Overview:
The KYC09 series liquid level sensor adopts the famous American NovaSensor company's high-precision, high stability, isolated solid-state sensor, which is assembled through precise temperature compensation and fully welded structure. This product comes in two structural types: integrated and split, and has three types of medium measurement: ordinary, armored, and anti-corrosion. Armored and anti-corrosion products can resist the erosion of various corrosive liquids. This product can be widely used in various industries for liquid level detection and control of various liquids.
Features:
High precision, high stability, high reliability
Small size, beautiful appearance, high cost-effectiveness
From 0~0.5m to 0~170m
316L stainless steel isolation diaphragm
Cable type, armored type, anti-corrosion type
Application:
Industrial field liquid level measurement and control
Measurement and Control of Water Level in Dajiang Dam
Ships and Navigation Systems
Water supply and sewage treatment
Hydrological measurement and water conservancy construction
KYC09 liquid level sensor indicators and parameters:
| measuring medium |
Various liquids (please choose different structural types according to the type of medium) |
measurement range
|
From 0~0.5m to 0~170m (see selection table) |
| Overload pressure |
2 times the maximum range |
| Nonlinear |
± 0.25% (0.25 level), ± 0.5% (0.5 level) |
| Repetitive delay |
± 0.15% (0.25 level), ± 0.25% (0.5 level) |
| power supply |
0.5~2mA (constant current power supply); Standard current 1mADC ± 1% 9-36VDC (constant voltage power supply); Standard voltage 12VDC ± 1% |
| Zero point output |
-2mV~+2mV |
| Full range output |
15~230mV (depending on the actual range selected by the user) |
| compensation temperature |
0~70℃ |
| Operating Temperature |
-20~85℃ |
| temperature effect |
± 1.5% FS (0.25 level), ± 3.0% FS (0.5 level) (Zero point and sensitivity temperature influence, relative to 25 ℃, compensation temperature: 0~70 ℃) |
| Drift at midnight |
± 0.2% FS/8 hours |
| Stability |
± 0.25% FS/1 year |
| Membrane material |
316L stainless steel (ordinary and armored types); Ceramic membrane (anti-corrosion type) |
| Probe material |
1Cr18Ni9Ti (ordinary and armored types); Polytetrafluoroethylene (anti-corrosion type) |
| leader line |
Double layer wear-resistant ventilation cable (ordinary type); Armored tube (armored type); Polytetrafluoroethylene tube (anti -) |