PRG-1200/1220 output operation terminal isolation safety barrier
PRG-12 port is a 4-20mA output operation end isolation safety barrier that isolates and transmits 4-20mA signals from the safety zone to the hazardous side, driving on-site actuators, valves, and other equipment. This product requires independent power supply, with full isolation between the power supply, input, and output.
Main technical specifications
Working power supply: 20V-35Vdc
Power consumption: Approximately 1W for one input and one output (24V power supply, 20mA output) and approximately 2W for two inputs and two outputs (24V power supply, 20mA output)
Input signal range: 4mA~20mADC
Output signal range: 4mA~20mADC
Allowable output load capacity: 0~650 Ω
performance metrics
Insulation strength: 2500Vac/1 minute between the intrinsic safety end and non intrinsic safety end, 1000Vac/1 minute between the non intrinsic safety end
Output accuracy: 0.1% F.S
Temperature drift: 0.01% F.S/℃
Working temperature: -20 ℃~+60 ℃
Relative humidity: 35% to 85% RH
Storage temperature: -40 ℃ to+80 ℃
Structure and external dimensions
Product structure: 35mm rail mounted card type
ABS shell material
Plug in terminal
Dimensions: 22.5 × 114.5 × 99 (mm)
Whole machine weight: 150g
Product Features
Connected to valve positioners, electric/gas converters, wide range power supply, in compliance with EMC standards. The surrounding air of the installation site should not contain any corrosive media to chromium, nickel, or silver coatings. Suitable for site and equipment in Zone 0, Zone 1, Zone 2, Zone IIA, Zone IIB, and Zone IIC hazardous areas. Suitable for valve positioners and electric/gas converters
Safety and Explosion proof Certification Parameters
National Quality Supervision and Inspection Center for Explosion proof Electrical Products (CQST)
Explosion proof mark: [EXia] (IIC)
Authentication parameters: terminals (between 9.10 and 13.14)
Um=250V Uo = 28V Io = 93mA
Po =0.65W Lo = 2.4 mH Co = 0.05uF
wiring diagram

Outline dimension drawing (mm)