The T1000 integrated temperature transmitter integrates temperature sensing elements (thermistor or thermocouple) with signal conversion and amplification units to measure the temperature of liquids, vapors, and other gas media or solid surfaces within the range of -200~1600 ℃ in various process flows. It is usually used in conjunction with display instruments, recording instruments, and various control systems.
The T1000 integrated temperature transmitter has the following characteristics: DC24V power supply, two-wire system, direct output of standard 4-20mA signal, high accuracy, anti-interference, good long-term stability, maintenance free, and remote transmission (up to 1000 meters). This series of products is divided into two types: ordinary and explosion-proof, and has been widely used in various industrial control fields.
Technical specifications of T1000 integrated temperature transmitter
Technical parameters
Optional input: Two wire or three wire Pt100 thermistor temperature range -200~500 ℃
All known thermocouples K, E, B, S, etc.
Output: 4~20mA 1~5V (optional)
Fuse detection: (upper limit standard)
Linearity Pt100 better than 0.05% FS TC/mV better than 0.05% FS (referring to mV input)
Stability Pt100 (100%) Range 0.03FH/℃
TC/mV (25mV input) 0.05% FS/℃
TC cold end compensation: 0.05 ℃/℃
Power supply voltage: 2-38VDC
Maximum load: R=50 (U-12)
Environmental temperature: -40~70 ℃
Environmental humidity: 0~95% RH