HomeYour location:HomePump valve fittingsPump productsperistaltic pump → JY15-12 series peristaltic pump
Column tabs 
Product name: JY15-12 series peristaltic pump
specification: JY15-12 series peristaltic pump
  Zoom Zoom in on the image
Category: Pump valve fittings -- peristaltic pump
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916950330

Email 91way@163.com
Wechat 13916950330(Wechat)


JY15-12 series peristaltic pumpDetailed product description:Column tabs
The JY15-12 series peristaltic pump is a product series of small volume, simple structure, and easy control formed by the JY15-12 pump head with multiple control methods. Mainly used in equipment and instruments to achieve fluid transmission below 170mL/min. The control method adopts a dip switch combined with external signals. The external signals can be selected from 4-20mA, 0-5V, 0-10V, 0-10kHz, and products with RS485 communication control mode can be provided. Adopting the bottom plate installation method and customizing products with panel installation method according to user requirements.

performance parameters

project parameter
speed range ≤100rpm
Dimensions (length * width * height) 118mm*60mm*96mm
Relative humidity of working environment <80%
Working environment temperature 0℃~40℃
Applicable power supply DC11.4V-25.2V,≤12W
Direction control External input empty contact point. The contact is normally open, and the peristaltic pump runs clockwise; The contact is normally closed, and the peristaltic pump runs counterclockwise.
start-stop control External input empty contact point. The contact is normally open, and the peristaltic pump is running; The contact is normally closed, and the peristaltic pump stops.
Dial switch speed control 16 speed BCD dip switch, 0 speed corresponds to external signal control, 1-F speed corresponds to 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 rpm.
External signal speed control (optional) 4-20mA linearly corresponds to 0.1-100rpm
0-5V linearly corresponds to 0-100rpm;
0-10V linearly corresponds to 0-100rpm;
0-10kHz linearly corresponds to 0-100rpm;
Speed control resolution 0.1rpm
Communication address setting 5-digit DIP dip switch, communication address setting range is 1-30, with 31 being the broadcast address.
Communication baud rate setting One DIP dip switch, available at 1200bps or 9600bps.

JY15-12 series peristaltic pump
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference