| Product name: | 3KVA~800KVA series three-phase variable frequency power supply | ||||||
| specification: | ![]() |
||||||
| Category: | transformer equipment -- Variable Frequency Power Supply | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| Technical parameters for 3KVA to 120KVA | ||||||||||||
|
model |
thirteen thousand and three |
thirteen thousand and six |
thirty-three thousand and ten |
thirty-three thousand and fifteen |
thirty-three thousand and twenty |
thirty-three thousand and thirty |
thirty-three thousand and forty-five |
thirty-three thousand and sixty |
thirty-three thousand and one hundred |
thirty-three thousand one hundred and twenty | ||
|
Total output capacity |
3KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
120KVA | ||
|
Output capacity of each phase |
1KVA |
2KVA |
3.3KVA |
5KVA |
6.7KVA |
10KVA |
15KVA |
20KVA |
33KVA |
40KVA | ||
|
Circuit method |
IGBT/SPWM Sine Pulse Width Modulation Method | |||||||||||
|
Input (communication) |
phase number |
1Φ2W+G |
3Φ4W+G | |||||||||
|
Voltage |
220V±10% |
380V±10% | ||||||||||
|
frequency |
50Hz±3HZ/60Hz±3Hz | |||||||||||
|
Output (communication) |
phase number |
3Φ4W+G | ||||||||||
|
Voltage |
low-end |
Phase voltage: 0-150V (L-N)/Line voltage: 0-260V (L-L) | ||||||||||
|
high-end |
Phase voltage: 0-300V (L-N)/Line voltage: 0-520V (L-L) | |||||||||||
|
frequency |
45-70Hz, 50Hz, 60Hz, 400Hz, 2F (2nd harmonic), 4F (4th harmonic) | |||||||||||
|
40-500Hz (option) | ||||||||||||
|
Maximum current per phase |
low-end |
8.4A |
16.8A |
28A |
42A |
50A |
84A |
125A |
168A |
276A |
336A | |
|
high-end |
4.2A |
8.4A |
14A |
21A |
25A |
42A |
63A |
84A |
138A |
168A | ||
|
Frequency stability |
≤0.01% | |||||||||||
|
load regulation |
± 0.5% (linear load) | |||||||||||
|
Waveform Distortion (THD) |
1.5% (linear load) | |||||||||||
|
reaction time |
Maximum value 2ms | |||||||||||
|
Instructions/Resolution |
4-digit frequency table |
Resolution 0.1Hz | ||||||||||
|
4-digit voltmeter |
Resolution 0.1V | |||||||||||
|
4-digit ammeter |
Resolution below 4A 0.001A; Resolution above 4A 0.01A | |||||||||||
|
4-digit wattmeter |
Resolution below 200W: 0.1W; Resolution above 200W: 1W | |||||||||||
|
protective device |
Input/output no fuse switch, electronic circuit quickly detects overvoltage, overcurrent, overload | |||||||||||
|
High temperature short circuit and automatic tripping protection and alarm device | ||||||||||||
|
Insulation reactance |
DC500V20M Ω or above | |||||||||||
|
voltage-resistant insulation |
AC1800V/5mA/1 minute | |||||||||||
|
Cooling device |
Forced fan cooling | |||||||||||
|
environment |
Operating Temperature |
0℃~50℃ | ||||||||||
|
relative humidity |
0-90% (non condensing state) | |||||||||||
|
altitude |
1500m | |||||||||||
|
Dimensions (width x depth x height) mm |
430×650×650 |
610×950×725 |
700×1340×1280 |
700×1340×1280 |
800×1340×1420 | |||||||
|
Net weight (kg) |
ninety-two |
one hundred and twenty-five |
one hundred and eighty |
two hundred and forty-five |
three hundred and sixty |
four hundred |
five hundred and fifty |
six hundred and fifty |
one thousand and fifty |
one thousand two hundred and fifty | ||
| Note: The maximum power of this series is three-phase 800KVA, with a maximum output frequency of 1000Hz and a maximum output voltage of 1000V; | ||||||||||||
