YYW Differential Vortex Flow MeterDetailed product description:Column tabs
YYW differential vortex flowmeter is a primary instrument used to measure the flow of liquid, gas, and steam in pipelines. It is a new type of intelligent flow meter based on the principle of Karman vortex street, with on-site LCD display function and variable output current signal or frequency signal for recording, adjustment, and control. YYW differential vortex flowmeter can be divided into full tube type, insertion type, and separation type according to different usage scenarios. In situations where it is inconvenient to provide power, battery powered low-power intelligent on-site display types can be selected. The YYW differential vortex flowmeter adopts embedded technology, which can measure signals such as flow rate, pressure, temperature, etc. It has nonlinear correction function and adopts RS-485 communication interface and MODBUS communication protocol, making it very convenient for networking. The transmission function of YYW differential vortex flowmeter is suitable for various distributed control systems and can also be combined with an upper computer to form a flow data acquisition system.

Performance characteristics
Two pairs of four piezoelectric crystal elements form a differential structure, which improves the vibration resistance and signal-to-noise ratio of the instrument

Extend the lower limit of flow velocity measurement to achieve low lower limit flow measurement;
It has the function of tracking and compensating for the temperature and pressure of the measured medium, and can accurately measure the mass flow rate of the medium;
Environmental conditions: ambient temperature -40 to+60 ℃; Relative humidity ≤ 85% RH;
Medium temperature: -40 to+300 ℃;
Flow rate range: liquid 0.5-7m/s, gas 5-50m/s, steam 5-70m/s;
Measurement accuracy: Full tube ± 1.0%, insertion ± 2.5%;
Power supply voltage: locally displayed 1.5-3.6V battery
Two line output 18-26V.DC
Pulse output 12-24V DC
Output signal: 2-wire 4-20mA analog current (load resistance ≤ 75O Ω);
Voltage pulse (load resistance ≥ 10k Ω)
RS-485 communication output
Fluid pressure: 0-4MPa (DN25-DN100);
O~2.5MPa(DN125~DN2000)
Intrinsic safety explosion-proof: explosion-proof mark Exia Ⅱ CT3-6, explosion-proof certificate number GYB00495, associated equipment LB902, LB902R
Explosion proof mark Exia Ⅱ CT2-5, explosion-proof certificate number GYB97131, associated equipment LB867, LB967
Explosion proof: Explosion proof mark Exd Ⅱ BT2-5, Explosion proof certificate number GYB00567
Factory inspection: The flowmeter is calibrated and qualified by the flow standard device before leaving the factory
Shell material: lCrl8Ni9Ti
Electrical connection: M20 × 1.5 internal thread, Φ 10 cable hole
Shell protection: IP65
Specifications: Full tube DN25-DN250, plug-in DN200-DN2000

Instrument selection
Key selection points
To ensure that the flowmeter operates under good characteristics, the following points should be noted when selecting a flowmeter:
1. The diameter of the flowmeter should be as small as possible to obtain a larger flow range and velocity;
2. The working pressure and temperature range of the tested medium should be within the technical parameter range;
3. The pressure loss coefficient Cd of the flowmeter is ≤ 2.4, and the flow pressure loss under working conditions can be estimated according to the following formula
ΔP =1.2×10-6ρV2
Δ P in the formula: pressure loss (MPa)
ρ: Fluid density under working conditions (kg/m3)
V: Flow velocity (m/s)
4. When the measuring medium is liquid, in order to prevent vaporization and cavitation, the minimum working pressure of the flowmeter should meet the following requirements:
P≥2.6ΔP+1.25P0
In the formula, P: minimum working pressure (MPa)
Δ P: Calculated value of pressure loss (MPa)
P0: Saturated vapor pressure of liquid (MPa)

Reference flow range

Caliber mm

Flow range (m)three/h)

Caliber mm Flow range (m)three/h)

liquid

gas

steam

liquid gas steam

twenty-five

0.8~12

7.2~60

12~120

three hundred

150~1500

1000~10000

1780~17800

thirty-two

1.5~20

13~100

20~200

four hundred

270~2700

1800~18000

3160~31600

forty

2~30

18~150

30~300

five hundred

420~4200

2800~28000

4950~49500

fifty

3~45

30~240

50~500

six hundred

610~6100

4070~40700

7120~71200

sixty-five

6.5~84

54~420

84~840

seven hundred

830~8300

5540~55400

9700~97000

eighty

10~130

70~600

120~1200

eight hundred

1090~10900

7230~72300

12700~127000

one hundred

20~200

120~1000

200~2000

nine hundred

1370~13700

9160~91600

16000~160000

one hundred and twenty-five

32~320

200~1600

320~3200

one thousand

1700~17000

11300~113000

19800~198000

one hundred and fifty

45~450

240~2000

440~4400

one thousand and two hundred

2440~24400

16300~163000

28500~285000

two hundred

90~900

480~4000

900~9000

one thousand and five hundred

3800~38000

25400~254000

44500~445000

two hundred and fifty

120~1200

700~8000

1200~12000

two thousand

7000~70000

48000~480000

80000~800000


Selection Table (Simply select each item from top to bottom to obtain the complete model)

YYW Vortex flowmeter series
code Detection category
A Differential type
code measuring medium
one gas
two liquid
three steam
code Nominal diameter of flowmeter
DN25 DN25
DN32 DN32

DN125 DN125
DN150 DN150
DN200 DN200
DN250 DN250 (insert type below)
DN300 DN300

DN2000 DN2000
code power supply
D DC 24V power supply
T Battery powered (only for local display with no signal output)
code Display the header in place (option)
X Intelligent LCD display screen
code Supporting pressure and temperature sensors (only temperature and pressure compensation table options available)
P pressure
T temperature
Q Pressure and temperature
code output signal

Two line system with 4-20mA output
I Three wire voltage pulse output
T RS485 communication output
code Pipeline connection method (full pipe option only)
R flange type
code Header combination type (option)
L Header separation type
code Ball valve (insert only option)
Z Install ball valve
code Explosion proof mark (option)
B Intrinsic safety explosion-proof
d flameproof
YYWA 1DN100D X Q Ⅲ R -- B Selection Example

The model must be filled in completely and clearly for accurate supply;  
Go to YYW capacitive vortex flowmeter
The option bar code is only to be filled in when needed;
Integrated installation of pressure and temperature sensors and flow meters for pressure and temperature compensation gauges; When the measuring medium is steam, the pressure sensor must be installed on the pipeline.
YYW Differential Vortex Flow Meter
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference