HomeYour location:Hometransformer equipmentpower supply equipmentswitching power supply → S-100F Type Switching Power Supply
Column tabs 
Product name: S-100F Type Switching Power Supply
specification: S-100F Type Switching Power Supply
  Zoom Zoom in on the image
Category: transformer equipment -- switching power supply
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


S-100F Type Switching Power SupplyDetailed product description:Column tabs
S-100F Switching Power Supply

  • Low price, high reliability
  • 105 ℃ output capacitor
  • Global applicable AC input voltage
  • High efficiency, low working temperature
  • Soft start current, effectively reducing AC input shock
  • Has short-circuit protection and overload protection
  • Small size and light weight
  • 100% full load burning test
  • Built in EMI filter with minimal ripple
  • model
    performance
    S-100F-5 S-100F-7.5 S-100F-12 S-100F-15 S-100F-24 S-100-48
    DC output voltage 5V 7.5V 12V 15V 24V 48V
    Output voltage tolerance (Note 2) ±2% ±1% ±1% ±1% ±1% ±1%
    Rated output current 20A 13.5A 8.5A 6.7A 4.5A 2.2A
    Output current range 0-20A 0-13.5A 0-8.5A 0-6.7A 0-4.5A 0-2.2A
    Ripple and noise (Note 3) 100mVp-p 125mVp-p 125mVp-p 125mVp-p 150mVp-p 150mVp-p
    Stability of incoming line (Note 4) ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
    Load stability (Note 5) ±1% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
    DC output power 100W 101W 102W 100.5W 108W 105.6W
    efficiency 76% 78% 80% 81% 83% 84%
    Adjustable range of DC voltage +10% ±10% ±10% ±10% ±10% ±10%
    Input voltage range Select 47-63Hz for 100-120VAC/200-240VAC; 248-370VDC
    input current 2.4A/115V 1.2A/230V
    inrush current Cold start current 30A/115V 60A/230V
    leakage current < 1mA/240VAC
    overload protection

    115%~150% cut off output reset: automatic recovery

    overvoltage protection 115%~135%
    High-temperature protection ……
    temperature coefficient ±0.03%/℃(0~50℃)
    Start, rise, and hold time 1ms,30ms,15ms
    seismic resistance 10-500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis
    pressure resistance

    Input/output room: 3KVAC, input and enclosure: 1.5KVAC, output and enclosure: 0.5KVAC

    Isolation resistor Between input and output, input and casing, output and casing: 500VDC/100M Ω
    Working temperature and humidity -10℃~+50℃,20%~90%RH
    Storage temperature, temperature -20℃~+85℃,10%~95RH
    Overall dimensions 199*98*38mm
    weight 0.65Kg
    safety standards UL1012,EN60950
    EMC standard EN55022,EN55024,EN61000,IEC801-2,3,4,IEC555-2
    Other Performance ……
    Note: 1. The above parameter testing conditions are: 230VAC input, rated load, 25 ℃ 70% RH. Humidity.
    2. Tolerance: including set tolerance, line stability, and load stability (Note 5).
    3. Ripple test: Use A12 "twisted pair for 20MHz and short-circuit with 0.1uF&47uF capacitors for interruption.
    4. Incoming voltage stability test: the lowest voltage to the highest voltage of the incoming line at full load.
    5. Load stability test: load from 0% to 100%.
    6 C3, 4.32 must be dismantled

    Dimensions of S-100F Switching Power Supply

    S-100F Type Switching Power Supply
    Product Category