| Product name: | YDG series current sensor | ||||||
| specification: | YDG-HSD-1-□A | ![]() |
|||||
| Category: | instrumentation and meters -- SENECA Transducers | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
Model: YDG-HSD-1- □ A
Name: YDG Series Current Sensor
Detailed information:
Main functions and features
It can measure the current of any waveform, and the output terminal can truly reflect the waveform parameters of the input terminal current or voltage. The temperature compensation circuit is used to control the waveform parameters, effectively reducing the impact of temperature drift on measurement accuracy, ensuring high measurement accuracy, easy installation, and low price
Model description and parameters
For example: YDG-HSD-1-100A
Name: Hall current sensor
Input: 0-100A (AC or DC)
Output: 0-4V (AC or DC) Ordering instructions:
When placing an order, please ask the user to specify the parameters.
performance metrics
Overload capacity: 2 times continuous, 20 times 1-second
Accuracy:<1.0% 1N
Linearity: better than 0.2%
Unbalanced voltage: less than ± 20mV
Temperature drift: better than ± 100ppm/℃
Reaction time: less than 10 µ s
Frequency characteristics: 0-10kHz
Power frequency withstand voltage: AC2kV/min.1mA
Working environment: 0-45 ℃
Working power supply: ± 12V~± 15V,+12V,+15V
Power consumption: ≤ 30mA
Flame retardant properties: UL94-V0
Protection: Built in power surge and polarity reversal protection
Execution standard: QB/44160017113-2002
Shell material: Flame retardant plastic (blue)
Isolation: Input/output isolation
Structure: Pin wiring
Pin wiring
1. Positive working power supply terminal
2. Negative working power supply terminal
3. Measurement output terminal
4. Public grounding terminal
Precautions
The working power supply and output terminal must be connected correctly and cannot be misconnected
For the two potentiometers, please do not adjust them randomly. If calibration is required, use a small screwdriver to slowly rotate them to the desired accuracy. The temperature of the primary busbar should not exceed 60 ℃
When the current busbar is filled with the original edge threading hole, the best measurement accuracy should be obtained. The usage environment should be free of conductive dust, corrosive metals, and gases that damage insulation, and the altitude should be less than 2500 meters
When measuring DC current, the direction of the current should be in the same direction as the arrow marked on the product casing to obtain positive output selection. Please pay special attention to the wire diameter and external dimensions of the input line to select a product that meets the requirements.
Overall dimensions