HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer220KV current transformer → LVQB-110/220 outdoor sulfur hexafluoride current transformer
Column tabs 
Product name: LVQB-110/220 outdoor sulfur hexafluoride current transformer
specification: LVQB-110/220 outdoor sulfur hexafluoride current transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 220KV current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


LVQB-110/220 outdoor sulfur hexafluoride current transformerDetailed product description:Column tabs
LVQB-110/220 Outdoor Sulfur Hexafluoride Current Transformer
Overview
LVQB-110 and LVQB-220 SF6 current transformers are electromagnetic current transformers developed and produced to meet the needs of the power market, using SF6 gas as the insulation medium. The products meet the requirements of GB1208-1997 and relevant IEC standards, and have passed the testing of the Electrical Equipment Quality Inspection and Testing Center of the Ministry of Electric Power Industry, as well as the inspection of the State Machinery Industry Bureau and the State Power Company
Technical appraisal. This current transformer plays a role in electrical protection and measurement in AC 50Hz, 110KV, and 220KV high-voltage transmission and transformation systems.

product structure
The overall structure of the product is inverted, mainly composed of three parts: shell, sleeve, and base. The shell is located at the top of the product, and both the primary and secondary windings are installed inside the shell. The primary winding is connected to the secondary winding
Passing through the middle of the group, they are insulated with SF6 gas. The shell is equipotential with the primary circuit and insulated from the base through a sleeve. The secondary winding is fixed inside the shell by insulating components, and its leads are connected to the secondary wiring terminals in the base through metal shielding tubes in the sleeve, for users to connect to measuring or protective loads. The base is equipped with adsorbents, secondary wiring boards, and SF6 pointer type density relays.

Terms of Use
Environmental temperature: -40 ℃~+40 ℃
Altitude: ≤ 3000m
Wind pressure: ≤ 700Pa
Seismic intensity: ≤ 8 degrees

Ordering Instructions
Please specify when placing an order:
Model and name of current transformer
rated current ratio
Number of required secondary coils, accuracy level, and rated output
External insulation type (silicone rubber insulation, porcelain insulation)
Required spare parts, accessories, and other special requirements
Product quantity and delivery time

Technical parameters of LVQB-220 current transformer

serial number
name
unit
data
one
Rated short-time power frequency withstand voltage (1-minute effective value)
KV
three hundred and ninety-five
two
Rated lightning impulse withstand voltage (full wave 1.2/50 μ s) (peak)
KV
nine hundred and fifty
three
Rated lightning impulse withstand voltage (cut-off 2-5 μ s) (peak value)
KV
one thousand and ninety-three
four
Partial discharge capacity
PC
≤5
five
Rated pressure of SF6 gas (20 ℃)
MPa
zero point four
six
SF6 gas replenishment pressure (20 ℃)
MPa
zero point three five
seven
Creepage distance ratio
≥25
eight
Annual SF6 gas leakage rate
mm/kv
≤1%
nine
SF6 gas moisture content
V/V
≤ 250 × 10-6 (factory control value)
≤ 500 × 10-6 (allowable operating value)
ten
Weight of SF6 gas per unit/total weight per unit
kg
18/1200

serial number
Current ratio A
Rated once
Current A
Rated secondary
Current A
measurement level
protection level
Rated output VA
3S short-term heat
Current kA
Rated dynamic stability
Constant current kA
accuracy level
Instrument security factor
accuracy level
Accurate limit coefficient
measurement level
protection level
one
2×300/5
three hundred
5 or 1
0.2 or 0.5 level
FS5 or FS10
5P level
or
10P level
twenty
thirty
fifty
thirty-one point five
eighty
six hundred
fifty
one hundred and twenty-five
two
2×400/5
four hundred
thirty-one point five
eighty
eight hundred
fifty
one hundred and twenty-five
three
2×500/5
five hundred
forty
thirty-one point five
eighty
one thousand
fifty
one hundred and twenty-five
four
2×600/5
six hundred
thirty-one point five
eighty
one thousand and two hundred
fifty
one hundred and twenty-five
five
1500/5
one thousand and five hundred
fifty
sixty
six
2000/5
two thousand
sixty
seven
2500/5
two thousand and five hundred

Note: 1. Each product can come with six secondary coils; 2. When the user has special requirements, they can be resolved through negotiation.

Technical parameters of LVQB-110 current transformer

serial number
name
unit
data
one
Rated short-time power frequency withstand voltage (1-minute effective value)
kV
two hundred and thirty
two
Rated lightning impulse withstand voltage (peak) (full wave 1.2/50 μ s)
kV
five hundred and fifty
three
Rated lightning impulse withstand voltage (peak) (cut-off 2-5 μ s)
kV
six hundred and thirty-three
four
Rated short-time thermal current (effective value)
kA
55-87
five
Rated dynamic stability current (peak value)
kA
100-125
six
Partial discharge capacity
PC
≤5
seven
Rated pressure of SF6 gas (20 ℃)
MPa
zero point four
eight
SF6 gas replenishment pressure (20 ℃)
MPa
zero point three five
nine
Minimum creepage distance
mm/kv
≥25
ten
Annual SF6 gas leakage rate
≤1%
eleven
SF6 gas moisture content
V/V
≤ 250 × 10-6 (factory value)
≤ 500 × 10-6 (operating value)
twelve
Weight of SF6 gas per unit/total weight per unit
kg
7-500

serial number
current ratio
A
Rated once
Current A
Rated secondary
Current A
measurement level
protection level
Rated output VA
accuracy level
Instrument security factor
accuracy level
Accurate limit coefficient
measurement level
protection level
one
2×200/5
two hundred
5 or 1
Level 0.2
or
Level 0.5
FS5
or
FS10
5P level
or
10P level
twenty
thirty
thirty
four hundred
two
2×300/5
three hundred
forty
six hundred
three
2×400/5
four hundred
eight hundred
four
2×500/5
five hundred
fifty
one thousand
five
2×600/5
six hundred
one thousand and two hundred
six
750-1500/5
seven hundred and fifty
thirty
thirty
one thousand and five hundred
fifty
fifty
seven
1000-2000/5
one thousand
thirty
thirty
two thousand
fifty
fifty
Note: 1. Each product can come with 4 secondary coils; 2. When the user has special requirements, they can be resolved through negotiation.


Outline drawing of LVQB-110 SF6 current transformer product

Outline dimension drawing of LVQB-110 outdoor sulfur hexafluoride current transformer

Outline drawing of LVQB-220 SF6 current transformer product

Outline dimension drawing of LVQB-220 outdoor sulfur hexafluoride current transformer