8962C1 frequency converter dedicated measuring instrument
Instruments made for testing equipment such as variable frequency power supplies and variable frequency motors.
The tester adopts a new high-speed, pipeline structure core with a computing speed of up to 100MIPS, and is equipped with a speed of
200k high-speed A/D for sampling.
The design widely adopts highly integrated chips, making the internal structure of the entire instrument compact and simple. At the same time, it has increased the overall height of the machine
Reliability and accuracy.
320X240 large screen LCD display
RS232/485 communication interface
The 8962C1 frequency converter dedicated measuring instrument is equipped with 500Hz and 5kHz filters. When measuring frequency conversion motors or poor voltage signals, it can choose to filter the voltage and current signals to remove the influence of high-order harmonics.
The waveform output by a frequency converter is generally modulated. If voltage filtering is not performed, the voltage waveform will be very chaotic, with large and unstable values. After using filtering, the waveform will appear smoother and the data will be stable.
The voltage waveform output by the unfiltered frequency converter is shown in the following figure:
The voltage waveform output by the filtered frequency converter is shown in the following figure:
Test legend for frequency converter output
| Test function | Test parameter description |
| Steady state measurement | Three phase voltage (5-600V), three-phase current (0.03-5.0), active power, reactive power, apparent power Power factor, frequency (5-800Hz), electrical energy and cumulative electrical energy time, voltage imbalance |
| Harmonic Analysis | Voltage and current: total harmonic, 128th harmonic, telephone harmonic factor, telephone interference factor, voltage deviation factor |
| Recording function | Up to 65536 steady-state data records, including 4 voltage, 4 current, 4 power, as well as total power factor and frequency |
| Protection function | When the tested voltage and current are greater than the set upper limit or lower than the set lower limit, the instrument will output an alarm |
| Transient testing | Calculate voltage, current, power, and frequency with a sampling interval of 20mS; Can capture the maximum and minimum values of each parameter within 12 seconds after the start of transient testing; And draw a data curve within 12 seconds. |
| Recording waves | Four modes are used to record the waveform of voltage or current, with a recording time of 2-17 seconds. |