F317/F319 Digital Clamp Type TableDetailed product description:Column tabs

F317/F319 digital clamp type table

Fluke 317/319 Clamp Type Table

Technical Specifications
Digital frequency display
6000 word resolution
Low battery indicator
Low battery indicator
power supply
3 AAA IEC LR03 batteries
Jaw opening
1.45 in (37 mm)
Clamp opening degree
1.45 in (37 mm)
Size (length X width X height) 6.39 in x 2.29 in x 1.20 in
(162.4 mm x 58.25 mm x 30.5 mm)
weight
384g (including battery)
Auto Range
Ohms
safety CE
EN/IEC 61010-1 and IEC 61010-2-032
Installation category III, 600V working environment


317 Technical Indicators
alternating current
range 40.00 A, 600.0 A
resolution 0.01 A, 0.1 A
accuracy 1.6% ± 6 words (50-60 Hz) {40A}
2.5% ± 8 words (60-500 Hz) {40A}
1.5% ± 5 words (50-60 Hz) {600 A}
2.5% ± 5 words (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A
Communication response valid value
direct current Range 40.00 A, 600.0 A
Resolution 0.01 A, 0.1 A
Accuracy 1.6% ± 6 words (40 A)
1.5% ± 5 words (600 A)
AC voltage
range 600.0 V
resolution 0.1 V
accuracy 1.5% ± 5 words (20-500Hz)
Communication response Effective Straight
DC voltage
range 600.0 V
resolution 0.1 V
accuracy 1% ± 4 words
resolution Range 400.0 Ω, 4000 Ω
Resolution 0.1 Ω, 1 Ω
Accuracy of 1% ± 5 words
On-off measurement
≤ 30 Ω
starting current
response time not conform to
frequency measurement
range not conform to
accuracy not conform to
trigger level not conform to


319 Technical Indicators
alternating current Range: 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ± 6 words (50-60 Hz) {40A}
2.5% ± 8 words (60-500 Hz) {40A}
1.5% ± 5 words (50-60 Hz) {600/1000 A}
2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
Effective value of communication response
direct current Range: 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ± 6 words (40 A) 1.5% ± 5 words (600/1000 A)
AC voltage Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 words (20-500Hz)
Effective and direct communication response
DC voltage
range 600.0 V
resolution 0.1 V
accuracy 1% ± 4 words
resolution Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy of 1% ± 5 words
On-off measurement
≤ 30 Ω
starting current
response time 100 milliseconds
frequency measurement Range 5.0-500.0 Hz
Accuracy 0.5% ± 5 words
Trigger level 10-100 Hz ≥ 5 A, 5-10 Hz, 100-500 Hz ≥ 10 A


All accuracy indicators refer to 73 ° F ± 41 ° F (23 ° C ± 5 ° C)

Below 64 ° F and above 82 ° F (18 ° C and above 28 ° C)

Environmental parameters:
Operating Temperature
14°F to 122°F (-10 °C to 50 °C)
Storage temperature
-40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity
No fog (<50 ° F) (<10 ° C)
90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
No fog
Working altitude
2000 meters above sea level
Storage altitude
12000 meters above sea level
IP indicators
IP40
Vibration requirements
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements
one meter
EMI, RFI, EMC
Non specific to EMC environment usage ≥ 0.1 V/m
temperature coefficient 0.1x (specified accuracy)/° C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)


F317/F319 digital clamp type table