lt;BR&gt;1) It has two normally open and two normally closed contacts that are electrically inseparable.&lt;BR&gt;2) Usage category: AC15, DC13&lt;BR&gt;3) Contact capacity: 250VAC 6A, 30VDC 3A&lt;BR&gt;4) Agreed heating current: 6A&lt;BR&gt;&lt;BR&gt;6 Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828153301931.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 408px; HEIGHT: 207px&quot; border=0 hspace=0 alt=&quot;External dimensions of SXB phase sequence protector&quot; src=&quot;/upload2012/201208/20120828153301931.jpg&quot; width=408 height=207&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JVRD6-E Phase failure and phase mismatch protector </title>
           <link>http://www.91way.com/info_en/20438.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:58</pubDate>
           <comments></comments>
           <description>JVRD6-E Phase Failure and Misalignment Protector (referred to as Protection Board), which is designed to provide reliable protection against phase failure and misalignment during the operation of electric hoists and cranes Specially designed for the internal matching of control boxes for electric hoists and cranes, with small size, simple wiring, easy installation, and improved safety and reliability, it is an indispensable protective product in industrial equipment operation.&lt;BR&gt;&lt;BR&gt;model naming&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201208/20120828152949801.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 373px; HEIGHT: 101px&quot; border=0 hspace=0 alt=&quot;Model Description of JVRD6-E Phase Failure and Misalignment Protector&quot; src=&quot;/upload2012/201208/20120828152949801.jpg&quot; width=373 height=101&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]RD6-E Phase failure and phase mismatch protector </title>
           <link>http://www.91way.com/info_en/20432.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:49</pubDate>
           <comments></comments>
           <description>I. Overview&lt;BR&gt;RD6-E phase failure and phase mismatch protector (referred to as protection board), which is designed to provide reliable protection for phase failure and phase mismatch that occur during the operation of electric hoists and cranes.&lt;BR&gt;Specially designed for the internal matching of control boxes for electric hoists and cranes, with small size, simple wiring, easy installation, and improved safety and reliability, it is an indispensable protective product in industrial equipment operation.&lt;BR&gt;&lt;BR&gt;2¡¢ Main technical parameters and functional characteristics&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Features&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Phase discontinuity and phase mismatch&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;200-500VAC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;50/60HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Usage category&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;AC-15,DC-13&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;contact form &lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;1. Normally open&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Contact capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;250VAC/5A,30VDC/3A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;action delay&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;1 second action for phase interruption and misalignment&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;3¡¢ Host interface and interface&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828150600396.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 645px; HEIGHT: 665px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of RD6-E phase failure and phase mismatch protectors&quot; src=&quot;/upload2012/201208/20120828150600396.jpg&quot; width=645 height=665&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;4¡¢ Typical wiring diagram&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120828150612974.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 641px; HEIGHT: 631px&quot; border=0 hspace=0 alt=&quot;RD6-E Phase Failure and Phase Error Protector Wiring Diagram&quot; src=&quot;/upload2012/201208/20120828150612974.jpg&quot; width=641 height=631&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]UL-E20 series motor protector </title>
           <link>http://www.91way.com/info_en/20377.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:41</pubDate>
           <comments></comments>
           <description>The UL-E20 series motor protector has symmetrical faults (such as overload, overcurrent, locked rotor) and asymmetrical faults (such as various phase breaks, current imbalances, phase to phase short circuits, turn to turn short circuits, etc.) as well as phase sequence, overvoltage, and undervoltage protection.&lt;BR&gt;&lt;BR&gt;This motor protector has the characteristics of simple structure, complete functions, high precision, reliable action, convenient use, and small size. It is an ideal replacement product for thermal relays, especially suitable for harsh working environments and poor power grid quality.&lt;BR&gt;&lt;BR&gt;Specifications and technical parameters&lt;BR&gt;UL-E20 series motor protector model naming convention&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201208/20120825194758344.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 279px; HEIGHT: 153px&quot; border=0 hspace=0 alt=&quot;UL-E20 series motor protector model description&quot; src=&quot;/upload2012/201208/20120825194758344.jpg&quot; width=279 height=153&gt;&lt;/A&gt;&lt;BR&gt;*The basic function does not have phase sequence protection and overvoltage/undervoltage protection.&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;specification&lt;BR&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=46&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=55&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=112&gt;
