S-50 Type Switching Power SupplyDetailed product description:Column tabs
model
performance
S-50-5 S-50-12 S-50-15 S-50-24
DC output voltage 5V 12V 15V 24V
Output voltage tolerance (Note 2) ±2% ±1% ±1% ±1%
Rated output current 10A 4.2A 3.4A 2.1A
Output current range 0-10A 0-4.2A 0-3.4A 0-2.1A
Ripple and noise (Note 3) 75mVp-p 100mVp-p 100mVp-p 100mVp-p
Stability of incoming line (Note 4) ±0.5% ±0.5% ±0.5% ±0.5%
Load stability (Note 5) ±1% ±0.5% ±0.5% ±0.5%
DC output power 50W 50.4W 50.4W 51W
efficiency 71% 78% 78% 82%
Adjustable range of DC voltage +10,-5% ±10% ±10% ±10%
Input voltage range 85-132VAC/170-264VAC select 47-63Hz; 240-370VDC
input current 1.3A/115V 0.65A/230V
inrush current Cold start current: 18A/115V, 36A/230V
leakage current < 0.5mA/240VAC
overload protection

115%~150% current limit reset: automatic recovery

overvoltage protection ……
High-temperature protection ……
temperature coefficient ±0.03%/℃(0~50℃)
Start, rise, and hold time 200ms,100ms,30ms
seismic resistance 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis
pressure resistance

Input/output room: 1.5KVAC, input and enclosure: 1.5KVAC, output and enclosure: 0.5KVAC

Isolation resistor Between input and output, input and casing, output and casing: 500VDC/100M Ω
Working temperature and humidity -10℃~+50℃,20%~90%RH
Storage temperature, temperature -20℃~+85℃,10%~95RH
Overall dimensions 159*97*38mm
weight 0.5Kg
safety standards Meets UL1012
EMC standard EN55022,EN55024,EN61000
Other Performance ……

Note:
1. The above parameter testing conditions are: 230VAC input, rated load, 25 ℃ 70% RH. Humidity.
2. Tolerance: including set tolerance, line stability, and load stability (Note 5).
3. Ripple test: Use A12 "twisted pair for 20MHz and short-circuit with 0.1uF&47uF capacitors for interruption.
4. Incoming voltage stability test: the lowest voltage to the highest voltage of the incoming line at full load.
5. Load stability test: load from 0% to 100%.