HomeYour location:HomeHigh voltage electrical appliancesdischarge coilDry discharge coil → FDZR2-4.0/12(-1W) type discharge coil
Column tabs 
Product name: FDZR2-4.0/12(-1W) type discharge coil
specification: FDZR2-4.0/12(-1W) type discharge coil
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Dry discharge coil
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


FDZR2-4.0/12(-1W) type discharge coilDetailed product description:Column tabs
The FDZR2-4.0/12/√ 3 (-1W) discharge coil is a fully enclosed structure made of (outdoor) epoxy resin casting, suitable for connecting with high-voltage parallel capacitors in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It enables the rapid release of residual charges after the capacitor bank is disconnected from the power system, effectively preventing the occurrence of closing overvoltage and overcurrent that may endanger equipment safety due to the capacitor still carrying charges when the capacitor bank is closed again, and ensuring the safety of maintenance personnel. This series of products comes with a secondary winding, which can be used for line monitoring, measurement, and secondary protection.

Technical parameters of FDZR2-4.0/12/√ 3 (-1W) discharge coil

System nominal voltage (kV)
ten
Rated voltage of primary winding (kV)
6.6/√3; 7.2/√3; 11/√3; 12/√3
Rated voltage of secondary winding (V)
100; 100/√3
Rated load of secondary winding (VA)
50VA
accuracy level
zero point five
Supporting capacitor bank capacity (Mvar)
0.5-4.0
insulation level
12/42/75kV
discharge time
At rated operating voltage, the residual voltage of the capacitor shall not drop to 50V for more than 5 seconds after power failure
Partial discharge level
≤5pC
Wiring method: Reduced level
Number of phases: single-phase
Frequency: 50Hz
Creepage distance: The external insulation creepage distance shall not be less than 31mm/kV


Note: If there are special requirements, they can be determined after consultation with our company.

Product outline drawing:

Installation dimensions of FDZR2-4.0/12 (-1W) discharge coil
FDZR2-4.0/12 (-1W) discharge coil

FDZR2-4.0/12(-1W) type discharge coil
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference