HomeYour location:Homeinstrumentation and metersPressure gaugePressure transmitter → BP133 series pressure transmitter
Column tabs 
Product name: BP133 series pressure transmitter
specification: BP133 series pressure transmitter
  Zoom Zoom in on the image
Category: instrumentation and meters -- Pressure transmitter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


BP133 series pressure transmitterDetailed product description:Column tabs
Product Introduction

The BP133 series pressure transmitter adopts imported ceramic sensors, among which the BP133-A type uses a piezoresistive ceramic diaphragm, and the BP133-B type uses an E+H capacitive ceramic sensor, coupled with high-precision electronic components, assembled through strict process. Compared with conventional pressure transmitters on the current market There are two significant technological differences, one is that the measuring element uses emerging ceramic materials, which will not cause process pollution to the measuring medium The second is that there is no intermediate liquid inside the measuring element, which is completely fixed The medium pressure directly acts on the ceramic diaphragm, causing displacement of the measuring diaphragm and resulting in a change in capacitance. This change is detected, amplified, and converted into a standard signal output by the electronic components connected to it. Under normal pressure, the diaphragm is offset by 0.025mm; under overpressure, the diaphragm is offset by 0.1mm. At this time, the measuring diaphragm is attached to the ceramic bracket and protected to avoid damage

BP133 series BP133 series pressure transmitter product technical specifications

Main performance indicators:
1. Adopting imported ceramic sensors, without intermediate liquid, with small temperature drift and strong corrosion resistance; Durable and sturdy, with strong resistance to overvoltage and excellent wear and impact resistance.
2. Pure ceramic substrate will not cause process pollution and is suitable for the food and pharmaceutical industries
Zero point, adjustable range with positive and negative transfer, easy to operate, and does not affect each other during adjustment;
4. Wide pressure range, from a slight pressure of 10kPa to a high pressure of 160MPa;
5. Good stability: ≤ 0.2% FS/year;
6. Linearity better than 0.1% FS;
7. Wide compensation temperature range: -40 to+85 ℃;
8. Anti electromagnetic interference;
Due to the use of dry ceramics and the absence of any dielectric, the sensor is minimally affected by temperature and is not affected by installation direction.
10 intrinsically safe explosion-proof, explosion-proof grade iaIICT4;
1L shell protection level: IP65
The variety of two-wire 4-20mA output has a standard power supply of DC24V. When the load resistance is greater than 600 Ω, an additional 1V power supply is required for every 50 Ω increase, but the maximum power supply limit is DC45V. When more than DC24V power supply is needed, the output circuit should avoid long-term operation in a zero load resistance state. If necessary, a resistor can be connected in series in the output circuit to reduce the power consumption of the output power transistor Minimum supply voltage DC12V at zero load resistance

Main technical parameters:

Scope of application
Measurement of Pressure in Industrial Process Control Systems
measured medium
Various media compatible with ceramics
Range (gauge pressure, absolute pressure)
0~10kPa,0~16kPa,0~25kPa,0~40kPa,
0~0.06MPa,0~0.1MPa,0~0.16MPa,
0~0.25MPa,0~0.4MPa,0~0.6MPa,
0~1MPa,0~1.6MPa,0~2.5MPa,
0~4MPa,0~6MPa,0~10MPa,
0~16MPa,0~25MPa,0~40MPa,
0~60MPa,0~100MPa,0~160MPa
overload
For measuring range ≤ 10MPa, double;
For ranges greater than 10MPa, 1.5 times
Accuracy (including linearity, hysteresis, repeatability)
0.25%,0.5%
Working temperature range
Tested medium: -60 to+150 ℃;
Environmental temperature: -40 to+85 ℃
Compensation temperature range
-40~+85℃
The impact of environmental temperature changes
For ranges greater than 0.06MPa:
For 0.25 level:<0.01%/℃;
For level 0.5:<0.02%/℃;
2. For ranges ≤ 0.06MPa:
For 0.25 level:<0.02%/℃;
For level 0.5:<0.04%/℃
stability
<0.2% FS/year
output
4-20mADC two-wire system
power supply
12-45VDC (considering load);
*Corresponding safety barriers are required for intrinsically safe systems
electrical interface
M20 × 1.5 or ZG1/2
Process connector
M20 × 1.5 or 1/2 NPT, or according to user requirements
power consumption
<1W
Shell protection level
IP65
weight
<1.5kg

Type spectrum Explanation
model BP208 Pressure transmitter
sensor type A Dry thick film piezoresistive ceramic sensor
B Dry thick film capacitive ceramic sensor
measurement range A 0-5kPa~20KPa
B 0-20kPa~70KPa
C 0-70kPa~350KPa
D 0-200kPa~700KPa
E 0-700kPa~3.5MPa
F 0-2.0MPa~7MPa
G 0-7MPa~35KPa
H 0-20MPa~120MPa
accuracy class 0.1%
0.25%
0.5%
output signal E 4-20mA DC two-wire system
K 1-5V DC three wire system
M User agreement
Pressure connection R Standard type (M20 × 1.5)
P Qi Ping Membrane
O Process according to user size
other options i Intrinsic safety type ia Ⅱ CT6
d Explosion proof type DIIBT4
T Marine type
M1 Linear indicator table
M2 Digital LCD indicator
M3 Digital tube digital indicator
Z With damping adjustment
Q migration
A Absolute pressure measurement
F Negative pressure measurement
S Radiators and process connectors
Y User agreement

BP133 series pressure transmitter
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference