S-40 Type Switching Power SupplyDetailed product description:Column tabs
model
performance
S-40-5 S-40-12 S-40-15 S-40-24
DC output voltage 5V 12V 15V 24V
Output voltage tolerance (Note 2) ±2% ±1% ±1% ±1%
Rated output current 8A 3.5A 2.8A 1.8A
Output current range 0-8A 0-3.5A 0-2.8A 0-1.8A
Ripple and noise (Note 3) 75mVp-p 100mVp-p 100mVp-p 100mVp-p
Stability of incoming line (Note 4) ±0.5% ±0.5% ±0.5% ±0.5%
Load stability (Note 5) ±1% ±0.5% ±0.5% ±0.5%
DC output power 40W 42W 42W 43W
efficiency 72%/115VAC 76%/115VAC 76%/115VAC 78%/115VAC
Adjustable range of DC voltage +10,-5% ±10% ±10% ±10%
Input voltage range 100~240VAC 47~63Hz; 120~370VDC
input current 1.2A/115V 0.6A/230V
inrush current Cold start current 30A/115V 60A/230V
leakage current < 1mA/240VAC
overload protection

150% to 200% cut-off output reset: automatic recovery

overvoltage protection 115%~135%
High-temperature protection ……
temperature coefficient ±0.03%/℃(0~50℃)
Start, rise, and hold time 800ms,50ms,15ms/115VAC 300ms,50ms,60ms/230VAC
seismic resistance 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis
pressure resistance

Input/output room: 3KVAC, input and enclosure: 1.5KVAC, output and enclosure: 0.5KVAC

Isolation resistor Between input and output, input and casing, output and casing: 500VDC/100M Ω
Working temperature and humidity -10℃~+50℃,20%~90%RH
Storage temperature, temperature -20℃~+85℃,10%~95RH
Overall dimensions 129*98*38mm
weight 0.45Kg
safety standards UL1012,EN60950
EMC standard EN55022,EN55024,EN61000,IEC801-2,3,4,IEC555-2
Other Performance ……

Note:
1. The above parameter testing conditions are: 230VAC input, rated load, 25 ℃ 70% RH. Humidity.
2. Tolerance: including set tolerance, line stability, and load stability (Note 5).
3. Ripple test: Use A12 "twisted pair for 20MHz and short-circuit with 0.1uF&47uF capacitors for interruption.
4. Incoming voltage stability test: the lowest voltage to the highest voltage of the incoming line at full load.
5. Load stability test: load from 0% to 100%.
6 C2, 3-6 must be dismantled