| Product name: | S-15 Type Switching Power Supply | ||||||
| specification: | ![]() |
||||||
| Category: | transformer equipment -- switching power supply | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| |||||
|
model performance |
S-15-5 | S-15-12 | S-15-24 | ||
| DC output voltage | 5V | 12V | 24V | ||
| Output voltage tolerance (Note 2) | ±2% | ±1% | ±1% | ||
| Rated output current | 3A | 1.3A | 0.7A | ||
| Output current range | 0-3A | 0-1.3A | 0-0.7A | ||
| Ripple and noise (Note 3) | 50mVp-p | 50mVp-p | 100mVp-p | ||
| Stability of incoming line (Note 4) | ±0.5% | ±0.5% | ±0.5% | ||
| Load stability (Note 5) | ±1% | ±0.5% | ±0.5% | ||
| DC output power | 15W | 15.6W | 16.8W | ||
| efficiency | 65% | 68% | 72% | ||
| Adjustable range of DC voltage | ±10,-5% | ±10% | ±10% | ||
| Input voltage range | 85-132VAC/170-264VAC switch selection 47-63Hz; 240-370VDC | ||||
| input current | 0.3A/115V 0.18A/230V | ||||
| inrush current | Cold start current 15A/115V 30A/230V | ||||
| leakage current | < 0.5mA/240VAC | ||||
| overload protection |
115%~150% current limit reset: automatic recovery | ||||
| overvoltage protection | …… | ||||
| High-temperature protection | …… | ||||
| temperature coefficient | ±0.02%/℃(0~50℃) | ||||
| Start, rise, and hold time | 200ms,100ms,30ms | ||||
| seismic resistance | 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis | ||||
| pressure resistance |
Input/output room: 1.5KVAC Input and enclosure: 1.5KVAC Output and enclosure: 0.5KVAC | ||||
| Isolation resistor | Between input and output, input and casing, output and casing: 500VDC/100M Ω | ||||
| Working temperature and humidity | -10℃~+50℃,20%~90%RH | ||||
| Storage temperature, temperature | -20℃~+85℃,10%~95RH | ||||
| Overall dimensions | 99*97*35mm | ||||
| weight | 0.3Kg | ||||
| safety standards | Meet UL1012 requirements | ||||
| EMC standard | …… | ||||
| Other Performance | …… | ||||
| Note: 1. The above parameter testing conditions are: 230VAC input, rated load, 25 ℃ 70% RH. Humidity. 2. Tolerance: including set tolerance, line stability, and load stability (Note 5). 3. Ripple test: Use A12 "twisted pair for 20MHz and short-circuit with 0.1uF&47uF capacitors for interruption. 4. Incoming voltage stability test: the lowest voltage to the highest voltage of the incoming line at full load. 5. Load stability test: load from 0% to 100%. | |||||
S-15 Switching Power Supply