| Product name: | CJR4/4 Infrared Methane and Carbon Dioxide Analyzer | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- gas detection | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Project Name |
Main technical parameters and performance |
|
Environmental conditions for use |
Working temperature: -20~40 ℃, relative humidity: ≤ 96%, storage temperature: -20~60 ℃ Air pressure: 80-110 kPa, wind speed: ≤ 8m/s, underground mines with methane explosive gas. |
|
Display method |
Four digit red illuminated digital display |
|
resolution |
Methane 0.01% CH4, carbon dioxide 0.01% CO2 |
|
working method |
Diffusion |
|
A alkane ministry part |
Measurement range: 0-4% CH4 |
|
Measurement error: ≤ ± 0.1% CH4 when 0-1% CH4 is present; >At 1% CH4, ≤ ± 10% of the true value | |
|
Response time:<30s | |
|
Alarm range: The alarm point can be set arbitrarily within the range of 0.5-2% CH4 (Factory setting 1.00% CH4), can be checked and adjusted at any time. | |
|
Alarm error: Same as measurement error | |
|
Alarm mode: flashing red numbers, alarm sound | |
|
Sound level intensity: ≥ 80dB | |
|
Probe lifespan: ≥ 2 years | |
|
Carbon dioxide component |
Measurement range: 0-4% COtwotime |
|
Measurement error: When 0-1% CO2, ≤± 0.05 CO2two%When ≤ 1% CO2, ≤ ± 5% of the true value | |
|
Response time:<60s | |
|
Alarm range: The alarm point can be set arbitrarily within the range of 0.1-2% CO2 (Factory setting 18.0% Otwo)It can be checked or adjusted at any time. | |
|
Alarm error: Same as measurement error | |
|
Alarm mode: flashing red numbers, alarm sound | |
|
Sound level intensity: ≥ 80dB | |
|
Probe lifespan | |
|
clock part |
Format: 24-hour format |
|
Display content: hours, minutes | |
|
Error: ≤± 1 minute/24 hours (can be manually corrected) | |
|
Battery operation Voltage section |
Measurement range: 4.4-6V |
|
Measurement error: ≤± 0.01% V | |
|
Display mode: Display voltage value after the letter E | |
|
Digital Automatic Record and storage function |
Record format: time methane concentration carbon dioxide concentration |
|
Storage method: When methane and carbon dioxide are not alarmed, a frame of data is automatically recorded and stored every half hour. When methane or oxygen alarms, record and store 1 frame of data every 10 seconds. When the carbon dioxide alarm is triggered, a frame of data is automatically recorded and stored every minute. | |
|
Storage capacity: 80 frames (can be increased according to user requirements) | |
|
Soft adjustment function |
Adjustment method: button type |
|
Adjustment content: zero point, calibration, etc | |
|
Undervoltage alarm and undervoltage automatic shutdown function |
When the working voltage of the battery is ≤ 4.4V, the undervoltage value flashes and automatically shuts down after 2 seconds. |
|
Super concentration alarm and automatic shutdown function |
Methane concentration ≥ 5% CHfourWhen the super concentration value flashes, it will automatically shut down after 2 seconds |
|
Continuous working time for one charge |
>9h |
|
Charging life of battery pack |
>500 times |
|
Maximum operating current of the whole machine |
Normal operating current 110mA (150mA in case of alarm) |
|
Intrinsic safety power supply |
4 x NiHi1.8Ah, maximum open circuit voltage 5.5, rated voltage 4.8V, maximum short-circuit current 4.0A, battery pack encapsulated with epoxy resin, current limiting resistor resistance 1.5 Ω, power 15-20W |
|
Explosion-proof marking |
ExDibl |
|
Form of riot control |
Mining intrinsic safety and explosion-proof type |
|
Overall dimensions |
127×66×30mm |
|
weight |
330g |
|
Safety Sign Permit: Coal Technology Supervision Certificate No. 20012020 | |