| F=input power frequency, when the input frequency is 50Hz, 2F output frequency=2x input frequency=2x50Hz=100Hz; | ||||||||||||
| Specially made according to customer requirements for specifications; | ||||||||||||
| Our company continuously develops and improves specifications, and changes are subject to change without prior notice. For detailed information, please consult our business. | ||||||||||||
| Technical parameters for 150KVA to 800KVA | |||||||||
|
model |
thirty-three thousand one hundred and fifty |
thirty-three thousand and two hundred |
thirty-three thousand and three hundred |
thirty-three thousand and four hundred |
thirty-three thousand and five hundred |
thirty-three thousand and six hundred |
thirty-three thousand and eight hundred | ||
|
Total output capacity |
150KVA |
200KVA |
300KVA |
400KVA |
500KVA |
600KVA |
800KVA | ||
|
Output capacity of each phase |
50KVA |
67KVA |
100KVA |
134KVA |
167KVA |
200KVA |
267KVA | ||
|
Circuit method |
IGBT/SPWM Sine Pulse Width Modulation Method | ||||||||
|
Input (communication) |
phase number |
3Φ4W+G | |||||||
|
Voltage |
380V±10% | ||||||||
|
frequency |
50Hz±3HZ/60Hz±3Hz | ||||||||
|
Output (communication) |
phase number |
3Φ4W+G | |||||||
|
Voltage |
low-end |
Phase voltage: 0-150V (L-N)/Line voltage: 0-260V (L-L) | |||||||
|
high-end |
Phase voltage: 0-300V (L-N)/Line voltage: 0-520V (L-L) | ||||||||
|
frequency |
45-70Hz, 50Hz, 60Hz, 400Hz, 2F (2nd harmonic), 4F (4th harmonic) | ||||||||
|
40-500Hz (option) | |||||||||
|
Maximum current per phase |
low-end |
416A |
556A |
834A |
1112A |
1400A |
1667A |
2224A | |
|
high-end |
208A |
278A |
417A |
556A |
700A |
833A |
1112A | ||
|
Frequency stability |
≤0.01% | ||||||||
|
load regulation |
± 0.5% (linear load) | ||||||||
|
Waveform Distortion (THD) |
1.5% (linear load) | ||||||||
|
reaction time |
Maximum value 2ms | ||||||||
|
Instructions/Resolution |
4-digit frequency table |
Resolution 0.1Hz |
Can switch between displaying parameters of A, B, and C phases at will | ||||||
|
4-digit voltmeter |
Resolution 0.1V | ||||||||
|
4-digit ammeter |
Resolution below 4A 0.001A; Resolution above 4A 0.01A | ||||||||
|
4-digit wattmeter |
Resolution below 200W: 0.1W; Resolution above 200W: 1W | ||||||||
|
protective device |
Input/output no fuse switch, electronic circuit quickly detects overvoltage, overcurrent, overload | ||||||||
|
Insulation reactance |
DC500V20M Ω or above | ||||||||
|
voltage-resistant insulation |
AC1800V/5mA/1 minute | ||||||||
|
Cooling device |
Forced fan cooling | ||||||||
|
environment |
Operating Temperature |
0℃~50℃ | |||||||
|
relative humidity |
0-90% (non condensing state) | ||||||||
|
altitude |
1500m | ||||||||
|
Dimensions (width x depth x height) mm |
950×1500×1800 |
(850×1200×1020)×3 |
(850×1200×1600)×3 |
(900×1400×1600)×3 | |||||
|
Net weight (kg) |
one thousand three hundred and fifty |
two thousand and fifty |
three thousand and fifty |
four thousand and fifty |
five thousand and six hundred |
six thousand and three hundred |
seven thousand and eight hundred | ||
| Note: The maximum power of this series is three-phase 800KVA, with a maximum output frequency of 1000Hz and a maximum output voltage of 1000V; | |||||||||
| F=input power frequency, when the input frequency is 50Hz, 2F output frequency=2x input frequency=2x50Hz=100Hz; | |||||||||
| Specially made according to customer requirements for specifications; | |||||||||