HomeYour location:Homeinstrumentation and metersRecording instrumentBalance recorder → DR series data logger
Column tabs 
Product name: DR series data logger
specification: DR series data logger
  Zoom Zoom in on the image
Category: instrumentation and meters -- Balance recorder
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


DR series data loggerDetailed product description:Column tabs
The DR series data recorder (temperature circuit recorder, hereinafter referred to as data recorder) is a circuit detection recorder that inputs analog signals such as temperature and DC voltage, and records data at specified time intervals. The data logger is divided into two types: integrated and separated. The integrated type has three measurement points: 30 points, 20 points, and 15 points; The separated type consists of a main body and a terminal box. The main body box has a handle that can be carried or used for embedding. The maximum number of measurement points can reach 210, with a total of 5 types.
8 or 9 measurement ranges, 5 thermocouples (S, K, J, E, T), 3 DC voltages (+20mV,+50mV,+5V), and Pt100 temperature measuring resistors
Can be divided into 8 groups for recording
High precision ± 0.1%
Alarm printing function
Dual use for carrying and embedding, hole size: 274 X 145 (mm)
Deviation calculation function

DR series data logger model specifications
·Integrated type

model

Measurement points

Measurement range

DR030

30 o'clock

S. K, E, J, T thermocouple wires and 5 types including ± 20mV, ± 50mV, ± 5mV, etc

DR020R

eight p.m.

In addition to the above, there are a total of 9 types of Pt100 Ω temperature measuring resistors


·Separate terminal box (measuring points 30-210)

model

Measurement channel

Number of input points

Measurement range

DX-TB1T

001~030ch. Used

30 o'clock

S. K, E, J, T thermocouples

And ± 20mV, ± 50mV

8 types of ± 5V in total

DX-TB2T

031~060ch. Used

30 o'clock

DX-TB3T

061-090ch. Used

30 o'clock

DX-TB4T

091-120ch. Used

30 o'clock

DX-TB5T

121-150ch. Used

30 o'clock

DX-TB6T

151~180ch. Used

30 o'clock

DX-TB7T

181~210ch. Used

30 o'clock


·Separated body (with 90 and 210 measurement points)

model

Measurement points

Number of terminal boxes

DR090L

Maximum 90 points

External terminal box, capable of connecting 3 units

DR210L

Maximum 210 points

External terminal box, capable of connecting up to 7 units


·Separate terminal box (measuring points 20-140)

model

Measurement channel

Number of input points

Measurement range

DX-TB1R

001 ~ 030ch.

eight p.m.

S. K, E, J, T thermocouples

And ± 20mV, ± 50mV

± 5V and Pt100 thermoelectric

There are a total of 9 types of obstacles

DX-TB2R

031 ~ 060ch.

eight p.m.

DX-TB3R

061 ~ 090ch.

eight p.m.

DX-TB4R

091 ~ 120ch.

eight p.m.

DX-TB5R

121 ~ 150ch.

eight p.m.

DX-TB6R

151 ~ 180ch.

eight p.m.

DX-TB7R

181 ~ 210ch.

eight p.m.


·Separate main body and terminal box matching (measuring points 20-90) with 1m long dedicated wire

Subject

Terminal box

DR090L

Measurement range

Measurement points

eight p.m.

30 o'clock

40 points

50 points

60 points

70 points

80 points

90 points

S. K, E, J, T thermocouples

± 20mV, ± 50mV, ± 5mV

There are a total of 8 types

——

DX-TB1T

——

DX-TB1T

DX-TB1T

DX-TB2T

Or * 2

DX-TB1R

DX-TB2R

DX-TB3R

*3

DX-TB1T

DX-TB1T

DX-TB1T

DX-TB1T

DX-TB2T

DX-TB3T

In addition to the above, plus

There are a total of 9 types of Pt100 thermal resistors

DX-TB1R

——

*1

DX-TB1R

DX-TB2R

DX-TB2R

DX-TB2R

DX-TB3R

DX-TB3R

——


Note: Channel numbers 1 to 20 and 31 to 50. *The channel numbers are No.1 to 20, 31 to 50, and 61 to 80. *The channel numbers are No.1 to 30, 31 to 50, and 61 to 80.