&lt;DIV align=center&gt;three hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;technical parameters&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Current adjustment range (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=46&gt;
&lt;DIV align=center&gt;1-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;4-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;16-80&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;64-320&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Applicable motor power (kw) (380v)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=46&gt;
&lt;DIV align=center&gt;0.5-2.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;2-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;8-40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;32-160&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Starting delay time (s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;2-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;4-40&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Installation method&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Card rail&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;Card rail&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;44(W)X63(D)X86(H)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;88(W)X60(D)X115(H)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Main circuit wiring method&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Pressure line type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;Piercing style (20X32)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Output control terminal at COS &amp;Oslash;=0.4AC380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;P align=center&gt;Normally open (97, 98) 2A&lt;BR&gt;Normally closed (97, 98) 2A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;Normally open (97, 98) 3A&lt;BR&gt;Normally closed (97, 98) 3A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Power consumption&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Not exceeding 0.5W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;Not exceeding 1W&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=154&gt;
&lt;DIV align=center&gt;Reset method&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94 colSpan=2&gt;
&lt;DIV align=center&gt;Power off reset&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=171 colSpan=2&gt;
&lt;DIV align=center&gt;Power off reset or manual reset&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;performance metrics&lt;BR&gt;1. Protection functions: phase failure, overload, overcurrent, locked rotor, three-phase current imbalance, phase sequence, overvoltage and undervoltage.&lt;BR&gt;2. Overcurrent action characteristics: trip according to inverse time limit.&lt;BR&gt;3. Current setting error: ¡Ü&#177; 5%&lt;BR&gt;4. Applicable frequency: 45~65Hz&lt;BR&gt;5. Phase interruption action time: 2s&lt;BR&gt;6. Phase sequence protection action time: 0.1s&lt;BR&gt;7. Overvoltage and undervoltage protection: 380V -20% ¡Ü U ¡Ü 380V+10%&lt;BR&gt;8. Unbalance protection: When the imbalance degree is ¡Ý 50% &#177; 10, the action time is 2 seconds; the three-phase current imbalance degree=[(maximum current value - minimum current value)/maximum current value] &#215; 100%&lt;BR&gt;9. Reset time: 20 minutes&lt;BR&gt;10. Environmental temperature: -40 ¡æ~+60 ¡æ&lt;BR&gt;11. Environmental humidity: ¡Ü 90% (25 ¡æ)&lt;BR&gt;12. Working power supply voltage: AC380V three-phase&lt;BR&gt;&lt;BR&gt;UL-E20 series motor protector external dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120825194811132.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 324px&quot; border=0 hspace=0 alt=&quot;UL-E20 series motor protector appearance and installation dimensions&quot; src=&quot;/upload2012/201208/20120825194811132.jpg&quot; width=540 height=324&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]WDB Electric motor intelligent protector </title>
           <link>http://www.91way.com/info_en/20376.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:32</pubDate>
           <comments></comments>
