The UDZ-II series liquid level measuring cylinder and M16 × 1.5 × 87, M16 × 1.5 × 115 electrodes are matched with a dual color analog water level indicator to form a complete set of water level measuring devices. The electrode mounting seat of the measuring cylinder can be designed to be inclined upwards or downwards according to user requirements (the inclined insertion has some advantages: when water and steam reach the extreme point, it is not easy to hang water, steam, liquid, and is prone to evaporation and sliding, which has an effect on preventing false water level display of the instrument).
Measurement cylinder model and specifications
1. Output contact capacity of the relay: upper limit, upper limit normally open and normally closed 220V 3A.
Lower limit, lower limit normally open and normally closed 220V 3A.
2. Length from electrical contact to instrument lead: ≤ 200m.
3. Usage environment: Temperature: -10 ℃~50 ℃, Temperature: ≤ 85%
| Item No. |
Measuring cylinder number |
pressure resistance |
temperature |
Center of vapor-liquid connecting pipe |
| one |
01 |
6.3MPa |
250℃ |
User-defined |
| two |
02 |
16.0MPa |
350℃ |
User-defined |
| three |
03 |
22MPa |
380℃ |
User-defined |