The SLB70 RF admittance level switch is a point-to-point level switch manufactured based on the principle of RF admittance measurement, and is a replacement product for capacitive level switches. Even under extremely harsh on-site conditions, it can work reliably without being affected by material hanging, pressure, material density, humidity, and changes in material chemical properties.
Strong usability: widely used in various occasions, including fly ash, particles, powders, liquids, viscous, conductive, and non-conductive materials;
Anti adhesion: The unique circuit design allows the measurement circuit to ignore the accumulated materials on the probe and automatically correct them;
Detached probe: The probe and controller can be separated without cable connection, making installation and removal easy and not affecting on-site work;
Powerful function: Large output contact capacity and status indicator light to display working status, with a delay of 0-30 seconds to eliminate the impact of material fluctuations;
Technical parameters
Power supply: 230 ± 25VAC, 50/60HZ, maximum 5W, 24VDC (optional)
Output:
SL-CB100: DPDT relay output (double pole double throw)
SL-CB400: 2 DPDTs
Contact capacity: 230VAC, 5A, non inductive, 3A inductive
Environmental temperature: -40~70 ℃
Medium temperature:
SL-CB100: -185~800 ℃, (inquire with the company for temperatures above 800 ℃)
SL-CB400: -185~260 ℃, (inquire with the company for temperatures above 260 ℃)
Response time: Approximately 0.2 seconds (standard), adjustable from 0 to 90 seconds (optional)
Repeatability:
Conductive medium: 1/16 inch (1.6mm)
Insulation medium: 2 inches (50.8mm)
Spark protection: (for sensors)
10A (standard)
100A (additional protective circuit)
Shell material: Explosion proof cast aluminum or ABS
Protection level: IP66
Explosion proof area:
Explosion proof cast aluminum shell FM certification
All groups of cables and sensing elements in Zone 1 and Zone 2 are intrinsically safe and explosion-proof
The circuit units inside the explosion-proof enclosure are explosion-proof in all groups of Zone 1 and Zone 2
CENELEC certification
Ex Ⅱ C T3 (original imported table for explosion-proof places)
Installation of sensing components:
NPT thread (standard)
Flange installation (optional)
Cable interface: 1/2 NPT
Cable:
The cable between the split electronic unit and the sensor is provided by the manufacturer, with a standard length of 3 meters
Output insulation: signal line to sensor greater than 1000V
Installation Diagram