           <description>The WDB series has advanced fieldbus interfaces and is a motor protection and control device developed based on microprocessor technology. The protection and control functions of the motor are executed by the microprocessor, which completes the statistics of the number of motor operations, self diagnosis, and communication with the upper computer. WDB provides comprehensive protection for motors, avoiding production accidents caused by motor overload, overheating, locked rotor, undervoltage, light load, phase failure, three-phase imbalance, grounding and other possible faults, and maximizing the effectiveness and safety of equipment operation. WDB adopts RS485 communication interface design to ensure fast and reliable communication with the upper computer, PLC, DCS, and can quickly respond to real-time query requirements of the upper host and perform corresponding operations. Easy to use, safe and reliable.&lt;BR&gt;&lt;BR&gt;protection function&lt;BR&gt;Overcurrent protection, phase failure protection, three-phase unbalance protection, locked rotor protection, undervoltage protection, leakage protection, short circuit protection.&lt;BR&gt;&lt;BR&gt;Display monitoring&lt;BR&gt;Operating status, three-phase current, line voltage, leakage current, and fault information display&lt;BR&gt;&lt;BR&gt;Fieldbus function&lt;BR&gt;WDB has RS-485 remote communication interface, supports MODBUS-RTU, bus protocol, and is convenient for forming network systems with PLC, DCS, and backend machines. Real time control, monitoring of operational status parameters, and historical data queries of on-site equipment are carried out through the backend machine. WDB's monitoring and recording of motor operation status and fault causes greatly facilitates the development of motor maintenance plans and reduces equipment maintenance costs.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]WJB+1E Electric motor intelligent protector </title>
           <link>http://www.91way.com/info_en/20375.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:24</pubDate>
           <comments></comments>
           <description>WJB+1E motor intelligent protector&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]ULD-E2 series passive motor protector </title>
           <link>http://www.91way.com/info_en/20374.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:16</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120825115547726.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 607px&quot; border=0 hspace=0 alt=&quot;Technical parameters, external dimensions, and wiring diagram of ULD-E2 series passive motor protector&quot; src=&quot;/upload2012/201208/20120825115547726.jpg&quot; width=650 height=607&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ULD-E2 series passive motor protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]UL-E2 Passive motor protector </title>
           <link>http://www.91way.com/info_en/20373.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:46:07</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120825115214661.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 607px&quot; border=0 hspace=0 alt=&quot;Technical parameters, installation dimensions, and wiring diagram of UL-E2 passive motor protector&quot; src=&quot;/upload2012/201208/20120825115214661.jpg&quot; width=650 height=607&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201208/20120825115347814.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 273px; HEIGHT: 236px&quot; border=0 hspace=0 alt=&quot;Outline drawing of UL-E2 passive motor protector&quot; src=&quot;/upload2012/201208/20120825115347814.jpg&quot; width=273 height=236&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;UL-E2 Passive Motor Protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]HSD1 series electronic motor protector </title>
           <link>http://www.91way.com/info_en/16104.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:58</pubDate>
           <comments></comments>
           <description>Product Details&lt;BR&gt;&lt;BR&gt;The HSD1 series electronic motor protector is suitable for use in the circuit of a single AC asynchronous motor with an AC frequency of 50Hz, rated voltage up to 380V, and rated current of 0.5A~500A. It can be combined with HSC1 series AC contactors (HSC1-9~25 can be plugged in) or other types of AC contactors to protect against overload, phase failure, three-phase imbalance and other faults that occur in the motor circuit during operation.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JDB-LQ+F Electric Motor Intelligent Monitor </title>
           <link>http://www.91way.com/info_en/5204.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:50</pubDate>
           <comments></comments>
           <description>Product Overview&lt;BR&gt;&lt;BR&gt;JDB-LQ+is a motor protection and control device developed based on microprocessor technology with advanced fieldbus interfaces. The protection and control functions of the motor are executed by the microprocessor, which completes the statistics of the number of motor operations, self diagnosis, and communication with the upper computer. JDB-LQ+provides comprehensive protection for motors, avoiding production accidents caused by possible faults such as motor overload, overheating, locked rotor, undervoltage, light load, phase failure, three-phase imbalance, grounding, etc., and maximizing the effectiveness and safety of equipment operation. JDB-LQ+adopts a 4-20mA and RS485 communication interface design, ensuring fast and reliable communication with the upper computer, PLC, and DCS. At the same time, it can quickly respond to real-time query requirements of the upper host and perform corresponding operations. Easy to use, safe and reliable.