HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer27.5KV current transformer → LZZBJ-27.5(GYW1) type current transformer
Column tabs 
Product name: LZZBJ-27.5(GYW1) type current transformer
specification: LZZBJ-27.5(GYW1) type current transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 27.5KV current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


LZZBJ-27.5(GYW1) type current transformerDetailed product description:Column tabs
LZZBJ-27.5 (GYW1) current transformer is suitable for areas with an altitude of 1000m and below, and high-altitude products are suitable for areas with an altitude of 2500m and below. It is used for precision electrical measurement and relay protection in power systems with a frequency of 50Hz and a maximum operating voltage of 40.5kV.
Environmental temperature: The normal type is+40 ℃~-15 ℃; The plateau type ranges from+25 ℃ to -15 ℃.
Product type: Indoor.
Atmospheric conditions: There is no pollution or explosive medium in the installation site that seriously affects the insulation of the transformer.
The installation site has no severe vibrations or bumps.
Open circuit is not allowed during product operation, otherwise there is a high voltage hazard.
The temperature during transportation and storage ranges from+40 ℃ to -15 ℃.

Technical parameters of LZZBJ-27.5 (GYW1) current transformer

Product execution standard: GB1208-1997 "Current Transformers".
Rated secondary current: 5A and 1A.
Instrument security factor: 0.2S level FS ≤ 5; Level 0.2 and 0.5 FS ≤ 10.
Insulation and heat resistance grade: Grade E.
Secondary structure: two coils, three coils, four coils.
The rated secondary lower limit load is 25% of the rated secondary load.
The rated primary current value, rated secondary load, accurate limit coefficient, rated short-time current value, level combination, and weight are listed in the following table. Please consult with the manufacturer for special specification products.

insulation level
Ordinary type: 40.5/95/185kV
Plateau type: 40.5/110/226 kV (below 2500m)
accuracy level
0.2S、0.2、0.5、
5P、10P
Partial discharge capacity
The applied voltage is 80% of the power frequency withstand voltage, and after 60 seconds, it drops to the measured voltage of 28 kV with a discharge capacity of ≤ 20pC.
rated
once
current
(A)
Rated secondary load (VA) COS φ=0.8
5P and 10P level standards
Limit coefficient
1S short-term
Thermal current
(kA)
Dynamic stability
current
(kA)
0.2S
zero point two
zero point five
5P、10P
1A
5A
1A
5A
1A
5A
1A
5A
1A
5A
twenty
ten
thirty
ten
thirty
ten
thirty
thirty
fifty
ten
ten
two point five
six point three
thirty
four point five
twelve
forty
six point three
sixteen
fifty
eight
twenty
seventy-five
twelve point five
thirty-one point five
one hundred
twenty-two point five
fifty
one hundred and fifty
twenty-five
sixty-three
two hundred
thirty-one point five
eighty
300~500
forty-five
one hundred and ten
600~1500
sixty-three
one hundred and thirty


1. Two coils: Appearance: 405 × 300 × 550 (length × width × height), Level combination: 0.2S/0.2S; 0.2S/5P。
2. Three coils: Appearance: 420 × 300 × 550 (length × width × height), Level combination: 0.2S/0.2S/0.2S; 0.2S/0.2S/5P。
3. Four coils: Appearance: 480 × 300 × 550 (length × width × height), Level combination: 0.2S/0.2S/0.2S/0.2S; 0.2S/0.2S/5P/5P。
4. The measurement levels are interchangeable, and special products with two coils can also be produced using three coil and four coil shapes.


LZZBJ-27.5 (GYW1) type current transformer

LZZBJ-27.5(GYW1) type current transformer
Product Category