HomeYour location:Homeinstrumentation and metersRecording instrumentBalance recorder → L Series Automatic Balance Small Record Adjustment Alarm Device
Column tabs 
Product name: L Series Automatic Balance Small Record Adjustment Alarm Device
specification: L Series Automatic Balance Small Record Adjustment Alarm Device
  Zoom Zoom in on the image
Category: instrumentation and meters -- Balance recorder
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


L Series Automatic Balance Small Record Adjustment Alarm DeviceDetailed product description:Column tabs
L series automatic balance small record adjustment and alarm device

The L series instruments are small recorders, recording regulators, and recording alarms manufactured using the latest electronic and mechanical technologies, with high quality and reliability.
Basic varieties have records and alarm devices for recording; The recording methods include single stroke, double stroke, triple stroke, and 6-point dot matrix; The adjustment methods include two position, three position, proportional position, and PID; There are upper limit (lower limit) and upper and lower limit alarm methods; The input types include mA, mV, thermocouple, thermistor, etc.
The characteristics of L series instruments are as follows:
Adopting the IEC recommended DIN standard with dimensions of 144mm '144mm, it has small volume, light weight, and easy handling.
• Compact and multifunctional
It has many excellent features such as recording amplitude of 100mm, accuracy of+0.5%, and full-scale alarm setting.
Using high reliability components with the goal of no maintenance required; Using sealed conductive plastic sliding line resistors, input converters with dry spring switches, and various highly reliable long-life components such as self-lubricating bearings.
Using printed scale plates for easy interchange of scales and easy inspection.
• Clear records
Using an inexpensive and convenient fiber recording pen, the recording is clear and continuous, making it easy to maintain.
• Rich and complete options
• Hole size: 138X138 (mm)

Model List

·Single pen (recorder, recording alarm, recording regulator) dotting type (recorder, recording alarm)

Record

method

model

Alarm method or

adjustment method

Input signal

mA

mV

thermocouple

Resistance Thermometer

single transaction

recorder

EL900-01

EL800-01

EL100-01

EL200-01

Record alarm device

Upper or lower limit formula

EL926-01

EL826-01

EL126-01

EL226-01

Upper and lower limit formula

EL936-01

EL 836-01

EL136-01

EL236-01

Record regulator

2-position type

EL921-01

EL821-01

EL121-01

EL221-01

3-position type

EL932-01

EL832-01

EL132-01

EL232-01

Proportional position formula

EL941-01

EL841-01

EL141-01

EL241-01

P

I

D

formula

Switch pulse type

EL961-01

EL861-01

EL161-01

EL261-01

Switch servo type

EL962-01

EL862-01

EL162-01

EL262-01

Current input type

EL963-01

EL863-01

EL163-01

EL263-01

Dot style

six o'clock

recorder

EL900-06

EL800-06

EL100-06

EL200-01

Record alarm device

Upper or lower limit formula

EL926-06

EL826-06

EL126-06

EL226-01

Upper and lower limit formula

EL936-06

EL836-06

EL136-06

EL236-01


Note: For densely installed recorders, add M after the model number. For example, EL900-06M

·Two pens (recorder, recording alarm)

Record

method

model

The first function

The second function

record

Upper or lower limit alarm

Upper and lower limit alarm

Two strokes

recorder

Record

FL □□ 00

Record alarm device

Record

FL □□ 06

FL □□ 07

Upper or lower limit alarm

FL □□ 66

Upper and lower limit alarm

FL □□ 77


Note: Fill in the input signals of each pen in □□, in order of the first pen and the second pen. MA input is 9, mV input is 8, thermocouple input is 1, and thermistor input is. (Example: First mV input, second input)
The recorder for thermocouple input is FL8100.
Add M at the end of the model for densely installed recorders. For example: FL8100M.

·Three pens (recorder, recording alarm)

Record

method

model

The first function

The second function

The third function

record

Upper or lower limit alarm

Upper and lower limit alarm

Three strokes

recorder

Record

Record

GL □□□ 000

Record alarm device

Record

Record

GL □□□ 006

GL □□□ 007

Record

Upper or lower limit alarm

GL □□□ 066

Record

Upper and lower limit alarm

GL □□□ 077

Upper or lower limit alarm

Upper or lower limit alarm

GL □□□ 666

Upper and lower limit alarm

Upper and lower limit alarm

GL □□□ 777


Note: Fill in the input signals of each pen in the order of the first pen, second pen, and third pen. MA input is 9, mV input is 8, thermocouple input is 1, and thermistor input is 2. (Example: 1st pen)
The recorder for mV input, second thermocouple input, and third thermistor input is GL812000.
Add M at the end of the model for densely installed recorders. For example: GL812000M.

L Series Automatic Balance Small Record Adjustment Alarm Device
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference