| Product name: | 3KVA~300KVA series single-phase (vertical) variable frequency power supply | ||||||
| specification: | ![]() |
||||||
| Category: | transformer equipment -- Variable Frequency Power Supply | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| Technical parameters for 3KVA to 30KVA | |||||||||
|
Model FAF |
eleven thousand and three |
eleven thousand and five |
eleven thousand and six |
eleven thousand and ten |
thirty-one thousand and fifteen |
thirty-one thousand and twenty |
thirty-one thousand and thirty | ||
|
output capacity |
3KVA |
5KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA | ||
|
Circuit method |
IGBT/PWM Pulse Width Modulation Method | ||||||||
|
Input (communication) |
phase number |
1Φ2W+G |
3Φ4W+G | ||||||
|
Voltage |
220V±10% |
380V±10% | |||||||
|
frequency |
50Hz±3Hz/60Hz±3Hz | ||||||||
|
Output (communication) |
phase number |
1Φ2W+G | |||||||
|
Voltage |
low-end |
0~150V (L-N) | |||||||
|
high-end |
0~300V(L-N) | ||||||||
|
frequency |
45-70Hz, 50Hz, 60Hz, 400Hz, 2F (2nd harmonic), 4F (4th harmonic) | ||||||||
|
40-500Hz (option) | |||||||||
|
Maximum current |
low-end |
25A |
42A |
50A |
84A |
125A |
168A |
250A | |
|
high-end |
12.5A |
21A |
25A |
42A |
63A |
84A |
125A | ||
|
Frequency stability |
≤0.01% | ||||||||
|
load regulation |
± 0.5% (linear load) | ||||||||
|
Waveform Distortion (THD) |
1.5% (linear load) | ||||||||
|
reaction time |
Maximum value 2ms | ||||||||
|
Instructions/Resolution |
4-digit frequency table |
Resolution 0.1Hz | |||||||
|
4-digit voltmeter |
Resolution 0.1V | ||||||||
|
4-digit ammeter |
Resolution below 4A 0.001A; Resolution above 4A 0.01A | ||||||||
|
4-digit wattmeter |
Resolution below 200W: 0.1W; Resolution above 200W: 1W | ||||||||
|
protective device |
Input/output no fuse switch, electronic circuit quickly detects overvoltage, overcurrent, overload | ||||||||
|
High temperature and short circuit automatic tripping protection and alarm device | |||||||||
|
Insulation reactance |
DC500V20M Ω or above | ||||||||
|
voltage-resistant insulation |
AC1800V/5mA/1 minute | ||||||||
|
Cooling device |
Forced fan cooling | ||||||||
|
environment |
Operating Temperature |
0℃~50℃ | |||||||
|
relative humidity |
0-90% (non condensing state) | ||||||||
|
altitude |
1500m | ||||||||
|
Dimensions (width x depth x height) mm |
430×520×650 |
550×520×740 |
580×820×1060 | ||||||
|
Net weight (kg) |
forty-eight |
sixty-three |
eighty |
one hundred and forty-five |
one hundred and seventy-five |
two hundred and eighty-five |
three hundred and eighty-five | ||
| Note: The maximum power of this series is single-phase 300KVA, with a maximum output frequency of 1000Hz and a maximum output voltage of 1000V; | |||||||||
| F=input power frequency, when the input frequency is 50Hz, 2F output frequency=2x input frequency=2x50Hz=100Hz; | |||||||||
| Specially made according to customer requirements for specifications; | |||||||||
| Our company continuously develops and improves specifications, and changes are subject to change without prior notice. For detailed information, please consult our business. | |||||||||
| Technical parameters for 45KVA to 300KVA | ||||||||||
|
Model FAF |
thirty-one thousand and forty-five |
thirty-one thousand and sixty |
thirty-one thousand and one hundred |
thirty-one thousand one hundred and twenty |
thirty-one thousand one hundred and fifty |
thirty-one thousand one hundred and eighty |
thirty-one thousand and two hundred |
thirty-one thousand and three hundred | ||
|
output capacity |
45KVA |
60KVA |
100KVA |
120KVA |
150KVA |
180KVA |
200KVA |
300KVA | ||
|
Circuit method |
IGBT/PWM Pulse Width Modulation Method | |||||||||
|
Input (communication) |
phase number |
3Φ4W+G | ||||||||
|
Voltage |
380V±10% | |||||||||
|
frequency |
50Hz±3Hz/60Hz±3Hz | |||||||||
|
Output (communication) |
phase number |
1Φ2W+G | ||||||||
|
Voltage |
low-end |
0~150V (L-N) | ||||||||
|
high-end |
0~300V(L-N) | |||||||||
|
frequency |
45-70Hz, 50Hz, 60Hz, 400Hz, 2F (2nd harmonic), 4F (4th harmonic) | |||||||||
|
40-500Hz (option) | ||||||||||
|
Maximum current |
low-end |
375A |
500A |
834A |
1000A |
1250A |
1500A |
1667A |
2500A | |
|
high-end |
188A |
250A |
417A |
500A |
625A |
750A |
834A |
1250A | ||
|
Frequency stability |
≤0.01% | |||||||||
| ,
load regulation |
± 0.5% (linear load) | |||||||||
|
Waveform Distortion (THD) |
1.5% (linear load) | |||||||||
|
reaction time |
Maximum value 2ms | |||||||||
|
Instructions/Resolution |
4-digit frequency table |
Resolution 0.1Hz | ||||||||
|
4-digit voltmeter |
Resolution 0.1V | |||||||||
|
4-digit ammeter |
Resolution below 4A 0.001A; Resolution above 4A 0.01A | |||||||||
|
4-digit wattmeter |
Resolution below 200W: 0.1W; Resolution above 200W: 1W | |||||||||
|
protective device |
Input/output no fuse switch, electronic circuit quickly detects overvoltage, overcurrent, overload | |||||||||
|
High temperature and short circuit automatic tripping protection and alarm device | ||||||||||
|
Insulation reactance |
DC500V20M Ω or above | |||||||||
|
voltage-resistant insulation |
AC1800V/5mA/1 minute | |||||||||
|
Cooling device |
Forced fan cooling | |||||||||
|
environment |
Operating Temperature |
0℃~50℃ | ||||||||
|
relative humidity |
0-90% (non condensing state) | |||||||||
|
altitude |
1500m | |||||||||
|
Dimensions (width x depth x height) mm |
700×1020×1205 |
800×1450×1205 |
1000×1600×1450 | |||||||
|
Net weight (kg) |
four hundred and twenty |
five hundred and sixty |
nine hundred and sixty |
one thousand one hundred and fifty |
one thousand four hundred and fifty |
one thousand and eight hundred |
one thousand and nine hundred |
two thousand eight hundred and fifty | ||
| Note: The maximum power of this series is single-phase 300KVA, with a maximum output frequency of 1000Hz and a maximum output voltage of 1000V; | ||||||||||
| F=input power frequency, when the input frequency is 50Hz, 2F output frequency=2x input frequency=2x50Hz=100Hz; | ||||||||||
| Specially made according to customer requirements for specifications; | ||||||||||
| Our company continuously develops and improves specifications, and changes are subject to change without prior notice. For detailed information, please consult our business. | ||||||||||