HomeYour location:Homeinstrumentation and metersRecording instrumentBalance recorder → H series automatic balance recorder (adjustable alarm)
Column tabs 
Product name: H series automatic balance recorder (adjustable alarm)
specification: H series automatic balance recorder (adjustable alarm)
  Zoom Zoom in on the image
Category: instrumentation and meters -- Balance recorder
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


H series automatic balance recorder (adjustable alarm)Detailed product description:Column tabs
The H series automatic balance recording (adjustment, alarm) instrument has over 900 models available for selection in various combinations The recording methods include single stroke, double stroke, triple stroke pen writing, and line typing from 6 to 12 o'clock and 24 o'clock; There are two adjustment methods: 2-position, 3-position, and PID; There are upper limit, lower limit, and upper and lower limit alarm methods. By combining these, high-quality recorders that users are eagerly anticipating can be provided.

High precision: The accuracy of industrial recorders is+0.5%
• Long lifespan: High resolution, long-lasting balanced sliding line resistors
• High reliability: good sealing, high reliability input switch
• Clear recording: Apply critical damping to record the curve clearly
• Hole size: 281X281 (mm)

Model List
·Single pen (recorder, recording alarm device) dot type (recorder, recording alarm device, recording adjustment device)

Recording method

model

Alarm method or

adjustment method

input signal

Enter points (note)

mA

mV

thermocouple

Resistance Thermometer

single transaction

recorder

EH900 — 01

EH800 — 01

EH100 — 01

EH200 — 01

Combination of submerged thermocouples

Δ Steel Melting Temperature Recorder

EH600 — 01

Combination with radiation thermometer

Δ Radiation Temperature Recorder

EH700 — 01

Record alarm device

Upper or lower limit formula

EH926 — 01

EH826 — 01

EH126 — 01

EH226 — 01

Upper and lower limit formula

EH936 — 01

EH836 — 01

EH136 — 01

EH236 — 01

Record regulator

2-position type

EH921 — 01

EH821 — 01

EH121 — 01

EH221 — 01

3-position type

EH932 — 01

EH832 — 01

EH132 — 01

EH232 — 01

P

I

D

formula

Intermittent pulse shape

EH961 — 01

EH861 — 01

EH161 — 01

EH261 — 01

Intermittent servo shape

EH962 — 01

EH862 — 01

EH162 — 01

EH262 — 01

Current output shape

EH963 — 01

EH863 — 01

EH163 — 01

EH263 — 01

Find some style

recorder

EH900 —□

EH800 —□

EH100 —□

EH200 —□

6:00, 12:00, 24:00

Δ Radiation Temperature Recorder

EH700 —□

six o'clock

Record

Alarm meter

Multiple common settings

Joint regulation

Up and down or lower limit formula

EH926 —□

EH826 —□

EH126 —□

EH226 —□

6:00, 12:00, 24:00

Upper and lower limit formula

EH936 —□

EH936 —□

EH136 —□

EH236 —□

6:00, 12:00, 24:00

Multiple individual settings

Individual adjustment

Upper or lower limit formula

EH928 —□

EH928 —□

EH128 —□

EH228 —□

6 o'clock, 12 o'clock*

Upper and lower limit formula

EH938 —□

EH938 —□

EH138 —□

EH238 —□

6 o'clock *, 12 o'clock*

Record

Regulator

Multiple common settings

Individual adjustment

2-position type

EH921 —□

EH921 —□

EH121 —□

EH221 —□

6 o'clock, 12 o'clock*

Multiple individual settings

Individual adjustment

2-position type

EH927 —□

EH927 —□

EH127 —□

EH227 —□

6 o'clock, 12 o'clock*

3-position type

EH937 —□

EH937 —□

EH137 —□

EH237 —□

6 o'clock *, 12 o'clock*


Fill in the input points, and when entering points 6, 12, and 24, fill in 2, 12, and 24 respectively. (Example: mV input, 6-point recorder is EH800-06)
*As an additional alarm unit or adjustment unit for the host (width 288 x high difficulty 44 x depth 370mm)
As a special specification, it should be negotiated before ordering.

·Dual pen (recorder, recording alarm, recording regulator)

Recording method

model

The first function

The second function

Record

Upper or lower limit alarm

Upper and lower limit alarm

2-position adjustment

3-position adjustment

PID type intermittent pulse shape

PID intermittent servo form

PID type current output form

Double Pen

recorder

Record

FH □□ 00

——

——

——

——

——

——

——

Record alarm device

Record

——

FH □□ 06

FH □□ 07

——

——

——

——

——

Upper or lower limit alarm

——

FH □□ 66

——

——

——

——

——

——

Upper and lower limit alarm

——

——

FH □□ 77

——

——

——

——

——

Record regulator

Record

——

——

—— +

FH □□ 04

FH □□ 05

FH □□ 01

FH □□ 02

FH □□ 03

Record and adjust the alarm device

Upper or lower limit alarm

——

——

——

FH □□ 64

FH □□ 65

FH □□ 61

FH □□ 62

FH □□ 63

Upper and lower limit alarm

——

——

——

FH □□ 74

FH □□ 75

FH □□ 71

FH □□ 72

FH □□ 73


□□ Fill in the input signals of each pen, in order. For the first and second pens, the mV input is 8, the thermistor input is 2, and the mA input is 9.
(Example: The recorder for the first mV input and the second thermocouple input is FH8100)

·Three pens (recorder, recording alarm)

Recording method

model

The first function

The second function

The third function

Record

Upper and lower limit alarm

Upper and lower limit alarm

Three strokes

Record

Record

Record

GH □□□ 000

——

——

Record alarm device

Record

Record

——

GH □□□ 006

GH □□□ 007

Record

Upper or lower limit alarm

——

GH □□□ 066

——

Record

Upper and lower limit alarm

——

——

GH □□□ 077


□□□ Fill in the input signals of each pen in the order of the first pen, the second pen, and the third pen. The mV input is 8, the thermocouple input is 1, the thermistor input is 2, and the mA input is 9.
(Example: The recorder for the first mV input, the second thermocouple input, and the third thermistor input is GH812000)

H series automatic balance recorder (adjustable alarm)
H series automatic balance recorder (adjustable alarm)