HomeYour location:Homeinstrumentation and metersRecording instrumentPaperless recorder → VX3000R Monochrome Paperless Recorder
Column tabs 
Product name: VX3000R Monochrome Paperless Recorder
specification: VX3000R Monochrome Paperless Recorder
  Zoom Zoom in on the image
Category: instrumentation and meters -- Paperless recorder
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


VX3000R Monochrome Paperless RecorderDetailed product description:Column tabs
VX3000R 12 channel input yellow screen paperless recorder, capable of inputting signals such as standard current, standard voltage, frequency, millivolts, thermocouples, and thermal resistors. It has sensor isolation distribution output, relay alarm output, transmission output, flow accumulation, temperature and pressure compensation, historical data transfer, printing, and remote communication functions.

Features of VX3000R Monochrome Paperless Recorder

5.1-inch 160 × 128 dot matrix graphic LCD display with LED backlight.
The screen contrast can be freely adjusted;
High speed, high-performance 32-bit ARM microprocessor, with a screen response time of less than 0.2 seconds, capable of simultaneously detecting, recording, displaying, and alarming 12 signals;
Using the latest large-scale integrated circuits and carefully designed components from internationally renowned factories;
Large capacity FLASH flash memory chips store historical data and never lose data in case of power failure;
Fully isolated universal input, capable of inputting multiple signals without the need for jumpers, can be configured through software;
The quantity display has a wide range of numerical values and can display 5-digit values: -9999 × 19999;
Support vacuum Scientific notation display;
Chinese menu configuration, display project tag number, and work unit. Software password lock ensures user configuration security;
Alarm display, indicating the lower and lower limits, lower and upper limits, and upper and upper limits of each channel alarm. Can record the last 15 alarm messages;
Use USB 2.0 interface to transfer and backup history records, supporting 256MB, 512MB, 1G USB drives;
Standard serial communication interfaces: RS-485 and RS-232C;
Standard Modbus communication protocol. In addition to supporting our company's ScanX data management software, it also supports popular professional configuration software such as iFIX, Kingview, MCGS, etc., without the need for dedicated drivers;
Can be connected to an external micro printer, supporting manual printing and timed automatic printing, meeting the needs of users for on-site printing;
Integrated hardware real-time clock, the clock can run accurately even in the event of power failure;
The new switch power supply operates normally within the range of 85VAC-256VAC;
Provide transmitter+24VDC isolated power distribution.
The compensation model is rich and can compensate for various media such as liquids, general gases, and steam.
The small flow supplement metering function compensates according to the set value after the instrument loses power.
Provide 8-hour shift, 12 hour shift reports, daily reports, and monthly reports. The settlement time can be freely set.
When the temperature sensor malfunctions, it will automatically switch to the set temperature and calculate the compensation amount based on the pressure.
It has a power-off recording function, which records the time of instrument power on and power-off, displays the cumulative power-off time, and prevents users from stealing steam during power outages.
The all aluminum sealed shell and internal shielding plate ensure the normal operation of the instrument in harsh environments.

Main technical specifications of VX3000R monochrome paperless recorder

Display: 5.1-inch 160 × 128 dot matrix TFT graphic LCD screen, LED backlight, wide viewing angle
Basic error: ± 0.2% F.S
Fully isolated universal input: 1-2 channel signal input, fully isolated between channels, isolation voltage>400V
Output specifications:
Distribution: 4 sets of 24VCD output, output current 60mA per set
12 configurable relay contact outputs, with a contact capacity of 3A and 250VAC (resistive load), default to normally open contacts.
Up to 4 analog outputs (transmission output or PID output), 4-20mADC, load resistance<600 Ω
Compensation calculation:
Steam: According to the steam density table, query the steam density and compensate for the mass flow rate and pressure of the steam
Range 0.1-22 Mpa
Temperature range 0-600 ℃
Water: According to the water density table, query the water density and compensate for the mass flow rate of water
Temperature range 0-150 ℃
Cumulative range: 0 to 99999999999
Communication and printing:
Communication interface: RS232C or RS485
Baud rates: 1200, 2400, 1800, 9600, 19200, 38400, 57600
Printing interface: RS232C directly connected to serial micro printing
Record time:
Record interval: 1, 2, 5, 10, 15, 30, 60, 120, 240 seconds optional.
Record length: 72 hours/pen (record interval of 1 second) to 720 days/pen (record interval of 4 minutes)
Data backup and transfer:
256MB~1G USB drive optional;
Cold end compensation error of thermocouple:
±1℃
Power outage protection:
Built in FLASH storage, protects parameters and historical data, and can be permanently saved after power failure. Integrated hardware clock that can operate accurately even after power failure.
Power Supply:
Switching power supply 85VAC~265VAC, 50Hz ± 5%, power consumption<59W
Environmental temperature:
0~50℃
ambient humidity:
0~85%RH