&lt;BR&gt;protection function&lt;BR&gt;Thermal overload protection, explosion-proof motor Eexe thermal overload protection, phase failure protection, three-phase unbalance protection, locked rotor protection, undervoltage protection, ground fault protection, light load protection, and no-load protection.&lt;BR&gt;&lt;BR&gt;control function&lt;BR&gt;Direct starting, star delta starting, autotransformer step-down starting, multi-party starting control.&lt;BR&gt;&lt;BR&gt;Display monitoring&lt;BR&gt;Operating status, three-phase current, line voltage, leakage current, and fault information display&lt;BR&gt;Fieldbus function&lt;BR&gt;JDB-LQ has an RS-485 remote communication interface and supports MODBUS-RTU and PROFIBUS-DP bus protocols, making it easy to form network systems with PLCs, DCS, and backend machines. Real time control, monitoring of operational status parameters, and historical data queries of on-site equipment are carried out through the backend machine. JDB-LQ's monitoring and recording of motor operation status and fault causes greatly facilitates the development of motor maintenance plans and reduces equipment maintenance costs.&lt;BR&gt;&lt;BR&gt;JDB-LQ+F Electric Motor Intelligent Monitor&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Motor protector]WJB+F Motor protection monitoring device </title>
           <link>http://www.91way.com/info_en/5203.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:41</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Overview&lt;BR&gt;WJB+is a motor protection and control device developed based on microprocessor technology with advanced fieldbus interfaces. The protection and control functions of the motor are executed by the microprocessor, which completes the statistics of the number of motor operations, self diagnosis, and communication with the upper computer. WJB+provides complete protection for motors, avoiding production accidents caused by motor overload, overheating, locked rotor, undervoltage, light load, phase failure, three-phase imbalance, grounding and other possible faults, and maximizing the effectiveness and safety of equipment operation. WJB+adopts RS485 communication interface design, ensuring fast and reliable communication with the upper computer, PLC, DCS, and can quickly respond to real-time query requirements of the upper host and perform corresponding operations. Easy to use, safe and reliable.&lt;BR&gt;protection function&lt;BR&gt;Thermal overload protection, explosion-proof motor Eexe thermal overload protection, phase failure protection, three-phase unbalance protection, locked rotor protection, undervoltage protection, ground fault protection, light load protection, and no-load protection.&lt;BR&gt;&lt;BR&gt;control function&lt;BR&gt;Direct starting, star delta starting, autotransformer step-down starting, multi-party starting control.&lt;BR&gt;&lt;BR&gt;Display monitoring&lt;BR&gt;Operating status, three-phase current, line voltage, leakage current, and fault information display&lt;BR&gt;&lt;BR&gt;Fieldbus function&lt;BR&gt;WJB+has RS-485 remote communication interface, supports MODBUS-RTU, bus protocol, and is convenient for forming network systems with PLC, DCS, and backend machines. Real time control, monitoring of operational status parameters, and historical data queries of on-site equipment are carried out through the backend machine. WJB+greatly facilitates the development of motor maintenance plans and reduces equipment maintenance costs by monitoring and recording the operating status and causes of faults of motors.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094710223898.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 338px; HEIGHT: 282px&quot; border=0 hspace=0 alt=&quot;WJB+F motor protection monitoring device characteristic curve 1&quot; src=&quot;/uploadfiles/200904/20094710223898.jpg&quot; width=338 height=282&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200947102224389.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 462px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;WJB+F motor protection monitoring device characteristic curve 2&quot; src=&quot;/uploadfiles/200904/200947102224389.jpg&quot; width=462 height=260&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094710254734.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Technical Description of WJB+F Motor Protection Monitoring Device&quot; src=&quot;/uploadfiles/200904/20094710254734.jpg&quot; width=650 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200947102528478.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of WJB+F motor protection monitoring device&quot; src=&quot;/uploadfiles/200904/200947102528478.jpg&quot; width=650 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;WJB+F motor protection monitoring device&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]JD-6 type motor comprehensive protector </title>
           <link>http://www.91way.com/info_en/4087.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:32</pubDate>
           <comments></comments>
