| Product name: | S-100 Type Switching Power Supply | ||||||
| specification: | ![]() |
||||||
| Category: | transformer equipment -- switching power supply | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
Low price, high reliability
105 ℃ output capacitor
Global applicable AC input voltage
High efficiency, low working temperature
Soft start current, effectively reducing AC input shock
Small size and light weight
100% full load burning test
Built in EMI filter with minimal ripple
|
model performance |
S-100-3 | S-100-5 | S-100-7-5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
| DC output voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
| Output voltage tolerance (Note 2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
| Output current range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
| Ripple and noise (Note 3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Stability of incoming line (Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
| Load stability (Note 5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
| DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
| efficiency | 70% | 78% | 80% | 81% | 81% | 84% | 84% | 84% |
| Adjustable range of DC voltage | 2.85-3.3V | 4.75-5.5V | 6.75-8.25V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
| Input voltage range | 85-132VAC/180-264VAC select 47-63Hz; 255-370VDC | |||||||
| input current | 1.9A/115V 1A/230V | |||||||
| inrush current | Cold start current 30A/115V 60A/230V | |||||||
| leakage current | < 1mA/240VAC | |||||||
| overload protection | 115%~150% cut off output reset: restart | |||||||
| overvoltage protection | …… | |||||||
| High-temperature protection | …… | |||||||
| temperature coefficient | ±0.03%/℃(0~50℃) | |||||||
| Start, rise, and hold time | 200ms,100ms,20ms | |||||||
| seismic resistance | 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis | |||||||
| pressure resistance |
Input/output room: 1.5KVAC, input and enclosure: 1.5KVAC, output and enclosure: 0.5KVAC | |||||||
| Isolation resistor | Between input and output, input and casing, output and casing: 500VDC/100M Ω | |||||||
| Working temperature and humidity | -10℃~+50℃,20%~90%RH | |||||||
| Storage temperature, temperature | -20℃~+85℃,10%~95RH | |||||||
| Overall dimensions | 199*98*38mm | |||||||
| weight | 0.65Kg | |||||||
| safety standards | Meets UL1012 | |||||||
| EMC standard | EN55022,EN55024,EN6100 | |||||||