Test function |
measurement parameters |
time-consuming |
Remark |
|
Steady state testing |
Voltage (U: V), current (I: A), active power (P: W), power factor (PF), apparent power (S: VA), reactive power (Q: Var), active energy (Ep: W · h), reactive energy (Eq: Var · h) |
1 second/time |
|
|
Waveform |
All waveforms, voltage waveform, current waveform, phase separation waveform, waveform data: voltage modulation rate, voltage peak Upk, voltage peak coefficient Ucf, voltage distortion rate, current peak Ipk, current peak coefficient Icf | ||
|
Harmonics |
Voltage total harmonic (waveform distortion rate), current total harmonic; Harmonic bar chart, voltage deviation coefficient,
Voltage and current harmonics (frequency 1-59, intermediate frequency 1-29); Telephone harmonic factor (power frequency) | ||
|
unbalance degree |
Voltage imbalance, fundamental data of three-phase voltage, zero sequence voltage, negative sequence voltage, positive sequence voltage;
Voltage angle, current angle, phase angle; Phasor diagram | ||
|
Setting test |
Voltage setting rise range, relative voltage setting rise range;
Voltage setting drop range, relative voltage setting drop range;
Frequency setting rise range, relative frequency setting rise range;
Frequency setting decrease range, relative frequency setting decrease range; |
100 seconds |
Simultaneously conduct three-phase and average value tests |
|
Wave testing |
Maximum and minimum fluctuation voltage, steady-state voltage deviation;
Maximum and minimum fluctuation frequencies, steady-state frequency band |
60 seconds | |
|
Sudden testing
(Loading) |
The minimum instantaneous voltage that decreases during loading, transient voltage deviation, and voltage recovery time after increasing the load;
The lowest instantaneous frequency that decreases during loading, the transient frequency deviation, and the frequency recovery time after increasing the load; |
12 seconds
(Power frequency)
6 seconds
(Mid frequency) | |
|
Sudden unloading test
(Load reduction) |
The highest instantaneous voltage that rises during unloading, transient voltage deviation, and voltage recovery time after load reduction;
The highest instantaneous frequency that rises during unloading, transient frequency deviation, and frequency recovery time after load reduction; | ||
|
Recording waves |
Three phase voltage waveform; Four recording modes: Umod (peak to peak value, 256 points), 2000 points/second, 4000 points/second, Har (harmonic mode, power frequency 128 points/cycle, intermediate frequency 64 points/cycle); |
Record 28160 points per phase |
Three identical
Time recording wave |
Please refer to the relevant chapters in the manual for detailed information on each parameter item, and provide a detailed introduction for each.