| Product name: | RK8510 series electronic load tester | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Load devices | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
model |
RK8511 |
RK8512 | |||
|
Rated input |
power |
150W |
300W | ||
|
current |
0-30A |
0-60A | |||
|
voltage |
0-150V |
0-150V | |||
|
constant current mode |
scope |
0-3A |
0-30A |
0-6A |
0-60A |
|
resolution |
0.1mA |
1mA |
0.1mA |
1mA | |
|
accuracy |
0.03%+0.5%FS |
0.03%+0.5%FS |
0.03%+0.5%FS |
0.03%+0.5%FS | |
|
Fixed voltage mode |
scope |
0.1-19.999V |
0.1-150V |
0.1-19.999V |
0.1-150V |
|
resolution |
1mV |
10mV |
1mV |
10mV | |
|
accuracy |
0.03%+0.02%FS |
0.03%+0.02%FS |
0.03%+0.02%FS |
0.03%+0.02%FS | |
|
Fixed resistance mode when the input voltage and resistance value are ≥ 10% of the full range |
scope |
0.03Ω-10K |
0.03Ω-5K |
0.03Ω-10K |
0.03Ω-5K |
|
resolution |
16 bits |
16 bits |
16 bits |
16 bits | |
|
accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
Fixed power mode (when input voltage and current values are ≤ 10% of full scale) |
scope |
0-150W |
0-150W |
0-300W |
0-300 |
|
resolution |
1mV |
10mV |
1mV |
10mV | |
|
accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
Voltage measurement value |
voltage |
0.19.999V |
0-150V |
0.19.999V |
0-150V |
|
resolution |
1mV |
10mV |
1mV |
10mV | |
|
accuracy |
0.015%+0.03%FS |
0.015%+0.03%FS |
0.015%+0.03%FS |
0.015%+0.03%FS | |
|
Current measurement value |
current |
0-3A |
0-30A |
0-6A |
0-60A |
|
resolution |
0.01mA |
0.1mA |
0.1mA |
1mA | |
|
accuracy |
0.03%0.05%FS |
0.03%0.08%FS |
0.03%0.05%FS |
0.03%0.08%FS | |
|
Power measurement value (when input voltage and current values are ≥ 10% of full scale) |
watt |
100W |
150W |
100W |
300W |
|
resolution |
1mW |
10mW |
1mW |
10mW | |
|
accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
Battery testing function Battery input: 0.5-120V; Maximum measurement: Capacity=999/H; Resolution=0.1mA; Time range=1S-16HS | |||||
|
Dynamic testing function conversion table: 0-25kHz; 2.5A/uS; T1&T2:60uS-999S; Accuracy ± 15% deviation+10% FS | |||||
|
Current soft start time 1mS; 2mS; 5mS;10mS; 20mS;50mS; 100mS;200mS; Accuracy ± 15% deviation+10% FS | |||||
|
Short circuit function |
Current (CC) |
≈3.3A |
≈33A |
≈6.6A |
66A |
|
Voltage (CV) |
0V |
0V | |||
|
Resistance (CR) |
≈55mΩ |
≈25mΩ | |||
|
temperature |
operation |
0~40℃ |
0~40℃ | ||
|
Non-operable |
-10℃~70℃ |
-10℃~70℃ | |||
|
Overall dimensions |
Width * Length * Height |
108*214*365 | |||
|
weight |
Kg |
three point five | |||
RK8510 series electronic load tester