           <description>Model parameters of JD-6 motor comprehensive protector&lt;BR&gt;&lt;BR&gt;Current specification: 63-400A&lt;BR&gt;&lt;/TD&gt;Dimensions: 64 * 157 * 126&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Wire hole diameter (mm)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡é26&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Protection time (s)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;number of contacts&lt;/TD&gt;
&lt;TD vAlign=top&gt;
&lt;DIV align=center&gt;1 Conversion&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact capacity&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact electrical lifespan&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10*10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ambient temperature&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-5~+40&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working voltage&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC:220V¡¢380V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Installation method&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Installation type&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Installation size wiring diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201411/20141126191118314.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 581px; HEIGHT: 537px&quot; border=0 hspace=0 alt=&quot;Wiring diagram and installation dimensions of JD-6 type motor comprehensive protector&quot; src=&quot;/upload2014/201411/20141126191118314.jpg&quot; width=581 height=537&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]HG-D type intelligent motor protector </title>
           <link>http://www.91way.com/info_en/4056.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview&lt;BR&gt;&lt;BR&gt;The HG-D intelligent motor protector series is suitable for frequent starting and stopping of three-phase squirrel cage asynchronous motors with AC 50 Hz or 60 Hz, rated voltage of 500 volts or less, and capacity of 20 kilowatts or less. Thermal circuit breakers provide protection against phase failure and overcurrent in electric motors. This product is widely used in various air pumps and is the preferred choice for controlling them.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/200873153344315.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 341px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of HG-D intelligent motor protector&quot; src=&quot;/uploadfiles/200807/200873153344315.jpg&quot; width=550 height=341&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;BR&gt;Figure 10 Appearance and installation dimensions of HG-D intelligent electronic electric protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]QZ610 series motor protection starter </title>
           <link>http://www.91way.com/info_en/4053.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview&lt;BR&gt;The QZ610 series motor protection starter is suitable for infrequent direct starting and stopping of three-phase asynchronous motors with AC 50 Hz, rated voltage 380 volts, and power up to 4 to 17 kilowatts. Equipped with thermal relay, instantaneous action device for phase failure, and shunt release, it can effectively protect the motor from overload and phase failure. It is widely used in submersible electric pumps, threshers, textile machinery, cement mining machinery, and general machinery motor protection switches.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200807/200873145119900.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 299px&quot; border=0 hspace=0 alt=&quot;Technical parameters of QZ610 series motor protection starter&quot; src=&quot;/uploadfiles/200807/200873145119900.jpg&quot; width=550 height=299&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;QZ610 series motor protection starter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Motor protector]QJZ3 Motor comprehensive protection starter </title>
           <link>http://www.91way.com/info_en/330.html</link>
           <author></author>
           <guid></guid>
           <category>Motor protector</category>
           <pubDate>2026-6-18 14:45:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The QJZ3 motor comprehensive protection starter (hereinafter referred to as the starter) is a new type of motor starter suitable for infrequent voltage reduction starting and stopping of three-phase squirrel cage induction motors with AC 50Hz voltage of 380V and power of 10-75kw. The starter is equipped with a reliable comprehensive protector, which provides reliable protection against phase failure, overload, and voltage loss of the motor.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/200882403539343.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 592px; HEIGHT: 611px&quot; border=0 hspace=0 alt=&quot;Technical parameters of QJZ3 motor comprehensive protection starter&quot; src=&quot;/uploadfiles/200808/200882403539343.gif&quot; width=592 height=611&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/200882403549882.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 595px; HEIGHT: 137px&quot; border=0 hspace=0 alt=&quot;QJZ3 motor comprehensive protection starter model description&quot; src=&quot;/uploadfiles/200808/200882403549882.gif&quot; width=595 height=137&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;QJZ3 motor comprehensive protection starter&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>